Packaged unit
Operation Manual
AP42NACAAA
AM
AU42NAIAAA
(HPU-44H03)
TEMP
ON
OFF
SWING
FAN
SET TEMP
AM
PM
TIMER
CLOCK
SET
TIME
TIME
:
TEMP
TEMP
MODE
TIMER ON
AM
PM
TIMER OFF
AM
PM
C
ON
OFF
:
ROOM TEMP
Ion
A
U
T
L
O
M
E
D
H
I
SLEEP
FAN SPEED
:
O
SWING
AP42NACMAA
AU42NAIMCA
(HPU-42C03)
MODE
CLOCK
SLEEP
SET
TIMER
LOCK RESET
No.0010571223
Download from Www.Somanuals.com. All Manuals Search And Download.
CAUTIONS
All these valuable materials may be taken
to a waste collecting center and used again
after adequate recycling.
Disposal of the old air conditioner
Before disposing an old air conditioner
that goes out of use, please make sure
it's inoperative and safe. Unplug the air
conditioner in order to avoid the risk of
child entrapment.
Consult your local authorities for the name
and address of the waste materials
colle cting ce nte rs a nd wa s te pa pe r
disposal services nearest to your house.
It must be noticed that air conditioner
system contains refrigerants, which
require specialized waste disposal. The
valuable materials contained in a air
conditioner can be recycled. Contact
your local waste disposal center for
proper disposal of an old air conditioner
and contact your local authority or your
dealer if you have any question. Please
ensure that the pipework of your air
conditioner does not get damaged prior
to being picked up by the relevant
waste disposal center, and contribute
to e nvironme nta l a wa re ne s s by
ins is ting on a n a ppropria te , a nti-
pollution method of disposal.
Safety Instructions and Warnings
Before starting the air conditioner, read
the information given in the User's Guide
carefully. The User's Guide contains very
important observations relating to the
assembly, operation and maintenance of
the air conditioner.
The ma nufa cture r doe s not a cce pt
responsibility for any damages that may
a ris e due to non-obs e rva tion of the
following instruction.
Damaged air conditioners are not to
be put into operation. In case of doubt,
consult your supplier.
Disposal of the packaging of your
new air conditioner
Use of the air conditioner is to be
carried out in strict compliance with the
relative instructions set forth in the User's
Guide.
All the packaging materials employed
in the pa cka ge of your ne w a ir
conditioner may be disposed without
any danger to the environment.
Installation shall be done by professional
people, don't install unit by yourself.
The cardboard box may be broken or
cut into smaller pieces and given to a
waste paper disposal service. The
wrapping bag made of polyethylene
a nd the polye thyle ne foa m pa ds
contain no fluorochloric hydrocarbon.
1
Download from Www.Somanuals.com. All Manuals Search And Download.
CAUTIONS
For the purpose of safety, the air
conditioner must be properly grounded
in accordance with specifications.
Specifications
The refrigerating circuit is leak-proof.
Always remember to unplug the air
conditioner before opening inlet grill.
Never unplug your air conditioner by
pulling on the power cord. Always grip
plug firmly and pull straight out from
the outlet.
All electrical repairs must be carried
o u t b y q u a lifie d e le c tric ia n s .
Inadequate repairs may result in a
major source of danger for the user of
the air conditoiner.
Do not damage any parts of the air
conditioner that carry refrigerant by
pie rcing or pe rfora ting the a ir
conditione r's tube s with s ha rp or
pointed items, crushing or twisting any
tubes, or scraping the coatings off the
surfaces. If the refrigerant spurts out
and gets into eyes, it may result in
serious eye injuries.
Do not obs truct or cove r the
ventilation grille of the air conditioner.
Do not put fingers or any other things
into the inlet/outlet and swing louver.
Do not allow children to play with the
a ir conditione r. In no ca s e s hould
2
Download from Www.Somanuals.com. All Manuals Search And Download.
Parts
Indoor unit
1
2
1
Outlet grill
2
Operation panel
3
Inlet grill
4
Air filter
5
Remote-controller
AM
TEMP
ON
5
OFF
SWING
FAN
3
4
MODE
CLOCK
TIMER
SLEEP
SET
LOCK RESET
Outdoor unit
6
7
6
Air inlet
[At side and rear]
Air outlet
7
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Parts
Manual Operation
5
3
6
2
7
9
SET
AM
PM
TIMER
CLOCK
SET
TEMP
TIME
TEMP
TEMP
:
MODE
ROOM
TEMP
TIMER ON
AM
PM
TIMER OFF
AM
PM
TIME
ON
C
:
A
U
T
OFF
MID HIGH
LOW
Ion
SLEEP
FAN SPEED
SWING
:
O
8
10
4
1
Remote controlled operation
HEAT
FAN
DRY
OPERATION
COOL
9
Power ON/OFF
3
TEMP
Used for unit
start and stop.
Used to select your
desired temp.
SIGNAL
AUTO
AUTO
AUTO
SENDING
FAN
8
SWING
FAN SPEED
10
SWING
Used to select fan
speed: LO, MED,
HI, AUTO.
Used to set auto
fan direction
AM
PM
AM
PM
TEMP
ON
OFF
ON
OFF
AM
PM
AM
PM
LO
MED
AM
PM
AM
PM
1
SLEEP
CLOCK
2
MODE
Used to select
sleep mode
TEMP
Used to select
AUTO run,
COOL, DRY,
HEAT and FAN
operation.
TEMP
TIMER OFF
ON
OFF
ON
OFF
SWING
FAN
SWING
FAN
HI
AUTO
MODE
CLOCK
TIMER
SLEEP
SET
MODE
CLOCK
TIMER
SLEEP
SET
AUTO
TIMER ON
7
CLOCK
4
SET
Used to set correct
time.
Used to confirm
Timer and
Clock setting.
LOCK RESET
LOCK RESET
6
TIMER
Used to select
TIMER ON, TIMER
OFF, TIMER
5
HOUR
Used to set clock
and timer setting.
SLEEP
11
LOCK
RESET
Used to lock buttons
and LCD display.
Used to reset the controller
back to normal condition.
Note: Auxiliary heat function is not available.
For cooling only type, heating function is not available.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation
AM
TIMER
CLOCK
SET
TIM
:
TEMP
TEMP
MODE
TIM2
OFF
Clock s et
ON
SLEEP
FAN SPEED
SWING
1
When unit is started for the first time
3
and after replacing batteries in remote
controller, clock should be adjusted as follows:
Press CLOCK button, "AM"or "PM" flashes.
Press
or to set correct time. Each press will increase
or decrease 1min . If the button is kept depressed, time
will change quickly.
AM
After time setting is confirmed, press SET, "AM" and "PM"
stop flashing, while clock starts working.
TEMP
ON
OFF
SWING
FAN
Remote contronller's operation
MODE
CLOCK
TIMER
SLEEP
SET
When in use, put the signal transmission head directly
to the receiver hole on the indoor unit
The distance between the signal transmission head and
the receiver hole should be within 7m without any
obsacles as well.
LOCK RESET
Don't throw the controller, prevent it from being damaged.
When electronic-started type fluorescent lamp or change-over
type fluorescent lamp or wireless telephone is installed in the
room, the receiver is apt to be disturbed in receiving the signal
so the distance to the indoor unit should be shorter.
reset key
Loading of the battery
Slinghtly press " " and push down the cover.
Load the batteries as illustrated.
2 R-03 dry batteries, (cylinder)
Be sure that the loading is in line with the "+"/"-" pole
request as illustrated.
Put on the cover again
Confirmation indicator:
In disorderation, reload the batteries or load the new batteries after 5 mins.
Note:The waster batteries should be disposed properly,use two new same-type batteries when loading.
If the remote controller canít function normally or doesnít work at all,use a sharp-pointed item to pres
the reset key.
Hint:Remove the batteries in case unit wonít be in usaged for a long period.
If there are any displays after taking-out just need to press reset key.
THE MACHINE IS ADAPTIVE IN FOLLOWING SITUATION
Applicable ambient temperature range:
Maximum: D.B/W.B
Minimum: D.B/W.B
Maximum: D.B/W.B
Minimum: D.B
32 C/23 C
18 C/14 C
43 C/26 C
18 C
27 C
15 C
24 C/18 C
-7 C/-8 C
Indoor
Outdoor
Indoor
Cooling
Heating
Maximum: D.B
Minimum: D.B
Maximum: D.B/W.B
Minimum: D.B/W.B
Outdoor
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation
Auto
Manual Operation
2
AM
SET
TEMP
TIMER
CLOCK
SET
TIME
TIME
TEMP
TEMP
:
MODE
ON
C
A
U
T
OFF
LOW MID HIGH
SLEEP
FAN SPEED
SWING
O
1
3
1
Press ON/OFF button
Unit starts running.
Remote-controlled Operation
The previous status appears on the display
(except. TIMER, SLEEP and SWING mode)
2
Press MODE button. For each press, operation
mode changes as follows:
AUTO
AM
Manual
Remote
AUTO COOL DRY HEAT FAN
TEMP
AUTO COOL DRY HEAT FAN
Select Auto run,
controlled
ON
OFF
SWING
FAN
1
3
MODE
SLEEP
SET
"
" appears and auto run starts.
2CLOCK
3
Press ON/OFF button
Unit stops running.
TIMER
LOCK RESET
Note:
During Auto run operation, temp. setting will not be shown in
LCD display, unit will select heating, cooling or fan operation
according to the room temp.
6
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation
Cooling
Manual Operation
3
2
AM
SET
TEMP
TIMER
CLOCK
SET
TIME
TIME
TEMP
TEMP
:
MODE
C
ON
OFF
LOW MID HIGH
SLEEP
FAN SPEED
SWING
1
5
4
1
2
Press ON/OFF button
Unit starts running.
The previous status appears on the display
(except. TIMER, SLEEP and SWING mode)
Remote-controlled Operation
Press MODE button. For each press,
operation mode changes as follows:
Manual
AUTO COOL DRY HEAT FAN
Remote
controller
AUTO COOL DRY HEAT FAN
AM
Select cooling operation, Shows"
Cooling operation starts.
"
3
Select temp. button
Press TEMP button
TEMP
Every time the button is pressed, temp. setting
increases 1 C
3
ON
OFF
SWING
Every time the button is pressed, temp. setting
decreases 1 C
If the button is kept pressed, setting will increase or
decrease quickly.
FAN4
1
5
MODE
CLOCK
TIMER
SLEEP
2
SET
4
Press FAN button. For each press, fan speed
changes as follows:
HIGH
LOW MID
LOW MID HIGH
LOW
LOW MID
Manual
LOCK RESET
AUTO
Remote
controlled
LOW
MID
HIGH
AUTO
Unit runs at the speed displayed on LCD.
5
Press ON/OFF button
Unit stops running,and when ectering this mode for the
next time,it will show the previous setting.
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation
Dry
Manual Operation
3
2
SET
TEMP
AM
TIMER
CLOCK
SET
TIME
TIME
TEMP
TEMP
:
MODE
ON
OFF
C
LOW
SLEEP
FAN SPEED
SWING
1
5
4
Remote-controlled Operation
1
Press ON/OFF button
Unit starts running.
The previous status appears on the display
(except. TIMER, SLEEP and SWING mode)
2
Press MODE button. For each press, operation mode changes
as follows:
Manual
HEAT
AUTO COOL DRY FAN
AUTO
Remote
controller
HEAT
AUTO COOL DRY FAN
AM
Select Drying operation shows"
Dry operation starts
"
3
Select temp. button
Press TEMP button
TEMP
Every time the button is pressed, temp. setting increases 1 C
Every time the button is pressed, temp. setting decreases 1 C
If the button is kept pressed, setting will increase or decrease quickly.
3
ON
OFF
FAN4
SWING
1
5
4
Press FAN button. For each press, fan speed changes as follows:
MODE
CLOCK
TIMER
SLEEP
A
LOW
MID HIGH
LOW MID
MID
HIGH
LOW
LOW
U
T
Manual
O
2
SET
AUTO
Remote
controlled
LOCK RESET
LOW
MID
HIGH
AUTO
Unit runs at the speed displayed on LCD.
In DRY mode, when room temp.becomes 2 C higher than temp. setting,
unit will run intermittently at LOW speed regardless of FAN setting.
COOL operation starts when
room
5
Press ON/OFF button
Ultra-low air flow
Unit stops running, and when
entering this mode for the next
On reaching 2 C higher than temp.
time, it will show the previous setting
setting,unitwill run in mild DRY mode.
Temp.setting+2 C
Temp.setting
8
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation
Heating
Note: For cooling only type, this function is invalid.
Manual Operation
3
2
SET
TEMP
AM
TIMER
CLOCK
SET
TIME
TIME
TEMP
TEMP
:
MODE
ON
OFF
C
LOW
SLEEP
FAN SPEED
SWING
1
5
4
Remote-controlled Operation
1
Press ON/OFF button
Unit starts running.
The previous status appears on the display
(except. TIMER, SLEEP and SWING mode)
2
Press MODE button. For each press,operation mode changes
as follows:
Manual
HEAT
HEAT
AUTO COOL DRY FAN
AUTO COOL DRY FAN
Remote
controller
AM
Select Heating operation " " appears and
Heating operation starts.
TEMP
3
Select temp. button
Press TEMP button
3
ON
Every time the button is pressed, temp. setting increases 1 C
Every time the button is pressed, temp. setting decreases 1 C
OFF
SWING
FAN4
1
5
If the button is kept pressed, setting will increase or decrease
quickly.
MODE
CLOCK
TIMER
SLEEP
2
SET
4
Press FAN button. For each press, fan speed changes as follows:
A
LOW MID
HIGH
LOW
LOW
MID
LOW
MID HIGH
U
T
LOCK RESET
Manual
O
AUTO
Remote
controlled
LOW
MID
HIGH
AUTO
In the mode,warm air will blow out after a short period of
time due to cold-draft prevention function.
5
Press ON/OFF button
Unit stops setting when entering this mode next time.
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation
Fan
Manual Operation
2
SET
TEMP
AM
TIMER
CLOCK
SET
TIME
TIME
TEMP
TEMP
:
MODE
C
ON
OFF
LO
SLEEP
FAN SPEED
SWING
1
4
3
Remote-controlled Operation
1
2
Press ON/OFF button
Unit starts running.
The previous status appears on the display
(except. TIMER, SLEEP and SWING mode)
Press MODE button. For each press,operation mode changes
as follows:
Manual
HEAT
HEAT
AUTO COOL DRY FAN
AUTO COOL DRY FAN
AM
Remote
controller
TEMP
Select Fan operation shows " ", Fan operation starts.
ON
OFF
3
Press FAN button. For each press, fan speed changes as
follows:
FAN3
SWING
4
1
HIGH
LOW
LOW MID
LOW MID
MODE
CLOCK
TIMER
SLEEP
Manual
2
SET
Remote
controlled
LOW
MID
HIGH
LOCK RESET
4
Press ON/OFF button
Unit stops running, and when entering this mode for the
next time, it will show the previous setting.
Note:
In this mode, temp. can't be selected, temp.setting will not be
show in LCD display.In Fan operation mode, "AUTO" fan speed
is not available. Operation cycles are as follows:
LOW
MID
HIGH
10
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation
SLEEP
AM
SET
TEMP
TIMER
TIME
TIME
TEMP
TEMP
:
MODE
ON
C
CLOCK
SET
OFF
LOW MID HIGH
SLEEP
FAN SPEED
SWING
Remote-controlled operation
Before sleeping you can press the Sleep button. The
conditioner will run under comfort sleep mode, and give
you a comfort sleep.
The Sleep running starts
The Sleep running stops
About 6 hours
Rises 1 C
Us age of the Sleep function
After starting, set the Run mode and press the Sleep button.
Run mode
1 hour
1. In cooling and dry
Rises 1 C
1 hour
After starting of the Sleep operation, the temperature Will
be raised for 1 C higher than the set temperature 1 hour later,
and be raised for 1 C after another hour. It continues under
that condition for 6 hours, then the machine will be switched
off. The temperature is higher than the set temperature so
as to avoid catching cold in sleeping.
Closc down
the machine
Set the
temperature
In cooling and dry
2. In heating ( the single-cooling conditioners do not have
the function)
After the Sleep running starts, the temperature will drop for 2 C
after another one hour. The temperature will raise for 1 C after
3 hours running under the above temperature, and the conditioner
will be closed down after running for 3 hours. The temperature
is lower than the set temperature so as to avoid uneasiness in
sleeping.
AM
TEMP
Close down
the machine
Set the
temperature
ON
OFF
SWING
FAN
1 hour
Drop for 2 C
1 hour
MODE
CLOCK
TIMER
SLEEP
SET
Drop for 2 C
About 3 hours
Raise 1 C
3 hours
LOCK RESET
The Sleep running starts
The Sleep running stops
In heating
3. In automatic running
The conditioner will run under automatically selected working
mode of sleeping.
4. In Fan running
The Sleep function is invalid.
11
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation
Timer on/off operation
Manual Operation
3
2
AM
TIMER
CLOCK
SET
TIME
TIME
TEMP
:
MODE
TIMER ON
AM
ROOM
TEMP
ON
C
TEMP
:
OFF
LOW MID HIGH
SLEEP
FAN SPEED
SWING
1
4
Remote controlled operation
TIMER operation
Set Clock correctly before starting Timer operation (refer to page 5)
You can let unit start or stop automatically at following times: Before you wake up in
the moring, or get back from outside or after you fall asleep at night.
TIMER ON/OFF
(1) After unit s tart, s elect your des ired operation mode.
Operation mode will be displayed on LCD.
(2) TIMER mode s election
Press TIMER button to change TIMER mode.
Every time the button is pressed, display changes as follows:
AM
12:00
12:00
TIMER ON
TIMER OFF
TIMER ON
TIMER OFF
BLANK
BLANK
AM
AM
AM
12:00
12:00
Manual
TIMER ON
TIMER OFF
TIMER ON-OFF
AM
ON
OFF
ON
OFF
AM
AM
Remote
control
ON
12:00
12:00
12:00
12:00
PM
PM
AM
TIMER ON
TIMER OFF
TIMER ON-OFF
Select your desires TIMER mide (TIMER ON or TIMEROFF) ON or
OFF will flash.
TEMP
ON
OFF
(3) Timer s etting
SWING
FAN
Press HOUR
/
button.
Every time the button is pressed, time increases 10 min, If
button is kept pressed, time will change quickly.
Every time the button is pressed, time decreases 10 min, If
button is kept pressed, time will change quickly. Time will
be shown on LCD. It can be adjusted within 24 hours.
1
MODE
CLOCK
TIMER
SLEEP
SET
4
3
(4) Confirming your s etting
2
OCK
RESET
ON
After setting correct time, press SET button to confirm, "
"
OFF
or "
" stops flashing.
Time displayed: Unit starts or stops at x hour x min (TIMER
ON or TIMER OFF)
Timer mode indicator on indoor unit lights up.
To cancel TIMER mode
Just press TIMER button several times until TIMER mode disappears.
Hints
After replacing batteries or a power failure happens, Time setting should be reset.
Remote controller possesses memory function when use TIMER mode next time, just
Press SET button after mode selecting if timer setting is the same as previous one.
12
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation
Timer on-off function
Manual Operation
3
4
2
AM
TIMER ON
TIMER
CLOCK
SET
TIME
TIME
TEMP
:
MODE
ROOM
TEMP
ON
TEMP
C
AM
:
OFF
LO MED HI
TIMER OFF
SLEEP
AM
FAN SPEED
SWING
5
1
6
Remote controlled operation
TIMER ON-OFF
(1) After unit s tart, s elect your des ired operation mode.
Operation mode will be displayed on LCD.
(2) TIMER mode s election
Press TIMER button to change TIMER mode.
Every time the button is pressed, display changes as follows:
AM
12:00
12:00
TIMER ON
TIMER OFF
TIMER ON
TIMER OFF
BLANK
BLANK
AM
AM
AM
12:00
12:00
Manual
TIMER ON
TIMER OFF
TIMER ON-OFF
ON
OFF
ON
OFF
AM
AM
Remote
control
12:00
12:00
12:00
12:00
PM
PM
TIMER ON
TIMER OFF
TIMER ON-OFF
AM
OFF
(3) Timer s etting for TIMER ON
Press HOUR button.
ON
AM
PM
Every time the button is pressed, time increases 10 min. If
button is kept pressed, time will change quickly.
Every time the button is pressed, time decreases 10 min. If
button is kept pressed, time will change quickly.
Time will be shown on LCD.
TEMP
ON
OFF
SWING
FAN
It can be adjusted within 24 hours.
AM refers to morning and PM to afternoon.
1
MODE
CLOCK
TIMER
SLEEP
(4) Time confirming for TIMER ON
SET
After time setting, press TIMER button to confirm,
3
6
ON
OFF
" starts blinking.
"
" stops blinking, while "
4
Time displayed: Unit starts or stops at x hour x min
2LOCK
5
RESET
(5) Time s etting for TIMER OFF
Follow the same procedure in "Time setting for TIMER ON".
(6) Time confirming for TIMER OFF
OFF
After time setting, press SET button to confirm, "
Time displayed: Unit stops at x hour x min
" stops flashing.
To cancel TIMER mode
Just press TIMER button several times until TIMER mode disappears.
According to the Time setting sequence of TIMER ON or TIMER OFF,
either ON-OFF or OFF-ON can be achieved.
13
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation
Air flow adjustment
Swing louvers
(Vertical louvers)
Horizontal louvers
(Adjust by hand)
Up and down
Adjust the louvers by hand to proper position.
Put louvers at up position in cooling and down position in heating mode.
This will be helpful to keep an even room temp.
Note:
Notice:
In cooling or dry operation, don't put horizontal louvers at downward
position for a long time, or outlet grill might get frosted. Don't expose your
skin to cool or warm air for a long time.
AM
TIMER
TIME
TIME
TEMP
TEMP
:
MODE
ROOM
TEMP
C
ON
CLOCK
SET
AUTO
A
U
T
LOW MID HIGH
OFF
SLEEP
FAN SPEED
SWING
O
AM
Side from side
Swing
TEMP
ON
OFF
SWIN
FAN
Press SWING "
appears on the display, the vertical
louvers move from side to side.
" or "
"
MODE
CLOCK
TIMER
SLEEP
SET
Fixed position
LOCK RESET
Press the SWING again to fix the
vertical louvers at your desired position.
14
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation hints
Unit operation
Protection devices inside the unit will activate to stop unit operation, when ambient
temp. is extremely low or high.
When unit is running under high humidity in cooling or dehumidifying mode, conden-
sate might appear at outlet grill.
3-min delay protection
Unit will not restart until 3 min have elapsed for the protection of the unit.
Fan s peed changes
When Fan speed is set at Auto in cooling mode, it will be automatically reduced as
room temp. is approaching temp. setting.
In heating mode. when room temp. reaches temp. setting, compressor will stop and
fan speed LOW or stop.
In dry mode, fan speed will change automatically.
Cold draft prevention
In heating mode, indoor fan will not run for the first 2-5 min. due to cold draft
prevention.
Defros ting
When frost accumulates on heat exchanger in heating mode, unit will start defrosting
automatically.
During defrosting, both indoor and outdoor fan stop.
After defrosting, unit resumes running.
Us e objectively
Heat pump works by means of absorbing outside heat to warm room air, so outdoor
temp. degree will affect unit's heating efficiency.
15
Download from Www.Somanuals.com. All Manuals Search And Download.
Energy s aving
Keep proper room temp.
Too cold or too warm is no
good to your health, and
power consumption will be
increased as well.
Proper temp.
Air filter s hould be
periodically cleaned
If air filter is clogged:
It will cause poor cooling and
heating efficiency, higher power
consumption and even problem
may occur. In cooling operation,
water will flow out.
Us e Timer effectively
OFF
ON
AM 8:00
You may use Timer mode to
keep a comfortable room temp.
when you wake up or come
home from outside.
PM
5:00
Avoid direct s unlight
and air flow
Adjus t air flow
properly
16
Download from Www.Somanuals.com. All Manuals Search And Download.
Cautions for the operation
Keep a smooth air flow
to inlet and outlet of both
indoor and outdoor unit.
Use control panel to
operate the unit.
ON/OFF
To avoid accident, don't
insert any object into air
grill.
Don't press buttons unless
necessary.
OFF
ON
OFF
Not do
Don't spray any paint or
insecticide on the unit.
ON
OFF
Use fuses of the right
capacity. Never use iron
or copper wires instead.
This will cause damage or even fire accident.
Don't splash water directly
on indoor unit.
This could be
very dangerous
Don't touch moving outlet
grills.
17
Download from Www.Somanuals.com. All Manuals Search And Download.
Maintenance
Disconnect power
supply
Don't touch it with
wet hand
Don't wash with hot water
or solvent to clean the unit
Air filter cleaning
Pull it out from top as shown in Fig.
Use water or vacuum cleaner to clean
it. If it is extremely dirty, wash it with
neutral detergent or soap water.
Wash it with clean water and install it
after complete dry.
Caution:
Don't use hot water over 40 C, as this may cause damage to air filter.
Wipe air filter carefully.
Indoor and outdoor cleaning
Clean it with warm and wet cloth or with neutral detergent, then wipe it dry with
clean and soft cloth.
If air conditioner is very dirty, clean it with cloth soaked in neutral detergent,
then wipe off the detergent with clean water.
Don't use water higher than 40 C , which will cause discoloring and deformation .
Don't use insecticide or other chemical detergents.
18
Download from Www.Somanuals.com. All Manuals Search And Download.
Maintenance
After s eas on maintenance
Let the unit run in Fan mode for half a day in a
fine weather to dry completely the unit inside.
Turn off the unit and pull out
power plug.
There might be certain power
consumption even if unit is
stopped.
Clean air filter and indoor unit, cover outdoor unit after cleaning.
Before s eas on maintenance
Check if there are obstacles at inlet and outlet of indoor and outdoor
unit, whick will reduce unit efficiency.
Don't fail to attach air filter after making sure
it is cleaned.
Dust will enter into unit causing damages or
faults if it is running without air filter.
To protect compressor at start, please connect external power supply to the
unit 12 hrs prior to starting. Also please keep the power supply switch ON
during the whole season.
19
Download from Www.Somanuals.com. All Manuals Search And Download.
Trouble s hooting
Followings are not problems
During unit start and operation or at stop, a swishing
or gurgling noise may be heard. This noise is generated
by refrigerant flowing in the system.
Sound of water flowings are
not problems.
During unit operation, a cracking noise may be heard.
This noise is generated by the casing expanding or
shrinking because of temperatuer changes.
Sound of cracking is heard.
Smells are generated.
This is because the system circulates smells from the
interior air such as the smell of cigarettes or the
painting on the unit.
During operation, white fog or
steam comes out of indoor unit.
When unit is running at places like restaurant where
dense edible oil fumeis always exist, this will happen.
To prevent frost from accumulating on indoor heat
exchanger, unit will switch to fan operation for a while
then resume cooling operation.
In cooling operation, unit switches to fan
operation.
Unit will not restart after stop.
Won't start?
Though ON/OFF button is set
to ON, unit won't resume cooling,
dry or heating operation
in 3 min after it is stopped, this
is because of 3-min-delay
protection circuit.
Please wait 3 minutes
No outlet air or fan speed can't be changed
in dry mode.
Unit will reduce fan speed repeatedly and automatically
if room temp. is too low in dry operation.
In heating operation, water or steam are
blown out of indoor unit.
This occurs when frost accumulated
on the outdoor unit is removed.
(during defrosting operation)
In heating operation, indoor fan won't stop
even if unit is stopped.
After unit stops, indoor fan will go on running
until indoor unit cools down.
20
Download from Www.Somanuals.com. All Manuals Search And Download.
When problems occur?
Before as k for s ervices , pleas e firs t check your unit agains t following.
Air conditioner won't s tart.
Is city power supply normal?
Is leakage current breaker
activated?
Is power supply switch
turned on?
This is very dangerous, please
disconnect power supply
immediately and contact your
dealer.
Power
failure?
Power supply
switch is not
set at ON.
Poor cooling or heating
Are there any obstacles at inlet
or outlet grill?
Are operation controlls
adjusted correctly
as specified?
Is air filter too dirty?
Proper
temp
Are horizontal louvers
at up position (in
heating mode)?
Any doors or windows left
open?
Poor cooling
If there are unexpected heat
sources in the room?
Too many people in the room?
Is there any direct sunlight
in the room?
If your unit still can't work properly after above mentioned
checks, or following problems occur, please stop it immediately
and contact your dealer.
Fuses or circuit breakers often blow out.
Water comes out in cooling/dry operation.
Operation is abnormal or sound is heard.
If the fuse on PC board is broken please change it with the type
of 50F.3.15A/250V.
21
Download from Www.Somanuals.com. All Manuals Search And Download.
Indoor & outdoor unit connection
Over 10cm
Over 10cm
Over 100cm
power cable length
Approx
1.5m
Approx
2m
pipe direction
Left
Rear
Right
Bottom
Over 10cm
Over 10cm
Over 15cm
Over 60cm
22
Download from Www.Somanuals.com. All Manuals Search And Download.
Indoor & outdoor unit connection
Over 10cm
Over 10cm
Over 100cm
power cable length
Approx
1.5m
Approx
2m
pipe direction
Left
Rear
Right
Bottom
Over 10cm
Over 10cm
Over 15cm
Over 60cm
22
Download from Www.Somanuals.com. All Manuals Search And Download.
Tools neces s ary
Parts in the following list are accessories for
the unit installation which can be used if
necessary.
Tools necessary
1. Screw driver
2. Hacksaw
Shape and description
No.
QTY
3. 70mm dia. hole core drill
4. Spanner (dia. 17, 27mm)
5. Spanner (14, 17, 27mm)
6. Pipe cutter
7. Flaring tool
8. Knife
9. Nipper
10. Gas leakage detector
or soap water
11. Measuring tape
12. Reamer
13. Refrigerant oil
1
2
3
1
3
1
2
2
1
Remote controller
Cement nail
Drain hose
4
5
6
7
8
Heat-insalution pipe
L-shaped metal
Fall-prevention fitting metal
Wire clip
4
1
3
Drain elbow
Standard accessories
Following parts shall be
field supplied
Self-tapping scerw
Rubber pad
9
10
11
4
1
1
Hexagon wrench
Wall hole cover
Piping hole cover
Dry battery 7#
Parts name
Adhesive tape
Pipe clip
Mark
A
12
13
B
1
2
1
C Connecting hose
14
15
16
Insulation material
Putty
D
E
F
Putty
6
1
Plastic clamp
Drain hose
Refrigerant oil
***
17
For cooling only type.drain elbow is not
available
23
Download from Www.Somanuals.com. All Manuals Search And Download.
Ins tallation procedures
Display of whole unit
Try to bring the packed unit to the installation place.
When it is inevitable to unpack the unit, be careful not to damage the unit. Wrap it with
nylon etc.
After unpacking, be sure to put it with the front side of the unit facing up.
Delivery
Facing up
Note: When delivering, don't hold plastic
parts like inlet and outlet grill etc.
Installation of outdoor unit
Selection of installation place
over 30cm
Place strong enough to support the unit and will
not cause vibration and noise.
Place where discharged wind and noise doesn't
cause a nuisance to the neighbors.
Place where is less affected by rain or direct sunlight
and is sufficiently ventilated, or to install a shield.
Place with enough space for smooth air flow.
over 10cm
over 10cm
over 15cm
over 60cm
Fixing of the unit
Fix outdoor unit using M10 bolt to concrete floor horizontally.
If installed on the wall or on top of a roof, bracket should be fixed securely to resist
earthquake or storms.
Use rubber pad during installation against unit vibration.
190
580
190
Installation dimension of outdoor unit (mm)
24
Download from Www.Somanuals.com. All Manuals Search And Download.
Ins tallation procedures
Installation of indoor unit
Selection of installation place
Place where it is easy to route drainage pipe and outdoor piping.
Place away from heat source and with less direct sunlight.
Place where cool and warm air could be delivered evenly to every corner of the room.
Place near power supply socket. Leave enough space around the unit (refer to installation
drawings).
Fixing of the unit
Position of the wall hole
1.
Wall hole should be decided according to installtion place and piping direction. (refer
to installation drawings)
Making a wall hole
2.
Drill a hole of 70mm dia. with a little slope towards outside.
Install piping hole cover and seal it with putty after installation.
INDOOR
OUTDOOR UNIT
wall thinkness
wall hole
70mm
( Cross section of wall hole )
Fixing of indoor unit
To prevent it from fall off, please fix the unit with fall-prevention fitting at wall and
L-shaped metal at floor.
Self-tapping
screw
all-prevention fitting metal (accessory)
Wood screw
Please install the whole unit horizontally,
with a slop of 1 degree at front and rear,
left and right.
L-shaped metal
(accessory)
25
Download from Www.Somanuals.com. All Manuals Search And Download.
Ins tallation procedures
Installation of fall-prevention fitting metal:
Fix the fitting metal to the wall by screws so that there is no clearance between them.
With the unit set up vertically, fix the fitting metal to the unit with screws while making
an adjustment at the long portion of the hole so that there is no clearance between the
upper surface and the fitting metal.
Installation of L-shaped metal
Fix to the unit by screws so that there is no clearance between the fitting metal and
the unit.
After confirming that the unit has been set up vertically to the floor, fix it to the floor
by bolt.
Piping connection
1. Connecting method
Apply refrigerant oil at half union and flare nut.
To bend a pipe, give the roundness as large as possible not to crash the pipe.
When connecting pipe, hold the pipe centre to centre then screw nut on by hand,
refer to Fig.
Be careful not to let foreign matters, such as sands enter the pipe.
Forced fastening without centering may
damage the threads and cause a gas leakage.
Pipe dia
Fastening torque
.
42N m
Liquid pipe 9.52mm(3/8")
Gas pipe 19.05mm(5/8")
.
110N m
26
Download from Www.Somanuals.com. All Manuals Search And Download.
Ins tallation procedures
2. Piping connection of indoor unit
Arrangement of piping and drainage pipe
After opening inlet grill, you will see a control
box as shown in the Fig.
Remove the cover before working.
Cut away, with a hammer or a saw, the lid for piping according to piping direction.
Insulation material
Drain hose
Connecting electric cable
for indoor and outdoor unit
Copper tube
According to the piping method, connect the piping on indoor unit with union of
connecting pipe.
Arrange the piping as per the wall hole and bind drain hose connecting electric cable and
piping together with polyethylene tape.
Insert the bound piping connecting electric cable and drain hose through wall hole to
connect with outdoor unit.
Arrangement of drain hose
Drain hose shall be placed in under place.
There should be a slope when arrange drain hose. Avoid up and down waves in drain hose.
Indoor unit
Up
Down
Bad
Slope
Good
If humidity is high, drain pipe( especially in room and indoor unit ) must be covered
with insulation material.
27
Download from Www.Somanuals.com. All Manuals Search And Download.
Ins tallation procedures
3. Piping connection of outdoor unit.
Connect the connecting pipe and inlet and outlet liquid pipe according to the piping
method.
4.Purging method
Discharge the air out of the indoor unit and the refrigerant pipe by vacuumizing
(1) Fasten all the nuts of the indoor and outdoor pipes to make these parts out of leakage.
(2) Under the condition of the complete close of the indoor and outdoor valve center (both
liquid and gas side),dismount the repair valve cap.Vacuumizing through the charge
mouth of the repair valve.
(3) After vacuumizing fasten the repair valve,and dismount the cap of the big and small
stop valve,then loosen the stop valve center completely and fasten the big and small
stop valve.
5.Extra charging amount of the refrigerant
When piping is longer than 5 m, charge additional refrigerant specified in this list.
25m
Pipe length
5m
10m
250
15m
500
20m
750
30m
Refrigerant charge (g)
1000
1250
28
Download from Www.Somanuals.com. All Manuals Search And Download.
Ins tallation procedures
Electric wiring
Note:
Electric wiring must be done by qualified person.
Use copper wire only, the parameter of connecting cable is H07RN-F4 X 0.75mm .
The power cable should be over 3G2.5mm2, the power cable is self-provided.
2
Wiring of indoor unit
Insert the cable from outside the wall hole where piping already exist.
Pull it out from front.
Loosen terminal screws and insert cable end fully into terminal block, then tighten it.
Pull the cable gently to make sure it is tight.
Replace cover after wiring.
OK
NO
terminal block
table clanip
Wiring of outdoor unit
Insert the cable from inside the wall hole where piping already exists.
Pull it out from front.
Loose terminal screw and insert cable end fully into terminal block, then tighten it.
Pull the cable gently to make sure it is tight.
Terminal block (indoor)
Replace cover after wiring.
power supply
2
3
1
2
3
N
1
S
T
R
2
N
3
1
S
T
R
Terminal block (outdoor)
Note:
When connecting indoor and outdoor wire, check the number on indoor and outdoor
terminal blocks. Terminals of same number and same color shall be connected by the
same wire.
Incorrect wiring may damage air conditioner's controller or cause operation failure.
29
Download from Www.Somanuals.com. All Manuals Search And Download.
Others
1. Power supply
Air conditioner must use an exclusive line (over 30A)
When installation air conditioner in a wet place, try to use a circuit breaker against
Current leakage.
For installation in other places, use circuit breaker as far as possible.
The breaker of the air conditioner should be all-pole switch ; and the distance between
its two contacts should be no less 3 mm.
Such means for disconnection must be incorporation in the fixed wiring
2. Pipe cutting and flaring
Be sure to carry out deburring after pipe cutting with a pipe cutter.
Insert flaring tool to make a flare.
Pipe dia.
Dimension A(mm)
1.0 ~ 1.2
A
Flaring tool
Liquid pipe
Gas pipe
9.52mm (3/8")
19.05mm (3/4")
1.4 ~ 2.2
Correct
Incorrect
Lean Damaged flare Crack
Partial Too outside
Installation inspection and test run:
Please operate unit according to this Manual.
Items to be checked during test run. Please made a " "in " "
Are there any gas leakage?
How is insulation at piping connection carried out?
Are electric wires of indoor and outdoor unit firmly inserted into terminal block?
Is electric wiring of indoor and outdoor securely fixed?
Is draminage securely carried out?
Is earth line ( grounding ) securely connected?
Is power supply voltage abided by the code?
Is there any noise?
Is control display normal?
Is cooling operation normal?
Is room temp. regulator normal?
30
Download from Www.Somanuals.com. All Manuals Search And Download.
|