WINDOW TYPE ROOM AIR CONDITIONER
HW-09LN03
HW-12LN03
No.0010515690
Download from Www.Somanuals.com. All Manuals Search And Download.
Front panel
Air inlet (indoor side)
Machine body
Air outlet (indoor side)
Air inlet (outdoor side)
Display panel
Power plug
Air filter (inside)
1
2
3
4
5
6
7
FAN SPEED
8
MODE
FAN,COOL,DEHUM.
:HIGH or LOW.
FAN SPEED
SWING
ENERGY SAVER
Used to activate ENERGY SAVER option,reduce energy consumption and noise.
POWER
2
Download from Www.Somanuals.com. All Manuals Search And Download.
POWER
1
2
3
MODE
FAN SPEED
FAN,COOL,DEHUM.
FAN SPEED
5
TIMER button
Used for TIMER start or stop .
4
5
TEMP.orTIME set
Used to set TIME or TEMP. setting.
E-S
ENERGY SAVER
6
7
SWING
E-S
3
Download from Www.Somanuals.com. All Manuals Search And Download.
COOL
1.Start
Press POWER button
2. Select operation mode
Press MODE button. For each press, operation mode
FAN
COOL
DEHUM
changes as follows:
Then select COOL operation.
When the COOL display lights bright,the unit will
be working under the cooling function.
FAN SPEED
3. Select temp. setting
5
4. Fan speed selection
If you choose the FAN SPEED mode you can run the
fan in one of the 2 speeds: HIGH or LOW.
Select desired setting.
Change air flow direction if necessary.
5. Stop
Press POWER button again.
E-S
FAN SPEED
at outlet
4
Download from Www.Somanuals.com. All Manuals Search And Download.
DEHUMID mode
1. Start
Press POWER button.
2. Select operation mode
Press MODE button. For each press, operation mode
changes as follows:
FAN
COOL
DEHUM
Then select DEHUMID operation.
When the DEHUM display lights bright,The unit will be
working under the dehumidify function.
5
If you need to only remove the moisture press the
Dehnmid button. Change air flow direction if necessary.
FAN SPEED
4
3. Select temp. setting
4. Fan speed selection
If you choose the FAN SPEED mode you can run the
fan in one of the 2 speeds:HIGHOR LOW.
Air conditioner is running under displayed fan speed.
In DRY mode, when room temperature becomes
lower than temp.setting+2oC,unit will run intermittently
at LOW speed regardless of FAN setting.
5. Stop
3UHVVꢀ32:(5ꢀEXWWRQꢀDJDLQꢁ
COOL operation starts when room
temp.is higher than temp.setting.
Ultra-low air flow
FAN SPEED
Temp.setting+2 C
Temp.setting
On reaching temp.setting +2 C
unit will run in mild DRY mode.
The compressor may cycle for 10 minutes on and 6 minuters off in
Dehumid mode.
5
Download from Www.Somanuals.com. All Manuals Search And Download.
FAN operation
1. Start
Press POWER button.
2. Select operation mode
Press MODE button. For each press, operation mode
changes as follows:
Then select FAN operation.
FAN
COOL
DEHUM
4
FAN SPEED
When the FAN display lights bright ,the unit will be
working under the fan operation.
In some days you may want to run the FAN function.
Press the FAN button.
3. Fan speed selection
Here the fan runs only at HIGH or LOW speed.
Change air flow if necessary.
4. Stop
Press POWER button again.
E-S
FAN SPEED
4
6
Download from Www.Somanuals.com. All Manuals Search And Download.
ENERGY SAVER operation
1. Start
Press POWER button.
2. Select operation mode
Press MODE button. For each press, operation mode
changes as follows:
FAN
COOL
DEHUM
4
Then select COOL operation.
When the COOL display lights bright,the unit will
be working under the COOL function.
FAN SPEED
Saving energy function only can be used
when A/C working on cooling condition.
ENERGY SAVER selection
When this function is selected, the fan will
shut off three minutes after the compressor
cycles off. This will reduce energy consumption
and noise. When the compressor turns back on,
the fan will turn on at the same time. If this
function is not selected, the fan will not shut
off when the compressor cycles off.
E-S
4. Stop
Press POWER button again.
FAN SPEED
3
4
7
Download from Www.Somanuals.com. All Manuals Search And Download.
On
Off
24
On Off
cool
On
24
Press "On"of remote controller or "TIMER" of control panel,
Off
panel,
Press "Off"of remote controller or "TIMER"of control
TIMER ON
mode
restarted
FAN SPEED
5
FAN SPEED
E-S
8
Download from Www.Somanuals.com. All Manuals Search And Download.
Power failure resume(please set and apply as necessary)
If sudden power failure occurs, the unit will resume original operation when power is supplied again.
Note:
When sudden power failure happens during unit operation in power failure resume mode, if the air
conditioner is not desired for use in a long period, please shut off the power supply in case that the
unit automatically resume operation when power is re-supplied, or press POWER to turn off the unit
when power resumes.
Operation
Adjusting of the air direction
Vertical airflow direction
Airflow Direction Vane
The Vertical Airflow Direction Vane is
manually controlled by positioning the
vane todischarge the air upward,
downward or straight out.
The horizontal air direction is adjusted
by setting the AUTO SWING ON .
Note:
It is advisable not to keep horizontal flap at downward position for a long
time in COOL or FAN mode, otherwise , condensate water might occur.
Don't move the vertical blade with hand in order to avoid the vertical blade
abnormal, using the remote controller to adjust the move of vertical blade.
9
Download from Www.Somanuals.com. All Manuals Search And Download.
pulling
Pull
Pull
ush
"
CLOSE"position, the vent door opens to allow air, smoke
or odors to be expelled from the room;
"
OPEN"position, the vent door is closed and the air inside
the room is circulated and conditioned.
CLOSE
OPEN
10
Download from Www.Somanuals.com. All Manuals Search And Download.
11
Download from Www.Somanuals.com. All Manuals Search And Download.
Disposal of the condensed water
Generally there are two methods available on disposal of the condensed water:
1. Block the bottom plate hole of the conditioner with rubber lid, install outlet pipe fitting on the
back hole and let the condensing water flow from the back hole of the conditioner. (See Fig.1 )
In this method, the accumulated condensed water in the bottom plate is hit by the fan onto the
heat exchanger, and evaporated and blown out from the machine. It can cool the heat exchanger
radiator more quickly, and improve the energy efficiency of the conditioner. But the hitting noise
by the fan at the outdoor side is relatively large.
2. Block the back hole of the conditioner with rubber lid and install outlet pipe fitting to the bottom
hole, which can make the condensed water flow out from the bottom plate. (See Fig.2)
If necessary the above two methods can both have extra pipe added on the outlet pipe fitting.
(available on the market).
(Refer to P15 for choosing these two modes.)
Fig.1
Fig.2
Outlet
pipe fitting
Rubber lid
Back hole
Back hole
Rubber lid
Outlet pipe fitting
Bottom plate hole
Bottom plate hole
Cautions
Power cord: Be sure to use the exclusive power cord.
Change installation place: If air-con need to be changed to another
place please contact the dealer, who sold you the unit.
12
Download from Www.Somanuals.com. All Manuals Search And Download.
13
Download from Www.Somanuals.com. All Manuals Search And Download.
Outlet
pipe fitting
Remote
Battery
Screw
Name Manual
Figure
Sealed gasket
Rubber lid
controller
(R-03 dry battery)
(ꢀ6
1
2
1
1
1
3
1
Quantity
14
Download from Www.Somanuals.com. All Manuals Search And Download.
MODEL
HW-09LN03
366mm
392mm
481mm
610mm
HW-12LN03
outlet pipe fitting
outlet pipe fitting
outlet pipe fitting
15
Download from Www.Somanuals.com. All Manuals Search And Download.
Wiring Diagram
0010511621
WIRING DIAGRAM
COMPRESSOR
FAN MOTOR
M
S
RECEIVING HEAD
LOUVER
MOTOR
R
C
BR
BR
B
M
CAPACITOR
M
L
H
M
BL
B
BL
OR
B
R
BL
R
BL
#
CN13
CN12
CN8 CN9
CN10
CN11
CN14
CN3
CN2
4
3
FUSE
TEMP.SENSOR
COMP.RELAY
250V/3.15A
BR
Y/G
BL
POWER SUPPLY
R:RED
NOTE:1.Because of different compressor,the dotted
part may not be used.
OR:ORANGE
B:BLACK BR:BROWN
BL:BLUE
2.There are no dotted lines on some types.
(marked with @)
Y/G:YELLOW/GREEN
Dimensions(indoor
unit) D*W*H(mm)
Circulation
Power input/
Current/Rated
current(A)
Dehumidification
Capacity(10.M/h)
12 Month
Guarantee
Net weight
(Kg)
Capacity(BTU)
Airflow(m3/h)
Rated power
input (W)
9000
980/1500 4.4/6.9
1250/1600 6.5/8.5
360
450
1.0
1.2
29.5
37
Yes
Yes
HW-09LN03
HW-12LN03
531X471X356
560X600X382
12000
Note: All capacities are gross.
Haier THERMOCOOL reserves the right to change
specifications as part of its policy of continuous improvement.
16
Download from Www.Somanuals.com. All Manuals Search And Download.
-
-
With 3 years warranty on all air- conditioner compressors, you have
peace of mind from the date of purchase
-
NATIONWIDE SALES AND SERVICES
-
-
MINNA,ILORIN,OSHOGBO,LOKOJA,
sales office
7
2719790
Download from Www.Somanuals.com. All Manuals Search And Download.
Download from Www.Somanuals.com. All Manuals Search And Download.
Download from Www.Somanuals.com. All Manuals Search And Download.
|