Operational overview  
In this section  
User guide overview  
This guide covers the standard and optional operational features of the LO100 used in HP ProLiant DL140  
G2, DL145 G2, ML150 G2, and ML110 G3 servers.  
This guide is an update to the HP ProLiant DL140 G2, DL145 G2, ML150 G2, and ML110 G3 LO100  
remote management user guides.  
Server management  
HP ProLiant Lights-Out 100 delivers basic remote control of vital server resources, supports IPMI 2.0, and  
provides system administrators with access to the server at any time, even before an operating system is  
installed on the server.  
HP ProLiant Lights-Out 100 provides text mode console redirection, DMTF SMASH compliant command  
line interface, and browser access to many of the same system management functions. You can access  
LO100 through a dedicated Ethernet port or through the server serial port.  
Server management features  
Using the Lights-Out 100 Remote Management processor, you can:  
Switch between console redirection and the command line using either the dedicated management  
or serial port  
Communicate securely using SSL and SSH  
Remotely power up and power down the server  
Perform warm or cold server reboots  
Reboot the server to a virtual floppy  
Remotely monitor server-state voltage, fan speed, and system state (S0 or S5)  
Access the System Event log  
Configure TCP/IP settings for the NIC  
Change user passwords  
Access the BMC and server controls using a standard browser or new industry standard SMASH CLP  
command-line interface  
Operational overview  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
Access command-line help  
Manage the server with IPMI 2.0-compliant applications  
Operational overview  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation  
In this section  
Remote management card kit contents ........................................................................................................ 7  
Pre-installation procedures......................................................................................................................... 7  
Post-installation procedures........................................................................................................................ 9  
Remote management card kit contents  
The remote management card kit is required only on ProLiant ML110 G3 and ProLiant ML150 G2 servers.  
ProLiant ML110 G3  
HP ProLiant ML110 G3 Remote Management Card  
Spacer support  
HP Lights-Out 100 Remote Management Card Installation Instructions for HP ProLiant ML110  
Generation 3 Servers  
ProLiant ML150 G2  
HP ProLiant ML150 G2 Remote Management Card  
Hexnut screw  
HP Lights-Out 100 Remote Management Card Installation Instructions for HP ProLiant ML150  
Generation 2 Servers  
Pre-installation procedures  
The installation procedures in this document are intended for individuals who are qualified in the servicing  
of computer equipment and trained in recognizing hazards in products with hazardous energy levels.  
WARNING: Failure to properly turn off the server before you open the server may cause  
serious damage to the equipment as well as bodily harm.  
CAUTION: Follow the ESD precautions listed in your server guide when handling the remote  
management card.  
IMPORTANT: Observe the pre- and post-configuration procedures described in later sections  
when installing the remote management card.  
NOTE: The procedures described in this section assume that the server is positioned on a flat,  
stable surface.  
1.  
Back up the server data.  
Installation  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
2.  
3.  
4.  
Shut down the operating system as outlined in the operation system instructions.  
Power off the server and all the peripherals connected to it.  
Unplug all cables from the power outlets to avoid exposure to high energy levels that can cause  
burns when parts are short-circuited by metal objects such as tools or jewelry.  
5.  
6.  
7.  
Label each cable, if not already labeled, to expedite reassembly.  
Disconnect telecommunication cables to avoid exposure to shock hazard from ringing voltages.  
Open the server according to the instructions described in your server manual.  
Installing the remote management card on ProLiant  
ML110 G3 servers  
1.  
2.  
3.  
Remove the access panel.  
Lay the server on its unexposed side to access the system board.  
Locate the remote management card connectors on the system board.  
4.  
Install the remote management card in the connectors on the system board.  
5.  
Reinstall the system covers following the "Post-installation procedures (on page 9)".  
Installation  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Installing the remote management card on ProLiant  
ML150 G2 servers  
1.  
2.  
3.  
4.  
Remove the access panel.  
Lay the server on its unexposed side to access the system board.  
Locate the remote management card connectors on the system board.  
Install the remote management card in the connectors on the system board.  
5.  
6.  
Reinstall the system covers following the "Post-installation procedures (on page 9)".  
Verify BIOS version and switch settings for the card.  
To ensure proper operation of the ProLiant ML150 G2 Lights-Out 100 remote management processor, the  
server BIOS must be version 0.28 or later. You can download the latest BIOS for your server on the HP  
The remote management card switches must be set to factory default settings.  
Switch  
SW1  
SW2  
SW3  
SW4  
Setting  
Off  
On  
On  
Off  
Post-installation procedures  
1.  
2.  
3.  
4.  
5.  
Be sure all components are installed according to the "Pre-installation procedures (on page 7)."  
Be sure you have not left any loose tools or parts inside the server.  
Reinstall any expansion boards, peripherals, board covers, and system cables previously removed.  
Reinstall the system covers.  
Connect all external cables and the AC power cord to the system.  
Installation  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
6.  
Press the power button on the front panel to turn on the server.  
Installation 10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Configuration  
In this section  
Establishing user accounts....................................................................................................................... 11  
Using the serial port ............................................................................................................................... 12  
Updating the firmware............................................................................................................................ 16  
Configuring network access  
The server is connected to the network by a standard Ethernet cable. Using this connection, you can  
access the remote management CLP, verify POST remotely, and access the BIOS Setup Utility remotely.  
To configure network access:  
1.  
2.  
Connect a standard Ethernet cable from the LO100 to a network jack.  
Obtain the DHCP IP address by using one of the following methods:  
o
o
Look at the DHCP clients table.  
Press the F10 key during POST, and read the IP address from the BIOS Setup Utility under  
Advanced/IPMI/LAN Setting. See "Obtaining a DHCP IP address from the BIOS Setup Utility (on  
page 14)" for more information.  
3.  
Using the DHCP IP address, use telnet to log into the remote management CLP, or use a web  
browser to access the HTML interface.  
To set up a static IP address, see "Setting up a static IP address from the BIOS Setup Utility (on page 15)"  
for more information.  
Establishing user accounts  
LO100 supports three types of user accounts, with varying levels of permissions to view and control  
features. For more information about user accounts, see the "User administration (on page 42)" section.  
Two accounts are available by default, one of type administrator and one of type operator. While one  
user account always has the administrator privilege, the other user account is customizable.  
The administrator account enables the user to execute the full set of CLP commands and change  
management processor configuration. The default name for the administrator account is admin, and the  
default password is admin.  
The operator account enables the user to execute common commands and functions, but restricts access to  
specific functions, such as adding and changing user account information and changing the configuration  
of the management processor. Log in with the operator account to perform common functions. The default  
name for the operator account is Operator, and the default password is Operator.  
For more information about how to log in to LO100, see the "Logging in to LO100 (on page 28)"  
section.  
Configuration 11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Using the serial port  
The server serial port provides basic serial port functionality and serves as an interface to LO100. You  
can configure the system serial port for exclusive use with LO100.  
CAUTION: After enabling the serial port for use with LO100, legacy serial devices might not  
function correctly if attached to the serial port.  
You must configure the LO100 serial port hardware parameters to work with your respective serial port  
communications software. LO100 serial port configuration is controlled through the BIOS Setup Utility.  
Enabling serial access to the LO100  
1.  
2.  
Power on the server by pressing the Power On/Off button on the front panel.  
When POST displays the message, ROM-Based Setup, press the F10 key. If the server has an  
administrator password configured, the system prompts you to enter the password. If the server does  
not have a password configured, the main screen of the BIOS Setup Utility appears.  
3.  
On HP ProLiant ML150 G2 servers:  
a. Press the right arrow () key to navigate to the Advanced menu.  
b. Press the down arrow () key to scroll to IO Device Configuration. Press the Enter key.  
c. Select Serial Port A, and press the Enter key to toggle between Enabled and Disabled. Select  
Enabled.  
d. Press the Esc key to return to the Advanced menu.  
e. Press the down arrow () key to scroll to IPMI. Press the Enter key.  
f. Press the down arrow () key to scroll to the LAN Settings submenu. Press the Enter key.  
g. Confirm the following settings:  
Ping Response: [Enabled]  
Telenet Access: [Enabled]  
HTTP Access: [Enabled}  
4.  
On HP ProLiant ML110 G3 servers:  
a. Press the right arrow () key to navigate to the Advanced menu.  
b. Press the down arrow () key to navigate to the SuperIO Configuration menu. Press the Enter key.  
c. Select Serial Port1 Address, and press the Enter key to toggle between Disabled, 3F8/IRQ4,  
3E8/IRQ4, and 2E8/IRQ3. Select 3F8/IRQ4.  
d. Review the serial port settings, and ensure that the settings match the serial port communications  
software settings used to connect to LO100.  
5.  
On HP ProLiant DL140 G2 and ProLiant DL145 G2 servers:  
a. Press the right arrow () key to navigate to the Advanced menu.  
b. Press the down arrow () key to scroll to I/O Device Configuration. Press the Enter key.  
c. Press the down arrow key () to scroll to the Serial Port menu. Press the Enter key to toggle  
between SIO COM Port and BMC COM Port. Select BMC COM Port.  
d. Press the Esc key to return to the Advanced menu.  
e. Press the down arrow () key to scroll to IPMI. Press the Enter key.  
Configuration 12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
f. Press the down arrow () key to scroll to the LAN Interface submenu. Press the Enter key.  
g. Confirm the following settings:  
BMC Telnet Service: [Enabled]  
BMC Ping Response: [Enabled]  
BMC HTTP Service: [Enabled]  
6.  
Press the F10 key to save and exit.  
LO100 serial port configuration  
1.  
2.  
Power on the server by pressing the Power On/Off button on the front panel.  
When POST displays the message, ROM-Based Setup, press the F10 key. If the server has an  
administrator password configured, the system prompts you to enter the password. If the server does  
not have a password configured, the main screen of the BIOS Setup Utility appears.  
3.  
On ProLiant DL140 G2 and ProLiant DL145 G2 servers:  
a. Press the right arrow () key to navigate to the Advanced menu.  
b. Press the down arrow () key to scroll to the Console Redirection menu. Press Enter.  
c. Press the Enter key to toggle between Enabled and Disabled. Select Enabled for the console  
redirection option.  
d. Review the serial port settings, and ensure that the settings match the serial port communications  
software settings used to connect to LO100.  
4.  
On ProLiant ML150 G2 servers:  
a. Press the right arrow () key to navigate to the Advanced menu.  
b. Press the down arrow () key to scroll to the Console Redirection menu. Press Enter.  
c. Press the Enter key to toggle between Disabled, On-board Com A, and On-board BMC/VSI.  
Select On-Board BMC/VSI for the console redirection option.  
d. Review the serial port settings, and ensure that the settings match the serial port communications  
software settings used to connect to LO100.  
5.  
On ProLiant ML110 G3 servers:  
a. Press the right arrow () key to navigate to the Advanced menu.  
b. Press the down arrow () key to scroll to the BIOS Serial Console Configuration menu. Press the  
Enter key. Select Bios Serial Console, and press the Enter key to toggle between Enabled and  
Disabled. Select Enabled.  
c. Press the down arrow () key to scroll to and select Serial Over LAN (SOL). Press the Enter key to  
toggle between Enabled and Disabled. Select Enabled.  
6.  
Press the Esc key to return to the previous screen, or press the F10 key to save the changes and exit  
Setup.  
Using TCP/IP over Ethernet management port  
The LO100 LAN port can be accessed from two different Ethernet ports: the dedicated 10/100 LO100  
management port or through a side-band connection with the second LOM (NIC2).  
Configuration 13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Selecting an Ethernet management port  
The Ethernet management port is only available on ProLiant ML150 G2 and ML110 G3 servers.  
To select either the LO100 or side-band connection:  
1.  
2.  
Power on the server by pressing the Power On/Off button on the front panel.  
When POST displays the message, ROM-Based Setup, press the F10 key. If the server has an  
administrator password configured, the system prompts you to enter the password. If the server does  
not have a password configured, the main screen of the BIOS Setup Utility appears.  
3.  
4.  
Press the right arrow () key to navigate to the Advanced menu.  
Press the down arrow () key to scroll to NIC Option. Press the Enter key to select between the  
dedicated or side-band connection.  
5.  
Press the Esc key to return to the previous screen, or press the F10 key to save the changes and exit  
Setup.  
The dedicated TCP/IP over Ethernet management port, whether dedicated or shared, is a standard  
Ethernet 10/100Mb interface that is connected to the network using a standard Ethernet cable. Before  
using the dedicated management port, you must determine the DHCP IP address, set a static IP address,  
or use the default static IP address.  
Obtaining a DHCP IP address from the BIOS Setup Utility  
By default, LO100 has DHCP enabled and automatically negotiates an IP address. To view the DHCP IP  
address, run the BIOS Setup Utility or retrieve the DHCP IP address using CLP through the serial port  
connection.  
To view the DHCP IP address using the BIOS Setup Utility:  
1.  
2.  
Power on the server by pressing the Power On/Off button on the front panel.  
When POST displays the message, ROM-Based Setup, press the F10 key. If the server has an  
administrator password configured, the system prompts you to enter the password. If the server does  
not have a password configured, the main screen of the BIOS Setup Utility appears.  
3.  
4.  
5.  
Press the right arrow () key to navigate to the Advanced menu.  
Press the down arrow () key to scroll to IPMI. Press the Enter key.  
On HP ProLiant ML110 G3 and ML150 G2 servers:  
a. Press the down arrow () key to scroll to the LAN Configuration (ML110 G3) submenu or LAN  
Interface (ML150 G2). Press the Enter key.  
b. Note the DHCP assigned IP address for future reference.  
6.  
7.  
On HP ProLiant DL140 G2 and ProLiant DL145 G2 servers:  
a. Press the down arrow () key to scroll to the LAN Interface submenu. Press the Enter key.  
b. Note the DHCP assigned IP address for future reference.  
Press the Esc key to return to the previous screen, or press the F10 key to save the changes and exit  
Setup.  
To configure or change your network settings, see "Network settings (on page 36)" for more information.  
Configuration 14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Setting up a static IP address from the BIOS Setup Utility  
By default, LO100 has DHCP enabled and automatically negotiates an IP address.  
To disable DHCP and enable a static IP address:  
1.  
2.  
3.  
4.  
Press the F10 key during POST to enter the BIOS Setup Utility.  
Press the right arrow () key to navigate to the Advanced menu.  
Press the down arrow () key to scroll to IPMI. Press the Enter key.  
On the ProLiant ML150 G2 server:  
a. Press the down arrow () key to scroll to the LAN Interface submenu. Press the Enter key.  
b. Select IP Address Source, and press the Enter key to toggle between Enabled and Disabled. Set  
DHCP IP Source to Disabled.  
c. Press the down arrow () key to scroll to the IP Address setting.  
d. Enter a valid IP address. Press the Tab or period (.) key to move between address fields.  
e. Press the down arrow () key to scroll down to the Subnet Mask submenu. Press the Enter key.  
f. Enter a valid subnet mask. Press the Tab or period (.) key to move between address fields.  
On the ProLiant ML110 G3 server:  
5.  
a. Press the down arrow () key to scroll to the Set LAN Configuration submenu. Press the Enter key.  
b. Select DHCP IP Source, and press the Enter key to toggle between Enabled and Disabled. Set  
DHCP IP Source to Disabled.  
c. Press the down arrow () key to scroll to the IP Address submenu. Press the Enter key.  
d. Enter a valid IP address, subnet mask, and gateway address. Press the Tab or period (.) key to  
move between address fields.  
e. Press the Esc key to return to the Set LAN Configuration submenu.  
f. Press the down arrow () key to scroll to the Subnet Mask submenu. Press the Enter key.  
g. Enter a valid subnet mask. Press the Tab or period (.) key to move between address fields.  
On the ProLiant DL140 G2 and ProLiant DL145 G2 servers:  
6.  
7.  
a. Press the down arrow () key to scroll to the LAN Settings submenu. Press the Enter key.  
b. Set the IP Address Assignment to Static. This setting enables you to modify a static IP address  
through the BIOS setup menu.  
c. Press the down arrow () key to scroll down and enter a valid IP address, subnet mask, and  
gateway address (press the Tab or period (.) key to move between address fields).  
Press the F10 key to save and exit.  
To restore DHCP, see "Configuring network settings using the BIOS Setup Utility (on page 37)."  
Enabling telnet and HTTP services  
On the ProLiant ML110 G3 server, HTTP and telnet are automatically enabled.  
To enable HTTP and telnet on ProLiant DL140 G2 and ProLiant DL145 G2 servers:  
1.  
2.  
3.  
Press the F10 key during POST to enter the BIOS Setup Utility.  
Press the right arrow () key to navigate to the Advanced menu.  
Press the down arrow () key to scroll to IPMI. Press the Enter key.  
Configuration 15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
4.  
5.  
Press the down arrow () key to scroll to the LAN Interface submenu. Press the Enter key.  
Press the down arrow () key to scroll to the following settings, and set the parameters as needed  
(the following example shows configuring for LO100 access using telnet and a web page):  
o
o
o
BMC Telnet Service: [Enabled]  
BMC Ping Response: [Enabled]  
BMC HTTP Service: [Enabled]  
To enable HTTP and telnet on ProLiant ML150 G2 servers:  
1.  
2.  
3.  
4.  
Press the F10 key during POST to enter the BIOS Setup Utility.  
Press the right arrow () key to navigate to the Advanced menu.  
Press the down arrow () key to scroll to IPMI. Press the Enter key.  
Press the down arrow () key to scroll to the following settings, and set the parameters as needed  
(the following example shows configuring for LO100 access using telnet and a web page):  
o
o
o
Ping Response: [Enabled]  
Telnet Access: [Enabled]  
HTTP Access: [Enabled]  
Updating the firmware  
To update LO100 firmware, use the ROMPaq utility. ROMPaq downloads are available on the HP  
website (http://www.hp.com/support). For more information about using the ROMPaq utility, see the HP  
NOTE: LO100 does not support ROMPaq flashing or flashing LO100 from a virtual floppy.  
NOTE: Firmware upgrade packages for ProLiant ML150 G2 servers contain firmware images  
for LO100 standard and advanced functionality. When updating the firmware, only the active  
LO100 device is flashed. If an HP Lights-Out 100c Remote Management Card is installed in  
the system when flashing the firmware, only the HP Lights-Out 100c Remote Management Card  
firmware is updated. If an HP Lights-Out 100c Remote Management Card is not installed, only  
the standard (basic) LO100 functionality is updated.  
After the ROMPaq utility flashes the selected device, cycle power manually to reboot the operating  
system.  
Updating the firmware remotely  
If you want to update the LO100 firmware remotely, you can use the loadcommand. The firmware file  
must be an uncompressed firmware image file which you can create using the DOS ROMPAQ utility  
found on the Lights-Out 100 Firmware Upgrade Diskette Utility, available for download from the HP  
To create an uncompressed image file, enter the following command at the DOS prompt:  
ROMPAQ /D <infile> <outfile>  
where <infile> is the ROMPAQ firmware image file and <outfile> is the file name for the  
uncompressed binary image file. For example:  
Configuration 16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
ROMPAQ /D cpqq0801.D14 ldrImage.bin  
ROMPAQ Firmware Upgrade Utility, Version 5.02 (R)  
Copyright (c) Hewlett-Packard Corporation, 1994-2006  
Input file: CPQQ0801.D14  
Output file: LDRIMAGE.BIN  
The loadcommand is used to take a binary image from a specific source location (specified as a URL)  
and place it at the specified target address. The loadcommand can download and flash a ldr firmware  
image file using TFTP from the specified location.  
To update the firmware, log in to LO100 as administrator through the CLP interface and issue the load  
command to upload and install the firmware from the map1/firmware directory.  
1.  
Start a CLP session. To access the CLP in Windows®:  
a. Click Start>All Programs>Accessories>Command Prompt.  
b. At the command prompt, enter telnet <IP address>where IP addressis the IP Address  
of the server to which you want to connect.  
2.  
3.  
At the CLP prompt, enter: cd/map1/firmware  
At the CLP prompt, enter load -source <URI> -oemhpfiletype csr  
where:  
o <URI>is the //tftpserver IP/path/filenameto be downloaded.  
o
o
tftp server IP is the URL or IP address of the TFTP server containing the firmware.  
filename is the file name of the image file (LdrImage.bin in this example).  
For example, enter: load -source //10.141.38.157/LdrImage.bin - oemhpfiletype  
csr  
NOTE: After using the loadcommand LO100 will reset ending your CLP interface session.  
You must reconnect to the CLP interface.  
NOTE: When you use the CLP loadcommand with TFTPD32, HP recommends using a 30-  
second timeout and 6 retries.  
TFTP settings  
When using a TFTP server, the settings vary by on different operating systems. Use the following settings:  
Flashing the firmware image file using TFTP on Microsoft Windows®  
1.  
2.  
3.  
4.  
Copy the BMC firmware into a directory on the server.  
Run TFTP by launching the executable file tftpd32.exe.  
Navigate to TFTP Configuration>Settings, and set Timeout to 30 seconds and Max Retransmit to 6.  
Enter File Name and TFTP Server IP Address. File Name is the path where the BMC firmware is  
residing. TFTP Server IP Address is the IP address of the TFTP server. For example, 10.141.38.157.  
Flashing the firmware image file using TFTP on Linux  
1.  
Navigate to Applications>Systems Settings>Server Settings>Services, and ensure that tftpand  
xinetdare running.  
Configuration 17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
2.  
3.  
Open the file /etc/xinetd.d/tftpand modify the parameter server_argsto include -T  
15000000. For example, server_args = -c -s /tftpboot -T 15000000  
The firewall that is built into some Linux systems might not allow the TFTP server to send and receive  
information. You might first have to disable the firewall to allow these connections. If you are  
experiencing firewall issues, change the firewall settings to allow connections on port 69 (the default  
port for TFTP servers). See your firewall documentation for additional information.  
If a firewall is enabled, disable it or modify the settings to allow the firewall to connect to the TFTP  
port. To change the firewall settings, navigate to Applications>System Settings>Security Level, and  
enter 69:udp in other ports.  
Configuration 18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Using LO100  
In this section  
SSL overview ......................................................................................................................................... 19  
SSH overview ........................................................................................................................................ 20  
CLP overview......................................................................................................................................... 22  
IPMI 2.0 support .................................................................................................................................... 27  
Logging in to LO100 .............................................................................................................................. 28  
Hardware Inventory page ....................................................................................................................... 30  
Controlling server power remotely............................................................................................................ 30  
Monitoring sensors................................................................................................................................. 32  
Using the system event log ...................................................................................................................... 34  
Network settings .................................................................................................................................... 36  
Using the virtual floppy feature ................................................................................................................ 38  
HP SIM support...................................................................................................................................... 46  
SSL overview  
SSL is an advanced feature that is available on ProLiant ML150 G2 and ProLiant ML110 G3 servers by  
installing the Lights-Out 100 Remote Management Card, or on ProLiant DL140 G2 servers and ProLiant  
DL145 G2 servers by purchasing the Lights-Out 100i Select Pack or the Lights-Out 100i Advanced Pack.  
SSL is a protocol used to transmit private documents through the Internet. SSL uses a private key or  
certificate to encrypt data transferred over the SSL connection. The Lights-Out 100 remote management  
processor provides strong security for remote management in distributed IT environments by using 128-bit  
SSL encryption of HTTP data transmitted across the network. SSL encryption ensures that the HTTP  
information is secure as it travels across the network.  
LO100 comes preinstalled with a certificate. To install a user-specific certificate, see the one-time  
"Importing a certificate (on page 21)" setup procedure.  
If you cannot access the login page, you must verify the SSL encryption level of your browser is set to 128  
bits. The SSL encryption level within the management processor is set to 128 bits and cannot be changed.  
The browser and management processor encryption levels must be the same.  
To use the preinstalled certificate, enter https://ipaddressin the address line of the browser, which  
uses SSL-encrypted communication. Enter http://ipaddressto use non-SSL encrypted communication.  
Using LO100 19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
SSH overview  
SSH is an advanced feature that is available on ProLiant ML150 G2 and ProLiant ML110 G3 servers by  
installing the Lights-Out 100 Remote Management Card, or on ProLiant DL140 G2 servers and ProLiant  
DL145 G2 servers by purchasing the Lights-Out 100i Select Pack or the Lights-Out 100i Advanced Pack.  
SSH is a telnet-like program for logging in to and executing commands on a remote machine, which  
includes security with authentication, encryption, and data-integrity features. The Lights-Out 100 remote  
management processor can support simultaneous access from two SSH clients. After SSH is connected  
and authenticated, the command line interface is available.  
LO100 supports the following protocols:  
SSH protocol version 2  
PuTTY 0.54, which is a free version of telnet and SSH protocols available for download on the  
Internet. When using PuTTY, versions earlier than 0.54 might display two line feeds instead on a  
single line feed, when the Enter key is pressed. To avoid this issue, and for best results, use version  
0.54 or later.  
OpenSSH, which is a free version of the SSH protocol available for download on the Internet.  
NOTE: Logging in to an SSH session could take up to 90 seconds. Depending on the client  
used, you might not see on-screen activity during this time.  
LO100 comes preinstalled with a certificate. To install a user-specific certificate, see the one-time  
"Importing a certificate (on page 21)" setup procedure.  
Using SSH  
When using a Secure Shell utility to connect to a server for the first time, the utility will prompt you to  
accept the server's public key, sometimes referred to as a host key. Accepting this key authorizes the  
utility to store a copy of the public key in its own database. The utility will automatically recognize the  
server when future connections are attempted, by comparing the public key to the one stored in its  
database.  
To access the remote management processor using SSH:  
1.  
2.  
Open an SSH window.  
When prompted, enter the IP address or DNS name, login name, and password.  
Using OpenSSH  
To start an OpenSSH client in Linux, use:  
ssh -l loginname ipaddress/dns name  
Using PuTTY  
To start a PuTTY session, double-click the PuTTY icon in the directory in which PuTTY is installed.  
To start a PuTTY session from the command line:  
o
o
o
To start a connection to a server called host:  
putty.exe [-ssh | -telnet | -rlogin | -raw] [user@]host  
For telnet sessions, the following alternative syntax is supported:  
putty.exe telnet://host[:port]/  
To start an existing saved session called sessionname:  
Using LO100 20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
o
putty.exe -load "session name"  
Importing a certificate  
If you do not want to use the preinstalled public key (certificate), create and install your own private key  
(certificate). Importing a key or certificate is a one-time procedure that supports both SSH and SSL. The  
key must be generated using external third-party software, placed on a TFTP server, and uploaded to the  
LO100. For Microsoft® Windows®, if you do not have a TFTP software package, use TFTPD32.EXE,  
which is available on the Internet. Linux generally has a TFTP server installed with the operating system. If  
it is not, see your Linux documentation for more information.  
NOTE: When you use the CLP loadcommand with TFTPD32, HP recommends using a 30-  
second timeout and 6 retries.  
NOTE: When using the CLP loadcommand in Linux set the timeout to 15000000. The  
firewall built into some Linux systems might not allow the TFTP server to send and receive  
information. You might have to disable the firewall to allow these connections. If you are  
experiencing firewall issues, change the firewall settings to allow connections on port 69 (the  
default port for TFTP servers). See your firewall documentation for additional information.  
Creating a certificate  
LO100 requires a 1,024-bit DSA key stored in PEM (Base64-encoded) format to be located on a TFTP  
server. For example, the following process uses Win32 OpenSSL, downloaded from the Shining Light  
issued in a DOS window to generate the certificate. To generate a certificate using Win32 OpenSSL:  
1.  
2.  
3.  
Download Win32 OpenSSL.  
Install and set up OpenSSL.  
Using OpenSSL, generate a DSA parameters file:  
openssl dsaparam -out server_dsaparam.pem 1024  
4.  
5.  
Generate the DSA private key file, called server_privkey.pem:  
openssl gendsa -out server_privkey.pem server_dsaparam.pem  
Generate the DSA certificate (public key) file, called server cacert.pem:  
openssl req -new -x509 -key server_privkey.pem -out server_cacert.pem -  
days 1095  
6.  
7.  
When prompted for a distinguished name, enter an appropriate domain name for the servers  
receiving the certificate.  
After creating the certificate, copy it to a TFTP server that is accessible on the same network as  
LO100.  
Installing a certificate or private key through the CLP  
To install the certificate, log in to LO100 as administrator through the CLP interface and issue the load  
command to upload and install the certificate. For example:  
load -source <URI> -oemhpfiletype cer  
where:  
Using LO100 21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
o <URI>is the //tftpserver IP/path/filenameto be downloaded.  
tftpserver is the URL or IP address of the TFTP server containing the certificate.  
o Pathis the path of the file relative to the TFTP server root.  
filename is the name of the certificate (server_privkey.pemin this example).  
o
o
You can also find these commands in /map1/firmware directory.  
To install a private key, log in to LO100 as administrator through the CLP interface, and issue the load  
command to upload and install the certificate. For example:  
load -source <URI> -oemhpfiletype key  
where:  
o <URI>is the //tftpserver IP/path/filenameto be downloaded.  
o
tftpserver is the URL or IP address of the TFTP server containing the private key file.  
o Pathis the path of the file relative to the TFTP server root.  
filename is the file name of the private key file (server_privkey.pemin this example.)  
o
You can also find these commands in /map1/firmware directory.  
NOTE: After using the loadcommand LO100 will reset ending your CLP interface session.  
You must reconnect to the CLP interface.  
CLP overview  
HP has worked with key industry partners within Distributed Management Task Force, Inc. to define an  
industry-standard set of commands. The SMASH suite will standardize manageability interfaces for  
servers. The Lights-Out 100 remote management processor implements the command set defined in the  
Server Management Command Line Protocol Specification, 1.00 Draft. The CLP replaces the simple CLI  
that was released previously and is no longer supported.  
The management processor functionality accessible from the SMASH CLP is a low-bandwidth interface  
and provides similar functionality to the web interface. The CLP is designed for users who prefer a  
nongraphical interface. The CLP is accessible through the following methods:  
Telnet  
SSH connection  
Physical serial port  
Using CLP  
The general syntax of CLP command is:  
<verb> <target> <option> <property>  
Verbs—The following verbs are supported:  
o cd  
o help  
o load  
o reset  
o set  
Using LO100 22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
o show  
o start  
o stop  
o exit  
o version  
Target—The default target is the /. The target can be changed by the cdcommand or by specifying  
a target on the command line.  
Options—The following options are valid:  
o -help/-h  
o -all/-a  
Properties are the attributes of the target that can be modified.  
Output—The output syntax is text.  
The valid Boolean values for any command are trueand false.  
General notes  
If the commands on the CLP command span more than one line, you cannot navigate between different  
lines.  
Operating system-specific notes  
The Microsoft® Windows® 2000 telnet client does not support the Functions keys F1 through F12,  
Insert, Home, and End keys. These keys will not work in a Lights-Out 100 command line session.  
The Backspace key in the Lights-Out 100 CLP implementation is mapped to the value 0x8. Some  
client operating systems, Novell Linux Desktop and Red Hat Enterprise Linux 4 Desktop, map the  
Backspace key to the value 0x7f,which is used for the Delete key in the Windows® telnet client.  
The Backspace key will not work from a client from which it has value of 0x7f. For the Linux clients,  
using the Home or the End key enables the Lights-Out 100 CLP service to remap the Backspace key  
to use the value 0x7f, making the key functional.  
In the Windows® PuTTY client, the Backspace key can be mapped to a value of 0x8by changing the  
setting for Terminal Keyboard to Control-H.  
Base commands  
The helpcommand displays context-sensitive help.  
Entering helpdisplays all the supported commands. Entering <command help/?>displays the  
help message specific to that command.  
o
Help for verbs  
Calling help for a verb returns the general syntax and usage associated with issuing that verb.  
Calling help for a verb that is not present in the current directory returns an Unsupported  
Commandmessage. The following are all valid ways to call help for a verb.  
/./-> help show  
Usage: show [<target>][<options>][<properties>]  
/./-> show -h  
Usage: show [<target>][<options>][<properties>]  
Using LO100 23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
/./-> show -help  
Usage: show [<target>][<options>][<properties>]  
/./->  
o
Help for targets  
Calling help for a target returns any information about the target and what it contains. You can  
call help for any target that is not contained in the current directory (help map1can be called  
from system1).  
/./-> system1 -h  
Invalid command  
/./-> system1 -help  
Invalid command  
/./-> help system1  
Host System Directory  
/./-> help map1  
Management Service Processor Directory  
/./-> cd system1  
/./system1/-> help map1  
Management Service Processor Directory  
o
Help for properties  
Calling help for a property or any other option for which there is no help information returns an  
Unsupported Commandor Invalid commandmessage. For example:  
/./system1/-> show  
/./system1  
Targets  
log1  
Properties  
name=Hewlett-Packard  
enabledstate=enabled  
Verbs  
cd  
version  
exit  
show  
reset  
start  
Using LO100 24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
stop  
help  
/./system1/-> help name  
Unsupported Command  
/./system1/-> help enabledstate  
Unsupported Command  
/./system1/-> help properties  
Unsupported Command  
/./system1/-> name -h  
Invalid command  
/./system1/->  
The exitcommand terminates the CLP session.  
The cdcommand sets the current default target. The context works like a directory path. The root  
context for the server is /.which is the starting point for a CLP system. By changing the context, you  
can shorten commands.  
For example:  
o cdchanges the directory.  
o cd ..moves up the tree one directory.  
o cd foldermoves to folder assuming folder is in the current directory.  
If you want to move to a directory not in the current directory, you must enter the full path. Root in  
the command line is /./  
If you are in system1 and want to move to map1, issue the command cd /./map1. Neither cd  
/map1nor cd map1works. The filename is not case-sensitive, whereas the command is case-  
sensitive (cd MaP1works while CD map1does not).  
The showcommand displays values of a property or contents of a collection target. For example:  
/./> show  
/./  
Targets  
system1/  
map1/  
Properties  
Verbs  
cd  
version  
exit  
show  
help  
Using LO100 25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
The first line of information returned by the showcommand is the current context. In the example, /  
is the current context. Following the context is a list of subtargets (Targets) and properties (Properties)  
applicable to the current context. The verbs (Verbs) section shows what commands are available in  
this context.  
The showcommand can also be specified with an explicit or implicit context and a specific  
property. An explicit context is /map1/firmwareand is not dependent on the current context. An  
implicit context assumes that the context specified is a child of the current context. If the current  
context is /map1, then a show firmwarecommand displays the /map1/firmware data. If a  
property is not specified, then all properties are shown.  
The loadcommand moves a binary image from a URL to the map. The loadcommand is used to  
take a binary image from a specific source location (specified as a URL) and place it at the specified  
target address. In a remote management processor implementation, the firmware downloads a full  
image file using TFTP from the specified location and programs flash with the image.  
In a remote management processor implementation, /map1/firmwareis a valid target.  
The loadcommand supports usage only with the following options.  
o -source <location>—This option must be specified.  
o (h)elp—this option appears on the command line, the command ignores all options and  
properties except -output(for terse or verbose output). These options are only valid for this  
command when the -helpoption is used.  
o source <value>—This option specifies the target from which it will transfer the binary image.  
The value specified must be a valid URL. The expected format is  
//tftpserverip/path/filename. This option is required in the command line every time  
the load command is executed unless -helpis used. The file must be an uncompressed firmware  
image file that you create using the DOS ROMPAQ utility found on the Lights-Out 100 Firmware  
Upgrade Diskette Utility available for download from the HP website  
To create the uncompressed image file, enter the following command from DOS:  
ROMPAQ /D <infile> <outfile>  
where <infile> is the ROMPAQ firmware image file and <outfile>is the filename for the  
uncompressed binary image file.  
The loadcommand returns any status data on the first lines. After the status data appears, one of  
the following lines of text displays on the next line:  
<URL> transferred to <target address> (if the file is transferred)  
<URL> not transferred(if the file is not transferred)  
Example:  
load -source //192.168.2.1/pub/firmwareimage.bin -oemhpfiletype csr  
//192.168.2.1/pub/firmwareimage.bin transferred to  
/map1/firmware/fullimage  
The resetcommand causes a target to cycle from enabled to disabled and back to enabled.  
The setcommand sets a property or set of properties to a specific value. set property = new  
valueis the standard syntax for the set command.  
The set command is used to change any changeable property. If the current directory does not  
contain the property you want to change, the target of the property must be specified before entering  
the property you want to change.  
Using LO100 26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
The startcommand causes a target to change state to a higher run level.  
The stopcommand causes a target to change state to a lower run level.  
The versioncommand queries the version of the CLP implementation or other CLP elements. For  
example:  
/./map1/-> version  
Version 1.00  
/./map1/-> cd firmware  
/./map1/firmware/-> version  
Version 1.00  
/./map1/firmware/-> show  
/./map1/firmware  
Targets  
Properties  
fwversion=0.59  
Verbs  
cd  
version  
exit  
show  
reset  
load  
help  
/./map1/firmware/-> show fwversion  
fwversion=0.59  
/./map1/firmware/-> fwversion  
Invalid command  
/./map1/firmware/->  
Specific commands  
CLP syntax for specific commands is found in the sections that also describe the functionality through the  
Web interface.  
IPMI 2.0 support  
LO100 supports the industry-standard IPMI 2.0. The IPMI specification defines standardized, abstracted  
interfaces that can be used for monitoring and control functions that are built in to the platform hardware.  
In addition to supporting the mandatory commands for IPMI 2.0, the following additional IPMI 2.0  
features are supported by LO100:  
Additional IPMI 2.0 commands  
o
o
o
Get Channel Cipher Suites  
Set/Get Channel Security Keys  
Suspend/Resume Payload Encryption  
Using LO100 27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Payload types  
o
o
o
o
IPMI Message  
RMCP+ Open Session Request/Response  
RAKP Message 1 / 2  
RAKP Message 3 / 4  
Authentication algorithms  
o
o
RAKP-none  
RAKP-HMAC-SHA1  
Integrity algorithms  
o
o
None  
HMAC-SHA1-96  
Confidentiality algorithms  
o
o
None  
AES-CBC-128  
Logging in to LO100  
You can log in to the remote management processor through a web browser ("Logging in through a web  
browser" on page 28) or through the CLP ("Logging in through the CLP" on page 29). If you are unsure of  
your DHCP IP address, refer to the "Configuring network access (on page 11)" section.  
Logging in through a web browser  
1.  
2.  
Browse to the IP address of the remote management processor to access the login screen.  
Enter your user name and password. The default user name for the Administrator account is admin,  
and the default password is admin. The default user name for the Operator account is Operator,  
and the default password is Operator.  
Using LO100 28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Logging in through the CLP  
To log in to the remote management processor through the CLP and enter Terminal mode:  
1.  
2.  
3.  
Establish a connection to the remote management processor by launching a telnet session or an SSH  
session.  
Enter the user name at the login: prompt. The default user name for the Administrator account is  
admin. The default user name for the Operator account is Operator.  
Enter the password at the password: prompt. The default password for the Administrator account is  
admin. The default password for the Operator account is Operator.  
To exit the CLP and enter Console mode, enter the exitcommand at the command prompt.  
Browser main menu options  
The main menu provides access to all basic remote management capabilities of the remote management  
processor.  
Option  
Description  
Home  
Accesses or returns you to the main menu  
navigation bar  
Virtual Power  
Accesses system power control options  
Monitoring Sensors  
Lists all sensor information, including type,  
name, status, reading, and PEF settings  
System Event Log  
Virtual Floppy  
Displays the system event log  
Accesses the virtual floppy screen  
Displays system hardware  
Hardware Inventory  
User Administration  
Network Settings  
Accesses the user configuration screen  
Accesses the network parameter settings  
screen  
Using LO100 29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Option  
Description  
IPMI PET Configuration Accesses the PET destinations and alert policy  
table  
Hardware Inventory page  
The Hardware Inventory page enables you to remotely identify the presence of processors on a target  
server. To access this page from a web browser, click Hardware Inventory on the main menu navigation  
bar.  
Controlling server power remotely  
LO100 enables you to remotely operate the power button of a host server using a web browser or the  
CLP. LO100 virtual power support enables you to power up, power down, and power cycle the host  
server. This virtual power support operates independently of the state of the operating system.  
Using LO100 30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Controlling server power from a browser  
The Virtual Power screen displays current power status, how long the server has been powered up, and  
reason for the last server restart. To display the Virtual Power screen, click Virtual Power on the main  
menu navigation bar.  
To modify Chassis Actions, select the desired Power Control Option in the Chassis Actions section, and  
click Apply to initiate the action.  
To identify the server in the rack and illuminate the UID (LED on the front panel of the server), select the  
length of time you want the UID to stay illuminated on the Chassis Locator list, and click Identify.  
NOTE: The UID is only available on HP ProLiant DL140 G2 and ProLiant DL145 G2 servers.  
Controlling server power through the CLP  
1.  
2.  
3.  
Log in to LO100 CLP as described in the "Logging in to LO100 (on page 28)" section.  
Change to the system1 target by entering cd system1.  
To power on the server, enter start /system1. For example:  
/./system1/> start /system1  
System1 started.  
4.  
To power off the server, enter stop /system1. For example:  
/./system1/> stop /system1  
System1 stopped.  
The -forceoption can also be used with the stopcommand. This option forces the  
implementation to stop the target, ignoring any policy that might cause the implementation to  
normally not execute the command. In remote management processor implementation, this process is  
equivalent to a hard power down.  
5.  
To reset the server, enter reset /system1. For example:  
/./system1/> reset  
System1 reset.  
Using LO100 31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Controlling server power through the BIOS Setup Utility  
To control how the system responds after a power failure through the BIOS Setup Utility:  
1.  
2.  
3.  
4.  
Press the F10 key during POST to enter the BIOS Setup Utility.  
Press the right arrow () key to navigate to the Power Tab of the BIOS Setup Utility.  
Press the down arrow () key to scroll down to After Power Failure. Press the Enter key.  
On the ProLiant ML150 G2, or ML110 G3 servers: Use the arrow keys to navigate between Stay  
Off, Last State, and Power On. Select your power control option, and press the Enter key.  
5.  
On ProLiant DL140 G2 or ProLiant DL145 G2 servers: Use the arrow keys to navigate between  
Always Off, Previous State, and Always On. Select your power control option, and press the Enter  
key.  
6.  
Press the F10 key to save and exit.  
Monitoring sensors  
LO100 provides operating system-independent remote monitoring of the current status of major sensors of  
a target server including system temperature, fans, and voltage. You can view the data for this feature on  
the Monitoring Sensors Page through a web browser or through the BIOS Setup Utility.  
Viewing sensors data from a web browser  
The Monitoring Sensors screen displays a snapshot of the temperature, fans, and voltage sensor data  
including sensor type, name, status, and current reading. To access this page from a web browser, click  
Monitoring Sensors on the main menu navigation bar.  
To update the display, click the Refresh button on the web browser. To view or add a PEF action, click  
PEF. See "Platform Event Filtering configuration (on page 33)" for more information.  
Viewing sensors data from the BIOS Setup Utility  
1.  
Press the F10 key during POST to enter the BIOS Setup Utility.  
Using LO100 32  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
2.  
3.  
On ProLiant ML150 G2 servers:  
a. To navigate to the Monitor menu, press the right arrow () key.  
b. Scroll down to view the different sensors. Data is real-time and updated periodically.  
On ProLiant DL140 G2 and ProLiant DL145 G2 servers:  
a. Press the right arrow () key to navigate to the Advanced menu.  
b. Press the down arrow () key to scroll to IPMI. Press the Enter key.  
c. Press the down arrow () key to scroll to Realtime Sensor Data. Press the Enter key.  
The Loading data. Please waitmessage appears. After this message disappears, the  
Temperature and Voltage sensor data appears. Data is displayed in real-time and updated  
periodically.  
4.  
On the ProLiant ML110 G3 server:  
a. Press the right arrow () key to navigate to the Advanced menu.  
b. Press the down arrow () key to scroll to Hardware Health Configuration menu. Press the Enter  
key. The real-time sensor data displays.  
Platform event filtering configuration  
The PEF Configuration screen enables you to configure LO100 to take selected actions on received or  
internally generated event messages. These actions include powering down the system, system reset, and  
triggering the generation of an alert.  
To configure a PEF for a particular sensor, click the PEF button to the far right of that sensor on the  
Monitoring Sensors screen. The PEF button adjacent to each sensor opens a PEF Configuration page for  
that sensor.  
The PEF Configuration screen contains two sections: Current PEF Entries and Add PEF Entry. The Current  
PEF Entries section includes Sensor Type, Sensor Name, PEF Action, and PEF Control information. The  
Add PEF Entry section enables you set an action.  
Initially, there are no entries in the Current PEF Entries section because no PEFs are defined. When PEF  
entries are defined, the PEF Control field is active and allows individual entries to be enabled, disabled,  
or deleted.  
Using LO100 33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
To configure an action (PEF entry) select the desired Event Offsets and PEF Action settings and click Add.  
Event Offsets are trip points (movements across thresholds) that define what type of sensor event  
triggers an action. The information in the Events Offsets section varies with the type of sensor. Not all  
options are available for all sensors. You can select any of the available options.  
PEF Action displays the same information for all sensors:  
o
o
o
Sensor Type displays the type of sensor selected.  
Sensor Name displays the name of the sensor.  
PEF Action enables you to select from Power Off, Power Cycle, Hard Reset, and Send Alert  
(requires a systems management console supporting IPMI 1.5 or later.)  
o
o
PEF Control enables or disables the sensor.  
Alert Policy (dropdown list adjacent to the Add button) enables you to select an alert policy (if  
defined.) Alert policies are defined on the PET Configuration screen. See "Platform event trap  
configuration (on page 41)" for more information.  
If alert policies are not defined (default), the Alert Policy dropdown list displays No Alert Policy.  
The Alert Policy dropdown list will populate after alert policies are defined and configured. After  
configuring your alert policies, you can select from the defined alert policies for this sensor and  
PEF.  
o
Add adds the new entry to the PEF Current Entry table at the top of the page.  
Using the system event log  
LO100 captures and stores the IPMI event log for access through a browser, CLP, BIOS Setup Utility, and  
RBSU even when the server is not operational. The system event log lists a short description of each  
system event. Recorded events include abnormal temperature, fan and voltage events, system resets,  
system power loss, user login, and unsuccessful login attempts.  
Accessing the system event log from a web browser  
The System Event Log screen displays a brief description of the event including event type, date, time,  
source, description, and direction.  
Using LO100 34  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
To access the System Event Log from a web browser, click System Event Log on the main menu navigation  
bar. To clear the system event log, click Clear Event Log.  
Accessing the system event log from the CLP  
1.  
2.  
3.  
4.  
Log in to the CLP as described in the "Logging in to LO100 (on page 28)" section.  
Enter cd /./system1/log1  
Enter showto display the total number of system event records.  
Enter show record<n>to display the details of a specific record. For example:  
/system1/log1/record1  
Targets  
Properties  
number=1  
date=12/20/2004  
time=15:22:05  
sensordescription= Backplane +12V  
eventdescription= Upper Critical-going high  
eventdirection=Assertion  
Verbs  
cd  
version  
exit  
show  
reset  
oemhp  
help  
Accessing the system event log from the BIOS Setup Utility  
1.  
2.  
3.  
4.  
Press the F10 key during POST to enter the BIOS Setup Utility.  
Press the right arrow () key to navigate to the Advanced menu.  
Press the down arrow () key to scroll to IPMI. Press the Enter key.  
On ProLiant DL140 G2 and ProLiant DL145 G2 servers:  
a. Press the down arrow () key to scroll to System Event log submenu. Press the Enter key.  
b. Press the down arrow () key to scroll the following setup options: Clear System Event Log and  
View System Event Log.  
If you select View System Event log, use the PG UP, PG DOWN keys, or spacebar to scroll  
through the entries.  
5.  
6.  
On ProLiant ML150 G2 servers:  
a. Press the down arrow () key to scroll to the System Event log submenu. Press the Enter key.  
b. Press the down arrow () key to scroll to through the following setup options including Date  
Format to show, Date Separator, System Event Logging, Sys Firmware Progress, and BIOS POST  
Errors.  
On ProLiant ML110 G3 servers:  
Using LO100 35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
a. Press the down arrow () key to scroll to the View BMC System Event Log submenu. Press the  
Enter key.  
b. Use the plus (+) or minus (-) keys to scroll through the events.  
7.  
Press the Esc key to return to the previous screen, or press the F10 key to save the changes and exit  
Setup.  
Network settings  
You can view and modify network settings for LO100 using a web browser, CLP, or the BIOS Setup  
Utility. If you change the IP address, the connection to the server terminates. You must reconnect to the  
server using the new IP address.  
Configuring network settings using a web browser  
The Network Settings screen displays IP address, subnet mask, and other TCP/IP-related settings. From the  
Network Settings screen, you can enable or disable DHCP, and you can configure a static IP address for  
servers not using DHCP. You can view and modify the network settings when logged in as either OEM or  
administrator (admin).  
To modify the network settings, click Network Settings on the browser main menu navigation bar, enter  
the new settings, and click Apply.  
Configuring network settings using the CLP  
1.  
2.  
3.  
Log in to LO100 CLP as described in the "Logging in to LO100 (on page 28)" section.  
At the command prompt, enter cd map1/nic1.  
Configure the network settings by entering the following: set <network property>=<new  
setting>. Configurable valid network properties are:  
o networkaddressspecifies the IP address for the NIC. This setting is dynamic.  
o oemhp_nonvol_networkaddressspecifies the IP address stored in non-volatile memory.  
o oemhp_maskspecifies the subnet mask for NIC. This setting is dynamic.  
Using LO100 36  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
o oemhp_nonvol_maskspecifies the subnet mask stored in non-volatile memory.  
oemhp_gateway specifies the gateway IP address for the NIC. This setting is dynamic.  
o
o oemhp_nonvol_gatewayspecifies the gateway IP address stored in non-volatile memory.  
o oemhp_dhcp_enablespecifies whether DHCP is enabled for the NIC. Boolean values are  
accepted  
o oemhp_nonvol_dhcp_enablespecifies whether DHCP is enabled for the NIC and address  
stored in non-volatile memory.  
Configuring network settings using the BIOS Setup Utility  
To enable a static IP address:  
1.  
2.  
3.  
4.  
Press the F10 key during POST to enter the BIOS Setup Utility.  
Press the right arrow () key to navigate to the Advanced menu.  
Press the down arrow () key to scroll to IPMI. Press the Enter key.  
On the ProLiant ML150 G2 server:  
a. Press the down arrow () key to scroll to the LAN Interface submenu. Press the Enter key.  
b. Select IP Address Source, and press the Enter key to toggle between Enabled and Disabled. Set  
DHCP IP Source to Disabled.  
c. Press the down arrow () key to scroll to the IP Address setting.  
d. Enter a valid IP address. Press the Tab or period (.) key to move between address fields.  
e. Press the down arrow () key to scroll down to the Subnet Mask submenu. Press the Enter key.  
f. Enter a valid subnet mask. Press the Tab or period (.) key to move between address fields.  
On the ProLiant ML110 G3 server:  
5.  
a. Press the down arrow () key to scroll to the Set LAN Configuration submenu. Press the Enter key.  
b. Select DHCP IP Source, and press the Enter key to toggle between Enabled and Disabled. Set  
DHCP IP Source to Disabled.  
c. Press the down arrow () key to scroll to the IP Address submenu. Press the Enter key.  
d. Enter a valid IP address, subnet mask, and gateway address. Press the Tab or period (.) key to  
move between address fields.  
e. Press the Esc key to return to the Set LAN Configuration submenu.  
f. Press the down arrow () key to scroll to the Subnet Mask submenu. Press the Enter key.  
g. Enter a valid subnet mask. Press the Tab or period (.) key to move between address fields.  
On the ProLiant DL140 G2 and ProLiant DL145 G2 servers:  
6.  
7.  
a. Press the down arrow () key to scroll to the LAN Settings submenu. Press the Enter key.  
b. Set the IP Address Assignment to Static. This setting enables you to modify a static IP address  
through the BIOS setup menu.  
c. Press the down arrow () key to scroll down and enter a valid IP address, subnet mask, and  
gateway address (press the Tab or period (.) key to move between address fields).  
Press the F10 key to save and exit.  
To enable a DHCP assigned address:  
1.  
Press the F10 key during POST to enter the BIOS Setup Utility.  
Using LO100 37  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
2.  
3.  
4.  
Press the right arrow () key to navigate to the Advanced menu.  
Press the down arrow () key to scroll to IPMI. Press the Enter key.  
On the ProLiant ML150 G2 server:  
a. Press the down arrow () key to scroll to the Set LAN Interface submenu. Press the Enter key.  
b. Select DHCP IP Source, and press the Enter key to toggle between Enable and Disabled. Select  
Enabled.  
5.  
On the ProLiant ML110 G3 server:  
a. Press the down arrow () key to scroll to the Set LAN Configuration submenu. Press the Enter key.  
b. Select DHCP IP Source, and press the Enter key to toggle between Enable and Disabled. Select  
Enabled.  
6.  
7.  
On HP ProLiant DL140 G2 and ProLiant DL145 G2 servers:  
a. Press the down arrow () key to scroll to the LAN Settings submenu. Press the Enter key.  
b. Set the IP Address Assignment to DHCP.  
Press the F10 key to save and exit.  
On the ProLiant ML110 G3 server, HTTP and telnet are automatically enabled.  
To enable HTTP and telnet on ProLiant DL140 G2 and ProLiant DL145 G2 servers:  
1.  
2.  
3.  
4.  
5.  
Press the F10 key during POST to enter the BIOS Setup Utility.  
Press the right arrow () key to navigate to the Advanced menu.  
Press the down arrow () key to scroll to IPMI. Press the Enter key.  
Press the down arrow () key to scroll to the LAN Interface submenu. Press the Enter key.  
Press the down arrow () key to scroll to the following settings, and set the parameters as needed  
(the following example shows configuring for LO100 access using telnet and a web page):  
o
o
o
BMC Telnet Service: [Enabled]  
BMC Ping Response: [Enabled]  
BMC HTTP Service: [Enabled]  
To enable HTTP and telnet on ProLiant ML150 G2 servers:  
1.  
2.  
3.  
4.  
Press the F10 key during POST to enter the BIOS Setup Utility.  
Press the right arrow () key to navigate to the Advanced menu.  
Press the down arrow () key to scroll to IPMI. Press the Enter key.  
Press the down arrow () key to scroll to the following settings, and set the parameters as needed  
(the following example shows configuring for LO100 access using telnet and a web page):  
o
o
o
Ping Response: [Enabled]  
Telnet Access: [Enabled]  
HTTP Access: [Enabled]  
Using the virtual floppy feature  
The virtual floppy feature enables you to boot the server with a boot image residing on a remote server.  
To boot using a virtual floppy on a remote system:  
1.  
Using LO100 38  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
2.  
3.  
Configure the virtual floppy on the server using one of the following methods:  
o
o
o
Configuring the TFTP Server  
The virtual floppy feature enables you to boot the server with a boot image residing on a remote server.  
To boot using a virtual floppy on a remote system:  
1.  
Install a TFTP server on a remote system and ensure that it is running. (TFTP servers are typically  
included with Linux and are available for other operating systems as well. Consult your TFTP server  
documentation for further details. If you do not have a TFTP software package, use TFTPD32.EXE,  
which is available on the Internet.)  
2.  
Create the remote boot image of the boot floppy using flimage.exe. The flimage.exeutility  
application is used to create a binary image of a 1.44-MB floppy disk. The floppy image is stored  
as 80 sequentially-numbered binary files starting with 0. Each file represents the contents of the  
corresponding cylinder from the floppy disk. You can find flimage.exeon the HP website  
3.  
4.  
Place the boot image in a subfolder (for this example, rboot is the folder containing the boot image)  
under the folder where the TFTP server executable program resides. For example, if the TFTP server  
program TFTP.exe is in C:\tftp, then place the boot image in the folder c:\tftp\rboot.  
Launch the executable file TFTP.exe and run TFTP.  
Configuring virtual floppy from a Web browser  
1.  
Log in to the remote management processor as described previously in the "Logging in to the remote  
management processor ("Logging in to LO100" on page 28)" section.  
2.  
3.  
4.  
Click the Virtual Floppy link from the main menu navigation bar.  
Enter the IP address of the TFTP server that you configured in the previous section.  
Enter the path to the folder containing the floppy boot image. This path is relative to where the TFTP  
server program TFTP.exe resides. For example, if the TFTP server program TFTP.exe is in C:\tftp and  
the floppy boot image is in the folder c:\tftp\rboot, then the path would be rboot.  
Using LO100 39  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
5.  
Click the Apply button.  
Configuring the virtual floppy from the BIOS setup  
1.  
2.  
3.  
4.  
5.  
6.  
7.  
On the target server, press the F10 key during POST to enter BIOS setup.  
In the BIOS Setup Utility, press the right arrow () key to navigate to the Advanced menu.  
Press the down arrow () key to scroll to IPMI. Press the Enter key.  
Press the down arrow () key to scroll to VSI configuration. Press the Enter key.  
Select Virtual Floppy, and press the Enter key.  
Select Enabled.  
Press the down arrow () key to scroll to TFTP Server IP Address, and enter the IP address of the TFTP  
server that you configured in the "Configuring the TFTP server (on page 39)" section of this guide.  
8.  
9.  
Press the down arrow () key to scroll to Floppy Timeout to change the default value.  
Press the down arrow () key to scroll to Image Directory Name. Press the Enter key.  
10. In the Enter new Address Path box, enter the path to the folder containing the floppy boot image.  
This path is relative to where the TFTP server program, TFTP.exe, resides. For example, if TFTP.exe is  
in C:\tftp and the floppy boot image in C:\tftp\rboot, then the path would be rboot.  
11. Press the F10 key to save the changes and exit Setup.  
Configuring virtual floppy from the CLP  
1.  
Open a CLP window on the remote system, and enter cd map1/nic1at the command prompt.  
2.  
Configure the TFTP server path by entering the following: set oemhp_vsi_tftpserver=<path>  
where <path>is the remote TFTP server IP address. For example:  
set oemhp_vsi_tftpserver=10.12.52.142  
3.  
Configure the VSI path by entering the following: set oemhp_vsi_path=<path>, where <path> the  
path to the folder containing the floppy boot image. This path is relative to where the TFTP server  
program TFTP.exe resides. For example, if the TFTP server program TFTP.exe is in C:\tftp and the  
floppy boot image in the folder c:\tftp\rboot, then the path would be rboot. For example:  
Using LO100 40  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
set oemhp_vsi_path=rboot  
4.  
Configure the remote file permission by entering the following: set  
oemhp_vsi_permission=<permission>, where <permission> is the file permission default RW (Read  
Write.) For example:  
set oemhp_vsi_permission=rw  
Rebooting the server  
After the TFTP server and the virtual floppy are properly configured, the server can be rebooted using the  
remote floppy boot image that resides on the TFTP server. The methods for rebooting the server are  
described in "Controlling server power remotely (on page 30)." The server continues to reboot to the  
virtual floppy until the virtual floppy is disabled using the following procedure:  
1.  
2.  
3.  
4.  
5.  
6.  
7.  
8.  
Ensure the target server is configured for network access. See "Network settings (on page 36)."  
Press the F10 key during POST to enter the BIOS Setup Utility.  
Press the right arrow () key to navigate to the Advanced menu.  
Press the down arrow () key to scroll to IPMI. Press the Enter key.  
Press the down arrow () key to scroll to VSI Configuration. Press the Enter key.  
Select Virtual Floppy, and press the Enter key.  
Select Enabled.  
Press the F10 key to save and exit.  
Platform event trap configuration  
The PET Configuration screen enables you to set an alarm or specified condition originating on the server  
to alert an IPMI 2.0 supported systems management console. To access this page from a browser, click  
PET Configuration on the main menu navigation bar.  
The PET Destinations section indicates where LO100 sends the PET (if configured.) This section has up to  
four entries specifying IP and MAC addresses. Enter either an IP address or a MAC address and click  
Apply. If both the a MAC and an IP address are entered, the IP address is used.  
Using LO100 41  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
To set a policy, do the following:  
1.  
Select the Policy Enable state and enter the Policy Number and Destination Selector information.  
o
o
o
The Policy Enable field enables you to selectively enable and disable trap forwarding.  
The Policy Number field enables you to select a policy that will be used in PEF configuration.  
The Destination Selector field specifies where to send the PET trap from the destinations defined  
in the PET Destination section.  
2.  
Click Apply.  
User administration  
The User Configuration option on the main menu navigation bar enables you (if authorized) to edit the  
username and password for existing users. You must be logged in as a user with administrative privileges  
to modify the user configuration. You cannot create a new user. The user password is stored in nonvolatile  
memory and can be changed through a web browser ("Changing user settings through a web browser"  
When using CLP, if you do not have the correct privileges you are not prompted to log in with the correct  
credentials. You are warned if you have insufficient access. If you receive a warning message, you must  
end the telnet connection and re-establish a connection. There are no restrictions when logged in as  
administrator (admin). The second user always has the administrator privilege. User and operator  
accounts have the following access:  
Option  
User  
Yes  
Operator  
Yes  
Hardware Inventory  
Virtual Power  
No  
Yes  
Monitoring Sensors  
System Event Log  
View only  
Yes  
Yes  
Yes  
Network Settings  
No  
No  
No  
No  
No  
No  
IPMI PET Configuration  
User Configuration  
Changing user settings through a web browser  
The User Configuration screen displays user information and enables you to modify user settings. To  
access the User Configuration screen through a web browser, click User Configuration on the main menu  
navigation bar.  
To modify user settings, do the following:  
1.  
2.  
3.  
Click User Configuration on the main menu navigation bar.  
Enter the password in the Password and Confirm Password fields.  
Select the User Privilege level from the dropdown list. See "User administration (on page 42)" for  
more information on user privileges and access rights.  
4.  
5.  
Change the user name if needed.  
Click the Set button to save the changes.  
Using LO100 42  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Changing user settings through the CLP  
1.  
2.  
3.  
4.  
Log in to the CLP as described in the "Logging in to LO100 (on page 28)" section.  
At the command prompt, enter cd map1/accounts.  
Select a user by entering cd user1or cd user2.  
To change the user name, enter set username=<new username>. For example:  
/./map1/accounts/user1/> set username=testuser1  
5.  
To change the user password, enter set password=<new password>and enter the new  
password when prompted. For example:  
/./map1/accounts/user1/> set password=testpswd1  
Passwords are case-sensitive and can contain up to 16 characters.  
6.  
To change the group name enter, set group=<new group name>. Valid group settings are  
admin, user, OEM, and operator. For example:  
/./map1/accounts/user1/> set group=user  
Accessing the remote console through telnet  
You can access the remote console through either the BIOS console text-redirection functionality or a  
Microsoft® Windows Server™ 2003 text-based console. Only one Remote Console window can be open  
at a time.  
To start a remote console session, press the Esc+Q keys. To end a remote console session and return to the  
CLP press the Esc+( keys.  
BIOS console text redirection through telnet  
BIOS console text-redirection functionality enables you to view the entire boot process remotely and make  
changes in the BIOS Setup Utility from a remote computer. This tool is valuable in troubleshooting and  
managing servers remotely.  
To configure the BIOS Setup Utility on the target system:  
1.  
2.  
3.  
Press the F10 key during POST to enter the BIOS Setup Utility.  
Press the right arrow () key to navigate to the Advanced menu.  
On ProLiant ML110 G3 servers:  
a. Press the down arrow () key to scroll down to the BIOS Serial Console Configuration option, and  
press Enter.  
b. Verify the following settings:  
BIOS Serial Console: Enabled  
Serial Over LAN (SOL): Enabled  
4.  
On ProLiant DL140 G2 and ProLiant DL145 G2 servers, press the down arrow () key to scroll down  
to the Console Redirection option, and press the Enter key to access the submenu.  
Verify the following settings:  
o
o
o
Console Redirection: Enabled  
Baud Rate: 9600  
Terminal Type: VT100+  
Using LO100 43  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
o
o
Flow Control: None  
Redirection After BIOS POST: On  
5.  
On HP ProLiant ML150 G2 servers, press the down arrow () key to scroll down to the Console  
Redirection option, and press the Enter key to access the submenu.  
Verify the following settings:  
o
o
o
o
Baud Rate: 9600  
Console Type: VT100+  
Flow Control: None  
Continue C.R. after POST: On  
6.  
7.  
8.  
Press the Esc key to return to the previous screen.  
Scroll to the I/O Device Configuration option, and press the Enter key.  
On the ProLiant DL140 G2 and ProLiant DL145 G2 servers, verify that Serial Port is set to BMC  
COM PORT.  
9.  
Follow the instructions in the "Network settings (on page 36)" section to set or obtain a valid IP  
address.  
10. Press the F10 key to save and exit.  
After completing the console redirection process, view the boot process remotely from a client computer  
through an established telnet session to the IP address of LO100. See your operating system  
documentation for instructions on establishing telnet sessions.  
When a telnet session is first established, an EMS> prompt appears. If the system is currently booting, the  
boot process is displayed. If you do not want to view boot, press the Esc+( keys. If the system is in the  
Operating System or off, the EMS> prompt appears, but disappears after pressing Enter.  
To redirect the console to the telnet session and view the boot process, press the Esc+Q keys in the telnet  
session during server boot. If you reset the server using the telnet connection and press the Esc+Q keys,  
the boot process might not appear immediately. The boot process appears after the server resets. To end  
the session, press the Esc+( keys.  
NOTE: If you encounter problems logging in to the remote console, be aware that some telnet  
programs might require you to enable their send line feed at end of lineoption. If  
the remote console does not respond to the Enter key, try setting this option in your telnet  
program.  
NOTE: You must follow the instructions in the "Network settings (on page 36)" section to  
configure the network access properly.  
Linux console redirection  
In the remote console and servers with the Linux operating system, you can enable a remote login on  
ttyS0 by making the following changes to the BIOS Setup Utility and boot documents.  
1.  
On the ProLiant DL140G2, ProLiant DL145G2, and ML150 G2 servers, verify or change the  
following:  
Console Redirection:  
Verify the following settings:  
o
Baud Rate: 9600  
Using LO100 44  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
o
o
o
o
Console Type: VT100+  
Flow Control: None  
Continue C.R. after POST: On  
Serial Port: BMC COM PORT (on the ProLiant DL140 G2 and ProLiant DL145 G2 servers only)  
NOTE: To customize the examples for your server, do the following:  
On DL140 G2 servers, replace ttyS0 with ttyS3  
On DL145 G2 servers, replace ttyS0 with ttyS2  
2.  
3.  
In the /boot/grub/menu.lst file, append the following to the kernel startup instruction:  
console=ttyS0 115200  
Comment out the line GRAPHICAL DISPLAY LINE  
# splashimage=(hd0,0)/grub/splash.xpm.gz  
Add an entry to allow serial console login in /etc/inittab. For example:  
S0:12345:respawn:/sbin/agetty -L 115200 ttyS0 vt102  
4.  
5.  
In /etc/securetty enable root access to ttyS0 by adding the ttyS0.  
In /etc/sysconfig/kudzu, set kudzu to not perform serial port probing during boot. For example:  
SAFE=yes  
6.  
After modifying and saving the following files, reboot the server. You can now log in to the  
operating system through remote console.  
After POST, in the remote console, the server prompts you with a login. Enter a valid login and use the  
server as you normally would. Use the ESC+Q keys to start remote console through the telnet and the  
ESC+( keys to exit the remote console in telnet.  
Microsoft Windows® EMS management  
Microsoft® Windows Server™ 2003 provides text-based console access. You can connect a laptop to the  
LO100 to perform basic management tasks on the target system. The Windows® EMS Console, if  
enabled, displays the processes that are running and enables administrators to halt processes. This  
capability is important in cases where video, device drivers, or other operating system features have  
prevented normal operation and normal corrective actions.  
To enable Windows® EMS management on the target system:  
1.  
2.  
Press the F10 key during POST to enter the BIOS Setup Utility.  
On ProLiant ML110 G3 servers:  
a. Press the down arrow () key to scroll down to the BIOS Serial Console Configuration option,  
and press Enter.  
b. Verify the following settings:  
BIOS Serial Console: Enabled  
Serial Over LAN (SOL): Enabled  
3.  
On ProLiant 140 G2, ProLiant DL145 G2, and ProLiant ML150 G2 servers, press the right arrow  
() key to scroll down to Advanced>Console Redirection menu.  
a. Press the down arrow () key to scroll down to EMS Console option, and press the Enter key to  
access the submenu.  
b. Verify the following settings:  
Using LO100 45  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Console Redirection: Enabled  
Baud Rate: 9600  
Terminal Type: VT100+  
Flow Control: None  
Redirection After BIOS POST: On  
4.  
Press the Esc key to return to the previous screen, or press the F10 key to save the changes and exit  
Setup.  
After enabling Windows® EMS management, you can view the Windows® EMS management console  
remotely from a client computer through an established telnet session to the IP address of the target server  
by pressing the Esc+Q keys. To end an EMS session press the Esc+( keys. See your operating system  
documentation for instructions on establishing telnet sessions.  
NOTE: If you encounter problems logging in to the remote console, be aware that some telnet  
programs might require you to enable their send line feed at end of lineoption. If  
the remote console does not respond to the Enter key, try setting this option in your telnet  
program.  
HP SIM support  
HP SIM discovers LO100 and enables you to identify and launch LO100. See your HP SIM user guide for  
more information on using HP SIM with LO100.  
Using LO100 46  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Acronyms and abbreviations  
BIOS  
Basic Input/Output System  
BMC  
baseboard management controller  
CLI  
Command Line Interface  
CLP  
command line protocol  
DHCP  
Dynamic Host Configuration Protocol  
DSA  
Digital Signature Algorithm  
EMS  
Emergency Management Services  
HP SIM  
HP Systems Insight Manager  
HTTP  
hypertext transfer protocol  
IP  
Internet Protocol  
IPMI  
Intelligent Platform Management Interface  
JVM  
Java Virtual Machine  
Acronyms and abbreviations 47  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
KCS  
Keyboard Controller Style  
KVM  
keyboard, video, and mouse  
LO100  
HP Lights-Out 100 Remote Management processors  
MAC  
medium access control  
NIC  
network interface controller  
OS  
operating system  
PEF  
Platform Event Filtering  
PEM  
Privacy Enhanced Mail  
PET  
Platform Event Trap  
POST  
Power-On Self Test  
RBSU  
ROM-Based Setup Utility  
SLES  
SUSE LINUX Enterprise Server  
SMASH  
System Management Architecture for Server Hardware  
SSH  
Secure Shell  
Acronyms and abbreviations 48  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SSL  
Secure Sockets Layer  
TCP/IP  
Transmission Control Protocol/Internet Protocol  
TFTP  
Trivial File Transfer Protocol  
URL  
uniform resource locator  
VNC  
virtual network computing  
Acronyms and abbreviations 49  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Index  
DHCP (Dynamic Host Configuration Protocol) 11,  
Dynamic Host Configuration Protocol (DHCP) 11,  
A
access options 28  
accessing software, browser 28  
administration 11  
B
E
BIOS (Basic Input/Output System) 16, 32  
BIOS console, text redirection 43  
BIOS upgrade 16  
browser-based setup 36  
Emergency Management Services (EMS) 45  
EMS Console 45  
Ethernet connections 14  
event log entries 34  
event log, BIOS setup access 35  
event log, browser access 34  
event log, CLP access 35  
C
CLP (Command Line Protocol) 5, 11, 14, 16, 21,  
CLP, general syntax 22, 23  
CLP, specific commands 27  
F
features, CLP 22  
features, IPMI 2.0 27  
firmware, updating 16  
H
Command Line Protocol (CLP) 5, 11, 14, 16, 21,  
configuration procedures 11  
configuration, network 11, 36  
configuring the LOM processor 11  
connectors, illustrated 8, 9  
console redirection 13  
hardware inventory 30  
HP Systems Insight Manager, support 46  
HTTP (hypertext transfer protocol) 11, 12, 15, 19  
hypertext transfer protocol (HTTP) 11, 12, 15, 19  
I
installation instructions 7, 9  
installation requirements 7  
console redirection, Linux 44  
installing management card 8, 9  
Intelligent Platform Management Interface (IPMI) 5,  
D
Index 50  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
IP (Internet Protocol) 11  
P
password, changing through a browser 42  
password, changing through the CLP 43  
IPMI (Intelligent Platform Management Interface) 5,  
Platform Event Filtering (PEF) 33, 41  
POST (Power-On Self Test) 9, 11  
post-installation procedures 9  
power control options 31  
power cycle server 30  
K
key, public 21  
kit contents 7  
powering on/off 30, 31, 32  
Power-On Self Test (POST) 9, 11  
preinstallation, guidelines 7  
priveleges, user 42  
public key 21  
L
LO100 settings 19  
LO100, logging in through browser 28  
LO100, remote management 19  
LO100c connectors 8, 9  
R
logging in, through a browser 28  
logging in, through the CLP 29  
RBSU (ROM-Based Setup Utility) 34  
remote console, using 43  
M
remote management card connectors 8, 9  
remote management processor, logging in through  
remote management, browser main menu 29  
remote server power, controlling 31, 32  
main menu functions 29  
medium access control (MAC) 41  
monitoring sensors 32  
ROMPaq utility 16  
N
network access 11  
network access, configuring 11  
network interface controller (NIC) 5, 7, 12, 13, 36,  
network settings 11, 36  
network settings, configuring through the BIOS  
network settings, configuring through the CLP 36  
NIC (network interface controller) 5, 7, 12, 13, 36,  
S
safety considerations 7  
Secure Sockets Layer (SSL) 21  
sensor data, BIOS access 32  
sensor data, browser access 32  
sensor data, viewing 32  
serial port, BIOS console configuration 13  
O
operational overview 5  
overview, CLP 22  
settings, power options 31  
side-band connection 14  
overview, server management 5  
SMASH (System Management Architecture for Server  
SSL, (Secure Sockets Layer) 21  
Index 51  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SSL, importing key and certificate 21  
SSL, using 19  
support, HP Systems Insight Manager 46  
system event log, access through the BIOS 35  
system event log, access through the CLP 35  
system event log, using 34  
System Management Architecture for Server  
T
TFTP (Trivial File Transfer Protocol) 16, 17, 21, 23,  
TFTP, configuration 17, 39  
Trivial File Transfer Protocol (TFTP) 16, 17, 21, 23,  
U
UID (unit identification) 5, 22  
unit identification (UID) 5, 22  
user and configuration settings 11, 42  
user guide updates 5  
V
virtual floppy, configuring from BIOS setup 40  
virtual power 30  
virtual storage interface (VSI) 13, 39, 40, 41  
VSI (virtual storage interface) 13, 39, 40, 41  
W
Windows® EMS Console, enabling 45  
Index 52  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Graco Marine Sanitation System 206405 User Manual
Graco Stroller 6907 User Manual
Groupe SEB USA T FAL Iron GV6500 User Manual
Hamilton Beach Coffee Grinder 80365C User Manual
Harbor Freight Tools Power Hammer 41983 User Manual
Hasbro Games 20176 User Manual
Hasbro Games The United States Air Mail Game User Manual
Heartland Refrigerator HCFDR20 User Manual
HP Hewlett Packard Network Card HP700196 User Manual
IFoundry Systems Switch IFSYS 5651 MSP430 User Manual