HP Hewlett Packard Server VA7110 User Manual

Chapter 4  
Peripherals and Accessories  
Subchapter 4.7—Disk Arrays  
4.7.1—HP StorageWorks Virtual Array 7000 Family: VA7100, VA7110 and  
VA7410  
Introduction  
The HP StorageWorks VA7000 Family arrays that support MPE/iX include the VA7100, VA7110 , and VA7410  
arrays. Where sections are specific to a particular array, they are called out. If a section is not specifically  
called out, it is common to all.  
For the latest configuration information, please refer to the SPOCK website (internal) or the Partnership  
Website (external):  
Spock Website:  
Partnership Website:  
Enterprise Virtual Array (EVA)  
For information on EVA support, please visit the following URLs:  
For Installation and Configuration and Release Notes  
In Spock, go to “Disk Array Connectivity” and select: HP StorageWorks EVA Technical Documentation  
Go there directly with the following URL:  
For Disk Array Connectivity  
HP StorageWorks EVA Product Index  
Go there directly with the following URL:  
Overview  
VA7100 Overview  
The HP StorageWorks Virtual Array 7100 is a disk storage system that holds from 4 to 15 disk drives. The array  
has scalable capacities from 72 GB to 270 GB (211 GB usable) with all 18-GB disk drives and from 144 GB to  
540 GB (428 GB usable) with all 36-GB disk drives and from 292 GB to 1.1 TB with 73-GB disk drives.  
Capacities and spindle speeds can also be mixed. The array requires a dual controller configuration to support  
MPE/iX. At least one controller must be attached to a management station running the HP StorageWorks  
Command View SDM software. Each controller has two DIMM slots available to hold NVRAM. The NVRAM is  
used for read/write caching and for storing array memory maps.  
The Virtual Array 7100 can operate in either RAID 1+0 mode or AutoRAID mode, which eliminates the  
requirement for the system administrator to understand and configure RAID levels. AutoRAID dynamically  
adapts to the system’s workload, optimizing performance and cost. Users will find configuration significantly  
easier than other array products, since RAID levels don’t need to be configured or managed. The VA7100  
supports one redundancy group, and all drives belong to that group. Using Virtual Storage Array (VSA)  
technology, when configured in AutoRAID mode the array controller automatically selects RAID 1+0 (disk  
striping and mirroring) or RAID 5DP (RAID 5 Double Parity) depending on the usage patterns of the data.  
HP e3000 Business Servers Configuration Guide – Effective 1/04  
4-91  
Information Subject to Change  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 4  
Peripherals and Accessories  
The VA7110 is designed to communicate with multiple hosts and multiple systems, otherwise known as  
heterogeneous support. Any combination of the supported operating systems—HP-UX, Windows NT, Solaris,  
AiX, NetWare, Windows 2000, MPE/iX, and Linux can be used. Two different protocols, or host port behaviors,  
are used by the array to communicate with the operating systems: one protocol for Windows/Linux/other and  
another for HP-UX. The Windows/Linux host port behaviors must be configured in the array for  
communication to take place with any or all four supported operating systems on a controller. When changing  
the port protocol to Windows/Linux it does support concurrent operation with Windows/Linux and HP-UX.  
The VA7110 provides simultaneous access by all of the supported operating systems on a LUN-by-LUN basis.  
Each LUN operates appropriately given the description of the operating system requirements.  
The VA7110 can be configured to utilize an active hot spare feature. An active hot spare is a portion of the disk  
array capacity reserved to perform a rebuild. This feature requires the use of one or two additional disk units  
in the array. An active hot spare ensures that the disk array can maintain data redundancy if one or two disks  
fails. Until it is needed, the disk array uses the active hot spare storage space as RAID 1+0 capacity, which  
improves array performance. The active hot spare storage capacity does not sit idle; it is used to increase the  
disk array performance until the storage is needed.  
Each enclosure will accommodate up to 15 low-profile 3.5-inch hard disk drives loaded from the front. The  
array requires three EIA units (3U) in height (per enclosure), which allows ten units to be placed in a standard  
1.6-meter rack. The rear of the EIA rack mountable chassis also includes two 1-GB fibre channel controllers,  
dual power supplies and dual fan modules. The redundant power supply and fan components are combined  
into a single module. All modules are hot swappable.  
The array can be connected to one or more hosts, hubs, or switches via an optical fibre channel (FC) interface  
with 1 or 2 gigabit per second transfer rates (the default setting is 1 gigabit). It can be ordered in  
factory-racked, field-rackable, or desk-side configurations. Factory-racked products are pre-configured in the  
HP Rack/System E racks. Field-rackable products can be racked in HP racks or in Compaq 9000 racks.  
The VA7110 is supported by HP’s Instant Support Enterprise Edition (ISEE). HP’s online diagnostic and  
resolution capability securely delivers remote reactive services that quickly resolve problems, proactive  
service that anticipate and prevent downtime due to computing issues, and value-added services to help  
monitor, manage and maintain global IT networks. A minimum level hardware support upgrade of same day is  
required. It is included with the VA for the first year.  
The revision numbering for firmware for the VA7110 has changed. The revision numbering now consists of a  
string of 4 ASCII characters (the HP designation has gone away). For example, a revision code of “X123”  
represents the following:  
“X” is a single capital letter (A – Z) designating the platform  
“1” is a single number or capital letter (0-9, A-Z) designating a major FW revision  
“2” is a single number or capital letter (0-9, A-Z) designating a minor FW revision  
“3” is a single number or capital letter (0-9, A-Z) designating a sub-minor FW revision  
VA7410 Overview  
The HP StorageWorks Virtual Array 7410 is a Fibre Channel (FC) disk storage system that supports from ten to  
105 disk drives. The VA7410 has two FC ports on each controller. The VA7410 is comprised of two types of  
enclosures, each three EIA units high: the virtual array controller enclosure (A6183A/AZ) and the disk system  
enclosure (A6214A/AZ) also referred to as the disk enclosure or the JBOD (Just a Bunch Of Disks) enclosure.  
In addition, pre-defined SKUs are available to facilitate integrated arrays. The array consists of one controller  
enclosure and one to six disk enclosures, with scalable capacities from 181 GB to 1.90 TB (using 18-GB 15K  
rpm disk drives), 364 GB to 3.82 TB (using 36-GB 10K rpm disk drives), 720 GB to 7.67 TB (using 73-GB 10K  
rpm disk drives), or 1.46 TB to 15.33 TB (using 146-GB 10K rpm disk drives). Capacities and spindle speeds can  
also be mixed throughout the array.  
HP e3000 Business Servers Configuration Guide – Effective 1/04  
4-93  
Information Subject to Change  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 4  
Peripherals and Accessories  
Both enclosures include dual power supplies with built-in dual blowers, and accommodate up to 15 low-profile  
3.5-inch native fibre channel (FC) disk drives in the front. The controller enclosure also includes dual  
redundant 1 or 2-Gbps FC capable array controller cards and the disk enclosure also includes dual redundant  
1- or 2-Gbps link controller cards for back-end connections to the controllers. All field replaceable units are  
hot swappable. The array controller cards, however, must be replaced offline if the OS does not support  
controller failover.  
The VA7410 can operate in either RAID 1+0 mode or AutoRAID mode. These data protection levels are user  
selectable at the time of initial array installation. Using Virtual Storage Array (VSA) technology, when  
configured in AutoRAID mode the array controller automatically selects RAID 1+0 (disk striping and  
mirroring) or RAID 5DP (RAID 5 Double Parity) depending on the usage patterns of the data. This protection  
scheme eliminates the requirement for the system administrator to understand and configure RAID levels.  
RAID 5DP provides superior data redundancy by protecting against the simultaneous failure of two member  
disks by using independent error correction schemes. Users will find configuration significantly easier than  
other array products, since RAID levels don’t need to be configured or managed. The VA7410 supports two  
redundancy groups, which provides for physical data path separation of the two groups of LUNS.  
The VA7410 is architected to communicate with multiple hosts and operating systems, otherwise known as a  
simultaneous heterogeneous environment. For details on supported operating systems, please refer to the  
Spock Website and Partnership Website:  
Spock website:  
Partnership website:  
One host port behavior is initially set in controller firmware, and then heterogeneous support for all other  
operating systems is enabled through software in a host port behavior table. The controller default host port  
behavior is set for HP-UX. The VA7xxx products are managed by the HP Command View SDM host-resident  
software. A one-host license to use for HP StorageWorks Command View SDM is included with each VA7410.  
Currently HP StorageWorks Command View SDM runs native on HP-UX, Windows NT, Windows 2000 and Red  
Hat Linux 6.2, 7.1. Installations on any of the other supported operating systems will require a dedicated  
management station running one of the aforementioned operating systems to be in the data path of the VA7410  
(i.e. in the switched fabric).  
The VA7410 can be configured to use an active hot spare feature. An active hot spare is a portion of the array  
capacity reserved to perform a rebuild. This feature requires the use of additional disk drives in the array.  
Users can select from 0, 1, or 2 active hot spares. An active hot spare ensures that the array can maintain data  
redundancy if one or two disks fail. Until it is needed, the array uses the active hot spare storage space as RAID  
1+0 capacity, which improves array performance. The active hot spare storage capacity does not sit idle; it is  
used to increase the array performance until the storage it is needed.  
The VA7410 can be connected to one or more hosts, hubs, or switches via an optical fibre channel (FC)  
interface with OS-dependant, 1- or 2-Gbps transfer rates. The default factory setting is 1-Gbps. It can be  
ordered in factory-racked and field-rackable configurations. Factory-racked products are pre-configured in the  
HP Rack/System E racks. Field-rackable products can be racked in HP racks or in Compaq 9000 racks.  
The VA7410 is supported by HP’s Instant Support Enterprise Edition (ISEE). HP’s online diagnostic and  
resolution capability securely delivers remote reactive services that quickly resolve problems, proactive  
service that anticipate and prevent downtime due to computing issues, and value-added services to help  
monitor, manage and maintain global IT networks. A minimum level hardware support upgrade of same day is  
required.  
4-94  
HP e3000 Business Servers Configuration Guide – Effective 1/04  
Information Subject to Change  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 4  
Peripherals and Accessories  
New Firmware Revision Code Designation for VA7410  
Note: The release firmware for the VA7410 is “A100”.  
The revision numbering for firmware for the VA7410 has changed. The revision numbering now consists of a  
string of 4 ASCII characters (the HP designation has gone away). For example, a revision code of “X123”  
represents the following:  
“X” is a single capital letter (A – Z) designating the platform  
“1” is a single number or capital letter (0-9, A-Z) designating a major FW revision  
“2” is a single number or capital letter (0-9, A-Z) designating a minor FW revision  
“3” is a single number or capital letter (0-9, A-Z) designating a sub-minor FW revision  
Important VA7410/DS2405 Notes:  
On the VA7410 only the DS2405 is supported. For the VA7410, HP StorageWorks Command View SDM  
software version 1.05 or later is required.  
Disk drive firmware may need to be upgraded. For more information, please check the Service Note server  
at the following site and do a search on the VA family via product numbers to see all available and relevant  
Additionally, on the DS2405, the LCC FC loop speed must be set to 2-Gbps (this is the factory default). If  
needed, refer to the DS2405 User Guide on setting LCC speed.  
The DS2405 is not supported connected directly to a switch.  
If you are upgrading to a VA7410 from an array with DS2400 JBODs, the DS2400 JBODs must also be  
upgraded to DS2405 JBODs.  
Product Features  
Integrated VA arrays contain two (2) controllers. The array controllers contain the intelligence and  
functionality required to manage the operation of the entire array. The array functions include:  
Implementing HP Virtual Storage Technology to ensure optimum performance and cost-efficient data  
storage  
Managing all communication between the host and the disk drives via single or dual controller Fibre  
Channel arbitrated loops  
Maintaining data integrity by automatically correcting any data errors that occur  
Rebuilding the array in the event of a disk failure  
Monitoring the operation of all hardware components, including the controller itself  
Alerting the host in the event of a component failure  
The use of two controllers protects the array against a single controller failure. Both controllers may be active,  
allowing a possible increase in performance, while providing data redundancy.  
Each configured array controller includes the following components:  
One (1) or two (2) Dual Inline Memory Modules (DIMMs), purchased separately if an additional Virtual  
Array Controller is added  
One (1) Battery  
One (1) Early Warning Switch  
HP e3000 Business Servers Configuration Guide – Effective 1/04  
4-95  
Information Subject to Change  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 4  
Peripherals and Accessories  
Performance, Throughput and Capacity  
Item  
Value  
100 MB/s FC  
200 MB/s FC  
200 MB/s FC  
200 MB/s FC  
100 MB/s FC  
Throughput Host Interface VA7100  
Throughput Host Interface VA7110  
Throughput Host Interface VA7400  
Throughput Host Interface VA7410  
Drive Interface  
Disk System Capacity VA7100  
Disk System Capacity VA7110  
Disk System Capacity VA7400  
Disk System Capacity VA7410  
Storage Controller  
1095 GB raw capacity  
6.5 TB raw capacity  
7.6 TB GB raw capacity  
15.3 TB GB raw capacity  
High-performance Virtual Array Controller  
18 GB, 36.4 GB 73 GB and 146 GB (Note the 146 GB drive is for the VA7110 only  
Disk Drive Capacity  
Rotational Velocity  
10K RPM and 15K RPM  
Disk Drive Transfer Rate  
Disk Drive Average Seek Time  
Disk Drive Average Latency  
10K = 26 MB/s (or better); 15K = 38 MB/s (or better)  
10K = 4.7 ms (or better) Read, 5.2 ms (or better) Write; 15K = 3.6 ms (or better) Read, 4.2 ms (or better) Write  
10K = 2.99 ms, 15K = 2.00 ms  
VA7110 Disk Enclosure Specifications (DS2405)  
Physical Specifications  
Height  
5 in  
128 mm  
Width  
17.6 in  
448 mm  
Depth  
20 in  
508 mm  
Net Weight Max  
84.5 lbs  
38.3 kg  
Shipping Weight Max  
101.5 lbs  
46 kg  
Electrical Specifications  
Parameter  
Value  
Voltage (Auto-Ranging)  
Frequency  
100-127 VAC; 200-240 VAC  
50/60 Hz  
Current (Maximum; 2 power inputs)  
Inrush Current (Peak)  
8.2 A @ 100 VAC, 3.4 A @ 200 VAC  
3.92 A @ 269 VAC  
Power Consumption  
Heat Dissipation  
473 W @ 120 VAC, 457 W @ 240 VAC  
1443 BTU/hr  
VA Rating (Maximum Configuration)  
473 VA @ 120 VAC, 457 VA @ 240 VAC  
Environmental Specifications  
Parameter  
Temperature  
Temperature Gradient  
Relative Humidity (Non-Condensing) 15% to 80% @ 28° C (dry bulb)  
Operating Range  
5° to 35° C (41° to 95° F)  
20° C (36° F) per hour  
Recommended Range  
20° to 25.5° C (68° to 78° F)  
20° C (36° F) per hour  
30% to 50% @ 28° C (dry bulb)  
N/A  
Non-Operating  
–40° to 70° C (-40° to 158° F)  
20° C (36° F) per hour  
5% to 95% @ 65° C (149° F)  
20 g, 30 ms trapezoidal  
Shock  
4 g, 11 ms (20 low-impulse pulses)  
(non-transport) 1-inch edge drops per  
side (transport)  
Vibration  
0.21 g rms, 5- to 500-Hz random  
N/A  
2.09 g rms, 5- to 500-Hz random  
0.5 g peak, 5- to 500-Hz swept sine  
0 ft to 15,000 ft (0 to 4,572 m)  
N/A  
Altitude  
Acoustic (ISO 9296)  
0 ft to 10,000 ft (0 to 3,048 m)  
8.0 bels  
0 ft to 10,000 ft (0 to 3,048 m)  
8.0 bels  
Regulatory Compliance  
Parameter  
Specification  
Radiated and Conducted Emissions  
Immunity  
FCC Class A, EN 55022: 1998, CISPR-22: 1997 Level A, and GB9254: 1998  
EN 55024: 1998/CISPR-24: 1997  
Harmonic Current  
Voltage Fluctuations and Flicker  
Product Safety  
IEC 61000-3-2: 1998/EN 61000-3-2: 1995 + A14  
IEC 61000-3-3: 1994/EN 61000-3-3: 1995  
EN 60950: 1991, Second Edition + A1, A2, A3, and A4  
CAN/CSA - C22.2 No. 60950-00, Third Edition  
UL 1950: Third Edition IEC 60825-1: 1993 + A1/EN 60825-1: 1994 + A11  
Class 1 (Laser/LED)  
GB4943: 1995  
4-96  
HP e3000 Business Servers Configuration Guide – Effective 1/04  
Information Subject to Change  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 4  
Peripherals and Accessories  
Warranty  
Included with every VA7000 Family Array:  
Warranty: 2-year, 8×5, same-day, 4-hour on-site response for hardware with a 2-year 8×5 phone-in assistance,  
2-hour response for HP StorageWorks Command View SDM phone-in assistance (PIA)  
Required with purchase:  
VA Family Hardware and Software: Installation service—H4726A  
Pre-installation review  
Hardware installation  
Software enablement  
LUN Design and Implementation  
Customer documentation and orientation  
VA Family Software: 8×5 Phone-in-Assistance (H4403A, Support Pack)  
Instant Support Enterprise Edition Support (ISEE)  
What is Instant Support Commercial  
HP Instant Support is a unique combination of web-based self-service diagnostics and knowledge base access  
and is offered as a free value-added service for HP desktop computers, mobile computers, technical  
workstations, and PC servers.  
ISC Value Proposition  
HP Instant Support automates and speeds the resolution of computing problems, freeing customers from  
time-consuming diagnostic chores and returning them to more productive business-critical tasks.  
Links of Interest  
Instant Support Commercial (European server)—  
Instant Support (desktop/printers)—WW Marketing Page http://www.hp.com/go/instantsupport  
HPCS eDelivery EMEA—http://hpsedelivery.europe.hp.com/  
Specifications  
VA7100 Specifications  
Racked Product Physical Specifications  
Height  
5.0 in  
128 mm  
Width  
17.6 in  
448 mm  
Depth  
26 in  
660 mm  
Net Weight Minimum  
75 lbs  
34 kg  
Deskside Product Physical Specifications  
Height  
19 in  
483 mm  
Width  
Depth  
26 in  
660 mm  
Net Weight Minimum  
105 lbs  
47.6 kg  
16.5 in (box (6.5) + base (10)  
419 mm  
HP e3000 Business Servers Configuration Guide – Effective 1/04  
4-97  
Information Subject to Change  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 4  
Peripherals and Accessories  
Deskside and Racked Product Electrical Specifications (VA7100 only)  
Parameter  
Value  
Voltage  
100-127 and 200-240 VAC (auto-ranging)  
Frequency  
50/60 Hz  
Current (Maximum)  
Inrush Current (Peak)  
Power Consumption  
Heat Dissipation  
VA Rating (Maximum Configuration)  
7.2 Amps RMS (2 power inputs)  
36 Amps  
670 Watts  
196 BTU  
720 VA  
Deskside/Racked Product Environmental Specifications  
Parameter  
Temperature  
Operating Range  
5° to 35° C  
20° C (36° F) per hour  
Recommended Range  
20º C to 25.5º C (68º F to 78º F)  
20° C (36° F) per hour  
30% to 50% @ 28° C (wet bulb)  
N/A  
Non-Operating  
–40° to 70° C  
20° C per hour  
10% to 90% @ 28° C (wet bulb)  
4 g, 11 ms half sine  
2.09 g rms, 5- to 500-Hz random  
0.5-g peak, 5- to 500-Hz swept sine  
0 ft to 15,000 ft  
Temperature Gradient  
Relative Humidity (non-condensing) 10% to 80% @ 28° C (wet bulb)  
Shock  
Vibration  
4 g, 11 ms half sine  
0.21g rms, 5- to 500-Hz random  
N/A  
Altitude  
Acoustic (ISO 9296)  
0 ft to 10,000 ft  
8.0 bels  
0 ft to 10,000 ft  
8.0 bels  
N/A  
Deskside/Racked Product Regulatory Compliance  
Parameter  
Specification  
Radiated and Conducted Emissions  
Immunity  
FCC Class A, EN 55022: 1998, CISPR-22: 1997 Level A, and GB9254: 1998  
EN 55024: 1998/CISPR-24: 1997  
Harmonic Current  
Voltage Fluctuations and Flicker  
Product Safety  
IEC 61000-3-2: 1998/EN 61000-3-2: 1995 + A14  
IEC 61000-3-3: 1994/EN 61000-3-3: 1995  
EN 60950: 1991, Second Edition + A1, A2, A3, and A4  
CAN/CSA - C22.2 No. 60950-00, Third Edition  
UL 1950: Third Edition IEC 60825-1: 1993 + A1/EN 60825-1: 1994 + A11  
Class 1 (Laser/LED)  
GB4943: 1995  
VA7110 and VA7410 Controller Enclosure Specifications  
Physical Specifications  
Height  
5 in  
128 mm  
Width  
17.6 in  
448 mm  
Depth  
26 in  
660 mm  
Net Weight Max  
34 lbs  
41.8 kg  
Shipping Weight Max  
130.1 lbs  
59.0 kg  
Electrical Specifications  
Parameter  
Value  
Voltage (Auto-Ranging)  
Frequency  
100-127 VAC, 200-240 VAC  
50/60 Hz  
Current (Maximum; 2 power inputs)  
Inrush Current (Peak)  
8.2 A @ 100 VAC, 3.6 A @ 200 VAC  
36 A  
Power Consumption  
670 W  
Heat Dissipation  
VA Rating (Maximum Configuration)  
196 BTU/hr  
720 VA  
4-98  
HP e3000 Business Servers Configuration Guide – Effective 1/04  
Information Subject to Change  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 4  
Peripherals and Accessories  
Environmental Specifications  
Parameter  
Temperature  
Temperature Gradient 20° C (36° F) per hour  
Relative Humidity  
Shock  
Operating Range  
5° to 35° C (41° to 95° F)  
Recommended Range  
20º to 25.5º C (68º to 78º F)  
20° C (36° F) per hour  
30% to 50% @ 28° C (dry bulb)  
N/A  
Non-Operating  
–40° to 70° C (-40° to 158° F)  
20° C (36° F) per hour  
10% to 90% @ 28° C (dry bulb)  
4 g, 11 ms half sine  
15% to 80% @ 28° C (dry bulb)  
4 g, 11 ms half sine  
Vibration  
0.21 g rms, 5- to 500-Hz random  
N/A  
2.09 g rms, 5- to 500-Hz random  
0.5 g peak, 5- to 500-Hz swept sine  
0 ft to 15,000 ft (0 to 4,572 m)  
N/A  
Altitude  
Acoustic (ISO 9296)  
0 ft to 10,000 ft (0 to 3,048 m)  
8.0 bels  
0 ft to 10,000 ft (0 to 3,048 m)  
8.0 bels  
Regulatory Compliance  
Parameter  
Specification  
Radiated and Conducted Emissions  
Immunity  
FCC Class A, EN 55022: 1998, CISPR-22: 1997 Level A, and GB9254: 1998  
EN 55024: 1998/CISPR-24: 1997  
Harmonic Current  
Voltage Fluctuations and Flicker  
Product Safety  
IEC 61000-3-2: 1998/EN 61000-3-2: 1995 + A14  
IEC 61000-3-3: 1994/EN 61000-3-3: 1995  
EN 60950: 1991, Second Edition + A1, A2, A3, and A4  
CAN/CSA - C22.2 No. 60950-00, Third Edition  
UL 1950: Third Edition IEC 60825-1: 1993 + A1/EN 60825-1: 1994 + A11  
Class 1 (Laser/LED)  
GB4943: 1995  
DS2405 Disk Enclosure Specifications  
Physical Specifications  
Height  
5 in  
128 mm  
Width  
17.6 in  
448 mm  
Depth  
20 in  
508 mm  
Net Weight Max  
84.5 lbs  
38.3 kg  
Shipping Weight Max  
101.5 lbs  
46 kg  
Electrical Specifications  
Parameter  
Value  
Voltage (Auto-Ranging)  
Frequency  
100-127 VAC; 200-240 VAC  
50/60 Hz  
Current (Maximum; 2 power inputs)  
Inrush Current (Peak)  
8.2 A @ 100 VAC, 3.4 A @ 200 VAC  
3.92 A @ 269 VAC  
Power Consumption  
Heat Dissipation  
473 W @ 120 VAC, 457 W @ 240 VAC  
1443 BTU/hr  
VA Rating (Maximum Configuration)  
473 VA @ 120 VAC, 457 VA @ 240 VAC  
Environmental Specifications  
Parameter  
Temperature  
Temperature Gradient  
Relative Humidity (Non-Condensing) 15% to 80% @ 28° C (dry bulb)  
Operating Range  
5° to 35° C (41° to 95° F)  
20° C (36° F) per hour  
Recommended Range  
20° to 25.5° C (68° to 78° F)  
20° C (36° F) per hour  
30% to 50% @ 28° C (dry bulb)  
N/A  
Non-Operating  
–40° to 70° C (-40° to 158° F)  
20° C (36° F) per hour  
5% to 95% @ 65° C (149° F)  
20 g, 30 ms trapezoidal  
Shock  
4 g, 11 ms (20 low-impulse pulses)  
(non-transport) 1-inch edge drops per  
side (transport)  
Vibration  
0.21 g rms, 5- to 500-Hz random  
N/A  
2.09 g rms, 5- to 500-Hz random  
0.5 g peak, 5- to 500-Hz swept sine  
0 ft to 15,000 ft (0 to 4,572 m)  
N/A  
Altitude  
Acoustic (ISO 9296)  
0 ft to 10,000 ft (0 to 3,048 m)  
8.0 bels  
0 ft to 10,000 ft (0 to 3,048 m)  
8.0 bels  
HP e3000 Business Servers Configuration Guide – Effective 1/04  
4-99  
Information Subject to Change  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 4  
Peripherals and Accessories  
Regulatory Compliance  
Parameter  
Specification  
Radiated and Conducted Emissions  
Immunity  
FCC Class A, EN 55022: 1998, CISPR-22: 1997 Level A, and GB9254: 1998  
EN 55024: 1998/CISPR-24: 1997  
Harmonic Current  
Voltage Fluctuations and Flicker  
Product Safety  
IEC 61000-3-2: 1998/EN 61000-3-2: 1995 + A14  
IEC 61000-3-3: 1994/EN 61000-3-3: 1995  
EN 60950: 1991, Second Edition + A1, A2, A3, and A4  
CAN/CSA - C22.2 No. 60950-00, Third Edition  
UL 1950: Third Edition IEC 60825-1: 1993 + A1/EN 60825-1: 1994 + A11  
Class 1 (Laser/LED)  
GB4943: 1995  
Figure 4.7.1.1 HP StorageWorks Virtual Array 7000 Family – Front View  
Figure 4.7.1.2 HP StorageWorks Virtual Array 7100  
Figure 4.7.1.3 HP StorageWorks Virtual Array 7100—Deskside Configuration  
4-100  
HP e3000 Business Servers Configuration Guide – Effective 1/04  
Information Subject to Change  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 4  
Peripherals and Accessories  
Figure 4.7.1.4 VA7100—Rear View  
Array  
Controller  
LEDs  
Fibre  
Channel  
Port  
RS-232  
Serial  
Port  
Array  
Controller  
AC Power  
Connection  
Power  
Supply  
LEDs  
Power  
Supply  
Figure 4.7.1.5 StorageWorks VA7110—Front and Rear View  
1
4
3
2
6
5
8
10  
2
7
9
11  
12  
disk 2  
host 2  
disk  
host  
14  
13  
15  
16  
Figure 4.7.1.6 VA7410—Rear View  
Array  
Controller RS-232  
Array  
Controller  
Card 2  
Array Disk Ports Host Ports  
Controller  
Card 1  
FC  
FC  
2
LEDs  
Connector  
1
2
1
AC Power  
Connection  
Power  
Module 1  
Power  
Module LEDs  
Power  
Module 2  
HP e3000 Business Servers Configuration Guide – Effective 1/04  
4-101  
Information Subject to Change  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 4  
Peripherals and Accessories  
Figure 4.7.1.7 StorageWorks DS2405—Rear View  
Array  
Controller RS-232  
LEDs  
Array  
Controller  
Card 2  
Array Disk Ports Host Ports  
Controller  
Card 1  
FC  
FC  
2
Connector  
1
2
1
AC Power  
Connection  
Power  
Module 1  
Power  
Module LEDs  
Power  
Module 2  
Hardware Ordering Information  
VA7100 Hardware Ordering Information  
The following codes define the suffixes on product numbers: A = Field Racked, AE = diskless enclosure (field  
disk integration), AZ = Factory Racked.  
Order drives separately from the Enterprise Module section using the 0D1 option for integration. “AE”  
products are shipped as diskless enclosure only no integration (disks are ordered separately and field  
installed).  
Product Number Option Number Description  
VA7100 Field RK SKU  
A6261A  
A6262A  
A6263A  
A6183A  
Predefined SKU - VA7100 with Dual Controller, 2 GBICs, 256-MB Cache  
Predefined SKU - VA7100 with Dual Controller, 2 GBICs, 512-MB Cache (1×512MB DIMM)  
Predefined SKU - VA7100 with Dual Controller, 2 GBICs, 1024-MB Cache (2×512MB DIMM)  
Field upgrade product. Select Virtual Array Controller (one or two) and cache and disk options separately (factory  
installed). Includes filler for controllers and disks.  
A6188A  
A6185A  
0D1  
0D1  
Virtual Array Controller no memory installed  
256-MB Cache for Virtual Array Controller, 1×256MB DIMM, StorageWorks VAP requires equal cache for both  
Controllers (if 2nd installed). Order 1 per installed VAP  
A6186A  
A6187A  
0D1  
0D1  
512-MB Cache for Virtual Array Controller, 1×512MB DIMM, StorageWorks VAP requires equal cache for both  
Controllers (if 2nd installed). Order 1 per installed VAP  
2×512MB Cache for Virtual Array Controller, 2×512MB DIMM, StorageWorks VAP requires equal cache for both  
Controllers (if 2nd installed). Order 1 per installed VAP  
A6192A  
A6193A  
A6194A  
A7288A  
A6203A  
A3583A  
A3531A  
A3735A  
A3736A  
C7529A  
C7530A  
C7534A  
C7540A  
0D1  
0D1  
0D1  
0D1  
0D1  
0D1  
0D1  
0D1  
0D1  
0D1  
0D1  
0D1  
0D1  
36-GB 10K RPM FC HDD Module  
36-GB 15K RPM FC HDD Module  
73-GB 10K RPM FC HDD Module  
73-GB 15K RPM FC HDD Module  
Optical Gigabit Interface Circuit (GBIC)  
2-meter FC fiber optic cable M/M multimode SC-SC  
16-meter FC fiber optic cable M/M multimode SC-SC  
50-meter FC fiber optic cable M/M multimode SC-SC  
100-meter FC fiber optic cable M/M multimode SC-SC  
2-meter FC fiber optic cable M/M duplex LC-SC  
16-meter FC fiber optic cable M/M duplex LC-SC  
FC fiber optic coupler F/F SC-SC  
FC adapter kit (includes C7529A and C7534A)  
4-102  
HP e3000 Business Servers Configuration Guide – Effective 1/04  
Information Subject to Change  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 4  
Peripherals and Accessories  
Product Number Option Number Description  
VA7100 Factory Rack  
A6261AZ  
A6262AZ  
A6263AZ  
A6183AZ  
Predefined SKU - VA7100 with Dual Controller, 2 GBICs, 256-MB Cache  
Predefined SKU - VA7100 with Dual Controller, 2 GBICs, 512-MB Cache (1×512MB DIMM)  
Predefined SKU - VA7100 with Dual Controller, 2 GBICs, 1024-MB Cache (2×512MB DIMM)  
Field upgrade product. Select Virtual Array Controller (one or two) and cache and disk options separately (factory  
installed). Field Installed. Includes enclosure assembly, user manual, and 2 power supplies, filler panels for controllers  
and disks.  
A6188A  
A6185A  
0D1  
0D1  
Virtual Array Controller no memory installed  
256-MB Cache for Virtual Array Controller, 1×256MB DIMM, StorageWorks VAP requires equal cache for both  
Controllers (if 2nd installed). Order 1 per installed VAP  
512-MB Cache for Virtual Array Controller, 1×512MB DIMM, StorageWorks VAP requires equal cache for both  
Controllers (if 2nd installed). Order 1 per installed VAP  
2×512MB Cache for Virtual Array Controller, 2×512MB DIMM, StorageWorks VAP requires equal cache for both  
Controllers (if 2nd installed). Order 1 per installed VAP  
36-GB 10K RPM FC HDD Module  
36-GB 15K RPM FC HDD Module  
73-GB 10K RPM FC HDD Module  
73-GB 15K RPM FC HDD Module  
Optical Gigabit Interface Circuit (GBIC)  
2-meter FC fiber optic cable M/M multimode SC-SC  
16-meter FC fiber optic cable M/M multimode SC-SC  
50-meter FC fiber optic cable M/M multimode SC-SC  
100-meter FC fiber optic cable M/M multimode SC-SC  
2-meter FC fiber optic cable M/M duplex LC-SC  
16-meter FC fiber optic cable M/M duplex LC-SC  
FC fiber optic coupler F/F SC-SC  
FC adapter kit (includes C7529A and C7534A)  
A6186A  
A6187A  
0D1  
0D1  
A6192A  
A6193A  
A6194A  
A7288A  
A6203A  
A3583A  
A3531A  
A3735A  
A3736A  
C7529A  
C7530A  
C7534A  
C7540A  
VA7100 Modules  
A6183AE  
0D1  
0D1  
0D1  
0D1  
0D1  
0D1  
0D1  
0D1  
0D1  
0D1  
0D1  
0D1  
0D1  
Field upgrade product. Select Virtual Array Controller (one or two) and cache product separately (factory installed).  
Field Installed. Includes enclosure assembly, user manual, and 2 power supplies. This product is shipped without disks  
or controllers/cache and includes filler for controllers and disks.  
Predefined SKU - VA7100 with Dual Controller, 2 GBICs, 256-MB Cache  
Predefined SKU - VA7100 with Dual Controller, 2 GBICs, 512-MB Cache (1×512-MB DIMM)  
Predefined SKU - VA7100 with Dual Controller, 2 GBICs, 1024-MB Cache (2×512-MB DIMM)  
Virtual Array Controller no memory installed  
A6261AE  
A6262AE  
A6263AE  
A6188A  
A6185A  
256-MB Cache for Virtual Array Controller, 1×256MB DIMM, StorageWorks VAP requires equal cache for both  
Controllers (if 2nd installed). Order 1 per installed VAP  
A6186A  
A6187A  
512-MB Cache for Virtual Array Controller, 1×512MB DIMM, StorageWorks VAP requires equal cache for both  
Controllers (if 2nd installed). Order 1 per installed VAP  
2×512MB Cache for Virtual Array Controller, 2×512MB DIMM, StorageWorks VAP requires equal cache for both  
Controllers (if 2nd installed). Order 1 per installed VAP  
A6192A  
A6193A  
A6194A  
A7288A  
A6196A  
A6203A  
A3583A  
A3531A  
A3735A  
A3736A  
C7529A  
C7530A  
C7534A  
C7540A  
36-GB 10K RPM FC HDD Module  
36-GB 15K RPM FC HDD Module  
73-GB 10K RPM FC HDD Module  
73-GB 15K RPM FC HDD Module  
Deskside cabinet for HP StorageWorks VA7100  
Optical Gigabit Interface Circuit (GBIC)  
2-meter FC fiber optic cable M/M multimode SC-SC  
16-meter FC fiber optic cable M/M multimode SC-SC  
50-meter FC fiber optic cable M/M multimode SC-SC  
100-meter FC fiber optic cable M/M multimode SC-SC  
2-meter FC fiber optic cable M/M duplex LC-SC  
16-meter FC fiber optic cable M/M duplex LC-SC  
FC fiber optic coupler F/F SC-SC  
FC adapter kit (includes C7529A and C7534A)  
0D1  
HP e3000 Business Servers Configuration Guide – Effective 1/04  
4-103  
Information Subject to Change  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 4  
Peripherals and Accessories  
VA7100 Rail Kits  
The following rail kits are needed to mount the VA7100 into the specific racks as listed.  
Part Number  
A6209A  
A6496A  
Description  
System/E Rail Kit (RoseBowl 2)  
NTRittal Rack rail kit  
A6244A  
HP Original rack rackmount hardware kit  
VA7110 Hardware Ordering Information  
The following codes define the suffixes on product numbers: A = Field Racked, AE = diskless enclosure (field  
disk integration), AZ = Factory Racked.  
Order drives separately from the Enterprise Module section using the 0D1 option for integration. “AE”  
products are shipped as diskless enclosure only no integration (disks are ordered separately and field  
installed).  
Product Number Option Number Description  
VA7110 Field RK SKU  
A7294A  
A7296A  
A7293A  
Predefined SKU - VA7110 with Dual Controller, 2 GBICs, 1024-MB Cache (2×512MB DIMM)  
Predefined SKU - VA7110 with Dual Controller, 2 GBICs, 2048-MB Cache (2×1024MB DIMM)  
Field upgrade product. Select Virtual Array Controller (two) and cache (minimum 1024 MB) and disk options separately  
(factory installed). Includes filler for controllers and disks. (Note that single controller configurations are not  
supported!)  
0D1  
A6183AE  
A7293A  
A6186A  
Empty Enclosure  
0D1  
0D1  
Virtual Array Controller no memory installed (Note that single controller configurations are not supported!)  
1×512MB Cache for Virtual Array Controller, 1×512MB DIMM, StorageWorks VAP requires equal cache for both  
Controllers (if two are installed). Order 1 per installed VAP  
1×1024MB Cache for Virtual Array Controller, 1×1024MB DIMM, StorageWorks VAP requires equal cache for both  
Controllers (if two are installed). Order 1 per installed VAP  
36-GB 10K RPM FC HDD Module  
36-GB 15K RPM FC HDD Module  
73-GB 10K RPM FC HDD Module  
73-GB 15K RPM FC HDD Module  
146-GB 10K RPM FC HDD Module  
Fiber Optic Cable 2-meter LC 50/125 M/M  
Fiber Optic Cable 16-meter LC Duplex 50/125 M/M  
Fiber Optic Cable 50-meter LC Duplex 50/125 M/M  
Fiber Optic Cable 200-meter LC Duplex 50/125 M/M  
2-meter FC fiber optic cable M/M duplex LC-SC  
16-meter FC fiber optic cable M/M duplex LC-SC  
FC fiber optic coupler F/F SC-SC  
FC adapter kit (includes C7529A and C7534A)  
A6187B  
0D1  
A6192A  
A6193A  
A6194A  
A7288A  
A7289A  
C7524A  
C7525A  
C7526A  
C7527A  
C7529A  
C7530A  
C7534A  
C7540A  
0D1  
0D1  
0D1  
0D1  
0D1  
0D1  
0D1  
0D1  
0D1  
0D1  
0D1  
0D1  
0D1  
VA7110 Factory Rack  
A7294AZ  
A7296AZ  
Predefined SKU - VA7110 with Dual Controller, 2 GBICs, 1024-MB Cache (2×512MB DIMM)  
Predefined SKU - VA7110 with Dual Controller, 2 GBICs, 2048-MB Cache (2×1024MB DIMM)  
Field upgrade product. Select Virtual Array Controller (one or two) and cache (minimum 1024 MB) and disk options  
separately (factory installed). Field Installed. Includes enclosure assembly, user manual, and 2 power supplies, filler  
panels for controllers and disks.  
A6183AZ  
0D1  
A6186A  
A6187B  
0D1  
0D1  
1×512MB Cache for Virtual Array Controller, 1×512MB DIMM, StorageWorks VAP requires equal cache for both  
Controllers (if two are installed). Order 1 per installed VAP  
1×1024MB Cache for Virtual Array Controller, 1×1024MB DIMM, StorageWorks VAP requires equal cache for both  
Controllers (if two are installed). Order 1 per installed VAP  
A6192A  
A6193A  
A6194A  
A7288A  
A7289A  
C7524A  
0D1  
0D1  
0D1  
0D1  
0D1  
0D1  
36-GB 10K RPM FC HDD Module  
36-GB 15K RPM FC HDD Module  
73-GB 10K RPM FC HDD Module  
73-GB 15K RPM FC HDD Module  
146-GB 10K RPM FC HDD Module  
Fiber Optic Cable 2-meter LC 50/125 M/M  
4-104  
HP e3000 Business Servers Configuration Guide – Effective 1/04  
Information Subject to Change  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 4  
Peripherals and Accessories  
Product Number Option Number Description  
C7525A  
C7526A  
C7527A  
C7529A  
0D1  
0D1  
0D1  
0D1  
0D1  
Fiber Optic Cable 16-meter LC Duplex 50/125 M/M  
Fiber Optic Cable 50-meter LC Duplex 50/125 M/M  
Fiber Optic Cable 200-meter LC Duplex 50/125 M/M  
2-meter FC fiber optic cable M/M duplex LC-SC  
16-meter FC fiber optic cable M/M duplex LC-SC  
C7530A  
VA7110 Modules  
A7294AE  
A7296AE  
A6183AE  
A7293AE  
A6186A  
Predefined SKU - VA7110 with Dual Controller, 2 GBICs, 1024-MB Cache (2×512MB DIMM)  
Predefined SKU - VA7110 with Dual Controller, 2 GBICs, 2048-MB Cache (2×1024MB DIMM)  
Empty Enclosure  
Virtual Array Controller no memory installed (Note that single controller configurations are not supported!)  
1×512MB Cache for Virtual Array Controller, 1×512MB DIMM, StorageWorks VAP requires equal cache for both  
Controllers (if two are installed). Order 1 per installed VAP  
1×1024MB Cache for Virtual Array Controller, 1×1024MB DIMM, StorageWorks VAP requires equal cache for both  
Controllers (if two are installed). Order 1 per installed VAP  
36-GB 10K RPM FC HDD Module  
36-GB 15K RPM FC HDD Module  
73-GB 10K RPM FC HDD Module  
73-GB 15K RPM FC HDD Module  
146-GB 10K RPM FC HDD Module  
Optical Gigabit Interface Circuit (GBIC)  
2-meter FC fiber optic cable M/M multimode SC-SC  
16-meter FC fiber optic cable M/M multimode SC-SC  
50-meter FC fiber optic cable M/M multimode SC-SC  
100-meter FC fiber optic cable M/M multimode SC-SC  
2-meter FC fiber optic cable M/M duplex LC-SC  
16-meter FC fiber optic cable M/M duplex LC-SC  
FC fiber optic coupler F/F SC-SC  
FC adapter kit (includes C7529A and C7534A)  
A6187B  
A6192A  
A6193A  
A6194A  
A7288A  
A7289A  
A6203A  
A3583A  
A3531A  
A3735A  
A3736A  
C7529A  
C7530A  
C7534A  
C7540A  
VA7110 Rail Kits  
The following rail kits are needed to mount the VA7110 into the specific racks as listed.  
Part Number  
A6209A  
A6496A  
Description  
System/E Rail Kit (RoseBowl 2)  
NTRittal Rack rail kit  
A6244A  
HP Original rack rackmount hardware kit  
HP e3000 Business Servers Configuration Guide – Effective 1/04  
4-105  
Information Subject to Change  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 4  
Peripherals and Accessories  
VA7410 Controller Enclosure Hardware Ordering Information  
The following codes define the suffixes on product numbers: A = Field Racked, AE = Empty enclosure (no  
integration), AZ = Factory Racked.  
Order drives separately from the Enterprise Module section using the 0D1 option for integration. “AE”  
products are shipped as diskless enclosure only no integration (disks are ordered separately and field  
installed).  
Product  
Number  
Option  
Description  
VA7410 Enterprise Field RK SKU  
A6267A  
A6268A  
A6187B  
VA7410 with Dual Controller 1024-MB Cache Includes: VA Enclosure, (2) 2-Gbps/1-Gbps VA Cont Module Assy, (1) DIMM  
1,024-MB, User Guide, Installation Guide, Documentation Map, VA7x00 Documentation CD-ROM, (2) power cord, ESD Kit,  
RS-232 cable 9-9 pin, HP Command View SDM. Field upgrade product. Select Virtual Array Controller (one or two) and  
cache and disk options separately (factory installed). Field Installed. Includes enclosure assembly, user manual, and 2 power  
supplies, filler panels for controllers and disks.  
VA7410 with Dual Controller 2048-MB Cache Includes: VA Enclosure, (2) 2-Gbps/1-Gbps VA Cont Module Assy, (2) DIMM  
1,024-MB, User Guide, Installation Guide, Documentation Map, VA7x00 Documentation CD-ROM, (2) power cord, ESD Kit,  
RS-232 cable 9-9 pin, HP Command View SDM. Field upgrade product. Select Virtual Array Controller (one or two) and  
cache and disk options separately (factory installed). Field Installed. Includes enclosure assembly, user manual, and 2 power  
supplies, filler panels for controllers and disks.  
1 X 1024-MB Cache for Virtual Array Controller, 1 ×1024-MB DIMM, StorageWorks VAP requires equal cache for both  
Controllers (if 2nd installed). Order 1 per installed VAP  
A6191A  
A6192A  
A6193A  
A6194A  
A7288A  
A7289A  
0D1  
0D1  
0D1  
0D1  
0D1  
0D1  
Enterprise Class 18-GB 15K RPM FC HDD (minimum of 10 drives per array - sizes may be mixed)  
Enterprise Class 36-GB 10K RPM FC HDD (minimum of 10 drives per array - sizes may be mixed)  
Enterprise Class 36-GB 15K RPM FC HDD (minimum of 10 drives per array - sizes may be mixed)  
Enterprise Class 73-GB 10K RPM FC HDD (minimum of 10 drives per array - sizes may be mixed)  
Enterprise Class 73-GB 15K RPM FC HDD (minimum of 10 drives per array - sizes may be mixed) (VA7110 and VA7410 only)  
Enterprise Class 146-GB 10K RPM FC HDD (minimum of 10 drives per array - sizes may be mixed) (VA7110 and VA7410  
only)  
C7524A  
C7525A  
C7526A  
C7527A  
C7529A  
C7530A  
C7534A  
C7540A  
Fiber Optic Cable 2-meters LC 50/125 M/M  
Fiber Optic Cable 16-meters LC Duplex 50/125 M/M  
Fiber Optic Cable 50-meters LC Duplex 50/125 M/M  
Fiber Optic Cable 200-meters LC Duplex 50/125 M/M  
2-meter FC fiber optic cable M/M duplex LC-SC  
16-meter FC fiber optic cable M/M duplex LC-SC  
FC fiber optic coupler F/F SC-SC  
FC adapter kit (includes C7529A and C7534A)  
VA7410 Enterprise Factory Rack  
A6267AZ  
A6268AZ  
A6187B  
VA7410 with Dual Controller 1024-MB Cache Includes: VA Enclosure, (2) 2-Gbps/1-Gbps VA Cont Module Assy, (1) DIMM  
512-MB, User Guide, Installation Guide, Documentation Map, VA7x00 Documentation CD-ROM, (2) power cord, ESD Kit, RS-  
232 cable 9-9 pin, HP Command View SDM. Field upgrade product. Select Virtual Array Controller (one or two) and cache  
and disk options separately (factory installed). Field Installed. Includes enclosure assembly, user manual, and 2 power  
supplies, filler panels for controllers and disks.  
VA7410 with Dual Controller 2048-MB Cache Includes: VA Enclosure, (2) 2-Gbps/1-Gbps VA Cont Module Assy, (2) DIMM  
1024-MB, User Guide, Installation Guide, Documentation Map, VA7x00 Documentation CD-ROM, (2) power cord, ESD Kit,  
RS-232 cable 9-9 pin, HP Command View SDM. Field upgrade product. Select Virtual Array Controller (one or two) and  
cache and disk options separately (factory installed). Field Installed. Includes enclosure assembly, user manual, and 2 power  
supplies, filler panels for controllers and disks.  
1 X 1024-MB Cache for Virtual Array Controller, 1 ×10242MB DIMM, StorageWorks VAP requires equal cache for both  
Controllers (if 2nd installed). Order 1 per installed VAP  
A6191A  
A6192A  
A6193A  
A6194A  
A7288A  
A7289A  
0D1  
0D1  
0D1  
0D1  
0D1  
0D1  
Enterprise Class 18-GB 15K RPM FC HDD (minimum of 10 drives per array - sizes may be mixed)  
Enterprise Class 36-GB 10K RPM FC HDD (minimum of 10 drives per array - sizes may be mixed)  
Enterprise Class 36-GB 15K RPM FC HDD (minimum of 10 drives per array - sizes may be mixed)  
Enterprise Class 36-GB 15K RPM FC HDD (minimum of 10 drives per array - sizes may be mixed)  
Enterprise Class 73-GB 15K RPM FC HDD (minimum of 10 drives per array - sizes may be mixed) (VA7110 and VA7410 only)  
Enterprise Class 146-GB 10K RPM FC HDD (minimum of 10 drives per array - sizes may be mixed) (VA7110 and VA7410  
only)  
C7524A  
Fiber Optic Cable 2-meters LC 50/125 M/M  
4-106  
HP e3000 Business Servers Configuration Guide – Effective 1/04  
Information Subject to Change  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 4  
Peripherals and Accessories  
Product  
Number  
C7525A  
C7526A  
C7527A  
C7529A  
C7530A  
C7534A  
C7540A  
Option  
Description  
Fiber Optic Cable 162-meters LC Duplex 50/125 M/M  
Fiber Optic Cable 502-meters LC Duplex 50/125 M/M  
Fiber Optic Cable 2002-meters LC Duplex 50/125 M/M  
2-meter FC fiber optic cable M/M duplex LC-SC  
16-meter FC fiber optic cable M/M duplex LC-SC  
FC fiber optic coupler F/F SC-SC  
FC adapter kit (includes C7529A and C7534A)  
VA7410 Enterprise Modules  
A6267AE  
VA7410 with Dual Controller 1024-MB Cache Includes: VA Enclosure, (2) 2-Gbps/1-Gbps VA Cont Module Assy, (1) DIMM  
512-MB, User Guide, Installation Guide, Documentation Map, VA7x00 Documentation CD-ROM, (2) power cord, ESD Kit, RS-  
232 cable 9-9 pin, HP Command View SDM. Field upgrade product. Select Virtual Array Controller (one or two) and cache  
and disk options separately (factory installed). Field Installed. Includes enclosure assembly, user manual, and 2 power  
supplies, filler panels for controllers and disks.  
A6268AE  
VA7410 with Dual Controller 2048-MB Cache Includes: VA Enclosure, (2) 2-Gbps/1-Gbps VA Cont Module Assy, (2) DIMM  
1024-MB, User Guide, Installation Guide, Documentation Map, VA7x00 Documentation CD-ROM, (2) power cord, ESD Kit,  
RS-232 cable 9-9 pin, HP Command View SDM. Field upgrade product. Select Virtual Array Controller (one or two) and  
cache and disk options separately (factory installed). Field Installed. Includes enclosure assembly, user manual, and 2 power  
supplies, filler panels for controllers and disks.  
A6187B  
1×1024-MB Cache for Virtual Array Controller, 1×1024 2MB DIMM, StorageWorks VAP requires equal cache for both  
Controllers (if 2nd installed). Order 1 per installed VAP  
A6218A  
A6191A  
A6192A  
A6193A  
A6194A  
VA7410 Controller (minimum two required for VA7410)  
Enterprise Class 18-GB 15K RPM FC HDD (minimum of 10 drives per array - sizes may be mixed)  
Enterprise Class 36-GB 10K RPM FC HDD (minimum of 10 drives per array - sizes may be mixed)  
Enterprise Class 36-GB 15K RPM FC HDD (minimum of 10 drives per array - sizes may be mixed)  
Enterprise Class 73-GB 10K RPM FC HDD (minimum of 10 drives per array - sizes may be mixed)  
Enterprise Class 73-GB 15K RPM FC HDD (minimum of 10 drives per array - sizes may be mixed) (VA7110 and VA7410 only)  
Enterprise Class 146-GB 10K RPM FC HDD (minimum of 10 drives per array - sizes may be mixed) (VA7110 and VA7410  
only)  
A7288A  
A7289A  
0D1  
0D1  
C7524A  
C7525A  
C7526A  
C7527A  
C7529A  
C7530A  
C7534A  
C7540A  
Fiber Optic Cable 2-meters LC 50/125 M/M  
Fiber Optic Cable 16-meters LC Duplex 50/125 M/M  
Fiber Optic Cable 50-meters LC Duplex 50/125 M/M  
Fiber Optic Cable 200-meters LC Duplex 50/125 M/M  
2-meter FC fiber optic cable M/M duplex LC-SC  
16-meter FC fiber optic cable M/M duplex LC-SC  
FC fiber optic coupler F/F SC-SC  
FC adapter kit (includes C7529A and C7534A)  
VA7410 Rail Kits  
The following rail kits are needed to mount the VA7400 into the specific racks as listed.  
Part Number Description  
A6209A  
A6496A  
A6244A  
System/E Rail Kit (RoseBowl 2)  
NTRittal Rack Rail Kit  
HP Original rack rackmount hardware kit  
HP e3000 Business Servers Configuration Guide – Effective 1/04  
4-107  
Information Subject to Change  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 4  
Peripherals and Accessories  
Disk System Enclosure (DS2405) Hardware Ordering Information  
Note: The DS2405 cannot be used with the VA7100.  
The following codes define the suffixes on product numbers: A = Field Racked, AE = Empty enclosure (no  
integration), AZ = Factory Racked.  
Product  
Number  
Option Description  
DS2405 Disk Enclosure Field Rack  
A6250A  
A6250AE  
A6192A  
A6192A  
A6193A  
A6193A  
A6194A  
A6194A  
A7288A  
A7289A  
Disk System 2405 field rack enclosure (cables are not included and must be ordered separately)  
Disk System 2405 field rack enclosure with no disk integration (cables are not included and must be ordered separately)  
36-GB 10K RPM Fibre Channel drive add-on  
36-GB 10K RPM Fibre Channel drive installed into the enclosure (must order minimum quantity 2, maximum = 15)  
36-GB 15K RPM Fibre Channel drive add-on  
36-GB 15K RPM Fibre Channel drive installed into the enclosure (must order minimum quantity 2, maximum = 15)  
73-GB 10K RPM Fibre Channel drive add-on  
73-GB 10K RPM Fibre Channel drive installed into the enclosure (must order minimum quantity 2, maximum = 15)  
73-GB 15K RPM Fibre Channel drive installed into the enclosure (must order minimum quantity 2, maximum = 15)  
146-GB 10K RPM Fibre Channel drive installed into the enclosure (must order minimum quantity 2, maximum = 15, 7110 only)  
0D1  
0D1  
0D1  
0D1  
0D1  
DS2405 Disk Enclosure Factory Rack  
A6250AZ  
A6191A  
A6192A  
A6192A  
A6193A  
A6193A  
A6194A  
A6194A  
A7288A  
A7289A  
Disk System 2405 factory rack enclosure (cables are not included and must be ordered separately)  
18-GB 15K RPM Fibre Channel drive installed into the enclosure (must order minimum quantity 2, maximum = 15)  
36-GB 10K RPM Fibre Channel drive add-on  
36-GB 10K RPM Fibre Channel drive installed into the enclosure (must order minimum quantity 2, maximum = 15)  
36-GB 15K RPM Fibre Channel drive add-on  
36-GB 15K RPM Fibre Channel drive installed into the enclosure (must order minimum quantity 2, maximum = 15)  
73-GB 10K RPM Fibre Channel drive add-on  
73-GB 10K RPM Fibre Channel drive installed into the enclosure (must order minimum quantity 2, maximum = 15)  
73-GB 15K RPM Fibre Channel drive installed into the enclosure (must order minimum quantity 2, maximum = 15)  
146-GB 10K RPM Fibre Channel drive installed into the enclosure (must order minimum quantity 2, maximum = 15, 7110 only)  
0D1  
0D1  
0D1  
0D1  
0D1  
0D1  
Disk Enclosure Upgrades  
A6209A  
System/E Rail Kit  
A6496A  
NTRittal Rack rail kit  
A6244A  
HP Original rack rackmount hardware kit  
NOTES: A6183A requires rail kits to be ordered separately.  
Cache memory for VAP ordering note: You must order one and only one cache memory option type for each array.  
Fiber channel disk module ordering note: You must order at least two (2) but not more than fifteen (15) disk modules per enclosure. The unused slots must  
contain a disk slot filler panel to insure proper cooling of the array. The factory will include filler panels for any remaining open drive bays.  
DS2405 Disk System Accessories  
C7524A  
C7525A  
C7526A  
C7527A  
C7529A  
C7530A  
C7540A  
C7534A  
A6209A  
A6244A  
A6496A  
A6498A  
2-meter Fibre Channel cable LC 50/125 M/M  
16-meter Fibre Channel cable LC Duplex 50/125 M/M  
50-meter Fibre Channel cable LC Duplex 50/125 M/M  
200-meter Fibre Channel cable LC Duplex 50/125 M/M  
2-meter Fibre Channel cable LC/SC 50/125 M/M  
16-meter Fibre Channel cable LC/SC 50/125 M/M  
Fiber optic adapter kit  
Fiber optic coupler SC F/F  
System/E rack rail kit  
HP Original rack rackmount hardware kit  
NT/Rittal rack rail kit  
3U 2-post rail kit  
4-108  
HP e3000 Business Servers Configuration Guide – Effective 1/04  
Information Subject to Change  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 4  
Peripherals and Accessories  
VA7000 Family Racking and Rail Kit Options  
Note: Solution interconnect cabling/configuration of the A6264A/AZ and A6265A/AZ will be performed by  
the factory only when specified via Solution Integration Service Plan 2 (A3142B #002) with Visio Drawing  
attachment. Otherwise, data cables will ship with the solution, unconnected. (Please refer to  
Note: The VA7100 is not designed to be transported in the RoseBowl 1 or Rittal racks.  
HP Rack System/E Products  
Part Number  
A4900A  
A4901A  
Description  
Height  
Units  
25U  
33U  
41U  
HP Rack System/E25  
HP Rack System/E33  
HP Rack System/E41  
1.25 meters  
1.60 meters  
1.96 meters  
A4902A  
Compaq 9000 Rack Products  
Part Number  
9122  
9136  
Description  
Rack  
Rack  
Height  
Units  
22U  
36U  
42U  
1.1 meters  
1.7 meters  
2.0 meters  
9142  
Rack  
Support Options Overview  
Hardware Support Options  
CATS Upfront Support Options for Enterprise; Product Support Packs for Commercial Channel  
The following CATS and support pack options are available for the VA7000 Family. The support packs are on  
the disk system and contain the support pricing for the drives. CATS support, on the other hand, is ordered at  
the disk level. The following additional rules apply:  
Installation and start-up service is required and includes the following on the entire customer order:  
Pre-installation review  
Hardware installation  
Software enablement  
LUN design and implementation  
Customer documentation and orientation  
HP e3000 Business Servers Configuration Guide – Effective 1/04  
4-109  
Information Subject to Change  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 4  
Peripherals and Accessories  
Direct (Enterprise) CATS and Options 1  
Indirect (Commercial) Support Packs 1  
VA Hardware  
Universal Product  
Numbers  
Description  
1-, 2-, and 3-year  
Support: SD, 24×7,  
SCS, BCS  
Installation and  
Start-Up (H4726A)  
3-Year Support: SD,  
24×7  
Installation and  
Start-Up  
VA7100 Dual  
Controllers  
A6261A/AZ/AE;  
A6262A/AZ/AE,  
A6263A/AZ/AE  
VA7110 Dual  
Controllers  
Covers dual processors, 8AE  
cache, enclosure  
5CM  
5CP  
H7555A/E; H7559A/E  
H7561A/E; H7565A/E  
H7550A/E  
H7551A/E  
Covers dual processors, 8AF  
cache, enclosure  
A7294A/AZ/AE;  
A7295A/AZ/AE;  
A7296A/AZ/AE  
VA7410 Dual  
Controllers  
A6267A/AZ/AE;  
A6268A/AZ/AE  
Disk Enclosures  
A6214A/AZ/AE;  
A6183A/AZ/AE  
Covers dual processors, 8AF  
cache, enclosure  
5CP  
5CA  
H7561A/E; H7565A/E  
H7563A/E; H7564A/E  
H7551A/E  
H7558A/E  
Covers enclosure  
8AQ  
VA7100 Controller Covers processor, cache 803  
A6188A  
VA7110 Controller Covers processor, cache 803  
A7293A  
VA7410 Controller Covers processor, cache 803  
A6218A  
5CE  
5CF  
5CF  
5CG  
5CH  
5CJ  
5CJ  
5CJ  
H7569A/E; H7570A/E  
H7552A/E  
H7552A/E  
H7552A/E  
N/A  
H7567A/E; H7553A/E  
H7567A/E; H7553A/E  
18-GB HDD  
A6191A  
36-GB HDD  
A6913A, A6192A  
73-GB HDD  
A6194A  
73-GB HDD  
A7288A  
146-GB HDD  
A7289A  
N/A  
N/A  
N/A  
N/A  
N/A  
8AL  
8AN  
8AP  
8AP  
8AP  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
1
Direct channel (enterprise customers) purchase support on disks individually; support pack customers (“commercial” or indirect) receive coverage on up to 15 disks with  
purchase of enclosure or dual controller support packs.  
Note: CATS is the merger of the Camelot and Licensing 2000 projects into one overall program to “reinvent”  
HP’s upfront and contractual support structures. The internal program name is CATS, which stands for  
Camelot, Aries, Taurus, Scorpio (LS2K releases). For more information on CATS please see the URL at:  
http://nternet.fc.hp.com/catscore/channels.htm  
HP Service levels  
CATS Support  
Options-1 Year  
N/A  
CATS Support  
Options-2 Year  
N/A  
CATS Support  
Options-3 years  
N/A  
CATS Support  
Options-4 Year  
N/A  
CATS Support  
Options-5 Year  
N/A  
Same Day  
24 hours × 7 days  
Storage Critical Support VA  
BCS—4 hour  
H4404A/H4405A  
H4390A  
H4395A  
H4405J  
H4390J  
N/A  
H4404Y/H4405Y  
H4390Y  
N/A  
N/A  
H4390G  
N/A  
N/A  
H4390H  
N/A  
Call-to-Restoration  
4-110  
HP e3000 Business Servers Configuration Guide – Effective 1/04  
Information Subject to Change  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 4  
Peripherals and Accessories  
Hardware and Software—Additional Recommended Services  
TAS—H4399A/H4399J/H4399Y  
SAN Implementation Service for SAN environments—H9273A option 380, 381  
Additional Day ASE Time—H9273A option 311  
Service Guard Implementation—H4810AT  
HP StorageWorks Business Copy VA Implementation (Virtual Array)—H9273A option 3B2  
Contractual Support for Enterprise and Commercial Channels  
Support Suffixes (SPNs)  
02C  
02A  
02G  
02L  
02V  
02X  
07A  
07C  
07G  
07V  
07X  
SL2  
SL3  
Description of Services Offered  
The 02x are the post warranty support contractual monthly pricing available after the warranty. The 07x are  
the upgrade warranty support contractual monthly pricing available during the warranty.  
Below are the Service Levels:  
Code  
02A  
07A  
02C  
07C  
02G  
07G  
02L  
Description  
On-site 4 hour same day hardware response, Monday - Friday, business hours.  
07A is available as a warranty upgrade to an 02A response level  
On-site next day hardware response, Monday - Friday, business hours (vary by country).  
07C available as a warranty upgrade to an 02C response level  
On-site 4 hour same day hardware response, seven days a week, 24 hours a day.  
07G available as a warranty upgrade to an 02G response level  
On-site scheduled hardware response, Monday - Friday, business hours (vary by country).  
On-site six-hour hardware call-to-repair, seven days a week, 24 hours a day. Time begins when the original call to the call center is  
made. Recovery of operating system and other software are excluded from time commitment. Available only for customer sites up to  
50 miles (80 km) from a primary HP Support Response Office.  
02V  
07V  
02X  
07V available as a warranty upgrade to an 02V repair level  
On-site four-hour hardware call-to-restoration, seven days a week, 24 hours a day. Time begins when the original call to the call center  
is made. Restoration considered complete when an operating system prompt is re-established and the operating system is restored to  
the customer’s last configuration (or when the operating system is restored to a generic configuration for that operating system  
configuration). Time commitment does not include time needed for recovery of middleware, application software or data. Available only  
for customer sites up to 50 miles (80 km) from a primary HP Support Response Office. In order to purchase this level of response, the  
system must be part of a BCS contract.  
07X  
SL2  
SL3  
07X available as a warranty upgrade to an 02X repair level  
8×5 Phone-in assistance (Monday – Friday), 2 hour response, License to Use and updates  
24×7 Phone-in assistance, 2 hour response, License to Use and Updates  
Field Replaceable Units (FRUs)  
Dual Inline Memory Modules (DIMMs)  
Each controller utilizes one or two DIMMs, which contain battery-backed non-volatile RAM (NVRAM). The  
NVRAM is utilized for read/write caching and to store array memory maps. Because data is spread across all of  
the disks in the array, the array controller must have a way of determining where each block of data is located.  
This is accomplished using a logical-to-physical data map stored in NVRAM cache. This data map is vital to  
managing data; without it, all data in the array is inaccessible. Possible memory configurations are shown.  
HP e3000 Business Servers Configuration Guide – Effective 1/04  
4-111  
Information Subject to Change  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 4  
Peripherals and Accessories  
In a dual controller configuration, both controllers must have the same amount of cache memory as the  
contents of NVRAM are mirrored between the two controllers. This mirroring process insures that both  
controllers have exactly the same information in the event of a failure. The controller battery maintains  
NVRAM contents when normal power is not present. If the battery fails or loses its charge while power is off,  
the NVRAM contents are lost on that controller. To protect against data loss, the array power/standby switch  
turns off power to the array and the “Shutdown Operation” copies NVRAM contents to the disk drives in slots 1  
and 2 of the array. This allows reconstruction of the data in NVRAM if the original data is lost or corrupted.  
Note: When upgrading a VA7400 to a VA7410 or a VA7100 to a VA7110 or a VA7410, both DIMMs need to  
be the same part number (A6186-60002, for example).  
Note: The process of copying the contents of NVRAM to the two recovery disks makes the disk set  
independent of its controller. Because all the necessary mapping information is on these disks, it is  
possible to install a new controller or move the entire disk set to another controller. The new controller will  
determine that it has a new disk set, and the controller will attach itself to those disks.  
DIMM Sizes and Cache Sizes  
Array  
Minimum Cache  
256-MB/controller  
1024-MB/controller  
1024-MB / controller  
Maximum Cache  
1024-MB/controller  
2048-MB/controller  
2048-MB / controller  
VA7100  
VA7110  
VA7410  
Configurations of only one size DIMM in controllers are supported (for example, mixing 512-MB and 1024-MB DIMMs in the same controller is not supported).  
Slot 1 DIMM (MB)  
256-MB  
256-MB  
512-MB  
512-MB  
Slot 2 DIMM (MB)  
256-MB  
512-MB  
Total Memory (MB)  
256-MB  
512-MB  
512-MB  
1024-MB  
VA7100  
VA7110  
VA7410  
Y
Y
Y
Y
Y
N
N
N
N
Y*  
Y
N
N
N
Y*  
Y
1024-MB  
1024-MB  
1024-MB  
2048-MB  
1024-MB  
Y
Y
* This is a supported configuration, but new VA7110 controllers will not ship with 512-MB DIMMs.  
Battery  
Each array controller includes one battery to supply backup power to the DIMMs in the event have a power  
failure or if array power is switched off. If power is lost, the BATTERY LED will flash with a 5% duty cycle  
while it powers the DIMMs. The battery will maintain a charge for 3.5 days. If the battery loses its charge, or if  
it is removed from the controller, the DIMMs have no power and NVRAM contents are lost. A battery should  
be replaced when the software indicates a battery has failed.  
Early Warning Switch  
In a dual controller configuration, the NVRAM contents on both controllers are updated constantly. By  
maintaining a mirror image of the NVRAM, the secondary controller can take over immediately if the primary  
controller fails. If a dual controller needs to be replaced online, an early warning switch incorporated into the  
latch detects when the controller is being removed. Releasing the latch disables communication between  
controllers before power is lost to the controller being removed. This prevents corruption of the NVRAM  
contents.  
Disk Drives  
The array must have a minimum of four disk drives installed. Several types of disk drives can be installed in  
the array and capacities can be mixed within the array:  
18-GB Low-Profile Fibre Channel 15,000 rpm (supported, but no longer orderable)  
36-GB Low-Profile Fibre Channel 10,000 rpm  
36-GB Low-Profile Fibre Channel 15,000 rpm  
73-GB Low-Profile Fibre Channel 10,000 rpm  
73-GB Low-Profile Fibre Channel 15,000 rpm  
146-GB Low-Profile Fibre Channel 10,000 rpm (VA7410 and VA7110 arrays only)  
4-112  
HP e3000 Business Servers Configuration Guide – Effective 1/04  
Information Subject to Change  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 4  
Peripherals and Accessories  
The disk drives provide the storage medium for the disk array. A minimum of four disk modules is required to  
operate the disk array. Different capacity disk modules can be installed in the same array. A new disk can be  
added at any time, even while the disk array is operating. The array controller will recognize that a new disk  
has been added and will include the disk in the array configuration automatically if the Auto Include feature is  
enabled. To make the additional capacity available to the host, a new logical drive must be created, and the  
resulting drive must be configured into the operating system.  
Loading Rules  
VA7100  
Four (4) disks minimum and fifteen (15) disks maximum (4 of each type)  
VA7110  
Four (4) disks minimum and forty five (45) disks maximum (4 of each type)  
VA7410 disk loading rules:  
Ten (10) disk minimum per VA7410  
One hundred and five (105) disks maximum  
Four (4) disks minimum for each disk type that is installed, then user can add singles after that.  
DS2405 (disk enclosure) disk loading rules:  
Two (2) disk minimum  
Fifteen (15) disk maximum per DS2405  
Estimated Usable Capacity Tables  
Estimated Usable Capacity for RAID 1+0—VA7100  
This table lists the usable drive capacity, expressed in Gigabytes (GB), of the VA7100 with 36- and 73-GB drives  
with or without the use of hot spare drives.  
Capacity Table 1 GB = (1024)3 for RAID 1+0  
Drive size (GB)  
Hot Spares  
36 GB  
2
36 GB  
0
73 GB  
2
73 GB  
0
Number of drives  
Maximum usable capacity Maximum usable capacity Maximum usable capacity Maximum usable capacity  
in GB  
30.0  
45.2  
63.3  
80.0  
96.7  
146.8  
163.4  
180.1  
196.8  
213.5  
230.2  
246.9  
in GB  
63.3  
80.0  
96.7  
113.4  
130.1  
146.8  
163.4  
180.1  
196.8  
213.5  
230.2  
246.9  
in GB  
63.4  
95.4  
in GB  
130.2  
163.6  
197.1  
230.5  
263.9  
297.3  
330.7  
364.1  
397.5  
431.0  
464.4  
497.8  
4
5
6
7
8
9
10  
11  
12  
13  
14  
15  
130.2  
163.6  
197.1  
297.3  
330.7  
364.1  
397.5  
431.0  
464.4  
497.8  
HP e3000 Business Servers Configuration Guide – Effective 1/04  
4-113  
Information Subject to Change  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 4  
Peripherals and Accessories  
Capacity Table (GB) 1 GB =1,000,000,000 or (10)9 for RAID 1+0  
Drive size (GB)  
Hot Spares  
36 GB  
2
36 GB  
0
73 GB  
2
73 GB  
0
Number of drives  
Maximum usable capacity Maximum usable capacity Maximum usable capacity Maximum usable capacity  
in GB  
32.2  
48.6  
68.0  
in GB  
68.0  
85.9  
in GB  
68.1  
in GB  
139.8  
175.7  
211.6  
247.5  
283.4  
319.2  
355.1  
391.0  
426.9  
462.7  
498.6  
534.5  
4
5
6
7
8
9
10  
11  
12  
13  
14  
15  
102.4  
139.8  
175.7  
211.6  
319.2  
355.1  
391.0  
426.9  
462.7  
498.6  
534.5  
103.8  
121.8  
139.7  
157.6  
175.5  
193.4  
211.3  
229.3  
247.2  
265.1  
85.9  
103.8  
157.6  
175.5  
193.4  
211.3  
229.3  
247.2  
265.1  
Estimated Usable Capacity for AutoRAID—VA7100  
This table lists the usable drive capacity, expressed in Gigabytes (GB), of the VA7100 with 18-, 36-, and 73-GB  
drives and with or without the use of hot spare drives.  
Capacity Table 1 GB = (1024)3 for AutoRAID  
Drive size (GB)  
Hot Spares  
36 GB  
2
36 GB  
0
73 GB  
2
73 GB  
0
Number of drives  
Maximum usable capacity Maximum usable capacity Maximum usable capacity Maximum usable capacity  
in GB  
30.0  
45.2  
63.3  
in GB  
63.3  
93.4  
in GB  
63.4  
95.5  
in GB  
130.3  
192.6  
252.7  
314.4  
375.9  
437.3  
498.4  
558.9  
620.6  
681.7  
742.6  
803.5  
4
5
6
7
8
9
10  
11  
12  
13  
14  
15  
123.0  
153.9  
184.6  
215.2  
245.7  
276.3  
306.7  
337.2  
367.6  
398.0  
130.3  
192.6  
252.7  
314.4  
375.9  
437.3  
498.4  
558.9  
620.6  
681.7  
93.4  
123.0  
153.9  
184.6  
215.2  
245.7  
276.3  
306.7  
337.2  
Capacity Table (GB) 1 GB =1,000,000,000 or (10)9 for AutoRAID  
Drive size (GB)  
Hot Spares  
36 GB  
2
36 GB  
0
73 GB  
2
73 GB  
0
Number of drives  
Maximum usable capacity Maximum usable capacity Maximum usable capacity Maximum usable capacity  
in GB  
32.16  
48.56  
67.99  
in GB  
68.0  
in GB  
68.1  
in GB  
139.9  
206.8  
271.3  
337.6  
403.6  
469.5  
535.2  
600.1  
666.4  
732.0  
797.4  
862.8  
4
5
6
7
8
9
10  
11  
12  
13  
14  
15  
100.4  
132.2  
165.4  
198.4  
231.3  
264.1  
296.9  
329.6  
362.4  
395.1  
427.7  
102.5  
139.9  
206.8  
271.3  
337.6  
403.6  
469.5  
535.2  
600.1  
666.4  
732.0  
85.91  
103.83  
157.58  
175.50  
193.42  
211.34  
229.26  
247.17  
265.09  
4-114  
HP e3000 Business Servers Configuration Guide – Effective 1/04  
Information Subject to Change  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 4  
Peripherals and Accessories  
Estimated Usable Capacity for RAID 1+0—VA7110  
This table lists the usable drive capacity, expressed in Gigabytes (GB), of the VA7110 with 36-, 73-, and 146-GB  
drives with or without the use of hot spare drives.  
Capacity Table 1 GB  
Drive size (GB)  
Hot Spares  
36 GB  
2
36 GB  
0
73 GB  
2
73 GB  
0
146 GB  
2
146 GB  
0
Number of drives Maximum usable Maximum usable Maximum usable Maximum usable Maximum usable Maximum usable  
capacity in GB  
capacity in GB  
capacity in GB  
capacity in GB  
capacity in GB  
capacity in GB  
4
29  
58  
65  
130  
136  
273  
8
97  
133  
205  
277  
348  
420  
492  
563  
635  
707  
778  
796  
205  
420  
563  
707  
850  
993  
1137  
1280  
1423  
1567  
1603  
277  
420  
563  
707  
850  
993  
1137  
1280  
1423  
1567  
1603  
420  
850  
563  
850  
12  
16  
20  
24  
28  
32  
36  
40  
44  
45  
205  
277  
348  
420  
492  
563  
635  
707  
778  
796  
1137  
1423  
1710  
1997  
2284  
2570  
2857  
3144  
3215  
1137  
1423  
1710  
1997  
2284  
2570  
2857  
3144  
3215  
Estimated Usable Capacity for AutoRAID—VA7110  
This table lists the usable drive capacity, expressed in Gigabytes (GB), of the VA7110 with 36-, 73-, and 146-GB  
drives and with or without the use of hot spare drives.  
Capacity Table 1 GB  
Drive size (GB)  
Hot Spares  
36 GB  
2
36 GB  
0
73 GB  
2
73 GB  
0
146 GB  
2
146 GB  
0
Number of drives Maximum usable Maximum usable Maximum usable Maximum usable Maximum usable Maximum usable  
capacity in GB  
capacity in GB  
capacity in GB  
capacity in GB  
capacity in GB  
capacity in GB  
4
29  
58  
65  
130  
136  
273  
8
126  
186  
265  
391  
542  
800  
12  
16  
20  
24  
28  
32  
36  
40  
44  
45  
252  
383  
514  
644  
775  
905  
1036  
1166  
1296  
1329  
317  
448  
579  
710  
840  
970  
1101  
1231  
1362  
1394  
522  
784  
653  
915  
1036  
1587  
2110  
2632  
3154  
3676  
4197  
4719  
1325  
1849  
2371  
2893  
3415  
3937  
4458  
4980  
1046  
1307  
1568  
1829  
2089  
2350  
2611  
2676  
1176  
1437  
1698  
1959  
2220  
2481  
2741  
2807  
5240  
5371  
5501  
5631  
HP e3000 Business Servers Configuration Guide – Effective 1/04  
4-115  
Information Subject to Change  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 4  
Peripherals and Accessories  
GBIC (VA7100 only)  
A Gigabit Interface Converter (GBIC) is connected to each array controller as a transceiver for data and to  
convert the data from an optical signal to an electrical signal and vice versa. Each VAP includes a single GBIC.  
Based on user configurations, additional GBICs may be required. Only the GBICs A6203A (Enterprise) and  
A6241A (Commercial) are supported with the VA7100. These are Finisar GBICs, which provide readable serial  
number functionality.  
Redundant Power Supply and Fan Modules  
The array is shipped with two fully redundant power/fan modules. Each power/fan module contains:  
One load-sharing power supply which works in conjunction with the second power supply. The power  
supplies share the power load reciprocally; one supply automatically increases its output to compensate for  
reduced output from the other. If one power supply fails, the other supply delivers the entire load to  
maintain power for the array. If both power supplies fail, the controller will shutdown the array. Each  
power supply uses a separate power cord. Both power supplies can be plugged into a common power  
source, but it is recommended that each supply be plugged into a separate circuit to provide power source  
redundancy.  
Two internal fan modules provide cooling airflow and maintain the proper operating temperature for the  
entire array enclosure. If a fan fails, a fan fault will occur and the associated power supply will shut down.  
The other power supply will continue to operate and its associated fans will continue to cool the array.  
Also, if one power supply fails, both of its associated fans will continue to operate to cool the array.  
Note: During normal operation, if a failed power supply/fan module is removed, it must be replaced within  
two minutes to maintain proper cooling of the array. If a power/fan module slot is left empty, the airflow  
path will be disrupted and the array will overheat.  
Midplane  
The midplane, internal to the array enclosure, contains the following features for the identification of the array.  
This information is stored into redundant EEPROMs during the manufacturing process:  
Item  
Description  
World Wide Name (WWN)  
Default Fibre Channel Loop  
Addresses  
The Node WWN is used by the OS drivers to identify the array enclosure.  
The following default Fibre Channel loop addresses are assigned to array controllers: Array Controller 1: 108 Array  
Controller 2: 110  
The default Fibre Channel loop addresses can be changed using either the Virtual Front Panel (VPF) or the Command Line  
User Interface (CLUI) included with your HP Command View SDM software.  
NOTE: An array in a point-to-point configuration does not arbitrate for the bus, so no Fibre Channel loop addresses are required.  
Retains various operating parameters  
Same as the serial number sticker applied to the array  
Same as the product ID number (A6188A)  
Same as the product ID number (A7293A)  
Same the product ID number (A6218A)  
Product Mode Parameters  
Product Serial Number  
Product ID Number VA7100  
Product ID Number VA7110  
Product ID Number VA7410  
User installed licenses are stored within the Midplane EEPROM. These licenses are associated with a  
particular product serial number. If the Midplane must be replaced, a special Midplane may be ordered which,  
will allow the automatic regeneration of product serial number, licenses and product mode parameters. This  
information will be automatically re-programmed within the new Midplane EEPROMs if the replacement  
procedure is followed.  
LED Status Indications  
If a disk drive, controller, battery, DIMM, power supply or fan fails in the enclosure, a fault will be indicated by  
a fault (amber) LED on the module. The nature of the fault can be localized by examining the state of the  
LEDs.  
4-116  
HP e3000 Business Servers Configuration Guide – Effective 1/04  
Information Subject to Change  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 4  
Peripherals and Accessories  
Array Logs  
The array logs consist of the following controller logs:  
Events  
Errors  
Unexpected conditions  
Configuration changes  
Environmental changes  
Fibre Channel Port Statistics  
Historical Fibre Channel port information  
Performance  
Input/Output per second  
Flash  
Event log stored in flash memory in the event of a loss of battery power  
The array logs are stored in two (2) locations:  
The Controller(s).  
Host operating system: The HP Command View SDM software polls the array controller every 15 minutes  
and updates a host OS directory located on the host server internal disk drive. These logs contain “Event” data  
will be commonly accessed by the support entity HP Response Center.  
Note: The Fibre Channel Port Statistics and Performance log are stored in dynamic memory and will be  
lost when the array is powered off.  
Supported Operating Systems  
For Additional Information please see the Disk Storage Information located on the SPOCK web site:  
(http://hpso.rose.hp.com/spock/index.shtml#Disk_Storage_Information)  
HP-UX  
Windows NT  
Windows 2000  
Windows .NET (when available, VA7110 only)  
Linux  
Solaris—Requires management station  
AIX—Requires management station  
NetWare—Requires management station  
MPE/iX—Requires management station; requires HP SCSI-FC router (A5814A option 003) for Fibre Channel  
connectivity prior to MPE/iX 7.5; connectivity also supported via Native Fibre Channel in MPE/iX 7.5 or  
greater.  
For the latest configuration information, please refer to the SPOCK website (internal) or the Partnership  
Website (external):  
Spock Website:  
Partnership Website:  
HP e3000 Business Servers Configuration Guide – Effective 1/04  
4-117  
Information Subject to Change  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 4  
Peripherals and Accessories  
Supported Hardware Devices  
For the latest configuration information, please refer to the SPOCK website (internal) or the Partnership  
Website (external):  
Spock Website:  
Partnership Website:  
HBA Support  
For the latest configuration information, please refer to the SPOCK website (internal) or the Partnership  
Website (external):  
Spock Website:  
Partnership Website:  
Hub Support  
For the latest AutoPath support and configuration information, please refer to the SPOCK website (internal) or  
the Partnership Website (external):  
Spock Website:  
Partnership Website:  
Hub  
HP-UX  
10.20  
HP-UX  
11.00  
HP-UX  
11i  
NT  
NT  
Windows Windows Linux Red AIX 4.3.3 Solaris  
Netware  
Advanced Enterprise 2000  
2000  
Hat 6.2  
(32- and 2.6, 2.7,  
Server  
Edition  
Server  
Advanced  
Server  
Yes  
64-bit)  
2.8  
S10/L10  
Yes  
Yes  
Yes  
Yes  
Yes  
None  
FCI 1063  
and  
FC64-106  
3 only  
4-118  
HP e3000 Business Servers Configuration Guide – Effective 1/04  
Information Subject to Change  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 4  
Peripherals and Accessories  
Switch Support  
For the latest AutoPath support and configuration information, please refer to the SPOCK website (internal) or  
the Partnership Website (external):  
Spock Website:  
Partnership Website:  
Supported Disk Drives  
Part Number  
A6191A  
A6192A  
A6193A  
A6194A  
A7288A  
A7289A  
Description  
18-GB 15K RPM  
36-GB 10K RPM  
36-GB 15K RPM  
73-GB 10K RPM  
73-GB 15K RPM  
146-GB 10K RPM (VA7110 and VA7410 only)  
All Operating Systems  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Supported Fibre Channel Cables  
Product Number Description  
Optical LC/LC  
Usage  
A3583A  
A3531A  
A3735A  
A3735A  
C7524A  
Fiber optic cable, SC to SC, M/M, 2-meters (79 in)  
VA7100  
VA7100  
VA7100  
VA7100  
Fiber optic cable, SC to SC, M/M, 16-meters (52 ft)  
Fiber optic cable, SC to SC, M/M, 50-meters (164 ft)  
Fiber optic cable, SC to SC, M/M, 50-meters (164 ft)  
FC Cable 2-meter LC Duplex 50/125 M/M optical  
SFF1 (VA7110, VA7400, VA7410) to SFF FC Infrastructure (2  
GB/s FC)  
C7525A  
C7526A  
C7527A  
FC Cable 16-meter LC 50/125 LC/LC M/M optical  
FC Cable 50-meter LC Duplex 50/125 M/M optical  
FC Cable 200-meter LC Duplex 50/125 optical  
SFF1 (VA7110, VA7400, VA7410) to SFF FC Infrastructure (2  
GB/s FC)  
SFF1 (VA7110, VA7400, VA7410) to SFF FC Infrastructure (2  
GB/s FC)  
SFF1 (VA7110, VA7400, VA7410) to SFF FC Infrastructure (2  
GB/s FC)  
LC/SC Adapters  
C7529A  
C7530A  
C7534A  
C7540A  
FC Cable 2-meter LC/SC Duplex 50/125 M/M optical  
FC Cable 16-meter LC/SC Duplex 50/125 LC/LC M/M optical  
Fibre Channel SC F/F Extender Optical  
Fibre Channel Adapter Kit - optical (Includes the C7529A and  
C7534A)  
SFF1 (VA7400) to existing 1 GB/s FC Infrastructure  
SFF1 (VA7400) to existing 1 GB/s FC Infrastructure  
Converter for SFF cable to existing large format FC optical cables  
Kit for existing customer 1 GB/s FC infrastructure  
1 SFF = Small Form Factor  
HP e3000 Business Servers Configuration Guide – Effective 1/04  
4-119  
Information Subject to Change  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 4  
Peripherals and Accessories  
Configuration  
Front End and Back End Cabling  
Both front-end and back-end cables are Fibre Channel Optical cables.  
Figure 4.7.10.8 VA7110 Back End Cabling (Serial Connections)  
SC or SFF LC  
Optical  
Connectors  
Switch or host  
Switch or host  
SFF LC Optical  
Connectors  
Controller  
4
ADDRESS  
5
4
ADDRESS  
5
3
3
1
C  
CC  
A
IVE  
ACT  
IVE  
2
6
2
6
LI  
ACT  
N
I
C  
LI  
ACT  
N
I
K
VE  
PORT  
1
PORT  
LI  
ACT  
N
K
IV
LCC  
LI  
ACT  
N
K
IVE  
U  
L
T
FAU  
L
T
1
AL 100
0
FC
FC
0
FC-AL 100MB/s  
4
3
ADDRESS  
5
4
0
ADDRESS  
5
3
1
2
6
6
2
1
0
JBOD 1  
4
ADDRESS  
5
4
0
ADDRESS  
5
3
LCC  
3
1
CC  
IVE  
ACT  
IVE  
2
6
2
6
PORT  
0
LI  
N
C  
LI  
N
K
VE  
ORT  
1
PORT  
0
LI  
N
K
V
LCC  
LI  
N
K
VE  
ACT  
I
U  
L
T
ACT  
I
ACT  
I
FAU  
L
T
ACT  
I
1
F
0
FCL 0M  
Bs  
FC-L 0M  
Bs  
F-ABs  
4
3
ADDRESS  
5
4
0
ADDRESS  
5
3
1
2
6
6
2
1
0
JBOD 2  
Figure 4.7.10.9 VA7410 Back End Cabling (Serial Connections)  
4-120  
HP e3000 Business Servers Configuration Guide – Effective 1/04  
Information Subject to Change  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 4  
Peripherals and Accessories  
Long-Distance Configurations (Not supported on MPE/iX)  
Long-distance topologies are part of the supported configurations, but may not specifically be represented in  
this document. Long-distance scenarios may be obtained with the following configurations by replacing  
host/device connections with any of the combinations of hubs/switches as shown below. Hubs/switches may  
be cascaded no more than two layers deep and must meet the Fibre-Channel distance criteria (10,000- and 500-  
meter) for cables.  
Figure 4.7.1.10 Long-Distance Substitutions  
Hub/Switch  
Hub/Switch  
Hub/Switch  
Long-distance cascaded hubs must  
meet distance criteria and be no more  
than two layers deep.  
SAN Definitions  
Configurations in this document that include a SAN assume the following definition of a SAN or fabric:  
A dedicated network of servers and storage devices all connected to a fabric supporting block access  
technologies. For the purposes of this document, a fabric is defined as a hardware configuration containing at  
least one switch, which is responsible for frame routing.  
Open SAN is defined as heterogeneous (multiple vendor) servers and operating systems, heterogeneous  
storage, and heterogeneous infrastructure components. Pooled storage access is dependent on a LUN security  
methodology (zoning, partitioning, or dedicated LUN security) to provide data access by multiple  
heterogeneous servers. Multiple server access to common data is available only to homogeneous servers using  
server coordination software (e.g., MC/ServiceGuard for HP-UX and Cluster/iX for MPE/iX). Parallel server  
access is not supported on MPE/iX.  
SAN Characteristics:  
Utilizes a switch-based topology  
Allows cascaded switches  
Supports heterogeneous (multiple vendor) storage  
Switch based  
Heterogeneous server/OS capable  
Heterogeneous (multiple vendor) storage  
Fabric login  
Uses LUN Security or zoning  
Note: The SAN does not support common data access for heterogeneous servers.  
SAN Manager (management software):  
Requires fabric login  
Employs LUN Security or zoning  
HP e3000 Business Servers Configuration Guide – Effective 1/04  
4-121  
Information Subject to Change  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 4  
Peripherals and Accessories  
Figure 4.7.1.11 Lowest Entry Point (Minimum Configuration)  
MPE  
Management  
Station  
No Multi-Path driver required  
No hub or switch required  
Windows/HP-UX/Linux and MPE supported  
MPE requires Management Station  
If SCSI-FC is required then use A5814A option 003 for VA7100 or VA7X10  
Notes:  
Care must be taken to when attaching a management station running NT or  
Windows 2000. Deny any requests for MS disk signatures.  
LUN Security can eliminate the risk of MS disk signatures.  
Controller 1  
Controller 2  
Array  
Figure 4.7.1.12 Lowest Entry Point, Non-HA—Minimum Configuration (VA7410 only)  
Single HBA per host  
Dual controllers  
Management  
Station  
Supports Windows 2000,  
HP-UX/Linux, and MPE  
Requires LUN Security in a  
heterogeneous environment  
CommandView SDM required  
on one of the hosts  
MPE  
MPE  
MPE  
HBA  
HBA  
HBA  
HBA  
If SCSI-FC is required then use  
A5814A option 003 for VA7410  
Up to 4 host optional  
Controller 1  
Controller 2  
Array  
Figure 4.7.1.13 Entry-level Cluster with Path Redundancy—High Availability (VA7410 only)  
LUN Security recommended but not required  
Single HBA  
Two controllers set up with both personalities  
CommandView SDM required on the management  
station  
MPE  
HBA  
MPE  
HBA  
Management  
Station  
Notes:  
The VA7410 supports both 1 and 2 Gbps HBAs in the  
same host but the corresponding controller must be  
set to the same speed as the HBA (if the HBA does  
not support auto-negotiate). For example, if the HBA  
is set to 2 Gbps, the connected controller must also  
be set to 2Gbps.  
Controller 1  
Controller 2  
This configuration supports MPE’s Cluster/iX  
Array  
4-122  
HP e3000 Business Servers Configuration Guide – Effective 1/04  
Information Subject to Change  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 4  
Peripherals and Accessories  
Figure 4.7.1.14 Midrange Single-host with Failover/iX (unsupported for VA7100)  
Management  
Station  
MPE  
Dual HBA  
Dual controllers  
Dual switches recommended  
MPE Failover/iX required (unsupported for VA7100)  
Redundancy in storage paths  
Management Station required  
Switch  
If SCSI-FC is required then use A5814A option 003 for VA7410  
Note:  
Controller 1  
Controller 2  
If routers are used then use Single Initiator Zoning on the switches  
Array  
Figure 4.7.1.15 Midrange Multi-host with Failover/iX (VA7410 only)  
Management  
Station  
MPE  
MPE  
Dual HBA  
Dual controllers  
Dual switches  
MPE Failover/iX required (unsupported for VA7100)  
Redundancy in storage paths  
Management Station required  
Switch  
Switch  
If SCSI-FC is required then use A5814A option 003 for VA7410  
Note:  
If routers are used then use Single Initiator Zoning on the switches  
Controller 1  
Controller 2  
Array  
Figure 4.7.1.16 Simple Cluster with no Failover/iX (VA7410 only)  
Management  
Station  
MPE  
MPE  
Single HBA per host  
Dual controllers  
FC Switch  
SCSI-FC Router (A5814A option 003)  
SAN Manager software recommended  
MPE Cluster/iX required  
Management Station required  
Controller 1  
Controller 2  
Array  
HP e3000 Business Servers Configuration Guide – Effective 1/04  
4-123  
Information Subject to Change  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 4  
Peripherals and Accessories  
SAN Configurations  
Figure 4.7.1.17 Midrange Multi-host (Non-clustered) SAN with Optional Path Redundancy  
MPE  
Management  
Station  
MPE  
MPE  
Dual HBA  
Dual controllers  
Dual switches  
MPE Failover/iX required (unsupported for VA7100)  
Redundancy in storage paths  
Management Station required  
Switch  
Switch  
If SCSI-FC is required then use A5814A option 003 for VA7410  
Note:  
If routers are used then use Single Initiator Zoning on the switches  
Controller 1  
Controller 1  
Controller 2  
Controller 2  
Array  
Array  
Figure 4.7.1.18 A Typical SAN Configuration  
Management  
Station  
MPE  
MPE  
MPE  
Dual HBA  
Dual controllers  
Management Station required  
LUN Security is recommended if unfamiliar with managing the  
management station (disk signatures)  
Switch  
If SCSI-FC is required then use A5814A option 003 for VA7410  
Note:  
If routers are used then use Single Initiator Zoning on the switches  
Controller 1  
Controller 1  
Controller 2  
Controller 2  
Array  
Array  
4-124  
HP e3000 Business Servers Configuration Guide – Effective 1/04  
Information Subject to Change  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 4  
Peripherals and Accessories  
Figure 4.7.1.19 MPE/iX SAN Cluster  
Management  
Station  
MPE  
MPE  
Dual HBA  
Dual controllers  
Dual switches  
MPE Cluster/iX required (unsupported on VA7100)  
Management Station required  
Switch  
Switch  
If SCSI-FC is required then use A5814A option 003 for VA7410  
Note:  
If routers are used then use Single Initiator Zoning on the switches  
Controller 1  
Controller 1  
Controller 2  
Controller 2  
Array  
Array  
Figure 4.7.1.20 Heterogeneous Cluster in a SAN  
Windows  
Server  
HP-UX  
Server  
dedicated LAN  
connection  
dedicated LAN  
connection  
Windows  
Server  
HP-UX  
Server  
Requires fabric login  
Requires LUN Security support  
Single or Dual HBA  
Dual controllers  
Not Supported  
Requires multi-path driver  
SAN Manager software recommended  
Windows MSCS and MC/ServiceGuard  
Switch  
Switch  
1
2
1
2
VA7100  
VA7100  
HP e3000 Business Servers Configuration Guide – Effective 1/04  
4-125  
Information Subject to Change  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 4  
Peripherals and Accessories  
Figure 4.7.1.21 SAN Consolidation  
MPE  
Server  
HP-UX  
Server  
HP-UX  
Server  
MPE  
Server  
Requires LUN Security  
Single or Dual HBA  
Controllers setup with appropriate personalities  
(not supported on VA7100)  
Requires Failover/iX (MPE Not supported on VA7100)  
Requires Management Station  
Switch  
Switch  
If SCSI-FC is required then use A5814A option 003 for  
VA7XXX array  
Note:  
Controller 1  
Controller 1  
Controller 2  
Controller 2  
If routers are used then use Single Initiator Zoning on the  
switches  
Array  
Array  
Figure 4.7.1.22 Campus Cluster (Typical)  
Cable/Connection Legend  
SCSI HVD  
Fibre channel short-wave optical only  
LAN connection  
Networks  
Server  
Node 1  
Additional  
Nodes  
Server  
Node 2  
Additional  
Nodes  
Hub  
or  
Hub  
or  
Hub  
or  
Hub  
or  
Switch 1  
Switch 2  
Switch 3  
Switch 4  
1
2
1
2
Virtual Array 1  
Virtual Array 1  
(7100 with  
(7100 with  
0-6 DS2400  
Enclosures)  
0-6 DS2400  
Enclosures)  
Additional  
Arrays  
Additional  
Arrays  
Building 1  
Notes:  
Building 2  
MPE/iX 7.0 Express 1 requires management station and HP SCSI-FC router (A5814A option 003) for Fibre Channel connectivity. Native Fibre Channel  
supported in MPE/iX 7.5 or greater.  
Hubs and switches cannot be mixed in this configuration. They must be all hubs or all switches.  
Metro Cluster and Continental Cluster are not supported.  
4-126  
HP e3000 Business Servers Configuration Guide – Effective 1/04  
Information Subject to Change  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 4  
Peripherals and Accessories  
Software Product Descriptions  
Software Products Reference Chart  
The following table lists the software products available for the VA7000 Family. These products are described  
in detail later in this section.  
Software Product  
Source  
Description  
HP StorageWorks Command A single host license-to-use and Allows you to manage, diagnose, and monitor the performance of the array; used in  
View SDM  
software media kit ships with conjunction with value-added software products. Native OS support on HP-UX, Windows  
each VA7x00 Family product. NT, Windows 2000, Red Hat Linux, and with a separate management console on Solaris,  
Novell Netware, IBM AIX, and MPE. Additional host licenses must be purchased for each  
host running Command View SDM.  
HP StorageWorks Integrations Included with Command View Enables HP StorageWorks Command View SDM in HP OpenView NNM for HP-UX, Windows  
Pack  
SDM.  
2000 and Windows NT, also enables HP StorageWorks Command View SDM for  
HP TopTools, CA-Unicenter-TNG, Tivoli Netview and BMC Patrol. Includes/supports  
HP SEMI 1.0 for HP modular storage and tape devices.  
(Formerly Smart Plug-Ins)  
HP StorageWorks Business  
Copy VA  
HP StorageWorks Secure  
Manager VA  
Sold separately.  
Sold separately.  
Enables LUN copying within the array, and requires the same physical space to be available  
in the array as the LUN(s) being copied.  
Enables LUNs to be locked into a secure shared environment.  
HP StorageWorks Auto Path Sold separately.  
Enables I/O path fail-over in a single server for MSCS Windows 2000, Windows NT, HP-UX  
and Linux environments.  
HP StorageWorks Fast  
Recovery Solutions  
Sold separately.  
Allows for recovery of corrupted databases in minutes for Microsoft Exchange 2000 or SQL  
2000 environments. Requires Business Copy Virtual array  
Software Products  
Product Number  
Description  
T1086A  
HP StorageWorks Command View SDM 1 host License To Use and software media kit. Device management for the HP StorageWorks  
VA7x00 Family.  
T1003A  
HP StorageWorks Secure Manager, 50-GB host License To Use and software media kit. (Required for enablement) (Not combinable -  
50 GB max)  
T1004A  
T1005A  
T1006A  
T1007A  
HP StorageWorks Secure Manager 500-GB License To Use.  
HP StorageWorks Secure Manager 1-TB License To Use.  
HP StorageWorks Secure Manager 5-TB License To Use.  
HP StorageWorks Business Copy VA, 50-GB host License To Use and software media kit. (Required for enablement) (Not combinable -  
50 GB max)  
T1008A  
T1009A  
T1010A  
T1011A  
T1012A  
T1013A  
T1039A  
T1040A  
T1041A  
T1060A  
T1061A  
T1062A  
T1070A  
T1071A  
T1072A  
B9550A  
B9551A  
HP StorageWorks Business Copy VA 500-GB License To Use.  
HP StorageWorks Business Copy VA 1-TB License To Use.  
HP StorageWorks Business Copy VA 5-TB License To Use.  
HP StorageWorks Auto Path for Windows 2000 1-host License To Use and software media kit. (Required for enablement)  
HP StorageWorks Auto Path for Windows 2000 - 1-host License To Use.  
HP StorageWorks Auto Path for Windows 2000 - 5-host License To Use.  
HP StorageWorks Auto Path for Windows NT 4.0 - 1-host License To Use and software media kit. (Required for enablement)  
HP StorageWorks Auto Path for Windows NT 4.0 - 1-host License To Use.  
HP StorageWorks Auto Path for Windows NT 4.0 - 5-host License To Use.  
HP StorageWorks Auto Path for HP-UX 11.0, 11i - 1-host License To Use and software media kit. (Required for enablement)  
HP StorageWorks Auto Path for HP-UX 11.0, 11i - 1 -host License To Use.  
HP StorageWorks Auto Path for HP-UX 11.0, 11i - 5-host License To Use.  
HP StorageWorks Auto Path for Windows Server 2003 - software media kit. (Required for enablement)  
HP StorageWorks Auto Path for Windows Server 2003 - 1 -host License To Use.  
HP StorageWorks Auto Path for Windows Server 2003 - 5-host License To Use.  
HP StorageWorks Fast Recovery Solutions for Microsoft Exchange 2000 1 array based license to use capacity unlimited  
HP StorageWorks Fast Recovery Solutions for Microsoft SQL 2000 1 array based license to use capacity unlimited  
HP e3000 Business Servers Configuration Guide – Effective 1/04  
4-127  
Information Subject to Change  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 4  
Peripherals and Accessories  
HP StorageWorks Command View SDM Software  
The HP StorageWorks Command View SDM software is a host or Web-browser based device management  
application that provides a common user interface for modular networked storage systems.  
The HP StorageWorks Command View SDM software monitors and manages modular scaleable storage  
resources from a single systems management console or remotely via a Web browser with centralized control  
of their information resources. The HP StorageWorks Command View SDM software launches and configures  
HP value added software, such as HP StorageWorks Business Copy VA and HP StorageWorks Secure Manager  
VA. The HP StorageWorks Command View SDM software supports the HP StorageWorks VA 7000 family.  
Integrated device management platform and common user interface for all supported HP modular scaleable  
storage (arrays and disk systems)  
Java technology for ease of portability for support of new storage devices  
Active Graphic displays and status at glance features provides a comprehensive environment to monitor  
health and status with the highest efficiency and awareness.  
Common user interface (GUI, CLUI, CVUI and Web browser support) reduces training needs  
Network management and SANs integration for SAN network connectivity and device identification and  
event reporting to industry leading network management applications such as HP OpenView.  
Heterogeneous support  
HP StorageWorks Command View SDM Operating Systems Compatibility  
For operating system compatibility, please see “Supported Operating Systems” on page 4-117.  
HP StorageWorks Command View SDM Software Compatibility  
HP StorageWorks Command View SDM  
HP StorageWorks Integrations Pack  
HP StorageWorks Secure Manager  
HP StorageWorks Business Copy VA  
HP StorageWorks Command View SDM Minimum System Requirements  
Requires Internet Explorer 5.0; Netscape 4.74; Java Plug-In 1.3  
Need to add installation requirements for RAM  
Operating System  
CPU  
Memory  
Video  
Disk Space2  
Windows NT 4.0 (SP 6a)  
Windows 2000 (SP 1)  
Pentium III 500 MHz  
256 MB RAM  
1024×768 resolution,  
supports 64,000 colors  
120 MB of free disk space Performance  
Logs (2 months) 16 MB per LUN  
Windows Server 2003 (32-bit)  
HP-UX 11.0/11.11, 11.233  
All  
256 MB RAM  
256 MB RAM  
800×600 resolution,  
supports 64,000 colors  
1024×768 resolution,  
supports 64,000 colors  
120 MB of free disk space Performance  
Logs (2 months) 16 MB per LUN  
120 MB of free disk space Performance  
Logs (2 months) 16 MB per LUN  
Depends on management station (see  
above).  
Depends on management station (see  
above).  
Depends on management station (see  
above).  
Red Hat Linux 7.1, AS2.1  
MPE/iX 1  
Pentium III 500 MHz  
Depends on management Depends on management Depends on management  
station (see above). station (see above). station (see above).  
Depends on management Depends on management Depends on management  
station (see above). station (see above). station (see above).  
Depends on management Depends on management Depends on management  
station (see above). station (see above). station (see above).  
Depends on management Depends on management Depends on management  
Solaris 1  
Novell Netware 1  
IBM AIX 1  
Depends on management station (see  
above).  
station (see above).  
station (see above).  
station (see above).  
1 Requires dedicated management console and system requirements compatible with one of the above.  
2 30 MB of temporary disk space is required during installation. This space is returned after installation.  
3 HP-UX may require additional patches for proper operation.  
4-128  
HP e3000 Business Servers Configuration Guide – Effective 1/04  
Information Subject to Change  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 4  
Peripherals and Accessories  
The VA7x00 family system encompasses all the components within the controller chassis as well as the disks  
and their enclosures. The VA7x00 family Graphical User Interface (GUI) provides capabilities to retrieve single  
or multiple component status conditions and modify component states when applicable. The table lists all the  
components visible to the user. The first column denotes components that have their status queried and  
displayed by the GUI. The second column denotes components that the user can modify via the GUI.  
Note: This is the Command Line User Interface (CLUI) that is used for the VA7000 Family.  
Component Device Offerings  
Component  
Main Enclosure  
Batteries  
Controllers  
DIMMs  
Disks  
Fans  
GBICs  
Power Supplies  
Ports  
GUI provides capabilities to Query State  
GUI provides capabilities to Modify State  
3
JBODS  
Disks  
Fans  
LCC  
Power Supplies  
3 This does not reflect changing state of the controller, but rather modifying controller parameters.  
HP StorageWorks Command View SDM Frequently Asked Questions  
What is included with the standalone version of HP StorageWorks Command View SDM?  
Each Standalone version of HP StorageWorks Command View SDM includes:  
Software CD  
User’s Manual  
One Host License To Use  
This is defined as “Installation Authorization for one (1) Server” running any or all of the Command View SDM  
components listed above.  
Support is NOT INCLUDED with the Standalone version of HP StorageWorks Command View SDM. One (1)  
support option is required with each one (1) Host LTU of HP StorageWorks Command View SDM.  
Do I need HP StorageWorks Command View SDM installed on all hosts in a configuration order to  
access my VA?  
You must install HP StorageWorks Command View SDM on at least one (1) host with a fibre channel  
connection to the VA7100, VA7110 or VA7410. After your initial installation of HP StorageWorks Command  
View SDM, it is not necessary to install HP StorageWorks Command View SDM to access data on your VA.  
Is HP StorageWorks Command View SDM only required for management/configuration purposes?  
HP StorageWorks Command View SDM is only required for configuration and management of your HP VA.  
After your initial installation of HP StorageWorks Command View SDM, it is not necessary to install HP  
StorageWorks Command View SDM to access data on your VA.  
How many VA’s can HP StorageWorks Command View SDM manage at any given time?  
HP StorageWorks Command View SDM can manage an unlimited number of VA from a single host, provided  
that it is physically connected to each VA either directly or through a SAN  
HP e3000 Business Servers Configuration Guide – Effective 1/04  
4-129  
Information Subject to Change  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 4  
Peripherals and Accessories  
HP StorageWorks Integrations Pack  
HP StorageWorks Integrations Pack provide customers with a basic level of integration between HP  
StorageWorks Command View SDM and the leading network and systems management solutions enabling  
management from a single point—the enterprise management console. Integration is via SNMP (Simple  
Network Management Protocol) and enables customers to observe, diagnose and react to potential problems  
in their storage environment before they become serious enough to affect system availability.  
HP StorageWorks Integrations Pack Features  
Integration with HP OpenView NNM, HP TopTools, CA Unicenter-TNG, Tivoli Netview, and BMC Patrol  
Includes/supports HP SEMI 1.0 agent for HP modular storage and tape devices  
Plug and play installation  
Automated custom scripts  
Automatic discovery of supported storage devices by the network management application  
Device event communication via SNMP for Windows 2000 and NT 4.0 environments  
Changes in the status of the device are represented via the device icon that can launch the device software  
for further diagnostics or configuration status.  
Notes:  
HP StorageWorks Integrations Pack:  
are only supported on HP StorageWorks Command View SDM for modular networked storage. They are  
not supported on XP arrays  
do not support Red Hat Linux 6.2, 7.1.  
HP StorageWorks Integrations Pack Compatibility  
Supports HP SNMP integration for HP virtual arrays  
Supports HP OpenView Network Node Manager for HP-UX, Windows NT 4.0, and Windows 2000.  
Supports HP TopTools 4.5 and 5.0  
Supports CA Unicenter TNG for HP-UX, NT 4.0, and Windows 2000  
Supports HP StorageWorks VA7x00 Family  
Supports Tivoli Netview  
Supports BMC Patrol  
Supports HP SEMI 1.0 agent for HP modular storage and tape devices  
HP StorageWorks Integrations Pack Frequently Asked Questions  
What is included with HP StorageWorks Integrations Pack?  
Each HP StorageWorks Integrations Pack product includes:  
Software CD  
User’s Manual  
One Host License To Use (LTU)  
This is defined as “Installation Authorization for one (1) Server” running any or all of HP StorageWorks  
Integrations Pack components.  
Support is not included with this product. One (1) support option is required with each one (1) Host LTU for  
Enterprise Integrations.  
How does HP StorageWorks Command View SDM talk to OpenView Network Node-Manager using  
the HP StorageWorks Integrations Pack?  
HP StorageWorks Command View SDM tracks each connected VA7000 family array using a unique TCP-IP  
address. HP StorageWorks Command View SDM gets device information from each virtual array inband  
through the fibre channel connection and the HP StorageWorks Integrations Pack translate this information to  
OpenView Network Node Manager over TCP-IP using JVM and standard SNMP commands.  
4-130  
HP e3000 Business Servers Configuration Guide – Effective 1/04  
Information Subject to Change  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 4  
Peripherals and Accessories  
HP StorageWorks Business Copy VA  
HP StorageWorks Business Copy VA is an array-based software product that allows customers to create up to  
1023 non-disruptive high-performance, local business copies of any active application volume or LUN for the  
VA7000 family array within the array while benefiting from full RAID protection for the business copies. These  
LUN copies can be used by another application or system for a variety of purposes, including batch processing  
and backup. You can create up to 1023 Business Copy LUNs with the VA7000 family arrays. Business Copy VA  
is fully integrated into and enabled through the HP Command View SDM software interface.  
HP StorageWorks Business Copy VA is a vital piece of the Virtual Array Technology and is the key enabler of  
the virtual array online Backup solution, which is implemented using custom scripting of backup application  
environments.  
HP StorageWorks Business Copy VA Features  
Business critical data can be executed in parallel to enhance efficiency and cost effectiveness.  
Instantly creating point-in-time copies of source LUNs, scheduling backup activities, and maintaining I/O  
Host performance because all LUN creation and activity is handled directly by the array.  
HP StorageWorks Business Copy VA is fully integrated with Command View SDM.  
HP StorageWorks Business Copy VA Operating Systems Compatibility  
HP StorageWorks Business Copy VA runs with HP StorageWorks Command View SDM. For operating system  
compatibility, please see “Supported Operating Systems” on page 4-117.  
HP StorageWorks Business Copy VA Software Compatibility  
HP StorageWorks Command View SDM  
HP StorageWorks Integrations Pack  
HP StorageWorks Secure Manager  
HP StorageWorks Business Copy VA  
HP StorageWorks Business Copy VA Minimum System Requirements  
Operating System  
CPU  
Memory  
Disk Space  
Windows NT 4.0  
Pentium III 500-MHz  
256 MB RAM  
45 MB of free disk space.  
Windows 2000  
Windows Server 2003 (32 bit)  
HP-UX 11.0, 11.11, 11.23  
Red Hat Linux 7.1, AS2.1  
HP-UX 10.20 1  
All  
256 MB RAM  
256 MB RAM  
60 MB of free disk space.  
45 MB of free disk space  
Pentium III 500-MHz  
Depends on management station (see Depends on management station (see Depends on management station (see  
above). above). above).  
Depends on management station (see Depends on management station (see Depends on management station (see  
above). above). above).  
Depends on management station (see Depends on management station (see Depends on management station (see  
above). above). above).  
Depends on management station (see Depends on management station (see Depends on management station (see  
above). above). above).  
Depends on management station (see Depends on management station (see Depends on management station (see  
above). above). above).  
1 Requires dedicated management console and system requirements compatible with one of the above.  
MPE/iX 1  
Solaris 1  
Novell Netware 1  
IBM AIX 1  
Note: HP StorageWorks Business Copy VA supports a custom scripted implementation to automate backup  
solutions.  
HP e3000 Business Servers Configuration Guide – Effective 1/04  
4-131  
Information Subject to Change  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 4  
Peripherals and Accessories  
HP StorageWorks Business Copy VA Frequently Asked Questions  
What is included with HP StorageWorks Business Copy VA Software Media Kit?  
Each HP StorageWorks Business Copy VA software media kit includes:  
Software CD  
User’s Manual  
50-GB License To Use (not combinable - 50 GB max)  
90 days of telephone support  
In addition, to cover all capacity-based license-to-use options for HP StorageWorks Business Copy VA, one (1)  
support option is required.  
How does HP StorageWorks Business Copy VA Licensing work?  
In order to create HP StorageWorks Business Copy VA LUNs, a license must be obtained. Licensing is sold in  
quantities of 500 GB, 1 TB and 5 TB. The total size for all HP StorageWorks Business Copy VA LUNs cannot  
exceed the licensed amount for each virtual array.  
HP StorageWorks Business Copy VA licensing is based on the total size of all parent LUNs being copied, not  
the total array capacity. For example, in an array with total usable capacity of two (2) Terabytes, if you are  
copying one (1) Terabyte of parent LUN data you must purchase a one (1) Terabyte HP StorageWorks Business  
Copy VA license.  
Note: Licenses cannot span multiple arrays!  
Every VA7000 series array contains a 50-GB trial license. This is a permanent capability of the array and is  
intended to allow the trial of the feature before committing to the purchase. The trial copy can be used for the  
life of the product. This trial license is NOT additive.  
IS HP StorageWorks Business Copy VA supported for MPE/iX  
No. There are no plans to support HP StorageWorks Business Copy VA on MEP/iX.  
HP StorageWorks Secure Manager VA  
HP StorageWorks Secure Manager VA is an array-based software product that allows customers to create up to  
128 secure World Wide Name connections for the VA7000 family array on up to 1024 secure LUNs per virtual  
array. HP StorageWorks Secure Manager VA is fully integrated into and enabled through the HP Command  
View SDM software interface.  
HP StorageWorks Secure Manager VA is a storage software application that allows LUNs to be locked into  
secure protected volumes by World Wide Names, ensuring that only authorized World Wide Names (WWN)  
have access to restricted volumes. Permissions for each principal can be configured by volume within the  
virtual array to read only, read/write, or no access. The HP StorageWorks Secure Manager VA software’s  
supported configurations range from an entry-level single-server direct-connect environment up to a  
homogeneous or heterogeneous clustered environment.  
HP StorageWorks Secure Manager VA Features  
World Wide Names, host, and volume to enhance efficiency and cost effectiveness can secure business  
critical data in parallel.  
Configure security within the virtual array by changing permissions on volumes and/or World Wide Names  
(WWN) while the array is online.  
Uses the HP StorageWorks Command View SDM interface for establishing secure volumes.  
HP StorageWorks Secure Manager VA is fully integrated with HP StorageWorks Command View SDM and  
the VA family of hardware and software products for interoperability across the spectrum of future virtual  
array storage solutions.  
HP StorageWorks Secure Manager VA supports 128 secure World Wide Names for the VA7400. The  
HP StorageWorks Secure Manager VA software supports up to 1024 secure LUNs for each VA7000 family  
array.  
4-132  
HP e3000 Business Servers Configuration Guide – Effective 1/04  
Information Subject to Change  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 4  
Peripherals and Accessories  
HP StorageWorks Secure Manager VA Operating Systems Compatibility  
HP StorageWorks Secure Manager VA runs with HP StorageWorks Command View SDM. For operating system  
compatibility, please see “Supported Operating Systems” on page 4-117.  
HP StorageWorks Secure Manager VA Software Compatibility  
HP StorageWorks Command View SDM  
HP StorageWorks Integrations Pack  
HP StorageWorks Secure Manager  
HP StorageWorks Business Copy VA  
HP StorageWorks Secure Manager VA Minimum System Requirements  
Operating System  
Windows NT 4.0 and Windows  
2000  
CPU  
Memory  
256 MB RAM  
Disk Space  
45 MB of free disk space.  
Pentium III 500-MHz  
HP-UX 11.0, 11.1  
Red Hat Linux 6.2  
HP-UX 10.20  
All  
256 MB RAM  
256 MB RAM  
60 MB of free disk space.  
45 MB of free disk space  
Pentium III 500-MHz  
Depends on management station Depends on management station Depends on management station (see above).  
(see above). (see above).  
Depends on management station Depends on management station Depends on management station (see above).  
(see above). (see above).  
Depends on management station Depends on management station Depends on management station (see above).  
(see above). (see above).  
Depends on management station Depends on management station Depends on management station (see above).  
Solaris 2.6, 7.0, 8.0 1  
Novell Netware 5.0,5.1 1  
IBM AIX 4.3.3 1  
(see above).  
(see above).  
1 Requires dedicated management console and system requirements compatible with one of the above.  
HP StorageWorks Secure Manager VA Frequently Asked Questions  
What is included with HP StorageWorks Secure Manager VA Software Media Kit?  
Each HP StorageWorks Secure Manager VA software media kit includes:  
Software CD.  
User’s Manual.  
50-GB License To Use (LTU).  
90 days of telephone support.  
In addition, one support option is required for each capacity-based license-to-use option for HP  
StorageWorks Secure Manager VA.  
What does the term “principal” mean when used in HP StorageWorks Secure Manager VA?  
“Principal” and “World Wide Name” (WWN) are used interchangeably when describing secure connections for  
HP Virtual Arrays. All authentications for the VA7400 are based on WWN.  
How many secure connections can each VA7000 family array support?  
The VA7000 family array can support up to 128 secure Node WWN. Each Host Bus Adapter (HBA) uses a single  
Node WWN, therefore each VA7000 family array can support up to 1024 secure connections. Remember, for HA  
configurations, each server requires two HBAs so the largest HA configuration supported for each VA7000  
family array is a 16-node cluster.  
Can incremental capacity licenses be added over time?  
Yes, licenses are cumulative and additional licenses to may be added as capacity needs grow.  
HP StorageWorks Auto Path  
HP StorageWorks Auto Path VA is host-based software that provides key data availability and performance.  
HP StorageWorks Auto Path provides multi-path failover capability of all I/O data paths to the virtual array. HP  
StorageWorks Auto Path offers completely automatic HBA failover for all supported cluster environments.  
HP e3000 Business Servers Configuration Guide – Effective 1/04  
4-133  
Information Subject to Change  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 4  
Peripherals and Accessories  
Note: If a customer has met or is near the VA performance threshold, it is possible that high I/O demand  
(at 90% or greater of the VA threshold) may cause a performance degradation when running in a load-  
balancing configuration. Load balancing is not recommended for VA configurations that consistently  
require over 90% of the overall VA performance bandwidth!  
For the latest configuration information, please refer to the SPOCK website (internal) or the Partnership  
Website (external):  
Spock Website:  
Partnership Website:  
HP StorageWorks Auto Path Features  
Automatic error detection and failover: helps eliminate the need for planned and unplanned downtime.  
Works with Windows 2000 and Microsoft Cluster Server infrastructure.  
Works with Windows NT 4.0 and Microsoft Cluster Server infrastructure  
Works with HP-UX 11.0, 11i and MC/ServiceGuard infrastructure  
Supports the HP VA products that provide maximum performance and scalability.  
Automated configuration  
Management through a graphical user interface  
HP StorageWorks Auto Path Operating Systems Compatibility  
Please see “Supported Operating Systems” on page 4-117.  
HP StorageWorks Auto Path Software Compatibility  
HP StorageWorks Command View SDM  
HP StorageWorks Integrations Pack  
HP StorageWorks Secure Manager  
HP StorageWorks Business Copy VA  
HP StorageWorks Auto Path Minimum System Requirements  
Operating System  
Windows 2000, NT 4.0  
HP-UX 11.0, 11i  
CPU  
Memory  
256 MB RAM  
256 MB RAM  
Disk Space  
45 MB of free disk space.  
45 MB of free disk space.  
Pentium III- 500 MHZ  
All  
Note: HP StorageWorks Auto Path provides automatic I/O path failover only for Windows 2000,  
NT 4.0, and HP-UX 11.0, 11i.  
All HP software products are covered by a 90-day media defect warranty. All support options are sold  
separately.  
HP StorageWorks Auto Path Frequently Asked Questions  
What is included with HP StorageWorks Auto Path?  
Each HP StorageWorks Auto Path product includes:  
Software CD  
User’s Manual  
One (1) Host License To Use (LTU)  
This is defined as “Installation Authorization for one (1) Server” running any or all Auto Path components.  
Support is NOT included with this product. One (1) support option is required for each host-based  
license-to-use option for HP StorageWorks Auto Path.  
4-134  
HP e3000 Business Servers Configuration Guide – Effective 1/04  
Information Subject to Change  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 4  
Peripherals and Accessories  
What environments are available for HP StorageWorks Auto Path on the VA?  
HP StorageWorks Auto Path has planned availability of Windows 2000, Windows NT, and HP-UX with Red Hat  
Linux planned for future availability.  
HP StorageWorks Fast Recovery Solutions for Microsoft Exchange 2000 & SQL 2000  
HP StorageWorks Fast Recovery Solutions (FRS) is a tool designed to enable fast recovery of corrupt  
Exchange 2000 or SQL 2000 databases. FRS interacts with Windows 2000, Exchange 2000 or SQL server, and  
the disk array. The disk array stages recovery ready copies of Exchange 2000/SQL 2000 databases. When a  
catastrophic event occurs, the Exchange administrator initiates the FRS process. This process takes the  
damaged database offline, removes it and inserts the known good, recovery-ready copy on the production  
server. This process recovers the known good copy from disk rather than tape providing a full database  
recovery in minutes not hours.  
For the latest configuration information, please refer to the SPOCK website (internal) or the Partnership  
Website (external):  
Spock Website:  
Partnership Website:  
HP StorageWorks Fast Recovery Solutions Features  
Ultra-fast recovery of large Microsoft Exchange 2000 or SQL 2000 databases.  
Lowest possible downtime during a corruption and database recovery.  
Recovery to the last backup.  
Multiple databases can be recovered simultaneously.  
VA7000 Family Software Ordering Information  
HP StorageWorks VA Software Support Products  
Product Number  
Option  
Description  
T1086A  
HP StorageWorks Command View SDM Software Media Kit with - 1 Host License To Use  
One (1) software support warranty option required  
One (1) year software support  
Two (2) year software support  
Three (3) year software support  
H4403A/H4405A  
H4403J/H4405J  
H4405Y  
H4726A  
Software enablement, installation and customer demonstration service  
HP StorageWorks Integrations Pack for HP StorageWorks Command View SDM  
One (1) software support warranty option required  
One (1) year software support  
Two (2) year software support  
Three (3) year software support  
T1002A  
H4403A/H4405A  
H4403J/H4405J  
H4405Y  
H4726A  
Software enablement, installation and customer demonstration service  
HP StorageWorks Secure Manager VA Software Media Kit and 50 GB License To Use (required for  
enablement)  
90-day support included (Not combinable - 50 GB max)  
H4403A/H4405A  
H4403J/H4405J  
H4403Y/H4405Y  
H4726A  
N/A  
Two (2) year software support  
N/A  
N/A  
T1004A  
HP StorageWorks Secure Manager VA 500 GB License To Use  
One (1) software support warranty option required  
One (1) year software support  
H4403A/H4405A  
HP e3000 Business Servers Configuration Guide – Effective 1/04  
4-135  
Information Subject to Change  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 4  
Peripherals and Accessories  
Product Number  
Option  
Description  
H4403J/H4405J  
H4405Y  
Two (2) year software support  
Three (3) year software support  
H4726A  
Software enablement, installation and customer demonstration service  
HP StorageWorks Secure Manager VA - 1TB License To Use-One (1) software support warranty option  
required  
T1005A  
H4403A/H4405A  
H4403J/H4405J  
H4405Y  
One (1) year software support  
Two (2) year software support  
Three (3) year software support  
H4726A  
Software enablement, installation and customer demonstration service  
HP StorageWorks Secure Manager VA - 5 TB License To Use  
One (1) software support warranty option required  
One (1) year software support  
Two (2) year software support  
Three (3) year software support  
T1006A  
T1007A  
T1008A  
T1009A  
T1010A  
T1011A  
H4403A/H4405A  
H4403J/H4405J  
H4405Y  
H4726A  
Software enablement, installation and customer demonstration service  
HP StorageWorks Business Copy VA Software Media Kit and 50 GB License To Use (required for enablement)  
90-day support included (Not combinable - 50 GB max)  
N/A  
Two (2) year software support  
N/A  
H4403A/H4405A  
H4403J/H4405J  
H4403Y/H4405Y  
H4726A  
N/A  
HP StorageWorks Business Copy VA 500 GB License To Use  
One (1) software support warranty option required  
One (1) year software support  
Two (2) year software support  
Three (3) year software support  
Software enablement, installation and customer demonstration service  
HP StorageWorks Business Copy VA - 1 TB License To Use  
One (1) software support warranty option required  
One (1) year software support  
Two (2) year software support  
Three (3) year software support  
Software enablement, installation and customer demonstration service  
HP StorageWorks Business Copy VA - 5 TB License To Use  
One (1) software support warranty option required  
One (1) year software support  
Two (2) year software support  
Three (3) year software support  
Software enablement, installation and customer demonstration service  
HP StorageWorks Auto Path for Windows 2000 Software Media Kit and 1 Host License To Use (required for  
enablement)  
H4403A/H4405A  
H4403J/H4405J  
H4405Y  
H4726A  
H4403A/H4405A  
H4403J/H4405J  
H4405Y  
H4726A  
H4403A/H4405A  
H4403J/H4405J  
H4405Y  
H4726A  
One software support warranty option required  
H4403A/H4405A  
H4403J/H4405J  
H4405Y  
One (1) year software support  
Two (2) year software support  
Three (3) year software support  
H4726A  
Software enablement, installation and customer demonstration service  
HP StorageWorks Auto Path for Windows 2000 - 1 Host License To Use  
One (1) software support warranty option required  
One (1) year software support  
Two (2) year software support  
Three (3) year software support  
T1012A  
T1013A  
H4403A/H4405A  
H4403J/H4405J  
H4405Y  
H4726A  
Software enablement, installation and customer demonstration service  
HP StorageWorks Auto Path for Windows 2000 - 5 Host License To Use  
One (1) software support warranty option required  
One (1) year software support  
Two (2) year software support  
Three (3) year software support  
H4403A/H4405A  
H4403J/H4405J  
H4405Y  
4-136  
HP e3000 Business Servers Configuration Guide – Effective 1/04  
Information Subject to Change  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 4  
Peripherals and Accessories  
Product Number  
Option  
Description  
H4726A  
Software enablement, installation and customer demonstration service  
HP StorageWorks Auto Path for Windows NT 4.0 Software Media Kit and 1 Host License To Use (required for  
enablement)  
T1039A  
One (1) software support warranty option required  
H4403A/H4405A  
H4403J/H4405J  
H4405Y  
One (1) year software support  
Two (2) year software support  
Three (3) year software support  
H4726A  
Software enablement, installation and customer demonstration service  
HP StorageWorks Auto Path for Windows NT 4.0 - 1 Host License To Use  
One (1) software support warranty option required  
One (1) year software support  
Two (2) year software support  
Three (3) year software support  
T1040A  
T1041A  
T1042A  
T1043A  
T1060A  
T1061A  
T1062A  
T1070A  
T1071A  
H4403A/H4405A  
H4403J/H4405J  
H4405Y  
H4726A  
Software enablement, installation and customer demonstration service  
HP StorageWorks Auto Path for Windows NT 4.0 - 5 Host License To Use  
One (1) software support warranty option required  
One (1) year software support  
Two (2) year software support  
Three (3) year software support  
Software enablement, installation and customer demonstration service  
HP StorageWorks Auto Path for Windows NT 4.0 - 10 Host License To Use  
One (1) software support warranty option required  
One (1) year software support  
Two (2) year software support  
Three (3) year software support  
Software enablement, installation and customer demonstration service  
HP StorageWorks Auto Path for Windows NT 4.0 - 25 Host License To Use  
One (1) software support warranty option required  
One (1) year software support  
Two (2) year software support  
Three (3) year software support  
Software enablement, installation and customer demonstration service  
HP StorageWorks Auto Path for HP-UX 11.0,11i Software Media Kit and 1 Host License To Use (required for  
enablement) One (1) software support warranty option required  
One (1) year software support  
Two (2) year software support  
Three (3) year software support  
H4403A/H4405A  
H4403J/H4405J  
H4405J  
H4726A  
H4403A/H4405A  
H4403J/H4405J  
H4405Y  
H4726A  
H4403A/H4405A  
H4403J/H4405J  
H4405Y  
H4726A  
H4403A/H4405A  
H4403J/H4405J  
H4405Y  
H4726A  
Software enablement, installation and customer demonstration service  
HP StorageWorks Auto Path for HP-UX 11.0,11i 1 Host License To Use One (1) software support warranty  
option required  
One (1) year software support  
Two (2) year software support  
H4403A/H4405A  
H4403J/H4405J  
H4405Y  
Three (3) year software support  
H4726A  
Software enablement, installation and customer demonstration service  
HP StorageWorks Auto Path for HP-UX 11.0,11i - 5 Host License To Use One (1) software support warranty  
option required  
One (1) year software support  
Two (2) year software support  
H4403A/H4405A  
H4403J/H4405J  
H4405Y  
Three (3) year software support  
H4726A  
Software enablement, installation and customer demonstration service  
HP StorageWorks Auto Path for Windows Server 2003 Software Media Kit (required for enablement) One (1)  
software support warranty option required  
One (1) year software support  
Two (2) year software support  
Three (3) year software support  
Software enablement, installation and customer demonstration service  
HP StorageWorks Auto Path for Windows Server 2003 1 Host License To Use One (1) software support  
H4403A/H4405A  
H4403J/H4405J  
H4405Y  
H4726A  
HP e3000 Business Servers Configuration Guide – Effective 1/04  
4-137  
Information Subject to Change  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 4  
Peripherals and Accessories  
Product Number  
Option  
Description  
warranty option required  
H4403A/H4405A  
H4403J/H4405J  
H4405Y  
One (1) year software support  
Two (2) year software support  
Three (3) year software support  
H4726A  
Software enablement, installation and customer demonstration service  
T1072A  
HP StorageWorks Auto Path for Windows Server 2003 - 5 Host License To Use One (1) software support  
warranty option required  
H4403A/H4405A  
H4403J/H4405J  
H4405Y  
One (1) year software support  
Two (2) year software support  
Three (3) year software support  
H4726A  
Software enablement, installation and customer demonstration service  
B9550A  
B9551A  
HP StorageWorks Fast Recovery Solutions for Microsoft Exchange 2000 1 Array-based License to Use,  
capacity unlimited  
One (1) year software support  
Three (3) year software support  
H4403A/H4405A  
H4405Y  
HP StorageWorks Fast Recovery Solutions for Microsoft SQL 2000 1 Array-based License to Use, capacity  
unlimited  
H4403A/H4405A  
H4405Y  
One (1) year software support  
Three (3) year software support  
4-138  
HP e3000 Business Servers Configuration Guide – Effective 1/04  
Information Subject to Change  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 4  
Peripherals and Accessories  
Glossary  
Abbreviation  
Bps  
BE  
Description  
Bits per second  
Back End  
CLUI  
Cluster  
Command Line User Interface  
For the purposes of this document, a cluster is a configuration using two or more servers with failover capability. For  
HP-UX based configurations, this means running ServiceGuard. Windows-based cluster configurations incorporate the  
following characteristics: ·Windows Enterprise Edition for NT 4.0; Windows Advanced Server; Data Center Server for  
Windows 2000 (currently not released and not defined-this is an issue)  
Cluster-Aware  
Cluster-Safe  
Cluster-Supported  
Application is aware of cluster environment, informs the user a cluster exists, and provides additional cluster information  
Application does not prevent a MSCS cluster certification and does not create loss of data in a MSCS cluster environment  
Application is a transferable resource in a cluster; i.e., if a node in a cluster is taken off-line, the application will failover  
automatically to another cluster node.  
Data Center  
DR  
ESI  
Version of Windows 2000 OS that allows clustering of up to four servers.  
Design Release  
Enhanced Serial Interface  
ESN  
Fabric Login  
Enterprise Storage Network  
The name given to the initialization protocol for a device on the Storage Area Network (SAN) fabric with which it is  
“logged” into the SAN fabric. The act of “logging” provides the fabric with the required information about the device so  
that the device can be accessed and allows the device to access any other “fabric” device on the fabric.  
FE  
Fsam  
Front End  
Federated Storage Area Management  
GB  
GBIC  
Gigabyte(s)  
Gigabyte Interface Connector; plugged into the VA7100 controller to provide the optical interface to the host.  
Gbit  
GB/s  
Gigabit(s) (Note: HP standard says do not abbreviate as Gb.)  
Gigabits per second  
GHz  
GLM  
Gigahertz  
Gigabyte Link Module; generally associated with the HBA and the optical connection.  
GUI  
HBA  
Graphical User Interface  
Host Bus Adapter  
HCL  
Heterogeneous  
Hardware Compatibility List  
Dissimilar, differing in structure and quality  
JBOD  
I/O  
Storage/RAID Device (just a bunch of disks)  
Input/Output  
k
K
Kilo (prefix meaning 1,024)  
Kilo (prefix meaning 1,024)  
Kbit  
KB  
Kilobit (1,024 bits) (Note: HP standard says do not abbreviate as Kb.)  
Kilobyte (1,024 bytes)  
Kbps  
LUN  
Kilobytes per second  
Logical Unit Number (virtual disk)  
Mbit  
Mb/s  
Megabit  
Megabits per second  
MB  
MB/s  
Megabyte(s)  
Megabytes per second  
Windows MSCS  
Multi-path aware  
Multi-path driver  
RAID  
Windows software that coordinates two servers and directs the other server to take over when one fails.  
Ability to have knowledge of multiple paths to the storage device.  
Device driver that masks multiple access paths to a physical device. Ability to switch between paths.  
Redundant Array of Independent Disk  
Remote Management Capability Ability to launch management software from a remote location.  
RG  
SAN  
Redundancy Group  
Storage Area Network  
SCSI  
SDM  
Small Computer Standard Interface  
Storage Device Management  
SES  
ServiceGuard  
SFF  
SCSI Enclosure Services  
HP-UX software that coordinates two servers and directs the other server to take over when one fails.  
Small Form Factor  
VA  
VAP  
Virtual Array  
Virtual Array Controller  
WHQL  
WWN  
Windows MSCS  
Windows Hardware Quality Lab  
World Wide Name  
Microsoft Cluster Server - Windows software that coordinates two servers and directs the other server to take over  
when one fails.  
4.  
HP e3000 Business Servers Configuration Guide – Effective 1/04  
4-139  
Information Subject to Change  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Graco Thermostat 308791E User Manual
Grizzly Grinder H0589 User Manual
Harman Kardon Speaker System HKSB30BLK User Manual
Harman Speaker MS 10SD2 User Manual
Hasbro Robotics 83469 83463 User Manual
Heatcraft Refrigeration Products Air Compressor 25006801 User Manual
HP Hewlett Packard Computer Monitor 3535437 User Manual
HP Hewlett Packard PDAs Smartphones PC h1910 User Manual
Husqvarna Lawn Mower Accessory O0803001 User Manual
IBM Credit Card Machine OS User Manual