HP ProLiant MicroServer
Maintenance and Service Guide
Part number 615714-007
Seventh edition December 2012
Download from Www.Somanuals.com. All Manuals Search And Download.
Contents
Parts only warranty service ..........................................................................................................................5
Illustrated parts catalog.......................................................................................................................16
Mechanical components............................................................................................................................16
System components...................................................................................................................................21
HP contact information ..............................................................................................................................25
Before you contact HP ..........................................................................................................................25
Required tools...........................................................................................................................................26
Server warnings and cautions ....................................................................................................................26
Symbols on equipment ..............................................................................................................................28
Electrostatic discharge information..............................................................................................................29
Pre-installation procedure...........................................................................................................................29
Post-installation procedure..........................................................................................................................30
Powering down the server..........................................................................................................................30
Cable management...................................................................................................................................30
System cover ............................................................................................................................................32
Panel door ..........................................................................................................................................32
Top panel ...........................................................................................................................................33
Drive bay configuration.............................................................................................................................34
System drive cable management ...........................................................................................................34
Hard disk drive....................................................................................................................................36
Optical disc drive ................................................................................................................................38
System board configuration .......................................................................................................................42
Remove the system board .....................................................................................................................42
Install the system board ........................................................................................................................44
Processor ............................................................................................................................................47
Memory..............................................................................................................................................48
Expansion board .................................................................................................................................51
HP ProLiant MicroServer Remote Access Card.........................................................................................52
Installation guidelines...........................................................................................................................52
System battery.....................................................................................................................................54
System fan ..........................................................................................................................................55
Power supply unit......................................................................................................................................56
Installing the power supply unit..............................................................................................................57
User Diagnostics.......................................................................................................................................61
IPMI Event Log..........................................................................................................................................61
Reset the MicroServer Remote Access Card password to default ...............................................................61
Graceful shutdown function........................................................................................................................62
AMD RAIDXpert Utility...............................................................................................................................64
AMI BIOS software ...................................................................................................................................72
Configuring the system BIOS.................................................................................................................72
Setup Utility navigation keys .................................................................................................................73
Setup Utility menus...............................................................................................................................74
Summary screen ..................................................................................................................................79
Customer self repair
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Power-On-Self-Test................................................................................................................................80
Connectors and components......................................................................................................................84
Front panel..........................................................................................................................................84
Panel door components ........................................................................................................................85
Rear panel ..........................................................................................................................................85
System board ......................................................................................................................................87
System buttons and jumpers .......................................................................................................................88
System jumpers....................................................................................................................................88
Status LED indicators .................................................................................................................................89
External LED indicators .........................................................................................................................89
System specifications..........................................................................................................................90
Hardware specifications............................................................................................................................90
System unit..........................................................................................................................................90
Memory..............................................................................................................................................91
Power supply unit.................................................................................................................................91
Physical specifications...............................................................................................................................93
Environmental specifications.......................................................................................................................94
Customer self repair
4
Download from Www.Somanuals.com. All Manuals Search And Download.
Customer self repair
HP products are designed with many Customer Self Repair (CSR) parts to minimize repair time and
allow for greater flexibility in performing defective parts replacement. If during the diagnosis period
HP (or HP service providers or service partners) identifies that the repair can be accomplished by the
use of a CSR part, HP will ship that part directly to you for replacement. There are two categories of
CSR parts:
•
Mandatory—Parts for which customer self repair is mandatory. If you request HP to replace these
parts, you will be charged for the travel and labor costs of this service.
•
Optional—Parts for which customer self repair is optional. These parts are also designed for
customer self repair. If, however, you require that HP replace them for you, there may or may not
be additional charges, depending on the type of warranty service designated for your product.
NOTE: Some HP parts are not designed for customer self repair. In order to satisfy the customer
warranty, HP requires that an authorized service provider replace the part. These parts are identified
as "No" in the Illustrated Parts Catalog.
Based on availability and where geography permits, CSR parts will be shipped for next business day
delivery. Same day or four-hour delivery may be offered at an additional charge where geography
permits. If assistance is required, you can call the HP Technical Support Center and a technician will
help you over the telephone. HP specifies in the materials shipped with a replacement CSR part
whether a defective part must be returned to HP. In cases where it is required to return the defective
part to HP, you must ship the defective part back to HP within a defined period of time, normally five
(5) business days. The defective part must be returned with the associated documentation in the
provided shipping material. Failure to return the defective part may result in HP billing you for the
replacement. With a customer self repair, HP will pay all shipping and part return costs and
determine the courier/carrier to be used.
For more information about HP's Customer Self Repair program, contact your local service provider.
Parts only warranty service
Your HP Limited Warranty may include a parts only warranty service. Under the terms of parts only
warranty service, HP will provide replacement parts free of charge.
For parts only warranty service, CSR part replacement is mandatory. If you request HP to replace
these parts, you will be charged for the travel and labor costs of this service.
Customer self repair
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Réparation par le client (CSR)
Les produits HP comportent de nombreuses pièces CSR (Customer Self Repair = réparation par le
client) afin de minimiser les délais de réparation et faciliter le remplacement des pièces défectueuses.
Si pendant la période de diagnostic, HP (ou ses partenaires ou mainteneurs agréés) détermine que la
réparation peut être effectuée à l'aide d'une pièce CSR, HP vous l'envoie directement. Il existe deux
catégories de pièces CSR:
•
Obligatoire—Pièces pour lesquelles la réparation par le client est obligatoire. Si vous demandez
à HP de remplacer ces pièces, les coûts de déplacement et main d'œuvre du service vous seront
facturés.
•
Facultatif—Pièces pour lesquelles la réparation par le client est facultative. Ces pièces sont
également conçues pour permettre au client d'effectuer lui-même la réparation. Toutefois, si vous
demandez à HP de remplacer ces pièces, l'intervention peut ou non vous être facturée, selon le
type de garantie applicable à votre produit.
REMARQUE: Certaines pièces HP ne sont pas conçues pour permettre au client d'effectuer lui-même
la réparation. Pour que la garantie puisse s'appliquer, HP exige que le remplacement de la pièce soit
effectué par un Mainteneur Agréé. Ces pièces sont identifiées par la mention "Non" dans le
Catalogue illustré.
Les pièces CSR sont livrées le jour ouvré suivant, dans la limite des stocks disponibles et selon votre
situation géographique. Si votre situation géographique le permet et que vous demandez une
livraison le jour même ou dans les 4 heures, celle-ci vous sera facturée. Pour bénéficier d'une
assistance téléphonique, appelez le Centre d'assistance technique HP. Dans les documents envoyés
avec la pièce de rechange CSR, HP précise s'il est nécessaire de lui retourner la pièce défectueuse. Si
c'est le cas, vous devez le faire dans le délai indiqué, généralement cinq (5) jours ouvrés. La pièce et
sa documentation doivent être retournées dans l'emballage fourni. Si vous ne retournez pas la pièce
défectueuse, HP se réserve le droit de vous facturer les coûts de remplacement. Dans le cas d'une
pièce CSR, HP supporte l'ensemble des frais d'expédition et de retour, et détermine la société de
courses ou le transporteur à utiliser.
Pour plus d'informations sur le programme CSR de HP, contactez votre Mainteneur Agrée local. Pour
plus d'informations sur ce programme en Amérique du Nord, consultez le site Web HP
Service de garantie “pièces seules”
Votre garantie limitée HP peut inclure un service de garantie "pièces seules". Dans ce cas, les pièces
de rechange fournies par HP ne sont pas facturées.
Dans le cadre de ce service, la réparation des pièces CSR par le client est obligatoire. Si vous
demandez à HP de remplacer ces pièces, les coûts de déplacement et main d'œuvre du service vous
seront facturés.
Customer self repair
6
Download from Www.Somanuals.com. All Manuals Search And Download.
Riparazione da parte del cliente
Per abbreviare i tempi di riparazione e garantire una maggiore flessibilità nella sostituzione di parti
difettose, i prodotti HP sono realizzati con numerosi componenti che possono essere riparati
direttamente dal cliente (CSR, Customer Self Repair). Se in fase di diagnostica HP (o un centro di
servizi o di assistenza HP) identifica il guasto come riparabile mediante un ricambio CSR, HP lo
spedirà direttamente al cliente per la sostituzione. Vi sono due categorie di parti CSR:
•
Obbligatorie—Parti che devono essere necessariamente riparate dal cliente. Se il cliente ne
affida la riparazione ad HP, deve sostenere le spese di spedizione e di manodopera per il
servizio.
•
Opzionali—Parti la cui riparazione da parte del cliente è facoltativa. Si tratta comunque di
componenti progettati per questo scopo. Se tuttavia il cliente ne richiede la sostituzione ad HP,
potrebbe dover sostenere spese addizionali a seconda del tipo di garanzia previsto per il
prodotto.
NOTA: Alcuni componenti HP non sono progettati per la riparazione da parte del cliente. Per
rispettare la garanzia, HP richiede che queste parti siano sostituite da un centro di assistenza
autorizzato. Tali parti sono identificate da un "No" nel Catalogo illustrato dei componenti.
In base alla disponibilità e alla località geografica, le parti CSR vengono spedite con consegna entro
il giorno lavorativo seguente. La consegna nel giorno stesso o entro quattro ore è offerta con un
supplemento di costo solo in alcune zone. In caso di necessità si può richiedere l'assistenza telefonica
di un addetto del centro di supporto tecnico HP. Nel materiale fornito con una parte di ricambio CSR,
HP specifica se il cliente deve restituire dei componenti. Qualora sia richiesta la resa ad HP del
componente difettoso, lo si deve spedire ad HP entro un determinato periodo di tempo, generalmente
cinque (5) giorni lavorativi. Il componente difettoso deve essere restituito con la documentazione
associata nell'imballo di spedizione fornito. La mancata restituzione del componente può comportare
la fatturazione del ricambio da parte di HP. Nel caso di riparazione da parte del cliente, HP sostiene
tutte le spese di spedizione e resa e sceglie il corriere/vettore da utilizzare.
Per ulteriori informazioni sul programma CSR di HP contattare il centro di assistenza di zona. Per il
Servizio di garanzia per i soli componenti
La garanzia limitata HP può includere un servizio di garanzia per i soli componenti. Nei termini di
garanzia del servizio per i soli componenti, HP fornirà gratuitamente le parti di ricambio.
Per il servizio di garanzia per i soli componenti è obbligatoria la formula CSR che prevede la
riparazione da parte del cliente. Se il cliente invece richiede la sostituzione ad HP, dovrà sostenere le
spese di spedizione e di manodopera per il servizio.
Customer self repair
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Customer Self Repair
HP Produkte enthalten viele CSR-Teile (Customer Self Repair), um Reparaturzeiten zu minimieren und
höhere Flexibilität beim Austausch defekter Bauteile zu ermöglichen. Wenn HP (oder ein HP
Servicepartner) bei der Diagnose feststellt, dass das Produkt mithilfe eines CSR-Teils repariert werden
kann, sendet Ihnen HP dieses Bauteil zum Austausch direkt zu. CSR-Teile werden in zwei Kategorien
unterteilt:
•
Zwingend—Teile, für die das Customer Self Repair-Verfahren zwingend vorgegeben ist. Wenn
Sie den Austausch dieser Teile von HP vornehmen lassen, werden Ihnen die Anfahrt- und
Arbeitskosten für diesen Service berechnet.
•
Optional—Teile, für die das Customer Self Repair-Verfahren optional ist. Diese Teile sind auch
für Customer Self Repair ausgelegt. Wenn Sie jedoch den Austausch dieser Teile von HP
vornehmen lassen möchten, können bei diesem Service je nach den für Ihr Produkt vorgesehenen
Garantiebedingungen zusätzliche Kosten anfallen.
HINWEIS: Einige Teile sind nicht für Customer Self Repair ausgelegt. Um den Garantieanspruch des
Kunden zu erfüllen, muss das Teil von einem HP Servicepartner ersetzt werden. Im illustrierten
Teilekatalog sind diese Teile mit „No“ bzw. „Nein“ gekennzeichnet.
CSR-Teile werden abhängig von der Verfügbarkeit und vom Lieferziel am folgenden Geschäftstag
geliefert. Für bestimmte Standorte ist eine Lieferung am selben Tag oder innerhalb von vier Stunden
gegen einen Aufpreis verfügbar. Wenn Sie Hilfe benötigen, können Sie das HP technische Support
Center anrufen und sich von einem Mitarbeiter per Telefon helfen lassen. Den Materialien, die mit
einem CSR-Ersatzteil geliefert werden, können Sie entnehmen, ob das defekte Teil an HP
zurückgeschickt werden muss. Wenn es erforderlich ist, das defekte Teil an HP zurückzuschicken,
müssen Sie dies innerhalb eines vorgegebenen Zeitraums tun, in der Regel innerhalb von fünf (5)
Geschäftstagen. Das defekte Teil muss mit der zugehörigen Dokumentation in der Verpackung
zurückgeschickt werden, die im Lieferumfang enthalten ist. Wenn Sie das defekte Teil nicht
zurückschicken, kann HP Ihnen das Ersatzteil in Rechnung stellen. Im Falle von Customer Self Repair
kommt HP für alle Kosten für die Lieferung und Rücksendung auf und bestimmt den Kurier-
/Frachtdienst.
Weitere Informationen über das HP Customer Self Repair Programm erhalten Sie von Ihrem
Servicepartner vor Ort. Informationen über das CSR-Programm in Nordamerika finden Sie auf der HP
Parts-only Warranty Service (Garantieservice
ausschließlich für Teile)
Ihre HP Garantie umfasst möglicherweise einen Parts-only Warranty Service (Garantieservice
ausschließlich für Teile). Gemäß den Bestimmungen des Parts-only Warranty Service stellt HP
Ersatzteile kostenlos zur Verfügung.
Für den Parts-only Warranty Service ist das CSR-Verfahren zwingend vorgegeben. Wenn Sie den
Austausch dieser Teile von HP vornehmen lassen, werden Ihnen die Anfahrt- und Arbeitskosten für
diesen Service berechnet.
Customer self repair
8
Download from Www.Somanuals.com. All Manuals Search And Download.
Reparaciones del propio cliente
Los productos de HP incluyen muchos componentes que el propio usuario puede reemplazar
(Customer Self Repair, CSR) para minimizar el tiempo de reparación y ofrecer una mayor flexibilidad
a la hora de realizar sustituciones de componentes defectuosos. Si, durante la fase de diagnóstico,
HP (o los proveedores o socios de servicio de HP) identifica que una reparación puede llevarse a
cabo mediante el uso de un componente CSR, HP le enviará dicho componente directamente para
que realice su sustitución. Los componentes CSR se clasifican en dos categorías:
•
Obligatorio—Componentes para los que la reparación por parte del usuario es obligatoria. Si
solicita a HP que realice la sustitución de estos componentes, tendrá que hacerse cargo de los
gastos de desplazamiento y de mano de obra de dicho servicio.
•
Opcional—Componentes para los que la reparación por parte del usuario es opcional. Estos
componentes también están diseñados para que puedan ser reparados por el usuario. Sin
embargo, si precisa que HP realice su sustitución, puede o no conllevar costes adicionales,
dependiendo del tipo de servicio de garantía correspondiente al producto.
NOTA: Algunos componentes no están diseñados para que puedan ser reparados por el usuario.
Para que el usuario haga valer su garantía, HP pone como condición que un proveedor de servicios
autorizado realice la sustitución de estos componentes. Dichos componentes se identifican con la
palabra "No" en el catálogo ilustrado de componentes.
Según la disponibilidad y la situación geográfica, los componentes CSR se enviarán para que
lleguen a su destino al siguiente día laborable. Si la situación geográfica lo permite, se puede
solicitar la entrega en el mismo día o en cuatro horas con un coste adicional. Si precisa asistencia
técnica, puede llamar al Centro de asistencia técnica de HP y recibirá ayuda telefónica por parte de
un técnico. Con el envío de materiales para la sustitución de componentes CSR, HP especificará si los
componentes defectuosos deberán devolverse a HP. En aquellos casos en los que sea necesario
devolver algún componente a HP, deberá hacerlo en el periodo de tiempo especificado,
normalmente cinco días laborables. Los componentes defectuosos deberán devolverse con toda la
documentación relacionada y con el embalaje de envío. Si no enviara el componente defectuoso
requerido, HP podrá cobrarle por el de sustitución. En el caso de todas sustituciones que lleve a cabo
el cliente, HP se hará cargo de todos los gastos de envío y devolución de componentes y escogerá la
empresa de transporte que se utilice para dicho servicio.
Para obtener más información acerca del programa de Reparaciones del propio cliente de HP,
póngase en contacto con su proveedor de servicios local. Si está interesado en el programa para
Servicio de garantía exclusivo de componentes
La garantía limitada de HP puede que incluya un servicio de garantía exclusivo de componentes.
Según las condiciones de este servicio exclusivo de componentes, HP le facilitará los componentes de
repuesto sin cargo adicional alguno.
Para este servicio de garantía exclusivo de componentes, es obligatoria la sustitución de
componentes por parte del usuario (CSR). Si solicita a HP que realice la sustitución de estos
componentes, tendrá que hacerse cargo de los gastos de desplazamiento y de mano de obra de
dicho servicio.
Customer self repair
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Customer Self Repair
Veel onderdelen in HP producten zijn door de klant zelf te repareren, waardoor de reparatieduur tot
een minimum beperkt kan blijven en de flexibiliteit in het vervangen van defecte onderdelen groter is.
Deze onderdelen worden CSR-onderdelen (Customer Self Repair) genoemd. Als HP (of een HP
Service Partner) bij de diagnose vaststelt dat de reparatie kan worden uitgevoerd met een CSR-
onderdeel, verzendt HP dat onderdeel rechtstreeks naar u, zodat u het defecte onderdeel daarmee
kunt vervangen. Er zijn twee categorieën CSR-onderdelen:
•
Verplicht—Onderdelen waarvoor reparatie door de klant verplicht is. Als u HP verzoekt deze
onderdelen voor u te vervangen, worden u voor deze service reiskosten en arbeidsloon in
rekening gebracht.
•
Optioneel—Onderdelen waarvoor reparatie door de klant optioneel is. Ook deze onderdelen
zijn ontworpen voor reparatie door de klant. Als u echter HP verzoekt deze onderdelen voor u te
vervangen, kunnen daarvoor extra kosten in rekening worden gebracht, afhankelijk van het type
garantieservice voor het product.
OPMERKING: Sommige HP onderdelen zijn niet ontwikkeld voor reparatie door de klant. In
verband met de garantievoorwaarden moet het onderdeel door een geautoriseerde Service Partner
worden vervangen. Deze onderdelen worden in de geïllustreerde onderdelencatalogus aangemerkt
met "Nee".
Afhankelijk van de leverbaarheid en de locatie worden CSR-onderdelen verzonden voor levering op
de eerstvolgende werkdag. Levering op dezelfde dag of binnen vier uur kan tegen meerkosten
worden aangeboden, indien dit mogelijk is gezien de locatie. Indien assistentie gewenst is, belt u een
HP Service Partner om via de telefoon technische ondersteuning te ontvangen. HP vermeldt in de
documentatie bij het vervangende CSR-onderdeel of het defecte onderdeel aan HP moet worden
geretourneerd. Als het defecte onderdeel aan HP moet worden teruggezonden, moet u het defecte
onderdeel binnen een bepaalde periode, gewoonlijk vijf (5) werkdagen, retourneren aan HP. Het
defecte onderdeel moet met de bijbehorende documentatie worden geretourneerd in het
meegeleverde verpakkingsmateriaal. Als u het defecte onderdeel niet terugzendt, kan HP u voor het
vervangende onderdeel kosten in rekening brengen. Bij reparatie door de klant betaalt HP alle
verzendkosten voor het vervangende en geretourneerde onderdeel en kiest HP zelf welke
koerier/transportonderneming hiervoor wordt gebruikt.
Neem contact op met een Service Partner voor meer informatie over het Customer Self Repair
programma van HP. Informatie over Service Partners vindt u op de HP website
Garantieservice "Parts Only"
Het is mogelijk dat de HP garantie alleen de garantieservice "Parts Only" omvat. Volgens de
bepalingen van de Parts Only garantieservice zal HP kosteloos vervangende onderdelen ter
beschikking stellen.
Voor de Parts Only garantieservice is vervanging door CSR-onderdelen verplicht. Als u HP verzoekt
deze onderdelen voor u te vervangen, worden u voor deze service reiskosten en arbeidsloon in
rekening gebracht.
Customer self repair 10
Download from Www.Somanuals.com. All Manuals Search And Download.
Reparo feito pelo cliente
Os produtos da HP são projetados com muitas peças para reparo feito pelo cliente (CSR) de modo a
minimizar o tempo de reparo e permitir maior flexibilidade na substituição de peças com defeito. Se,
durante o período de diagnóstico, a HP (ou fornecedores/parceiros de serviço da HP) concluir que o
reparo pode ser efetuado pelo uso de uma peça CSR, a peça de reposição será enviada diretamente
ao cliente. Existem duas categorias de peças CSR:
•
Obrigatória—Peças cujo reparo feito pelo cliente é obrigatório. Se desejar que a HP substitua
essas peças, serão cobradas as despesas de transporte e mão-de-obra do serviço.
•
Opcional—Peças cujo reparo feito pelo cliente é opcional. Essas peças também são projetadas
para o reparo feito pelo cliente. No entanto, se desejar que a HP as substitua, pode haver ou
não a cobrança de taxa adicional, dependendo do tipo de serviço de garantia destinado ao
produto.
OBSERVAÇÃO: Algumas peças da HP não são projetadas para o reparo feito pelo cliente. A fim
de cumprir a garantia do cliente, a HP exige que um técnico autorizado substitua a peça. Essas
peças estão identificadas com a marca "No" (Não), no catálogo de peças ilustrado.
Conforme a disponibilidade e o local geográfico, as peças CSR serão enviadas no primeiro dia útil
após o pedido. Onde as condições geográficas permitirem, a entrega no mesmo dia ou em quatro
horas pode ser feita mediante uma taxa adicional. Se precisar de auxílio, entre em contato com o
Centro de suporte técnico da HP para que um técnico o ajude por telefone. A HP especifica nos
materiais fornecidos com a peça CSR de reposição se a peça com defeito deve ser devolvida à HP.
Nos casos em que isso for necessário, é preciso enviar a peça com defeito à HP dentro do período
determinado, normalmente cinco (5) dias úteis. A peça com defeito deve ser enviada com a
documentação correspondente no material de transporte fornecido. Caso não o faça, a HP poderá
cobrar a reposição. Para as peças de reparo feito pelo cliente, a HP paga todas as despesas de
transporte e de devolução da peça e determina a transportadora/serviço postal a ser utilizado.
Para obter mais informações sobre o programa de reparo feito pelo cliente da HP, entre em contato
com o fornecedor de serviços local. Para o programa norte-americano, visite o site da HP
Serviço de garantia apenas para peças
A garantia limitada da HP pode incluir um serviço de garantia apenas para peças. Segundo os
termos do serviço de garantia apenas para peças, a HP fornece as peças de reposição sem cobrar
nenhuma taxa.
No caso desse serviço, a substituição de peças CSR é obrigatória. Se desejar que a HP substitua
essas peças, serão cobradas as despesas de transporte e mão-de-obra do serviço.
Customer self repair 11
Download from Www.Somanuals.com. All Manuals Search And Download.
Customer self repair 12
Download from Www.Somanuals.com. All Manuals Search And Download.
Customer self repair 13
Download from Www.Somanuals.com. All Manuals Search And Download.
Customer self repair 14
Download from Www.Somanuals.com. All Manuals Search And Download.
Customer self repair 15
Download from Www.Somanuals.com. All Manuals Search And Download.
Item
1
Description
Spare part number
Customer self repair
Left panel
—
—
2
Bottom panel
System board tray
Health LED
—
—
3
—
—
4
—
—
5
Power button bracket
—
—
6
Front panel door
Right panel
624880-001
Optional2
7
—
—
Top panel
8
—
—
Cable bracket
Expansion slot cover
9
—
—
10
11
12
—
—
Chassis
—
—
Drive carrier
624879-001
Optional2
1Mandatory—Parts for which customer self repair is mandatory. If you request HP to replace these
parts, you will be charged for the travel and labor costs of this service.
2Optional—Parts for which customer self repair is optional. These parts are also designed for
customer self repair. If, however, you require that HP replace them for you, there may or may not be
additional charges, depending on the type of warranty service designated for your product.
3No—Some HP parts are not designed for customer self repair. In order to satisfy the customer
warranty, HP requires that an authorized service provider replace the part. These parts are identified
as "No" in the Illustrated Parts Catalog.
Illustrated parts catalog 17
Download from Www.Somanuals.com. All Manuals Search And Download.
1Mandatory: Obligatoire—Pièces pour lesquelles la réparation par le client est obligatoire. Si vous
demandez à HP de remplacer ces pièces, les coûts de déplacement et main d'œuvre du service vous
seront facturés.
2Optional: Facultatif—Pièces pour lesquelles la réparation par le client est facultative. Ces pièces sont
également conçues pour permettre au client d'effectuer lui-même la réparation. Toutefois, si vous
demandez à HP de remplacer ces pièces, l'intervention peut ou non vous être facturée, selon le type
de garantie applicable à votre produit.
3No: Non—Certaines pièces HP ne sont pas conçues pour permettre au client d'effectuer lui-même la
réparation. Pour que la garantie puisse s'appliquer, HP exige que le remplacement de la pièce soit
effectué par un Mainteneur Agréé. Ces pièces sont identifiées par la mention “Non” dans le
Catalogue illustré.
1Mandatory: Obbligatorie—Parti che devono essere necessariamente riparate dal cliente. Se il cliente
ne affida la riparazione ad HP, deve sostenere le spese di spedizione e di manodopera per il
servizio.
2Optional: Opzionali—Parti la cui riparazione da parte del cliente è facoltativa. Si tratta comunque
di componenti progettati per questo scopo. Se tuttavia il cliente ne richiede la sostituzione ad HP,
potrebbe dover sostenere spese addizionali a seconda del tipo di garanzia previsto per il prodotto.
3No: Non CSR—Alcuni componenti HP non sono progettati per la riparazione da parte del cliente.
Per rispettare la garanzia, HP richiede che queste parti siano sostituite da un centro di assistenza
autorizzato. Tali parti sono identificate da un “No” nel Catalogo illustrato dei componenti.
1Mandatory: Zwingend—Teile, die im Rahmen des Customer Self Repair Programms ersetzt werden
müssen. Wenn Sie diese Teile von HP ersetzen lassen, werden Ihnen die Versand- und Arbeitskosten
für diesen Service berechnet.
2Optional: Optional—Teile, für die das Customer Self Repair-Verfahren optional ist. Diese Teile sind
auch für Customer Self Repair ausgelegt. Wenn Sie jedoch den Austausch dieser Teile von HP
vornehmen lassen möchten, können bei diesem Service je nach den für Ihr Produkt vorgesehenen
Garantiebedingungen zusätzliche Kosten anfallen.
3No: Kein—Einige Teile sind nicht für Customer Self Repair ausgelegt. Um den Garantieanspruch des
Kunden zu erfüllen, muss das Teil von einem HP Servicepartner ersetzt werden. Im illustrierten
Teilekatalog sind diese Teile mit „No“ bzw. „Nein“ gekennzeichnet.
1Mandatory: Obligatorio—componentes para los que la reparación por parte del usuario es
obligatoria. Si solicita a HP que realice la sustitución de estos componentes, tendrá que hacerse
cargo de los gastos de desplazamiento y de mano de obra de dicho servicio.
2Optional: Opcional— componentes para los que la reparación por parte del usuario es opcional.
Estos componentes también están diseñados para que puedan ser reparados por el usuario. Sin
embargo, si precisa que HP realice su sustitución, puede o no conllevar costes adicionales,
dependiendo del tipo de servicio de garantía correspondiente al producto.
3No: No—Algunos componentes no están diseñados para que puedan ser reparados por el usuario.
Para que el usuario haga valer su garantía, HP pone como condición que un proveedor de servicios
autorizado realice la sustitución de estos componentes. Dichos componentes se identifican con la
palabra “No” en el catálogo ilustrado de componentes.
Illustrated parts catalog 18
Download from Www.Somanuals.com. All Manuals Search And Download.
1Mandatory: Verplicht—Onderdelen waarvoor Customer Self Repair verplicht is. Als u HP verzoekt
deze onderdelen te vervangen, komen de reiskosten en het arbeidsloon voor uw rekening.
2Optional: Optioneel—Onderdelen waarvoor reparatie door de klant optioneel is. Ook deze
onderdelen zijn ontworpen voor reparatie door de klant. Als u echter HP verzoekt deze onderdelen
voor u te vervangen, kunnen daarvoor extra kosten in rekening worden gebracht, afhankelijk van het
type garantieservice voor het product.
3No: Nee—Sommige HP onderdelen zijn niet ontwikkeld voor reparatie door de klant. In verband
met de garantievoorwaarden moet het onderdeel door een geautoriseerde Service Partner worden
vervangen. Deze onderdelen worden in de geïllustreerde onderdelencatalogus aangemerkt met
"Nee".
1Mandatory: Obrigatória—Peças cujo reparo feito pelo cliente é obrigatório. Se desejar que a HP
substitua essas peças, serão cobradas as despesas de transporte e mão-de-obra do serviço.
2Optional: Opcional—Peças cujo reparo feito pelo cliente é opcional. Essas peças também são
projetadas para o reparo feito pelo cliente. No entanto, se desejar que a HP as substitua, pode haver
ou não a cobrança de taxa adicional, dependendo do tipo de serviço de garantia destinado ao
produto.
3No: Nenhuma—Algumas peças da HP não são projetadas para o reparo feito pelo cliente. A fim de
cumprir a garantia do cliente, a HP exige que um técnico autorizado substitua a peça. Essas peças
estão identificadas com a marca “No” (Não), no catálogo de peças ilustrado.
Illustrated parts catalog 19
Download from Www.Somanuals.com. All Manuals Search And Download.
Illustrated parts catalog 20
Download from Www.Somanuals.com. All Manuals Search And Download.
Item
Description
Spare part number
—
Customer self repair
1
Drives
—
160 GB LFF SATA hard drive
250 GB LFF SATA hard drive
500 GB LFF SATA hard drive
Front USB assembly
483096-001
459315-001
459316-001
—
Optional2
Optional2
Optional2
—
2
3
4
IPMI card
624877-001
—
Optional2
Memory modules
—
Mandatory1
1 GB PC3-10600E UDIMM
2 GB PC3-10600E UDIMM
4 GB PC3-10600E UDIMM
PCIe card
501539-001
595101-001
595102-001
—
Mandatory1
Mandatory1
5
6
—
System board
—
—
System board with 1.3-GHz processor
System board with 1.5-GHz processor
System board with 2.2-GHz processor
System fan
620826-001
661787-001
708503-001
620828-001
—
Optional2
Optional2
Optional2
Mandatory1
—
7
8
Power supplies
150 W power supply
200 W power supply
DVD-RW drive
620827-001
625147-001
624592-001
Optional2
Optional2
Mandatory1
9
1Mandatory—Parts for which customer self repair is mandatory. If you request HP to replace these
parts, you will be charged for the travel and labor costs of this service.
2Optional—Parts for which customer self repair is optional. These parts are also designed for
customer self repair. If, however, you require that HP replace them for you, there may or may not be
additional charges, depending on the type of warranty service designated for your product.
3No—Some HP parts are not designed for customer self repair. In order to satisfy the customer
warranty, HP requires that an authorized service provider replace the part. These parts are identified
as "No" in the Illustrated Parts Catalog.
1Mandatory: Obligatoire—Pièces pour lesquelles la réparation par le client est obligatoire. Si vous
demandez à HP de remplacer ces pièces, les coûts de déplacement et main d'œuvre du service vous
seront facturés.
2Optional: Facultatif—Pièces pour lesquelles la réparation par le client est facultative. Ces pièces sont
également conçues pour permettre au client d'effectuer lui-même la réparation. Toutefois, si vous
Illustrated parts catalog 22
Download from Www.Somanuals.com. All Manuals Search And Download.
demandez à HP de remplacer ces pièces, l'intervention peut ou non vous être facturée, selon le type
de garantie applicable à votre produit.
3No: Non—Certaines pièces HP ne sont pas conçues pour permettre au client d'effectuer lui-même la
réparation. Pour que la garantie puisse s'appliquer, HP exige que le remplacement de la pièce soit
effectué par un Mainteneur Agréé. Ces pièces sont identifiées par la mention “Non” dans le
Catalogue illustré.
1Mandatory: Obbligatorie—Parti che devono essere necessariamente riparate dal cliente. Se il cliente
ne affida la riparazione ad HP, deve sostenere le spese di spedizione e di manodopera per il
servizio.
2Optional: Opzionali—Parti la cui riparazione da parte del cliente è facoltativa. Si tratta comunque
di componenti progettati per questo scopo. Se tuttavia il cliente ne richiede la sostituzione ad HP,
potrebbe dover sostenere spese addizionali a seconda del tipo di garanzia previsto per il prodotto.
3No: Non CSR—Alcuni componenti HP non sono progettati per la riparazione da parte del cliente.
Per rispettare la garanzia, HP richiede che queste parti siano sostituite da un centro di assistenza
autorizzato. Tali parti sono identificate da un “No” nel Catalogo illustrato dei componenti.
1Mandatory: Zwingend—Teile, die im Rahmen des Customer Self Repair Programms ersetzt werden
müssen. Wenn Sie diese Teile von HP ersetzen lassen, werden Ihnen die Versand- und Arbeitskosten
für diesen Service berechnet.
2Optional: Optional—Teile, für die das Customer Self Repair-Verfahren optional ist. Diese Teile sind
auch für Customer Self Repair ausgelegt. Wenn Sie jedoch den Austausch dieser Teile von HP
vornehmen lassen möchten, können bei diesem Service je nach den für Ihr Produkt vorgesehenen
Garantiebedingungen zusätzliche Kosten anfallen.
3No: Kein—Einige Teile sind nicht für Customer Self Repair ausgelegt. Um den Garantieanspruch des
Kunden zu erfüllen, muss das Teil von einem HP Servicepartner ersetzt werden. Im illustrierten
Teilekatalog sind diese Teile mit „No“ bzw. „Nein“ gekennzeichnet.
1Mandatory: Obligatorio—componentes para los que la reparación por parte del usuario es
obligatoria. Si solicita a HP que realice la sustitución de estos componentes, tendrá que hacerse
cargo de los gastos de desplazamiento y de mano de obra de dicho servicio.
2Optional: Opcional— componentes para los que la reparación por parte del usuario es opcional.
Estos componentes también están diseñados para que puedan ser reparados por el usuario. Sin
embargo, si precisa que HP realice su sustitución, puede o no conllevar costes adicionales,
dependiendo del tipo de servicio de garantía correspondiente al producto.
3No: No—Algunos componentes no están diseñados para que puedan ser reparados por el usuario.
Para que el usuario haga valer su garantía, HP pone como condición que un proveedor de servicios
autorizado realice la sustitución de estos componentes. Dichos componentes se identifican con la
palabra “No” en el catálogo ilustrado de componentes.
1Mandatory: Verplicht—Onderdelen waarvoor Customer Self Repair verplicht is. Als u HP verzoekt
deze onderdelen te vervangen, komen de reiskosten en het arbeidsloon voor uw rekening.
2Optional: Optioneel—Onderdelen waarvoor reparatie door de klant optioneel is. Ook deze
onderdelen zijn ontworpen voor reparatie door de klant. Als u echter HP verzoekt deze onderdelen
Illustrated parts catalog 23
Download from Www.Somanuals.com. All Manuals Search And Download.
voor u te vervangen, kunnen daarvoor extra kosten in rekening worden gebracht, afhankelijk van het
type garantieservice voor het product.
3No: Nee—Sommige HP onderdelen zijn niet ontwikkeld voor reparatie door de klant. In verband
met de garantievoorwaarden moet het onderdeel door een geautoriseerde Service Partner worden
vervangen. Deze onderdelen worden in de geïllustreerde onderdelencatalogus aangemerkt met
"Nee".
1Mandatory: Obrigatória—Peças cujo reparo feito pelo cliente é obrigatório. Se desejar que a HP
substitua essas peças, serão cobradas as despesas de transporte e mão-de-obra do serviço.
2Optional: Opcional—Peças cujo reparo feito pelo cliente é opcional. Essas peças também são
projetadas para o reparo feito pelo cliente. No entanto, se desejar que a HP as substitua, pode haver
ou não a cobrança de taxa adicional, dependendo do tipo de serviço de garantia destinado ao
produto.
3No: Nenhuma—Algumas peças da HP não são projetadas para o reparo feito pelo cliente. A fim de
cumprir a garantia do cliente, a HP exige que um técnico autorizado substitua a peça. Essas peças
estão identificadas com a marca “No” (Não), no catálogo de peças ilustrado.
Illustrated parts catalog 24
Download from Www.Somanuals.com. All Manuals Search And Download.
HP contact information
For United States and worldwide contact information, see the Contact HP website
In the United States:
•
To contact HP by phone, call 1-800-334-5144. For continuous quality improvement, calls may
be recorded or monitored.
•
If you have purchased a Care Pack (service upgrade), see the Support & Drivers website
website, call 1-800-633-3600. For more information about Care Packs, see the HP website
Before you contact HP
Be sure to have the following information available before you call HP:
•
Active Health System log (HP ProLiant Gen8 or later products)
Download and have available an Active Health System log for 3 days before the failure was
detected. For more information, see the HP iLO 4 User Guide for HP Intelligent Provisioning User
•
•
•
•
•
•
•
•
Technical support registration number (if applicable)
Product serial number (printed on the serial pull tab located on the front panel)
Product model name and number
Product identification number
Applicable error messages
Add-on boards or hardware
Third-party hardware or software
Operating system type and revision level
Illustrated parts catalog 25
Download from Www.Somanuals.com. All Manuals Search And Download.
Removal and replacement procedures
Required tools
In performing any hardware configuration procedure you may need the following tools:
•
System screwdriver (secured to the front panel door)
All hardware screws used in the server can be removed or fastened by using the system
screwdriver.
•
All spare screws are located on the back side of the front panel door.
The following references and software tools may also be used:
•
•
IPMI Event Log
Diagnostics software
Server warnings and cautions
Before installing a server, be sure that you understand the following warnings and cautions.
WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the internal
system components to cool before touching them.
CAUTION: The server must always be operated with the system covers on. Proper cooling is not
achieved when the system covers are removed.
CAUTION: Whenever installing hardware or performing maintenance procedures requiring access
to internal components, it is recommended that users first back up all server data to avoid loss.
Removal and replacement procedures 26
Download from Www.Somanuals.com. All Manuals Search And Download.
IMPORTANT: Before removing any serviceable parts, determine whether the part is hot-plug or
non-hot-plug. If the device is non-hot-plug, you must power down the server. Non-hot-plug devices in
the server include the processor, all boards, memory modules, fan, expansion boards, and all
system drives.
IMPORTANT: Review the specifications of a new component before installing it to make sure it is
compatible with the server. When you integrate new components into the system, record its model
and serial number, and any other pertinent information for future reference. After completing any
removal or replacement procedure, run the diagnostics program to verify that all components
operate properly.
Removal and replacement procedures 27
Download from Www.Somanuals.com. All Manuals Search And Download.
Symbols on equipment
The following symbols may be placed on equipment to indicate the presence of potentially hazardous
conditions:
This symbol indicates the presence of hazardous energy circuits or electric shock
hazards. Refer all servicing to qualified personnel.
To reduce the risk of injury from electric shock hazards, do not open this enclosure.
Refer all maintenance, upgrades, and servicing to qualified personnel.
This symbol indicates the presence of electric shock hazards. The area contains no
user or field serviceable parts. Do not open for any reason.
To reduce the risk of injury from electric shock hazards, do not open this enclosure.
This symbol on an RJ-45 receptacle indicates a network interface connection.
To reduce the risk of electric shock, fire, or damage to the equipment, do not plug
telephone or telecommunications connectors into this receptacle.
This symbol indicates the presence of a hot surface or a hot component. If this surface
is touched, the potential for injury exists.
To reduce the risk of injury from a hot component, allow the surface to cool before
touching.
This symbol indicates that the component exceeds the recommended weight for one
individual to handle safely.
99.8 kg
To reduce the risk of personal injury or damage to the equipment, observe local
occupational health and safety requirements and guidelines for manual material
handling.
220 lb
These symbols, on power supplies or systems, indicate that the equipment is supplied
by multiple sources of power.
To reduce the risk of injury from electric shock, remove all power cords to completely
disconnect power from the system.
Removal and replacement procedures 28
Download from Www.Somanuals.com. All Manuals Search And Download.
Electrostatic discharge information
An electrostatic discharge (ESD) can damage static-sensitive devices or microcircuitry. Proper
packaging and grounding techniques are necessary precautions to prevent damage. To prevent
electrostatic damage, observe the following precautions:
•
•
•
Transport products in static-safe containers such as conductive tubes, bags, or boxes.
Keep electrostatic-sensitive parts in their containers until they arrive at static-free stations.
Cover workstations with approved static-dissipating material. Use a wrist strap connected to the
work surface, and properly grounded (earthed) tools and equipment.
•
•
Keep work area free of nonconductive materials, such as ordinary plastic assembly aids and
foam packing.
Make sure that you are always properly grounded (earthed) when touching a static-sensitive
component or assembly.
•
•
•
Avoid touching pins, leads, or circuitry.
Always place drives with the Printed Circuit Board (PCB) assembly-side down.
Use conductive field service tools.
Pre-installation procedure
Perform the steps below before you open the server or before you remove or replace any component.
1.
2.
3.
Perform data backup.
Turn off the server and all the peripherals connected to it.
Unplug all cables from the power outlets to avoid exposure to high energy levels that may cause
burns when parts are short circuited by metal objects such as tools or jewelry.
If necessary, label each cable to expedite reassembly.
4.
5.
6.
Disconnect all telecommunication cables to avoid exposure to shock hazard from ringing
voltages.
Open the server according to the instructions described in the “System covers” section later in
this chapter.
Follow the ESD precautions listed previously in this chapter when handling any hardware
component.
IMPORTANT: To streamline the configuration process, read through the entire installation/removal
procedure first and make sure you understand it before you begin.
Removal and replacement procedures 29
Download from Www.Somanuals.com. All Manuals Search And Download.
Post-installation procedure
Perform the steps below after installing or removing a server component.
1.
2.
3.
Be sure all components are installed according to the described step-by-step instructions.
Check to make sure you have not left loose tools or parts inside the server.
Reinstall any expansion board, peripheral, and system cables that have previously been
removed.
CAUTION: Do not operate the server for more than ten minutes with the access panel and disk
drives removed. Otherwise, improper cooling airflow may damage the system components.
4.
5.
6.
Reinstall the system covers.
Connect all external cables and the AC power cord to the system.
Press the power button
on the front panel to turn on the server.
Powering down the server
The server does not completely power down when the power button
is pressed. The button toggles
between On and Standby. The standby position removes power from most electronics and the drives,
but some internal circuitry remains active. To completely remove all power from the system, disconnect
all power cords from the server.
WARNING: Hazardous voltages are present inside the server. Always disconnect AC power from
the server and other associated assemblies while working inside the unit. Serious injury may result if
this warning is not observed.
WARNING: To reduce the risk of electric shock or damage to the equipment:
•
•
•
•
Do not disable the power cord grounding plug. The grounding plug is an important safety feature.
Plug the power cord into a grounded (earthed) electrical outlet that is easily accessible at all times.
Unplug the power cord from the power supply to disconnect power to the equipment.
Do not route the power cord where it can be walked on or pinched by items placed against it. Pay
particular attention to the plug, electrical outlet, and the point where the cord extends from the server.
CAUTION: Protect the server from power fluctuations and temporary interruptions with a regulating
uninterruptible power supply (UPS). This device protects the hardware from damage caused by
power surges and voltage spikes, and keeps the system in operation during a power failure.
1.
2.
3.
4.
Shut down the server as directed by the operating system documentation.
Disconnect the AC power cord from the AC outlet and then from the server.
Check that the power LED indicator is turned off and that the fan noise has stopped.
Disconnect all external peripheral devices from the server.
Cable management
Always follow good cable management practices when working inside the computer.
•
•
Keep cables away from major heat sources like the heatsink.
Do not jam cables on top of expansion cards or memory modules. Printed circuit cards are not
designed to withstand excessive pressure.
Removal and replacement procedures 30
Download from Www.Somanuals.com. All Manuals Search And Download.
•
•
Keep cables clear of sliding or moveable parts to prevent cutting or crimping.
When folding a flat ribbon cable, never fold to a sharp crease. Sharp creases may damage the
wires.
•
•
•
•
•
Some flat ribbon cables come prefolded. Never change the folds on these cables.
Do not sharply bend any cable. A sharp bend can break the internal wires.
Never bend a SATA data cable tighter than a 30 mm (1.18 in) radius.
Never crease a SATA data cable.
Do not rely on components like the drive cage, power supply, or system cover to push cables
down into the chassis.
To disconnect a power supply cable from the system board:
CAUTION: Always pull the connector. NEVER pull on the cable. Pulling on the cable can damage
the cable and result in a failed power supply.
1.
2.
Squeeze on the top of the retaining latch attached to the cable end of the connector.
Grasp the cable end of the connector and pull it straight up.
Removal and replacement procedures 31
Download from Www.Somanuals.com. All Manuals Search And Download.
System cover
Panel door
The main chassis area is protected by the front panel door. This door must be opened to access the
internal components and the system board cable connections of the system drives.
To open the door:
1.
2.
Using the HP ProLiant MicroServer key to unlock the panel door.
Open the panel door of the server. If necessary, remove any components or cables that prevent
access to the slot.
Removal and replacement procedures 32
Download from Www.Somanuals.com. All Manuals Search And Download.
Top panel
The ODD is shielded by the top cover. This cover must be removed when configuring the ODD and
connecting the HDD cables with the PSU cables.
To remove the top panel:
1.
2.
Use the HP ProLiant MicroServer key to unlock the panel door.
Open the panel door of the server. If necessary, remove any components or cables that prevent
access to the slot.
3.
4.
Loosen the rear thumbscrew which locks the panel on the chassis.
Slide the top panel forward, and then lift to remove it from the chassis.
5.
Place the top cover in a safe place for reinstallation later.
Removal and replacement procedures 33
Download from Www.Somanuals.com. All Manuals Search And Download.
Drive bay configuration
The server supports four drive bays—four drive bays for 3.5-inch non-hot-plug SATA hard disk drives
(HDD).
NOTE: The server does not support hot-plug hard disk drives.
server model for the latest information on supported system drives.
IMPORTANT: When installing the hard drives, should install them from hard drive 1, then hard drive
2, hard drive 3 and hard drive 4.
Item
1
Description
Hard disk drive 1
Hard disk drive 2
Hard disk drive 3
Hard disk drive 4
2
3
4
System drive cable management
The figures in this section illustrate the system drives' data and power cable connections.
Removal and replacement procedures 34
Download from Www.Somanuals.com. All Manuals Search And Download.
SATA SKU data cable management
NOTE: Make sure the lock side of the Mini-SAS cable faces the battery when installing the Mini-SAS
cable.
Item
Description
HP spare PN
1
Mini-SAS cable
624881-001
Power cable management
Item
1
PSU cable label
Connects to
Option drive
1 hard drive
2 hard drive
P6
P2
P3
2
3
Removal and replacement procedures 35
Download from Www.Somanuals.com. All Manuals Search And Download.
Item
4
PSU cable label
Connects to
P4
P5
P1
3 hard drive
5
4 hard drive
6
24-pin power connector
Hard disk drive
Hard drives installed in the server are labeled as HDD1, HDD 2, HDD 3, and HDD 4 from left to
right, when viewed from the front of the server.
The drive bays can accommodate large form factor (LFF) non-hot-plug SATA hard drives.
Guidelines for installing hard drives
•
Install only hard drive models specified for your HP ProLiant MicroServer. Installing unsupported
hard drives may damage the system by consuming power and generating heat in excess of the
server’s operating tolerance. This condition may result in a loss of system and/or data integrity.
•
If you removed the HDD without plans of installing a new one, you must reinstall the carrier in
the chassis for proper cooling of the system.
To install a hard drive:
1.
Power off the server.
2.
3.
Open the panel door.
Remove the drive:
a. Press the drive carrier button to release the handle.
b. Extend the ejector lever.
c. Use the ejector lever to pull the drive out of the cage.
Make sure to support the drive when pulling it out of the cage.
4.
Remove the drive from the carrier:
a. Remove the screws securing the drive module.
Removal and replacement procedures 36
Download from Www.Somanuals.com. All Manuals Search And Download.
Use these screws to install the new drive.
b. Remove the drive from the carrier.
5.
Install the drive in the drive carrier:
a. Align the hard drive inside the carrier.
b. Use the screws removed in step 4a to secure the drive in the carrier.
6.
Install the drive in the drive bay:
a. Slide drive assembly into the drive bay.
b. Close the ejector lever to secure the drive.
Removal and replacement procedures 37
Download from Www.Somanuals.com. All Manuals Search And Download.
7.
Perform the post-installation procedure.
Optical disc drive
The following SATA ODD models are supported:
DVD drive
DVD-RW drive
•
•
To install an optical disc drive:
1.
Using the HP ProLiant MicroServer key to unlock the panel door.
2.
Open the panel door of the server. If necessary, remove any components or cables that prevent
access to the slot.
3.
4.
5.
Loosen the rear thumbscrew which locks the panel on the chassis.
Slide the top panel forward, and then lift to remove it from the chassis.
Remove the plastic faceplate from the top panel. Store it for future use.
Removal and replacement procedures 38
Download from Www.Somanuals.com. All Manuals Search And Download.
6.
Use a screwdriver to toggle the metal faceplate off the top panel. The metal faceplate is no
longer needed when a device is installed in the removable media drive bay.
7.
Install the optical drive:
a.Remove four spare optical drive screws from the rear side of the panel door.
b. Install the screws onto the drive.
c. Slide the drive into the media drive bay until it clicks into place.
Removal and replacement procedures 39
Download from Www.Somanuals.com. All Manuals Search And Download.
8.
Connect the optical drive cables:
a. Connect the data cable to the optical drive, and then connect the end to the system board
(J24).
b. Connect the power cable to the optical drive, and then connect the other end to the power
supply unit’s optical drive connector (P6).
9.
Slide the top panel back onto the chassis.
10. Tighten the rear thumbscrew to lock the top panel in place.
11. Close the panel door of the server.
12. Use the HP ProLiant MicroServer key to lock the panel door.
Removal and replacement procedures 40
Download from Www.Somanuals.com. All Manuals Search And Download.
Removal and replacement procedures 41
Download from Www.Somanuals.com. All Manuals Search And Download.
System board configuration
Refer to the following sections for instructions about how to remove or replace the processor, the
memory modules, the expansion cards, and the system battery. Procedure for installing the HP
MicroServer Remote Access Card option is also provided.
Remove the system board
If PCI card is installed then follow below two steps to release the PCI card, if not, go to step 1:
•
•
Rotate the PCI holder as described in below figure to release the PCI bracket.
Check the bracket to ensure there are no screws secured before removing the tray.
1.
2.
Use the HP ProLiant MicroServer Key to unlock the panel door.
Open the panel door of the server. If necessary, remove any components or cables that prevent
access to the slot.
3.
Unlock the cable clamp as shown in step 3.
Removal and replacement procedures 42
Download from Www.Somanuals.com. All Manuals Search And Download.
4.
5.
6.
Pull the power cable and fan cable out.
Unlock the cable clamp as shown in step 5.
Pull the bundle of cables out.
7.
8.
Loosen the thumbscrews on both sides of the system tray.
Pull out the system tray.
9.
Pull the system tray out until it stops on its own. An arrow sticker should be visible on the side of
the system tray.
10. Disconnect the power cable on the system board.
11. Disconnect the USB cable, fan cable, Mini-SAS cable and LED cable on the system board.
CAUTION: Avoid pinching the cables when sliding the system board tray into the chassis.
Removal and replacement procedures 43
Download from Www.Somanuals.com. All Manuals Search And Download.
IMPORTANT: Need completely remove the system tray from the chassis before attempting to remove
or replace any component on the system board.
12. Remove the four screws that secure the system board to the tray
13. Slide the system board and lift it to release the board away from the tray.
Install the system board
1.
2.
Slide the system board backward on the tray.
Fasten the four screws to secure the board on the tray.
Removal and replacement procedures 44
Download from Www.Somanuals.com. All Manuals Search And Download.
3.
4.
5.
Connect the Mini-SAS cable, LED cable and two USB cables to connectors on system board.
Connect the power cable and fan cable to connectors on system board.
Completely push the system tray into the server.
6.
Place the power cable under the tray handle in the server. Put the power cable and fan cable
together inside the left cable clamp of the chassis.
7.
8.
9.
Lock the cable clamp to secure the power cable and fan cable.
Place the LED cable and two USB cables in the server.
Secure the cables using the cable clamp on the right side of the chassis.
10. Tighten the two thumbscrews on both sides of the system tray.
Removal and replacement procedures 45
Download from Www.Somanuals.com. All Manuals Search And Download.
11. Rotate and snap in the PCI holder on the back of the chassis.
12. Make sure that all components are installed according to the described step-by-step instructions
13. Verify that you have not left tools or loose parts inside the server.
NOTE: Always carefully release the cables from the factory install cable clip before disconnecting all
cables on the system board and re-insert cables into the factory install cable clip after reinstalling all
cables.
14. Connect all external cables and the AC power cord to the system.
15. Close the panel door of the server.
16. Use the HP ProLiant MicroServer key to lock the panel door.
Removal and replacement procedures 46
Download from Www.Somanuals.com. All Manuals Search And Download.
Memory
The system has two DIMM slots that support up to 8 GB maximum system memory (4 GB in each of
the two DIMM slots).
Memory configuration
Memory installation guidelines
Observe the following important guidelines when installing memory modules:
•
Use only HP supported unbuffered ECC DDRIII DIMM in 1 GB, 2 GB or 4 GB capacities (Up to
800 MHz).
•
•
All DIMMs installed must be of the same speed.
DIMMs can be damaged by improper handling. Always use an anti-static wrist strap and
grounding mat, and discharge static electricity before touching DIMMs.
Removal and replacement procedures 48
Download from Www.Somanuals.com. All Manuals Search And Download.
To remove a memory module:
1.
Remove any accessory boards or cables that prevent access to the DIMM slots.
Remove the memory module.
2.
3.
To install a memory module:
1.
Locate an empty DIMM slot on the system board.
If necessary, open the holding clips of the selected DIMM slot.
Remove the memory module from its protective packaging, handling it by the edges.
Install the memory module.
2.
3.
4.
a. Open the DIMM slot latches.
b. Align the notch on the bottom edge of the memory module with the keyed surface of the
DIMM slot, and then fully press the memory module into the slot until the latches snap back
into place.
The DIMM slots are structured to ensure proper installation. If you insert a memory module but
it does not fit easily into the slot, you may have inserted it incorrectly. Reverse the orientation
of the module and insert it again.
Removal and replacement procedures 49
Download from Www.Somanuals.com. All Manuals Search And Download.
5.
Perform the post-installation procedure.
Removal and replacement procedures 50
Download from Www.Somanuals.com. All Manuals Search And Download.
Expansion board
System board PCI expansion slots
There are two PCI Express expansion slots on the system board.
Slot code
Slot type
Interconnect Function
x1 Supports a low-profile PCIe x1 expansion
Expansion slot
PCI Express x1
and s4
board
PCI Express x16 x16
Supports a low-profile PCIe x16 graphic
controller (25 W, max)
Removal and replacement procedures 51
Download from Www.Somanuals.com. All Manuals Search And Download.
HP ProLiant MicroServer Remote Access Card
This document provides instructions for installing the Remote Access Card in your HP ProLiant
MicroServer. This option allows users to perform server access tasks remotely over a LAN or the
Internet. The connector is shown in the figure below.
Installation guidelines
The procedures in this document are intended for individuals who are qualified in the servicing of
computer equipment and trained in recognizing hazards in products with hazardous energy levels.
WARNING: Failure to properly turn off the server before you open the server or before you start
removing or installing hardware components may cause serious damage as well as bodily harm.
WARNING: To reduce the risk of personal injury from hot surfaces, allow the chassis and any
installed hardware component to cool before touching them.
CAUTION: Observe ESD safety precautions when handling any hardware component.
IMPORTANT: Observe the pre-installation procedure before installing the IPMI card.
To install the Remote Access Card:
1.
2.
Follow the steps of removing the system tray out of the chassis.
Lift the Remote Access Card to release it from the connector (1).
Removal and replacement procedures 52
Download from Www.Somanuals.com. All Manuals Search And Download.
3.
4.
Put the card into an anti-statistic bag.
Install a new Remote Access Card:
a. Align the card with the system PCIe slot
b. Press the card down to ensure the full connection with the board.
5.
Follow the steps of installing the system tray.
Removal and replacement procedures 53
Download from Www.Somanuals.com. All Manuals Search And Download.
System battery
The server uses a nonvolatile memory that requires a battery to retain system information when power
is removed. This 3-volt 230-mAh lithium coin cell battery is located on the system board.
If the server no longer automatically displays the correct date and time, the system battery that
provides power to the real-time clock may need to be replaced. Under normal use, battery life is 5 to
10 years.
System battery replacement warnings
Observe the following reminders when replacing the system battery:
•
Replace the battery with the same type as the battery recommended by HP. Use of another
battery may present a risk of fire or explosion.
•
A risk of fire and chemical burn exists if the battery is not handled properly. Do not disassemble,
crush, puncture, or short external contacts, or expose the battery to temperatures higher than
60°C (140°F).
•
•
Do not dispose of used battery in water or fire. Dispose of used batteries according to
manufacturer's instructions.
Loss of BIOS settings occurs when the battery is removed. BIOS settings must be reconfigured
whenever the battery is replaced.
To replace the system battery:
1.
4.
2.
3.
4.
5.
Perform the pre-installation procedure.
Locate the system battery.
Push the metal clamp that extends above the top part of the battery (1).
Remove the old battery (2).
Insert the new battery into the socket, and then push it down until the clamp snaps over it (3).
IMPORTANT: If the battery socket you got is not as described as the one in the following figure, be
sure the positive side of the battery is facing the outside of the socket.
Removal and replacement procedures 54
Download from Www.Somanuals.com. All Manuals Search And Download.
6.
Perform the post-installation procedure.
System fan
The server has one system fan located on the chassis back panel wall.
A new system fan can be installed to allow the server to operate properly in case the default system
fan becomes defective.
To replace the system fan:
1.
2.
Perform the pre-installation procedure.
Remove the defective system fan:
a. Disconnect the fan cable from its system board connector (1).
b. Remove the four screws on the rear panel (2)
c. Grasp the fan by the two handles, and lift it up from the chassis (3).
Removal and replacement procedures 55
Download from Www.Somanuals.com. All Manuals Search And Download.
3.
4.
Remove the system fan from its protective packaging.
Install the new system fan:
a. Route the fan cable through the vacated fan bracket.
b. Insert the fan in the fan bracket (1).
c. Fasten the four screws (2).
d. Connect the fan cable to its corresponding board connector (3).
5.
Perform the post-installation procedure.
Power supply unit
The server uses a standard PSU with PFC (power factor correction) function.
Removal and replacement procedures 56
Download from Www.Somanuals.com. All Manuals Search And Download.
Installing the power supply unit
The system supports Server Standard & Compliant supplies, along with any other compatible supplies
that may be developed.
Power supply unit installation guidelines
Installation instructions for the MicroServer standard multi-outputs power supply. To simplify the
standard power supply unit installation, the user must remove and re-install the ODD.
1.
2.
Use the HP ProLiant MicroServer key to unlock the panel door.
Open the panel door of the server and remove any components or cables that prevent access to
the slot.
3.
4.
Loosen the rear thumbscrew which locks the top panel on the chassis.
Slide the top panel forward and then lift to remove it from the chassis.
Removal and replacement procedures 57
Download from Www.Somanuals.com. All Manuals Search And Download.
5.
Disconnect the power cables:
a. Disconnect the SATA ODD power cable and ODD cable.
IMPORTANT: Slide the ODD out of chassis before disconnecting the four hard drive power
cables
b. Disconnect the four hard drive power cables.
IMPORTANT: Pull out the system tray by following the procedure steps described in the
c. Disconnect the power cable from the system tray.
6.
Remove the standard power supply unit out of the chassis:
a. Unfasten the three screws on the back of chassis to release the power supply unit.
b. Pull the standard power supply unit out of the chassis.
Removal and replacement procedures 58
Download from Www.Somanuals.com. All Manuals Search And Download.
7.
Install the replacement power supply unit in the chassis:
reference figure on proper PSU cable connections.
8.
Connect the power cables:
a. Connect the power cable P1 to the 24-pin power connector on the system board (J12).
b. Connect the power cable P2, P3, P4 and P5 to hard drives 1, 2, 3 and 4 respectively.
c. Connect the power cable P6 to the ODD and connect the ODD cable.
d. Fasten the three screws on the back of chassis to secure the power supply unit (see the picture
above).
9.
After installing the power supply and connecting the power cables, slide the top panel to reinstall
it into the chassis.
10. Fasten the rear thumbscrew to secure the top panel on the chassis.
11. Close the front panel door of the server.
12. Use the HP ProLiant MicroServer key to lock the panel door.
Removal and replacement procedures 59
Download from Www.Somanuals.com. All Manuals Search And Download.
Item
1
PSU cable label
Connects to
P1
P2
P3
P4
P5
P6
24-pin power connector on the system board(J12)
2
Hard drive1
Hard drive2
Hard drive3
Hard drive4
Option drive
3
4
5
6
Removal and replacement procedures 60
Download from Www.Somanuals.com. All Manuals Search And Download.
Diagnostic tools
User Diagnostics
User Diagnostics is a proactive server management tool, available in HP website
administrators who verify server installations, troubleshoot problems, and perform repair validation.
User Diagnostics performs various in-depth system and component testing while the OS is not running.
IPMI Event Log
The IPMI Event Log is a log that is generated by the management controller when it detects significant
or critical system management events. This includes messages for events such as ‘temperature
threshold exceeded’, ‘voltage threshold exceeded’, ‘power fault’, etc.
To view the IPMI event log:
1.
Turn on the monitor and the server.
If the server is already turned on, save your data and exit all open applications, and then restart
the server.
2.
3.
4.
During POST, press F10 to access the AMI BIOS Setup Utility.
In the Advanced menu screen, select the IPMI field, and then press Enter.
Select System Event Log, and then press Enter.
For more information on the IPMI Card, see the HP Microserver Remote Access Card User Manual on
Reset the MicroServer Remote Access Card password to
default
The user can use the IPMI tool with KCS to reset password. The following IPMI command illustrates
how to reset the administrator password to “password” by linux ipmitool:-
Ipmitool raw 18 47 82 2 0x70 0x61 0x73 0x73 0x77 0x6f 0x72 0x64 0x00 0x00
0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00
NOTE: The password be encrypted and storied in flash, user can not only recover the password by
update flash data. After reflashing the firmware, all data, password and configurations will be reset
to default.
The MicroServer Remote Access Card support the following character categories:
•
•
Uppercase letters: A, B, C
Lowercase letters: a, b, c
Diagnostic tools 61
Download from Www.Somanuals.com. All Manuals Search And Download.
•
•
Numbers: 0, 1, 2, 3, 4, 5, 6, 7, 8, 9
Symbol (special characters): ` ~ @ # $ % & * ( ) _ - + = { } [ ] \ | : ; “ ‘ < > , . ? /
Graceful shutdown function
1.
When system temperature reached to trip caution point or system fan failed, the system will do a
graceful shut down to protect data loss. Graceful shut down Setting Step
2.
Update the latest BIOS and load default in RBSU.
3.
4.
Install Windows 2008 R2 Edition.
Log into the Windows operating system, and install all required drivers (chipset, VGA, NIC,
iBMC).
a. Select Shut down in the OS screen saver setting.
b. In screensaver setting, click Change power setting.
Diagnostic tools 62
Download from Www.Somanuals.com. All Manuals Search And Download.
c. Click Choose what the power buttons do.
d. From the When I press the power button: drop-down menu, select Shut down, and then
click Save changes.
Diagnostic tools 63
Download from Www.Somanuals.com. All Manuals Search And Download.
When system fan fails or sensor temperature is higher than caution point, the system will gracefully
shutdown.
The system temperature sensors and their corresponding breach level are listed below:
•
•
•
Processor: 105°C
North bridge: 100°C
Ambient temperature: 40°C.
AMD RAIDXpert Utility
This utility enables RAID array management in the Microsoft Windows environment. For the utility
To install the RAIDXpert:
1.
Click the application file twice to install the RAIDXpert.
Diagnostic tools 64
Download from Www.Somanuals.com. All Manuals Search And Download.
2.
Select language and click OK to continue.
3.
Click Next.
Diagnostic tools 65
Download from Www.Somanuals.com. All Manuals Search And Download.
4.
Select I accept the terms of the license agreement and click Next.
5.
Click Browse to select folder and then click Next.
Diagnostic tools 66
Download from Www.Somanuals.com. All Manuals Search And Download.
6.
Click Next.
7.
Click Install.
Diagnostic tools 67
Download from Www.Somanuals.com. All Manuals Search And Download.
8.
Click Finish.
9.
Click the program under Start menu twice -> AMD folder.
Diagnostic tools 68
Download from Www.Somanuals.com. All Manuals Search And Download.
10. Key in default Login ID: admin, and the password:admin.
11. Select whether to remember the password.
Diagnostic tools 69
Download from Www.Somanuals.com. All Manuals Search And Download.
12. Click + in front of Physical Drive View.
13. Click options Enable or Disable to change Write cache and NCQ status.
Diagnostic tools 70
Download from Www.Somanuals.com. All Manuals Search And Download.
Diagnostic tools 71
Download from Www.Somanuals.com. All Manuals Search And Download.
AMI BIOS software
Your ProLiant MicroServer uses BIOS to boot up the system. AMI BIOS software is a ROM BIOS-based
firmware that allows reliability, manageability, and connectivity for server platforms. This software
contains a set of programs permanently stored in an EEPROM chipset located on the system board.
These programs assist in managing, initializing, and testing the hardware devices installed on the
computer.
The AMI BIOS software serves three functions:
•
•
•
Configure the system from the AMI BIOS Setup Utility
Using the Setup program, you can install, configure, and optimize the hardware devices on your
system (clock, memory, disk drives, etc.). In addition, you can enable various features such as
serial console redirection, PXE boot, and much more.
Initialize hardware at boot using POST routines
During power-on or warm reset, the software performs Power-On Self-Test (POST) routines to test
components, to allocate resource for various hardware devices, and to prepare the system to
boot to various operating systems.
Perform run-time routines
Using the software, perform basic hardware routines that can be called from DOS and Windows
applications.
Configuring the system BIOS
NOTE: For ease of reading, AMI BIOS Setup Utility will be simply referred to as “Setup” or
“Setup Utility” in this guide. Also, the screenshots used in this guide display various Setup
menu screens with the default values identified. These values may not be the same as those in
your server.
AMI BIOS Setup Utility is a hardware configuration program built into your system's Basic
Input/Output System (BIOS). Since most systems are already properly configured and optimized,
there is normally no need to run this utility.
You will need to run this utility under the following conditions:
•
When changing the system configuration including:
○ Setting the system time and date
○ Configuring the hard drives
○ Specifying the boot device sequence
○ Installing PCI expansion boards
○ Upgrading the system BIOS
○ Configuring the power management modes
○ Setting up system passwords or making other changes to the security setup
•
When a configuration error is detected by the system and you are prompted (Run Setup
message) to make changes to the BIOS settings.
NOTE: If you repeatedly receive Run Setup messages, the system battery may be defective. In
this case, the system cannot retain configuration values in CMOS. Replace the system battery
with a new one.
Diagnostic tools 72
Download from Www.Somanuals.com. All Manuals Search And Download.
The Setup Utility loads the configuration values in a battery-backed nonvolatile memory called CMOS
RAM. This memory area is not part of the system RAM, which allows configuration data to be
retained when power is turned off. The values take effect when the system is booted. POST uses these
values to configure the hardware. If the values and the actual hardware do not agree, POST
generates an error message. You must run this utility to change the BIOS settings from the default or
current configuration.
The Setup Utility has five primary menu selections, including:
•
•
•
•
•
Main
Advanced
Boot
Security
Exit
To run the Setup Utility:
1.
Turn on the monitor and the server.
If the server is already turned on, save your data and exit all open applications, and then restart
the server.
2.
During POST, press F10.
If you fail to press F10 before POST is completed, you will need to restart the server.
The first page to be displayed will be the Main menu showing the Setup Utility’s menu bar. Use
the left () and right () arrow keys to move between selections on the menu bar.
Setup Utility navigation keys
Use the following keyboard keys to work your way through the various menu and submenu screens of
the Setup Utility.
Key
Functions
← and →
↑ and ↓
To move between selections on the menu bar.
To move the cursor to the field you want.
The currently selected field will be highlighted. The right side of each menu screen
displays the Item Specific Help panel. This panel displays the help text for the currently
selected field. It updates as you move the cursor to each field.
PgUp and PgDn
Home
To move the cursor to the previous and next page of a multiple page menu.
To move the cursor to the first page of a multiple page menu.
End
To move the cursor to the last page of a multiple page menu.
(+) , (–),
To select a value for the currently selected field (only if it is user-configurable).
Press the (+), (–), or <Space> keys repeatedly to display each possible entry, or the
Enter key to choose from a pop-up menu.
A parameter that is enclosed in square brackets [ ] is user-configurable.
Grayed-out parameters are not user-configurable for one of the following reasons:
The field value is auto-configured or auto-detected.
The field value is informational only.
The field is password-protected.
Diagnostic tools 73
Download from Www.Somanuals.com. All Manuals Search And Download.
Key
Functions
Enter
Ctrl+Enter
F1
To select a field value or display more options for menu marked with ►.
To expand all device lists.
To open the General Help window.
The General Help window describes other Setup navigation keys that are not displayed
on the legend bar.
Esc
If you press this key:
On one of the primary menu screens, the Exit menu appears.
On a submenu screen, the previous screen appears.
When you are making selections from a pop-up menu, closes the pop-up without
making a selection.
F9
Loads the default system values.
F10
Saves changes and closes the Setup Utility.
Setup Utility menus
The Setup Utility provides a menu bar with the menu selections. The menu bar choices are described
in the following sections.
Diagnostic tools 74
Download from Www.Somanuals.com. All Manuals Search And Download.
Main menu
Field
Description
BIOS ID
System BIOS ID
BIOS Version
System Time
System Date
Speed
System BIOS version
Adjust the system time.
Adjust the system date.
Processor speed
Core Count
Size
Number of core in the processor
System memory size
Diagnostic tools 75
Download from Www.Somanuals.com. All Manuals Search And Download.
Field
Description
Set Server Asset Text
Enter the server asset tag. This information is printed on the serial label tab
located on the front panel.
Set Serial Number Text
Show server serial number. This information is printed on the serial label
tab located on the front panel.
Embedded NIC1 MAC Address
Boot Settings Configuration
MAC address of the embedded NIC
Configure settings during system boot
Advanced menu
Field
Description
CPU Configuration
Configure and view the current CPU Configuration and settings.
Press Enter to access the related submenu.
IDE Configuration
ACPI Configuration
Event Log Configuration
IPMI
Use this screen to select options for IDE configuration settings.
Press Enter to access the related submenu.
Use this screen to select options for the ACPI Configuration.
Press Enter to access the related submenu.
Displays the information related to the Event Log.
Press Enter to access the related submenu.
Configure the Intelligent Platform Management Interface (IPMI) settings.
Press Enter to access the related submenu.
PCI Express Configuration
USB Configuration
Use this screen to select options for PCI Express Devices.
Press Enter to access the related submenu.
Displays the settings related to the USB function.
Press Enter to access the related submenu.
Diagnostic tools 76
Download from Www.Somanuals.com. All Manuals Search And Download.
Boot menu
Use this menu to set the preferred drive sequence in which the Setup Utility attempts to boot the
operating system.
By default, the server searches for boot devices in the following order:
•
•
•
•
CD-ROM/DVD-ROM drive
Removable device
Hard drive
Embedded NIC
To implement the PXE boot option, you need to first set the Embedded NIC Port1 Control field to
Enabled.
Field
Description
Boot Device Priority
Hard Disk Drives
Specifies the Boot Device Priority sequence
Specifies the Boot Device Priority sequence from available
Control the listed USB functions by setting the item to the desired value.
Disable and enable embedded NIC1
USB Device Boot Priority
Embedded NIC Port 1 Control
Wake-On LAN
Disabled and Enable the WOL function
Diagnostic tools 77
Download from Www.Somanuals.com. All Manuals Search And Download.
Security menu
Field
Description
Admin Password
Current admin password status (Clear or Enabled)
Change Admin Password
Select the field, and then press Enter to set, change, or remove a admin
password.
Admin password
The Security menu allows users to set an admin password. When entered, this password will allow
the user to access and change all settings in the Setup Utility.
To set an admin password:
1.
2.
In the Security menu screen, select the Admin Password field then press Enter.
Type a new password in the password box.
The password may consist of up to eight alphanumeric characters (A-Z, a-z, 0-9).
Retype the password to verify the first entry, and then press Enter.
Press F10 to save the password and close the Setup Utility.
3.
4.
After setting the password, the Admin Password field value is set to Enabled.
To change the admin password:
1.
In the Security menu screen, select the Admin Password field, and then press Enter.
Type the original password in the password box.
2.
3.
4.
5.
Type a new password, and then press Enter.
Retype the new password to verify the first entry, and then press Enter again.
Press F10 to save the password and close the Setup Utility.
To remove the admin password:
1.
2.
In the Security menu screen, select the Admin Password Is field, and then press Enter.
Type the original password then press Enter.
Diagnostic tools 78
Download from Www.Somanuals.com. All Manuals Search And Download.
3.
4.
Press Enter twice without entering anything in the new and confirm password fields.
Press F10 to save the changes you made and close the Setup Utility.
The Admin Password field value is set to Clear.
To reset the admin password:
If you forget the admin password, you need to clear the CMOS and reset the BIOS settings to regain
Exit menu
Field
Description
Save Changes and Exit
Saves changes made and closes the Setup Utility.
Keyboard shortcut: F10
Discard Changes and Exit
Discard Changes
Discards changes made and closes the Setup Utility.
Discards all changes made to the Setup Utility and loads the previous
configuration settings.
Load Optional Defaults
Loads the factory-default settings for all Setup fields.
Keyboard shortcut: F9
Summary screen
The Summary screen displays basic and important information about the current server configuration
and is necessary for troubleshooting and may be required when asking for technical support. It is
recommended that you check this screen during the initial system setup and each time you install,
remove, or upgrade accessories.
To view the Summary screen:
You first need to enable the display of the Summary screen during bootup. Follow the steps below.
Diagnostic tools 79
Download from Www.Somanuals.com. All Manuals Search And Download.
1.
2.
3.
4.
5.
In the Main menu screen, select Boot Settings Configuration, and then press Enter.
Select the Quick Boot field.
Press the plus (+) or minus (–) key to set the field to Enabled.
Press F10 to save the changes you made and close the Setup Utility.
Reboot the server.
The Summary screen is displayed briefly at the end of POST.
6.
7.
Press the Pause/Break key to continue displaying the screen until another key is pressed.
Press any key to continue with the system bootup.
Power-On-Self-Test
Before you can use a server, all devices must be tested and initialized, and the operating system must
be bootstrapped to the memory. This is referred to as Power-On-Self-Test or POST. POST is a series of
diagnostic tests that checks firmware and hardware components to ensure that the server is properly
functioning. This diagnostic function automatically runs each time the server is powered on.
These diagnostics, which reside in the BIOS ROM, isolate server-related logic failures and indicate the
board or component that needs to be replaced, as indicated by the error messages. Most server
hardware failures will be accurately isolated during POST. The number of tests displayed depends on
the configuration of the server.
During POST you can press:
•
•
F10 to access the Setup Utility.
F12 to request a network boot (PXE).
POST error messages
Whenever a non-critical error occurs during POST, an error message describing the problem appears
onscreen. These text messages are displayed in normal video (white text on black background). It
shows the details of the error. The following is an example of a POST error message:
ERROR
Diagnostic tools 80
Download from Www.Somanuals.com. All Manuals Search And Download.
0251: System CMOS checksum bad – Default configuration used
In some cases an error message may include recommendations for troubleshooting or require that you
press the Enter key to display recommendations. Follow the instructions on the screen.
The next table lists the most common POST error messages with their corresponding troubleshooting
recommendation. It is recommended that you correct the error before proceeding, even if the server
appears to boot successfully.
If your system displays one of the messages marked below with an asterisk (*), write down the code
and message and contact your HP Customer Support provider.
Error code
Error message
Corrective action/description
000
Timer Error
Indicates an error while programming the
count register of channel 2 of the 8254 timer.
This might indicate an issue with system
hardware and requires repairing the system
board.
003
CMOS Battery Low
CMOS Battery is low. This message usually
indicates that the CMOS battery needs to be
replaced. It might also appear when the users
intentionally discharge the CMOS battery
004
008
CMOS Settings Wrong
Unlock Keyboard
CMOS settings are invalid. This error can be
resolved by using F9 to load optimal default
in the Setup Utility
PS2 keyboard is locked. User must unlock the
keyboard to continue the BIOS POST.
010
011
KBC BAT Test failed
The bat test on keyboard controller failed
CMOS Memory Size Wrong
The base memory (memory below 1MB) size
that is reported in the CMOS (offset 15h)
mismatches with the actual size detected. This
condition may occur when the hole is set at
512K base memory or when CMOS is
corrupted.
00C
00D
012
RAM R/W test failed
This message appears by the AMI BIOS8
when the RAM read/write test fails.
Uncorrectable Memory ECC Error! If DIMM occur Uncorrectable Memory ECC
Error!, this message will appear on POST.
CMOS Date/Time Not Set
The CMOS date and/or time are invalid. This
error can be resolved by readjusting the
system time in the Setup Utility.
015
016
Fan Missing!
If system fan is not installed or failed, the
system will display this message and
shutdown in minutes.
System board temperature out of If system detects system board temperature
range
sensor over heat, this message will appear.
Diagnostic tools 81
Download from Www.Somanuals.com. All Manuals Search And Download.
Error code
Error message
Corrective action/description
017
Processor temperature out of
range
If the system detects that the processor
temperature sensor over heated, then this
message will appear.
018
040
NB temperature out of range
Refresh timer test failed
If system detects NB temperature sensor over
heat, this message will appear.
BIOS POST found that the refresh timer
hardware failed to pass the Refresh Retrace
Test.
041
043
044
Display memory test failed
~<INS> Pressed
Memory test failed because the memory has
an issue
If you press Insert key during POST, this
message will appear
DMA Controller Error
The system found some issues of the DMA
controller when performing diagnostic tests
for DMAC-1 & DMAC-2.
045
046
048
05D
DMA-1 Error
The system found some issues of the DMA
controller when do diagnostic tests for
DMAC-1
DMA-2 Error
The system find some issues of the DMA
controller when do diagnostic tests for
DMAC-2
Password check failed
S.M.A.R.T. Command Failed
If the user inputs an incorrect password more
than three times, then this error displays
information and the system continues to boot.
Hard Disk S.M.A.R.T feature test failed,
indicating an issue with the hard disk.
POST related troubleshooting
Perform the following procedures when POST fails to run or displays error messages.
If the POST failure is during a routine boot up, check the following:
•
•
•
All external cables and power cables should be firmly plugged in.
The power outlet to which the server is connected and is working.
The server and monitor are both turned on. The power status LED indicator on the front panel
must be lit up green.
•
•
•
•
•
The monitor's contrast and brightness settings are correct.
All internal cables are properly connected and all boards are firmly seated.
The processor is fully seated in its socket.
The heatsink is properly installed on top of the processor.
All memory modules are properly installed.
Diagnostic tools 82
Download from Www.Somanuals.com. All Manuals Search And Download.
•
If you have installed a PCI expansion board, verify that the board is firmly seated and any
switches or jumpers on the board are properly set. See the documentation that came with the
expansion board.
•
•
All system cables are securely connected and are in their proper order.
If you have changed any switches on the system board, verify that each is properly set.
Diagnostic tools 83
Download from Www.Somanuals.com. All Manuals Search And Download.
Item
3
Description
PCIe holder
4a
4b
5
PCIe bracket 1
PCIe bracket 2
eSATA connector
Rear USB 2.0 ports
VGA port
6
7
8
Embedded NIC Port
Rear system fan
Kensington lock slot
9
10
Connectors, switches, and LEDs 86
Download from Www.Somanuals.com. All Manuals Search And Download.
System board
Item
1
Designator
J16
J15
J23
J6
Description
VGA connector
2
NIC1/USBx2 connector
3
eSATA
4
PCIe x1 slot
5
J21
J5
NMI jumper. Enables a user to generate a nonmaskable interrupt event.
PCIe x16 slot
6
7
J7
IPMI slot
8
J24
J8
Internal SATA for ODD option
Mini-SAS connector
9
10
11
12
13
14
15
16
J33
B1
Internal USB connector for tape drive option
Battery
J22
J20
J13
J14
J50
Fan connector
TPM connector
Front USB header 1
Front USB header 2
Front LED cable connector
Clear CMOS jumper;1-2, Normal
Clear CMOS jumper; 2-3, Clear CMOS
24-pin power connector (ATXPWRCN)
Processor
17
17
J19
J19
18
19
J12
U1
Connectors, switches, and LEDs 87
Download from Www.Somanuals.com. All Manuals Search And Download.
Item
20
Designator
Description
J3
J4
DDR 3 DIMM slot 1
DDR 3 DIMM slot 2
21
System buttons and jumpers
System jumpers
Item
Function
Status
Open
Short
Status description
1
NMI jumper
Normal
Enables a user to generate a
nonmaskable interrupt event.
2
Clear CMOS jumper
1-2
2-3
Normal
Clear CMOS
Connectors, switches, and LEDs 88
Download from Www.Somanuals.com. All Manuals Search And Download.
System specifications
Hardware specifications
System unit
Item
Description
Processor
1.3-GHz AMD Athlon II Neo N36L processor, 2C
1.5-GHz AMD Turion II Neo N40L processor, 2C
2.2-GHz AMD Turion II Neo N54L processor, 2C
Core logic chipsets
•
•
•
AMD RS785E – north bridge, core logic controller
AMD SB820M– south bridge
AST2150 (option) – BMC controller
Hardware monitoring
chipset
Winbond W83795ADG hard monitor chip
LAN controller
Broadcom BCM5723 single-port Gigabit Ethernet controller
Integrated in the processor
Memory controller
SATA storage controller
VGA controller
Embedded AMD SB820M chipset
Integrated in the AMD RS785E chipset
I/O subsystem
•
•
•
One PCIe x16 slot, which supports one PCIe x16 card (25 W, max)
One PCIe x1 slot, which supports one PCIe x1 card
One PCIe x4 slot, which supports one IPMI card
Memory
•
•
•
ECC UDIMM
Two DDR 3 slots
8 GB maximum system memory (4 GB in each of the two DIMM slots)
Media storage
I/O ports
•
•
Four LFF HDD bays support non-hot-plug SATA drives
Removable media drive bay supports installation of an optical drive, tape drive,
or RDX drive options
•
•
Front panel – Four USB 2.0 Ports
Rear panel – Two USB 2.0 Ports, one rear VGA port (RS785E embedded, D-
SUB15), one Gigabit Ethernet RJ-45 port, one eSATA port
•
•
Internal – One SATA port, one internal USB port
Status LED indicators
Server management
Front panel – Power LED, HDD LED, LAN LED, Health LED
•
•
•
Dedicated system health indicator
Onboard hardware failure indicators
Management NIC function via the HP MicroServer Remote Access Card
(optional)
System specifications 90
Download from Www.Somanuals.com. All Manuals Search And Download.
Item
Description
Thermal solution
•
•
•
•
One system fan
Processor heatsink
North bridge heatsink
South bridge heatsink
Memory
Item
Description
Number of DIMM slots
Two
Maximum memory
capacity
8 GB (4 GB in each of the two DIMM slots)
Memory modes
Memory controller
DIMM specifications
Size
Single DIMM, and two DIMMs (full configuration)
Integrated in the processor
1 GB, 2 GB, and 4 GB
800 MHz
Speed
Type
DDR3, UDIMM,1333 MHz ECC RoHS
Power supply unit
150 W power supply
Item
Description
DPS -150TB A
150 W
Model
Type
Dimensions
Height
40.5 mm (1.59 in)
150.0 mm (5.9 in)
81.5 mm (3.21 in)
Depth
Width
Weight (approximate)
0.7kg (1.54lb)
Input requirements
Rated input voltage
Normal line voltage
90 to 264 VAC
100 VAC to127 VAC/200 VAC to 240 VAC
Line frequency
47 to 63 Hz
Rated input current
Ready steady state power
3.5 A rms max @ 100 VAC full load; 2 A rms max @ 200 VAC full load
150 W
System specifications 91
Download from Www.Somanuals.com. All Manuals Search And Download.
Item
Description
Operating conditions
Temperature
0 to 50°C (0 to 122°F)
Humidity (noncondensing)
20 to 90%
200 W power supply
Item
Description
DPS-200PB-177A
200 W
Model
Type
Dimensions
Height
40.5 mm (1.59 in)
150.0 mm (5.9 in)
81.5 mm (3.21 in)
Depth
Width
Weight (approximate)
0.7 kg (1.54 lb)
Input requirements
Rated input voltage
Normal line voltage
90 to 264 VAC
100 to 240 VAC
Line frequency
47to 63 Hz
Rated input current
Rated steady state power
200 W @ 3.5A max
200 W
Operating conditions
Temperature
0 to 50°C
Humidity (noncondensing)
20 to 85%
System specifications 92
Download from Www.Somanuals.com. All Manuals Search And Download.
Physical specifications
Item
Description
System board dimensions
Length
Width
211.0 mm (8.3 in)
165.1 mm (6.5 in)
Server dimensions
Height
267 mm (10.51 in)
245 mm (9.65 in)
210 mm (8.27 in)
Width
Depth
Server weight (maximum
configuration, approximate)
Basic configuration (one hard
drive installed)
8.6 kg (18.96 lb)
10 kg (22.04 lb)
Fully loaded configuration
System specifications 93
Download from Www.Somanuals.com. All Manuals Search And Download.
Environmental specifications
Item
Attribute
Temperature range
Operating
10 to 35°C (50 to 95°F)
-30 to 60°C (-22 to140°F)
Nonoperating
Humidity (noncondensing)
Operating
10 to 90% RH
10 to 95% RH
Nonoperating
Altitude
Operating
Nonoperating
3048 m (10,000 ft)
9144 m (30,000 ft)
Acoustic noise
Idle, minimum (fixed disk drives L Wad (BELS) – 3.8
spinning)
L pA (dBA) – 21.4
Operating, minimum (random
seeks to fixed disk drives)
L Wad (BELS) – 3.9
L pA (dBA) – 22.7
System specifications 94
Download from Www.Somanuals.com. All Manuals Search And Download.
Index
A
D
AC power
diagnostics
power-down procedure, 30
AMI BIOS Setup Utility, 72
Advanced menu, 76
Boot menu, 77
AMI BIOS software, 72
HP Insight Diagnostics, 61
IPMI Event Log, 61
drive bay configuration
data cable management, 34
hard drives, 36
CMOS RAM, 73
Exit menu, 79
General Help window, 74
Item Specific Help panel, 73
legend bar, 73
optical disc drive, 38
power cable connections, 35
E
Main menu, 75
electrostatic discharge, 29
environmental specifications
acoustic noise, 94
altitude, 94
non-user-configurable field, 73
overview, 72
running, 73
Security menu, 78
supervisor password, 78
user-configurable field, 73
AMI BIOS software
POST, 80
relative humidity, 94
temperature, 94
ESD
precautions, 29
work area recommendations, 29
expansion board
B
Basic Input/Output System, 72
battery
system board expansion slots, 51
H
location, 54
hard drive
replacement warnings, 54
replacing, 54
configuring, 76
installation guidelines, 36
installing, 36
boot sequence
configuring, 77
default settings, 77
boot-time diagnostic screen
viewing, 79
removing, 36
hardware configuration
Proliant MicroServer Remote Access Card, 52
hardware configuration
expansion board, 51
memory, 48
C
cable management, 30
CMOS RAM
opening the server, 32
post-installation procedure, 30
pre-installation procedure, 29
symbols in equipment, 28
system drives, 34
resetting, 80
core logic chipset
north bridge, 90
south bridge, 90
CSR, 5
tools, 26
customer self repair, 5
warnings/precautions, 26
Index 95
Download from Www.Somanuals.com. All Manuals Search And Download.
hardware configuration
system battery, 54
POST
error messages, 80
hardware configuration
system fans, 55
overview, 80
running, 80
hardware configuration
power supply unit, 56
hardware configuration
AMI BIOS Setup Utility, 72
hardware configuration
boot-time diagnostic screen, 79
HP
troubleshooting, 82
power fluctuations, caution, 30
power supply unit
replacement warnings, 57
Power-On Self-Test, 80
primary access panel
removing, 32
contact information, 25
technical support, 25
processor
configuring, 76
I
PSU
I/O ports
listing, 90
rear panel, 85
specifications, 91
S
I/O subsystem, 90
illustrated parts catalog
SAS hard drive
installing, 36
system components, 21
installation guidelines
hard drive, 36
SATA hard drive
installing, 36
secondary access panel
removing, 33
server management
configuring, 76
specification, 90
status LED indicators, 89
spare parts
IPMI Event Log
viewing, 61
M
MAC address, 76
Media Access Control, 76
memory
storing, 29
transporting, 29
supervisor password
changing, 78
removing, 78
resetting, 79
installation guidelines, 48
installing, 49
memory size value, 75
multi-boot support, 77
O
setting, 78
onboard controllers
LAN, 90
system BIOS
overview, 72
memory controller, 90
storage controller, 90
VGA, 90
system board
dimensions, 93
system components
front panel, 84
panel door, 85
rear panel, 85
system board, 87
system fan
P
panel door, 85
physical specifications
server, 93
system board, 93
Index 96
Download from Www.Somanuals.com. All Manuals Search And Download.
cable connections, 55
system fans
environmental, 94
hardware, 90
installing, 56
memory, 91
removing, 55
system jumpers, 88
system time
physical, 93
power supply unit, 91
thermal solution, 91
setting, 75
W
T
warranty, 5
technical specifications
Index 97
Download from Www.Somanuals.com. All Manuals Search And Download.
|
Graco Inc Paint Sprayer 1030 FC User Manual
Greenheck Fan Ventilation Hood FSD 311V User Manual
Haier Freezer 405SD User Manual
Harbor Freight Tools Cordless Drill 91176 User Manual
Hotpoint Dishwasher 7840 User Manual
Husky Plumbing Product GAEA2418 User Manual
Husqvarna Chainsaw 324LDX Series User Manual
IBM Computer Drive 10K3791 User Manual
iHome Portable Speaker IHM16 User Manual
IKEA Plumbing Product AA 322687 2 User Manual