HP Smart Array P800 Controller
for HP ProLiant Servers
User Guide
Part Number 432600-002
August 2007 (Second Edition)
Download from Www.Somanuals.com. All Manuals Search And Download.
Contents
Hardware features........................................................................................................................ 5
Controller specifications............................................................................................................................. 5
Installing the controller in a previously-configured server................................................................................. 7
Installing the controller hardware.................................................................................................... 9
Connecting storage devices...................................................................................................................... 10
Connecting internal storage............................................................................................................ 10
SAS cable part numbers................................................................................................................. 11
Methods for updating the firmware............................................................................................................ 12
Utilities available for configuring an array.................................................................................................. 13
Setting the boot controller and controller order............................................................................... 14
Installing device drivers............................................................................................................................ 16
Replacing, moving, or adding hard drives..................................................................................... 25
Recognizing hard drive failure.................................................................................................................. 26
Replacing hard drives.............................................................................................................................. 28
Automatic data recovery (rebuild).................................................................................................... 29
Adding drives......................................................................................................................................... 32
Contents
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Electrostatic discharge................................................................................................................. 37
Preventing electrostatic discharge.............................................................................................................. 37
Grounding methods to prevent electrostatic discharge.................................................................................. 37
Cables................................................................................................................................................... 38
BSMI notice............................................................................................................................................ 39
Contents
4
Download from Www.Somanuals.com. All Manuals Search And Download.
Hardware features
Main components on the board
Item ID
Description
1
2
Connector for SAS miniports 1E and 2E (external), each 4x wide
Heartbeat LED (flashes green when operating normally and amber
if the board has failed)
3
4
5
6
7
Activity LED for external ports
SAS port 3I (internal), 4x wide
SAS port 4I (internal), 4x wide
Cache module (also known as BBWC or array accelerator)
Batteries for cache module (Two batteries are normally sufficient,
but a third can be added to provide extra security against loss of
system power.)
Controller specifications
Feature
Details
Card type
Full-size PCIe
Dimensions (excluding bracket)
Type of drives supported
Maximum power required
31.1 cm × 11.1 cm × 1.2 cm (12.3 in × 4.4 in × 0.5 in)
3 Gb/s SAS or 1.5 Gb/s SATA
Approximately 25 W
Hardware features
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Temperature range
Operating, 10° to 55°C (50° to 131°F)
Storage, -30° to 60°C (-22° to 140°F)
Relative humidity
(noncondensing)
Operating, 10% to 90%
Storage, 5% to 90%
RAID levels supported
Type of edge connector
PCIe transfer rate
0, 1, 1+0, and 5; also 6 if the batteries are used
PCIe x8
Up to 2 GB/s in each direction
Number of SAS ports
Two internal, two external; each port has four 1x links
Maximum number of physical
drives (using all four ports)
108 (8 can be connected internally, and a further 100 can be
connected externally by using expanders)
Maximum number of logical
drives
32
Maximum size of a logical drive More than 2 TB
SAS transfer rate
Up to 1.2 GB/s per port in each direction
Spare battery part number
398648-001
Time required to recharge
battery
From 15 minutes to 2 hours, depending on the initial battery charge
level
Duration of battery backup
More than 2 days if the batteries are fully charged and less than 3
years old
Battery life expectancy
Cache size
More than 3 years
512 MB (48 MB is used by the onboard processor)
For more information about the controller features and specifications, and for information about system
Hardware features
6
Download from Www.Somanuals.com. All Manuals Search And Download.
Overview of the installation procedure
Installing the controller in an unconfigured server
New HP ProLiant server models autoconfigure when they are powered up for the first time. For more
information about the autoconfiguration process, see the server-specific setup and installation guide or the
HP ROM-Based Setup Utility User Guide. These guides are available on the server Documentation CD.
IMPORTANT: Do not power up the server until the hardware configuration is satisfactory, as
described in the procedure given in this section.
To install the controller in an unconfigured server:
1.
2.
If necessary, install physical drives.
The number of drives connected to the controller determines the RAID level that is autoconfigured
when the server is powered up. For details, see the server-specific setup and installation guide or the
HP ROM-Based Setup Utility User Guide.
3.
4.
5.
6.
Power up the server. The autoconfiguration process runs.
Install the operating system and device drivers ("Installing device drivers" on page 16). Instructions
are provided with the CD that is supplied in the controller kit.
7.
The server is now ready to use.
Installing the controller in a previously-configured
server
1.
2.
3.
Back up data on the system.
If the new controller will be the boot device, install the device drivers ("Installing device drivers" on
4.
5.
6.
7.
8.
9.
Power down the server.
Power down peripheral devices.
Unplug the AC power cord from the server.
Disconnect peripheral devices.
Overview of the installation procedure
7
Download from Www.Somanuals.com. All Manuals Search And Download.
10. Reconnect peripheral devices and the AC power supply to the server.
11. Power up peripheral devices.
12. Power up the server.
14. (Optional) Set this controller as the boot controller using ORCA ("Setting a controller as the boot
15. (Optional) Change the controller boot order using RBSU ("Setting the controller order" on page 14).
16. If the controller will not be the boot device, install the device drivers ("Installing device drivers" on
17. If new versions of the Management Agents are available, update the Management Agents
The server is now ready to use.
Overview of the installation procedure
8
Download from Www.Somanuals.com. All Manuals Search And Download.
Installing the controller hardware
Preparing the server
1.
2.
3.
Back up all data.
Close all applications.
Power down the server.
CAUTION: In systems that use external data storage, be sure that the server is the first unit to
be powered down and the last to be powered back up. Taking this precaution ensures that the
system does not erroneously mark the drives as failed when the server is powered up.
4.
5.
6.
Power down all peripheral devices that are attached to the server.
Unplug the AC power cord from the outlet and then from the server.
Disconnect all peripheral devices from the server.
Installing the controller board
WARNING: To reduce the risk of personal injury or damage to the equipment, consult the
safety information and user documentation provided with the server before attempting the
installation.
Many servers are capable of providing energy levels that are considered hazardous and are
intended to be serviced only by qualified personnel who have been trained to deal with these
hazards. Do not remove enclosures or attempt to bypass any interlocks that may be provided
for the purpose of removing these hazardous conditions.
1.
Remove or open the access panel.
WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the
internal system components to cool before touching them.
2.
3.
4.
Select an available x8 or larger PCIe slot.
Remove the slot cover. Save the retaining screw, if one is present.
Slide the controller board along the slot alignment guide, if one is present, and press the board
firmly into the slot so that the contacts on the board edge are properly seated in the system board
connector.
5.
6.
7.
Secure the controller board in place with the retaining screw. If the slot alignment guide has a latch
(near the rear of the board), close the latch.
Connect storage devices to the controller. (For details of the procedure, see "Connecting storage
Close or replace the access panel, and secure it with thumbscrews, if any are present.
Installing the controller hardware
9
Download from Www.Somanuals.com. All Manuals Search And Download.
CAUTION: Do not operate the server for long periods with the access panel open or removed.
Operating the server in this manner results in improper airflow and improper cooling that can
lead to thermal damage.
Connecting storage devices
You can connect SAS or SATA drives to the controller internally ("Connecting internal storage" on page
For information about supported drive models, see the controller-specific page on the HP website
Connecting internal storage
1.
2.
Power down the server.
Install hard drives, if necessary. If you want to group some of the drives in an array, they must meet
the following criteria:
o
They must be of the same type, either all SAS or all SATA. (This controller does not support
parallel SCSI drives.)
o
For efficient use of drive space, they must have comparable capacity.
For additional information about drive installation, see the appropriate section in this guide
the documentation that accompanied the drives.
3.
Use the internal wide SAS cable provided with the server to connect the controller to the drives.
o
If the drives are hot-plug capable, connect the internal connector of the controller to the SAS
connector on the hot-plug drive cage.
o
If the drives are not hot-plug capable, connect the internal connector of the controller to the non-
hot-plug hard drives.
4.
5.
Close or replace the access panel, and secure it with thumbscrews, if any are present.
CAUTION: Do not operate the server for long periods with the access panel open or removed.
Operating the server in this manner results in improper airflow and improper cooling that can
lead to thermal damage.
Power up the server.
Connecting external storage
1.
2.
Power down the server.
Connect an external SAS cable to the external port of the controller.
a. Pull back the tab on the mini SAS 4x connector on the cable.
b. Insert the cable connector into the external port of the controller.
c. Release the tab.
3.
Connect the other end of the cable to the SAS input connector of the external storage enclosure.
o
If the enclosure uses a standard SAS 4x connector, insert the cable connector into the enclosure
connector, and then tighten the lock screws on the cable connector.
Installing the controller hardware 10
Download from Www.Somanuals.com. All Manuals Search And Download.
o
If the enclosure uses a mini SAS 4x connector, pull back the tab on the cable connector, insert
the cable connector into the enclosure connector, and then release the tab.
4.
5.
Power up the enclosure.
Power up the server.
SAS cable part numbers
To order additional cables, use the option kit part number.
Approximate cable
length
Type of cable
Option kit part
number
Cable assembly
number
1 m (3 ft)
2 m (6 ft)
—
Mini SAS 4x to standard SAS 4x
Mini SAS 4x to mini SAS 4x
Mini SAS 4x to standard SAS 4x
Mini SAS 4x to mini SAS 4x
Mini SAS 4x to standard SAS 4x
Mini SAS 4x to mini SAS 4x
Mini SAS 4x to standard SAS 4x
419570-B21
407339-B21
419571-B21
432238-B21
419572-B21
432239-B21
419573-B21
408908-002
407344-003
408908-003
407344-004
408908-004
407344-005
408908-005
4 m (13 ft)
—
6 m (20 ft)
—
Installing the controller hardware 11
Download from Www.Somanuals.com. All Manuals Search And Download.
Updating the firmware
Methods for updating the firmware
To update the firmware on the server, controller, or hard drives, use Smart Components. These
components are available on the Firmware Maintenance CD. A more recent version of a particular server
or controller component might be available on the support page of the HP website
available from the software and drivers page for storage products
1.
2.
3.
Find the most recent version of the component that you require. Components for controller firmware
updates are available in offline and online formats.
Follow the instructions for installing the component on the server. These instructions are given with
the CD and are provided on the same Web page as the component.
Follow the additional instructions that describe how to use the component to flash the ROM. These
instructions are provided with each component.
For more information about updating the firmware, refer to the HP ProLiant Storage Firmware
Maintenance User Guide (for controller and hard drive firmware) or the HP Online ROM Flash User
Guide (for server firmware).
Updating the firmware 12
Download from Www.Somanuals.com. All Manuals Search And Download.
Configuring an array
Utilities available for configuring an array
Three utilities are available for configuring an array on an HP Smart Array controller: ORCA,
CPQONLIN, and ACU.
•
ORCA is a simple utility that is used mainly to configure the first logical drive in a new server before
the operating system is loaded.
•
•
CPQONLIN is a more full-featured utility for online configuration of servers that use Novell NetWare.
ACU is an advanced utility that enables you to perform many complex configuration tasks.
For more information about the features of these utilities and for instructions for using the utilities, see the
Configuring Arrays on HP Smart Array Controllers Reference Guide. This guide is available on the
Documentation CD that is provided in the controller kit.
Whichever utility you use, remember the following factors when you build an array:
•
•
All drives in an array must be of the same type (for example, all SAS or all SATA).
For the most efficient use of drive space, all drives within an array should have approximately the
same capacity. Each configuration utility treats every physical drive in an array as if it has the same
capacity as the smallest drive in the array. Any excess capacity of a particular drive cannot be used
in the array and so is unavailable for data storage.
•
The more physical drives that there are in an array, the greater the probability that the array will
experience a drive failure during any given period. To guard against the data loss that occurs when
a drive fails, configure all logical drives in an array with a suitable fault-tolerance (RAID) method.
Configuring an array 13
Download from Www.Somanuals.com. All Manuals Search And Download.
Setting the boot controller and controller order
Setting a controller as the boot controller
The following procedure enables you only to set a controller as the boot controller. If you also want to
adjust the boot order settings of other controllers in the system, use RBSU instead ("Setting the controller
1.
Confirm that the controller is connected to a logical drive. (If it is not, it cannot be set as the boot
controller.)
2.
3.
Perform a normal system shutdown.
Restart the server.
POST runs, and all controllers in the server are initialized one at a time in the current boot order
sequence. If a controller is connected to one or more hard drives, an ORCA prompt message
appears during the initialization process for that controller.
As soon as you see the ORCA prompt for the controller that you want to set as the boot controller,
continue with the next step.
4.
Press the F8 key.
The ORCA main menu appears. If the controller is configured with a logical drive, one of the menu
options is to set the controller as the boot controller.
5.
6.
Select the appropriate menu option, and follow any subsequent on-screen instructions. If prompted to
save the settings, do so.
If you want to configure or reconfigure an array on this controller, you can do this while you are still
in ORCA. (For more information, see the Configuring Arrays on HP Smart Array Controllers
Reference Guide. This guide is available on the Documentation CD that is provided in the controller
kit.)
If you do not want to configure an array at this time or if you intend to use a different utility to
configure the array, exit from ORCA, and then restart the server for the new boot controller setting to
take effect.
Setting the controller order
1.
Power up the server.
The server runs the POST sequence and briefly displays an RBSU prompt.
At the prompt, press the F9 key to start RBSU.
Follow the on-screen instructions to set the boot order for the different controllers in the system.
Save the settings.
2.
3.
4.
5.
Exit from the utility.
Setting the boot controller and controller order 14
Download from Www.Somanuals.com. All Manuals Search And Download.
For more information about using RBSU, refer to the HP ROM-Based Setup Utility User Guide or the server
setup and installation guide. These documents are both available on the Documentation CD supplied in
the server kit.
Setting the boot controller and controller order 15
Download from Www.Somanuals.com. All Manuals Search And Download.
Installing device drivers and Management
Agents
Installing device drivers
The drivers for the controller are located on the Support Software CD or the SmartStart CD that is
Using the Support Software CD: Instructions for installing the drivers from the Support Software CD are
given in the leaflet that is supplied with the CD.
Using the SmartStart CD: If you use the Assisted Installation path feature of SmartStart to install the
operating system on a new server, the drivers are automatically installed at the same time.
You can also use SmartStart to update the drivers manually on systems that are already configured. For
more information, refer to the SmartStart documentation.
Installing Management Agents
If you use the Assisted Installation path feature of SmartStart to install the operating system on a new
server, the Management Agents are automatically installed at the same time.
You can update the Management Agents by using the latest versions of the agents from the HP website
Web page.
If the new agents do not function correctly, you might also need to update Systems Insight Manager. The
latest version of Systems Insight Manager is available for download at the HP website
Installing device drivers and Management Agents 16
Download from Www.Somanuals.com. All Manuals Search And Download.
Upgrading or replacing controller options
Replacing or adding a battery
CAUTION: Electrostatic discharge can damage electronic components. Be sure you are
properly grounded before beginning this procedure.
1.
Close all applications, and then power down the server. This procedure flushes all data from the
cache.
2.
o
If the LED is blinking every 2 seconds, data is still trapped in the cache. Restore system power,
and repeat the previous steps in this procedure.
o
If the LED is not lit, proceed with the next step.
WARNING: There is a risk of explosion, fire, or personal injury if the battery pack is not
removing any item that contains a battery pack.
3.
4.
Remove the controller from the server.
Pull the flanges on the battery clip outward (1), and then swivel the clip 180 degrees so that it rests
on the batteries (2).
5.
Slide the batteries toward the right edge of the controller, away from the bracket.
Upgrading or replacing controller options 17
Download from Www.Somanuals.com. All Manuals Search And Download.
6.
While holding the battery assembly, tilt the clip until it is at about 30 degrees to the batteries, and
then push the clip in line with the clip hinges until the clip detaches from the batteries.
The rest of the procedure depends on whether you are replacing a battery or adding one.
o
o
If you are replacing a battery, continue with the next step.
If you are only adding an optional third battery, go to step 9.
7.
Separate the batteries.
a. Turn the batteries over.
b. Pull the lip on the right battery case away from the edge of the adjacent battery case (1).
c. Slide the batteries apart (2).
8.
Dispose of the exhausted or faulty battery using environmentally approved procedures ("Battery
Upgrading or replacing controller options 18
Download from Www.Somanuals.com. All Manuals Search And Download.
9.
Position the new battery and the remaining good battery as indicated, and then push them together
and slide them until they are aligned. The batteries combine into one unit.
10. Install the battery clip.
a. Position the clip so that the hinges on the clip are next to the appropriate hinge pillars on the
batteries.
b. Hold the clip at about 30 degrees to the batteries.
c. Push the clip at the hinges until the clip clicks into place.
11. Reinstall the batteries.
a. Hold the controller board near the DIMM socket and at the top and right edges to minimize
bending of the board.
Upgrading or replacing controller options 19
Download from Www.Somanuals.com. All Manuals Search And Download.
b. Position the batteries so that the pegs A on the underside of each battery are in the appropriate
holes B on the controller board and pegs C are in slots D.
c. Slide the batteries toward the board bracket until they are firmly seated against the connectors
on the cache module.
12. Secure the battery clip to the controller board:
a. Swivel the clip over the cache module (1).
Upgrading or replacing controller options 20
Download from Www.Somanuals.com. All Manuals Search And Download.
b. Push the clip firmly at both ends (2) until it clicks into place under the controller board.
13. Reinstall the controller in the server.
After installing a battery pack, you might see a POST message during reboot indicating that the array
accelerator (cache) is temporarily disabled. This behavior is normal because the new battery pack is likely
to have a low charge. You do not need to take any action because the recharge process begins
automatically when the battery pack is installed. The controller operates properly while the battery pack
recharges, although the performance advantage of the array accelerator is absent. When the battery
pack has been charged to a satisfactory level, the array accelerator is automatically enabled.
Replacing the cache module or controller
CAUTION: Electrostatic discharge can damage electronic components. Be sure you are
properly grounded before beginning this procedure.
1.
Close all applications, and then power down the server. This procedure flushes all data from the
cache.
2.
o
If the LED is blinking every 2 seconds, data is still trapped in the cache. Restore system power,
and repeat the previous steps in this procedure.
o
If the LED is not lit, proceed with the next step.
WARNING: There is a risk of explosion, fire, or personal injury if the battery pack is not
removing any item that contains a battery pack.
3.
Remove the controller from the server.
Upgrading or replacing controller options 21
Download from Www.Somanuals.com. All Manuals Search And Download.
4.
Pull the flanges on the battery clip outward (1), and then swivel the clip 180 degrees so that it rests
on the batteries (2).
5.
6.
Swivel the latches on the DIMM connector outward (1).
Slide the battery assembly and the cache module off the controller board (2).
The procedure at this point depends on whether you are replacing the controller or the cache
module.
o
o
If you are replacing the controller, go directly to the next step.
If you are replacing the cache module, pull it out of the battery assembly, install the new cache
module in its place, and go to the next step.
7.
Install the cache module and batteries on the controller board.
a. Hold the controller board near the DIMM connector and at the top and right edges to minimize
bending of the board.
Upgrading or replacing controller options 22
Download from Www.Somanuals.com. All Manuals Search And Download.
b. Position the batteries so that the pegs A on the underside of each battery are in the appropriate
holes B on the controller board and pegs C are in slots D.
c. Slide the batteries toward the board bracket until the connectors on the cache module are firmly
seated in the DIMM connector. (When the cache module is correctly seated, the gold contacts on
the cache module are completely hidden within the DIMM connector.)
8.
Secure the battery clip to the controller board.
a. Swivel the clip over the cache module (1).
Upgrading or replacing controller options 23
Download from Www.Somanuals.com. All Manuals Search And Download.
b. Push the clip firmly at both ends (2) until it clicks into place under the controller board.
9.
Reinstall the controller in the server.
Upgrading or replacing controller options 24
Download from Www.Somanuals.com. All Manuals Search And Download.
Replacing, moving, or adding hard drives
Identifying the status of a hard drive
When a drive is configured as a part of an array and connected to a powered-up controller, the
condition of the drive can be determined from the illumination pattern of the hard drive status lights (LEDs).
Item
1
Description
Fault/UID LED (amber/blue)
Online LED (green)
2
Online/activity
LED (green)
Fault/UID LED
(amber/blue)
Interpretation
On, off, or flashing Alternating amber
and blue
The drive has failed, or a predictive failure alert has been
received for this drive; it also has been selected by a
management application.
On, off, or flashing Steadily blue
The drive is operating normally, and it has been selected by a
management application.
On
On
Amber, flashing
regularly (1 Hz)
A predictive failure alert has been received for this drive.
Replace the drive as soon as possible.
Off
The drive is online, but it is not active currently.
Replacing, moving, or adding hard drives 25
Download from Www.Somanuals.com. All Manuals Search And Download.
Online/activity
LED (green)
Fault/UID LED
(amber/blue)
Interpretation
Flashing regularly Amber, flashing
(1 Hz) regularly (1 Hz)
Do not remove the drive. Removing a drive may terminate the
current operation and cause data loss.
The drive is part of an array that is undergoing capacity
expansion or stripe migration, but a predictive failure alert has
been received for this drive. To minimize the risk of data loss, do
not replace the drive until the expansion or migration is
complete.
Flashing regularly Off
(1 Hz)
Do not remove the drive. Removing a drive may terminate the
current operation and cause data loss.
The drive is rebuilding, or it is part of an array that is undergoing
capacity expansion or stripe migration.
Flashing irregularly Amber, flashing
regularly (1 Hz)
The drive is active, but a predictive failure alert has been
received for this drive. Replace the drive as soon as possible.
Flashing irregularly Off
The drive is active, and it is operating normally.
Off
Steadily amber
A critical fault condition has been identified for this drive, and
the controller has placed it offline. Replace the drive as soon as
possible.
Off
Off
Amber, flashing
regularly (1 Hz)
A predictive failure alert has been received for this drive.
Replace the drive as soon as possible.
Off
The drive is offline, a spare, or not configured as part of an
array.
Recognizing hard drive failure
A steadily glowing Fault LED indicates that that drive has failed. Other means by which hard drive failure
is revealed are:
•
The amber LED on the front of a storage system illuminates if failed drives are inside. (However, this
LED also illuminates when other problems occur, such as when a fan fails, a redundant power supply
fails, or the system overheats.)
•
A POST message lists failed drives whenever the system is restarted, as long as the controller detects
at least one functional drive.
•
•
ACU represents failed drives with a distinctive icon.
Systems Insight Manager can detect failed drives remotely across a network. (For more information
about Systems Insight Manager, refer to the documentation on the Management CD.)
•
ADU lists all failed drives.
For additional information about diagnosing hard drive problems, refer to the HP Servers Troubleshooting
Guide.
CAUTION: Sometimes, a drive that has previously been failed by the controller may seem to
be operational after the system is power-cycled or (for a hot-pluggable drive) after the drive
has been removed and reinserted. However, continued use of such marginal drives may
eventually result in data loss. Replace the marginal drive as soon as possible.
Replacing, moving, or adding hard drives 26
Download from Www.Somanuals.com. All Manuals Search And Download.
Effects of a hard drive failure
When a hard drive fails, all logical drives that are in the same array are affected. Each logical drive in
an array might be using a different fault-tolerance method, so each logical drive can be affected
differently.
•
RAID 0 configurations cannot tolerate drive failure. If any physical drive in the array fails, all non-
fault-tolerant (RAID 0) logical drives in the same array will also fail.
•
RAID 1+0 configurations can tolerate multiple drive failures as long as no failed drives are mirrored
to one another.
•
•
RAID 5 configurations can tolerate one drive failure.
RAID 6 (ADG) configurations can tolerate the simultaneous failure of two drives.
Compromised fault tolerance
If more hard drives fail than the fault-tolerance method allows, fault tolerance is compromised, and the
logical drive fails. In this case, all requests from the operating system are rejected with unrecoverable
errors. You are likely to lose data, although it can sometimes be recovered (refer to "Recovering from
One example of a situation in which compromised fault tolerance may occur is when a drive in an array
fails while another drive in the array is being rebuilt. If the array has no online spare, any logical drives
in this array that are configured with RAID 5 fault tolerance will fail.
Compromised fault tolerance can also be caused by non-drive problems, such as a faulty cable or
temporary power loss to a storage system. In such cases, you do not need to replace the physical drives.
However, you may still have lost data, especially if the system was busy at the time that the problem
occurred.
Recovering from compromised fault tolerance
If fault tolerance is compromised, inserting replacement drives does not improve the condition of the
logical volume. Instead, if the screen displays unrecoverable error messages, perform the following
procedure to recover data:
1.
Power down the entire system, and then power it back up. In some cases, a marginal drive will work
again for long enough to enable you to make copies of important files.
If a 1779 POST message is displayed, press the F2 key to re-enable the logical volumes. Remember
that data loss has probably occurred and any data on the logical volume is suspect.
2.
3.
4.
Make copies of important data, if possible.
Replace any failed drives.
After you have replaced the failed drives, fault tolerance may again be compromised. If so, cycle the
power again. If the 1779 POST message is displayed:
a. Press the F2 key to re-enable the logical drives.
b. Recreate the partitions.
c. Restore all data from backup.
To minimize the risk of data loss that is caused by compromised fault tolerance, make frequent backups of
all logical volumes.
Replacing, moving, or adding hard drives 27
Download from Www.Somanuals.com. All Manuals Search And Download.
Replacing hard drives
The most common reason for replacing a hard drive is that it has failed. However, another reason is to
gradually increase the storage capacity of the entire system.
If you insert a hot-pluggable drive into a drive bay while the system power is on, all disk activity in the
array pauses for a second or two while the new drive is spinning up. When the drive has achieved its
normal spin rate, data recovery to the replacement drive begins automatically (as indicated by the
blinking Online/Activity LED on the replacement drive) if the array is in a fault-tolerant configuration.
If you replace a drive belonging to a fault-tolerant configuration while the system power is off, a POST
message appears when the system is next powered up. This message prompts you to press the F1 key to
start automatic data recovery. If you do not enable automatic data recovery, the logical volume remains
in a ready-to-recover condition and the same POST message appears whenever the system is restarted.
Factors to consider before replacing hard drives
Before replacing a degraded drive:
•
Open Systems Insight Manager, and inspect the Error Counter window for each physical drive in the
same array to confirm that no other drives have any errors. (For details, refer to the Systems Insight
Manager documentation on the Management CD.)
•
•
•
Be sure that the array has a current, valid backup.
Confirm that the replacement drive is of the same type (SAS or SATA) as the degraded drive.
Use replacement drives that have a capacity at least as great as that of the smallest drive in the
array. The controller immediately fails drives that have insufficient capacity.
In systems that use external data storage, be sure that the server is the first unit to be powered down and
the last to be powered back up. Taking this precaution ensures that the system does not erroneously mark
the drives as failed when the server is powered up.
To minimize the likelihood of fatal system errors, take these precautions when removing failed drives:
•
Do not remove a degraded drive if any other drive in the array is offline (the Online/Activity LED is
off). In this situation, no other drive in the array can be removed without data loss.
The following cases are exceptions:
o
When RAID 1+0 is used, drives are mirrored in pairs. Several drives can be in a failed condition
simultaneously (and they can all be replaced simultaneously) without data loss, as long as no two
failed drives belong to the same mirrored pair.
o
o
When RAID 6 (ADG) is used, two drives can fail simultaneously (and be replaced simultaneously)
without data loss.
If the offline drive is a spare, the degraded drive can be replaced.
•
Do not remove a second drive from an array until the first failed or missing drive has been replaced
and the rebuild process is complete. (The rebuild is complete when the Online/Activity LED on the
front of the drive stops blinking.)
The following cases are exceptions:
o
o
In RAID 6 (ADG) configurations, any two drives in the array can be replaced simultaneously.
In RAID 1+0 configurations, any drives that are not mirrored to other removed or failed drives
can be simultaneously replaced offline without data loss.
Replacing, moving, or adding hard drives 28
Download from Www.Somanuals.com. All Manuals Search And Download.
Automatic data recovery (rebuild)
When you replace a hard drive in an array, the controller uses the fault-tolerance information on the
remaining drives in the array to reconstruct the missing data (the data that was originally on the replaced
drive) and write it to the replacement drive. This process is called automatic data recovery, or rebuild. If
fault tolerance is compromised, this data cannot be reconstructed and is likely to be permanently lost.
If another drive in the array fails while fault tolerance is unavailable during rebuild, a fatal system error
can occur, and all data on the array is then lost. In exceptional cases, however, failure of another drive
need not lead to a fatal system error. These exceptions include:
•
•
•
Failure after activation of a spare drive
Failure of a drive that is not mirrored to any other failed drives (in a RAID 1+0 configuration)
Failure of a second drive in a RAID 6 (ADG) configuration
Time required for a rebuild
The time required for a rebuild varies considerably, depending on several factors:
•
The priority that the rebuild is given over normal I/O operations (you can change the priority setting
by using ACU)
•
•
•
•
•
•
The amount of I/O activity during the rebuild operation
The rotational speed of the hard drives
The availability of drive cache
The brand, model, and age of the drives
The amount of unused capacity on the drives
For RAID 5 and RAID 6 (ADG), the number of drives in the array
Allow approximately 15 minutes per gigabyte for the rebuild process to be completed. This figure is
conservative; the actual time required is usually less than this.
System performance is affected during the rebuild, and the system is unprotected against further drive
failure until the rebuild has finished. Therefore, replace drives during periods of low activity when
possible.
When automatic data recovery has finished, the Online/Activity LED of the replacement drive stops
blinking steadily at 1 Hz and begins to either glow steadily (if the drive is inactive) or flash irregularly (if
the drive is active).
CAUTION: If the Online/Activity LED on the replacement drive does not light up while the
corresponding LEDs on other drives in the array are active, the rebuild process has abnormally
terminated. The amber Fault LED of one or more drives might also be illuminated. Refer to
Abnormal termination of a rebuild
If the Online/Activity LED on the replacement drive permanently ceases to be illuminated even while other
drives in the array are active, the rebuild process has abnormally terminated. The following table
indicates the three possible causes of abnormal termination of a rebuild.
Replacing, moving, or adding hard drives 29
Download from Www.Somanuals.com. All Manuals Search And Download.
Observation
Cause of rebuild termination
None of the drives in the array have
an illuminated amber Fault LED.
One of the drives in the array has
experienced an uncorrectable read error.
The replacement drive has an
illuminated amber Fault LED.
The replacement drive has failed.
One of the other drives in the array
has an illuminated amber Fault LED.
The drive with the illuminated Fault LED has
now failed.
Each of these situations requires a different remedial action.
Case 1: An uncorrectable read error has occurred.
1.
Back up as much data as possible from the logical drive.
CAUTION: Do not remove the drive that has the media error. Doing so causes the logical drive
to fail.
2.
3.
Restore data from backup. Writing data to the location of the unreadable sector often eliminates the
error.
Remove and reinsert the replacement drive. This action restarts the rebuild process.
If the rebuild process still terminates abnormally:
1.
2.
Delete and recreate the logical drive.
Restore data from backup.
Case 2: The replacement drive has failed.
Verify that the replacement drive is of the correct capacity and is a supported model. If these factors are
not the cause of the problem, use a different drive as the replacement.
Case 3: Another drive in the array has failed.
A drive that has recently failed can sometimes be made temporarily operational again by cycling the
server power.
1.
2.
Power down the server.
Remove the replacement physical drive (the one undergoing a rebuild), and reinstall the drive that it
is replacing.
3.
Power up the server.
If the newly failed drive seems to be operational again:
1.
2.
Back up any unsaved data.
Remove the drive that was originally to be replaced, and reinsert the replacement physical drive. The
rebuild process automatically restarts.
3.
When the rebuild process has finished, replace the newly failed drive.
However, if the newly failed drive has not recovered:
1.
2.
3.
Remove the drive that was originally to be replaced, and reinsert the replacement physical drive.
Replace the newly failed drive.
Restore data from backup.
Replacing, moving, or adding hard drives 30
Download from Www.Somanuals.com. All Manuals Search And Download.
Upgrading hard drive capacity
You can increase the storage capacity on a system even if there are no available drive bays by swapping
drives one at a time for higher capacity drives. This method is viable as long as a fault-tolerance method
is running.
CAUTION: Because it can take up to 15 minutes per gigabyte to rebuild the data in the new
configuration, the system is unprotected against drive failure for many hours while a given
drive is upgraded. Perform drive capacity upgrades only during periods of minimal system
activity.
To upgrade hard drive capacity:
1.
2.
Back up all data.
Replace any drive. The data on the new drive is re-created from redundant information on the
remaining drives.
CAUTION: Do not replace any other drive until data rebuild on this drive is complete.
When data rebuild on the new drive is complete, the Online/Activity LED stops flashing steadily and
either flashes irregularly or glows steadily.
3.
Repeat the previous step for the other drives in the array, one at a time.
When you have replaced all drives, you can use the extra capacity to either create new logical drives or
extend existing logical drives. For more information about these procedures, refer to the HP Array
Configuration Utility User Guide.
Moving drives and arrays
You can move drives to other ID positions on the same array controller. You can also move a complete
array from one controller to another, even if the controllers are on different servers.
Before you move drives, the following conditions must be met:
•
•
The server must be powered down.
If moving the drives to a different server, the new server must have enough empty bays to
accommodate all the drives simultaneously.
•
•
•
The array has no failed or missing drives, and no spare drive in the array is acting as a replacement
for a failed drive.
The controller is not running capacity expansion, capacity extension, or RAID or stripe size
migration.
The controller is using the latest firmware version (recommended).
If you want to move an array to another controller, all drives in the array must be moved at the same time.
When all the conditions have been met:
1.
Back up all data before removing any drives or changing configuration. This step is required if you
are moving data-containing drives from a controller that does not have a battery-backed cache.
2.
3.
Power down the system.
Move the drives.
Replacing, moving, or adding hard drives 31
Download from Www.Somanuals.com. All Manuals Search And Download.
4.
5.
Power up the system. If a 1724 POST message appears, drive positions were changed successfully
and the configuration was updated.
If a 1785 (Not Configured) POST message appears:
a. Power down the system immediately to prevent data loss.
b. Return the drives to their original locations.
c. Restore the data from backup, if necessary.
Adding drives
You can add hard drives to a system at any time, as long as you do not exceed the maximum number of
drives that the controller supports. You can then either build a new array from the added drives or use the
extra storage capacity to expand the capacity of an existing array.
To perform an array capacity expansion, use ACU. If the system is using hot-pluggable drives and ACU is
running in the same environment as the normal server applications, you can expand array capacity
without shutting down the operating system. For more information, see the Configuring Arrays on HP
Smart Array Controllers Reference Guide.
The expansion process is illustrated in the following figure, in which the original array (containing data) is
shown with a dashed border, and the newly added drives (containing no data) are shown unshaded. The
array controller adds the new drives to the array and redistributes the original logical drives over the
enlarged array one logical drive at a time. This process liberates some storage capacity on each physical
drive in the array. Each logical drive keeps the same fault-tolerance method in the enlarged array that it
had in the smaller array.
When the expansion process has finished, you can use the liberated storage capacity on the enlarged
array to create new logical drives. Alternatively, you can use ACU to enlarge (extend) one of the original
logical drives.
Replacing, moving, or adding hard drives 32
Download from Www.Somanuals.com. All Manuals Search And Download.
Diagnosing array problems
Controller board runtime LEDs
Immediately after the server is powered up, the controller runtime LEDs illuminate briefly in a
predetermined pattern as part of the POST sequence. At all other times during server operation, the
illumination pattern of the runtime LEDs indicates the status of the controller, as described in the following
table.
LED ID
Color
LED name and interpretation
1
Green
CR502: Expander Heartbeat LED. This LED flashes every 2 seconds during
normal operation. Abnormal conditions are indicated as follows:
•
•
If the LED glows steadily, the expander has an internal problem.
If the LED flashes twice per second, the NVRAM is corrupt.
In either case, the expander does not function.
CR510: System Error LED.
2
3
4
Amber
Amber
Amber
CR509: Diagnostics Error LED.
CR500: Drive Failure LED. A physical drive connected to the controller has failed.
Check the Fault LED on each drive to determine which drive has failed.
5
6
7
Green
Green
Green
CR508: Activity LED for SAS port 4I.
CR507: Activity LED for SAS port 3I.
CR506: Command Outstanding LED. The controller is working on a command
from the host driver.
8
Green
CR505: Controller Heartbeat LED. This LED flashes every 2 seconds to indicate
the controller health.
Diagnosing array problems 33
Download from Www.Somanuals.com. All Manuals Search And Download.
LED ID
Color
LED name and interpretation
9
Green
CR504: Gas Pedal LED. This LED, together with item 10, indicates the amount of
controller CPU activity. For details, see the following table.
10
Green
CR503: Idle Task LED. This LED, together with item 9, indicates the amount of
controller CPU activity. For details, see the following table.
Gas pedal LED
status
Idle task LED
status
Controller CPU activity level
Off
Blinking
Off
0–25%
Blinking
On steadily
On steadily
25–50%
50–75%
75–100%
Off
On steadily
Battery pack LEDs
Item ID Color
Description
1
Green
System Power LED. This LED glows steadily when the
system is powered up and 12 V system power is
available. This power supply is used to maintain the
battery charge and provide supplementary power to the
cache microcontroller.
2
Green
Auxiliary Power LED. This LED glows steadily when 3.3V
auxiliary voltage is detected. The auxiliary voltage is used
to preserve BBWC data and is available any time that the
system power cords are connected to a power supply.
3
4
Amber
Green
Battery Health LED. To interpret the illumination patterns of
this LED, see the following table.
BBWC Status LED. To interpret the illumination patterns of
this LED, see the following table.
Diagnosing array problems 34
Download from Www.Somanuals.com. All Manuals Search And Download.
LED3 pattern
LED4 pattern
Interpretation
—
One blink every
two seconds
The system is powered down, and the cache contains data that has
not yet been written to the drives. Restore system power as soon as
possible to prevent data loss.
Data preservation time is extended any time that 3.3 V auxiliary
power is available, as indicated by LED 2. In the absence of
auxiliary power, battery power alone preserves the data. A fully-
charged battery can normally preserve data for at least two days.
The battery lifetime also depends on the cache module size. For
further information, refer to the controller QuickSpecs on the HP
—
—
Double blink,
then pause
The cache microcontroller is waiting for the host controller to
communicate.
One blink per
second
The battery pack is below the minimum charge level and is being
charged. Features that require a battery (such as write cache,
capacity expansion, stripe size migration, and RAID migration) are
temporarily unavailable until charging is complete. The recharge
process takes between 15 minutes and two hours, depending on the
initial capacity of the battery.
—
—
Steady glow
Off
The battery pack is fully charged, and posted write data is stored in
the cache.
The battery pack is fully charged, and there is no posted write data
in the cache.
One blink per
second
One blink per
second
An alternating green and amber blink pattern indicates that the
cache microcontroller is executing from within its boot loader and
receiving new flash code from the host controller.
Steady glow
—
There is a short circuit across the battery terminals or within the
battery pack. BBWC features are disabled until the battery pack is
replaced. The life expectancy of a battery pack is typically more
than three years.
One blink per
second
—
There is an open circuit across the battery terminals or within the
battery pack. BBWC features are disabled until the battery pack is
replaced. The life expectancy of a battery pack is typically more
than three years.
Diagnostic tools
Several diagnostic tools provide feedback about problems with arrays. The most important are:
•
•
•
ADU
The meanings of the various ADU error messages are provided in the HP Servers Troubleshooting
Guide.
POST messages
Smart Array controllers produce diagnostic error messages at reboot. Many of these POST messages
are self-explanatory and suggest corrective actions. For more information about POST messages,
refer to the HP Servers Troubleshooting Guide.
Server Diagnostics
Diagnosing array problems 35
Download from Www.Somanuals.com. All Manuals Search And Download.
To use Server Diagnostics:
a. Insert the SmartStart CD into the server CD-ROM drive.
b. Click Agree when the license agreement appears, and click the Maintenance tab.
c. Click Server Diagnostics, and follow the on-screen prompts and instructions.
Diagnosing array problems 36
Download from Www.Somanuals.com. All Manuals Search And Download.
Electrostatic discharge
Preventing electrostatic discharge
To prevent damaging the system, be aware of the precautions you need to follow when setting up the
system or handling parts. A discharge of static electricity from a finger or other conductor may damage
system boards or other static-sensitive devices. This type of damage may reduce the life expectancy of the
device.
To prevent electrostatic damage:
•
•
•
•
•
Avoid hand contact by transporting and storing products in static-safe containers.
Keep electrostatic-sensitive parts in their containers until they arrive at static-free workstations.
Place parts on a grounded surface before removing them from their containers.
Avoid touching pins, leads, or circuitry.
Always be properly grounded when touching a static-sensitive component or assembly.
Grounding methods to prevent electrostatic
discharge
Several methods are used for grounding. Use one or more of the following methods when handling or
installing electrostatic-sensitive parts:
•
Use a wrist strap connected by a ground cord to a grounded workstation or computer chassis. Wrist
straps are flexible straps with a minimum of 1 megohm 10 percent resistance in the ground cords.
To provide proper ground, wear the strap snug against the skin.
•
Use heel straps, toe straps, or boot straps at standing workstations. Wear the straps on both feet
when standing on conductive floors or dissipating floor mats.
•
•
Use conductive field service tools.
Use a portable field service kit with a folding static-dissipating work mat.
If you do not have any of the suggested equipment for proper grounding, have an authorized reseller
install the part.
For more information on static electricity or assistance with product installation, contact an authorized
reseller.
Electrostatic discharge 37
Download from Www.Somanuals.com. All Manuals Search And Download.
Regulatory compliance notices
Federal Communications Commission notice
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant
to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment. This equipment generates,
uses, and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference, in which case the user will be required to correct
the interference at personal expense.
Modifications
The FCC requires the user to be notified that any changes or modifications made to this device that are
not expressly approved by Hewlett-Packard Company may void the user’s authority to operate the
equipment.
Cables
Connections to this device must be made with shielded cables with metallic RFI/EMI connector hoods in
order to maintain compliance with FCC Rules and Regulations.
Canadian notice
This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment
Regulations.
Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel
brouilleur du Canada.
European Union regulatory notice
This product complies with the following EU Directives:
•
•
Low Voltage Directive 2006/95/EC
EMC Directive 2004/108/EC
Compliance with these directives implies conformity to applicable harmonized European standards
(European Norms) which are listed on the EU Declaration of Conformity issued by Hewlett-Packard for this
product or product family.
This compliance is indicated by the following conformity marking placed on the product:
Regulatory compliance notices 38
Download from Www.Somanuals.com. All Manuals Search And Download.
This marking is valid for non-Telecom products and EU harmonized Telecom products (e.g. Bluetooth).
This marking is valid for EU non-harmonized Telecom products.
*Notified body number (used only if applicable—refer to the product label)
Hewlett-Packard GmbH, HQ-TRE, Herrenberger Strasse 140, 71034 Boeblingen, Germany
BSMI notice
Japanese class A notice
Korean class A notice
Battery replacement notice
This component uses a nickel metal hydride (NiMH) battery pack.
Regulatory compliance notices 39
Download from Www.Somanuals.com. All Manuals Search And Download.
WARNING: There is a risk of explosion, fire, or personal injury if a battery pack is
mishandled. To reduce this risk:
• Do not attempt to recharge the batteries if they are disconnected from the controller.
• Do not expose the battery pack to water, or to temperatures higher than 60°C (140°F).
• Do not abuse, disassemble, crush, or puncture the battery pack.
• Do not short the external contacts.
• Replace the battery pack only with the designated HP spare.
• Battery disposal should comply with local regulations.
Batteries, battery packs, and accumulators should not be disposed of together with the general
household waste. To forward them to recycling or proper disposal, use the public collection system
or return them to HP, an authorized HP Partner, or their agents.
For more information about battery replacement or proper disposal, contact an authorized reseller or an
authorized service provider.
Taiwan battery recycling notice
The Taiwan EPA requires dry battery manufacturing or importing firms in accordance with Article 15 of
the Waste Disposal Act to indicate the recovery marks on the batteries used in sales, giveaway or
promotion. Contact a qualified Taiwanese recycler for proper battery disposal.
Regulatory compliance notices 40
Download from Www.Somanuals.com. All Manuals Search And Download.
Acronyms and abbreviations
ACU
Array Configuration Utility
ADG
Advanced Data Guarding (also known as RAID 6)
ADU
Array Diagnostics Utility
BBWC
battery-backed write cache
CPQONLIN
NetWare Online Array Configuration Utility
DIMM
dual inline memory module
LED
light-emitting diode
ORCA
Option ROM Configuration for Arrays
PCIe
peripheral component interconnect express
POST
Power-On Self Test
RBSU
ROM-Based Setup Utility
Acronyms and abbreviations 41
Download from Www.Somanuals.com. All Manuals Search And Download.
Index
diagnostic tools 35
drive failure, detecting 26
A
ACU (Array Configuration Utility) 13
ADU (Array Diagnostic Utility) 35
Array Configuration Utility (ACU) 13
array controller installation overview 7
Array Diagnostic Utility (ADU) 35
E
electrostatic discharge 37
array, configuring 13
automatic data recovery (rebuild) 29
extending logical drive capacity 32
B
batteries, replacing 17
batteries, specifications 5
battery pack LEDs 34
board components 5
F
Federal Communications Commission (FCC)
firmware, updating 12
C
G
cache, features 5
cache, replacing 21
H
hard drive capacity, upgrading 31
hard drive, replacing 28
hard drives, determining status of 25
configuring an array 13
connectors 5
CPQONLIN 13
hard drives, types supported 5
I
D
installation overview 7
Index 42
Download from Www.Somanuals.com. All Manuals Search And Download.
J
S
Server Diagnostics utility 35
spares, battery pack, part number 5
specifications, controller 5
K
Korean notices 39
static electricity 37
L
storage capacity, increasing 31
storage devices, connecting 10
summary of installation procedure 7
LEDs, controller 33
T
Taiwan battery recycling notice 40
troubleshooting 33
M
Management Agents, updating 16
U
O
upgrading drive capacity 31
Option ROM Configuration for Arrays (ORCA) 13
ORCA (Option ROM Configuration for Arrays) 13,
overview of installation process 7
P
power requirements 5
preparation procedures 9
previously configured server, installation in 7
R
replacing the batteries 17
replacing the cache module 21
replacing the controller 21
ROM, updating 12
Index 43