| Standby Power Rating   100 kW 60 Hz   Liquid Cooled Gas Engine Generator Sets   Whisper-Test™   Low Speed Exercise   61 dB(A) at 23 feet   GENERAC 6.8L ENGINE   Naturally Aspirated   Gaseous Fueled   UL 2200 Listed   Transfer Switch is sold separately   STANDARD EQUIPMENT   • • • • • • • • • • • UV/Ozone resistant hoses   Watertight state of the art electrical connectors   Mainline circuit breaker   Oil drain extension to frame rail   Radiator drain extension   • • • • • • • • • • • All input connections in one single area   High coolant temperature shutdown   Low oil pressure shutdown   Low coolant level automatic shutdown   Low fuel pressure   Battery charge alternator   Overspeed automatic shutdown   Adjustable cranking timer   Adjustable exercise timer   Oil drain extension   Cool flow radiator   2 Amp static battery charger   Battery, battery rack and battery cables   Fan and belt guards   Isochronous governor   Flex fuel line pigtail   Closed coolant recovery system   FEATURES   • • • • • • Built-in kW, kVAR and power factor meters   Watertight electrical connectors   Rodent proof construction   High efficiency, low distortion Generac designed alternator   Vibration isolated from mounting base   Matching Generac transfer switches engineered and   tested to work as a system   All components easily accessible for maintenance   Electrostatically applied powder paint   • • • • • • • • • Innovative design and fully prototype tested   UL 2200 Listed   Solid state frequency compensated voltage regulator   Dynamic and static battery charger   Sound attenuated acoustically designed enclosure   Whisper-Test™ for low noise level exercise   Acoustically designed engine cooling system   High flow low noise factory engineered exhaust system   State of the art digital control system with H-100   microprocessor control panel   • • COMMERCIAL SERIES   Download from Www.Somanuals.com. All Manuals Search And Download.   COMMERCIAL 100 kW   OPERATING DATA   KW RATING   COMMERCIAL SERIES   COMMERCIAL 100 kW   100   ENGINE SIZE   6.8 Liter V-10   GENERATOR OUTPUT VOLTAGE/KW - 60Hz   120/240V, single phase, 1.0 pf   120/208V, 3-phase, 0.8 pf   120/240V, 3-phase, 0.8 pf   277/480V, 3-phase, 0.8 pf   KW   AMP   CB Size   100 LP / 98 NG   100 LP / 98 NG   100 LP / 98 NG   100 LP / 98 NG   416.6 LP / 408.3 NG   347.4 LP / 340.4 NG   301 LP / 295 NG   150.5 LP / 147.5 NG   450   400   350   175   GENERATOR LOCKED ROTOR KVA   AVAILABLE @ VOLTAGE DIP OF 35%   Single phase or 208V & 240V 3-phase   480V 3-phase   190   225   ENGINE FUEL CONSUMPTION (Natural Gas) (Propane)   Natural Gas   (ft /hr.)   130   371   713   994   1260   Propane   3 (gal/hr.)   1.42   4.06   7.81   10.88   13.80   cu ft/hr   Exercise cycle   52.3   149.4   287.4   400.4   507.8   25% of rated load   50% of rated load   75% of rated load   100% of rated load   ENGINE COOLING   Air flow (inlet air including alternator and combustion air)   System coolant capacity   Heat rejection to coolant   Max. operating air temp. on radiator   Max. ambient temperature   3 ft /min   5,500   4.5   342,000   60 (150)   50 (140)   US gal.   BTU/hr.   °C (°F)   °C (°F)   COMBUSTION AIR REQUIREMENTS   Flow at rated power 60 Hz   cfm   262   SOUND EMISSIONS IN DBA   db(A) @ 23 feet in exercise mode   db(A) @ 23 feet at normal operating load   61   72   EXHAUST   Exhaust flow at rated output 60 Hz   Exhaust temp. at muffler outlet   cfm   °F   888   960   ENGINE PARAMETERS   Rated synchronous RPM   HP at rated KW   60 Hz   60 Hz   2300   168   POWER ADJUSTMENT FOR AMBIENT CONDITIONS   Temperature Deration   3% for every 10 °C above - °C   1.65% for every 10 °F above - °F   25   77   Altitude Deration   1% for every 100 m above - m   3% for every 1000 ft. above - ft.   183   600   RATING: All three phases units are rated at 0.8 power factor. All single phase units are rated at 1.0 power factor. STANDBY RATING: Standby ratings apply to installations served by a reliable utility   source. The standby rating is applicable to varying loads for the duration of a power outage. There is no overload capability for this rating. Ratings are in accordance with ISO-3046-1. Design and   specifications are subject to change without notice. Maximum wattage and current are subject to and limited by such factors as fuel Btu content, ambient temperature, altitude, engine power   and condition, etc.   Download from Www.Somanuals.com. All Manuals Search And Download.   INTERCONNECTIONS   COMMERCIAL 100 kW   100   100   100   100   240 1 ø   208 3ø   240 3ø   480 3ø   450   400   350   175   3-2/0 to 400 mcm   2-3/0 to 500 mcm   2-3/0 to 500 mcm   #6 to 350 mcm   COMMERCIAL SERIES   INSTALLATION LAYOUT   NOTE:   Door access   from both sides   UNIT WEIGHT: Steel 2705 lbs., Aluminum 2531 lbs.   GENERAC® POWER SYSTEMS, INC. • P.O. BOX 297 • WHITEWATER, WI 53190   www.guardiangenerators.com   Bulletin 0174700SBY / Printed in USA 06.07, 08.07   Download from Www.Somanuals.com. All Manuals Search And Download.   © 2007 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice.   |