Greenway Home Products Water Dispenser VGS2 PC User Manual

Dual Stage  
Water Filtration  
System  
Système de  
filtration d’eau  
Double étape  
Sistema de  
filtrado de agua  
de etapa doble  
Use & Care Guide  
Guide d’utilisation  
et d’entretien  
Manual d uso  
y cuidado  
VGS2-PC  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Thank-you for choosing the vitapur® VGS2-PC to meet your water treatment neeeds. We have carefully engineered your Dual Stage Water  
Filtration System to provide you with years of touble-frree operation.  
1. Safety Instructions  
The installation of this system must be in accordance with all provincial/state and/or local laws and regulations regarding plumbing services.  
Installation by a certified plumber is recommended. Always comply with the following warnings and safety instructions, to prevent bodily injury  
or property damage.  
Do not attempt to install, operate, clean or perform routine maintenance on your VGS2-PC system unless you have first read and  
understood all of the warnings and safety instructions that are contained in this manual and on the labels that are affixed to the  
VGS2-PC system.  
Do not attempt to operate the VGS2-PC system if it has been visibly damaged, (e.g., due to abuse in shipping) or if it may have  
sustained damage, (e.g., if the unit has been dropped).  
To prevent faulty operation of the system, inspect it carefully to ensure it is free of leaks and physical damage before using.  
Never start the VGS2-PC system (e.g., after the initial installation) before confirming that the exterior is dry and that there  
are no visible leaks.  
To prevent damage to the unit, always install the VGS2-PC system indoors, where it will not be exposed to the elements.  
Always install and operate the unit in an environment where both the air and water temperatures will normally range between 41°F  
(5°C) and 100°F (37.7°C).  
Always stop the inlet water flow before performing any maintenance on the unit.  
Always drain all water from the unit, cap the Inlet and Outlet Ports, and drain and disconnect all plumbing lines, if temperatures  
should fall below freezing (0°C / 32°F).  
The VGS2-PC filtration system is designed for use with microbiologically safe water only. Do not use on water that is  
microbiologically unsafe or of unknown origin without adequate disinfection before or after the system.  
2. Product Overview  
The vitapur® Dual Stage Water Filtration System has been engineered to rigid standards, and has been quality inspected at the factory prior to  
packaging. Please review this manual in its entirety for a detailed system explanation, and ensure that the following components accompany  
this system:  
Filter Housing  
1/4” Tubing  
1
2
3
4
5
1
6
Sediment /  
Adapter /  
Particulate Filter  
Supply Valve  
4
Carbon Block Filter  
Faucet  
6
7
Faucet  
Hardware  
3
7
2
5
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
To ensure system performance, all replacement components must be purchased directly from an authorized dealer or directly from Greenway  
Home Products. The use of components purchased from other sources will void the warranty, and will potentially cause the system to function  
in a lesser capacity than intended.  
Filter cartridges should be replaced every 4-6 months, or when the pressure drop through the cartridges inhibit water flow to the point where  
pressure losses are being experienced.  
The VGS2-PC is intended for the supplemental treatment of disinfected public drinking water or other drinking water which has been tested and  
deemed acceptable for human consumption by the provincial/state or local health agency having jurisdiction. The VGS2-PC should not be used  
on water that is microbiologically unsafe or of unknown origin without adequate disinfection before or after the system.  
If you will be using an untreated surface water or groundwater source (rather than a municipal supply source) that has been deemed  
acceptable for human consumption by the provincial/state or local health agency having jurisdiction, additional pre-treatment of the water prior  
to the VGS2-PC may be required.  
The filtration provided with the VGS2-PC is 5 µm nominal, and is not suitable for the reduction of protozoan cysts.  
2.1 About Your System  
Specifications  
Flow Rate Range  
VGS2-PC  
3.8 LPM / 1 GPM  
Unit Dimensions (L x W x H)  
Shipping Weight  
26.7cm/10.5” x 13cm/5.125” x 33.3cm/13.125”  
2.1 kg / 4.6 lbs.  
Operating Pressure Range  
Feed Water Temperature Range  
Unit Volume  
0 - 60 PSI  
41 – 100 -0F (5 – 37.7 0C)  
1.4 L / 0.37 Gal.  
Inlet Port Size  
Outlet Port Size  
1/4” Quick Connect  
1/4” Quick Connect  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. Installation Instructions  
3.1 Accessibility, Orientation & Fittings  
Mount the VGS2-PC in a location that provides ample space for replacement of filter cartridges. It is recommended that you maintain at least  
6”(15 cm) of clear space below the VGS2-PC for this purpose.  
3.2 Installation  
Attach  
Drill & Mount  
Mount  
Connect  
1
2
3
4
3.3 Initial Start-up Procedure  
The VGS2-PC system has been designed to be installed on the cold water line only.  
The presence of small air bubbles in the water system may occasionally give the water a milky appearance, but air bubbles will not affect water  
quality or taste. Initially, filtered water may appear cloudy due to the release of air trapped within the filters and throughout the system.  
Dependant upon your use of the system, this condition should disappear within a few days following system installation.  
Always perform the following start-up procedure when starting your VGS2-PC system for the first time after a storage period:  
1. Shut off the main water supply valve.  
2. Mark and drill mounting location for the faucet.  
3. Install faucet with the hardware provided.  
4. Mount the VGS2-PC system to the inside cabinet wall. Please ensure that when mounting the system, a proper sized screw is  
utilized so as not to penetrate the cabinet wall.  
5. Install adapter valve on cold water line and ensure plumbing for sink faucet is correctly secured to the top of the adapter.  
6. Hook up inlet water connections from the adapter valve to the filter inlet port, and outlet water port to the base of the faucet using  
the 1/4” tubing provided.  
7. Confirm that all of the plumbing connections are secured, and partially open the main water supply valve.  
8. If no leaks are visible, fully open the main supply valve. Check for leaks.  
9. Slowly open the adapter supply valve and check system for leaks.  
10. Open the faucet and flush the filtration system for 5 minutes.  
11. Your VGS2-PC system is now ready for use.  
4. Service and Maintenance  
4.1 Accredited Service Technician  
Whenever you require assistance, visit www.greenwayhp.com or please call the Customer Service Department at: 1-866-253-0447.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
4.2 Filter Replacement  
Filter cartridge life varies depending on usage, and/or water conditions. Changes in taste, color, and flow of the water being filtered indicate that  
the cartridge should be replaced. It is recommended that the filter cartridges be replaced every 4-6 months.  
Replace sooner if water pressure at faucet begins to drop noticeably or cartridge fails to perform satisfactory.  
WARNING: The filters used in the VGS2-PC system are not universal filters. Use of any other filter in the system will void the warranty.  
Replacement filters model #VGSRF2-PC.  
Close Supply Valve  
Remove  
Untwist  
Replace  
2
3
1
4
Do not use with water that is microbiologically unsafe or with water of unknown quality without adequate disinfection before or after the system.  
Procedure for replacing filter cartridge:  
1. Turn off the water supply to the system.  
2. Depress the red pressure relief buttons on both filter housings, (a small amount of water may come out of the release valve  
when the pressure is released).  
3. Using both hands, loosen the filter housing in the clockwise direction.  
4. When the filter housing is turning, hold onto it with both hands while backing the housing off the threads. The housing,  
filled with water and a wet filter is heavy, be cautious and ensure that you are adequately positioned to support the weight.  
5. Remove the old filter and dispose in the trash. Used filters are not considered hazardous waste.  
6. Empty the housing of water and insert the new filter cartridge. Make sure that the o-ring on the filter housing has not fallen off  
when dumping the excess water or removing the old filter.  
7. Attach the filter housing onto the system.  
8. Lightly tighten the filter housing back into position with your hands.  
9. Refill the system by opening the inlet water line just enough to fill the housings with water.  
10.Check the system for leaks.  
11. If no leaks are evident, open the inlet water line completely and recheck for leaks.  
12. Flush the system for a minimum of 5 minutes prior to use.  
4.3 Replacement Components Ordering Information  
Please contact the Customer Service Department in Canada: 1-866-253-0447 in the USA: 1-866-282-0533.  
Quantity  
Replacement part no.  
Part description  
per unit  
Filter Head  
1
Z Z. 0 5 . 2 0 0 0  
Z Z . 0 5 . 2 0 0 1  
Z Z . 0 5 . 2 0 0 2  
Z Z . 0 5 . 2 0 0 3  
V G S R F 2 - P C  
1/4” Tubing  
1
Adapter/Supply Valve  
Faucet (including hardware)  
1
1
Dual Pack Replacement Filters  
(sediment & carbon block)  
N/A  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
5. Troubleshooting Guide  
Problem  
Possible Cause  
Suggested Solution  
Pressure Drop.  
Filter(s) clogged.  
Replace filter cartridge.  
(More than 40 psi loss at 1GPM).  
VGS2-PC leaking water.  
Misaligned or cross-threaded ports  
Reinstall to ensure a good solid connection  
with ports.  
Excessive water pressure (beyond 80 psi).  
Water Hammer causing pressure spikes.  
Install pressure regulator ahead of  
system.  
Install a Water Hammer* Arrestor in system.  
Water is milky.  
Small air bubbles are trapped in water.  
Air purging from new filters / system.  
Leave tap on for short time.  
Find source of air bubbles and correct.  
System is vibrating.  
Not mounted securely.  
Secure fasteners.  
Water Hammer* causing vibrations.  
Install a Water Hammer* Arrestor in system.  
Outlet water has bad taste.  
Filters not installed.  
Ensure filters are in position.  
Filter / housings not seated properly.  
Ensure that the filters are correctly seated  
in the housing, and that the housing are  
seating properly.  
Testing / source indentification /  
additional pre-treatment required  
Testing should be conducted to  
determine cause of bad taste. Additional  
pre-treatment may be required.  
Outlet water is dirty (particulate matter)  
or has undesirable color.  
Filter not installed.  
Ensure filters are in position.  
Filter(s) / housing(s) not seated properly.  
Ensure the filters are correctly seated  
in the housing, and that the housing are  
seating properly.  
* Water Hammer: Sudden closure of a control valve or stopping of a pump produces excess pressure in a pipeline. The hydraulic engineer, water  
supply designer and pumping system operator have the responsibility to ensure the surges due to Water Hammer are within acceptable limits  
and can be dampened as quickly as possible.  
Note: If you experience trouble with your system other than the symptoms described above, please visit www.greenwayhp.com or contact the  
Customer Service Department at 1-866-253-0447.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  

Grizzly Lathe G9036 User Manual
Groupe SEB USA T FAL Toaster Avanti Elite User Manual
Hamilton Beach Griddle Electric Griddle User Manual
Harbor Freight Tools Automobile Battery Charger 93784 User Manual
Heat Glo LifeStyle Indoor Fireplace SL 550TV D User Manual
Hotpoint Freezer hm315x f User Manual
Hotpoint Freezer HUT161I User Manual
HP Hewlett Packard Calculator 40gs User Manual
Huskee Lawn Mower HU500N22SH User Manual
Hypertec Carrying Case N15948PHY User Manual