Graham Field Respiratory Product JB112 070 User Manual

Neb-u-Tyke®  
®
Nebulizer Compressor  
Item JB0112-070  
User Manual  
Read this manual before operating the nebulizer.  
Save this manual for future reference.  
Info: The most current version of this manual  
can be found online at www.grahamfield.com.  
Federal Law (USA) restricts this device to sale by or  
on the order of a physician. This device should not  
be used unless the operator has been instructed by  
a qualified healthcare professional.  
JB0112-070-INS-LAB-RevB14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INTRODUCTION  
This user manual contains important information  
and safety precautions for the John Bunn Neb-u-Tyke  
Neb-a-Doodle Nebulizer Compressor.  
Before using your Nebulizer Compressor, please read and  
understand this entire user manual. Take special note of all  
safety precautions marked DANGER and WARNING. Save  
this user manual for future reference.  
Intended Use  
The Compressor Nebulizer System is designed to provide  
a source of compressed air for aerosol therapy. It is used  
in conjunction with a jet (pneumatic) nebulizer to produce  
medicated aerosols for inhalation by pediatric and adult  
patients with respiratory symptoms.  
Indications for therapy include asthma, chronic bronchitis,  
infection of the upper respiratory tract, chronic  
obstructive pulmonary disease, and other respiratory  
disorders in accordance with a physician’s prescription.  
Do not use this product for any other purpose than the  
preceding. This device can be used with adult or pediatric  
patients under physician’s prescription.  
The intended use of the Neb-a-Doodle Drawing Board is  
drawing, writing, and doodling only.  
JB0112-070-INS-LAB-RevB14  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Symbols Key  
O
Off  
I
~
On  
Alternating current  
IPX0  
Enclosed equipment without protection against ingress of water  
Attention (read the instructions)  
II  
Class II (not applicable for UL1431)  
BF: This product is in accordance with the degree of protection against electric  
shock for type BF equipment. (not applicable for UL1431)  
Disposal of Electrical & Electronic Equipment (WEEE): This product should  
not be treated as household waste, but submitted to an appropriate collection  
point for the recycling of electrical and electronic equipment. For more detailed  
information about the recycling of this product, please contact your local city  
office, household waste disposal service, or the Graham-Field authorized  
distributor from whom you purchased this product.  
JB0112-070-INS-LAB-RevB14  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
IMPORTANT SAFETY PRECAUTIONS  
When using electrical products, especially when children  
are present, always follow basic safety precautions,  
including the following:  
DANGER: Indicates a potential hazard situation or unsafe  
practice that, if not avoided, will result in death or serious  
personal injury.  
WARNING: Indicates a potential hazard situation or unsafe  
practice that, if not avoided, could result in death or  
serious personal injury.  
CAUTION: Indicates a potential hazard or unsafe practice  
that, if not avoided, could result in minor or moderate  
personal injury.  
s NOTICE: Indicates a potential hazard or unsafe practice  
that, if not avoided, could result in product or property  
damage.  
Info: Provides application recommendations or other useful  
information to ensure that you get the most from your  
product.  
READ ALL INSTRUCTIONS BEFORE USING  
DANGER: To reduce the risk of electrocution:  
1. Always unplug this product immediately after use.  
2. Do not use this product while bathing, showering,  
washing dishes, or close to water sources of any kind.  
3. Do not place or store device where it can fall or be pulled  
into a tub or sink.  
4. Do not place device in or drop into water or other liquid.  
5. Do not reach for a device that has fallen into water.  
Unplug it immediately.  
JB0112-070-INS-LAB-RevB14  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
WARNING: To reduce the risk of burns, electrocution, fire  
or personal injury:  
1. Never leave this device unattended when plugged in.  
2. This product contains small parts that may present  
a choking hazard to small children, and the tubing  
may present a strangulation hazard. Always use close  
supervision when this device is used by or near children  
or those who require close supervision.  
3. Children under the age of 3, or any patient who is unable  
to use a mouthpiece properly under supervision, should  
use a mask.  
4. Use this device only as intended and described in this  
manual. Do not use attachments or accessories not  
recommended by GF Health Products, Inc.  
5. Never operate this product if:  
a. it has a damaged cord or plug,  
b. it is not working properly,  
c. it has been dropped or damaged, or  
d. it has been dropped into water.  
Return the product to your Graham-Field authorized  
distributor for examination and repair.  
6. Keep the cord away from heated surfaces.  
7. Never block the air openings of this product or place it  
on a soft surface, such as a bed or couch, where the air  
openings may be blocked. Keep the air openings free of  
lint, hair and the like.  
8. Never drop or insert any object into any openings or hose.  
9. Never use this device while drowsy or sleeping.  
10. Do not use this device outdoors or operate where aerosol  
(spray) products are being used.  
11. Do not use this device in the presence of flammable  
anesthesia or where oxygen or nitrous oxide is being  
administered. This device has no AP or APG protection.  
12. Connect this device to a properly grounded outlet only.  
JB0112-070-INS-LAB-RevB14  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
13. This device has a polarized plug (one blade is wider  
than the other). As a safety feature, this plug will fit into  
a polarized outlet only one way. If the plug does not fit  
fully into the outlet, reverse the plug. If it still does not fit,  
contact a qualified electrician. Do not modify the plug in  
any way. Do not attempt to defeat this safety feature.  
14. Unplug the device before filling or cleaning the nebulizer.  
15. This device is oil-free. Do not lubricate.  
16. Do not remove the jet nebulizer while the device is operating.  
17. Do not leave medication inside the jet nebulizer when it is  
not in use.  
18. Use the nebulizer intermittently; the maximum operating  
period is 30 minutes. The nebulizer must stand unused for  
30 minutes between uses.  
19. The mouthpiece and masks are for use by one person  
only; in order to avoid infection, do not share them.  
20. Notice for California Customers- California Proposition 65  
WARNING: This product contains a chemical known to the  
State of California to cause cancer and reproductive or  
developmental harm.  
JB0112-070-INS-LAB-RevB14  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
PRODUCT DESCRIPTION  
Features and Components  
Please note nebulizer features and components, labeled in  
the illustration below.  
filter cap  
air outlet connector  
for tubing  
ON/OFF switch  
push button  
tubing  
reservoir tube  
mouthpiece  
nebulizer  
housing  
drawing  
board  
nebulizer cup  
T adapter  
adult mask  
pediatric mask  
shapes  
slide tab  
stylus  
Neb-u-Tyke Neb-a-Doodle  
Nebulizer Compressor  
Info: Neb-a-Doodle replacement parts are available at  
distributor.  
JB0112-070-INS-LAB-RevB14  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
SETUP  
Info: Before initial operation, clean the nebulizer  
cup assembly following the instructions given in  
MAINTENANCE/Cleaning the Nebulizer Cup.  
WARNING: Ensure that the nebulizer compressor is  
unplugged during setup.  
1. Before each use, inspect the compressor and nebulizer  
cup assembly for damage or wear; replace as needed.  
2. Place the compressor on a table or other flat stable  
surface (not on the floor), in an area that is clean and  
dust-free. Be sure you can easily reach the controls  
when seated.  
3. Open the nebulizer medication cup: Twist the cap  
counter-clockwise until it stops, then lift cap off.  
4. Pour the prescribed medication into the nebulizer  
medication cup. Do not fill with more than 5 ml per  
treatment.  
cap  
5. Install cap on cup. Turn clockwise  
cup  
to tighten.  
install cap  
on cup  
6. If using the mouthpiece for  
treatment, proceed to step 7. If  
using a mask, install the bottom  
mask  
part of the mask directly onto the  
cap  
top of the nebulizer medication cup  
cap as shown at right. Proceed to  
step 9.  
install mask  
on cap  
T adapter  
mouthpiece  
7. Insert mouthpiece into large end of  
T adapter.  
assemble  
mouthpiece  
and T adapter  
JB0112-070-INS-LAB-RevB14  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
Info: The reservoir tube, shown in the illustration earlier in  
this manual, acts as a holding tank for the mist, reducing the  
amount lost during treatment. Its use is optional. If you wish  
to use the reservoir tube, install it now on the small end of  
the T adapter.  
8. Install T adapter onto top of  
T adapter  
nebulizer medication cup cap.  
cup  
9. Connect the tubing to the adapter on  
the bottom of the nebulizer medication  
cup.  
install  
T adapter  
on cap  
10. Connect the tubing's other end  
to the compressor air outlet  
connector.  
WARNING: Before use, check that all parts are securely  
connected. Use of an improperly assembled nebulizer  
could diminish or prevent adequate delivery of medication  
and the effectiveness of the treatment.  
JB0112-070-INS-LAB-RevB14  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
arrow  
push button  
OPERATION  
Info: The drawing board must  
be removed from the nebulizer  
housing before use. To remove  
the drawing board, push the  
button and slide the drawing  
1
2
board in the opposite direction from the cover arrow.  
Nebulizer Operation  
s NOTICE: The Neb-u-Tyke Neb-a-Doodle Nebulizer  
Compressor is designed for intermittent use only. Do not  
operate it continuously for more than 30 minutes for a  
single use without turning it off and allowing a cooling  
period of least 30 minutes.  
1. Ensure that the ON/OFF switch is in the OFF position.  
2. Plug the power cord into a properly grounded electrical  
wall outlet.  
3. Move the ON/OFF switch to the ON position to start the  
compressor.  
4. Place the nebulizer mouthpiece between teeth and  
close mouth (or install the mask on face).  
5. As aerosol starts flowing, inhale deeply and slowly  
through mouthpiece (or mask).  
WARNING: Never use a nebulizer with a clogged nozzle.  
If the nozzle is clogged, the aerosol mist will be reduced,  
altered or stopped, which will diminish or eliminate the  
effectiveness of the treatment. If clogging occurs, replace  
the nebulizer.  
Info: If you need to interrupt treatment, move the ON/OFF  
switch to the OFF position.  
6. When the treatment is complete, move the ON/OFF  
switch to the OFF position to turn off the compressor.  
7. Unplug the compressor from power outlet.  
8. Disconnect nebulizer from tubing.  
9. Clean nebulizer as instructed in MAINTENANCE/  
Cleaning the Nebulizer Cup.  
JB0112-070-INS-LAB-RevB14  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Drawing Board Operation  
arrow  
push button  
1
2
To remove the drawing board, push the button and slide  
the drawing board in the opposite direction from the cover  
arrow.  
To install the drawing board, insert the drawing board on  
the side with the housing arrow that matches the cover  
arrow, then push it all the way to secure it to the lock  
button. This ensures the drawing board stays in place. To  
prevent damage to the unit, ensure you do not insert it  
from the other direction.  
To draw on the drawing board, move the included stylus  
pen, pointed end down, along the drawing board. To use  
the included shapes, place them on the drawing board and  
press lightly.  
To erase the drawing board, move the slide tab over the  
drawing board.  
WARNING: This product contains small parts that may  
present a choking hazard to small children. Always use  
close supervision when this device is used by or near  
children or those who require close supervision.  
JB0112-070-INS-LAB-RevB14  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Safety Overload  
s NOTICE: Do not exceed 30 minutes of continuous  
operation.  
1. The motor of this device has a built-in thermal overload  
protector. Should the motor overheat, the protector  
will automatically shut off the motor. Should this occur,  
move the ON/OFF switch to the OFF position and allow  
the motor to cool down for approximately 30 minutes  
before turning it on again.  
2. If the overload protector shuts off the motor frequently,  
you may have an unstable voltage situation.  
3. If the device shuts down and cannot restart, it may  
need to be replaced. Call your Graham-Field authorized  
distributor immediately.  
JB0112-070-INS-LAB-RevB14  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MAINTENANCE  
Cleaning the Compressor’s Outer Case  
WARNING: Electrical shock hazard. Do not remove  
the outer case of the device. All disassembly and  
maintenance of the device must be performed by a  
qualified service technician. Refer service to qualified  
service personnel.  
WARNING: This device does not require oil. Do not  
attempt to lubricate any internal parts.  
WARNING: Unplug device before cleaning. Do not  
submerge in water for cleaning.  
Wipe the compressor's outer case with a clean, damp cloth  
weekly to keep it dust-free. Do not use any powdered type  
cleaners or soap.  
Cleaning the Nebulizer Cup  
All parts of the disposable nebulizer, except tubing, should  
be thoroughly cleaned after each use. If your physician  
specifies a specific cleaning procedure, follow that  
procedure.  
WARNING: To prevent possible risk of infection from  
contaminated medication, clean the nebulizer after each  
treatment.  
1. After each use, disassemble the nebulizer cup, T  
adapter and mouthpiece completely, wash all parts in  
warm soapy water, and rinse thoroughly. Allow to air  
dry. Store in a clean, dry location.  
2. Once daily, after washing as above, soak nebulizer  
components in a fresh solution consisting of one part  
warm water and one part white vinegar for 30 minutes  
followed by a warm water rinse. Allow to air dry. Store  
in a clean, dry location.  
Cleaning the Drawing Board  
Wipe the drawing board outside cover with a clean, damp  
cloth weekly. Do not use any liquid, cleansers or soap on  
any surface of the drawing board.  
JB0112-070-INS-LAB-RevB14  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Replacing the Filter  
s NOTICE: Change the filter once every 30 days or when the  
filter changes color. Additional filters can be purchased  
authorized distributor.  
1. Ensure that ON/OFF switch is in the OFF position. Open  
the filter cap located next to the ON/OFF switch.  
2. Remove the dirty filter with a small, pointed object.  
Discard the filter.  
3. Replace with a clean filter.  
4. Replace the filter cap.  
s NOTICE: Do not use cotton or other materials as a filter.  
s NOTICE: Do not wash or clean the filter.  
s NOTICE: Do not reuse the filter. Do not operate  
compressor without a filter. Compressor damage can  
result.  
WARNING: The disposable nebulizer kit is for single  
patient use only.  
Storage  
Keep the device and accessories dry. Avoid exposure to  
direct sunlight.  
JB0112-070-INS-LAB-RevB14  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TROUBLESHOOTING  
If your Neb-u-Tyke Neb-a-Doodle Nebulizer Compressor  
fails to function, consult the following Troubleshooting  
guide. If the problem persists, consult your Graham-Field  
authorized distributor.  
Problem  
Device doesn’t  
operate  
Cause and Solution  
Check if plug is properly fit into a grounded electrical outlet.  
When device has been run continuously for more than 30 minutes  
just before using, auto-shut-down may have been activated by the  
built-in thermal protector; ensure that device is OFF for at least 30  
minutes before next usage.  
Nebulization is  
weak  
Check for proper electrical voltage.  
Check tubing for blockage or air leakage at connection to Neb-u-Tyke  
compressor or nebulizer cup; replace as needed.  
Check that the nebulizer cup is properly assembled and not  
damaged. If there is any damage, replace as needed.  
Check if filter is dirty; replace filter as needed.  
JB0112-070-INS-LAB-RevB14  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SPECIFICATIONS  
Specification  
Description  
Max pressure (compressor) 32.5 PSI  
Max flow rate  
Nebulization rate  
Particle dimension  
Capacity  
Approximately 12 LPM  
.33 ml/min  
.5 - 5 microns  
5 ml  
Filter  
Sponge  
Dimensions (LxWxH)  
Weight  
10" × 6.5" × 4.2" (255 mm x 166 mm x 108 mm)  
4 lb (1860 g)  
Electrical requirement  
Current  
115VAC/60Hz  
1.2A (rate)  
Fuse  
2.5A 250V  
Power cord  
Plug  
Black, 7.5 ft (90") / 2,286 mm  
2-prong type  
56.5 dBA  
Sound level  
Environment  
Temperature Operation: 41°F to 104°F (5°C to 40°C)  
Storage: -40°F to 158°F (-40°C to 70°C)  
Humidity  
Operation: 30% to 95% RH  
Storage: 10% to 95% RH  
JB0112-070-INS-LAB-RevB14  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
LIMITED WARRANTY  
SCOPE OF WARRANTY  
GF Health Products, Inc. (“GF”) warrants to the original purchaser only that it  
will replace or repair components, at GF’s sole discretion, that are defective  
in material or workmanship under normal use and service. All warranties  
are conditioned upon the proper use of the products strictly in accordance  
with good commercial practice and applicable GF instructions and manuals,  
including proper use and maintenance. To the extent that a component is  
warranted by a third party, GF conveys all of its rights under that warranty to  
the original purchaser, to the extent permitted.  
This limited warranty shall only apply to defects that are reported to GF’s  
customer service team within the applicable warranty period and which, upon  
examination by GF or its authorized representative, prove to be a warranty  
item. This limited warranty is not transferable.  
The warranted components and time period are set forth below:  
Compressor:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .five years  
Accessories: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .six months  
The applicable warranty period shall commence from date of shipment to  
the original customer, unless there is an expiration date on the component in  
which case the warranty shall expire on the earlier of warranty period or the  
expiration date.  
OBTAINING WARRANTY SERVICE  
A GF Customer Service Representative must authorize warranty service.  
Please contact the GF Customer Service department by calling 678-291-3207,  
sending a fax request to 770-368-2386 or by e-mailing a request to cs@  
grahamfield.com. Specific directions will be provided by the Customer Service  
Representative. Failure to abide by the specific directions will result in denial  
of the warranty claim.  
EXCLUSIONS  
The warranty does not cover and GF shall not be liable for the following:  
1) Defects, damage, or other conditions caused, in whole or in part, by  
misuse, abuse, negligence, alteration, accident, freight damage, tampering  
or failure to seek and obtain repair or replacement in a timely manner;  
2) Products which are not installed, used, or properly cleaned and maintained  
as required in the official manual for the applicable product;  
3) Products considered to be of a non-durable nature including, but not  
limited to: casters, filters, fuses, gaskets, lubricants, and charts;  
4) Accessories or parts not provided by GF;  
5) Charges by anyone for adjustments, repairs, replacement parts, installation  
or other work performed upon or in connection with such products which  
are not expressly authorized in writing, in advance, by GF;  
6) Any labor or shipping charges incurred in the replacement part installation  
or repair;  
7) Costs and expenses of regular maintenance and cleaning; and  
8) Representations and warranties made by any person or entity other than  
GF.  
JB0112-070-INS-LAB-RevB14  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ENTIRE WARRANTY, EXCLUSIVE REMEDY AND CONSEQUENTIAL  
DAMAGES DISCLAIMER  
THIS WARRANTY IS GF’S ONLY WARRANTY AND IS IN LIEU OF ALL OTHER  
WARRANTIES, EXPRESS OR IMPLIED. GF MAKES NO IMPLIED WARRANTIES OF  
ANY KIND INCLUDING ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR  
FITNESS FOR A PARTICULAR PURPOSE.  
IF ANY MODEL OR SAMPLE WAS SHOWN TO THE CUSTOMER, SUCH MODEL  
OR SAMPLE WAS USED MERELY TO ILLUSTRATE THE GENERAL TYPE AND  
QUALITY OF THE PRODUCT AND NOT TO REPRESENT THAT THE PRODUCT  
WOULD NECESSARILY CONFORM TO THE MODEL OR SAMPLE IN ALL  
RESPECTS.  
THIS WARRANTY IS LIMITED TO THE REPAIR OR REPLACEMENT OF  
THE DEFECTIVE PARTS. GF SHALL NOT BE LIABLE FOR AND HEREBY  
DISCLAIMS ANY DIRECT, SPECIAL, INDIRECT, INCIDENTAL, EXEMPLARY OR  
CONSEQUENTIAL DAMAGES, INCLUDING, BUT NOT LIMITED TO: DAMAGES  
FOR LOSS OF PROFITS OR INCOME, LOSS OF USE, DOWNTIME, COVER,  
OR EMPLOYEE OR INDEPENDENT CONTRACTOR WAGES, PAYMENTS AND  
BENEFITS.  
The warranties contained herein contain all the representations and  
warranties with respect to the subject matter of this document, and supersede  
all prior negotiations, agreements and understandings with respect thereto.  
The recipient of this document hereby acknowledges and represents that it  
has not relied on any representation, assertion, guarantee, warranty, collateral  
contract or other assurance, except those set out in this document.  
For additional information on this product or this warranty, please contact a  
GF Customer Service Representative.  
NOTES:  
1) Additional terms and conditions may apply.  
2) Freight claims must be notated on the Bill of Lading and must be made with  
immediacy. The ICC regulations govern specific requirements for freight  
claims. Failure to abide by those regulations may result in a denial of the  
freight claim. GF will assist you in filing the freight claim.  
3) Claims for any short shipment must be made within thirty (30) days of the  
invoice date.  
JB0112-070-INS-LAB-RevB14  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Manufactured for:  
GF Health Products, Inc.  
2935 Northeast Parkway  
Atlanta, Georgia 30360 USA  
Telephone: 770-368-4700  
Fax: 770-368-2386  
Made in China  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Neb-u-Tyke®  
®
Compresor de Nebulizador  
Modelo JB0112-070  
Manual de Usuario  
Lea antes de operar el nebulizador. Guarde este  
manual para referencia en el futuro.  
Info: La más reciente versión de este manual podrá  
ser encontrado en www.grahamfield.com.  
La Ley Federal (USA) restringe este aparato para  
ventas por la orden de su médico. Este aparato no  
debe ser utilizado si el operador no ha sido adiestrado  
por profesional de cuido de salud cualificado.  
JB0112-070-INS-LAB-RevB14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Este producto ha sido examinado y aprobado con los siguientes  
estándares:  
UL1431  
EN 60601-1  
CONTENIDOS  
INTRODUCCIÓN...................................................................................................3  
USO DEL COMPRESOR DE NEBULIZADOR..............................................3  
SÍMBOLOS ....................................................................................................4  
DIRECTIVAS IMPORTANTES DE SEGURIDAD .................................................5  
DESCRIPCIÓN DEL PRODUCTO........................................................................8  
CARACTERÍSTICAS Y COMPONENTES ....................................................8  
ENSAMBLAJE......................................................................................................9  
OPERACIÓN....................................................................................................... 11  
OPERACIÓN DEL COMPRESOR DE NEBULIZADOR.............................. 11  
OPERACIÓN DE LA TABLA DE DIBUJAR................................................12  
SEGURIDAD EN CASO DE SOBRECARGA .............................................13  
MANTENIMIENTO .............................................................................................14  
LIMPIEZA DE LA CARCASA DEL COMPRESOR .....................................14  
LIMPIEZA DE LA TAZA DEL NEBULIZADOR ...........................................14  
LIMPIEZA DE LA TABLA DE DIBUJAR .....................................................14  
INSTRUCCIONES PARA EL CAMBIO DEL FILTRO DE AIRE .................. 15  
ALMACENAJE ............................................................................................15  
DETECTANDO PROBLEMAS............................................................................16  
ESPECIFICACIONES .........................................................................................17  
GARANTÍA LIMITADA........................................................................................18  
GF Health Products, Inc. no es responsable de errores tipográficos. Para  
obtener la información más actualizada y vigente relativa a los envases,  
garantías, productos y especificaciones, incluyendo la versión más  
actualizada de estas instrucciones, por favor visite nuestro sitio web en  
Graham-Field, John Bunn, Neb-u-Tyke y Neb-a-Doodle son marcas registradas  
de GF Health Products, Inc. © 2009 GF Health Products, Inc.  
JB0112-070-INS-LAB-RevB14  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
INTRODUCCIÓN  
Este manual del usuario contiene información importante  
y precauciones de seguridad para el John Bunn Neb-u-Tyke  
Neb-a-Doodle Compresor de Nebulizador. Antes de usar  
su Compresor de Nebulizador, favor de leer y entender  
el manual de usuario. Tome nota especial en todas las  
precauciones marcadas PELIGRO y ADVERTENCIA. Guarde  
este manual de usuario para referencia en el futuro.  
Uso del Compresor de Nebulizador  
El Neb-u-Tyke Neb-a-Doodle Compresor de Nebulizador  
es diseñado para proveer una fuente de aire comprimido  
para la terapia de aerosol. Se usa en conjunto con  
un nebulizador de chorro (neumático) para producir  
aerosoles de medicamento para inhalación por pacientes  
adultos y pediátricos con síntomas respiratorios.  
Indicaciones para terapia incluye asma, bronquitis crónica,  
infección de la zona superior respiratorio, enfermedad  
pulmonar obstructiva crónica y otros desordenes que va  
de acuerdo con la receta de su médico. No debe usar este  
producto por cualquier otro propósito, que lo descrito  
arriba. Este aparato puede ser usado con pacientes adultos  
y pediátricos con la receta de su médico.  
El uso entendido del Neb-a-Doodle Tabla de Dibujo es  
dibujar, escribir y garabatear solamente.  
JB0112-070-INS-LAB-RevB14  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Símbolos  
O
Apagado  
I
~
Encendido  
Corriente alternando  
IPX0  
El equipo no tiene protección contra sumergiendo en agua  
Atención (lea las instrucciones)  
II  
Clase II (no aplicable para UL1431)  
BF: Este producto está en concordancia con el grado de protección sobre el  
riesgo de descarga eléctrica por equipo de tipo BF (no aplicable por UL1431).  
Disposición de Equipo Eléctrico y Electrónico (WEEE): Este producto no debe ser tratado  
como residuos domésticos, pero sometidos a un sitio de colección para reciclaje de equipo  
eléctrico y electrónico. Para más información detallada sobre el reciclaje de este producto,  
llame a su oficina de cuidad local, un servicio de disposición de residuos domésticos o a su  
distribuidor autorizado de Graham-Field de donde compró este producto.  
JB0112-070-INS-LAB-RevB14  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
DIRECTIVAS IMPORTANTES DE SEGURIDAD  
PELIGRO: Indica una situación de peligro o una practica  
insegura que, si no es evitada, resultará en muerte o  
heridas serias a la persona.  
ADVERTENCIA: Indica una situación de peligro o una  
practica insegura que, si no es evitada, puede resultar en  
muerte o heridas serias a la persona.  
PRECAUCIÓN: Indica una situación de peligro o una  
practica insegura que, si no es evitada, podría dar lugar a  
daños corporales de menor importancia.  
s AVISO: Indica una situación de peligro o una practica  
insegura que, si no es evitada, podría dar lugar a daños  
de menor importancia al producto o daños materiales.  
Info: Proporciona recomendaciones para la aplicación y  
otra información útil para asegurar que obtengas lo más que  
pueda del producto.  
LEE TODAS LAS INSTRUCCIONES ANTES DE UTILIZAR  
PELIGRO: para reducir el riesgo de electrocución.  
1. Siempre debe desconectar este producto inmediatamente  
después de usar.  
2. No debe usar durante el baño, lavando platos, y cerca de  
cualquier fuente de agua.  
3. No posicionar o almacenar donde pueda caer a la bañera  
o al lava manos.  
4. No debe introducir en agua u otro liquido. No debe  
recoger producto sumergido en agua. Desconecte  
inmediatamente.  
JB0112-070-INS-LAB-RevB14  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
ADVERTENCIA: Para reducir el riesgo de quemadura,  
electrocución, fuego o heridas a la persona.  
1. Este producto nunca debería ser desatendido mientras  
esté conectado.  
2. Este producto contiene piezas pequeñas que presenta  
riesgos de asfixia para niños, y la manga puede presentar  
riesgo de estrangulación. Supervisión cercana es  
necesaria cuando este producto esté utilizado cerca de  
niños o personas con impedimentos.  
3. Niños menores de 3 años, y cualquier paciente quien no  
puede usar la boquilla correctamente bajo supervisión,  
debe usar la máscara.  
4. Utilice este producto solamente como indicado en el  
manual de usuario. No utilice aditamentos o accesorios  
no recomendados por GF Health Products, Inc.  
5. Nunca utilice este producto si  
a. el enchufe o el cable está dañado,  
b. no funciona adecuadamente,  
c. ha sufrido caída o daño, o  
d. ha sido mojado o sumergido en agua.  
Devuelve este producto al centro de servicio para examen  
y/o arreglos.  
6. Mantenga el cable lejos de superficies calientes.  
7. Nunca obstruya entradas de aire del producto o utilice  
en una superficie suave tal como cama o sillón donde las  
entradas del aire pueden ser bloqueadas. Mantenga las  
entradas libres de pelusa, cabello, o materiales de este  
tipo.  
8. Nunca inserte objetos en cualquier entrada o manga.  
9. Nunca utilice soñoliento o dormido.  
10. No utilice al aire libre, ni opere donde se utilicen  
productos de aerosol.  
11. No utilice en presencia de anestesia, oxígeno, oxido  
nítrico, o cualquier gas inflamable mientras estos estén  
siendo administrado. Este aparato no tiene protección AP  
o APG.  
JB0112-070-INS-LAB-RevB14  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
12. Conecte este producto solamente en un enchufe de pared  
correcto.  
13. Este aparato tiene un enchufe polarizado (un aspa es más  
ancha que la otra). Para reducir el riesgo de electrocución,  
este enchufe es diseñado para poder ser posicionado  
de una sola manera en una toma eléctrica polarizada. Si  
el enchufe no entre completamente en la toma, invierta  
el enchufe. Si no funciona de este modo, contacte un  
electricista cualificado. No modifique el enchufe de ninguna  
manera.  
14. Desconecte el aparato antes de llenar el nebulizador.  
15. Este aparato no utiliza aceite. No lubrique.  
16. No debe remover el nebulizador de chorro cuando el  
aparato está operando.  
17. No debe dejar medicamento en el nebulizador cuando no  
esté en uso.  
18. Use el nebulizador por periodos: el periodo de operación  
máximo es 30 minutos. El nebulizador no debe ser usado  
por 30 minutos entre usos.  
19. La boquilla y las máscaras son para uso de una sola  
persona; para evitar infección no debe compartirlos.  
20. Aviso para los clientes de California - Proposición 65 de  
California ADVERTENCIA: Este producto contiene una  
sustancia química conocida en el estado de California por  
causar cáncer y daños reproductivos o del desarrollo.  
JB0112-070-INS-LAB-RevB14  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
DESCRIPCIÓN DEL PRODUCTO  
Características y componentes  
Por favor de tomar nota de las características y los  
componentes del nebulizador descritos en la ilustración  
abajo:  
tapa del filtro  
conector del  
enchufe de aire  
interruptor de ON/OFF  
botón  
manga  
manga de reserva  
boquilla  
compartimento  
de nebulizador  
tabla de  
dibujar  
taza del nebulizador  
adaptador T máscara adulta  
máscara pediátrica  
formas  
lengüeta  
lápiz  
Neb-u-Tyke Neb-a-Doodle  
Compresor de Nebulizador  
Info: Neb-a-Doodle piezas reemplazadas están disponibles  
Graham-Field.  
JB0112-070-INS-LAB-RevB14  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
ENSAMBLAJE  
Aviso: Antes de operación inicial, limpie la taza del  
nebulizador siguiendo las instrucciones escritos en la sección  
Mantenimiento/Limpieza de la Taza del Nebulizador.  
ADVERTENCIA: Antes de conectar el cordón de  
electricidad, asegure que el interruptor de ON/OFF está en  
la posición OFF.  
El enchufe también sirve para desconectar el aparato.  
1. Antes de uso, examine el compresor y taza de  
nebulizador para daño; reemplace si es necesario.  
2. Posicione el aparato en una superficie horizontal para  
que los controles estén con fácil acceso. No debe usar  
este aparato en el piso.  
3. Remueva la tapa de la taza del nebulizador.  
4. Inserte medicamento prescrito por su médico.  
tapa  
5. Reúne taza y tapa.  
taza  
ensamblaje de  
taza y tapa  
6. Si usa la boquilla para el tratamiento,  
proceda al paso 7. Si usa la máscara,  
máscara  
instale la parte inferior de la máscara  
directamente sobre la tapa de la taza  
tapa  
del nebulizador como demostrado a  
la derecha, entonces proceda al paso  
9.  
instale la máscara  
en la tapa  
adaptador T  
7. Conecte la boquilla a la parte  
boquilla  
grande del adaptador T.  
ensamblaje de  
adaptador T  
y boquilla  
JB0112-070-INS-LAB-RevB14  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
Info: La manga de reserva, en la ilustración superior del  
manual, es como un tanque de retención para reducir la  
cantidad de medicamento perdido durante tratamiento. Es  
opcional. Si desea usar la manga de reserva, posicione en la  
parte inferior del adaptador T.  
8. Instale el adaptador T sobre la  
adaptador T  
tapa de la taza del nebulizador.  
taza  
9. Conecte la manga al adaptador  
a la parte inferior de la taza  
nebulizador.  
instale adaptador T  
en tapa de la taza  
10. Conecte la otra parte de la manga al conector de mango  
del compresor.  
ADVERTENCIA: Antes de uso, verifique que todas las  
piezas están conectados correctamente. Uso de un  
nebulizador armado incorrectamente puede disminuir  
o impedir reparto adecuado de medicamento y la  
efectividad del tratamiento.  
JB0112-070-INS-LAB-RevB14  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
flecha  
botón  
OPERACIÓN  
Info: La tabla de dibujar tiene  
que ser apartado del nebulizador  
antes de uso. Para quitar la tabla  
de dibujar, empuje el botón y  
1
2
deslice la tabla de dibujar en la dirección opuesto de la flecha  
en la tapa.  
Operación del Compresor de Nebulizador  
s AVISO: El Compresor de Nebulizador está diseñado  
para uso solamente por periodos. No debe operarlo  
continuamente por más de 30 minutos en un uso sin  
apagarlo y dejar que se enfríe por lo menos 30 minutos.  
1. Asegurase que el interruptor eléctrico esté en la  
posición “OFF”.  
2. Conecte el cordón eléctrico en la toma eléctrica apropiada.  
3. Encienda el compresor posicionando el interruptor a ON.  
4. Acomode la boquilla del nebulizador entre los dientes y  
cierre la boca (o instale la máscara en la cara).  
5. Cuando el aerosol empiece a fluir, necesita inhalar  
profundamente y despacio a través de la boquilla o la  
máscara.  
ADVERTENCIA: Nunca debe usar el nebulizador con un  
inyector tapado. Si el inyector está tapado, la nube de  
aerosol será reducido, cambiado o parado, que puede  
diminuir o eliminar la efectividad del tratamiento. Si se  
tapa, reemplace el nebulizador.  
Info: Si el tratamiento necesita ser interruptado, posicione el  
interruptor a la posición OFF.  
6. Cuando el tratamiento haya terminado, apague el  
compresor posicionando el interruptor en la posición OFF.  
7. Desenchufe el aparato de la toma eléctrica.  
8. Desconecte el nebulizador del mango.  
9. Limpie el nebulizador siguiendo las instrucciones  
escritos en la sección Mantenimiento/Limpieza de la  
Taza del Nebulizador.  
JB0112-070-INS-LAB-RevB14  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operación de la Tabla de Dibujar  
flecha  
botón  
1
2
Para quitar la tabla de dibujar, empuje el botón y deslice la  
tabla de dibujar en la dirección opuesto que la flecha en la  
tapa.  
Para instalar la tabla de dibujar, inserte la tabla de dibujar  
en el lado con la flecha en el compartimento que machea  
la flecha en la tapa, y empuje hasta el final para asegurarlo  
con el botón de cerrar. Esto asegure que la tabla de dibujar  
se queda en su sitio. Para prevenir daño al aparato,  
asegure que no inserta la tapa por la otra dirección.  
Para dibujar en la tabla de dibujar, mueve el lápiz, punto  
hacia abajo, sobre la tabla de dibujar. Para usar las  
formas incluidos, coloca sobre la tabla de dibujar y apreté  
suavemente.  
Para borrar la tabla de dibujar, mueve la lengüeta sobre la  
tabla de dibujar.  
ADVERTENCIA: Este producto contiene partes pequeñas  
que pueden presentar un peligro de asfixiar para niños.  
Siempre utilice supervisión cerca cuando usando  
este aparato cerca de niños o los quienes requieren  
supervisión cerca.  
JB0112-070-INS-LAB-RevB14  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Seguridad en caso de sobrecarga  
s AVISO: No debe exceder más de 30 minutos de operación  
continuo.  
1. Este compresor contiene un dispositivo de protección  
termal. Si el motor comienza a sobrecalentarse, se  
apagará automáticamente. Si esto ocurre, posicione el  
interruptor a la posición OFF y permita que el motor  
se enfrié por 30 minutos antes de recomenzar el  
compresor.  
2. Si el protector apaga el motor frecuentemente, podría  
tener una situación de voltaje inestable.  
3. Si el aparato se apaga y no se enciende, puede ser  
necesario reemplazarlo. Llame a su proveedor  
inmediatamente.  
JB0112-070-INS-LAB-RevB14  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MANTENIMIENTO  
Limpieza de la Carcasa del Compresor  
ADVERTENCIA: Riesgo de electrocución. No remueve  
carcasa externa de este aparato. Todo desensamblaje y  
mantenimiento de este aparato debe ser realizado por un  
técnico de servicio cualificado.  
ADVERTENCIA: Este aparato no necesita aceite. No  
lubrique piezas internas.  
ADVERTENCIA: Desenchufe el aparato antes de limpiar.  
No sumerja bajo agua.  
Frote con un paño húmedo cada semana. No utilice  
detergentes en polvo o abrasivos que pueden dañar la  
carcasa.  
Limpieza de la Taza del Nebulizador  
Todas las piezas del nebulizador desechable, excepto la  
manga, deben ser limpiados después de cada uso. Si su  
médico le da un procedimiento especifica de limpieza, siga  
ese procedimiento.  
ADVERTENCIA: Para prevenir riesgo de infección  
causado por medicamento contaminado, la limpieza del  
nebulizador se recomienda después de cada tratamiento.  
1. Después de cado uso, desensamble la taza  
del nebulizador, el adaptador T y la boquilla  
completamente. Lave todas las piezas en agua tibia con  
jabón y enjuague bien.  
2. A diario, después del paso anterior, remoje los  
componentes del nebulizador en una solución  
consistiendo de una parte agua y una parte vinagre por  
30 minutos, seguido por un enjuague con agua tibia.  
Limpieza de la Tabla de Dibujar  
Limpie la tabla de dibujar con una toalla limpia y con  
humedad seminal. No debe utilizar líquidos, productos de  
limpieza o jabones in cualquier superficie de la tabla.  
JB0112-070-INS-LAB-RevB14  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Instrucciones para el cambio del filtro de aire  
Aviso: Cambie el filtro cada 30 días o cuando el filtro  
cambia color. Filtros adicionales pueden ser comprados en  
Graham-Field.  
1. Remueva la tapa del filtro de aire localizado al lado del  
interruptor ON/OFF.  
2. Remueva el filtro sucio con un objeto punzante.  
3. Reemplace el filtro nuevo.  
4. Reemplace la tapa del filtro.  
s AVISO: No utilice algodón o cualquier material como filtro.  
s AVISO: No lave o limpie el filtro.  
s AVISO: No reutilice el filtro. No opere sin filtro. El  
compresor puede ser dañado por este uso.  
ADVERTENCIA: El kit del nebulizador desechable es para  
uso solamente de una persona.  
Almacenaje  
Mantenga el aparato y los accesorios secos. Evite sol  
directamente.  
JB0112-070-INS-LAB-RevB14  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DETECTANDO PROBLEMAS  
Si su Neb-u-Tyke Neb-a-Doodle Compresor de Nebulizador  
falla, consulte a la guía de Detectando Problemas debajo.  
Si el problema continua, llame a su distribuidor autorizado  
de Graham-Field.  
Problema  
El aparato no  
funciona  
Causa y Solución  
Verifique si el enchufe está conectado correctamente en la toma  
eléctrica apropiada.  
Cuando el aparato ha estado corriendo continuamente por más de 30  
minutos, el protector termal interno puede ser activado para que el  
aparato se enfríe por 30 minutos, antes del próximo uso.  
Nebulización es Verifique que tiene el voltaje eléctrico apropiado.  
débil  
Verifique la manga para bloqueos o escapes de aire en la conexión al  
compresor o la taza de nebulizador, reemplace si es necesario.  
Verifique que la taza del nebulizador está armado bien y no dañado. Si  
hay daño, reemplace si es necesario.  
Verifique si el filtro está sucio, reemplace el filtro.  
JB0112-070-INS-LAB-RevB14  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ESPECIFICACIONES  
Especificación  
Presión máxima del  
compresor  
Descripción  
32.5 PSI  
Flujo máximo  
Tasa de nebulización  
Tamaño de partícula  
Capacidad  
Aproximadamente 12 LPM  
0.33 ml/min  
.5 - 5 microns  
5 ml  
Filtro  
Esponja  
Dimensión  
(largo x anchura x altura)  
10" × 6.5" × 4.2"(255 mm x 166 mm x 108 mm)  
Peso  
4 lb (1860 g)  
Requísito eléctrico  
Corriente  
115VAC/60Hz  
1.2A (tasa)  
Capacidad de fusible  
Cordón eléctrico  
Enchufe  
2.5A 250V  
Blanco, 7.5 ft (90") / 2,286 mm  
De tipo de 2 Aspa  
56.5 dBA  
Nivel de sonido  
Ambiente  
Temperatura Operación: 41°F a 104°F (5°C to 40°C)  
Almacenaje: -40°F to 158°F (-40°C to 70°C)  
Humedad  
Operación: 30% a 95% RH  
Almacenaje: 10% a 95% RH  
JB0112-070-INS-LAB-RevB14  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
GARANTÍA LIMITADA  
AMBITO DE GARANTÍA  
GF Health Products, Inc. (“GF”) garantía al comprador original o arrendatario  
(cual quiera es el “Cliente”) solamente, que va reemplazar o reparar  
componentes, a la decisión solo de GF, cuales son defectos en material o  
calidad utilizado normalmente y con servicio. La garantía es para partes  
solamente y no incluye fuerza laboral o el costo de transporte. Esta garantía  
limitada no es transferible. Todas garantías son condicionales por el uso  
apropiado del producto estrictamente en acuerdo con las instrucciones  
aplicables de GF, incluyendo uso apropiado y mantenimiento. Producto  
próvido a usuarios como réntales deben ser serviciados por el proveedor  
y inspeccionado antes de entrega. Cada usuario debe ser preparado en la  
operación y seguridad de este producto antes de uso. Dentro las reglas  
normales en este documento, el John Bunn JB0112-070 Compresor Nebulizador  
y sus componentes a estar libre de defectos de materiales o mano de obra  
según listado debajo:  
Compresor: cinco años  
Accesorios: seis meses.  
El período de garantía se comienza en la fecha de transporte al Cliente a  
menos que haya una fecha de expiración en el componente en cual la garantía  
se expira en la período de garantía o la fecha de expiración.  
OBTENIENDO SERVICIO DE GARANTÍA  
La garantía limitada solamente aplica a defectos reportados al Distribuidor  
de quien el Cliente compro el producto y quienes ellos en turno notifica al  
equipo de Servicio de Cliente de GF dentro el período de garantía aplicable en  
cuanto será examinado por GF o un representante autorizado para probar el  
producto sobre garantía. Falta de seguir las instrucciones específicas resultara  
en rechazo de la reclamación de garantía. Si no hay Distribuidor, debes llamar  
a GF directamente llamando 678-291-3207, mandando fax a 770-368-2386 o  
por email a cs@grahamfield.com. Direcciones específicos se van a dar por el  
Representante de Servicio De Clientes.  
EXCLUSIONES  
La garantía no cubre ni GF será responsable de lo siguiente:  
1) Defectos, daño u otras condiciones causadas por mal uso, abuso,  
negligencia, alteración, accidente, daño de transporte o falta de buscar y  
obtener reparo o repuesto en manera puntual;  
2) Productos con los números seriales quitados o desfigurados;  
3) Productos no instalados, utilizados or mantenidos correctamente como  
requerido en los manuales oficiales del Producto; y  
4) Cargos de Labor o transporte incurridos en el regreso o instalación de  
partes de reemplace;  
5) Productos considerados ser consumibles como dicho en este documento;  
6) Asesorías o partes no próvidos por GF;  
7) Cargas por otras personas por ajustamientos, reparaciones, partes de  
reemplace, instalación u otro trabajo hecho en conexión con este Producto  
no autorizado en escrito en avanza por GF;  
8) Cargas y gastos de mantenimiento y limpieza regular; y  
9) Representaciones y garantías hechos por otras personas o entidades no  
GF.  
JB0112-070-INS-LAB-RevB14  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
GARANTÍA ENTERO, REMEDIO EXCLUSIVO Y DESCARGO DE  
DAÑOS CONSIGUIENTE  
ESTA GARANTIA ES LA UNICA GARANTIA DE GF Y ES EN VEZ DE TODAS  
OTRAS GARANTIAS, EXPRESIDAS O IMPLICITADAS. GF NO HACE GARANTIAS  
ENTENTIDOS DE CUAL QUIER MANERA INCLUYENDO GARANTIAS  
ENTENDIDOS DE COMERCIALIZACION O IDONEIDAD PARA UN PROPOSITO  
PARTICULAR. SI UN MODELO Y MUESTRA SE LE ENSENO A UN CLIENTE,  
TAL MODELO O MUESTRA FUE UTILIZADO SOLAMENTE PARA ILUSTRAR  
EL TIPO GENERAL Y CALIDAD DEL PRODUCTO Y NO PARA REPRESENTAR  
QUE EL PRODUCTO SE CONFORME CON ESE MODELO Y MUESTRA EN  
TODOS RESPETOS. TODA RESPONSABILIDAD DE GF POR CUAL QUIER  
PRODUCTO Y SERVICIO PROVIDO ES LIMITADA AL COSTO DEL PRODUCTO  
EN LA RECLAMACION. EN NO EVENTO EN CONTRACTO, INDEMNIZACION,  
GARANTIA, NEGLIGENCIA, RESPONSABILIDAD ESTRICTA O OTRO QUE GF  
SERA RESPONSABLE POR CUAL QUIER DANO DIRECTO, ESPECIAL, INDIRECTO,  
INCIDENTAL, EJEMPLAR O CONSIGUIENTES INCLUYENDO PERO NO LIMITADO  
A: DANOS FOR PERDIDA DE BENEFICIO O GANANCIA, PERDIDA DE USO,  
INACTIVO, O SALARIOS DE EMPLEADOS O TRABAJADORES CONTRACTORES,  
PAGOS O BENEFICIOS.  
Esta garantía te da derechos legales específicos. Podrás tener derechos  
adicionales que varían estado por estado.  
JB0112-070-INS-LAB-RevB14  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Fabricado para:  
GF Health Products, Inc.  
2935 Northeast Parkway  
Atlanta, Georgia 30360 USA  
Telephone: 770-368-4700  
Fax: 770-368-2386  
Fabricado en China  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Grundig Flat Panel Television ROM 26 CLE 8100 BG User Manual
Handspring PDAs Smartphones Visor Prism User Manual
Harbor Freight Tools Drill 94434 User Manual
Hasbro Games GI Joe Voice FX Duke User Manual
Hotpoint Washer WMEF 742 User Manual
HP Hewlett Packard Computer Accessories BC767A User Manual
HP Hewlett Packard Network Router SR2122 2 User Manual
Husqvarna Cultivator CA 150 User Manual
Ikelite Camera Accessories A1000 IS User Manual
IMC Networks Network Router IE IMCV User Manual