1 INTRODUCTION  
Congratulations on your purchase of the Lumex LF2020 Easy Lift Sit-to-Stand (STS) /  
LF2090 Bariatric Easy Lift Sit-to-Stand (STS). The following pages will provide you with important  
safety and operating instructions on the use of patient lifts, slings, and accessories, as well as  
maintenance and warranty information. Read this manual carefully before operating your patient  
lift and refer to it as often as needed. Consult your authorized distributor and/or healthcare  
professional with any questions or concerns regarding safe and effective techniques for operating  
your patient lift.  
DO NOT attempt any transfer without prior approval of the patient’s healthcare provider. With  
their assistance, select the sling that best serves the needs, abilities, comfort and safety of the  
person being lifted. It is important that you use correct slings adapted to the body shape and  
weight and ability of the patient and the specific type of transfer needed.  
Upon receipt of the patient lift, and prior to each use, inspect it closely to ensure that nothing is  
damaged, there are no loose or broken parts, that all patient lift parts are in the proper place, etc.  
Immediately replace any worn or broken components. Your patient lift should receive maintenance  
on a regular schedule and should be inspected daily for proper operation. Contact your authorized  
Graham-Field distributor for service and repairs.  
Before lifting anyone, thoroughly read the instructions in this manual. Ideally, observe a team of  
trained experts performing the lifting procedures. The operator should then practice the entire  
lifting procedure several times with proper supervision and with a capable individual acting as  
patient. It is extremely important to know how a patient will feel in the patient lift. We suggest that  
the operator try all the various lifting slings and equipment until the operator is confident with  
how the patient lift operates. The lifting procedures should be explained to the patient before the  
actual lifting. Remember that safety requires the constant attention of the lift occupant and the  
operator. Use extreme care and common sense when operating a patient lift.  
This guide covers the use of the LF2020 Easy Lift STS / LF2090 Bariatric Easy Lift STS. Keep in mind  
that the basic safety procedures included in this manual are to be used as a guide only. You may find it  
necessary to develop your own unique methods for safely utilizing the patient lift. Again, consult your  
healthcare professionals for their recommendations and never hesitate to ask for their assistance.  
Info: Before attempting to assemble the patient lift, refer to the section titled “ASSEMBLY  
INSTRUCTIONS” contained elsewhere in this manual. Contact your authorized  
Graham-Field distributor if additional assistance is needed.  
Info: In this manual, the person being lifted is referred to as the “patient” or “occupant”  
and the person operating the patient lift is called the “operator” or “attendant”.  
Intended use  
The Lumex LF2020 Easy Lift STS / LF2090 Bariatric Easy Lift STS is intended to aid in the transfer  
of an individual who is unable to independently transfer between bed, chair, bathtub, wheelchair,  
and/or commode.  
WARNING: The LF2020 Easy Lift STS / LF2090 Bariatric Easy Lift STS is designed for  
transfer only (to and from bed, chair, bathtub, toilet, wheelchair, commode etc.). This  
Patient Lift is not intended to be used for transporting or moving a patient from one  
location to another.  
WARNING: The LF2020 Easy Lift STS / LF2090 Bariatric Easy Lift STS is designed for  
use by individuals who can support the majority of their own weight. Special care must  
be taken with patients who cannot provide assistance while being lifted. (i.e. such as  
patients who are comatose, spastic, agitated or otherwise severely disabled).  
LF2020-INS-LAB-RevC12  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
2 SAFETY PRECAUTIONS  
IMPORTANT: Before using patient lift, please read and adhere to the following safety  
precautions and warnings. Failure to do so could result in serious personal injury or  
damage to your patient lift.  
Always consult your healthcare professional to determine safe methods most suitable for your  
individual abilities. Protect yourself, your attendant and patient lift by having it serviced regularly.  
If you experience any malfunction, contact your authorized Graham-Field distributor immediately,  
as a hazardous condition could result, causing personal injury or damage to your patient lift.  
Periodic inspection, adjustment and replacement of worn parts are necessary to provide years of  
excellent service. Refer to CARE AND MAINTENANCE section of this manual.  
Maintenance MUST be performed by qualified personnel ONLY.  
Significance of safety statements  
Please note the following special statements, used throughout this manual, and their significance:  
WARNING: Indicates a potential hazard situation or unsafe practice that, if not avoided,  
could result in death or serious personal injury.  
CAUTION: Indicates a potential hazard situation or unsafe practice that, if not avoided,  
could result in minor or moderate personal injury.  
s NOTICE: Indicates a potential hazard situation or unsafe practice that, if not avoided,  
could result in product or property damage.  
Info: Provides application recommendations or other useful information to ensure that you  
get the most from your product.  
WARNINGS  
WARNING: Important! Read and understand these instructions before assembling or  
using the Lumex LF2020 Easy Lift STS / LF2090 Bariatric Easy Lift STS. If you do not  
understand any part of these warnings, cautions or instructions, contact a healthcare  
professional for direction in the use of this product. If the Lumex LF2020 Easy Lift STS /  
LF2090 Bariatric Easy Lift STS is not properly assembled, personal injury and damage to  
the LF2020 / LF2090 could result.  
WARNING: If components are damaged or missing, contact your Graham-Field distributor  
immediately. DO NOT use substitute parts. Use only Lumex replacement parts. The use  
of non-Lumex replacement parts could cause personal injury, property damage, and void  
the warranty.  
WARNING: Unauthorized modification of your patient lift could cause personal injury,  
property damage, and void the warranty.  
WARNING: The maximum weight capacity of this device is:  
LF2020 Easy Lift STS: 400 lb, EVENLY DISTRIBUTED  
LF2090 Bariatric Easy Lift STS: 600 lb, EVENLY DISTRIBUTED  
DO NOT exceed the maximum weight capacity.  
WARNING: GF Health Products, Inc. assumes no responsibility for any damage or injury  
caused by improper assembly or use of this product.  
WARNING: Check all parts for shipping damage before using. In case of damage, DO NOT  
USE the equipment. Contact the carrier or your authorized Graham-Field distributor for  
further instructions.  
WARNING: Patient lift may tip over if used incorrectly. Read and adhere to the operating  
instructions prior to lifting anyone.  
LF2020-INS-LAB-RevC12  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
WARNING: GF Health Products, Inc. strongly recommends that two caregivers take part  
in the lifting process.  
WARNING: When transferring a patient, always keep the patient centered over the base.  
WARNING: Ensure that lifting sling loops are correctly attached to the hooks to prevent  
the patient from sliding or falling out of the sling, which could result in personal injury.  
Never use the patient lift to lift or transfer anything other than a person.  
WARNING: Do not put anything (e.g. cushion, pad, etc.) between the user and the sling.  
This could cause user to slide out of the sling and result in personal injury.  
WARNING: Do not lock the brakes or block the wheels when lifting. The casters must be  
FREE to roll to allow the patient lift to stabilize itself when the patient is initially lifted  
from a chair, bed, or any stationary object.  
WARNING: Do not roll casters over any object while the user is in the sling.  
WARNING: Do not attempt to maneuver the lift by pushing on the mast, boom, actuator,  
or patient. Always maneuver the lift with the handle.  
WARNING: During lifting or lowering, whenever possible, always keep the patient lift legs  
in the maximum open position.  
WARNING: To facilitate movement, close patient lift legs before moving the lift.  
WARNING: Replace any worn or broken parts immediately! Torn, cut, frayed, or broken  
slings can fail, resulting in serious personal injury. Use only slings that are in good  
condition.  
WARNING: Use extreme care, caution, and common sense when utilizing a patient lift.  
Special attention must be given to patients who are disoriented and cannot cooperate  
while being lifted, such as comatose, agitated, spastic, or mentally confused persons.  
Consult their healthcare professional for assistance in lifting these types of patients.  
WARNING: The electronics and actuator contain no serviceable components. If service  
is required, the unit must be returned to the factory for repair. DO NOT attempt to  
open the electronics or actuator or obtain local service; this will void the warranty and  
could result in damage to the unit. Consult your Graham-Field Distributor for further  
information.  
WARNING: GF Health Products, Inc. specifically disclaims responsibility for any bodily  
injury or property damage which may occur during any use which does not comply with  
federal, state or local laws or ordinances.  
LF2020-INS-LAB-RevC12  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
3 FEATURES  
EASY LIFT SIT-TO-STAND FEATURES  
Pendant  
Actuator  
Lifting Boom  
Knee Pad  
Control Box  
Mast  
Footrest  
Brake  
Base  
CONTROL BOX FEATURES  
RESET Button  
Battery Testing  
Battery Charger Plug-In  
Pendant Plug-In  
Actuator Plug-In  
LF2020-INS-LAB-RevC12  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
4 HANDLING PROCEDURES  
SHIPPING AND TRANSPORTATION INSTRUCTIONS  
If the patient lift is to be reshipped by common carrier, it should be packed in the same carton in  
which it was received.  
Unpacking  
WARNING: The lift is heavy. To avoid personal injury, DO NOT attempt to remove the lift  
from the box without assistance.  
1. Check for any obvious damage to the carton or its contents. If damage is evident, notify the  
carrier or your Graham-Field distributor.  
2. Remove all loose packing from the carton.  
3. Carefully remove all the components from the carton.  
Info: Unless the patient lift is to be used immediately, retain boxes, containers and packing  
material for use in storing until use of patient lift is required.  
Inspection  
1. Examine the exterior of the patient lift for nicks, dents, scratches or other damage.  
2. Inspect all components.  
Storage  
1. Store the repackaged patient lift in a dry area.  
2. DO NOT place other objects on top of the repackaged patient lift.  
LF2020-INS-LAB-RevC12  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
5 ASSEMBLY INSTRUCTIONS  
WARNING: The lift is heavy. To avoid personal injury, DO NOT attempt to assemble the  
lift without assistance.  
1. Remove the nuts and bolts from top and bottom of mast.  
2. With one hand on the mast and another on the boom, pull the mast to an upright position.  
3. Reinstall the bolts in the holes at bottom of mast and hand tighten them.  
4. Attach boom to mast and hand tighten bolt and nut.  
5. Attach the L-shaped arms to the back of the knee pad.  
6. Attach knee pad assembly to the mast.  
7. Place the control box in the bracket.  
8. Insert the actuator plug into the control box.  
9. Insert the pendant plug into the control box.  
10. Tighten all nuts.  
WARNING: Before using Patient Lift, ensure that lift is assembled as described, that all  
attaching hardware is securely tightened, and that all lift components are secure.  
Info: Before using the lift, charge the batteries for ten to twelve hours (see instructions on  
following page).  
LF2020-INS-LAB-RevC12  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
CHARGING THE BATTERIES  
Charge the batteries after assembly.  
1. Ensure the control box power switch is ON (i.e., the red button is up).  
2. Insert the charger plug into the battery box charging socket (the top slot).  
3. Insert the other charger plug into the power supply.  
4. All LED indicator lights should be ON during charging.  
5. When one green LED indicator light illuminates, the batteries require approximately two to  
three hours to be fully charged.  
6. When only the red LED indicator light illuminates, the batteries require approximately seven to  
nine hours to be fully charged.  
s NOTICE: Do not charge the batteries for more than twelve hours.  
7. Unplug the charger FIRST before using the lift.  
Info: The lift will not operate while the batteries are charging.  
The lift will not operate while the red reset button is down.  
8. Replace the batteries when frequent charging is required.  
Important Charging Information  
Push lift to an appropriate location and charge the batteries with the charger provided.  
s NOTICE: Avoid unplugging the pendant and actuator from the control box. Frequent  
plugging and unplugging of the pendant and actuator to and from the control box may  
damage the control box.  
CHECKING BATTERY CAPACITY  
Info: To check remaining battery capacity, press the battery indicator (blue circle with  
battery symbol) while the lift is not in motion. Remaining battery capacity is indicated by  
LED indicator lights and explained in the following table.  
Red  
ON  
Amber  
ON  
Green  
ON  
Green  
ON  
Green  
ON  
Status  
Fully charged  
ON  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
Needs charge  
ON  
ON/OFF  
OFF  
OFF  
OFF  
Charge immediately—DO NOT use lift  
Bad batteries or bad connection  
OFF  
ALARM BUZZERS  
The control box has an alarm buzzer that provides information on the status of the batteries and  
the lift. To stop the buzzer, push down the RED RESET button or press the battery indicator.  
Buzzer type  
Status  
Note  
2 beeps per second  
3 beeps per second  
6 beeps per second  
3 beeps every other second  
3 long beeps  
Low battery (red/amber lights illuminate) Charge batteries immediately  
Low battery (red light illuminates)  
Very low battery (no lights illuminate)  
Bad battery (no lights illuminate)  
Charge batteries immediately  
Charge batteries immediately  
Replace batteries immediately  
Maximum load capacity exceeded  
Overloaded. Batteries are charged but  
lift does not lift  
LF2020-INS-LAB-RevC12  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
6 OPERATING INSTRUCTIONS  
WARNING: During lifting and lowering, whenever possible, always keep the base legs of  
the lift in the widest position.  
WARNING: Use only Lumex slings specially designed for the LF2020 Easy Lift STS /  
LF2090 Bariatric Easy Lift STS.  
WARNING: DO NOT use torn, cut, frayed or broken slings as injury could result.  
WARNING: Do not put anything (e.g. cushion, pad, etc.) between the user and the sling.  
This may cause user to slide out of the sling and could cause injury.  
WARNING: GF Health Products, Inc. strongly recommends that two caregivers take part  
in the lifting process.  
Info: Instructional videos that review the application of several sling styles and lifting  
Info: While transferring a patient, the patient lift legs can be in either open or closed  
position.  
Preparation before lifting  
1. Turn on the power by turning the RED RESET BUTTON clockwise.  
2. Press the pendant UP or DOWN button once.  
3. After the battery indicator lights de-illuminate, push the pendant UP button and DOWN button  
to ensure the lift is operating correctly.  
4. Position the lift base around or under the patient.  
5. Widen the base.  
Fitting Lumex Sit-to-Stand Sling  
WARNING: The Lumex Sit-to-Stand sling is not suitable for patients who have involuntary  
movements, or patients with limited postural control.  
WARNING: Ensure the sling you are using has adequate weight capacity for the person  
you are lifting.  
1. Position the patient in a sitting position.  
2. Slide the sling down patient’s back to lumbar position.  
3. Draw the shoulder straps to the front of the patient close to the chest.  
4. Draw the waist belt around patient’s waist and press hook and loop sections together to fasten.  
5. Place shoulder straps inside the positioning loop.  
6. Attach the shoulder straps to the hooks.  
LF2020-INS-LAB-RevC12  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
LIFTING THE PATIENT  
WARNING: Do not attempt to transfer a patient without prior approval of the patient’s  
healthcare professional and without having read the instructions and practiced using  
the patient lift.  
WARNING: Ensure the floor area is clear of any obstacle that could cause a caster to  
stop and possibly tip the patient lift.  
Lift and transfer from bed  
WARNING: Do not lock or block the patient lift casters when lifting. The casters must be  
free to roll so that the patient lift can stabilize as the patient is lifted from the bed.  
WARNING: To ensure stability while lifting or lowering a patient, the patient lift legs  
should be in the maximum open position.  
1. Fit sling as described in “Fitting Lumex Sit-To-Stand Sling”.  
2. Push lift towards patient. Open the base of the lift. Apply the brakes on both rear casters.  
3. Position patient’s feet on the foot platform and knees against the knee pad.  
4. Attach the sling straps to the hooks.  
5. Have the patient’s hands holding the handles. For patients who cannot hold the handles, have  
them hold their arms around the chest.  
6. Press the “UP” button on the hand pendant.  
7. Before the patient’s body is lifted from the bed, stop and make sure the sling is secured and  
patient’s knees are against the knee pad.  
8. The patient should be comfortable with the pressure under the arms. If not, adjust the sling  
and try another loop option to release pressure.  
9. Press the “UP” button until the patient’s body has completely left the bed.  
10. Transfer to another object can be done at this position without the patient attending a full  
standing position.  
11. Release the brakes, close the base, and pull the lift away from the bed.  
12. Lower the patient to the object intended.  
13. To lift patient in a standing position, continue to lift until the patient’s knees are locked in a  
standing position.  
14. At the standing position, patient’s knees may move away from the knee pad.  
15. Close the base, and pull the lift away from the bed.  
16. Lower the patient to the object intended.  
17. Reverse the above procedures when lowering the patient to the bed.  
LF2020-INS-LAB-RevC12  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Lift and transfer from chair  
WARNING: GF Health Products, Inc. recommends that two attendants be used when  
transferring a patient to and from a wheelchair.  
WARNING: Before transfer, ensure wheelchair wheel locks are in locked position.  
Wheelchair wheel locks must be in LOCKED POSITION before lowering the patient into  
the wheelchair, or unexpected wheelchair movement could result, which may result in  
serious injury to both the patient and the attendants.  
1. Fit sling as described in “Fitting Lumex Sit-To-Stand Sling”.  
2. Push lift towards patient. Open the base of the lift to go around the chair. Apply the brakes on  
both rear casters.  
3. Position patient’s feet on the foot platform and knees against the knee pad.  
4. Attached the sling straps to the hooks.  
5. Have the patient’s hands holding the handles. For patients who cannot hold the handles, have  
them hold their arms around the chest.  
6. Press the “UP” button on the hand control.  
7. Before the patient’s body is lifted from the chair, stop and make sure the sling is secured and  
patient’s knees are against the knee pad.  
8. The patient should be comfortable with the pressure under the arms. If not, adjust the sling  
and try another loop option to release pressure.  
9. Press the “UP” button until the patient’s body has completely left the chair.  
10. Transfer to another object can be done at this position without the patient attending a full  
standing position.  
11. Release the brakes, close the base, and pull the lift away from the chair.  
12. Lower the patient to the object intended.  
13. To lift patient in a standing position, continue to lift until the patient’s knees are locked in a  
standing position.  
14. At the standing position, patient’s knees may move away from the knee pad.  
15. Release the brakes, close the base, and pull the lift away from the chair.  
16. Lower the patient to the object intended.  
17. Reverse the above procedures when lowering the patient to the chair.  
LF2020-INS-LAB-RevC12  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7 CARE AND MAINTENANCE  
Proper care and maintenance are essential to keeping your Lumex LF2020 Easy Lift STS / LF2090  
Bariatric Easy Lift STS in a safe operating condition. In addition to inspecting the unit before  
each use, periodic maintenance checks should be done. We further recommend that this unit be  
serviced at least once annually by an authorized Graham-Field distributor.  
WARNING: It is extremely important that the patient lift be inspected before each use.  
Ensure that all hardware and accessories are secure and that the actuator is functioning  
properly. Failure to do so could result in patient / attendant injury or damage to your patient  
lift. Torn, cut, frayed or broken slings can fail, resulting in serious injury. Only use slings in  
good condition. Inspect before each use. Destroy and discard old worn and unusable slings.  
WARNING: Service and repair of the LF2020 Easy Lift STS / LF2090 Bariatric Easy Lift STS  
should be performed only by an authorized Graham-Field distributor. GF Health Products, Inc.  
is not responsible for any consequence resulting from any unauthorized service or repair.  
WARNING: Unauthorized modification of the patient lift or the use of non-Lumex  
replacement parts may change the structure of the lift and could create a hazardous  
condition, which may result in serious injury and will void the warranty.  
WARNING: The electronics and actuator contain no serviceable components. DO NOT  
open the electronics or actuator; this will void the warranty and may result in damage to  
the unit. Consult your authorized Graham-Field distributor for further information.  
When you believe a component or part is not functioning properly, immediately contact your  
authorized Graham-Field distributor, as a potentially hazardous condition could exist.  
BEFORE EACH USE  
Before each use of the patient lift, ensure that:  
• All nuts and bolts are tight  
• The lift moves freely (with caster brakes off)  
• Rear caster brakes operate properly  
• Base adjustment mechanism operates easily  
• All necessary items (i.e. slings, wheelchairs, etc.) are accessible and ready for use  
• Battery capacity is adequate  
AT LEAST ONCE A MONTH  
The lift should be thoroughly inspected by a person qualified to recognize any signs of wear, and  
looseness of bolts or parts. Replace any worn parts immediately.  
LUBRICATION  
When the lift is serviced, and every month thereafter, place a drop of oil on the following points:  
• The point where mast and boom connect  
• Caster axles  
• The point where actuator and boom connect  
CLEANING  
Regular cleaning is recommended every three months; clean the lift more often as needed. A soft  
cloth, dampened with water and a mild NON-ABRASIVE detergent (household cleaner, soapy water, or  
hospital grade disinfectant) is all that is needed to clean your patient lift. Automobile wax or furniture  
polish will help maintain the finish over a long period of time.  
s NOTICE: DO NOT wash patient lift under water pressure or steam clean.  
CARE OF SLINGS  
Lumex slings are washable at 150°F or less The slings can be air dried or dried by using a dryer on  
LOW heat.  
s NOTICE: DO NOT bleach slings!  
LF2020-INS-LAB-RevC12  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MAINTENANCE SCHEDULE  
Info: Only qualified persons should service and repair your Lumex LF2020 Easy Lift STS /  
LF2090 Bariatric Easy Lift STS. Regular maintenance of your patient lift is necessary to  
ensure continuing proper and safe operation. Read and observe the following recommended  
maintenance schedule:  
Item  
Inspect  
initially  
Inspect / adjust  
daily  
monthly every 6  
months  
Base, Casters, and Foot Paddle  
Ensure that base is level (all four wheels touch the floor)  
x
x
x
x
x
x
x
x
x
Ensure that bolts and nuts are tight  
x
x
Ensure that casters swivel and roll freely  
Apply a light grease to caster ball bearings  
Check rubber parts of casters for deflection  
Check welding joints for rust and cracks  
Ensure that base opens and closes smoothly  
Ensure that base locks securely in three positions  
Ensure that base locking knob is in place and operating properly  
Inspect all base hardware for wear  
x
x
x
x
x
x
x
x
x
x
x
x
x
Mast  
Ensure that mast is fully engaged and locked into mast sleeve  
Inspect mast for bends or deflections  
Inspect all mast hardware for wear  
x
x
x
x
x
Boom  
Inspect boom for bends or deflections  
Ensure that boom is centered between the base legs  
Inspect all boom hardware for wear  
x
x
x
x
x
x
x
x
x
Inspect sling hooks for wear or deflections  
Check connections between boom and mast for improper  
connection, looseness, or wear  
x
Slings and Sling Hardware  
Check slings and straps for wear and damage; discard if worn  
Inspect metal/plastic parts for wear or damage  
Lubrication with Light Oil  
x
x
x
x
Lubricate all pivot points  
x
x
Lubricate top and bottom of actuator mounting  
Cleaning  
Clean with mild non-abrasive detergent  
x
Actuator and Electronics  
Ensure that batteries are charged  
x
x
x
x
x
Inspect for proper up / down operation  
Ensure that mounting hardware is tight  
Inspect mounting hardware for wear  
Ensure that control box is firmly affixed to the mast  
Ensure that the actuator connecting cable is tight  
x
x
x
x
x
x
LF2020-INS-LAB-RevC12  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
8 TROUBLESHOOTING  
The following list of encountered problems and their solutions will assist you in determining what  
may be causing your Lumex lift not to function as designed. If you have a problem occurring which  
is not listed below, please contact your distributor or Graham-Field Technical Support for help.  
Do not attempt to repair components or parts on your lift, as this may invalidate your warranty or  
cause further problems that may result in patient injury. Stop using your lift immediately if it is not  
functioning correctly or any warning beeps are heard.  
SYMPTOM  
POSSIBLE CAUSE  
ACTION  
The actuator is stalled and a  
clicking sound is audible  
Actuator plug is not seated  
properly into control box  
Firmly plug actuator plug into  
control box  
Actuator is defective or at end of  
its life cycle  
Replace actuator if control box is  
good  
Control box is defective  
Replace control box if bad; replace  
control box if pendant is good;  
replace pendant if bad  
The actuator will either go up or  
down, but not both  
Hand pendant or control box  
defective  
Replace control box if pendant is  
good  
Replace pendant if it is bad  
The actuator makes a grinding  
sound while lifting, but works fine  
without a load  
The internal gear is stripped, likely Stop using the lift immediately!  
due to overloading  
Repair or replace the actuator  
The actuator stops and starts  
during lifting or lowering  
Bad batteries  
Check battery indicator; confirm  
if lights drop quickly to red light;  
replace batteries  
The lift will not operate even though Battery charger still plugged in  
Unplug battery charger  
Plug hand pendant firmly into  
control box, or replace pendant  
battery indicator shows charge  
Poor connection between control  
box and pendant, or defective  
pendant  
Poor connection between actuator control box  
and control box  
Plug actuator cord firmly into  
The lift will not operate and battery Control box may be in OFF position Turn the red emergency stop button  
indicator has no lights illuminated  
until it pops up to the ON position  
Check inside control box to ensure  
batteries are connected  
Use charger to charge batteries,  
ensuring the red emergency stop  
button is in ON or UP position  
Internally, batteries may be loose  
from their connections  
Batteries are in need of being  
charged  
Batteries are dead and won’t hold a  
new charge  
Replace the batteries  
During charging, the battery  
indicator is not illuminated and  
won’t charge  
The red emergency stop button is  
in OFF or DOWN position  
The battery charger is defective or Inspect the battery charger for  
at end of its life cycle damage and replace if required  
Turn the red emergency stop button  
until it pops up to the ON position  
The battery indicator indicates need The batteries are at end of life cycle Replace the batteries  
for frequent charging and/or lift  
loses power  
The lift will not operate, and there  
is no clicking sound or light when  
pendant is pressed  
The pendant is loose/defective or  
at end of its life cycle  
Check battery indicator; replace  
pendant if battery indicator shows  
full charge  
WARNING: If you experience a problem with your lift and are unable to solve it yourself,  
contact your Graham-Field provider.  
LF2020-INS-LAB-RevC12  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
9 SPECIFICATIONS  
Info: All dimensions are given in inches unless otherwise specified.  
Base width  
Open: 43"  
Closed: 26"  
6"  
Base height clearance  
Overall base length  
50"  
Lifting height range  
Info: As measured from sling hooks.  
Minimum: 27"  
Maximum: 71"  
Range: 35"  
50"  
Mast height  
Maximum weight capacity  
LF2020 Easy Lift STS: 400 lb, EVENLY DISTRIBUTED  
LF2090 Bariatric Easy Lift STS: 600 lb, EVENLY DISTRIBUTED  
Rear locking caster size  
Front caster size  
4" diameter  
4” diameter  
Lifting mechanism  
Battery charger  
24 DC actuator  
AC 110V / 220V to DC 24V 1 amp  
LF2020-INS-LAB-RevC12  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
10 LIMITED WARRANTY  
GF Health Products Inc. (“Graham-Field”) warrants this product to be free from manufacturing defects  
in material and workmanship for its period of warranty that is in accordance with industry standards.  
This warranty is extended only to the original purchaser/consumer or dealer/non-consumer of this  
new product and to no other purchaser or transferee.  
GF Health Products, Inc. warrants the Lumex LF2020 Easy Lift Sit-to-Stand / LF2090 Bariatric Easy Lift  
Sit-to-Stand and its components to be free from defects in workmanship and materials as listed below:  
Lift frame and spreader bar:............................................................three years  
Actuator: ............................................................................................two years  
Parts, including casters, control box, pendant, charger:.............two years  
Batteries:............................................................................................one year  
The Warranty period for the consumer commences on the first date a product is delivered to consumer  
by seller/dealer. If the product is rented or leased, the warranty period commences on the invoice  
date from GF Health Products, Inc. A copy of the invoice showing date of purchase must be provided  
when submitting warranty claims. When proof of purchase date is not provided, warranty coverage  
shall commence upon GF Health Products, Inc.’s invoice date to the dealer/purchaser.  
If within the warranty period, the product or component part is proven to GF Health Products, Inc.’s  
satisfaction to be defective, GF Health Products, Inc. shall provide, at its option, one of the following:  
(1) repair or replacement of any defective or nonconforming part or product or (2) a credit and/or  
refund of the original selling price. GF HEALTH PRODUCTS, INC.’S SOLE OBLIGATION AND YOUR  
EXCLUSIVE REMEDY UNDER THIS WARRANTY SHALL BE LIMITED TO SUCH REPAIR, REPLACEMENT,  
CREDIT AND/OR REFUND. This warranty does not include any labor charges incurred in replacement  
part(s) installation or any associated freight or shipping charges to the manufacturer.  
For warranty service, please contact the authorized distributor from whom you acquired your GF  
Health Products, Inc. product. Upon receiving notice of an alleged defect in a product, GF Health  
Products, Inc. will issue a return authorization. The defective product or part(s) must then be returned,  
at the purchaser’s cost, for warranty inspection using the serial number as identification (or, if the  
product is not serialized, lot number and date code) within thirty (30) days of return authorization  
issue date. In the event you do not receive satisfactory warranty service, please contact GF Health  
Products, Inc. at the address on the following page. DO NOT return products to our factory without  
prior authorization.  
LIMITATIONS AND EXCLUSIONS: The foregoing warranty shall not apply to serial numbered products  
if the serial number has been removed or defaced. Products subjected to negligence, abuse, misuse,  
improper operation, improper maintenance, improper cleaning, improper storage, or damages beyond  
GF Health Products, Inc.’s control are not covered by this warranty, and that evaluation shall be solely  
determined by GF Health Products, Inc. This warranty shall not apply to problems arising from normal  
wear and tear or failure to follow instructions. The warranty shall also not apply to products modified  
without GF Health Products, Inc.’s express written consent; nor shall it apply if parts not manufactured  
by GF Health Products, Inc., or if parts not complying with original equipment specifications are added  
to GF Health Products, Inc. products, or if the product or part is serviced by an entity not authorized  
by GF Health Products, Inc.  
LF2020-INS-LAB-RevC12  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
THE FOREGOING WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS  
WARRANTIES AND IMPLIED WARRANTIES, INCLUDING BUT NOT LIMITED TO THE  
IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR  
PURPOSE, AND SHALL NOT EXTEND BEYOND THE DURATION OF THE EXPRESS  
WARRANTY PROVIDED HEREIN, AND THE REMEDY FOR VIOLATIONS OF ANY IMPLIED  
WARRANTY SHALL BE LIMITED TO THE REPAIR, REPLACEMENT, CREDIT AND/OR  
REFUND OF THE DEFECTIVE PRODUCT OR PART PURSUANT TO THE TERMS CONTAINED  
HEREIN. GF HEALTH PRODUCTS, INC. SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL  
OR INCIDENTAL DAMAGES WHATSOEVER.  
This warranty gives you specific legal rights and you may also have other legal rights which vary  
from state to state (province to province). Some states (provinces) do not allow the exclusion or  
limitation of incidental or consequential damage, or limitation on how long an implied warranty lasts,  
so the above exclusion and limitations may not apply to you.  
The warranties contained herein contain all the representations and warranties with respect to the  
subject matter of this document, and supersede all prior negotiations, agreements and understandings  
with respect thereto. The recipient of this document hereby acknowledges and represents that it  
has not relied on any representation, assertion, guarantee, warranty, collateral contract or other  
assurance, except those set out in this document.  
GF Health Products, Inc. (“Graham-Field”)  
2935 Northeast Parkway  
Atlanta, GA 30360  
Tel 770-368-4700  
Fax 770-368-2386  
LF2020-INS-LAB-RevC12  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
11 INDEX  
P
A
Preparation before lifting 10  
Alarm buzzers, significance 9  
Assembly instructions 8  
S
Safety precautions 4  
Safety statements, significance of 4  
Shipping and transportation instructions 7  
Sit-to-Stand Sling, fitting 10  
Specifications 16  
B
Batteries, charging 9  
Battery capacity, checking 9  
Battery capacity LED indicator lights, significance 9  
Before each use 13  
Storage 7  
C
T
Care and maintenance 13  
Troubleshooting 15  
Care of slings 13  
CAUTION statement, significance 4  
Cleaning 13  
U
Unpacking 7  
Control box features 6  
V
E
Easy Lift Sit-to-Stand features 6  
W
F
Warnings 4  
Features 6  
WARNING statement, significance 4  
Warranty, limited 17  
H
Handling Procedures 7  
I
Info statement, significance 4  
Inspection 7  
Intended use 3  
Intended use contraindication 3  
Introduction 3  
L
Lift and transfer from bed 11  
Lift and transfer from chair 12  
Lifting the patient 11  
Lubrication 13  
M
Maintenance schedule 14  
Maximum weight capacity 4  
N
NOTICE statement, significance 4  
O
Operating Instructions 10  
LF2020-INS-LAB-RevC12  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
GF Health Products, Inc.  
2935 Northeast Parkway  
Atlanta, Georgia 30360 USA  
tel: 770-368-4700  
fax: 770-368-2368  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Graco Baby Swing PD247880A 4 13 User Manual
Green CleanUSA Switch KV P00801 User Manual
Hamilton Beach Blender HBH450 User Manual
Hamilton Beach Hot Beverage Maker 40893 User Manual
Harbor Freight Tools Landscape Lighting 95059 User Manual
Harman Kardon Stereo System MAS 101 User Manual
Health O Meter Scale HDL150 05 User Manual
Hypertec Carrying Case 6101HY User Manual
Hypertec Carrying Case TSV12WFV2HY User Manual
IBM Laptop G7617 User Manual