SAFETY — PRECAUTIONS FOR USE  
WARNING: Indicates a potential hazard situation or  
unsafe practice that, if not avoided, could result in death  
or serious injury. WARNING statements follow:  
Before use, carefully read the manual.  
OXYCHECK  
FINGERTIP  
The pulse oximeter has no alarms. Do not use the pulse  
oximeter in situations where alarms are required. It is not  
for continuous monitoring.  
The pulse oximeter is intended only as an adjunct in user  
assessment. It must be used in conjunction with other  
methods of assessing clinical signs and symptoms.  
PULSE OXIMETER  
MODEL JB02017  
OPERATOR MANUAL  
CAUTION: Indicates a potential hazard or unsafe prac-  
tice that, if not avoided, could result in moderate or  
minor personal injury. CAUTION statements follow:  
GENERAL DESCRIPTION  
The John Bunn® JB02017 OxyCheck Fingertip Pulse Oximeter  
provides a simple way to spot-check users by combining the  
sensor and monitor into one integrated, compact, easy to use  
device. The oximeter measures pulse oxygen saturation (SpO2 )  
value, pulse rate value, and pulse strength. When a finger is  
inserted into the sensor’s rubber cushion, the SpO value auto-  
matically displays. The pulse bar graph displays th2e user’s pulse  
beat, and the bar graph’s height shows pulse strength. The  
oximeter, which is powered by two AAA batteries, features a low-  
battery indicator and powers off automatically in eight seconds  
when not in use.  
Check the pulse oximeter sensor application site frequent-  
ly to determine the positioning of the sensor and circula-  
tion and skin sensitivity of the user.  
Do not stretch the adhesive tape while applying the pulse  
oximeter sensor. This may cause inaccurate readings or  
skin blisters.  
Prolonged use or the user’s condition may require chang-  
ing the sensor site periodically. Change sensor site and  
check skin integrity, circulatory status, and correct align-  
ment at least every 4 hours.  
s NOTICE: Indicates a potential hazard or unsafe practice  
that, if not avoided, could result in product/property  
damage.  
Product Accessories (Included)  
1. One lanyard  
2. Two AAA batteries  
3. One protective cover  
4. One operator manual  
Principle of Measurement  
SETUP  
Battery Installation  
1. Open battery compartment cover.  
Two beams of different wavelength (660 nm glow and 940 nm  
near infrared light) are focused onto a human nail tip through a  
clamping finger-type sensor. A measured signal obtained by a  
photosensitive element, through processes of electronic circuits  
and microprocessor, will be shown on the oximeter’s display.  
2. Install two AAA batteries in battery compart-  
ment, ensuring that polarities are correct.  
3. Close battery compartment cover: Push cover horizontally  
along the arrow as shown at right.  
s NOTICE:  
Principle of Operation Diagram  
•Ensure battery polarities are correct, or the device could  
be damaged.  
See illustration and descriptions below.  
1
2
Red and Infrared Emission Tube  
Red and Infrared Receipt Tube  
Lanyard Installation  
1. Thread the thinner end of the lanyard through the oximeter  
loop.  
INTENDED USE  
2. Thread the thicker end of the lanyard through the threaded  
end, then pull it tightly.  
The intended use of the OxyCheck Fingertip Pulse Oximeter is  
the measurement and display of the functional oxygen satura-  
tion of arterial hemoglobin (SpO2) and pulse rate (PR) of adults  
and pediatric users in hospital, ambulatory, home, and EMS  
(Emergency Medical Service) environments. The Pulse Oxim-  
eter is intended for spot-checking these levels.  
OPERATION INSTRUCTIONS  
1. Use isopropyl alcohol to clean the test finger and the rubber  
inside the oximeter that touches the finger.  
2. Place clamp over fingernail as shown  
at right; insert finger, fingernail up as  
shown.  
Contraindications (  
WARNINGS):  
•If you do not understand any part of these instructions,  
contact a healthcare professional for direction in the use  
of this product.  
3. Press button on front panel once. User’s finger and body  
must remain still during measurement.  
4. See display: the SpO2 value automatically displays, the  
pulse bar graph displays the pulse rate, and the bar graph’s  
height shows the pulse strength.  
•This device is not intended for continuous monitoring.  
•Do not use this device in an explosive atmosphere.  
•Do not use this device in an MRI or CT environment.  
MAINTENANCE AND STORAGE  
INACCURATE MEASUREMENTS MAY BE CAUSED BY THE FOLLOWING:  
•Autoclaving, ethylene oxide sterilizing, or immersing the  
device in liquid  
•Significant levels of dysfunctional hemoglobins (such as  
carbonxy- hemoglobin or methemoglobin)  
•Intravascular dyes such as indocyanine green or methy-  
lene blue  
•High ambient light — shield the sensor area (with a surgi-  
cal towel, or direct sunlight, for example) if necessary  
•Excessive user movement  
•High-frequency electrosurgical interference  
Venous pulsations  
•Placement of a sensor on an extremity with a blood pres-  
sure cuff, arterial catheter, or intravascular line  
•User hypotension, severe vasoconstriction, severe ane-  
mia, or hypothermia  
s NOTICE:  
•This device contains no serviceable parts. Do not disas-  
semble.  
•Remove the batteries if the oximeter will not be used for a  
long period of time.  
•Do not autoclave, sterilize with ethylene oxide, or im-  
merse the device in liquid.  
•See SPECIFICATIONS/Environmental Requirements for  
operation and storage requirements. A wet ambience  
could damage this product and shorten its lifetime.  
•Recycle or dispose of this device and its used batteries in  
observance of local regulations.  
Info: Use isopropyl alcohol to clean the rubber (inside the  
oximeter, that touches the finger) and the test finger before  
and after each test. The rubber inside the oximeter is medi-  
cal rubber, which has no toxins, and is not harmful to the  
skin.  
•User cardiac arrest or shock  
Improper finger placement, e.g. fingernail not facing upward  
Replace the batteries when low battery indicator illuminates.  
•Fingernail polish or false fingernails.  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  

Haier Cell Phone N60 User Manual
HannsG Double Oven HB171 User Manual
Harman Kardon Stereo Receiver AVR 165 User Manual
Heath Zenith Work Light 52 4473 6 User Manual
Honeywell Automobile Parts N86XX User Manual
Honeywell Security Camera HD3VC4SAX User Manual
HP Hewlett Packard Photo Printer Z3200ps User Manual
HP Hewlett Packard Speaker 4275A User Manual
Huawei Cell Phone MC850 User Manual
IBM Network Card LAN 2100 3B User Manual