Kit Instructions
332653A
300 psi LPG Gauge for ThermoLazer
EN
Model 24T885
Important Safety Instructions
Read instruction manual 3A1319 for complete instructions and warnings. This Kit is not
a substitute for reading and understanding all instruction manuals and warning labels
supplied with the equipment.
1
6
11
10
14
3
7
8
4
5
Ref. Part
Description
Qty.
1
127257 GAUGE, pressure, 0-300 psi
16W412 TUBE, formed, gas
118484 FITTING, connector
104984 FITTING, tee, pipe
100030 BUSHING
156971 FITTING, nipple, short
100840 FITTING, elbow, street
16W635 FITTING, system filter assembly
108638 FITTING, pipe, tee
070408 SEALANT, pipe, sst (not shown)
110110 SEALANT, pipe, sst (not shown)
555459 PLUG, 1/4 npt brass hex hd
1
1
1
1
2
1
1
1
1
1
1
1
3
4
5
6
7
8
10
11
12
13
14
Download from Www.Somanuals.com. All Manuals Search And Download.
Pressure Tap Installation for ThermoLazer
Pressure Tap Installation for ThermoLazer
1. Close manual gas shutoff valve on propane tank.
9. Install new gas line (3) by screwing into gas safety
valve adapter fitting (164) and screwing into adapter
fitting (4). Screw in until gas tight.
8
14
5
164
ti14128a
ti22114a
2. Disconnect gas supply hose (99) from propane tank.
7
3
4
99
10. Connect gas supply hose (99) to propane tank.
99
ti22097a
3. Remove and discard existing gas line (3) by
unscrewing from elbow fitting (161) and unscrewing
from gas safety valve adapter fitting (164).
ti14411b
4. Remove and discard existing elbow fitting (161) by
unscrewing from manual gas shutoff valve (9).
11. Open manual gas shutoff valve on propane.
164
9
ti14127a
ti22104a
3
161
12. Check gas lines for gas leaks (see ThermoLazer
Operation Manual).
5. Apply pipe sealant to elbow fitting (8) and screw into
manual gas shutoff valve (9). Screw in until gas
tight. Position fitting as shown.
6. Apply pipe sealant to adapter fitting (7) and screw
into tee fitting (11). Screw in until gas tight.
7. Apply pipe sealant to adapter fitting (4) and screw
into tee fitting (11). Screw in until gas tight.
8. Apply pipe sealant to adapter fitting (7) and screw
into elbow fitting (8). Screw in until gas tight. Posi-
tion fittings as shown.
332653A
3
Download from Www.Somanuals.com. All Manuals Search And Download.
All written and visual data contained in this document reflects the latest product information available at the time of publication.
Graco reserves the right to make changes at any time without notice.
This manual contains English. MM 332653
Graco Headquarters: Minneapolis
International Offices: Belgium, China, Japan, Korea
GRACO INC. AND SUBSIDIARIES • P.O. BOX 1441 • MINNEAPOLIS MN 55440-1441 • USA
Copyright 2012, Graco Inc. All Graco manufacturing locations are registered to ISO 9001.
Revision A - 2013
Download from Www.Somanuals.com. All Manuals Search And Download.
|