		 Instructions - Parts   
					™ 
					Power-Lock   
					309572ZAG   
					Heated Hose   
					EN   
					For use with plural component proportioners. For professional use only.   
					Not approved for use in European explosive atmospheres.   
					
					
					130 psi (0.9 MPa, 9 bar) Maximum Air Working Pressure   
					180°F (82°C) Maximum Hose Operating Temperature   
					Important Safety instructions.   
					Read all warnings and instructions in this manual.   
					Save these instructions.   
					TI12157a   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Power-Lock Hose Bundle Part Numbers   
					Power-Lock Hose Bundle Part Numbers   
					You need at least one 50 ft (15.2 m) main hose, one fluid temperature sensor (FTS), and one whip hose or one wire   
					harness jumper (part no. 261821) to make a complete heated hose assembly. Be sure the selected hose meets your   
					maximum pressure and hose diameter requirements.   
					Whip Hoses   
					ETL   
					Approval /   
					Series B   
					Hose Fittings   
					“B”   
					Standard Xtreme-   
					Braided Wrap   
					“A”   
					Hose   
					Length   
					ID   
					Scuff   
					Scuff   
					inlet (f)/   
					inlet (f)/   
					Assembly ft (m)   
					in. (mm) Heated Guard   
					Guard   
					outlet (m) outlet (m)   
					2000 psi (13.8 MPa, 138 bar)   
					✔ 
					✔ 
					✔ 
					✔ 
					✔ 
					✔ 
					246050   
					249586   
					10 (3)   
					3 (0.9)   
					1/4 (6)   
					1/4 (6)   
					-5 JIC   
					-5 JIC   
					-6 JIC   
					-6 JIC   
					✔ 
					3500 psi (24.1 MPa, 241 bar)   
					✔ 
					✔ 
					246055   
					246056   
					10 (3)   
					10 (3)   
					1/4 (6)   
					3/8 (10)   
					-5 JIC   
					-5 JIC   
					-6 JIC   
					-6 JIC   
					✔ 
					✔ 
					5000 psi (34.5 MPa, 345 bar)   
					258701 10 (3) 1/4 (6)   
					✔ 
					-5 JIC   
					-6 JIC   
					◆ Individual heated A and B lines.   
					Adapter Fittings   
					Use adapter fittings to connect a hose assembly to a fluid manifold and/or a FTS. Use JIC swivel fittings to connect a   
					female FTS to male end hoses and/or npt female ball valves on mix manifold inlets.   
					Hose Fittings   
					Hose Fittings   
					Part   
					End #1   
					End #2   
					Part   
					4500 psi (31 MPa, 310 bar)   
					117833 3/8 npt (m)   
					5000 psi (34.5 MPa, 345 bar)   
					End #1   
					End #2   
					126431   
					126432   
					1/2 npt (m)   
					1/2 npt (m)   
					-6 JIC (f), swivel   
					-6 JIC (f), 45°   
					-8 JIC (m)   
					7250 psi (50 MPa, 500 bar)   
					100206   
					121433   
					159841   
					1/2 npt (m)   
					1/2 npt (m)   
					3/8 npt (m)   
					1/4 (f)   
					3/8 (f)   
					1/4 (f)   
					116702   
					116703   
					116704   
					116765   
					117506   
					117832   
					119998   
					122406   
					126327   
					126328   
					126329   
					126330   
					126339   
					1/4 npt (m)   
					1/4 npt (m)   
					1/4 npt (m)   
					3/8 npt (m)   
					1/4 npt (m)   
					3/8 npt (m)   
					1/4 npt (m)   
					3/8 npt (m)   
					3/8 npt (m)   
					3/8 npt (m)   
					1/2 npt (m)   
					1/2 npt (m)   
					3/8 npt (m)   
					-10 JIC (m)   
					-8 JIC (m)   
					-6 JIC (m)   
					7400 psi (51 MPa, 510 bar)   
					-10 JIC (m)   
					158491   
					159239   
					162449   
					1/2 npt (m)   
					1/2 npt (m)   
					1/2 npt (m)   
					1/2 (m)   
					3/8 (m)   
					1/4 (m)   
					-6 JIC (f), swivel   
					-6 JIC (m)   
					-5 JIC (m)   
					-5 JIC (m)   
					7500 psi (52 MPa, 517 bar)   
					156971 1/4 npt (m)   
					8000 psi (55 MPa, 552 bar)   
					164856 1/4 npt (m)   
					-6 JIC (f), swivel   
					-8 JIC (f), swivel   
					-8 JIC (f), swivel   
					-10 JIC (f), swivel   
					-10 JIC (f), swivel   
					1/4 (m)   
					3/8 (m)   
					6000 psi (41 MPa, 414 bar)   
					117595   
					1/4 npt (m)   
					-5 JIC (f), swivel   
					309572ZAG   
					3 
					Download from Www.Somanuals.com. All Manuals Search And Download.   
					 
					 
					 
				Power-Lock Hose Bundle Part Numbers   
					Standard 2 Component Hose   
					Hose Fittings   
					Standard   
					Braided Xtreme-W   
					“A”   
					“B”   
					ETL   
					Hose   
					Assembly   
					Length   
					ft (m) in. (mm) Cable   
					ID   
					FTS   
					Scuff   
					Guard   
					rap Scuff inlet (f)/   
					inlet (f)/   
					“A”   
					“B”   
					Approval /   
					Series B   
					Guard   
					outlet (m) outlet (m) Red Hose Blue Hose   
					2000 psi (13.8 MPa, 138 bar)   
					✔ 
					✔ 
					✔ 
					246045   
					246046   
					246047   
					246074   
					246075   
					246076   
					246678   
					24Y678   
					256549   
					24Y549   
					249587   
					261328   
					246048   
					246049   
					50 (15.2) 1/4 (6)   
					50 (15.2) 3/8 (10)   
					50 (15.2) 1/2 (13)   
					50 (15.2) 1/4 (6)   
					50 (15.2) 3/8 (10)   
					50 (15.2) 1/2 (13)   
					50 (15.2) 3/8 (10)   
					50 (15.2) 3/8 (10)   
					50 (15.2) 3/8 (10)   
					50 (15.2) 3/8 (10)   
					25 (7.6) 1/4 (6)   
					25 (7.6) 3/8 (10)   
					25 (7.6) 1/4 (6)   
					25 (7.6) 3/8 (10)   
					-5 JIC   
					-5 JIC   
					-8 JIC   
					-5 JIC   
					-5 JIC   
					-8 JIC   
					-5 JIC   
					-5 JIC   
					-5 JIC   
					-5 JIC   
					-5 JIC   
					-5 JIC   
					-5 JIC   
					-5 JIC   
					-6 JIC   
					-6 JIC   
					-10 JIC   
					-6 JIC   
					-6 JIC   
					-10 JIC   
					-6 JIC   
					-6 JIC   
					-6 JIC   
					-6 JIC   
					-6 JIC   
					-6 JIC   
					-6 JIC   
					-6 JIC   
					246059   
					246061   
					246063   
					246059   
					246061   
					246063   
					246061   
					246061   
					246061   
					246069   
					246065   
					246094   
					246065   
					246094   
					246060   
					246062   
					246064   
					246060   
					246062   
					246064   
					246062   
					246062   
					246062   
					246070   
					246066   
					246095   
					246066   
					246095   
					✔ 
					✔ 
					✔ 
					✔ 
					✔ 
					✔ 
					✔ 
					✔ 
					✔ 
					✔ 
					✔ 
					✔ 
					✔ 
					✔ 
					✔ 
					✔ 
					✔ 
					3500 psi (24.1 MPa, 241 bar)   
					✔ 
					✔ 
					✔ 
					246052   
					246053   
					246054   
					249588   
					246679   
					24Y679   
					256548   
					261335   
					50 (15.2) 1/4 (6)   
					50 (15.2) 3/8 (10)   
					50 (15.2) 1/2 (13)   
					50 (15.2) 3/8 (10)   
					50 (15.2) 3/8 (10)   
					50 (15.2) 3/8 (10)   
					50 (15.2) 1/2 (13)   
					50 (15.2) 1/2 (13)   
					-5 JIC   
					-5 JIC   
					-8 JIC   
					-5 JIC   
					-5 JIC   
					-5 JIC   
					-8 JIC   
					-8 JIC   
					-6 JIC   
					-6 JIC   
					-10 JIC   
					-6 JIC   
					-6 JIC   
					-6 JIC   
					-10 JIC   
					-10 JIC   
					246067   
					246069   
					246071   
					246069   
					246069   
					246069   
					246071   
					246071   
					246068   
					246070   
					246072   
					246070   
					246070   
					246070   
					246072   
					246072   
					✔ 
					✔ 
					✔ 
					✔ 
					✔ 
					✔ 
					✔ 
					✔ 
					✔ 
					✔ 
					✔ 
					✔ 
					✔ 
					5000 psi (34.5 MPa, 345 bar)   
					261332   
					262203   
					25 (7.6) 3/8 (10)   
					50 (15.2) 3/8 (10)   
					-5 JIC   
					-5 JIC   
					-6 JIC   
					-6 JIC   
					✔ 
					15E751   
					15E752   
					RTD 2-Component Hose (for use with GCA Controlled Reactors)   
					Hose Fittings   
					Standard Xtreme-   
					Braided   
					Scuff   
					Guard   
					Wrap   
					Scuff   
					Guard   
					“A”   
					inlet (f)/   
					“B”   
					inlet (f)/   
					“A”   
					Red   
					“B”   
					ETL   
					Hose   
					Assembly   
					Length   
					ft (m)   
					ID   
					RTD   
					CAN   
					Blue Approval/   
					Hose   
					in. (mm) Cable   
					Cable outlet (m) outlet (m) Hose   
					Series B   
					2000 psi (13.8 MPa, 138 bar)   
					✔ 
					✔ 
					✔ 
					✔ 
					✔ 
					✔ 
					✔ 
					✔ 
					✔ 
					✔ 
					✔ 
					✔ 
					✔ 
					✔ 
					✔ 
					✔ 
					24K240   
					24Y240   
					24K394   
					24T839   
					24Y394   
					24N000   
					24N001   
					50 (15.2) 3/8 (10)   
					50 (15.2) 3/8 (10)   
					50 (15.2) 3/8 (10)   
					50 (15.2) 3/8 (10)   
					50 (15.2) 3/8 (10)   
					50 (15.2) 1/2 (13)   
					50 (15.2) 1/2 (13)   
					-5 JIC   
					-5 JIC   
					-5 JIC   
					-5 JIC   
					-5 JIC   
					-8 JIC   
					-8 JIC   
					-6 JIC   
					-6 JIC   
					-6 JIC   
					-6 JIC   
					-6 JIC   
					-10 JIC   
					-10 JIC   
					246061 246062   
					246061 246062   
					246061 246062   
					246061 246062   
					246061 246062   
					246063 246064   
					246063 246064   
					✔ 
					✔ 
					✔ 
					✔ 
					✔ 
					✔ 
					✔ 
					4 
					309572ZAG   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
					 
					 
				Power-Lock Hose Bundle Part Numbers   
					Hose Fittings   
					Standard Xtreme-   
					Braided   
					Scuff   
					Guard   
					Wrap   
					Scuff   
					Guard   
					“A”   
					inlet (f)/   
					“B”   
					inlet (f)/   
					“A”   
					Red   
					“B”   
					ETL   
					Hose   
					Assembly   
					Length   
					ft (m)   
					ID   
					RTD   
					CAN   
					Blue Approval/   
					Hose   
					in. (mm) Cable   
					Cable outlet (m) outlet (m) Hose   
					Series B   
					3500 psi (24.1 MPa, 241 bar)   
					✔ 
					✔ 
					✔ 
					✔ 
					✔ 
					✔ 
					✔ 
					✔ 
					✔ 
					✔ 
					✔ 
					✔ 
					✔ 
					✔ 
					✔ 
					✔ 
					24K241   
					24Y241   
					24K395   
					24Y395   
					24U743   
					24N002   
					24N003   
					50 (15.2) 3/8 (10)   
					50 (15.2) 3/8 (10)   
					50 (15.2) 3/8 (10)   
					50 (15.2) 3/8 (10)   
					50 (15.2) 3/8 (10)   
					50 (15.2) 1/2 (13)   
					50 (15.2) 1/2 (13)   
					-5 JIC   
					-5 JIC   
					-5 JIC   
					-5 JIC   
					-5 JIC   
					-8 JIC   
					-8 JIC   
					-6 JIC   
					-6 JIC   
					-6 JIC   
					-6 JIC   
					-6 JIC   
					-10 JIC   
					-10 JIC   
					246069 246070   
					246069 246070   
					246069 246070   
					246069 246070   
					246069 246070   
					246071 246072   
					246071 246072   
					✔ 
					✔ 
					✔ 
					✔ 
					✔ 
					✔ 
					✔ 
					Airless 2 Component Hose   
					ID   
					in. (mm)   
					Hose Fittings   
					Standard   
					Braided   
					Scuff   
					“A”   
					“B”   
					Hose   
					Assembly   
					Length   
					ft (m)   
					FTS   
					inlet (f)/   
					inlet (f)/   
					“A”   
					“B”   
					“A”   
					“B”   
					Cable   
					Guard   
					outlet (m)   
					outlet (m)   
					Red Hose Blue Hose   
					5000 psi (34.5 MPa, 345 bar)   
					✔ 
					✔ 
					✔ 
					✔ 
					✔ 
					248907   
					248908   
					262727   
					262728   
					262730   
					50 (15.2)   
					50 (15.2)   
					50 (15.2)   
					50 (15.2)   
					50 (15.2)   
					1/4 (6) 3/8 (10)   
					3/8 (10) 3/8 (10)   
					1/2 (13) 1/4 (6)   
					1/2 (13) 3/8 (10)   
					1/2 (13) 1/2 (13)   
					-5 JIC   
					-6 JIC   
					15E750   
					15E751   
					262719   
					262719   
					262719   
					15E752   
					15E752   
					262718   
					15E752   
					262720   
					-5 JIC   
					-8 JIC   
					-8 JIC   
					-8 JIC   
					-6 JIC   
					-6 JIC   
					-6 JIC   
					-10 JIC   
					Custom Application 2 Component Hose   
					ID   
					in. (mm)   
					Hose Fittings   
					Standard   
					Braided   
					Scuff   
					“A”   
					“B”   
					Hose   
					Assembly   
					Length   
					ft (m)   
					FTS   
					Cable   
					inlet (f)/   
					outlet (m)   
					inlet (f)/   
					outlet (m)   
					“A”   
					“B”   
					“A”   
					“B”   
					Guard   
					Red Hose Blue Hose   
					2000 psi (13.8 MPa, 138 bar)   
					255089 50 (15.2) 1/4 (6)   
					3500 psi (24.1 MPa, 241 bar)   
					✔ 
					✔ 
					✔ 
					3/8 (10)   
					-5 JIC   
					-6 JIC   
					246059   
					246062   
					✔ 
					✔ 
					247164   
					261336   
					261337   
					24N524   
					50 (15.2) 1/4 (6)   
					3/8 (10)   
					-5 JIC   
					-5 JIC   
					-5 JIC   
					-5 JIC   
					-6 JIC   
					-6 JIC   
					-6 JIC   
					-10 JIC   
					246067   
					246069   
					246067   
					246067   
					246070   
					246072   
					246070   
					246072   
					50 (15.2) 3/8 (10) 1/2 (13)   
					50 (15.2) 1/4 (6)   
					50 (15.2) 1/4 (6)   
					3/8 (10)   
					1/2 (13)   
					‡ 
					✔ 
					✔ 
					✖ Stranded wire (no connectors).   
					‡ Two FTS cables and two sets of standard wires.   
					309572ZAG   
					5 
					Download from Www.Somanuals.com. All Manuals Search And Download.   
					 
					 
				Power-Lock Hose Bundle Part Numbers   
					Fluid Temperature Sensor (FTS) Kits   
					“A” Side   
					Outlet   
					5000 psi (34.5 MPa, 345 bar)   
					“B” Side   
					Part No.   
					Inlet   
					FTS Probe Inlet   
					Outlet   
					FTS Probe   
					✔ 
					261669   
					261670   
					-5 JIC   
					-5 JIC   
					-5 JIC   
					-6 JIC   
					-6 JIC   
					✔ 
					1/4 NPT   
					-6 JIC   
					3/8 NPT   
					7250 psi (50 MPa, 500 bar)   
					24M943 1/2 npt (f) 1/2 (npt (f)   
					✔ 
					1/2 npt (f) 1/2 (npt (f)   
					Fluid Temperature Sensor Kits (FTS, RTD;   
					for use with GCA Controlled Systems)   
					“A” Side   
					Outlet   
					5000 psi (34.5 MPa, 345 bar)   
					24K207 -5 JIC -5 JIC   
					7250 psi (50 MPa, 500 bar)   
					“B” Side   
					Outlet RTD Probe   
					Part No.   
					Inlet   
					RTD Probe Inlet   
					✔ 
					-6 JIC   
					-6 JIC   
					✔ 
					24M944   
					1/2 npt (f) 1/2 (npt (f)   
					1/2 npt (f) 1/2 (npt (f)   
					FTS kits contain:   
					• 
					• 
					• 
					• 
					• 
					FTS Sensor   
					FTS coupler fitting (5b) for equal length on other line.   
					
					Foam tube insulation to cover fittings and FTS.   
					3.75 in. (95.25 mm) air line jumper hose (except kit 261670).   
					6 
					309572ZAG   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
					 
					 
				Warnings   
					Warnings   
					The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama-   
					tion point symbol alerts you to a general warning and the hazard symbol refers to procedure-specific risk. When   
					these symbols appear in the body of this manual, refer back to these Warnings. Product-specific hazard symbols and   
					warnings not covered in this section may appear throughout the body of this manual where applicable.   
					WARNING   
					ELECTRIC SHOCK HAZARD   
					The hoses must be grounded. Improper grounding, set-up, or usage of hoses can cause electric   
					shock.   
					• 
					• 
					• 
					Turn off and disconnect power before installing or servicing hoses.   
					Connect only to grounded power source.   
					All electrical wiring must be done by a qualified electrician and comply with all local codes and   
					regulations.   
					• 
					• 
					Never cut or puncture a hose cover.   
					Do not expose to rain. Store indoors.   
					SKIN INJECTION HAZARD   
					High-pressure fluid from hose leaks, or ruptured components will pierce skin. This may look like just a   
					cut, but it is a serious injury that can result in amputation. Get immediate surgical treatment.   
					• 
					• 
					• 
					• 
					• 
					• 
					• 
					• 
					Inspect hose before each use for cuts, bulges, kinks or any other damage.   
					Replace damaged hose immediately.   
					Replace hoses proactively at regular intervals based on your operating conditions.   
					Tighten all fluid connections before operating the equipment.   
					Keep clear of leaks.   
					Do not stop or deflect leaks with your hand, body, glove, or rag.   
					Never exceed hose Maximum Pressure or Temperature ratings.   
					Only use chemicals that are compatible with hose materials. See Technical Data in this manual.   
					Read Safety Data Sheet (SDS) and fluid and solvent manufacturer’s recommendations.   
					Follow the Pressure Relief Procedure when you stop spraying/dispensing and before cleaning,   
					checking, or servicing equipment.   
					• 
					THERMAL EXPANSION HAZARD   
					Fluids subjected to heat in confined spaces, including hoses, can create a rapid rise in pressure due to   
					the thermal expansion. Over-pressurization can result in equipment rupture and serious injury.   
					• 
					• 
					Open a valve to relieve the fluid expansion during heating.   
					Replace hoses proactively at regular intervals based on your operating conditions.   
					BURN HAZARD   
					Equipment surfaces and fluid that is heated can become very hot during operation. To avoid severe   
					burns:   
					• 
					Do not touch hot fluid or equipment.   
					309572ZAG   
					7 
					Download from Www.Somanuals.com. All Manuals Search And Download.   
					 
				Warnings   
					WARNING   
					TOXIC FLUID OR FUMES HAZARD   
					Toxic fluids or fumes can cause serious injury or death if splashed in the eyes or on skin, inhaled or   
					swallowed.   
					• 
					• 
					Read Safety Data Sheet (SDS) for handling instructions and to know the specific hazards of the fluids   
					you are using, including the effects of long-term exposure.   
					When spraying, servicing equipment, or when in the work area, always keep work area well venti-   
					lated and always wear appropriate personal protective equipment. See Personal Protective Equip-   
					ment warnings in this manual.   
					• 
					Store hazardous fluid in approved containers, and dispose of it according to applicable guidelines.   
					FIRE AND EXPLOSION HAZARD   
					Flammable fumes, such as solvent and paint fumes, in work area can ignite or explode. Paint or sol-   
					vent flowing through the equipment can cause static sparking. To help prevent fire and explosion:   
					• 
					• 
					Use equipment only in well ventilated area.   
					Eliminate all ignition sources; such as pilot lights, cigarettes, portable electric lamps, and plastic drop   
					cloths (potential static sparking).   
					• 
					• 
					• 
					• 
					Ground all equipment in the work area. See Grounding instructions.   
					Never spray or flush solvent at high pressure.   
					Keep work area free of debris, including solvent, rags and gasoline.   
					Do not plug or unplug power cords, or turn power or light switches on or off when flammable fumes   
					are present.   
					• 
					• 
					Use only grounded hoses.   
					Hold gun firmly to side of grounded pail when triggering into pail. Do not use pail liners unless they   
					are anti-static or conductive.   
					• 
					• 
					Stop operation immediately if static sparking occurs or you feel a shock. Do not use equipment   
					until you identify and correct the problem.   
					Keep a working fire extinguisher in the work area.   
					EQUIPMENT MISUSE HAZARD   
					Misuse can cause death or serious injury.   
					• 
					• 
					Do not operate the unit when fatigued or under the influence of drugs or alcohol.   
					Do not exceed the maximum working pressure or temperature rating of the lowest rated system com-   
					ponent. See Technical Data in all equipment manuals.   
					• 
					Use fluids and solvents that are compatible with equipment wetted parts. See Technical Data in all   
					equipment manuals. Read fluid and solvent manufacturer’s warnings. For complete information   
					about your material, request Safety Data Sheet (SDS) from distributor or retailer.   
					Do not leave the work area while equipment is energized or under pressure.   
					Turn off all equipment and follow the Pressure Relief Procedure when equipment is not in use.   
					Check equipment daily. Repair or replace worn or damaged parts immediately with genuine manu-   
					facturer’s replacement parts only.   
					• 
					• 
					• 
					• 
					Do not alter or modify equipment. Alterations or modifications may void agency approvals and create   
					safety hazards.   
					• 
					• 
					• 
					• 
					• 
					• 
					Make sure all equipment is rated and approved for the environment in which you are using it.   
					Use equipment only for its intended purpose. Call your distributor for information.   
					Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces.   
					Do not kink or over bend hoses or use hoses to pull equipment.   
					Keep children and animals away from work area.   
					Comply with all applicable safety regulations.   
					8 
					309572ZAG   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Important Isocyanate (ISO) Information   
					WARNING   
					PERSONAL PROTECTIVE EQUIPMENT   
					Always wear appropriate personal protective equipment and cover all skin when spraying, servicing   
					equipment, or when in the work area. Protective equipment helps prevent serious injury, including   
					long-term exposure; inhalation of toxic fumes, mists or vapors; allergic reaction; burns; eye injury and   
					hearing loss. This protective equipment includes but is not limited to:   
					• 
					A properly fitting respirator, which may include a supplied-air respirator, chemically impermeable   
					gloves, protective clothing and foot coverings as recommended by the fluid manufacturer and local   
					regulatory authority.   
					• 
					Protective eyewear and hearing protection.   
					Important Isocyanate (ISO) Information   
					Isocyanate Conditions   
					Spraying or dispensing fluids that contain isocyanates creates potentially harmful mists, vapors, and atomized   
					particulates.   
					• 
					• 
					Read and understand the fluid manufacturer’s warnings and Safety Data Sheet (SDS) to know specific hazards and   
					precautions related to isocyanates.   
					Use of isocyanates involves potentially hazardous procedures. Do not spray with this equipment unless you are trained,   
					qualified, and have read and understood the information in this manual and in the fluid manufacturer’s application   
					instructions and SDS.   
					• 
					• 
					• 
					Use of incorrectly maintained or mis-adjusted equipment may result in improperly cured material.which could cause off   
					gassing and offensive odors. Equipment must be carefully maintained and adjusted according to instructions in the   
					manual.   
					To prevent inhalation of isocyanate mists, vapors and atomized particulates, everyone in the work area must wear   
					appropriate respiratory protection. Always wear a properly fitting respirator, which may include a supplied-air respirator.   
					Ventilate the work area according to instructions in the fluid manufacturer’s SDS.   
					Avoid all skin contact with isocyanates. Everyone in the work area must wear chemically impermeable gloves, protec-   
					tive clothing and foot coverings as recommended by the fluid manufacturer and local regulatory authority. Follow all   
					fluid manufacturer recommendations, including those regarding handling of contaminated clothing. After spraying,   
					wash hands and face before eating or drinking.   
					• 
					• 
					Hazard from exposure to isocyanates continues after spraying. Anyone without appropriate personal protective equip-   
					ment must stay out of the work area during application and after application for the time period specified by the fluid   
					manufacturer. Generally this time period is at least 24 hours.   
					Warn others who may enter work area of hazard from exposure to isocyanates. Follow the recommendations of the fluid   
					manufacturer and local regulatory authority. Posting a placard such as the following outside the work area is recom-   
					mended:   
					TOXIC FUMES   
					HAZARD   
					DO NOT ENTER DURING   
					SPRAY FOAM APPLICATION   
					OR FOR ___ HOURS AFTER   
					APPLICATION IS COMPLETE   
					DO NOT ENTER UNTIL:   
					DATE: ____________   
					TIME: ____________   
					309572ZAG   
					9 
					Download from Www.Somanuals.com. All Manuals Search And Download.   
					 
					 
				Important Isocyanate (ISO) Information   
					For all applications except spray   
					foam   
					Material Self-ignition   
					Some materials may become self-igniting if applied   
					too thick. Read material manufacturer’s warnings and   
					Safety Data Sheet (SDS).   
					Spraying or dispensing fluids that contain isocya-   
					nates creates potentially harmful mists, vapors, and   
					atomized particulates.   
					Keep Components A and B   
					Separate   
					• 
					Read and understand the fluid manufacturer’s   
					warnings and Safety Data Sheet (SDS) to know   
					specific hazards and precautions related to iso-   
					cyanates.   
					• 
					Use of isocyanates involves potentially hazard-   
					ous procedures. Do not spray with this equip-   
					ment unless you are trained, qualified, and have   
					read and understood the information in this   
					manual and in the fluid manufacturer’s applica-   
					tion instructions and SDS.   
					Cross-contamination can result in cured material in fluid   
					lines which could cause serious injury or damage   
					equipment. To prevent cross-contamination:   
					• 
					Never interchange component A and component B   
					wetted parts.   
					• 
					Never use solvent on one side if it has been contam-   
					inated from the other side.   
					• 
					• 
					Use of incorrectly maintained or mis-adjusted   
					equipment may result in improperly cured mate-   
					rial. Equipment must be carefully maintained   
					and adjusted according to instructions in the   
					manual.   
					To prevent inhalation of isocyanate mists,   
					vapors, and atomized particulates, everyone in   
					the work area must wear appropriate respiratory   
					protection. Always wear a properly fitting respi-   
					rator, which may include a supplied-air respira-   
					tor. Ventilate the work area according to   
					instructions in the fluid manufacturer’s SDS.   
					• 
					Avoid all skin contact with isocyanates. Every-   
					one in the work area must wear chemically   
					impermeable gloves, protective clothing and   
					foot coverings as recommended by the fluid   
					manufacturer and local regulatory authority. Fol-   
					low all fluid manufacturer recommendations,   
					including those regarding handling of contami-   
					nated clothing. After spraying, wash hands and   
					face before eating or drinking.   
					10   
					309572ZAG   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
					 
					 
				Important Isocyanate (ISO) Information   
					Moisture Sensitivity of   
					Isocyanates   
					Changing Materials   
					NOTICE   
					Exposure to moisture (such as humidity) will cause ISO   
					to partially cure, forming small, hard, abrasive crystal   
					that become suspended in the fluid. Eventually a film will   
					form on the surface and the ISO will begin to gel,   
					increasing in viscosity.   
					Changing the material types used in your equipment   
					requires special attention to avoid equipment damage   
					and downtime.   
					• 
					When changing materials, flush the equipment   
					multiple times to ensure it is thoroughly clean.   
					NOTICE   
					• 
					• 
					Always clean the fluid inlet strainers after flushing.   
					Partially cured ISO will reduce performance and the   
					life of all wetted parts.   
					Check with your material manufacturer for chemi-   
					cal compatibility.   
					• 
					Always use a sealed container with a desiccant   
					dryer in the vent, or a nitrogen atmosphere. Never   
					store ISO in an open container.   
					• 
					When changing between epoxies and urethanes   
					or polyureas, disassemble and clean all fluid com-   
					ponents and change hoses. Epoxies often have   
					amines on the B (hardener) side. Polyureas often   
					have amines on the B (resin) side.   
					• 
					Keep the ISO pump wet cup or reservoir (if   
					installed) filled with appropriate lubricant. The   
					lubricant creates a barrier between the ISO and   
					the atmosphere.   
					• 
					• 
					Use only moisture-proof hoses compatible with   
					ISO.   
					Never use reclaimed solvents, which may contain   
					moisture. Always keep solvent containers closed   
					when not in use.   
					• 
					Always lubricate threaded parts with an appropri-   
					ate lubricant when reassembling.   
					NOTE: The amount of film formation and rate of crystal-   
					lization varies depending on the blend of ISO, the   
					humidity, and the temperature.   
					Foam Resins with 245 fa   
					Blowing Agents   
					Some foam blowing agents will froth at temperatures   
					above 90°F (33°C) when not under pressure, especially   
					if agitated. To reduce frothing, minimize preheating in a   
					circulation system.   
					309572ZAG   
					11   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
					 
					 
					 
				Installation   
					Installation   
					Description   
					This hose must be used with an FTS and   
					cable to provide grounding.   
					The heated hose maintains proper fluid tem-   
					perature while spraying.   
					Fluid hoses are marked with red tape for   
					ISO/hardener/minor volume side, blue tape for   
					RES/resin/major volume side. Fittings have   
					different sized threads to prevent incorrect   
					connection, which can cause fluid crossover   
					and permanently damage the hose.   
					Hoses are 50 ft (15.2 m) or 25 ft (7.6 m) long.   
					The whip hose is 10 ft (3 m) long or less.   
					To heat the major volume hose only in a   
					wide ratio system, see 15F144 Hose   
					
					12   
					309572ZAG   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
					 
					 
				Installation   
					Connect Whip Hose to Gun or Gun Manifold   
					Install hose in a helix configuration for:   
					• Easy gun movement   
					• Large spraying motion   
					• Ability to spray in tight areas and odd angles   
					• Reduced operator fatigue   
					• Maximum hose life   
					1. Overlap A and B component hoses and   
					assemble to gun or gun manifold fittings as   
					
					2. Tighten fittings to A and B component   
					hoses. Ensure hose remains flat after fit-   
					tings are tightened. Loosen and retighten   
					fittings as necessary to eliminate any   
					torque on hoses. This will help achieve a   
					flat profile on the hose.   
					Tighten   
					Tighten   
					Tighten   
					TI12158a   
					TI14721a   
					FIG. 1   
					309572ZAG   
					13   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
					 
					 
				Installation   
					Connect Heated Hoses   
					1. Lay heated hoses end to end, matching the   
					color coding. Red for component A (ISO),   
					blue for component B (RES).   
					1 
					2 
					B 
					TI2679B   
					FIG. 3   
					Do not connect the main air supply at   
					this time.   
					A 
					Some insulated heated hoses do not   
					contain an air hose.   
					TI2678B   
					FIG. 2   
					3. Connect air hoses (3).   
					2. Connect fluid hoses (1, 2) and tighten. See   
					maximum torque specifications below and   
					
					Torque 1/4 in. (6.4 mm) and 3/8 in. (9.5 mm)   
					ID hoses to:   
					12   
					• A side to 14 ft-lb (19 N•m).   
					• B side to 20 ft-lb (27 N•m).   
					TI2682B   
					3 
					Torque 1/2 in.(13 mm) ID hoses to:   
					• A side to 43 ft-lb (58 N•m).   
					• B side to 55 ft-lb (74 N•m).   
					FIG. 4   
					14   
					309572ZAG   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
					 
					 
				Installation   
					4. Connect electrical wires.   
					b. If wire is short of ferrule end, adjust strip   
					length accordingly. If bare wire is pro-   
					truding from ferrule, trim flush to ferrule   
					end. See FIG. 6.   
					NOTE: Newer Series B hoses have a   
					pre-crimped ferrule. If using a Series B   
					hose, skip to step 5.   
					Incorrect   
					a. Ensure electrical wires ends are 5/8 in.   
					(15.9 mm) long. If they are not, use a   
					sharp scissors to strip all four wire ends   
					to the correct length. See Strip Length   
					Gauge for correct length.   
					Correct   
					Incorrect   
					TI9768a   
					FIG. 6   
					Strip Length   
					c. Remove ferrule and apply oxide inhibi-   
					
					d. Reinsert wire in ferrule and apply more   
					oxide inhibitor to ferrule and wire end.   
					5/8 in.   
					This illustration is not to scale.   
					(0.625 mm)   
					TI9733a   
					FIG. 5   
					Be careful not to cut or nick copper   
					strands. If more than five strands are cut   
					or nicked, trim wire and re-strip.   
					TI9769A   
					New hoses are pre-stripped at correct   
					length; remove insulation to expose bare   
					wire.   
					FIG. 7   
					a. Ensure strip length is correct by fitting   
					ferrule over exposed wire. Ferrule   
					should be flush with wire end. See FIG.   
					6.   
					On some older heated hoses wire insula-   
					tion will not fit inside ferrule insulator. In   
					these cases, use scissors to split and   
					remove ferrule insulator.   
					309572ZAG   
					15   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
					 
				Installation   
					5. Connect the hoses to each other. Pair elec-   
					trical wires as follows: A-Hose to A-Hose;   
					B-Hose to B-Hose.   
					c. Insert remaining wire from pair into con-   
					nector; ensure proper insertion depth.   
					Thread setscrew and torque to 60 in-lbs   
					(6.78 N•m); see sub-step B. See FIG. 8   
					and FIG. 9.   
					When connecting first hose section to   
					proportioner, wire pairing does not make   
					a difference.   
					d. Repeat sub-steps A through C for   
					remaining wire pair.   
					e. Re-torque all four setscrews to 60 in-lbs   
					(6.78 N•m).   
					When connecting hose to the propor-   
					tioner, always check the hoses for leaks   
					
					When torqued to 60 in-lbs (6.78 N•m)   
					setscrews will be approximately flush   
					with connector. See FIG. 10.   
					a. Insert one wire from heated hose into   
					connector. Ensure that ferrule is mating   
					with connector insert. See FIG. 8.   
					f. Insert cap plugs over setscrews. See   
					FIG. 10.   
					Cap plugs   
					TI9770A   
					Setscrews   
					TI9771A   
					FIG. 8: Insert Wire and Setscrew   
					FIG. 10   
					b. Thread in setscrew and use hex wrench   
					to torque setscrew to 60 in-lbs (6.78   
					N•m).   
					g. Wrap connector and wire on each side   
					of connector in black electrical tape to   
					help seal out moisture. Ensure 1 in.   
					(25.4 mm) of wire on each side of con-   
					nector is wrapped.   
					To reach approximately 60 in-lbs (6.78   
					N•m), complete 4.5 revolutions with hex   
					wrench after setscrew comes in contact   
					with ferrule.   
					TI9779A   
					FIG. 9: Torque Setscrew   
					16   
					309572ZAG   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Installation   
					6. For non-RTD hoses only, connect   
					thermocouple cables (4). Slide insulator   
					sleeves (S) over connection. Leave slack   
					in cables as stress relief to prevent cable   
					failure.   
					S 
					4 
					TI2683B   
					FIG. 11   
					7. For RTD 2-component hoses only, connect   
					RTD cables (4) and CAN cables (5) if pres-   
					ent.   
					4 
					5 
					TI18358a   
					FIG. 12   
					8. Repeat for additional hoses.   
					
					
					
					
					309572ZAG   
					17   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Installation   
					Connect FTS and Heated Dual Whip Hose   
					4. Connect ground wire (K) of whip hose to   
					NOTICE   
					the ground screw on the FTS (5a).   
					To prevent damage to probe, do not kink or   
					excessively bend hose. Do not coil hose   
					tighter than the minimum bend radius of 3 ft   
					(0.9 m). Do not subject hose to excessive   
					weight, impact, or other abuse.   
					A grounding wire must be used to provide   
					grounding.   
					Whip hose ground wire (K) must be   
					connected to the ground screw on the   
					FTS (5a) in order to drain static from the   
					gun. If the FTS is not directly connected   
					to the whip hose, a hose that includes a   
					separate ground wire must be used   
					between the FTS and whip hose. Con-   
					nect ground through a hose marked as   
					not having the FTS cable selected from   
					the “Standard 2 Component Hose” table   
					in the front of this manual.   
					
					For 1/2 in. (13 mm) ID fluid hoses   
					only: Prior to connecting the FTS,   
					remove the adapters from the propor-   
					tioner fluid manifold and install them on   
					the male ends of the hoses (1 and 2).   
					Torque the A side hose to a maximum   
					of 43 ft-lbs (58 N•m) and the B side   
					hose to a maximum of 55 ft-lbs (74   
					N•m). Continue on to step 1.   
					5. Connect the electrical connectors (12).   
					1. Assemble JIC swivel fitting (5e) in female   
					end of temp sensor (5a). Do not bend or   
					kink probe. Torque connection to 14 ft-lbs   
					(19 N•m). Do not over-torque. Assemble   
					JIC swivel fitting (5d) into female end of B   
					hose coupler (5b). Torque to a maximum of   
					20 ft-lbs (27 N•m). Do not over-torque.   
					6. Connect the FTS air line coupler (5c)   
					between air hoses (3 and 8).   
					7. Connect the sensor cable of the hose (4) to   
					the sensor cable of the FTS (5a). For   
					non-RTD hoses, slide the insulator sleeves   
					(S) over the connection. Leave slack in the   
					cables to provide stress relief and to pre-   
					vent cable failure or errors.   
					2. Carefully inset FTS probe into the A hose   
					(1) section from the proportioner. Do not   
					bend or kink probe. Connect to A side whip   
					(6a). Torque fitting connections to 14 ft-lbs   
					(19 N•m). Do not over-torque.   
					
					
					9. Cover the FTS and spacer with split foam   
					(provided) and tape closed.   
					NOTICE   
					To avoid damage to FTS sensor cable,   
					rotate FTS body so the cable lays between   
					both fluid hoses to protect it from abrasive   
					damage during use.   
					3. Connect the B hose coupler to the B hose   
					section (2) and B side whip (6b). Torque fit-   
					ting connections to 20 ft-lbs (27 N•m). Do   
					not over-torque.   
					18   
					309572ZAG   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
					 
				Installation   
					Connect FTS with a Non-Heated Whip Hose or Remote Mix   
					Manifold   
					3. Connect fluid hoses to FTS.   
					NOTICE   
					To prevent damage to probe, do not kink or   
					To use 1/2 in. (13 mm) ID fluid hoses,   
					excessively bend hose. Do not coil hose   
					remove the adapters from the propor-   
					tighter than the minimum bend radius of 3 ft   
					tioner fluid manifold and install them in   
					(0.9 m). Do not subject hose to excessive   
					the FTS swivel inlets.   
					weight, impact, or other abuse.   
					4. Install one connector (12) between wires.   
					1. Carefully extend FTS probe (H) into the   
					
					hose section from the proportioner. Do not   
					bend or kink probe. Insert probe in major   
					volume (resin) side on systems which   
					are not 1:1 mix ratio.   
					5. Connect hose assembly cable (4) to FTS   
					cable (part of 5). Slide insulator sleeves (S)   
					over connection. Leave slack in cables as   
					stress relief, to prevent cable failure.   
					2. Connect FTS (5) to mating assembly.   
					6. Connect appropriate ground wire.   
					
					
					To Mix Manifold or   
					non-heated whip   
					hose   
					5 
					S 
					4 
					S 
					H 
					12   
					TI2684E   
					To   
					Proportioner   
					20   
					309572ZAG   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
					 
				Installation   
					2. Connect hose power wires to terminal block (C)   
					on termination box (TB). Remove box cover (D)   
					and loosen lower strain relief (E). Route wires   
					through strain relief and fully insert into terminal   
					block (A and B hose wire positions are not   
					important). Torque terminal connector screws   
					(C) to 26-30 in-lb (2.9-3.3 N•m). Fully tighten   
					strain relief screws and replace cover.   
					Connect Hoses to Proportioner   
					® 
					1. Grease with Fusion grease and connect fluid   
					hoses to proportioner fluid manifold (M). Red   
					for hardener (ISO), blue for resin (RES).   
					The manifold hose adapters (N, P) allow use   
					of 1/4 in (6.4 mm). and 3/8 in. (9.5 mm) ID   
					fluid hoses. To check adapter tightness,   
					torque 1/4 in. and 3/8 in. ID hoses to:   
					• 
					• 
					A side (N) to 14 ft-lb (19 N•m).   
					B side (P) to 20 ft-lb (27 N•m).   
					To use 1/2 in. (13 mm) ID fluid hoses,   
					remove the adapters (N, P) from the propor-   
					tioner fluid manifold and install them in the   
					FTS or 3/8 in. ID hose inlets. Torque 1/2 in.   
					ID hoses to:   
					• 
					• 
					A side (N) to 43 ft-lb (58 N•m).   
					B side (P) to 55 ft-lb (74 N•m).   
					3. Connect hose power wires to electrical splice   
					connectors (12) from proportioner or accessory   
					
					
					cable from proportioner or accessory control   
					box. Wrap connections with electrical tape.   
					M 
					N 
					M 
					P 
					12   
					NOTE: For proportioners with termination box   
					(TB), follow step 2, For proportioners with electrical   
					splice connectors (12) follow step 3.   
					3 
					4 
					T 
					4. Connect FTS cable connectors. Fully tighten   
					RTD connectors, if provided.   
					If thermocouple (non-RTD) FTS connectors are   
					provided, fully tighten connectors and slide   
					connector covers over the joint.   
					5. Check that all equipment is properly grounded.   
					See proportioner manual.   
					309572ZAG   
					21   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
					 
				Installation   
					Fluid Temperature Sensor   
					(FTS) Calibration   
					(Non-RTD Versions)   
					Protective Covering   
					1. Wrap all fluid hose connections with   
					electrical tape.   
					2. Fold FTS cable wire back on hose to   
					ensure adequate strain relief. Wrap all   
					electrical connections and cable connec-   
					tions with electrical tape to protect them   
					from pulling apart and abrasion.   
					Calibrate the FTS ONLY at initial startup   
					(the first time the unit is operated) and   
					any time the hose length changes.   
					1. Before turning on the unit, ensure all hoses   
					and cables are properly connected. To   
					ensure that the FTS in the hose is at the   
					same temperature as the heaters, keep   
					heat off and store the hose FTS near the   
					machine for several minutes.   
					2. While holding down the temperature unit   
					button (Fahrenheit - “F” or Celsius - “C”)   
					turn the proportioner main power ON.   
					3. Hold the temperature unit button until tem-   
					perature is shown on the display. The fluid   
					temperature sensor is now correctly cali-   
					brated.   
					FIG. 14   
					Leave CAN cable connector (if used)   
					accessible at whip hose joint for connec-   
					tor to the Remote Display Module Kit (if   
					ordered).   
					Check Hoses for Leaks   
					1. Pressure check hose. See proportioner   
					manual for priming instructions.   
					2. After all lines are free of air, check for   
					leaks. If there are leaks, relieve pressure   
					as instructed in proportioner manual.   
					
					
					tape to protect foam.   
					3. Tighten connections, then pressurize again   
					to ensure leaks have stopped. Relieve   
					pressure.   
					FIG. 15   
					22   
					309572ZAG   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
					 
					 
					 
				Operation   
					4. For hoses that include the standard braided   
					protective scuff cover, unroll excess cover   
					over hose and electrical connections. Tape   
					securely.   
					1. Connect air hose (3) to main air supply, if   
					equipped.   
					2. Connect to spray gun. NOTE: For best   
					
					hose connection.   
					5. For hoses that include Xtreme-Wrap pro-   
					tective scuff sleeve, pull just enough   
					excess length over hose and electrical con-   
					nections. Tape securely.   
					3. Connect whip air hose to gun air inlet if   
					equipped. See gun manual.   
					4. Follow setup, startup, and operation   
					procedures in proportioner manual.   
					NOTE: Xtreme-Wrap protective scuff sleeve   
					will shorten in dry conditions. Use only as   
					much length as necessary to cover connec-   
					tions and allow excess to remain slack.   
					Maintenance   
					Operation   
					1. Before disconnecting or repairing hoses,   
					relieve all fluid pressure and shut off electri-   
					cal power to proportioner. See proportioner   
					operation manual.   
					Do not operate a coiled hose. A coiled hose   
					creates uneven heat buildup which can result   
					in hose rupture and cause serious injury,   
					including fluid injection.   
					2. Be sure fluid is cool before disconnecting   
					hoses.   
					Maximum hose operating temperature is   
					180°F (82°C). If using hose without an FTS,   
					measure hose temperature to ensure it does   
					not exceed 180°F (82°C).   
					Instructions for Replacing   
					Individual A or B Hose   
					Before disconnecting hoses, relieve all fluid   
					pressure and shut off electrical power to pro-   
					portioner. See proportioner operation manual.   
					Hose must be properly supported to avoid   
					excessive strain due to weight, bending,   
					sharp edges, or stress caused by running   
					over a roof edge.   
					Fluids subjected to heat in confined spaces,   
					including hoses, can create a rapid rise in   
					pressure due to the thermal expansion.   
					Over-pressurization can result in equipment   
					rupture and serious injury.   
					Disconnect electrical wire from connectors   
					(12). Disconnect fluid hose and remove from   
					bundle.   
					Install new hose in bundle, wrapping around   
					other fluid hose and air hose. Connect fluid   
					
					• Open a valve to relieve the fluid   
					expansion during heating.   
					• Replace hoses proactively at regular   
					intervals based on your operating   
					conditions.   
					Wrap all connections with electrical tape, see   
					
					309572ZAG   
					23   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
					 
					 
					 
				Parts   
					Parts   
					Using 261669 Fluid Temperature Sensor (JIC to JIC fittings)   
					Whip Hose   
					12   
					Fluid Temperature Sensor   
					5a   
					5b   
					5d   
					9 
					4 
					6 
					2 
					8 
					5c   
					5e   
					3 
					WLꢀꢁꢂꢃꢄE   
					Heated Fluid Hose   
					1 
					Ref. Part   
					6 
					Description   
					
					
					Qty   
					Ref. Part   
					1 
					Description   
					HOSE, component A (ISO); see   
					tables starting on page 4   
					HOSE, component B (RES); see   
					tables starting on page 4   
					Qty   
					1 
					1 
					8 
					9 
					15B280 HOSE, whip, air; 10 ft (3 m)   
					1 
					1 
					2 
					1 
					SCUFF GUARD; included on some   
					
					3 
					4 
					5 
					5a   
					5b   
					15B295 HOSE, air; 50 ft (15.2 m)   
					24F179 HOSE, air; 25 ft (7.6 m)   
					24J523 CABLE, FTS; 50 ft (15.2 m)   
					24J524 CABLE, FTS; 25 ft (7.6 m)   
					261669 KIT, FTS, coupler   
					1 
					1 
					1 
					1 
					1 
					1 
					1 
					1 
					1 
					1 
					12 261821 CONNECTOR, electrical; on main   
					1 
					hose sections   
					13▲ 15B679 LABEL, safety, English; not shown   
					▲ 16M219 LABEL, safety, Spanish/French; not   
					shown   
					1 
					1 
					SENSOR, fluid temperature; -5 JIC   
					FITTING, FTS coupler; -6 JIC   
					▲ Replacement Danger and Warning labels, tags, and   
					5c 24V454 HOSE, air; 4.75 in. (120.65 mm)   
					5d 127596 FITTING, swivel; -6 JIC x -6 JIC, mxf   
					5e 127597 FITTING, swivel; -5 JIC x -5 JIC, mxf   
					cards are available at no cost.   
					24   
					309572ZAG   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
					 
					 
				Parts   
					Using 24M943 Fluid Temperature Sensor (NPT to NPT fittings)   
					Whip Hose   
					12   
					Fluid Temperature Sensor   
					15   
					5a   
					5b   
					9 
					4 
					6 
					2 
					15   
					8 
					5c   
					3 
					Ti19091b   
					1 
					Heated Fluid Hose   
					Ref. Part   
					Description   
					Qty   
					1 
					HOSE, component A (ISO); see   
					1 
					tables starting on page 4   
					2 
					HOSE, component B (RES); see   
					tables starting on page 4   
					1 
					3 
					4 
					5 
					15B295 HOSE, air; 50 ft (15.2 m)   
					24F179 HOSE, air; 25 ft (7.6 m)   
					24J523 CABLE, FTS; 50 ft (15.2 m)   
					24J524 CABLE, FTS; 25 ft (7.6 m)   
					24M943 KIT, FTS, coupler   
					1 
					1 
					1 
					1 
					1 
					1 
					1 
					- 
					5a   
					5b   
					5c   
					SENSOR, fluid temperature; 1/2 npt   
					FITTING, FTS coupler; (1/2 npt(f)   
					HOSE, air; 3.75 in. (95.3 mm)   
					
					
					6 
					1 
					8 
					9 
					15B280 HOSE, whip, air; 10 ft (3 m)   
					SCUFF GUARD; included on some   
					
					1 
					1 
					12 261821 CONNECTOR, electrical; on main   
					1 
					hose sections   
					13▲ 15B679 LABEL, safety, English; not shown   
					▲ 16M219 LABEL, safety, Spanish/French; not   
					shown   
					1 
					1 
					15★   
					CONNECTOR, manifold   
					4 
					▲ Replacement Danger and Warning labels, tags, and   
					cards are available at no cost.   
					★ Not included. Order connector fittings that connect to   
					the A and B component hoses. See Adapter Fit-   
					
					309572ZAG   
					25   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
					 
				Parts   
					Using 24K207 RTD 2-Component Hose Fluid Temperature Sensor   
					(JIC to JIC fittings)   
					Whip Hose   
					Fluid Temperature Sensor   
					12   
					5a   
					5b   
					5d   
					4 
					2 
					9 
					6 
					8 
					5c   
					5e   
					TI18392b   
					3 
					1 
					14   
					Heated Fluid Hose   
					Ref. Part   
					6 
					Description   
					
					
					Qty   
					Ref. Part   
					1 
					Description   
					HOSE, component A (ISO); see   
					tables starting on page 4   
					HOSE, component B (RES); see   
					tables starting on page 4   
					Qty   
					1 
					1 
					8 
					9 
					15B280 HOSE, whip, air; 10 ft (3 m)   
					1 
					1 
					2 
					1 
					SCUFF GUARD; included on some   
					
					3 
					4 
					5 
					5a   
					5b   
					15B295 HOSE, air; 50 ft (15.2 m)   
					24N450 CABLE, RTD; 50 ft (15.2 m)   
					24K207 KIT, FTS, coupler   
					SENSOR, FTS-RTD   
					1 
					1 
					1 
					1 
					1 
					1 
					1 
					1 
					12 261821 CONNECTOR, electrical; on main   
					1 
					hose sections   
					13▲ 15B679 LABEL, safety, English; not shown   
					▲ 16M219 LABEL, safety, Spanish/French; not   
					shown   
					1 
					1 
					COUPLER   
					5c 24V454 HOSE, air; 4.75 in. (120.65 mm)   
					5d 127596 FITTING, swivel; -6 JIC x -6 JIC, mxf   
					5e 127597 FITTING, swivel; -5 JIC x -5 JIC, mxf   
					14* 24N449 CABLE, CAN; 50 ft (15.2 m)   
					1 
					▲ Replacement Danger and Warning labels, tags, and   
					cards are available at no cost.   
					* 
					
					
					
					26   
					309572ZAG   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
					 
				Parts   
					Using 24M944 RTD 2-Component Hose Fluid Temperature Sensor   
					(NPT to NPT fittings)   
					Whip Hose   
					Fluid Temperature Sensor   
					12   
					15   
					5b   
					5a   
					15   
					9 
					4 
					2 
					6 
					15   
					8 
					5c   
					15   
					TI19092b   
					3 
					14   
					1 
					Heated Fluid Hose   
					Ref. Part   
					Description   
					Qty   
					Ref. Part   
					1 
					Description   
					HOSE, component A (ISO); see   
					tables starting on page 4   
					HOSE, component B (RES); see   
					tables starting on page 4   
					Qty   
					8 
					9 
					15B280 HOSE, whip, air; 10 ft (3 m)   
					1 
					1 
					1 
					SCUFF GUARD; included on some   
					
					2 
					1 
					12 261821 CONNECTOR, electrical; on main   
					1 
					hose sections   
					3 
					4 
					5 
					5a   
					5b   
					5c   
					15B295 HOSE, air; 50 ft (15.2 m)   
					24N450 CABLE, RTD; 50 ft (15.2 m)   
					24M944 KIT, FTS, coupler   
					SENSOR, FTS-RTD   
					1 
					1 
					1 
					1 
					1 
					13▲ 15B679 LABEL, safety, English; not shown   
					▲ 16M219 LABEL, safety, Spanish/French; not   
					shown   
					14* 24N449 CABLE, CAN; 50 ft (15.2 m)   
					15★   
					1 
					1 
					1 
					4 
					COUPLER   
					HOSE, air; 3.75 in. (95.3 mm)   
					CONNECTOR, manifold   
					- 
					6 
					
					
					1 
					▲ Replacement Danger and Warning labels, tags, and   
					cards are available at no cost.   
					* 
					
					
					
					★ Not included. Order connector fittings that connect to   
					the A and B component hoses. See Adapter Fit-   
					
					309572ZAG   
					27   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
					 
				Parts   
					Using 261670 Fluid Temperature Sensor (JIC to NPT fittings)   
					Fluid Temperature Sensor   
					5a   
					5 
					5b   
					Heated Fluid Hose   
					4 
					1 
					5d   
					5c   
					12   
					2 
					TI2684E   
					Ref. Part   
					Description   
					Qty   
					Ref. Part   
					Description   
					Qty   
					5c   
					5d   
					12   
					117506 . SWIVEL; 1/4 npt(m) x -6 JIC (f)   
					157705 . SWIVEL; 1/4 npt(m) x 3/8 npsm   
					261821 CONNECTOR, electrical; on main   
					hose sections   
					1 
					1 
					1 
					1 
					HOSE, component A (ISO); see   
					1 
					tables starting on page 4   
					2 
					HOSE, component B (RES); see   
					tables starting on page 4   
					24J523 CABLE, FTS; 50 ft (15.2 m)   
					24J524 CABLE, FTS; 25 ft (7.6 m)   
					261670 FLUID TEMPERATURE SENSOR;   
					includes items 5a-5d   
					1 
					13▲ 15B679 LABEL, safety, English; not shown   
					1 
					1 
					4 
					5 
					1 
					1 
					1 
					▲ 
					16M219 LABEL, safety, French/Spanish;   
					not shown   
					5a   
					5b   
					156823 . SWIVEL; 1/4 npt (m x 1/4 npsm   
					117595 . SWIVEL; 1/4 npt(m) x -5 JIC (f)   
					1 
					1 
					▲ Replacement Danger and Warning labels, tags, and   
					cards are available at no cost.   
					28   
					309572ZAG   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
					 
				Parts   
					Install as follows:   
					15F144 Hose Wire Jumper   
					Use the 15F144 Hose Wire Jumper to heat   
					only the major volume hose, in a wide ratio   
					system.   
					This hose must be used with an FTS and   
					cable to provide grounding.   
					To build one complete 50 ft single side heated   
					hose bundle, order the following parts:   
					1. Wrap hose wire jumper (100) around resin   
					hose (101) in a spiral fashion.   
					Ref. Part   
					Description   
					Qty.   
					2. Connect resin hose wire (101a) to other   
					side of Power-Lock connector (100a); see   
					
					100 15F144 JUMPER, hose wire   
					101   
					1 
					1 
					HOSE, resin, heated; 50 ft   
					(15.2 m) minimum; see tables   
					starting on page 4   
					3. Wrap FTS cable (102) around resin hose   
					(101) in a spiral fashion.   
					102 24J523 CABLE, FTS   
					104 261670 FLUID TEMPERATURE   
					SENSOR; see page 24   
					1 
					1 
					105 pur-   
					chase   
					locally   
					HOSE, hardener, unheated; 50   
					ft (15.2 m) minimum; customer   
					supplied   
					1 
					4. Twist hoses (101 and 105) together to pro-   
					vide strain relief.   
					106 pur-   
					CONNECTORS, fluid; as   
					required to complete assem-   
					bly; not shown   
					as   
					req’d   
					
					(101). Connect hoses, electrical connec-   
					tors, and cables; see Connect Heated   
					
					chase   
					locally   
					6. Install one -Lock connector (100a) between   
					
					
					
					309572ZAG   
					29   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
					 
					 
				Parts   
					8. Install whip hose and gun. Ensure that gun   
					is grounded.   
					Some previous models include trans-   
					formers with tap settings.   
					9. Connect hoses to proportioner.   
					Set transformer wire taps, using the following   
					table. Transformer tap wire connections vary   
					depending on length of heated hose. See pro-   
					portioner operation manual for further informa-   
					tion. Verify that tap wire connections are   
					correct.   
					
					
					Single Side Heated Tap Terminal   
					Hose Length, ft (m) Label (ft)   
					50 (15.2)   
					50   
					100 (30.5)   
					150 (45.7)   
					200 (61.0)   
					250 (76.2)   
					300 (91.5)   
					350 (106.8)   
					400 (122.0)   
					50   
					100   
					100   
					150   
					150   
					200   
					200   
					105   
					102   
					FTS   
					101a   
					100   
					100a   
					101   
					100   
					100a   
					101a   
					TI5872D   
					30   
					309572ZAG   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Accessories   
					Accessories   
					Scuff Guard   
					Use to keep hose clean and protect it from   
					damage.   
					Part   
					Description   
					246077   
					7 ft (2.1 m) braided polyester   
					mesh. For whip hose. Fold back   
					over itself for easy installation.   
					246078   
					246805   
					50 ft (15.2 m) braided polyester   
					mesh.   
					Fold back over itself for easy   
					installation.   
					25 ft (7.6 m) braided polyester   
					mesh.   
					Fold back over itself for easy   
					installation.   
					246456   
					24T243   
					50 ft (15.2 m) polyethylene bag.   
					Inflate with air for easy installation.   
					8 ft (2.4 m) Xtreme-Wrap abra-   
					sion-resistant woven nylon sleeve   
					for whip hose   
					24T244   
					55 ft (16.8 m) Xtreme-Wrap abra-   
					sion-resistant woven nylon sleeve   
					309572ZAG   
					31   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
					 
					 
				Technical Data   
					Technical Data   
					Power-Lock Heated Hose   
					US   
					Metric   
					0.9 MPa, 9 bar   
					82°C   
					Maximum Air Working Pressure   
					Maximum Fluid Operating Temperature   
					Wetted Parts   
					130 psi   
					180°F   
					Nylon, Zinc-Plated Carbon Steel, 303 Stainless Steel   
					Total Heating Load (2 Hoses)   
					1/4 in. diameter:   
					3/8 in. diameter:   
					11 watts/foot   
					13 watts/foot   
					15 watts/foot   
					36 watts/meter   
					43 watts/meter   
					49 watts/meter   
					1/2 in. diameter:   
					Whip Hose Maximum Fluid Working Pressure   
					246050*   
					246055*   
					246056   
					249586   
					258701   
					2000 psi   
					14 MPa, 138 bar   
					24 MPa, 241 bar   
					24 MPa, 241 bar   
					14 MPa, 138 bar   
					35 MPa, 345 bar   
					3500 psi   
					3500 psi   
					2000 psi   
					5000 psi   
					Standard 2 Component Hose Maximum Fluid Working Pressure   
					246045   
					246046   
					246047   
					246048   
					246049   
					246052   
					246053   
					246054   
					246074   
					246075   
					246076   
					246678   
					246679   
					249587   
					249588   
					256548   
					256549   
					261328   
					261332   
					261335   
					262203   
					24Y549*   
					24Y678*   
					24Y679*   
					2000 psi   
					2000 psi   
					2000 psi   
					2000 psi   
					2000 psi   
					3500 psi   
					3500 psi   
					3500 psi   
					2000 psi   
					2000 psi   
					2000 psi   
					2000 psi   
					3500 psi   
					2000 psi   
					3500 psi   
					3500 psi   
					2000 psi   
					2000 psi   
					5000 psi   
					3500 psi   
					5000 psi   
					2000 psi   
					2000 psi   
					3500 psi   
					14 MPa, 138 bar   
					14 MPa, 138 bar   
					14 MPa, 138 bar   
					14 MPa, 138 bar   
					14 MPa, 138 bar   
					24 MPa, 241 bar   
					24 MPa, 241 bar   
					24 MPa, 241 bar   
					14 MPa, 138 bar   
					14 MPa, 138 bar   
					14 MPa, 138 bar   
					14 MPa, 138 bar   
					24 MPa, 241 bar   
					14 MPa, 138 bar   
					24 MPa, 241 bar   
					24 MPa, 241 bar   
					14 MPa, 138 bar   
					14 MPa, 138 bar   
					35 MPa, 345 bar   
					24 MPa, 241 bar   
					35 MPa, 345 bar   
					14 MPa, 138 bar   
					14 MPa, 138 bar   
					24 MPa, 241 bar   
					32   
					309572ZAG   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
					 
				Technical Data   
					Power-Lock Heated Hose   
					US   
					RTD 2 Component Hose (For GCA Reactors) Maximum Fluid Working Pressure   
					Metric   
					24K240   
					24K241   
					24K394   
					24K395   
					24N000   
					24N001   
					24N002   
					24N003   
					24T839   
					24U743   
					24Y240*   
					24Y241*   
					24Y394*   
					24Y395*   
					2000 psi   
					3500 psi   
					2000 psi   
					3500 psi   
					2000 psi   
					2000 psi   
					3500 psi   
					3500 psi   
					2000 psi   
					3500 psi   
					2000 psi   
					3500 psi   
					2000 psi   
					3500 psi   
					14 MPa, 138 bar   
					24 MPa, 241 bar   
					14 MPa, 138 bar   
					24 MPa, 241 bar   
					14 MPa, 138 bar   
					14 MPa, 138 bar   
					24 MPa, 241 bar   
					24 MPa, 241 bar   
					14 MPa, 138 bar   
					24 MPa, 241 bar   
					14 MPa, 138 bar   
					24 MPa, 241 bar   
					14 MPa, 138 bar   
					24 MPa, 241 bar   
					Airless 2 Component Hose Maximum Fluid Working Pressure   
					248907   
					248908   
					262727   
					262728   
					262730   
					5000 psi   
					5000 psi   
					5000 psi   
					5000 psi   
					5000 psi   
					35 MPa, 345 bar   
					35 MPa, 345 bar   
					35 MPa, 345 bar   
					35 MPa, 345 bar   
					35 MPa, 345 bar   
					Custom Application 2 Component Hose Maximum Fluid Working Pressure   
					247164   
					255089   
					261336   
					261337   
					3500 psi   
					2000 psi   
					3500 psi   
					3500 psi   
					3500 psi   
					24 MPa, 241 bar   
					14 MPa, 138 bar   
					24 MPa, 241 bar   
					24 MPa, 241 bar   
					24 MPa, 241 bar   
					24N524   
					FTS Maximum Fluid Working Pressure   
					261669   
					261670   
					24M943   
					5000 psi   
					5000 psi   
					7250 psi   
					35 MPa, 345 bar   
					35 MPa, 345 bar   
					50 MPa, 500 bar   
					FTS (For GCA Systems) Maximum Fluid Working Pressure   
					24K207   
					24M944   
					5000 psi   
					7250 psi   
					35 MPa, 345 bar   
					50 MPa, 500 bar   
					* 
					These models include the Xtreme-Wrap Scuff   
					Guard.   
					309572ZAG   
					33   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Graco Standard Warranty   
					Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in   
					material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty   
					published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by   
					Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written   
					recommendations.   
					This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty   
					installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of   
					non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with   
					structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or   
					maintenance of structures, accessories, equipment or materials not supplied by Graco.   
					This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of   
					the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned   
					to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs   
					will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.   
					THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT   
					LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.   
					Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy   
					(including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or   
					consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.   
					GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A   
					PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT   
					MANUFACTURED BY GRACO. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to   
					the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these   
					warranties.   
					In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or   
					the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the   
					negligence of Graco, or otherwise.   
					FOR GRACO CANADA CUSTOMERS   
					The Parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into,   
					given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la   
					rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés, à la suite   
					de ou en rapport, directement ou indirectement, avec les procédures concernées.   
					Graco Information   
					
					TO PLACE AN ORDER, contact your Graco distributor, or call this number to identify the distrib-   
					utor closest to you: 1-800-328-0211 Toll Free   
					612-623-6921   
					612-378-3505 Fax   
					All written and visual data contained in this document reflects the latest product information available at the time of publication.   
					Graco reserves the right to make changes at any time without notice.   
					Original instructions. This manual contains English. MM 309572   
					Graco Headquarters: Minneapolis   
					International Offices: Belgium, China, Japan, Korea   
					GRACO INC. AND SUBSIDIARIES • P.O. BOX 1441 • MINNEAPOLIS MN 55440-1441 • USA   
					Copyright 2002, Graco Inc. All Graco manufacturing locations are registered to ISO 9001.   
					
					Revision ZAG, June 2015   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
					 
					 
				 |