Kit Instructions/Parts
313840G
EN
®
DataTrak Kits
For providing pump diagnostics and material usage information for diaphragm pumps.
Conversion Kits - DataTrak with Pulse Count and Runaway Protection
®
Husky 1050 - 24B777, 24B784, and 24B793
®
Husky 3300 - 24K861 and 24K862
Conversion Kits - DataTrak with Pulse Count
®
®
Husky 1050 and Husky 3300 - 24B794 and 24B795
Replacement Parts Kits 24B771, 24B772, 24B796, 24B798, 24K863, and 24K864
Model 24B777 shown
Important Safety Instructions
Read all warnings and instructions
®
®
in the Husky 1050 or Husky 3300
Air-Operated Diaphragm Pump
manuals. Save all instructions.
ti14052a
Download from Www.Somanuals.com. All Manuals Search And Download.
DataTrak Kits
DataTrak Kits
Conversion Kits
Use to add data monitoring capabilities to an existing pump.
Data Monitoring
Pulse
Count and
Husky
1050
Husky
3300
Diaphragm
Pump Material Protection Count
Runaway Pulse
24B777
24B795
24B784
24B794
24B793
24B794
24K861
24B795
24K862
24B794
✔*
Aluminum
✔
✔*
Polypropylene
✔
✔*
Conductive
Polypropylene
✔
* Kit includes replacement air valve compatible with solenoid.
Replacement Part Kits
Aluminum
Husky
1050A
Husky
3300A
Description
Solenoid/Reed Switch Assembly
(pulse count and runaway protection)
24B772
24B798
24K864
24B798
Reed Switch Assembly
(pulse count only)
Polypropylene and Conductive Polypropylene
Husky1050P Husky
or 1050C
24B771
24B796
3300P
Description
Solenoid/Reed Switch Assembly
(pulse count and runaway protection)
24K863
24B796
Reed Switch Assembly
(pulse count only)
313840G
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
Installation
4. Select the Diagnostic Codes card that matches the
operator’s preferred language. Insert it in the inside
of the DataTrak cover for quick reference.
SPECIAL CONDITIONS FOR SAFE USE
Equipment must comply with the following
conditions to avoid a hazardous condition
which can cause fire or explosion.
•
All label and marking material must be
cleaned with a damp cloth (or equiva-
lent).
•
The electronic monitoring system is
required to be grounded. See Ground-
ing instructions in your pump operation
manual.
ti14223a
5. DataTrak with runaway protection: Attach the sole-
noid (S) and bracket (4d) to the air valve. Use the
same screws (4c) that attach the air valve to the
manifold, as shown.
Prepare to Install
1. Relieve the pressure. Follow instructions in your
Operation manual.
2. Disconnect the air line to the pump.
4c
4d
Install the Kit
1. Mount the bracket
1
to the wall. Use
approximately
3/8 in. bolts or
screws.
S
2. Install the DataTrak
module (1) on the
bracket.
ti14058a
ti14055a
3. Conversion Kits include a new air valve that is com-
patible with the solenoid. Remove the old air valve
and gasket from the pump, and install the replace-
ment air valve and gasket.
4
313840G
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
6. Use the screw provided to attach the reed switch
just behind the air inlet. Remove the muffler, if
a. The DataTrak pump icon should move when the
air motor changes direction.
needed, for easier access. Rotate the air inlet fitting
as needed so the wrench flat clears the reed switch.
b. The Grand Totalizer and Batch Totalizer should
advance.
4. DataTrak with runaway protection: Check for proper
runaway operation.
a. Run the air motor at a speed faster than the run-
away limit.
b. After 5 consecutive cycles,
the DataTrak should stop the
pump and display the run-
away diagnostic screen.
ti14056a
7. Connect the DataTrak cable to the 5-pin connector
on the reed switch. Reconnect the air line to the
motor.
c. To reset, turn the pressure off, then push
on the DataTrak module.
d. After resetting, turn on the air supply. The air
motor should run. Shut off the air until ready to
pump.
5-pin
connector
NOTE: If the DataTrak does not reset, turn air pressure
down, then use a screwdriver to push the solenoid
release button on the side of the air valve.
ti14054a
8. Secure DataTrack data cable. A plastic spiral con-
duit is provided to help prevent chafing.
ti14263a
Check DataTrak Operation
1. Enable runaway
and set the runaway limit. See
2. Run the air motor at a speed slower than the run-
away limit.
3. Check for proper reed switch operation.
313840G
5
Download from Www.Somanuals.com. All Manuals Search And Download.
DataTrak Controls and Indicators
DataTrak Controls and Indicators
Key
AA Runaway Limit, in cycles per minute (user settable;
00=OFF)
AB Displacement (user settable)
PF Prime/Flush Key (Enables Prime/Flush mode. While in
Prime/Flush mode, runaway protection is disabled and the
batch totalizer [BT] will not count.) LED will flash while in
Prime/Flush mode.
/min,
AC Flow Rate Units (user settable to
gpm [US],
RK Reset Key (Resets faults. Press and hold for 3 seconds to
clear the batch totalizer.) Push to toggle between flow rate
and cycle rate.
CF Cycle/Flow Rate
BT Batch Totalizer (resettable)
gpm [Imperial], oz/min [US], oz/min [Imperial], l/min, or
cc/min)
AD LED (fault indicator when flashing)
AE Display
GT Grand Totalizer (not resettable)
GT
Run Mode
AE, see details at right
RK
PF
ti8622b
CF
BT
TI11883a
AD
Setup Mode
AC
AB
PF
RK
ti8623b
AA
Fig. 1. DataTrak Controls and Indicators
6
313840G
Download from Www.Somanuals.com. All Manuals Search And Download.
DataTrak Operation
DataTrak Operation
NOTE: The display (AE) will turn off after 1 minute to
save battery life. Press any key to wake up the display.
Run Mode
NOTE: DataTrak is factory set to 685 cc/cycle. This set-
ting is accurate for pumping water at a medium speed
on a Husky 1050 pump (approximately 20 gpm). The
DataTrak can be calibrated for use with a different Husky
model, for greater accuracy, for different pump speeds,
or for different viscosity fluids. See Calibration Proce-
Runaway
1. If pump runaway occurs, the runaway solenoid will
actuate, stopping the pump. The LED (AD) will flash
and the display (AE) will indicate a runaway condi-
tion. The display will cycle through four instruction
screens.
Setup Mode
1. See Fig. 1. Press and hold
Setup menu appears.
for 5 seconds until
2. To enter settings for flow rate units and displace-
ment, press to change the value, then to
save the value and move the cursor to the next data
field.
3. To enter setting for runaway (if equipped), enter
pump speed in cycles/min. The exact setting will
vary by pump speed and viscosity of fluid. Choose a
setting that is just above the fastest speed expected
during normal operation.
2. To reset the runaway solenoid, close the master air
valve. Wait for air to completely bleed off the air
motor.
3. Press
to clear the diagnostic code and reset the
NOTE: Set the value to zero to disable runaway protec-
tion or if your pump is not equipped with a runaway pro-
tection solenoid.
runaway solenoid.
4. Open master air valve to restart pump.
NOTE: A flashing LED indicates an error that must be
addressed. The Runaway mode will not stop a runaway
pump while the LED is flashing.
4. Move the cursor to the last field, then press
once more to exit Setup mode.
313840G
7
Download from Www.Somanuals.com. All Manuals Search And Download.
DataTrak Operation
NOTE: If the DataTrak does not reset, use a screwdriver
to push the solenoid release button on the side of the air
valve.
Counter/Totalizer
To reset the totalizer, press any key to wake up the dis-
play, then press and hold
for 3 seconds.
•
•
•
If AC is set to gallons or ounces, BT and GT dis-
play gallons.
If AC is set to liters or cc, BT and GT display
liters.
If AC is set to cycles, BT and GT display cycles.
NOTE: Press
to toggle between flow rate units and
cycles. A letter under the BT display indicates that both
BT and GT are displaying gallons (g) or liters (l). No let-
ter means both BT and GT are displaying cycles.
ti14263a
5. If the solenoid doesn’t actuate:
Display
a. Close the master air valve to stop the pump.
The display will show the Service Component 1
See Fig. 1. The display (AE) will turn off after 1 minute of
inactivity in Run mode or 3 minutes in Setup mode.
Press any key to wake up the display.
screen.
NOTE: DataTrak will continue to count cycles when dis-
play is off.
NOTE: The display (AE) may turn off if a high-level static
discharge is applied to the DataTrak. Press any key to
wake up the display.
NOTE: To disable runaway monitoring, go to setup
mode and set runaway value to 0 (zero). See Fig. 1.
Diagnostics
DataTrak can diagnose several problems with the pump.
When the monitor detects a problem, the LED (AD, Fig.
1) will flash and a diagnostic code will appear on the dis-
Prime/Flush
1. See Fig. 1. To enter Prime/Flush mode, press any
key to wake up the display, then press
Prime/Flush symbol will appear in the display and
. The
To acknowledge the diagnosis and return to the normal
operating screen, press
once to wake up the display,
and once more to clear the diagnostic code screen.
the LED will flash
.
2. While in Prime/Flush mode, runaway protection is
disabled and the batch totalizer (BT) will not count.
3. To exit Prime/Flush mode, press any key to wake up
the display, then press
. The Prime/Flush sym-
bol will disappear from the display and the LED will
stop flashing.
8
313840G
Download from Www.Somanuals.com. All Manuals Search And Download.
DataTrak Operation
Calibration Procedure
1. Press and hold
appears.
for 5 seconds until Setup menu
2. Press
cycles/min.
once. Change flow rate units to
3. Return to Run Screen. Press and hold
seconds to reset batch totalizer.
for three
4. Dispense fluid from pump into a graduated con-
tainer.
5. Convert the actual volume dispensed to cubic centi-
meters (cc). See conversion chart.
Units Measured Multiply by
To get
Gallons (U.S.)
Gallons (Imp)
Liters
3785
4546
1000
946
29.57
28.41
16.39
28,317
473
cc
cc
cc
cc
cc
cc
cc
cc
cc
cc
Quarts
Ounces (U.S.)
Ounces (Imp)
Cubic inches
Cubic feet
Pints
cc
1
6. Divide the actual volume dispensed (cc) by the num-
ber of cycles indicated on the DataTrak batch total-
izer display.
7. Press
to enter the Setup screen. Enter the
number from Step 6 in field 2 of the Setup screen.
313840G
9
Download from Www.Somanuals.com. All Manuals Search And Download.
DataTrak Operation
Table 1: Diagnostic Codes
Symbol
Code
Code Name
Diagnosis
Cause
Runaway
Pump running faster than Increased air pressure.
set runaway limit.
Increased fluid output.
Exhausted fluid supply.
E-3 Low Battery
E--4 Service
Battery voltage too low to Low battery. Replace battery;
stop runaway.
Problem with stopping
Damaged solenoid.
Component 1 runaway.
Damaged valve carriage.
Runaway protection may be
enabled with pump that is not
equipped with a runaway sole-
noid valve. Enter setup screen
and disable runaway protec-
tion.
E-4 Disconnected Solenoid is disconnected. Solenoid unplugged.
Solenoid
Damaged solenoid wires.
E-6 Blown Fuse
Fuse is blown. Replace
Faulty solenoid or solenoid
wiring.
Extreme temperatures (above
140°F [60°C]).
Runaway protection may be
enabled with pump that is not
equipped with a runaway sole-
noid valve. Enter setup screen
and disable runaway protec-
tion.
10
313840G
Download from Www.Somanuals.com. All Manuals Search And Download.
DataTrak Operation
Replace DataTrak Battery or Fuse
3. Remove two screws on back of module to access
battery.
4. Disconnect the used battery and replace with an
approved battery. See Fig. 4.
To reduce the risk of fire and explosion, the battery
and fuse must be replaced in a non-hazardous loca-
tion.
Table 2. Approved Batteries
Use only an approved replacement battery, shown in
Table 2, and an approved fuse, shown in Table 3. Use
of an unapproved battery or fuse will void Graco’s war-
ranty and Intertek and Ex approvals.
Energizer alkaline # 522
Varta alkaline # 4922
Ultralife lithium # U9V
Duracell alkaline # MN1604
Replace Battery
1. Unscrew cable from the reed switch assembly. See
Fig. 2.
ti14054a
Fig. 2. Disconnect DataTrak
2. Remove DataTrak module from bracket. See Fig. 3.
Take module to a non-hazardous location.
ti14053a
Fig. 3. Remove DataTrak
313840G
11
Download from Www.Somanuals.com. All Manuals Search And Download.
DataTrak Operation
Replace Fuse
Table 3. Approved Fuses
DataTrak Part
Fuse
1. Remove the screw, metal strap, and plastic holder.
Number
Series*
Required
2. Pull the fuse away from the board.
3. Replace with a new fuse.
A or B
C and later
A
24C580
24V216
24C580
24V216
289822
All other part
numbers
B and later
* Fig. 4 shows where to find the Series letter.
Solenoid Cable
Connection
Fuse
SensorCable
Connection
Series Letter
(last digit of code)
ti11994b
Battery
Fig. 4. DataTrak Battery and Fuse Location
12
313840G
Download from Www.Somanuals.com. All Manuals Search And Download.
DataTrak Operation
313840G
13
Download from Www.Somanuals.com. All Manuals Search And Download.
Parts
Parts
Conversion Kits, Cycle Count and Runaway Protection
Husky 1050 - 24B777 (Aluminum), 24B784 (Polypropylene), and 24B793 (Conductive Polypropylene)
Husky 3300 - 24K861 (Aluminum) and 24K862 (Polypropylene)
Aluminum
6c
6a
1
2
3
6b
ti14225a
Plastic
Plastic
Aluminum
6c
6a
4a
4d
4c
4d
4b
6b
4c
ti14052a
ti14226a
14
313840G
Download from Www.Somanuals.com. All Manuals Search And Download.
Parts
Ref.
Ref.
No. Part No. Description
Qty
No. Part No. Description
Qty
6
AIR VALVE, kit
(includes Parts 6a-6c)
1
1
-----
DATATRAK module
fuse replacement information)
1
24B767 Husky 1050 Aluminum
2
3
4
-----
-----
CABLE
BRACKET, wall
1
1
1
24B774 Husky 1050 Polypropylene
24B776 Husky 1050 Conductive
Polypropylene
SOLENOID/REED SWITCH, kit
(includes Parts 4a-4d)
24K856 Husky 3300 Aluminum
24B771 Husky 1050 plastic air valve
24B772 Husky 1050 aluminum air valve
24K863 Husky 3300 plastic air valve
24K864 Husky 3300 aluminum air valve
24K858 Husky 3300 Polypropylene
6a -----
6b -----
6c -----
VALVE, air, smart
GASKET, air valve
FASTENERS, air valve
1
1
4
M6 x 25 screw, Aluminum air valve
M6 hex nut, Plastic air valve
7▲ 15V262 LABEL, warning (not shown)
4a -----
4b -----
REED SWITCH with SOLENOID
1
1
SCREW, reed switch
8-32 x 1.50 taptite, aluminum air
valve
1
1
8▲ 16A098 CARD, reference, language (not
6-19 x 1-5/8 plastite, plastic air valve
shown)
4c -----
4d -----
BRACKET, solenoid
FASTENER, solenoid
M6 x 25 screw, aluminum air valve
M6 hex nut, plastic air valve
1
2
▲ Replacement Warning labels, signs, tags, and cards
are available at no cost.
----- Not sold separately.
313840G
15
Download from Www.Somanuals.com. All Manuals Search And Download.
Parts
Conversion Kits, Cycle Count Only
Husky 1050 and Husky 3300 - 24B794 (Aluminum) and 24B795 (Polypropylene and Conductive
Polypropylene)
1
3
2
5a
ti14224a
5b
Ref.
No. Part No. Description
Qty
1
-----
DATATRAK module
1
and fuse replacement information)
2
3
5
-----
-----
CABLE, CAN
BRACKET, wall
1
1
1
REED SWITCH, kit
(includes Parts 5a-5b)
24B796 Plastic air valve
24B798 Aluminum air valve
5a
5b
-----
-----
REED SWITCH
1
1
SCREW, reed switch
8-32 x 1.50 taptite, aluminum air
valve
6-19 x 1-5/8 plastite, plastic air
valve
6▲
7▲
15V262 LABEL, warning (not shown)
1
1
16A098 CARD, reference, language (not
shown)
▲ Replacement Warning labels, signs, tags, and cards
are available at no cost.
16
313840G
Download from Www.Somanuals.com. All Manuals Search And Download.
Parts
Replacement Kits
Solenoid/Reed Switch
Husky Husky
1050
3300
Air Valve Material
Includes
Plastic
Reed switch and solenoid (4a),
bracket (4c), and fasteners (4b, 4d)
24B771 24K863
24B772 24K864
Aluminum
Reed Switch
Husky
1050 or
Husky
3300
Air Valve Material
Includes
Plastic
24B796
24B798
Reed switch (5a)
and fastener (5b)
Aluminum
313840G
17
Download from Www.Somanuals.com. All Manuals Search And Download.
Graco Standard Warranty
Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in
material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty
published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by
Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written
recommendations.
This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty
installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of
non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with
structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or
maintenance of structures, accessories, equipment or materials not supplied by Graco.
This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of
the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned
to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will
be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.
THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED
TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.
Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy
(including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or
consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.
GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT
MANUFACTURED BY GRACO. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to
the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these
warranties.
In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or
the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the
negligence of Graco, or otherwise.
FOR GRACO CANADA CUSTOMERS
The Parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into,
given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la
rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés, à la suite
de ou en rapport, directement ou indirectement, avec les procédures concernées.
Graco Information
For the latest information about Graco products, visit www.graco.com.
For patent information, see www.graco.com/patents.
TO PLACE AN ORDER, contact your Graco distributor or call to identify the nearest distributor.
Phone: 612-623-6921 or Toll Free: 1-800-328-0211 Fax: 612-378-3505
All written and visual data contained in this document reflects the latest product information available at the time of publication.
Graco reserves the right to make changes at any time without notice.
Original instructions.This manual contains English. MM 313840
Graco Headquarters: Minneapolis
International Offices: Belgium, China, Japan, Korea
GRACO INC. AND SUBSIDIARIES • P.O. BOX 1441 • MINNEAPOLIS MN 55440-1441 • USA
Copyright 2009, Graco Inc. All Graco manufacturing locations are registered to ISO 9001.
Revision G, July 2014
Download from Www.Somanuals.com. All Manuals Search And Download.
|