Graco Microscope Magnifier 24B771 User Manual

Kit Instructions/Parts  
313840G  
EN  
®
DataTrak Kits  
For providing pump diagnostics and material usage information for diaphragm pumps.  
Conversion Kits - DataTrak with Pulse Count and Runaway Protection  
®
Husky 1050 - 24B777, 24B784, and 24B793  
®
Husky 3300 - 24K861 and 24K862  
Conversion Kits - DataTrak with Pulse Count  
®
®
Husky 1050 and Husky 3300 - 24B794 and 24B795  
Replacement Parts Kits 24B771, 24B772, 24B796, 24B798, 24K863, and 24K864  
See page 3 for model information, including agency approvals.  
Model 24B777 shown  
Important Safety Instructions  
Read all warnings and instructions  
®
®
in the Husky 1050 or Husky 3300  
Air-Operated Diaphragm Pump  
manuals. Save all instructions.  
ti14052a  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DataTrak Kits  
DataTrak Kits  
Conversion Kits  
Use to add data monitoring capabilities to an existing pump.  
Data Monitoring  
Pulse  
Count and  
Husky  
1050  
Husky  
3300  
Diaphragm  
Pump Material Protection Count  
Runaway Pulse  
24B777  
24B795  
24B784  
24B794  
24B793  
24B794  
24K861  
24B795  
24K862  
24B794  
*  
Aluminum  
*  
Polypropylene  
*  
Conductive  
Polypropylene  
* Kit includes replacement air valve compatible with solenoid.  
Replacement Part Kits  
Aluminum  
Husky  
1050A  
Husky  
3300A  
Description  
Solenoid/Reed Switch Assembly  
(pulse count and runaway protection)  
24B772  
24B798  
24K864  
24B798  
Reed Switch Assembly  
(pulse count only)  
Polypropylene and Conductive Polypropylene  
Husky1050P Husky  
or 1050C  
24B771  
24B796  
3300P  
Description  
Solenoid/Reed Switch Assembly  
(pulse count and runaway protection)  
24K863  
24B796  
Reed Switch Assembly  
(pulse count only)  
313840G  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Installation  
Installation  
4. Select the Diagnostic Codes card that matches the  
operator’s preferred language. Insert it in the inside  
of the DataTrak cover for quick reference.  
WARNING  
SPECIAL CONDITIONS FOR SAFE USE  
Equipment must comply with the following  
conditions to avoid a hazardous condition  
which can cause fire or explosion.  
All label and marking material must be  
cleaned with a damp cloth (or equiva-  
lent).  
The electronic monitoring system is  
required to be grounded. See Ground-  
ing instructions in your pump operation  
manual.  
ti14223a  
5. DataTrak with runaway protection: Attach the sole-  
noid (S) and bracket (4d) to the air valve. Use the  
same screws (4c) that attach the air valve to the  
manifold, as shown.  
Prepare to Install  
1. Relieve the pressure. Follow instructions in your  
Operation manual.  
2. Disconnect the air line to the pump.  
4c  
4d  
Install the Kit  
1. Mount the bracket  
1
to the wall. Use  
approximately  
3/8 in. bolts or  
screws.  
S
2. Install the DataTrak  
module (1) on the  
bracket.  
ti14058a  
ti14055a  
3. Conversion Kits include a new air valve that is com-  
patible with the solenoid. Remove the old air valve  
and gasket from the pump, and install the replace-  
ment air valve and gasket.  
4
313840G  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Installation  
6. Use the screw provided to attach the reed switch  
just behind the air inlet. Remove the muffler, if  
a. The DataTrak pump icon should move when the  
air motor changes direction.  
needed, for easier access. Rotate the air inlet fitting  
as needed so the wrench flat clears the reed switch.  
b. The Grand Totalizer and Batch Totalizer should  
advance.  
4. DataTrak with runaway protection: Check for proper  
runaway operation.  
a. Run the air motor at a speed faster than the run-  
away limit.  
b. After 5 consecutive cycles,  
the DataTrak should stop the  
pump and display the run-  
away diagnostic screen.  
ti14056a  
7. Connect the DataTrak cable to the 5-pin connector  
on the reed switch. Reconnect the air line to the  
motor.  
c. To reset, turn the pressure off, then push  
on the DataTrak module.  
d. After resetting, turn on the air supply. The air  
motor should run. Shut off the air until ready to  
pump.  
5-pin  
connector  
NOTE: If the DataTrak does not reset, turn air pressure  
down, then use a screwdriver to push the solenoid  
release button on the side of the air valve.  
ti14054a  
8. Secure DataTrack data cable. A plastic spiral con-  
duit is provided to help prevent chafing.  
ti14263a  
5. Configure the DataTrak as needed. See page 7.  
Check DataTrak Operation  
1. Enable runaway  
and set the runaway limit. See  
2. Run the air motor at a speed slower than the run-  
away limit.  
3. Check for proper reed switch operation.  
313840G  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
DataTrak Controls and Indicators  
DataTrak Controls and Indicators  
Key  
AA Runaway Limit, in cycles per minute (user settable;  
00=OFF)  
AB Displacement (user settable)  
PF Prime/Flush Key (Enables Prime/Flush mode. While in  
Prime/Flush mode, runaway protection is disabled and the  
batch totalizer [BT] will not count.) LED will flash while in  
Prime/Flush mode.  
/min,  
AC Flow Rate Units (user settable to  
gpm [US],  
RK Reset Key (Resets faults. Press and hold for 3 seconds to  
clear the batch totalizer.) Push to toggle between flow rate  
and cycle rate.  
CF Cycle/Flow Rate  
BT Batch Totalizer (resettable)  
gpm [Imperial], oz/min [US], oz/min [Imperial], l/min, or  
cc/min)  
AD LED (fault indicator when flashing)  
AE Display  
GT Grand Totalizer (not resettable)  
GT  
Run Mode  
AE, see details at right  
RK  
PF  
ti8622b  
CF  
BT  
TI11883a  
AD  
Setup Mode  
AC  
AB  
PF  
RK  
ti8623b  
AA  
Fig. 1. DataTrak Controls and Indicators  
6
313840G  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
DataTrak Operation  
DataTrak Operation  
NOTE: The display (AE) will turn off after 1 minute to  
save battery life. Press any key to wake up the display.  
Run Mode  
NOTE: DataTrak is factory set to 685 cc/cycle. This set-  
ting is accurate for pumping water at a medium speed  
on a Husky 1050 pump (approximately 20 gpm). The  
DataTrak can be calibrated for use with a different Husky  
model, for greater accuracy, for different pump speeds,  
or for different viscosity fluids. See Calibration Proce-  
Runaway  
1. If pump runaway occurs, the runaway solenoid will  
actuate, stopping the pump. The LED (AD) will flash  
and the display (AE) will indicate a runaway condi-  
tion. The display will cycle through four instruction  
screens.  
Setup Mode  
1. See Fig. 1. Press and hold  
Setup menu appears.  
for 5 seconds until  
2. To enter settings for flow rate units and displace-  
ment, press to change the value, then to  
save the value and move the cursor to the next data  
field.  
3. To enter setting for runaway (if equipped), enter  
pump speed in cycles/min. The exact setting will  
vary by pump speed and viscosity of fluid. Choose a  
setting that is just above the fastest speed expected  
during normal operation.  
2. To reset the runaway solenoid, close the master air  
valve. Wait for air to completely bleed off the air  
motor.  
3. Press  
to clear the diagnostic code and reset the  
NOTE: Set the value to zero to disable runaway protec-  
tion or if your pump is not equipped with a runaway pro-  
tection solenoid.  
runaway solenoid.  
4. Open master air valve to restart pump.  
NOTE: A flashing LED indicates an error that must be  
addressed. The Runaway mode will not stop a runaway  
pump while the LED is flashing.  
4. Move the cursor to the last field, then press  
once more to exit Setup mode.  
313840G  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
DataTrak Operation  
NOTE: If the DataTrak does not reset, use a screwdriver  
to push the solenoid release button on the side of the air  
valve.  
Counter/Totalizer  
To reset the totalizer, press any key to wake up the dis-  
play, then press and hold  
for 3 seconds.  
If AC is set to gallons or ounces, BT and GT dis-  
play gallons.  
If AC is set to liters or cc, BT and GT display  
liters.  
If AC is set to cycles, BT and GT display cycles.  
NOTE: Press  
to toggle between flow rate units and  
cycles. A letter under the BT display indicates that both  
BT and GT are displaying gallons (g) or liters (l). No let-  
ter means both BT and GT are displaying cycles.  
ti14263a  
5. If the solenoid doesn’t actuate:  
Display  
a. Close the master air valve to stop the pump.  
The display will show the Service Component 1  
See Fig. 1. The display (AE) will turn off after 1 minute of  
inactivity in Run mode or 3 minutes in Setup mode.  
Press any key to wake up the display.  
screen.  
NOTE: DataTrak will continue to count cycles when dis-  
play is off.  
NOTE: The display (AE) may turn off if a high-level static  
discharge is applied to the DataTrak. Press any key to  
wake up the display.  
b. See Table 1, Diagnostic Codes, on page 10.  
NOTE: To disable runaway monitoring, go to setup  
mode and set runaway value to 0 (zero). See Fig. 1.  
Diagnostics  
DataTrak can diagnose several problems with the pump.  
When the monitor detects a problem, the LED (AD, Fig.  
1) will flash and a diagnostic code will appear on the dis-  
play. See Table 1, page 10.  
Prime/Flush  
1. See Fig. 1. To enter Prime/Flush mode, press any  
key to wake up the display, then press  
Prime/Flush symbol will appear in the display and  
. The  
To acknowledge the diagnosis and return to the normal  
operating screen, press  
once to wake up the display,  
and once more to clear the diagnostic code screen.  
the LED will flash  
.
2. While in Prime/Flush mode, runaway protection is  
disabled and the batch totalizer (BT) will not count.  
3. To exit Prime/Flush mode, press any key to wake up  
the display, then press  
. The Prime/Flush sym-  
bol will disappear from the display and the LED will  
stop flashing.  
8
313840G  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DataTrak Operation  
Calibration Procedure  
1. Press and hold  
appears.  
for 5 seconds until Setup menu  
2. Press  
cycles/min.  
once. Change flow rate units to  
3. Return to Run Screen. Press and hold  
seconds to reset batch totalizer.  
for three  
4. Dispense fluid from pump into a graduated con-  
tainer.  
5. Convert the actual volume dispensed to cubic centi-  
meters (cc). See conversion chart.  
Units Measured Multiply by  
To get  
Gallons (U.S.)  
Gallons (Imp)  
Liters  
3785  
4546  
1000  
946  
29.57  
28.41  
16.39  
28,317  
473  
cc  
cc  
cc  
cc  
cc  
cc  
cc  
cc  
cc  
cc  
Quarts  
Ounces (U.S.)  
Ounces (Imp)  
Cubic inches  
Cubic feet  
Pints  
cc  
1
6. Divide the actual volume dispensed (cc) by the num-  
ber of cycles indicated on the DataTrak batch total-  
izer display.  
7. Press  
to enter the Setup screen. Enter the  
number from Step 6 in field 2 of the Setup screen.  
313840G  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
DataTrak Operation  
Table 1: Diagnostic Codes  
Symbol  
Code  
Code Name  
Diagnosis  
Cause  
Runaway  
Pump running faster than Increased air pressure.  
set runaway limit.  
Increased fluid output.  
Exhausted fluid supply.  
E-3 Low Battery  
E--4 Service  
Battery voltage too low to Low battery. Replace battery;  
stop runaway.  
see page 11.  
Problem with stopping  
Damaged solenoid.  
Component 1 runaway.  
Damaged valve carriage.  
Runaway protection may be  
enabled with pump that is not  
equipped with a runaway sole-  
noid valve. Enter setup screen  
and disable runaway protec-  
tion.  
E-4 Disconnected Solenoid is disconnected. Solenoid unplugged.  
Solenoid  
Damaged solenoid wires.  
E-6 Blown Fuse  
Fuse is blown. Replace  
fuse; see page 11.  
Faulty solenoid or solenoid  
wiring.  
Extreme temperatures (above  
140°F [60°C]).  
Runaway protection may be  
enabled with pump that is not  
equipped with a runaway sole-  
noid valve. Enter setup screen  
and disable runaway protec-  
tion.  
10  
313840G  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
DataTrak Operation  
Replace DataTrak Battery or Fuse  
3. Remove two screws on back of module to access  
battery.  
4. Disconnect the used battery and replace with an  
approved battery. See Fig. 4.  
To reduce the risk of fire and explosion, the battery  
and fuse must be replaced in a non-hazardous loca-  
tion.  
Table 2. Approved Batteries  
Use only an approved replacement battery, shown in  
Table 2, and an approved fuse, shown in Table 3. Use  
of an unapproved battery or fuse will void Graco’s war-  
ranty and Intertek and Ex approvals.  
Energizer alkaline # 522  
Varta alkaline # 4922  
Ultralife lithium # U9V  
Duracell alkaline # MN1604  
Replace Battery  
1. Unscrew cable from the reed switch assembly. See  
Fig. 2.  
ti14054a  
Fig. 2. Disconnect DataTrak  
2. Remove DataTrak module from bracket. See Fig. 3.  
Take module to a non-hazardous location.  
ti14053a  
Fig. 3. Remove DataTrak  
313840G  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
DataTrak Operation  
Replace Fuse  
Table 3. Approved Fuses  
DataTrak Part  
Fuse  
1. Remove the screw, metal strap, and plastic holder.  
Number  
Series*  
Required  
2. Pull the fuse away from the board.  
3. Replace with a new fuse.  
A or B  
C and later  
A
24C580  
24V216  
24C580  
24V216  
289822  
All other part  
numbers  
B and later  
* Fig. 4 shows where to find the Series letter.  
Solenoid Cable  
Connection  
Fuse  
SensorCable  
Connection  
Series Letter  
(last digit of code)  
ti11994b  
Battery  
Fig. 4. DataTrak Battery and Fuse Location  
12  
313840G  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
DataTrak Operation  
313840G  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Parts  
Parts  
Conversion Kits, Cycle Count and Runaway Protection  
Husky 1050 - 24B777 (Aluminum), 24B784 (Polypropylene), and 24B793 (Conductive Polypropylene)  
Husky 3300 - 24K861 (Aluminum) and 24K862 (Polypropylene)  
Aluminum  
6c  
6a  
1
2
3
6b  
ti14225a  
Plastic  
Plastic  
Aluminum  
6c  
6a  
4a  
4d  
4c  
4d  
4b  
6b  
4c  
ti14052a  
ti14226a  
14  
313840G  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Parts  
Ref.  
Ref.  
No. Part No. Description  
Qty  
No. Part No. Description  
Qty  
6
AIR VALVE, kit  
(includes Parts 6a-6c)  
1
1
-----  
DATATRAK module  
(see pages 11 and 12 for battery and  
fuse replacement information)  
1
24B767 Husky 1050 Aluminum  
2
3
4
-----  
-----  
CABLE  
BRACKET, wall  
1
1
1
24B774 Husky 1050 Polypropylene  
24B776 Husky 1050 Conductive  
Polypropylene  
SOLENOID/REED SWITCH, kit  
(includes Parts 4a-4d)  
24K856 Husky 3300 Aluminum  
24B771 Husky 1050 plastic air valve  
24B772 Husky 1050 aluminum air valve  
24K863 Husky 3300 plastic air valve  
24K864 Husky 3300 aluminum air valve  
24K858 Husky 3300 Polypropylene  
6a -----  
6b -----  
6c -----  
VALVE, air, smart  
GASKET, air valve  
FASTENERS, air valve  
1
1
4
M6 x 25 screw, Aluminum air valve  
M6 hex nut, Plastic air valve  
715V262 LABEL, warning (not shown)  
4a -----  
4b -----  
REED SWITCH with SOLENOID  
1
1
SCREW, reed switch  
8-32 x 1.50 taptite, aluminum air  
valve  
1
1
816A098 CARD, reference, language (not  
6-19 x 1-5/8 plastite, plastic air valve  
shown)  
4c -----  
4d -----  
BRACKET, solenoid  
FASTENER, solenoid  
M6 x 25 screw, aluminum air valve  
M6 hex nut, plastic air valve  
1
2
Replacement Warning labels, signs, tags, and cards  
are available at no cost.  
----- Not sold separately.  
313840G  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Parts  
Conversion Kits, Cycle Count Only  
Husky 1050 and Husky 3300 - 24B794 (Aluminum) and 24B795 (Polypropylene and Conductive  
Polypropylene)  
1
3
2
5a  
ti14224a  
5b  
Ref.  
No. Part No. Description  
Qty  
1
-----  
DATATRAK module  
1
(see pages 11 and 12 for battery  
and fuse replacement information)  
2
3
5
-----  
-----  
CABLE, CAN  
BRACKET, wall  
1
1
1
REED SWITCH, kit  
(includes Parts 5a-5b)  
24B796 Plastic air valve  
24B798 Aluminum air valve  
5a  
5b  
-----  
-----  
REED SWITCH  
1
1
SCREW, reed switch  
8-32 x 1.50 taptite, aluminum air  
valve  
6-19 x 1-5/8 plastite, plastic air  
valve  
6▲  
7▲  
15V262 LABEL, warning (not shown)  
1
1
16A098 CARD, reference, language (not  
shown)  
Replacement Warning labels, signs, tags, and cards  
are available at no cost.  
16  
313840G  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Parts  
Replacement Kits  
Solenoid/Reed Switch  
Husky Husky  
1050  
3300  
Air Valve Material  
Includes  
Plastic  
Reed switch and solenoid (4a),  
bracket (4c), and fasteners (4b, 4d)  
24B771 24K863  
24B772 24K864  
Aluminum  
Reed Switch  
Husky  
1050 or  
Husky  
3300  
Air Valve Material  
Includes  
Plastic  
24B796  
24B798  
Reed switch (5a)  
and fastener (5b)  
Aluminum  
313840G  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Graco Standard Warranty  
Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in  
material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty  
published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by  
Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written  
recommendations.  
This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty  
installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of  
non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with  
structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or  
maintenance of structures, accessories, equipment or materials not supplied by Graco.  
This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of  
the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned  
to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will  
be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.  
THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED  
TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.  
Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy  
(including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or  
consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.  
GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A  
PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT  
MANUFACTURED BY GRACO. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to  
the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these  
warranties.  
In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or  
the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the  
negligence of Graco, or otherwise.  
FOR GRACO CANADA CUSTOMERS  
The Parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into,  
given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la  
rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés, à la suite  
de ou en rapport, directement ou indirectement, avec les procédures concernées.  
Graco Information  
For the latest information about Graco products, visit www.graco.com.  
For patent information, see www.graco.com/patents.  
TO PLACE AN ORDER, contact your Graco distributor or call to identify the nearest distributor.  
Phone: 612-623-6921 or Toll Free: 1-800-328-0211 Fax: 612-378-3505  
All written and visual data contained in this document reflects the latest product information available at the time of publication.  
Graco reserves the right to make changes at any time without notice.  
Original instructions.This manual contains English. MM 313840  
Graco Headquarters: Minneapolis  
International Offices: Belgium, China, Japan, Korea  
GRACO INC. AND SUBSIDIARIES • P.O. BOX 1441 • MINNEAPOLIS MN 55440-1441 • USA  
Copyright 2009, Graco Inc. All Graco manufacturing locations are registered to ISO 9001.  
Revision G, July 2014  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   

Haier Refrigerator BC100GS User Manual
Hamilton Beach Air Cleaner 04255 User Manual
Harbor Freight Tools Grinder 52847 User Manual
Harbor Freight Tools Outdoor Cart 40129 User Manual
Harman Kardon DVD Player DVD22B User Manual
Hayter Mowers Lawn Mower Code 100C User Manual
Hearth and Home Technologies Indoor Fireplace ST TRC User Manual
Hotpoint Ice Maker ffaa52k 1 User Manual
IBM Network Card EtherLink XL User Manual
Impex Home Gym MWB 345 User Manual