Instructions – Parts List
Parts
2:1 Ratio MonarkR Pump
200 psi (1.4 MPa, 14 bar) Maximum Fluid Working Pressure
100 psi (0.7 MPa, 7 bar) Maximum Air Input Pressure
307985J
Part No. 223185, Series C
55 Gallon (200 Liter) Drum Size, UHMWPE and Leather Packed
0359
II 1/2 G T6
ITS03ATEX11228
Part No. 223186, Series C
Stubby Size, UHMWPE and Leather Packed
0359
T6
Important Safety Instructions
Read all warnings and instructions in this manual.
Save these instructions.
Table of Contents
Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Mounting Hole Layout . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Graco Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Graco Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
06085
Model 223186 Shown
GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440–1441
Copyright 1989, Graco Inc. is registered to I.S. EN ISO 9001
Download from Www.Somanuals.com. All Manuals Search And Download.
WARNING
FIRE AND EXPLOSION HAZARD
Improper grounding, poor ventilation, open flames or sparks can cause a hazardous condition and
result in a fire or explosion and serious injury.
D Ground the equipment and the object being sprayed. Refer to Grounding on page 5.
D If there is any static sparking or you feel an electric shock while using this equipment, stop spray-
ing immediately. Do not use the equipment until you identify and correct the problem.
D Provide fresh air ventilation to avoid the buildup of flammable fumes from solvents or the fluid
being sprayed.
D Keep the spray area free of debris, including solvent, rags, and gasoline.
D Electrically disconnect all equipment in the spray area.
D Extinguish all open flames or pilot lights in the spray area.
D Do not smoke in the spray area.
D Do not turn on or off any light switch in the spray area while operating or if fumes are present.
D Do not operate a gasoline engine in the spray area.
TOXIC FLUID HAZARD
Hazardous fluid or toxic fumes can cause serious injury or death if splashed in the eyes or on the skin,
inhaled, or swallowed.
D Know the specific hazards of the fluid you are using.
D Store hazardous fluid in an approved container. Dispose of hazardous fluid according to all local,
state and national guidelines.
D Always wear protective eyewear, gloves, clothing and respirator as recommended by the fluid and
solvent manufacturer.
MOVING PARTS HAZARD
Moving parts, such as the air motor piston, can pinch or amputate your fingers.
D Keep clear of all moving parts when starting or operating the pump.
D Before servicing the equipment, follow the Pressure Relief Procedure on page 8 to prevent the
equipment from starting unexpectedly.
307985
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Notes
4
307985
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
Z
General Information
X
W
NOTE: Reference numbers and letters in parentheses
in the text refer to the callouts in the figures and the
parts drawing.
NOTE: Always use Genuine Graco Parts and Acces-
sories, available from your Graco distributor. If you
supply your own accessories, be sure they are ade-
quately sized and pressure rated for your system.
Y
0864
Fig. 1
2. Air and fluid hoses: use only electrically conductive
Fig. 2 is only a guide for selecting and installing sys-
tem components and accessories. Contact your Graco
distributor for assistance in designing a system to suit
your particular needs.
hoses.
3. Air compressor: follow manufacturer’s recommen-
dations.
4. Spray gun: ground through connection to a proper-
ly grounded fluid hose and pump.
Prepare the Operator
5. Fluid supply container: follow your local code.
6. Object being sprayed: follow your local code.
All persons who operate the equipment must be
trained in the safe, efficient operation of all system
components as well as the proper handling of all fluids.
All operators must thoroughly read all instruction
manuals, tags, and labels before operating the equip-
ment.
7. Solvent pails used when flushing: follow your local
code. Use only metal pails, which are conductive,
placed on a grounded surface. Do not place the
pail on a nonconductive surface, such as paper or
cardboard, which interrupts the grounding continu-
ity.
Grounding
8. To maintain grounding continuity when flushing or
relieving pressure, hold a metal part of the spray
gun firmly to the side of a grounded metal pail,
then trigger the gun.
WARNING
FIRE AND EXPLOSION HAZARD
Before operating the pump, ground the
system as explained below. Also read
the section FIRE AND EXPLOSION
HAZARD on page 3.
Mounting the Pump
Mount the pump to suit the type of installation planned.
The pump dimensions and mounting hole layout are
shown on page 16.
If the pump is immersed, be sure the pump intake is
1/2 in. (13 mm) off the bottom of the fluid container.
1. Pump: order Part No. 237569 Ground Wire and
Clamp. See Fig. 1. Loosen the grounding lug
locknut (W) and washer (X). Insert one end of the
ground wire (Y) into the slot in lug (Z) and tighten
the locknut securely. Connect the other end of the
wire to a true earth ground.
If the pump is mounted on the wall or on a stand,
connect a suction line to the pump’s 1–1/2 in. npt(f)
fluid inlet and place the other end of the line in the fluid
container.
307985
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
KEY
A
Bleed-Type Master Air Valve
F
G
H
J
K
L
Fluid Shutoff Valves
Fluid Filter
Fluid Pressure Regulator
Air Spray Gun
Back Pressure Regulator
Pump
M
N
Air Supply Line
Bleed-Type Master Air Valves
(for accessories)
Main Fluid Supply Line
Pump Runaway Valve
S
T
Y
Main Fluid Return Line
Secondary Fluid Return Line
Ground Wire (required;
see page 5 for installation
instructions)
(required, for pump)
Air Filter/Regulator
Air Line Lubricator
Fluid Drain Valve (required)
Surge Tank
B
C
D
E
P
R
B
N
H
F
M
N
M
B
P
J
Y
F
G
F
E
R
L
M
F
K
F
K
F
T
D
A
C
S
06089
Fig. 2
6
307985
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
Fluid Line Accessories
Available Accessories (must be
purchased separately)
WARNING
Air Line Accessories
A fluid drain valve (D) is required in your system to
help reduce the risk of serious injury, including
splashing of fluid in the eyes or on the skin.
WARNING
A bleed-type master air valve (A) is required in your
system to help reduce the risk of serious injury,
including splashing of fluid in the eyes or on the
skin, and injury from moving parts if you are adjust-
ing or repairing the pump.
The fluid drain valve assists in relieving fluid pres-
sure in the displacement pump, hose, and gun.
Triggering the gun to relieve pressure may not be
sufficient.
The bleed-type master air valve relieves air trapped
between this valve and the pump after the air is
shut off. Trapped air can cause the pump to cycle
unexpectedly. Locate the valve close to the pump.
D The fluid drain valve (D) is required in your sys-
tem to relieve fluid pressure in the hose and gun
(see the WARNING above).
D Install a surge tank (E) to reduce fluid line pulsa-
D The bleed-type master air valve (A) is required in
your system to relieve air trapped between it and
the air motor when the valve is closed (see the
WARNING above). Be sure the bleed valve is
easily accessible from the pump, and is located
downstream from the air filter/regulator (B). Order
Part No. 113269 Bleed Valve.
tions.
D Install two fluid filters (G) to remove impurities
from the fluid before it reaches the spray gun (J).
Install fluid shutoff valves (F) upstream and down-
stream from each filter; this arrangement enables
you to continue spraying while cleaning a filter.
D The air filter/regulator (B) controls pump speed
and outlet pressure by adjusting the air pressure to
the pump and the air spray gun. It also removes
harmful dirt and moisture from the compressed air
supply. Locate the pump air filter/regulator up-
stream from the pump’s bleed-type master air
valve (A). Also, supply an air filter/regulator at each
spray booth.
D Install a fluid pressure regulator (H) to provide
precise fluid pressure control at each spray booth.
D Install fluid shutoff valves (F) where shown.
Fluid Return Line
D Install a main fluid return line (S) to circulate fluid
back to the pump’s return port.
D A pump runaway valve (R) automatically shuts off
the pump if it starts running too fast. A pump which
runs too fast can be seriously damaged.
D Install a secondary fluid return line (T) to circu-
late fluid from the spray guns back to the fluid
supply container.
D An air line lubricator (C) provides automatic air
motor lubrication. Install downstream from the
pump air filter/regulator (B).
D Install a back pressure regulator (K) on each
fluid return line, after the last gun station, to provide
constant system back pressure for all spray guns
and proper pressure for fluid circulation.
D Install additional air bleed valves (N) at each air
line drop, to isolate accessories for servicing.
307985
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation
If the pump is not immersed, fill the packing nut/wet-
Pressure Relief Procedure
cup 1/2 full with a compatible solvent. Keep the cup
filled at all times to help prevent the fluid you are
pumping from drying on the exposed displacement rod
and damaging the throat packings.
WARNING
PRESSURIZED EQUIPMENT HAZARD
The system pressure must be manually relieved to
prevent the system from starting or spraying acci-
dentally. To reduce the risk of an injury from acci-
dental spray from the gun, splashing fluid, or
moving parts, follow the Pressure Relief Proce-
dure whenever you:
Flush the Pump Before First Use
The pump is tested with lightweight oil, which is left in
to protect the pump parts. If the fluid you are using
may be contaminated by the oil, flush it out with a
compatible solvent. See Flushing on page 11.
D are instructed to relieve the pressure,
D stop spraying,
D check or service any of the system equipment,
D or install or clean the spray nozzle.
Model 223186 Shown
1. Shut off the air supply to the pump.
2. Close the bleed-type master air valve (A, required
in your system).
3. Hold a metal part of the gun firmly to the side of a
grounded metal pail, and trigger the gun to relieve
pressure.
4. Open the drain valve (D, required in your system),
having a container ready to catch the drainage.
5. Leave the drain valve open until you are ready to
spray again.
If you suspect that the spray nozzle or hose is com-
pletely clogged, or that pressure has not been fully
relieved after following the steps above, very slowly
loosen the nozzle retaining ring or hose end coupling
and relieve pressure gradually, then loosen completely.
Now clear the nozzle or hose.
U
Packing Nut
WARNING
To reduce the risk of serious injury whenever you
are instructed to relieve pressure, always follow the
Pressure Relief Procedure above.
Check the tightness of the packing nut/wet-cup (U)
periodically. The nut should be tight enough to prevent
leakage. Torque the nut to 20–24 ft-lb (27–33 N.m); do
not overtighten or you may damage the packings.
Relieve pressure before adjusting the nut. See Fig. 3.
06085
Fig. 3
8
307985
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation
Prime the Pump
WARNING
To reduce the risk of serious injury whenever you
are instructed to relieve pressure, always follow the
Pressure Relief Procedure on page 8.
1. See Fig. 2. Remove the spray nozzle from the
gun. See the gun instruction manual.
2. Close all bleed-type air valves (A, N).
3. Close the pump air filter/regulator (B).
4. Close the fluid drain valve (D).
11. Relieve the pressure. Install the spray nozzle in
the gun, as explained in the gun manual.
5. Check that all fittings throughout the system are
tightened securely.
WARNING
COMPONENT RUPTURE HAZARD
To reduce the risk of overpressurizing
your system, which could cause compo-
nent rupture and serious injury, never
exceed 100 psi (7 bar) air supply pressure to the
pump.
6. Connect the air supply line to the pump air inlet.
7. Open the bleed-type air valves (A, N).
8. Hold a metal part of the gun firmly to the side of a
grounded metal pail and hold the trigger open.
12. Use the air filter/regulator (B) to control pump
outlet pressure and pump speed. Always use the
lowest pressure necessary to get the desired
results. Higher pressure causes premature pump
wear.
9. Open the air filter/regulator (B) until the pump
starts. Run the pump slowly until all air is pushed
out and the system is fully primed. Always use the
lowest pressure necessary to get the desired
results. Higher pressures cause premature tip and
pump wear.
CAUTION
10. Release the gun trigger and lock the trigger safety.
Do not allow the pump to run dry. It will quickly
accelerate to a high speed, causing damage. If your
pump is running too fast, stop it immediately and
check the fluid supply. If the container is empty and
air has been pumped into the lines, refill the con-
tainer and prime the pump and the lines, or flush and
leave it filled with a compatible solvent. Eliminate all
air from the fluid system.
In a circulating system, the pump will run continu-
ously and slow down or speed up on demand, until
the air supply is shut off.
In a direct supply system, with adequate air pres-
sure supplied to the motor, the pump will start and
stop as you open and close the gun.
307985
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Notes
10
307985
Download from Www.Somanuals.com. All Manuals Search And Download.
Maintenance
Shutdown and Care of the Pump
CAUTION
Never leave water or water-base fluid in the pump
overnight. If you are pumping water-base fluid, flush
with water first, then with a rust inhibitor such as
mineral spirits. Relieve the pressure, but leave the
rust inhibitor in the pump to protect the parts from
corrosion.
WARNING
To reduce the risk of serious injury whenever you
are instructed to relieve pressure, always follow the
Pressure Relief Procedure on page 8.
For overnight shutdown, stop the pump at the bottom
of its stroke to prevent fluid from drying on the ex-
posed displacement rod and damaging the throat
packings. Relieve the pressure.
WARNING
To reduce the risk of serious injury whenever you
are instructed to relieve pressure, always follow the
Pressure Relief Procedure on page 8.
Always flush the pump before the fluid dries on the
displacement rod. See Flushing below.
1. Relieve the pressure.
2. Remove the spray nozzle from the gun.
Flushing
3. Hold a metal part of the gun firmly to the side of a
grounded metal pail.
WARNING
4. Start the pump. Always use the lowest possible
fluid pressure when flushing.
FIRE AND EXPLOSION HAZARD
Before flushing, read the section FIRE
AND EXPLOSION HAZARD on page
3. Be sure the entire system and flush-
ing pails are properly grounded. Refer to
Grounding on page 5.
5. Trigger the gun.
6. Flush the system until clear solvent flows from the
gun.
7. Relieve the pressure.
Flush the pump:
8. Clean the spray nozzle separately, then reinstall it.
Corrosion Protection for Carbon Steel
Pumps
D Before the first use
D When changing colors or fluids
CAUTION
Water, or even moist air, can cause your pump to
corrode. To help prevent corrosion, never leave the
pump filled with water or air. Follow the instructions
under Flushing, at left.
D Before fluid can dry or settle out in a dormant pump
(check the pot life of catalyzed fluids)
D Before storing the pump.
Fluid Piston and Intake Valve Adjustment
Flush with a fluid that is compatible with the fluid you
are pumping and with the wetted parts in your system.
Check with your fluid manufacturer or supplier for
recommended flushing fluids and flushing frequency.
The fluid piston and intake valves are factory set for
pumping medium viscosity fluids. See the separate
displacement pump manual, 307983, for adjustment
procedures to pump lighter or heavier viscosity fluids.
307985 11
Download from Www.Somanuals.com. All Manuals Search And Download.
Troubleshooting
1. Relieve the pressure.
WARNING
To reduce the risk of serious injury whenever you
are instructed to relieve pressure, always follow the
Pressure Relief Procedure on page 8.
2. Check all possible problems and solutions before
disassembling pump.
Problem
Cause
Restricted line or inadequate air
Solution
Pump fails to operate.
Clear; increase air supply.
supply.
Dirty or damaged air motor.
Clogged fluid hose, gun, or nozzle.
Service air motor (see 307043).
Clear.*
Pump operates but output is low on Restricted line or inadequate air
Clear; increase air supply.
both strokes.
supply.
Exhausted fluid supply.
Clogged fluid hose, gun, or nozzle.
Refill; reprime or flush.
Clear.*
Loose packing nut or worn throat
packings.
Tighten packing nut (see page 8);
replace throat packings.
Piston and intake valves need ad-
justment.
Adjust; see manual 307983.
Pump operates but output is low on Held open or worn intake valve.
downstroke.
Clear; service. See manual 307983.
Pump operates but output is low on Held open or worn fluid piston valve Clear; service. See manual 307983.
upstroke.
or packings.
Erratic or accelerated operation.
Exhausted fluid supply.
Refill; reprime or flush.
Piston and intake valves need ad-
justment.
Adjust; see manual 307983.
Held open or worn intake valve.
Clear; service. See manual 307983.
Held open or worn fluid piston valve Clear; service. See manual 307983.
or packings.
* To determine if the fluid hose or gun is obstructed, follow the Pressure Relief Procedure on page 8. Discon-
nect the fluid hose and place a container at the pump fluid outlet to catch any fluid. Turn on the air just enough to
start the pump (about 20–40 psi [1.4–2.8 bar]). If the pump starts when the air is turned on, the obstruction is in
the fluid hose or gun.
12
307985
Download from Www.Somanuals.com. All Manuals Search And Download.
Service
6. Turn on the air to the motor and run the pump
Disconnecting the Displacement Pump
slowly. Adjust the locknuts (9) on the return mount-
ing tube (11) as necessary until the pump operates
smoothly at minimum air pressure to the motor.
Tighten the locknuts securely.
NOTE: For displacement pump repair instructions,
refer to the separate displacement pump manual
307983, supplied.
7. Reconnect the ground wire if it was disconnected
during repair.
WARNING
To reduce the risk of serious injury whenever you
are instructed to relieve pressure, always follow the
Pressure Relief Procedure on page 8.
8. If the pump is not immersed, fill the packing nut/
wet-cup 1/2 full of compatible solvent.
1. Flush the pump if possible. Stop the pump at the
Torque to 65–75 ft-lb (88–102 N.m).
Use thread sealant when reinstalling.
1
2
bottom of its stroke. Relieve the pressure.
2. Disconnect all hoses and remove the pump from
its mounting.
3
Lubricate.
3. Unscrew the coupling nut (14) from the displace-
ment rod (R). Remove the coupling collars (15).
See Fig. 4.
Model 223186
Shown
1
4. Unscrew the lower locknut (9) and lockwasher (7)
from the return mounting tube (11).
5. Unscrew the swivel union (S) from the supply
mounting tube (12).
2
14
8
CAUTION
If you are removing the mounting tubes, wrench the
tubes close to the motor base to prevent thread
damage in the base. Use thread sealant on the male
threads when reinstalling.
11
3
6
4
1
2
Reconnecting the Displacement Pump
12
15
9
7
1. Position the displacement pump on the mounting
tubes (11, 12). Thread the upper locknut (9) onto
the return mounting tube (11) a couple of turns.
Tighten the swivel union (S) securely onto the
supply mounting tube (12). See Fig. 4.
R
S
2. Butt the connecting rod (4) and displacement rod
(R) together; if necessary, adjust the locknuts (9)
on the return mounting tube (11) to align the rods.
3
7
9
3. Position the coupling collars (15) so they engage
with the connecting rod (4) and displacement rod
(R). Lower the coupling nut (14) over the coupling
collars and screw it securely onto the displacement
rod.
4. Tighten the locknuts (9) securely.
06086
Fig. 4
5. Remount the pump and connect all hoses.
307985 13
Download from Www.Somanuals.com. All Manuals Search And Download.
Parts
Model 223185, Series C
2:1 Ratio Monark Pump, 55 Gallon (200 Liter) Drum Size; UHMWPE and Leather Packed
Ref
No.
Part
No.
1
Used on Model 223185 only.
Description
Qty
1
3
206955
223177
AIR MOTOR, Monark
See 307043 for parts
PUMP, displacement;
used on Model 223185
See 307983 for parts
ROD, connecting;
1
1
1
4
191611
19.54 in. (496.3 mm) long
PIN, cotter
LOCKWASHER, ext shakeproof
O-RING; nitrile rubber
NUT, special lock;
1
1
2
1
6
7
8
9
100579
162648
156082
160026
13
1
3/4 garden hose thread
TUBE, return;
24.675 in. (626.7 mm) long
2
1
1
11
12
13
162646
190177
160032
14
8
TUBE, supply;
19.3 in. (490.2 mm) long
NIPPLE; 3/4 npt (used on
Model 223185 only)
NUT, coupling
11
1
1
2
6
4
14
15
190117
190066
COLLAR, coupling
12
15
9
7
3
7
9
06087
14
307985
Download from Www.Somanuals.com. All Manuals Search And Download.
Parts
Model 223186, Series C
2:1 Ratio Monark Pump, Stubby Size; UHMWPE and Leather Packed
Ref
No.
Part
No.
Description
Qty
1
3
206955
223177
AIR MOTOR, Monark
See 307043 for parts
PUMP, displacement;
used on Model 223186
See 307983 for parts
ROD, connecting;
1
1
1
4
191736
6.98 in. (177.3 mm) long
PIN, cotter
LOCKWASHER, ext shakeproof
O-RING; nitrile rubber
NUT, special lock;
1
1
2
1
6
7
8
9
100579
162648
156082
160026
14
8
3/4 garden hose thread
TUBE, return;
12.812 in. (325.4 mm) long
2
1
11
12
181120
190178
11
TUBE, supply;
6.75 in. (171.5 mm) long
NUT, coupling
COLLAR, coupling
1
1
2
6
4
14
15
190117
190066
12
15
9
7
3
7
9
06086
307985 15
Download from Www.Somanuals.com. All Manuals Search And Download.
Dimensions
Mounting Hole
Layout
0.375 in.
(9.52 mm)
diameter
2.254 in.
(57.25 mm)
B
2.254 in.
(57.25 mm)
3.188 in.
(80.97 mm)
A
2.625 in.
(66.67 mm)
5.250 in.
(133.4 mm)
C
3/4 npt(f)
return
1 in. npt(f)
outlet
NOTE: Use mounting gasket 161322.
06088
06085
Model No.
A
B
C
223185
47.81 in.
(1215 mm)
15.31 in.
(389 mm)
32.5 in.
(826 mm)
223186
35.31 in.
(897 mm)
15.31 in.
(389 mm)
20 in.
(508 mm)
16
307985
Download from Www.Somanuals.com. All Manuals Search And Download.
Technical Data
Category
Data
Ratio
2:1
Maximum fluid working pressure
Maximum air input pressure
Pump cycles per 1 gallon (3.8 liters)
Fluid flow at 60 cycles per minute
Fluid inlet size
200 psi (14 bar)
100 psi (7 bar)
11
5.5 gpm (21 liters/min)
1–1/2 npt(f)
1 in. npt(f)
Fluid outlet size
Air inlet size
3/8 npsm(f)
40 lb (18.14 kg)
180_F (82_C)
Weight
Maximum pump operating temperature
* Sound level at 100 psi, 15 cycles per minute
* Sound power level at 100 psi, 15 cycles per minute
Wetted parts
62.6 dBa
71.8 dBa
Supply and Return Tubes: Nickel-plated carbon steel
Air Motor Base: Aluminum
Displacement Pump: Refer to manual 307983
* Tested in accordance with ISO 3744.
KEY: Fluid Outlet Pressure - Black Curves
A
B
C
100 psi (7 bar) air pressure
70 psi (4.9 bar) air pressure
40 psi (2.8 bar) air pressure
Air Consumption - Gray Curves
cycles per min
240
16
32
48
64
psi
12.0 scfm
bar 16.8
0.336 m#/min
200
14.0
10.0
0.280
A
B
A
160
11.2
8.0
0.224
120
8.4
6.0
0.168
B
C
C
80
5.6
4.0
0.112
40
2.8
2.0
0.056
0
0.0
1.5
3.0
4.5
6.0
23
gpm
liters/min
5.7
11.4
17
FLUID FLOW (TEST FLUID: NO 10 MOTOR OIL)
To find Fluid Outlet Pressure (bar/psi) at a specific fluid flow (lpm/
gpm) and operating air pressure (bar/psi):
To find Pump Air Consumption (m#/min or scfm) at a specific fluid
flow (lpm/gpm) and operating air pressure (bar/psi):
1. Locate desired flow along bottom of chart.
1. Locate desired flow along bottom of chart.
2. Follow vertical line up to intersection with selected fluid outlet
pressure curve (black). Follow left to scale and read fluid outlet
pressure.
2. Follow vertical line up to intersection with selected air consump-
tion curve (gray). Follow right to scale and read air consumption.
307985 17
Download from Www.Somanuals.com. All Manuals Search And Download.
Graco Standard Warranty
Graco warrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on the
date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco,
Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be
defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written
recommendations.
This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by
faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or sub-
stitution of non–Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of
Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture,
installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco.
This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for
verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The
equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect
in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and
transportation.
THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT
NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.
Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other
remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any
other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the
date of sale.
Graco makes no warranty, and disclaims all implied warranties of merchantability and fitness for a particular purpose in connection
with accessories, equipment, materials or components sold but not manufactured by Graco. These items sold, but not manufactured
by Graco (such as electric motors, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide
purchaser with reasonable assistance in making any claim for breach of these warranties.
In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment
hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract,
breach of warranty, the negligence of Graco, or otherwise.
FOR GRACO CANADA CUSTOMERS
The parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings
entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnais-
sent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires
exécutés, donnés ou intentés à la suite de ou en rapport, directement ou indirectement, avec les procedures concernées.
Graco Information
TO PLACE AN ORDER, contact your Graco distributor, or call one of the following numbers
to identify the distributor closest to you:
1–800–328–0211 Toll Free
612–623–6921
612–378–3505 Fax
All written and visual data contained in this document reflects the latest product information available at the time of publication.
Graco reserves the right to make changes at any time without notice.
MM 307985
Graco Headquarters: Minneapolis
International Offices: Belgium, China, Japan, Korea
307985 10/1989, Revised 06/2006
18
307985
Download from Www.Somanuals.com. All Manuals Search And Download.
|