Graco Marine Safety Devices 122193 User Manual

Instructions-Parts  
313542D  
ENG  
Beacon Tower  
®
Diagnostic indicator for use with ProMix 2KS and ProMix 2KE Proportioner.  
For professional use only.  
Not for use in explosive atmospheres.  
Important Safety Instructions  
Read all warnings and instructions in your propor-  
tioner installation, operation, and repair manuals.  
Save these instructions.  
Part No. 122193 Beacon Tower  
Includes beacon tower only.  
Part No. 15W034 Beacon Tower Kit  
Includes beacon tower, cable, connectors, and mounting hardware.  
122193 Beacon  
Tower Shown  
TI14039a  
Download from Www.Somanuals.com. All Manuals Search And Download.  
122193 Beacon Tower Installation  
122193 Beacon Tower Installation  
Install on a ProMix 2KS  
Install on a ProMix 2KE  
NOTE: Beacon Tower 122193 is for ProMix 2KS auto-  
matic systems (ADxxxx or RDxxxx), or manual systems  
with wire harness 15W023 installed.  
1. Disconnect the existing alarm from pins 1 and 2 on  
the terminal strip. See FIG. 3.  
2. Mount the beacon near the control box and secure  
with jam nuts. Feed the wires into the box.  
1. Remove the 3/4 in. (19 mm) knockout on top of the  
EasyKey. Feed the wires through the hole and  
secure the beacon (1) with jam nuts (N) on the  
inside and outside of the box. See FIG. 1.  
3. Connect the yellow wire from the beacon to pin 12  
on the terminal strip.  
4. Connect the gray wire from the beacon to pin 2 on  
the terminal strip.  
2. Connect yellow and gray wires from beacon to the  
power terminal. See FIG. 2.  
5. Connect either the orange, brown, or red wire to pin  
1 on the terminal strip.  
3. Connect orange, brown, and red wires to header  
pins 6, 7, and 8. See FIG. 5 on page 6.  
6. To enable the optional audible alarm, connect sky  
blue wire to pin 1 on the terminal strip. When  
enabled, it will sound for all system alarms.  
4. To enable the optional audible alarm, connect sky  
blue wire to pin 6 on header. See FIG. 5 on page 6.  
When enabled, it will sound for all system alarms.  
7. When beacon wiring is completed, insulate the end  
of each unused lead wire with insulation tape.  
5. When beacon wiring is completed, insulate the end  
of each unused lead wire with insulation tape.  
Beacon Wires Schematic  
1 2  
12 14  
SKY BLUE  
ti15730a  
NOTE: Sky Blue wire is for  
optional audible alarm.  
FIG. 3. Beacon Connections in Control Box, ProMix 2KE  
313542D  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
122193 Beacon Tower Installation  
4
313542D  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Parts  
Parts  
122193 Beacon Tower, includes item 1 only  
15W034 Beacon Tower Kit, includes items 1-8  
Ref Description  
Qty  
1
1
2
3
4
LIGHT TOWER, Part No. 122193  
3
1
1
CONNECTOR, terminal, female  
CONNECTOR, 10 position  
WIRE HARNESS, 3 conductor with shield;  
24 in. (0.6 m)  
1
1
1
2
5
6
7
8
HEADER, 5 position, din rail mount  
CONNECTOR, 5 position  
DIN RAIL  
SCREW, machine; 6-32 x 1/4 in. (6 mm)  
1
Mount din rail (7) in these holes,  
using two screws (8).  
TI12578a  
2, 3  
6
Last Pin  
TI14039a  
5
TI14038a  
Pin 1  
Pin 2  
4
FIG. 4: 15W034 Beacon Kit Parts  
313542D  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Wiring Diagrams  
122193 Beacon Tower (for ProMix 2KS Automatic Systems)  
Communications and I/O Harness 15W023 is included with Automatic Systems.  
Connection points inside the dashed line are already made in the EasyKey.  
POWER DISTRIBUTION  
TERMINALS  
1
-
+
Wire Harness 15W023  
DISPLAY BOARD  
1
2
FLOW CONTROL CAL. (BLK)  
GUN TRIGGER (WHT)  
1
2
3
DIGITAL IN COMMON (RED)  
REMOTE STOP (GRN)  
3
4
(+24)YELLOW  
(COM)GRAY  
ORANGE  
BROWN  
4
ALARM  
5
ALARM RESET (BRN)  
5
J5  
6
ALARM OUTPUT (BLU)  
6
7
DIGITAL OUTPUT COMMON (ORG)  
POT LIFE (YEL)  
7
RED  
8
8
SKY BLUE  
FLOW RATE ANALOG IN (PUR)  
FLOW RATE ANALOG COMMON (GRAY)  
9
9
10  
10  
NOTE: Sky Blue wire is for  
optional audible alarm.  
FIG. 5: 122193 Beacon Tower Wiring Diagram  
15W034 Beacon Tower Kit (for ProMix 2KS Manual Systems)  
NOTE: Item 4 Wire Harness is included with Kit 15W034.  
POWER DISTRIBUTION  
TERMINALS  
- +  
6
5
1
4
DISPLAY BOARD  
NOT USED  
NOT USED  
2
NOT USED  
3
NOT USED  
(+24) YELLOW  
(COM) GRAY  
ORANGE  
BROWN  
4
1
2
3
4
5
ALARM  
NOT USED  
5
J5  
ALARM OUTPUT (BLK)  
DIGITAL OUTPUT COMMON (WHT)  
POT LIFE (RED)  
NOT USED  
6
7
RED  
8
SKY BLUE  
9
NOT USED  
10  
GND  
LUG  
NOTE: Sky Blue wire is for  
optional audible alarm.  
FIG. 6: 15W034 Beacon Tower Kit Wiring Diagram  
Graco Information  
TO PLACE AN ORDER, contact your Graco distributor or call to identify the nearest distributor.  
Phone: 612-623-6921 or Toll Free: 1-800-328-0211 Fax: 612-378-3505  
All written and visual data contained in this document reflects the latest product information available at the time of publication.  
Graco reserves the right to make changes at any time without notice.  
Original instructions. This manual contains English. MM 313542  
Graco Headquarters: Minneapolis  
International Offices: Belgium, China, Japan, Korea  
GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440-1441  
Copyright 2009, Graco Inc. is registered to ISO 9001  
Revised 11/2010  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 

Graco Stroller ISPA204AA User Manual
Grindmaster Beverage Dispenser PIC 4 User Manual
Hasbro Motorized Toy Car 33392 User Manual
Heatiator Indoor Fireplace BF36A User Manual
HP Hewlett Packard Photo Printer Z3100 series User Manual
HP Hewlett Packard Photo Scanner J310 User Manual
Huey Chiao Headphones HCB12 User Manual
Hyundai Car Stereo System H CDM8053 User Manual
Hyundai Flat Panel Television HQL170WR User Manual
i Tech Dynamic Headphones Bluetooth Stereo Headphone User Manual