Graco Inc Paint Sprayer 1095 Premium Hi User Manual

Operation  
3A0156A  
Electric Airless Sprayers  
ENG  
- For Portable Airless Spraying of Architectural Coatings and Paints -  
3300 psi (227 bar, 22.7 MPa) Maximum Working Pressure  
IMPORTANT SAFETY INSTRUCTIONS  
Read all warnings and instructions in this  
manual. Save these instructions.  
ti15034a  
ti14838a  
695/795  
695/795 Premium Hi  
ti15036a  
ti15035a  
Related Manuals:  
Repair  
Parts  
Gun  
3A0157  
3A0158  
311861  
MARK V  
1095/1595 Premium Hi  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Warnings  
Warnings  
The following warnings are for the setup, use, grounding, maintenance and repair of this equipment. The exclamation  
point symbol alerts you to a general warning and the hazard symbol refers to procedure-specific risks. Refer back  
to these warnings. Additional, product-specific warnings may be found throughout the body of this manual where appli-  
cable.  
Grounding Instructions  
This product must be grounded. In the event of an electrical short circuit, grounding reduces the risk of electric shock by  
providing an escape wire for the electric current. This product is equipped with a cord having a grounding wire with an  
appropriate grounding plug. The plug must be plugged into an outlet that is properly installed and grounded in accor-  
dance with all local codes and ordinances.  
WARNING  
GROUNDING  
This product must be grounded. In the event of an electrical short circuit, grounding reduces the risk of elec-  
tric shock by providing an escape wire for the electric current. This product is equipped with a cord having a  
grounding wire with an appropriate grounding plug. The plug must be plugged into an outlet that is properly  
installed and grounded in accordance with all local codes and ordinances.  
Improper installation of the grounding plug is able to result in a risk of electric shock.  
When repair or replacement of the cord or plug is required, do not connect the grounding wire to either  
flat blade terminal.  
The wire with insulation having an outer surface that is green with or without yellow stripes is the ground-  
ing wire.  
Check with a qualified electrician or serviceman when the grounding instructions are not completely  
understood, or when in doubt as to whether the product is properly grounded.  
Do not modify the plug provided; if it does not fit the outlet, have the proper outlet installed by a qualified  
electrician.  
This product is for use on a nominal 120V circuit and has a grounding plug similar to the plug illustrated  
in the figure below.  
Only connect the product to an outlet having the same configuration as the plug.  
Do not use an adapter with this product.  
Extension Cords:  
Use only a 3-wire extension cord that has a 3-blade grounding plug and a 3-slot receptacle that accepts  
the plug on the product.  
Make sure your extension cord is not damaged. If an extension cord is necessary, use 12 AWG  
(2.5 mm2) minimum to carry the current that the product draws.  
An undersized cord results in a drop in line voltage and loss of power and overheating.  
3A0156A  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Warnings  
WARNING  
FIRE AND EXPLOSION HAZARD  
Flammable fumes, such as solvent and paint fumes, in work area can ignite or explode. To help prevent fire  
and explosion:  
Do not spray flammable or combustible materials near an open flame or sources of ignition such as cig-  
arettes, motors, and electrical equipment.  
Paint or solvent flowing through the equipment is able to result in static electricity. Static electricity cre-  
ates a risk of fire or explosion in the presence of paint or solvent fumes. All parts of the spray system,  
including the pump, hose assembly, spray gun, and objects in and around the spray area shall be prop-  
erly grounded to protect against static discharge and sparks. Use Graco conductive or grounded  
high-pressure airless paint sprayer hoses.  
Do not clean with materials having flash points lower than 70° F (21° C). Use water-based material or  
mineral spirits-type material only. For complete information about your fluid, request the MSDS from the  
fluid distributor or retailer.  
Verify that all containers and collection systems are grounded to prevent static discharge.  
Connect to a grounded outlet and use grounded extensions cords. Do not use a 3-to-2 adapter.  
Do not use a paint or a solvent containing halogenated hydrocarbons.  
Keep spray area well-ventilated. Keep a good supply of fresh air moving through the area. Keep pump  
assembly in a well ventilated area. Do not spray pump assembly.  
Do not smoke in the spray area.  
Do not operate light switches, engines, or similar spark producing products in the spray area.  
Keep area clean and free of paint or solvent containers, rags, and other flammable materials.  
Know the contents of the paints and solvents being sprayed. Read all Material Safety Data Sheets  
(MSDS) and container labels provided with the paints and solvents. Follow the paint and solvents manu-  
facturer’s safety instructions.  
Fire extinguisher equipment shall be present and working.  
Sprayer generates sparks. When flammable liquid is used in or near the sprayer or for flushing or clean-  
ing, keep sprayer at least 20 feet (6 m) away from explosive vapors.  
SKIN INJECTION HAZARD  
Do not aim the gun at, or spray any person or animal.  
Keep hands and other body parts away from the discharge. For example, do not try to stop leaks with  
any part of the body.  
Always use the nozzle tip guard. Do not spray without nozzle tip guard in place.  
Use Graco nozzle tips.  
Use caution when cleaning and changing nozzle tips. in the case where the nozzle tip clogs while spray-  
ing, follow the Pressure Relief Procedure for turning off the unit and relieving the pressure before  
removing the nozzle tip to clean.  
Do not leave the unit energized or under pressure while unattended. When the unit is not in use, turn off  
the unit and follow the Pressure Relief Procedure for turning off the unit.  
High-pressure spray is able to inject toxins into the body and cause serious bodily injury. In the event  
that injection occurs, get immediate surgical treatment.  
Check hoses and parts for signs of damage. Replace any damaged hoses or parts.  
This system is capable of producing 3300 psi. Use Graco replacement parts or accessories that are  
rated a minimum of 3300 psi.  
Always engage the trigger lock when not spraying. Verify the trigger lock is functioning properly.  
Verify that all connections are secure before operating the unit.  
Know how to stop the unit and bleed pressure quickly. Be thoroughly familiar with the controls.  
4
3A0156A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Warnings  
WARNING  
EQUIPMENT MISUSE HAZARD  
Misuse can cause death or serious injury.  
Always wear appropriate gloves, eye protection, and a respirator or mask when painting.  
Do not operate or spray near children. Keep children away from equipment at all times.  
Do not overreach or stand on an unstable support. Keep effective footing and balance at all times.  
Stay alert and watch what you are doing.  
Do not leave the unit energized or under pressure while unattended. When the unit is not in use, turn off  
the unit and follow the Pressure Relief Procedure for turning off the unit.  
Do not operate the unit when fatigued or under the influence of drugs or alcohol.  
Do not kink or over-bend the hose.  
Do not expose the hose to temperatures or to pressures in excess of those specified by Graco.  
Do not use the hose as a strength member to pull or lift the equipment.  
ELECTRIC SHOCK HAZARD  
This equipment must be grounded. Improper grounding, setup, or usage of the system can cause electric  
shock.  
Turn off and disconnect power at main switch before disconnecting any cables and before servicing  
equipment.  
Connect only to grounded power source.  
All electrical wiring must be done by a qualified electrician and comply with all local codes and regula-  
tions.  
PRESSURIZED ALUMINUM PARTS HAZARD  
Use of fluids that are incompatible with aluminum in pressurized equipment can cause serious chemical  
reaction and equipment rupture. Failure to follow this warning can result in death, serious injury, or property  
damage.  
Do not use 1,1,1-trichloroethane, methylene chloride, other halogenated hydrocarbon solvents or fluids  
containing such solvents.  
Many other fluids may contain chemicals that can react with aluminum. Contact your material supplier  
for compatibility.  
MOVING PARTS HAZARD  
Moving parts can pinch, cut or amputate fingers and other body parts.  
Keep clear of moving parts.  
Do not operate equipment with protective guards or covers removed.  
Pressurized equipment can start without warning. Before checking, moving, or servicing equipment, fol-  
low the Pressure Relief Procedure and disconnect all power sources.  
PERSONAL PROTECTIVE EQUIPMENT  
You must wear appropriate protective equipment when operating, servicing, or when in the operating area of  
the equipment to help protect you from serious injury, including eye injury, hearing loss, inhalation of toxic  
fumes, and burns. This equipment includes but is not limited to:  
Protective eyewear, and hearing protection.  
Respirators, protective clothing, and gloves as recommended by the fluid and solvent manufacturer.  
3A0156A  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Component Identification  
Component Identification  
13.  
12.  
1.  
2.  
3.  
11.  
4.  
5.  
9.  
8.  
10.  
6.  
7.  
ti14839a  
1
2
3
Premium Digital Display  
ON/OFF Switch  
WatchDog Switch (not available on Mark V or Standard Units)  
4
5
6
7
8
9
Pressure Control  
Prime / Spray Valve  
Filter  
Siphon Tube  
Pump  
Bearing Housing / ProConnect  
10 Drain Tube  
11 Trigger Lock  
12 Model/Serial Tag  
13 Hose Reel  
6
3A0156A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Grounding  
Grounding  
The sprayer must be grounded. Grounding reduces the  
risk of static and electric shock by providing an escape  
wire for the electrical current due to static build up or in  
the event of a short circuit.  
Pails  
The sprayer cord includes a grounding wire with an  
appropriate grounding contact.  
Solvent and oil/based fluids: follow local code. Use  
only conductive metal pails, placed on a grounded sur-  
face such as concrete.  
Do not place pail on a nonconductive surface such as  
paper or cardboard which interrupts grounding continu-  
ity.  
The plug must be plugged into an outlet that is properly  
installed and grounded in accordance with all local  
codes and ordinances.  
ti5850a  
Grounding a metal pail: connect a ground wire to the  
pail by clamping one end to pail and other end to a true  
earth ground.  
ti2810a  
ti4297a  
Do not modify plug! Tampering with the plug will result in  
a voided warranty. If plug will not fit in outlet, have  
grounded outlet installed by a qualified electrician. Do  
not use an adapter.  
Power Requirements  
100-120V units require 100-120 VAC, 50/60 Hz,  
15A, 1 phase.  
ti14840a  
230V units require 230 VAC, 50/60 HZ,  
10A, 1 phase.  
To maintain grounding continuity when flushing or  
relieving pressure: hold metal part of spray gun firmly  
to side of a grounded metal pail. Then trigger gun.  
Extension Cord  
Use an extension cord with an undamaged ground con-  
tact. If an extension cord is necessary, use a 3-wire, 12  
2
AWG (2.5 mm ) minimum.  
Ground  
ti13243a  
120 volt plug  
3A0156A  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
15/20 Amp Switch (Not Available on All Units)  
15/20 Amp Switch (Not Available on All Units)  
20  
ti14919a  
Select 15A or 20A setting based on your circuit rating.  
Pressure Relief Procedure  
3. Turn pressure to lowest setting. Trigger gun to  
relieve pressure.  
1. Turn power OFF. Wait 7 seconds for power to  
dissipate.  
ti14841a  
ti4265a  
-
4. Put drain tube in pail. Turn prime valve down to  
DRAIN position.  
2. Lock gun trigger safety. Remove guard and  
SwitchTip.  
ti14842a  
ti2595a  
ti2769a  
ti10166a  
8
3A0156A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Setup  
Setup  
6. Fill throat packing nut with Graco TSL to prevent  
premature packing wear. Do this each time you  
spray.  
1. Standard Units Only: Connect Graco airless hose  
to sprayer. Tighten securely.  
ti13453a  
7. Turn power OFF.  
ti14843a  
ti4265a  
2. Standard Units Only: Connect other end of hose  
to gun and tighten securely.  
ti4265a  
8. Plug power supply cord into a properly grounded  
electrical outlet.  
ti2810a  
ti13031a  
3. Engage gun trigger safety.  
9. Turn prime valve down to DRAIN position.  
ti10166a  
4. Remove tip guard.  
ti14842a  
10. Place pump in grounded metal pail partially filled  
with flushing fluid. Attach ground wire to pail and  
to true earth ground. Perform steps 1 - 5 of Startup  
to flush out storage oil shipped in sprayer. Use water  
to flush water-base paint and mineral spirits to flush  
oil-base paint and storage oil.  
ti2769a  
5. Check inlet strainer for clogs and debris.  
ti14844a  
3A0156A  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
Startup  
Startup  
5. Hold gun against grounded metal flushing pail. Trig-  
ger gun and increase fluid pressure 1/2 turn. Flush  
1 minute.  
1
/
1. Turn pressure control to lowest pressure.  
2
ti13243a  
ti4271a  
6. Inspect for leaks. Do not stop leaks with hand or a  
rag! If leaks occur, perform Pressure Relief Proce-  
dure, page 8. Tighten fittings. Perform Startup,  
steps 1 - 5. If no leaks, proceed to step 7.  
2. Turn power ON.  
ti4266a  
7. Place pump in paint pail.  
ti4266a  
ti2714a  
3. Increase pressure 1/2 turn to start motor and allow  
fluid to circulate through drain tube for 15 seconds;  
turn pressure down.  
PAINT  
8. Trigger gun again into flushing pail until paint  
appears. Move gun to paint pail and trigger for 20  
seconds. Set gun safety ON. Assemble tip and  
guard, see instructions on next page.  
15sec.  
1/2  
4. Turn prime valve forward to SPRAY position. Disen-  
gage gun trigger safety.  
ti10166a  
ti13029a  
ti10167a  
ti14845a  
10  
3A0156A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Switch Tip Installation  
Switch Tip Installation  
Spray  
1. Spray test pattern. Increase pressure to eliminate  
heavy edges. Use smaller tip size if pressure adjust-  
ment can not eliminate heavy edges.  
1. Use spray tip (A) to insert OneSeal (B) into  
guard (C).  
C
A
B
ti13030a  
ti13023a  
2. Hold gun perpendicular, 10-12 in. (25-30 cm) from  
surface. Spray back and forth. Overlap by 50%. Trig-  
ger gun after moving and release before stopping.  
2. Insert Switch Tip.  
ti13024a  
ti13025a  
3. Screw assembly onto gun. Tighten.  
Clearing Tip Clog  
1. Release trigger, put safety ON. Rotate SwitchTip.  
Take safety OFF. Trigger gun to clear clog. Never  
point gun at your hand or into a rag!  
ti2710a  
ti13033a  
ti10166a  
ti10167a  
2. Put safety ON. Return SwitchTip to original position.  
Take safety OFF and continue spraying.  
ti10167a  
ti13034a  
ti10166a  
3A0156A  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
WatchDog Protection System (Not Available on All Units)  
WatchDogProtection  
System (Not Available on All Units)  
Pump stops automatically when material pail is empty.  
To Activate:  
Fast Flush  
1. Perform Startup.  
To flush the hose and gun at an accelerated speed, per-  
form the following steps:  
1. Perform steps 1 - 3 of Cleanup, page 16.  
2. Hold gun trigger in and turn prime valve down to  
DRAIN position and then over to FAST FLUSH.  
ti7398a  
2. Premium units with digital display:  
Turn WatchDog switch ON and WD ON displays.  
EMPTY displays/flashes and pump stops when  
Watchdog protection system detects an empty  
material pail.  
ti14849a  
3. Continue flushing system until fluid appears clear.  
ti6224a  
3. Turn WatchDog switch OFF. Add material or reprime  
sprayer. Turn pump switch OFF and ON to reset  
WatchDog protection system. Turn WatchDog  
switch back ON to continue to monitor material  
level.  
ti7399a  
TIꢀꢁꢂꢂA  
12  
3A0156A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hose Reel (Not Available on All Units)  
Hose Reel (Not Available on All Units)  
3. Pull reel handle up and turn clockwise to reel in  
hose.  
Be sure to keep your head clear of hose reel while  
winding up hose.  
1. Make sure hose is routed through hose guide.  
ti13502a  
ti13503a  
NOTE: The hose reel can be locked into two positions:  
Usage (A) and Storage (B).  
(A)  
(B)  
ti13504a  
2. Lift and turn pivot lock 90° to unlock hose reel. Pull  
on hose to remove it from hose reel.  
ti13563a  
ti13501a  
3A0156A  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Digital Tracking System (Not Available on All Units)  
Digital Tracking System (Not Available on All Units)  
Operation Main Menu  
Job Gallons  
Short press to move to next display. Press and hold (5  
seconds) to change units or reset data.  
1. Short press DTS button to move to Job Gallons (or  
liters x 10).  
Psi  
ti13612a  
ti13620a  
ti13605a  
ti13610a  
1. Turn pressure to lowest setting. Trigger gun to  
relieve pressure. Turn prime valve down to DRAIN  
position.  
NOTE: JOB scrolls past, then the number of gallons  
sprayed above 1000 psi (70 bar, 7 MPa) displays.  
2. Press and hold to reset to zero.  
Lifetime Gallons  
1. Short press DTS button to move to Lifetime Gallons  
(or liters x 10).  
ti14842a  
-
ti13243a  
NOTE: LIFE scrolls briefly, then the number of gal-  
lons sprayed above 1000 psi (70 bar, 7 MPa) dis-  
plays.  
2. Turn power ON. Pressure display appears. Dashes  
will not appear unless pressure is less than 200 psi  
(14 bar, 1,4 MPa).  
ti4266a  
OR  
ti13601a  
ti13617a  
ti13611a  
psi  
ti13621a  
Change Display Units  
Press and hold DTS button for 5 seconds to change  
pressure units (psi, bar, MPa) to desired units. Selec-  
tion of bar or MPa changes gallons to liters x 10. To  
change display units DTS must be in pressure display  
mode and pressure must be at zero.  
Psi  
Psi  
bar  
ti13620a  
MPa  
ti13604a  
14  
3A0156A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Digital Tracking System (Not Available on All Units)  
Secondary Menu - Stored Data and  
WatchDog Pump Protection Modes  
1. Perform Pressure Relief, steps 1 - 4 if they have  
7. Short press DTS button. W-DOG scrolls past then  
OFF displays if watchdog switch is OFF. ON dis-  
plays if Watchdog switch is ON.  
not already been done.  
2. Turn power switch on while holding DTS button  
down.  
ti4266a  
ti13608a  
ti13626a  
ti13605a  
ti13614a  
3. SERIAL NUMBER scrolls past and then serial num-  
ber (e.g. 00001) displays.  
8. Press and hold (8 seconds) DTS button to move to  
WatchDog Trigger % menu. Continue to hold DTS  
button and Watchdog can be set to trigger at 30, 40,  
50, or 60% of current sprayer pressure setting.  
Release DTS button when desired % is displayed.  
Default is 50%.  
ti13622a  
ti7362a  
4. Short press DTS button and MOTOR HOURS  
scrolls past and then total motor run hours are dis-  
played.  
ti13618a  
TIꢀꢁꢂꢃA  
9. Short press to move to SOFTWARE REV.  
ti13619a  
5. Short press DTS button. LAST ERROR CODE  
scrolls by and last error code is displayed; e.g. E=07  
(see Repair manual).  
ti13613a  
ti13623a  
10. Short press DTS button. MOTOR ID RESISTOR  
ti13601a  
ti13615a  
scrolls by and model code number (see below).  
Code Number  
Models  
0
2
4
6
695  
ti13607a  
795 / MARK IV  
1095 / 220V MARK V  
1595 / 120V MARK V  
6. Press and hold DTS button to clear error code to  
zero.  
ti13609a  
ti13606a  
3A0156A  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Cleanup  
Cleanup  
5. Turn prime valve down to DRAIN position and allow  
flushing fluid to circulate until flushing fluid appears  
clear.  
1. Perform Pressure Relief Procedure (page 8),  
steps 1 - 4. Remove siphon tube set from paint and  
place in flushing fluid. Remove tip guard from gun.  
ti14842a  
6. Turn prime valve forward to SPRAY position. Trigger  
gun into flushing pail to purge fluid from hose.  
ti2756a  
NOTE: Use water for water-base paint, mineral spirits  
for oil-base paint, or other solvents recommended by  
manufacturer.  
2. Turn power ON. Turn prime valve forward to SPRAY  
ti14847a  
ti14845a  
position.  
ti4266a  
7. Raise siphon tube above flushing fluid and run  
sprayer for 15 to 30 seconds to drain fluid. Turn  
power OFF  
ti14845a  
3. Increase pressure to 1/2. Hold gun against paint  
pail. Take trigger safety OFF. Trigger gun until flush-  
ing fluid appears.  
1
/
2
PAINT  
ti2820a  
FLUSH  
8. Turn prime valve down DRAIN position. Unplug  
sprayer.  
ti14846a  
ti4271a  
4. Move gun to waste pail, hold gun against pail, trig-  
ger gun to thoroughly flush system. Release trigger  
and put trigger safety ON.  
ti2718a  
ti14842a  
ti14847a  
16  
3A0156A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Cleanup  
9. Remove filters from gun and sprayer, if installed.  
Clean and inspect. Install filters.  
ti15018a  
10. If flushing with water, flush again with mineral spirits,  
or Pump Armor, to leave a protective coating to pre-  
vent freezing or corrosion.  
ti2895a  
Pump Armor  
11. Wipe sprayer, hose and gun with a rag soaked in  
water or mineral spirits.  
ti2776a  
3A0156A  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Technical Data  
Technical Data  
Fluid  
Motor HP Cycles per Maximum Delivery Maximum Outlet  
100 - 120V, 220 - 240V,  
Generator  
Model  
695  
A, Hz  
A, Hz  
Minimum W  
(W)  
gallon (liter)  
gpm (lpm)  
Tip Size  
npsm  
14.8,  
50/60  
9,  
50/60  
5000  
5000  
5000  
5000  
5000  
5000  
5000  
2.0  
(1490)  
226  
(60)  
0.95  
(3.6)  
0.031  
1/4 in.  
15,  
50/60  
10,  
50/60  
2.2  
(1640)  
195  
(52)  
1.1  
(4.2)  
0.033  
0.033  
0.035  
0.037  
0.039  
0.039  
1/4 in.  
3/8 in.  
1/4 in.  
3/8 in.  
1/4 in.  
3/8 in.  
795  
15,  
50/60  
N/A  
2.2  
(1640)  
195  
(52)  
1.1  
(4.2)  
Mark IV  
1095  
15,  
50/60  
10,  
50/60  
2.4  
(1790)  
123  
(33)  
1.2  
(4.5)  
N/A  
10,  
50/60  
2.4  
(1790)  
110  
(29)  
1.3  
(4.9)  
Mark V  
1595  
20/15,  
50/60  
N/A  
2.8  
(2090)  
110  
(29)  
1.35  
(5.1)  
20/15,  
50/60  
N/A  
2.8  
(2090)  
110  
(29)  
1.35  
(5.1)  
Mark V  
Basic Sprayer Wetted Parts..............................  
zinc- and nickel-plated carbon steel, nylon, stainless  
steel, PTFE, Acetel, leather, UHMWPE, aluminum  
tungsten carbide, PEEK, brass  
Noise Level  
Sound power ...............................................91 dBa*  
Sound pressure .........................................82 dBa*  
*per ISO 3744; measured at 3.1 feet (1 m)  
Dimensions  
Weight lb  
(kg)  
Height in.  
(cm)  
Length in.  
(cm)  
Model  
Width  
in (cm)  
Lo-Boy Hi-Boy QuikReel  
Lo-Boy Hi-Boy QuikReel Lo-Boy  
Hi-Boy  
QuikReel  
94  
(43)  
94  
(43)  
111  
(50)  
27.5  
(69.9)  
28.5 (72.4) Handle down,  
38.75 (98.4) Handle up  
39  
(99)  
37  
(94)  
26  
(66)  
29.5  
(75)  
22.5  
(57.2)  
695  
795  
98  
(45)  
98  
(45)  
115  
(52)  
27.5  
(69.9)  
28.5 (72.4) Handle down,  
38.75 (98.4) Handle up  
39  
(99)  
37  
(94)  
26  
(66)  
29.5  
(75)  
22.5  
(57.2)  
N/A  
N/A  
N/A  
N/A  
N/A  
119  
(54)  
N/A  
N/A  
N/A  
N/A  
N/A  
39  
(99)  
N/A  
N/A  
N/A  
N/A  
N/A  
29.5  
(75)  
22.5  
(57.2)  
Mark IV  
1095  
120  
(55)  
141  
(64)  
29.5 (74.9) Handle down,  
38.5 (97.8) Handle up  
39  
(99)  
26  
(66)  
28  
(71)  
24  
(61)  
125  
(57)  
146  
(66)  
29.5 (74.9) Handle down,  
38.5 (97.8) Handle up  
39  
(99)  
26  
(66)  
28  
(71)  
22.5  
(57.2)  
1595  
130  
(59)  
151  
(68)  
29.5 (74.9) Handle down,  
38.5 (97.8) Handle up  
39  
(99)  
26  
(66)  
28  
(71)  
24  
(61)  
Mark V  
18  
3A0156A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Notes  
Notes  
3A0156A  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Warranty  
Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in  
material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty  
published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by  
Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written  
recommendations.  
This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty  
installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of  
non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with  
structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or  
maintenance of structures, accessories, equipment or materials not supplied by Graco.  
This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of  
the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned  
to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will  
be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.  
THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED  
TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.  
Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy  
(including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or  
consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.  
GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A  
PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT  
MANUFACTURED BY GRACO. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to  
the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these  
warranties.  
In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or  
the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the  
negligence of Graco, or otherwise.  
FOR GRACO CANADA CUSTOMERS  
The Parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into,  
given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la  
rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés, à la suite  
de ou en rapport, directement ou indirectement, avec les procédures concernées.  
TO PLACE AN ORDER, contact your Graco distributor or call 1-800-690-2894 to identify the nearest distributor.  
All written and visual data contained in this document reflects the latest product information available at the time of publication.  
Graco reserves the right to make changes at any time without notice.  
This manual contains English. MM 3A0156  
Graco Headquarters: Minneapolis  
International Offices: Belgium, China, Japan, Korea  
GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440-1441  
Copyright 2009, Graco Inc. is registered to ISO 9001  
2009  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Graco Car Seat PD220791A 8 12 User Manual
Haier Air Conditioner HWVR08XCK User Manual
Hamilton Beach Toaster 22811 User Manual
Harbor Freight Tools Portable Generator 65309 User Manual
Hasbro Games GI Joe Voice FX Duke User Manual
Hotpoint Ventilation Hood HTU30 User Manual
HP Hewlett Packard Personal Computer 6 PC User Manual
Husqvarna Tiller CT20 User Manual
IBM Personal Computer X3200 M3 User Manual
Image Treadmill 831297570 User Manual