O W N E R ’ S M A N U A L
GP-SW050
Residential Duty Swing Gate Operator
With Inherent UPS Battery Back-up System
TWO 12VDC, U1, 230A BATTERIES ARE REQUIRED BUT NOT INCLUDED.
DO NOT Install This Operator Without Safety Edges and Photo Beams!
APPROPRIATE ENTRY/EXIT DEVICES WILL BE REQUIRED - SEE YOUR DEALER.
This product meets and exceeds the requirements of UL 325 gate operator safety standards.
US
Download from Www.Somanuals.com. All Manuals Search And Download.
table of contents
Gate Operator Class Categories ......................................................................................Inside Cover
Metric Conversion Chart..........................................................................................................................Inside Cover
Safety Instructions for the GP-SW050 Swing Gate Operators....................................................1
Important Safety Instructions for the System Designer.....................................................................................1
Important Safety Instructions for the Installer......................................................................................................2
Important Safety Instructions Specific to Secondary Means of Protection Against Entrapment.......3
Important Safety Instructions for the Consumer/End User..............................................................................4
Required Safety Precautions for Gates.....................................................................................................................5
Warning Labels ................................................................................................................................................................6
Technical Specifications ..........................................................................................................................7
Parts Identification.....................................................................................................................................8
Installing the Gate Operator...................................................................................................................9
Preparation of the Gate..................................................................................................................................................9
Operator Installation Overview ..................................................................................................................................9
Using the Mounting Template ............................................................................................................................... 10
Mounting Template (not to scale) ......................................................................................................................... 11
Removing the Operator Housing .......................................................................................................................... 12
Mounting the Operator ............................................................................................................................................ 12
Connecting Power to the Operator ...................................................................................................................... 13
Connecting the Gate Arm Assembly...................................................................................................................... 14
Connecting Gate Arm to The Gate ........................................................................................................................ 15
Control Board Description......................................................................................................................................... 16
Setting The Limits ......................................................................................................................................................... 17
Stall Force and Auto-Close Adjustments.............................................................................................................. 18
DIP Switch Settings ...................................................................................................................................................... 19
Input Connections........................................................................................................................................................ 20
Accessory Terminal Connections............................................................................................................................. 21
Output Connections .................................................................................................................................................... 22
Accessory Power Supply............................................................................................................................................. 23
Prison Mode Operation and Wiring A 3-Button Station.................................................................................. 24
Reinstalling the Operator Housing ..................................................................................................................... 25
Installing a Dual System.........................................................................................................................26
Setting Dual Gate Sequence................................................................................................................27
Overview of a Dual Gate Operator Installation .............................................................................28
Maintenance ..............................................................................................................................................29
Troubleshooting Guide..........................................................................................................................30
Warranty and Repair Service ...............................................................................................................33
Installation Checklist............................................................................................................. Back Cover
Download from Www.Somanuals.com. All Manuals Search And Download.
Important Safety Instructions
SAFETY INSTRUCTIONS FOR ThE GP-SW050 SWING GATE OPERATORS
Because automatic gate operators produce high levels of force, all system designers, installers, and consumers
have an obligation to know the potential hazards associated with improperly designed, installed, or maintained
gate operator systems. Keep in mind that the gate operator is just one component of the total gate operating system.
Each component must work in unison to provide the consumer with convenience, security, and safety.
This manual contains various safety precautions and warnings for the system designer, installer, and consumer.
Becausetherearemanypossibleapplicationsofthegateoperator,thesafetyprecautionsandwarningscontained
in this manual cannot be completely exhaustive in nature. They do, however, provide an overview of the safe
design, installation, and use of this product. CAREFULLY READ AND FOLLOW ALL SAFETY PRECAUTIONS,
WARNINGS, AND INSTALLATION INSTRUCTIONS TO ENSURE THE SAFE SYSTEM DESIGN, INSTALLATION,
AND USE OF THIS PRODUCT.
The precautions and warnings in this manual are identified with these
warning symbols.
symbol identifies the conditions that can result in serious injury or death from electrical shock.
symbol identifies the conditions that can result in damage to the operator or its components, serious
This
This
injury, or death.
BecauseGTOautomaticgateoperatorsareonlypartofthetotalgateoperatingsystem,itistheresponsibility
of the designer, installer, and purchaser to ensure the total system is safe for its intended use. Bypassing
safety devices or neglecting to use safety devices with the gate operator is NOT acceptable.
ImPORtant Safety InStRUctIOnS for the System Designer
WARNING: To reduce the risk of injury or death:
1. READ AND FOLLOW ALL INSTRUCTIONS.
2. Thisoperatorisintendedforuseonlyonvehiculargates.Pedestriansmustbesuppliedwithaseparate
walk-through gate (see Entrapment Protection on page 5).
3. When designing a system that will be entered from a highway or main thoroughfare, make sure the
system is placed far enough from the road to prevent traffic congestion.
1
Download from Www.Somanuals.com. All Manuals Search And Download.
Important Safety Instructions
ImPORtant Safety InStRUctIOnS For the Installer
WARNING–To reduce the risk of injury or death:
I. Before Installation
1. READ AND FOLLOW ALL INSTRUCTIONS.
2. Verify this operator is proper for the type and size of gate, and its frequency of use.
3. Make sure that the gate has been properly installed and swing freely in both directions. Repair or replace
all worn or damaged gate hardware prior to installation. A freely moving gate will require less force to
operate and will enhance the performance of the operator and safety devices used with the system.
4. for pedestrian use (see page 5). NO ONE SHOULD CROSS THE PATH OF A MOVING GATE.
II. During Installation
1. Install the gate operator on the inside of the property and fence line. DO NOT install an operator on the
outside of the gate where the public has access to it.
2. Be careful with moving parts and avoid close proximity to areas where fingers or hands could
be pinched.
3. Determine the best obstruction sensing setting for this installation. The gate MUST stop and reverse
on contact with an obstruction. After adjusting the force or the limit of travel, retest the gate operator.
Failure to adjust and retest the gate operator properly can increase the risk of injury or death
(see page 18).
4. Additional safety equipment such as photo beams and safety edges MUST be installed to prevent
bodily injury (see page 9).
5. Mount access controls away from the gate (minimum distance is 10 feet). The user must have full view
of the gate but be unable to touch it while operating the controls.
6. Secure outdoor or easily accessed gate operator controls in order to prohibit unauthorized use of
the gate.
III. After Installation
1. Review ALL safety instructions with the consumer/end user and explain the basic operation and safety
systems of the entire gate operator system.
2. Inform the consumer/end user that servicing of the operator must only be done by an
experienced technician.
3. Attach the warning signs (included) to each side of the gate to alert public of automatic gate operation.
Take a photo of warning signs installed on gate. Record the date of the photo for your reference.
4. SAVE THESE INSTRUCTIONS. Leave IMPORTANT SAFETY INSTRUCTIONS (included)
with consumer/end user.
2
Download from Www.Somanuals.com. All Manuals Search And Download.
Important Safety Instructions
ImPORtant Safety InStRUctIOnS Specific to Secondary
Means of Protection Against Entrapment
As specified by Underwriters Laboratories Inc. UL 325 (30A.1.1), automatic gate operators shall have provisions
for, or be supplied with, at least one independent primary and one independent secondary means to protect
against entrapment. GTO gate operators utilize Type A, an inherent entrapment sensing system, as the primary
type of entrapment protection. The GP-SW050 operators have provisions for the connection of Type B1, B2, or
D protection to be used as the secondary type of entrapment protection.
1. For gate operators utilizing a non-contact sensor (Type B1) in accordance with UL 325 (51.8.4 [h]):
A. Refer to the sensor manufacturer’s instructions on the placement of non-contact sensors for each type of
application.
B. Care shall be exercised to reduce the risk of nuisance tripping, such as when a vehicle trips the sensor
while the gate is still moving.
C. One or more non-contact sensors shall be located where the risk of entrapment or obstruction exists,
such as the perimeter reachable by a moving gate or barrier.
2. For gate operators utilizing a contact sensor (Type B2) in accordance with UL 325 (51.8.4 [i]):
A. One or more contact sensors shall be located at the leading edge, trailing edge, and post mounted both
inside and outside of a vehicular swing gate system.
B. Ahard wired contactsensorshall belocatedandits wiring arranged so that the communication between
the sensor and the gate operator is not subjected to mechanical damage.
C. A wireless contact sensor such as one that transmits radio frequency (RF) signals to the gate operator
for entrapment protection functions shall be located where the transmission of the signals are not
obstructed or impeded by building structures, natural landscaping or similar obstruction. A wireless
contact sensor shall function under the intended end-use conditions.
3. For gate operators utilizing an actuating device requiring continuous pressure to maintain opening or
closing motion of the gate (Type D) in accordance with UL 325 (51.8.4 [e]):
A. The gate operator controls must be placed so that the user has full view of the gate area when the gate
is moving.
B. Warning signs (see page 6) shall be placed adjacent to the controls.
C. No other activation device shall be connected.
ENTRAPMENT ALARM (UL 325; 30A.1.1A)
The GP-SW050 operators are designed to stop and reverse for 2 seconds when the gate comes in contact
with an obstruction or when an object activates the non-contact sensors. Additionally, these operators
are equipped with an audio entrapment alarm which will function if the unit obstructs twice while
opening or closing. This alarm will sound for a period of 5 minutes or until the operator receives an
intended signal (e.g., transmitter signal) and the gate returns to a fully open or fully closed position.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Important Safety Instructions
important safety instructions for the Consumer/End User
WARNING: To reduce the risk of injury or death:
1. READ AND FOLLOW ALL INSTRUCTIONS.
2. Distribute and discuss copies of the IMPORTANT SAFETY INSTRUCTIONS manual with all persons
authorized to use your gate. SAVE THESE INSTRUCTIONS.
3. Always keep people and objects away from the gate and its area of travel.
NO ONE SHOULD CROSS THE PATH OF THE MOVING GATE.
4. Your automatic gate is not for pedestrian use. If pedestrian traffic is expected near the gate, a walk-
through gate must be installed for this purpose (see page 5).
5. Do not allow children or pets near your gate. Never let children operate or play with gate controls.
Keep the remote controls away from children and unauthorized users; store controls where children and
unauthorized users do not have access to them.
6. Ifpushbuttonsorkeyswitchesareinstalled,theyshouldbewithinsightofthegate,yetlocatedfarenough
from the gate (at least 10 feet) so the gate cannot be touched while in operation. Do not operate any
control without watching the movement of the gate.
7. Do not activate your gate operator unless you can see it and can determine that its area of travel is clear
of people, pets, or other obstructions.
8. It is your responsibility to make sure that the installer posted warning signs on both sides of your gate. If
any of these signs or warning decals become damaged, illegible or missing, replace them immediately.
Contact your installer or GTO for replacements.
9. Verify that electric safety edge sensors or photoelectric sensors have been installed (see page 5). These
safety devices should be tested monthly.
10. KEEP GATES PROPERLY MAINTAINED. Have a qualified service person make repairs to the gate hardware.
NEVER REMOVE THE OPERATOR HOUSING.
11. DANGER:HIGHVOLTAGE!Contactwithgateoperatorcircuitrycancauseseriousinjuryordeath! DO
NOT attempt to service this operator yourself; for service, contact your installer or another experienced
technician.
12. Have your gate operator tested monthly and serviced regularly by an experienced technician. The gate
MUST stop and reverse on contact with an obstruction or when an object activates the non-contact
sensors.Ifthesefunctionsareobservedtooperateimproperly,discontinueuseandhaveoperatorserviced
immediately.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
Important Safety Instructions
required safety Precautions for gates
Entrapment Protection
GTO’sinternalobstructionsettings, evenwhenproperlyadjusted, maynotbesensitiveenoughtopreventbodily
injury. For this reason, safety devices such as safety edges and photo beams MUST be installed. Furthermore,
a walk-through gate must be installed if pedestrian traffic is expected near the gate. We recommend the GTO
Bulldog Pedestrian Gate Lock (available as an accessory) for controlled access.
Pedestrian Gate
Safety Edge
Safety Edge
Warning Sign
Operator
Vehicle Gate
Photo Beams
Safety Edge
Photo Beams
!
WARNING
Warning Signs
The warning signs (with orange panel)
must be installed on both sides of the
gate.
Moving Gate Can Cause
Injury Or Death
1. KEEP CLEAR! Gate may move at any time.
2. Do not allow children to operate gate or
play in gate area.
3. This gate is for vehicles only. Pedestrians
must use a separate entrance.
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Important Safety Instructions
Warning labels
These warning signs and labels should be found at the locations specified below. If any of them are missing,
immediately contact your installer for replacements.
!
WARNING
Moving Gate Can Cause
Injury Or Death
1. KEEP CLEAR! Gate may move at any time.
2. Do not allow children to operate gate or
play in gate area.
3. This gate is for vehicles only. Pedestrians
must use a separate entrance.
Warning signs (2) to be installed on each side of the gate
(3–5 feet above the bottom of the gate)
GTO AC GP-SW050 SERIES
Conforms to UL 325 STANDARDS
Maximum Gate: 650 lb. (295.4 kg); 16 ft. (4.9 m)
US Voltage: 110 Vac; Frequency: 60 Hz; Power: 300 W
Class I, II, III and IV Vehicular Swing Gate Operator.
Serial Number: XXXXXXXXXX
C
I
#xxxxxxx
TO MANUALLY OPEN AND CLOSE THE GATE:
1. Turn control box power switch OFF.
2. Disconnect operator arm from gate brackets.
3. Manually swing gate to desired position.
Disconnect operator ONLY when the control box
power switch is OFF and the gate is NOT moving.
xx/xx/xx
GTO, Inc. Tallahassee, Florida USA
GP-SW050
Product identiꢀcation and manual operation instruction
label (1) installed on cover.
6
Download from Www.Somanuals.com. All Manuals Search And Download.
technical specifications
Motor
• Brushless DC motor 24VDC 300 watts
• ½ Horsepower
• Maximum motor current 20Amp
• 2500 RPM
• Open and close time for 90° opening is approximately 15 seconds
gear reducer
• Aluminum Cased 1200:1, size 40/63, compound, worm reducer with ball bearings.
• Permanently lubricated with synthetic gear oil – oil specifications 5w-30, Mobil 1 recommended
Power
• 120 vac @60 Hz with inherent 24 vdc battery backup
• Batteries are required – two 12 vdc, U1, 230A minimum cold crank amps wired together in series.
• 100 cycles in backup typical for minimum size battery.
• 15 amp circuit breaker on dedicated circuit
• On board 120 vac outlet for accessories that pull no more than 1 amp of current
control
• Microcontroller based logic control board
• Adjustable autoclose
• Independent obstruction settings
• Diagnostic LED’s & Audible Alarms
• Accessory terminals compatible with loop detectors, photo beams, edge sensors, push buttons, card readers, exit wands, etc.
• Relay Outputs
• On board Open and Closed Stop buttons
• Jog Buttons
construction
• Heavy duty steel frame
• Rotomolded UV stabilized HDPE cover
operational capacity
• Continuous duty operations
• Max rating: 16 ft gate @ 650 lbs
• Dual Gate compatible using two conductor 22 AWG shielded wire rated for direct burial. Recommended
Belden Wire®, 22 AWG, type 8761, 9461, 9451, 1266A or equivalent. 1-pair shielded with drain wire. Available at your
local electrical supply store.
Dimensions
• Housing Dimensions: height 33 in (68.7 cm), depth 18 in (45.7 cm), width 15 in (38 cm), shipping weight: 130 lbs
• Concrete Pad Dimensions: 18 in x 18 in, (45.7 cm x 45.7 cm). Consult local building codes for depth below
ground level. Absolute minimum depth 30 in (76.2 cm) below ground level.
operational temperature:
• In colder climates (ambient temperatures less than 10 degrees) GTO recommends the use of a thermostatically
controlled heating source (ceramic heating strips, etc.) on the batteries and gearbox assembly. Styles, types,
and power requirements of heating devices will vary by climate and region.
Warranty:
• Residential (7) years for mechanical parts, (5) years electronic components
• Commercial (5) years for mechanical parts, (3) years electronic components
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Parts identification
Fully Assembled Operator
Operator Chassis
12½ in
(31.8 cm)
13 in
(33 cm)
17 in
(42 cm)
27 in
23¾ in
(60.3 cm)
(69 cm)
19¾ in
(50.2 cm)
24 in
33 in
(61 cm)
(84 cm)
TO
BASE
18 in
6 in
(15.2 cm)
(46 cm)
14½ in
(36.8 cm)
12½ in
(31.8 cm)
15 in
(38 cm)
3 in
(7.6 cm)
NOTE: GTO receiver (RB709U),
batteries (12vdc, U1, 230A minimum)
not included. Must order separately.
Owner’s Manual
GTO/PRO GP-SW050
AC Powered Swing Gate Operators
WARNING
Gate Bracket
Gate Warning Signs
(one for each side)
Owner’s Manual
Reducer /Operator Arm
HARDWARE BAG - R4027
1/2" Nut (2)
Clevis Pin (1)
1/2" Washer (2)
Plastic Spacer (1)
Hairpin Clip (1)
½" – 2¾" Bolt (2)
8
Download from Www.Somanuals.com. All Manuals Search And Download.
installing the gate operator
This unit must only be installed by an experienced technician.
Preparation of the Gate
Before installing the GTO swing gate operator, make sure:
• the gate is properly installed.
• the gate is plumb, level, and moves freely.
• the gate does not bind or drag on the ground.
Overview of a Single Gate Operator Installation
The diagram below is an example of a single swing gate installation with required safety features. The
operator must be installed on the inside of the gate. You must install safety edges and photo beams
(not included) to reduce the possibility of bodily injury.
NOTE: A separate gate or entrance must be installed for pedestrian use.
Safety Edge
Safety Edge
Receiver
Warning Sign
Operator
Use PVC conduit
for Receiver wire
AC POWER
Photo Beams
Photo Beams
Safety Edge
Use rigid conduit
for inbound AC wire.
Photo Beam
Photo Beam
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Using the Mounting template
The mounting template (see insert) is designed to simplify mounting the operator. It provides the installer with
the proper locations for running power and accessory wiring conduits. The template is also marked with the
correct distance between the operator mounting holes and shows the installer how to position the operator for
the correct clearance between the housing and the gate.
NOTE: The operator must be securely mounted on a level concrete pad. If you do not have an existing pad to work
3
with, be sure to install wiring conduit before pouring concrete. You must use (5) /8” diameter wedge type mounting
anchors, washers, and nuts (not included) to mount the operator on the pad.
Study the mounting template. Lay the mounting template on the level concrete pad and mark the pad according
to the instructions on the template.
Before mounting the operator, check the following:
•
•
•
The concrete pad is level.
(6) 3/8”diameter mounting anchors are in their correct positions.
Conduit for power and accessory wiring is installed.
Mounting Operator
Concrete mounting pad 16 in x 16 in. Consult local building codes for depth below
ground level. Absolute minimum depth 30 in (76.2 cm) below ground level.
Use 3/8 in (.95 cm) diameter concrete mounting bolts in mounting pad.
6 Concrete
Mounting Bolts
3/8” diameter
not included
33 in
(83.8cm)
TO BASE
16 in
(45.7cm)
16 in
(45.7 cm)
G
R
O
U
N
D
L
E
3
V
E
L
6
/
in
8
(16.2 cm)
10 in
(25.4 cm)
5
4
/
8
in
(16.2 cm)
30 in
(76.2 cm)
MINIMUM
BELOW GROUND LEVEL
10
Download from Www.Somanuals.com. All Manuals Search And Download.
Mounting template
(NOT TO SCALE)
11
Download from Www.Somanuals.com. All Manuals Search And Download.
removing the operator Housing
Before you can gain access to the operator frame and its mounting holes, the housing will have to be
removed from the operator.
1.
2.
Remove the (2) 3/8”allen bolts and (2) m8 washers from the operator housing (this hardware is
located on each side of the housing).
Lift the housing off the operator and set it aside.
Allen Bolts
with 5mm key
Washers
Mounting the operator
1.
2.
Lift the operator and align its mounting holes over the 3/8”diameter concrete mounting anchors.
Lower the operator into position and fasten it to the mounting anchors with (4) 3/8”washers and
nuts (not provided).
12
Download from Www.Somanuals.com. All Manuals Search And Download.
connecting Power to the operator
1.
Turn the breaker power switch off before connecting AC power. Have a licensed electrician
run 115 Vac wiring into the Field Wiring Connection Compartment. The 115 Vac line will power
the gate operator system. The circuit must be protected with a 15 A main disconnect breaker
(not provided).
NOTE: Power and wiring connections MUST be
performed by a licensed electrician in accordance
with NEC (National Electric Code) and local codes.
NEVER run low voltage (e.g., accessory or receiver)
wires in conduit containing 115 Vac wiring.
2.
3.
Connect batteries to operator as shown. The red wire connects to the positive terminal
in the control box. The black wire connects to the negative terminal in the control
box. The jumper wire (included) connects both batteries together with the remaining
terminals. Wire the 24V system in series as shown below.
Turn on AC power at this time.
RED WIRE to positive (+)
JUMPER WIRE (Supplied)
negative (-) to positive (+)
NOTE: Battery should be a 12 Vdc, U1,
230 Amp Minimum, Lead Acid Battery
(Typical Lawn and Tractor Battery).
BLACK WIRE to negative (–)
NOTE: When first turning operator power switch on, the unit may beep once
every 5 seconds until the new batteries can be fully charged (30-60 minutes charging time).
13
Download from Www.Somanuals.com. All Manuals Search And Download.
gate arm connection overview
Right Mounted Arm
Center point of gate hinge
to center of gate bracket pin
(approximately) 50”
Center point
of gate hinge
Column
Closed Gate
Range of
Arm Movement
160°-175°
5°-10°
Housing
Pivot point
of operator
Opened Gate
CAUTION:
DO NOT STAND
IN THIS AREA
IMPORTANT: Be sure the operator housing
will not be hit by a fully open gate and that
the gate column will not interfere when
housing is installed.
NOTE: All work on operator requires disconnecting AC power and batteries !
14
Download from Www.Somanuals.com. All Manuals Search And Download.
connecting the gate arm to the gate
Key
Bolts
and
Washers
Reducer
Arm
Output Shaft
Fig. 1
Fig. 2
1. Install the key into the output shaft. (Fig. 1)
2. Fit the end of the reducer arm onto the output shaft as shown and
tighten the bolts. (Fig. 2)
3. Turn the power on.
4. Set DIP switch 1 to designate the operator arm as left or right (Fig. 3)
(right is shown here).
OPTIONS
OFF
ON
MODE 1
MODE 2
OFF
ON
<<<
DELAY
MASTER
SAFE
>>>
SIMUL
SLAVE
SECURE
OPEN DIR.
SLV OPN
DUAL MODE
LOW BATT
5. Manually move gate to the closed position. (Fig. 4)
Fig. 3
Gate Bracket
Closed Gate
Operator Arm
(approx)
Reducer Arm
5°-10° Angle
Clevis Pin
Fig. 4
Hairpin Clip
Closing
CAUTION:
DO NOT STAND
IN THIS AREA
Fig. 5
6. Unfold the arm to approximately a 5-10° angle. (Fig. 4)
7. Use ‘CLOSE’ button on control board to move operator arm/reducer arm to the gate. CAUTION: Be careful
not to stand in the gray area surrounding the operator. (Fig. 4) Be prepared to stop (using the ‘STOP’ button)
when the gate arm and reducer arm near the desired position.
NOTE: Use ‘JOG’ buttons to fine tune the position.
8. Mark the position of the gate bracket holes on the gate, drill holes and mount bracket.
9. Fit the end of the operator arm into the gate bracket and attach using clevis pin and hairpin clip. (Fig. 5)
NOTE: Gate Arm’s length can be adjusted
by rotating the gate arm’s tube before
Fig. 6
mounting it to the gate bracket. (Fig. 5)
15
Download from Www.Somanuals.com. All Manuals Search And Download.
control Board Description
2
1
BLDC SPEED CONTROL
EXIT
SHADOW SAFETY
LIMIT SENSORS
ALARM
GTO LOOP DETECTORS
3
STATUS
AT OPEN
LIMIT
PRISON
MODE
+12Vdc
COM
+ ACC. PWR.
12VDC
4
5
- 300ma
DUAL LINK
LINK COM
DUAL
LINK
14
LOCK
20
LOCK N.C.
LOCK COM
LOCK N.O.
RUN 1
13
12
11
6
RUNNING
CLOSED
DIAG.
PORT
7
8
RUN 2
OPTIONS
CLOSED 1
CLOSED 2
OFF
ON
MODE 1
MODE 2
19
OFF
ON
<<<
DELAY
MASTER
SAFE
>>>
SIMUL
SLAVE
SECURE
OPEN DIR.
SLV OPN
DUAL MODE
LOW BATT
10
CYCLE
CYCLE
STALL FORCE ADJUST
AUTO CLOSE
TIMER
SAFETY
SAFETY
<<<
>>>
SHADOW
LOOP
SHADOW
18
OPEN
EDGE
OPEN EDGE
CLOSE EDGE
OPEN
17
CLOSE
EDGE
MIN
MAX
MIN
MAX
OFF
120
OPEN
CLOSE
STOP
W1
9
LIMIT ADJUSTMENTS
SET
LIMIT
CLOSE
<<<
JOG
>>>
16
STOP
COM
COM
COM
CUT TO USE 21
3 BUTTON
TEST SWITCHES
STATION
COM
CLOSE
STOP
OPEN
COM
15
COM
GTO Inc. Tallahassee, FL
SX4000 Logic Board Rev. E
12
1
2
BLDC Motor Control Connection
Limit Sensor Connection
LED Indicator - To Show‘Running’Relay is on
LED Indicator - To Show‘Lock’Relay is on
LED Indicators - To Show Dual Link Communication
Test Switches - To Control Gate Operation
Limit Adjustment Control Switches
13
14
15
16
17
18
19
20
21
3
Alarm / Buzzer Connection
4
12Vdc Accessory Power
5
Dual Link Connection
6
Relay Output - To Control Lock
Relay Output - To Indicate Gate’s Running
Relay Output - To Indicate Gate’s Closed
Accessory Inputs
Left and Right Stall Force Adjustment
7
Auto Close Timers Adjustment Potentiometer (OFF, 3-120 sec)
DIP Switch Option Setting
8
9
Diagnostic Port (NOT for telephone)
10
11
LED Indicators - For accessory inputs
LED Indicators - To show‘closed’relay is on
W1- for 3-button Station with Normally Close‘Stop’Button
16
Download from Www.Somanuals.com. All Manuals Search And Download.
setting the limits
CAUTION: Be extremely careful not to stand in the path of the gate arm while setting limits.
OPEN LIMIT SETTING:
1. Turn on operator power.
2. Press and release the OPEN button on the board and be prepared to press the STOP button
when the gate reached the desired open position/limit.
3. The JOG buttons can be used to bring the gate to the precise open position. The JOG buttons
will slowly run the gate when pressed and stop the gate when released.
4. Once at the desired open position, press and hold the SET LIMIT button for 3 seconds or until
the alarm sounds and STATUS LED is on. At this time, release the SET LIMIT button.
5. Be prepared to stop the gate when it reaches the closed position.
CLOSED LIMIT SETTING:
1. If not already closed, press and release the close button.
2. Press and release the CLOSE button on the board and be prepared to press the STOP button
when the gate reached the desired closed position/limit.
3. The JOG buttons can be used to bring the gate to the precise closed position. The JOG buttons
will slowly run the gate when pressed and stop the gate when released.
4. Once at the desired closed position, press and hold the SET LIMIT button for 3 seconds or until
the alarm sounds and STATUS LED is on. At this time, release the SET LIMIT button.
5. Open the gate to allow it to stop on its own.
6. Open and close the gate to verify proper operations. If limits are not set
properly, redo limit setting steps above.
NOTE: If limits are too short, use jog button to move arm short distances to stop gate at
the precise open or closed positiCoLnOS.E
RUN 2
EDGE
OPEN
CLOSE
OPEN
SET
LIMIT
17
Download from Www.Somanuals.com. All Manuals Search And Download.
stall Force and auto-close adjustments
Stall Force Adjustment:
IMPORTANT: For safety reasons, the STALL FORCE potentiometers are set at the “10 o’clock” position
at the factory.
The obstruction sensitivity is independently adjustable for each direction of travel. Upon sensing an
obstruction, the gate will stop and reverse direction for approximately 2 seconds.
1. Turning the potentiometer clockwise (toward the MAX position) increases the amount of force
the operator applies to an obstruction. Turning the potentiometer counter-clockwise (toward the
MIN position) decreases the amount of force the operator applies to an obstruction.
2. Use a small screwdriver to adjust the appropriate potentiometer and operate the gate until it can
run without obstructing and reversing direction.
LOCK N.O.
RUNNING
RUN 1
RUN 2
LED10
CLOSED
CL
OFF
LED09
OFF
<<<
DELAY
MA
STALL FORCE ADJUST
AUTO CLOSE
TIMER
<<<
>>>
MIN
MAX
MIN
MAX
OFF
120
Auto-Close Adjustment:
The Auto-Close potentiometer allows the user to set the time that the gate will stay at the open
position/limit before it automatically starts to close the gate.
This feature can be turned off by turning the AUTO CLOSE TIMER potentiometer all the way
counter- clockwise. It is shipped from the factory in the OFF position (auto close feature is disabled).
•
•
•
•
The auto close time is adjustable from 3-120 seconds.
This feature is only enabled when the gate is at the open limit.
This feature is disabled if the following inputs are activated.
OPEN, SAFETY, SHADOW, CLS-EDGE or STOP.
18
Download from Www.Somanuals.com. All Manuals Search And Download.
DiP switch settings
MODE 1 & MODE 2:
•
Reserved for future features
DIP #1: OPEN DIRECTION
•
•
OFF: for gate that opens to the left, closes to the right.
ON: for gate that opens to the right, closes to the left.
DIP #2: SLAVE OPEN SEQUENCE (dual gate installation only)
•
NOTE: This DIP switch is applicable if and only if all the
following conditions are valid:
•
•
•
DIP switch #3 is OFF (Master mode)
Dual Link cable is connected.
Slave mode is detected from the second board (DIP switch #3
of the second board is ON)
•
If the above conditions are not met, the board will default to
single gate operation. If DIP #3 is OFF (Master)
OFF: Slave gate will open after the master gate.
ON: Slave gate will open simultaneously with the master gate.
•
•
DIP #3: MASTER/SLAVE (applicable to dual gate installation only)
•
NOTE: This DIP switch is applicable if and only if all the
following conditions are valid:
•
•
•
Dual Link cable is connected.
The second operator is detected by the master.
If the above conditions are not met, the board will default to
single mode operation. If DIP #3 is OFF (Master)
OFF: Master mode operation in dual gate installation if slave
setting is detected from the other board.
ON: Slave mode operation in dual gate installation if master
setting is detected from the other board. Control board is non-
functional if master operator is not detected.
•
•
DIP #4: FAIL SAFE/FAIL SECURE OPERATION
•
•
OFF: Fail safe mode
When low battery and no AC power conditions are detected
the gate will automatically run to the opened position. The
gate will remain at the open position until AC power is restored
and the battery reaches an acceptable charge level.
ON: Fail secure mode
These switches are for dual gate
applications only. See page 26 for
dual gate settings.
When low battery is detected and no AC power is present, the
gate will automatically run to the closed position. Gate will
auto close only if auto close feature is enabled and gate is at
RUN 1
LED10
PORT
open limit. The gate will remain at the closed position until AC
power is restored and the battery reaches an
acceptable chargeRlUeN 2vel.
CLOSED
CLOS
OFF
ON
LED09
OFF
ON
<<<
DELAY
MASTER
SAFE
>>>
SIMUL
SLAVE
SECURE
STALL FORCE ADJUST
19
Download from Www.Somanuals.com. All Manuals Search And Download.
input connections
NOTE:
• All control inputs are dry-contact, normally open, inputs except for #8. DO NOT apply external voltage
sources to these inputs.
• All inputs are connected with respect to COMMON terminal.
• All inputs have a corresponding LED indicator for diagnostic purposes. All input LED indicators, except for the
STOP LED, will be dimly lit when its corresponding input is inactive and brightly lit when it is activated.
1
2
CYCLE: (Typically for use with doorbell button or hardwired key pad)
• Each activation at this input will cycle the operation as follows:
….→ OPEN → STOP → CLOSE → STOP → OPEN → …
SAFETY: (Typically for use with photo beam device, loop detector
or other non-contact sensors)
• Activation of this input while the gate is closing will cause the gate to
stop and return to the opened position.
• Activation of this input while the gate is opening has no effect (gate
will continue to open).
• Activation of this input while gate is idle will prevent gate from closing.
CYCLE
1
2
3
4
5
6
7
8
9
SAFETY
SHADOW
LOOP
OPEN EDGE
CLOSE EDGE
OPEN
3
4
5
SHADOW: (Typically for use with loop detector device)
• This input is only monitored when the gate is at the fully open
position. At any other position, activation of this input has no effect on
gate operation.
• Activation of this input while gate at the fully open position will
prevent gate from closing.
CLOSE
STOP
OPEN EDGE: (Typically for use with safety edge device)
• Activation of this input while the gate is opening will cause the gate to
stop and reverse direction for approximately 2 seconds.
• Activation of this input while the gate is closing has no effect (gate
will continue to close).
COM
COM
COM
• Activation of this input while gate is idle will prevent gate from opening.
CLOSE EDGE: (Typically for use with safety edge device)
• Activation of this input while the gate is closing will cause the gate to
stop and reverse direction for approximately 2 seconds.
• Activation of this input while the gate is opening has no effect (gate will continue to open).
• Activation of this input while gate is idle will prevent gate from closing.
6
7
8
OPEN: (Typically for use with exit loop or wand)
• Activation of this input will open the gate if it’s not already at the open position
• Activation of this input while at open limit will restart the auto close time (if enabled).
CLOSE: (Typically for use with 3-button control station)
• Activation of this input will close the gate if it is idle AND not already at the closed position.
• Activation of this input while gate is opening will stop the gate.
STOP: (For use with 3-button control station that has‘NORMALLY CLOSED’STOP button)
• Activation of this input will stop the gate.
• Jumper‘W1’must be cut when using normally closed‘STOP’button.
• A normally closed button must be connected to‘STOP’and‘COM’in order for gate to operate.
9
COM: Circuit common (reference for all accessory inputs)
• Three (3) terminals to provide extra common connection point.
20
Download from Www.Somanuals.com. All Manuals Search And Download.
accessory terminal connections
1
2
3
4
5
6
7 9
8
10 11
12 13 14 15 16 17 18 19 20 21 22
ACC. POWER
DUAL CABLE
RELAY OUTPUTS
12v power supply can be used
for loop detectors, receivers,
photo beams, keypads and
other accessories.
1
2
22
13
OPEN
CLOSE
STOP
17
20
NO
COM
NC
18
19
V
V
+
–
LOOP
LOOP
GTO Loop Detector
3 Button Station
SOS
LOOP
17
20
13
20
Siren-Activated
Entry Device
GTO Photo Beams
20
12
20
17
GTO Universal Receiver
Refer to Universal Receiver manual
for additional connections
GTO Exit Wand
Refer to Exit Wand manual
for additional connections
20
15 16
Edge Sensor
2
3
1
ABC
DEF
5
6
4
JKL
MNO
GHI
8
9
7
TUV
WXY
PRS
21
12
0
NOTE: Connections are for typical
applications. There may be additional
connection options for applications that
are not illustrated here.
GTO Keypad
21
Download from Www.Somanuals.com. All Manuals Search And Download.
output connections
Note:
RUNNIN
CLOSED
• Maximum rating for all relay outputs are 24Vac/dc, 1 Amp.
• All relay outputs are dry contact (no voltage) switching.
• All outputs have corresponding LED indicator for diagnostic purposes.
The corresponding LED indicator will be lit when its relay is activated.
RUN 1
RUN 2
CLOSED 1
CLOSED 2
1. CLOSED 1 and CLOSED 2: At closed limit relay output.
• These two (2) terminals are shorted when gate is at the closed limit.
2. RUN 1 and RUN 2: Gate moving relay output.
• These two (2) terminals are shorted whenever the gate is moving/running.
3. LOCK COM and LOCK N.O. / LOCK N.C.: Lock relay output
• This relay output is designed for use with either mechanical or mag-lock device. The relay is
activated (releasing the lock) during the first and the last 2-4 seconds of gate running.
Example A: Mag-Lock Connection: Use LOCK COM and LOCK NC terminals. The diagram below is for a
typical mag-lock connection. Refer to the mag-lock manual for detailed operations.
Example B: For locks that are energized to release: Use LOCK COM and LOCK NO terminals.
LOCK N.C.
LOCK
LED11
Example A
LOCK COM
LOCK N.O.
RUNNING
Mag Lock
24vDC Max, 1 Amp Max
To positive (+) terminal of
mag-lock power supply
To negative (-) terminal of
mag-lock power supply
LOCK N.C.
LOCK
LED11
Example B
LOCK COM
LOCK N.O.
RUNNING
Lock Coil or Controller
24vDC Max, 1Amp Max
To positive (+) terminal of
Lock power supply
To negative (-) terminal of
Lock power supply
22
Download from Www.Somanuals.com. All Manuals Search And Download.
accessory Power supply connection
•
•
12Vdc @ 300 mA (.3A) maximum power supply for additional accessories.
If you lose power to your accessories, the accessories are protected by a poly-fuse. Disconnect
accessories and allow poly-fuse to cool down for 2 minutes before reconnecting.
STATUS
AT OPEN
12Vdc @
300 mA
Power Supply
+12Vdc
COM
LIMIT
+ ACC. PWR.
12VDC
PRISON
MODE
- 300ma
DUAL LINK
LINK COM
DUAL
LINK
23
Download from Www.Somanuals.com. All Manuals Search And Download.
Prison Mode operation
(class iV aPPlicatioNs)
Prison mode operation means that constant pressure at the CLOSE or the OPEN push button station
input is required to move the gate in the desired direction.
Follow these steps to toggle the PRISON MODE operation on/off:
1.
2.
3.
4.
Power down the unit.
Press and hold the OPEN and CLOSE push button while powering on the unit.
The PRISON MODE LED indicator will be on if operating in prison mode.
Repeat the above steps to turn off prison mode operation.
AX
MIN
MAX
OFF
STOP
W1
CUT TO USE
3 BUTTON
STATION
CLOSE
OPEN
Press and hold at power up to toggle
to prison mode.
W1
CUT TO USE
3 BUTTON
STATION
CYCLE
SAFETY
SHADOW
LOOP
Wiring a 3-button station
OPEN EDGE
CLOSE EDGE
OPEN
NOTE: The W1 Jumper must be cut in order
to use a 3-button station.
OPEN
To restore normal operation of cut jumper
you must connect a wire between the
CLOSE
CLOSE
STOP and COM terminals (or you could use
STOP
a normally closed push-button). This wire
functions the same as the W1 jumper.
STOP
COM
COM
COM
24
Download from Www.Somanuals.com. All Manuals Search And Download.
reinstalling the operator Housing
Check to make sure the safety edges, photoelectric beams, warning signs, and pedestrian gate (if necessary) are
installed (see pages 5-6) before fastening the housing to the operator.
1.
Lower the operator housing into
position over the operator.
2.
Pull sides out slightly so that the
housing sits into place properly over the base.
3.
Fastenthehousingtotheoperatorwith
(2) Washers and (2) Allen Bolts.
Allen Bolts
with 5mm key
Washers
The installation is complete. Test the operator, accessories, and safety devices for correct function. Read and
fill out the INSTALLATION CHECKLIST on the back cover of this manual.
25
Download from Www.Somanuals.com. All Manuals Search And Download.
installing a Dual gate operator system
IMPORTANT: With a dual gate system certain control board settings and connections are required on the MASTER
unit only and some are required on both the MASTER and the SLAVE unit. The list below gives an overview.
•
•
•
•
•
•
Gate Sequencing - DIP #2 on Master Unit
Alarms - wired to MASTER only
Entry Devices - can be wired to either unit
Adjustable Auto Close - MASTER controls opening and closing for both gates)
Locks - controlled by the MASTER unit
Setting Limits - set DIP#3 on each operator to MASTER position (OFF) in order to set the limit for each
gate. After the limit is set, DIP #3 can be set to SLAVE (ON) position for dual mode operation.
Dual gate link connection
•
These two (2) terminals provide communication connections for dual gate applications where one
unit operates as a master and the other as slave operator.
•
Shielded twisted pair must be used. The shield (drain wire) connection should be connected at
Master Unit Only to the LINK COM terminal but not both.
•
•
•
•
Connect the DUAL LINK terminals of the two operators together.
Connect the LINK COM terminals of the two operators together.
Set OPTIONS DIP Switch #2 and #3 accordingly.
If these terminals are not connected, each operator will automatically operate in single mode, if
DIP #3 is in MASTER position (OFF). If DIP #3 is set to the SLAVE position (ON) the unit is
non-functional.
•
Recommended Belden Wire®, 22 AWG, type 8761, 9461, 9451, 1266A or equivalent.
1-pair shielded with drain wire. Available at your local electrical supply store.
ALARM
STATUS
AT OPEN
+12Vdc
LIMIT
+ ACC. PWR.
PRISON
12VDC
MODE
COM
- 300ma
ALARM
DUAL LINK
DUAL
LINK
STATUS
LINK COM
AT OPEN
LIMIT
PRISON
MODE
+12Vdc
COM
+ ACC. PWR.
12VDC
- 300ma
DUAL LINK
LINK COM
DUAL
LINK
Drain wire connects
at MASTER unit only.
NOTE: Do not combine AC and low voltage
wire in the same conduit.
26
Download from Www.Somanuals.com. All Manuals Search And Download.
setting Dual gate sequence
GP-SW050operatorscomefromthefactorywiththe#2DIPswitchessettoOFF. DIPSwitchesmustbechangedto
accommodate dual gate operation. The information below shows the proper settings for a dual gate application.
OFF
OFF
ON
ON
OFF
OFF
ON
ON
<<<
DELAY
MASTER
SAFE
<<<
DELAY
MASTER
SAFE
>>>
SIMUL
SLAVE
SECURE
>>>
SIMUL
SLAVE
SECURE
STALL FORCE ADJUST
STALL FORCE ADJUST
Master DIP Switch
Slave DIP Switch
Settings
Settings
IMPORTANT: The #2 Switch Settings are set on the MASTER Operator only.
If DIP #3 is set to slave (ON), DIP #2 and #4 are dictated by MASTER DIP settings.
DIP #1
OFF: For gate that opens to the left, closes to the right.
ON:
For gate that opens to the right, closes to the left.
DIP #2
ON:
SLAVE and MASTER open simultaneously
OFF: MASTER opens 1st, SLAVE delays when opening
DIP #3
ON:
OFF: MASTER mode used for MASTER operator only
SLAVE mode used for SLAVE operator only
DIP #4
ON:
OFF: FAIL SAFE mode
FAIL SECURE mode
27
Download from Www.Somanuals.com. All Manuals Search And Download.
28
Download from Www.Somanuals.com. All Manuals Search And Download.
Maintenance
WarNiNg: alWaYs tUrN oPerator oFF aND DiscoNNect
ac PoWer BeFore aDJUstiNg or serViciNg it.
Maintenance schedule:
• Test the operator, accessories, and safety devices monthly.
• Service the gate operator, accessories, and safety devices regularly.
Maintenance checklist
• Test the safety edges to make sure the gate responds.
• Check the obstruction settings (both open and close modes) see page 18.
• Check for wear on all moving parts, and tighten bolts as necessary.
• Check the gearbox for any sign of oil leakage. If the gearbox is leaking,
call the GTO Service Department for assistance.
• Check hinges on the gate and lubricate if needed.
• Check for loose or corroded wires.
• Make sure the warning signs (see page 5) are installed.
29
Download from Www.Somanuals.com. All Manuals Search And Download.
troubleshooting guide
WarNiNg: alWaYs tUrN oPerator oFF aND DiscoNNect
Batteries BeFore aDJUstiNg or serViciNg it.
gP-sW050 audible Feedback
s Y M P t o M
D i a g N o s i s
c H e c k
One beep every 5 seconds There is no AC power present.
when the gate is in motion.
•
•
•
GFI
Circuit Breaker
Connections in the Field Wiring
Connection Compartment
The battery voltage is low.
•
•
•
Battery Connections
Battery Voltage
Load Test Battery
One beep every 10 seconds The battery is critically low.
when the gate is idle.
•
•
•
GFI
Circuit Breaker
Connections in the Field Wiring
Connection Compartment
If #4 dip switch is in the FAIL SAFE
position and the gate is at the OPEN
Limit, the operator will be disabled until • Battery Connections
AC power is restored and the battery
voltage has reached 26 vdc.
•
•
Battery Voltage
Load Test Battery
If #4 dip switch is in the FAIL SECURE
position and the gate at the CLOSED
Limit, the operator will be disabled until
AC power is restored and the battery
voltage has reached 26 vdc.
1 beep with 2 seconds
pause
The revolution counter circuit board is
not being detected.
•
•
Check Connections for Limit
Sensors on Logic Board
2 beeps with 2 seconds
pause
The logic board does not detect the
motor drive board connections.
Check BLDC Speed Control
connections on Logic Board and
Motor Drive Board
3 beeps with 2 seconds
pause
The gate has traveled outside the
maximum allowable limit of the
operator.
•
•
Check Limit Sensor Connections
on Logic Board
4 beeps with 2 seconds
pause
The motor has moved in the wrong
direction.
Check BLDC Speed Control
connections on Logic Board and
Motor Drive Board
5 beeps with 2 seconds
pause
No movement was detected from the
motor twice.
•
•
Check path of Gate for
obstructions.
Check to ensure motor is not
jammed.
30
Download from Www.Somanuals.com. All Manuals Search And Download.
gP-sW050 Visual Feedback
s Y M P t o M
D i a g N o s i s
c H e c k
Cycle LED ON brightly
Status Light flashes
Cycle terminal shorted to Com
•
Push button or key on keypad is
stuck.
•
Wire between push button,
keypad, etc. and cycle terminal is
shorted
•
Check terminal voltage with
respect to Com to ensure you
read 12 vdc.
Safety LED ON
brightly Status Light
flashes
Safety terminal shorted to Com
•
•
•
Photo beam or loop detector is
sensing a presence.
Relay on photo beam or loop
detector is shorted or latched.
Wire between photo beam
or loop detector and safety
terminal is shorted.
•
Check terminal voltage with
respect to Com to ensure you
read 12 vdc.
Shadow LED ON
brightly Status Light
flashes
Shadow terminal shorted to Com
•
•
•
Photo beam or loop detector is
sensing a presence.
Relay on photo beam or loop
detector is shorted or latched.
Wire between photo beam or
loop detector and shadow
terminal is shorted.
•
Check terminal voltage with
respect to Com to ensure you
read 12 vdc.
Open Edge LED ON
brightly Status Light
flashes
Open Edge terminal shorted to Com
•
•
•
•
Edge sensor is sensing an
obstruction.
Relay from edge sensor is
shorted or latched.
Wire between edge sensor and
open edge terminal is shorted.
Check terminal voltage with
respect to Com to ensure you
read 12 vdc.
31
Download from Www.Somanuals.com. All Manuals Search And Download.
s Y M P t o M
D i a g N o s i s
c H e c k
Close Edge LED ON
brightly Status Light
flashes
Close Edge terminal shorted to
Com
•
•
•
•
Edge sensor is sensing an
obstruction.
Relay from edge sensor is
shorted or latched.
Wire between edge sensor and
open edge terminal is shorted.
Check terminal voltage with
respect to Com to ensure you
read 12 vdc.
Open LED ON brightly
Status Light flashes
Open terminal shorted to Com
•
•
Push button is stuck.
Exit wand, Loop detector,
Photo beam, etc., is sensing a
presence.
•
•
•
Relay from Exit wand, Loop
detector, Photo beam, etc. is
shorted or latched.
Wire from Exit wand, Loop
detector, Photo beam, etc. is
shorted.
Check terminal voltage with
respect to Com to ensure you
read 12 vdc.
Close LED ON brightly
Status Light flashes
Close terminal shorted to Com
Stop and Com terminals open.
•
•
Push button is stuck
Check terminal voltage with
respect to Com to ensure you
read 12 vdc.
Stop LED ON brightly
Status Light flashes
•
•
W1 is cut and normally open
button is wired to Stop and Com.
W1 is cut and no normally
closed push button is wired to
Stop and Com.
•
•
Wire between normally closed
push button and Stop terminal is
cut or disconnected.
Check terminal voltage with
respect to Com to ensure you
read 0 vdc.
32
Download from Www.Somanuals.com. All Manuals Search And Download.
Warranty and repair service
If the GTO gate operator system is not working properly, please follow the steps below:
Instructions for the Consumer/End User:
1.
2.
Call your dealer or installer for service. Only an experienced technician may service this unit.
If your dealer or installer is unable to solve the problem, he will contact the GTO Service Department.
Instructions for the Dealer/Installer:
1.
2.
3.
Call the GTO Service Department at (800) 543-1236 or (850) 575-4144 to discuss the problem with a service technician.
If repair or replacement is necessary, you will be assigned a Return Goods Authorization Number (RGA).
Carefully pack the component(s) authorized for return and write the RGA number on the outside of the package in LARGE BOLD
PRINT. Ship freight prepaid to GTO, Inc., 3121 Hartsfield Road, Tallahassee, FL 32303. NOTE: GTO products shipped without a
Return Goods Authorization Number (RGA) or shipped freight collect will not be accepted at the factory.
Remember all returns must include a copy of receipt.
4.
If GTO, Inc. determines that the warranty covers the repair or replacement of your gate operator:
GTO will pay shipping costs (equivalent to United Parcel Service ground rate) for return to owner of items repaired under warranty.
GTO Hours of Operation: Mon. – Fri., 8:00 A.M. - 7:00 P.M. (ET)
Phone (800) 543-1236 • FAX (850) 575-8950
GTO AC Powered Gate Operator Limited Warranty
GTO AC powered gate operators are warranted by the manufacturer against defects in materials and manufacturer workmanship for
a specific period of time beginning from the date of purchase, provided recommended installation procedures have been followed.
Thewarrantyperiodforresidentialinstallationsisseven(7)yearsformechanicalparts;five(5)yearsforelectroniccomponents.
The warranty period for commercial installations is three (5) years for mechanical parts; three (3) years for electronic
components.
In the case of product failure due to defective material or manufacturer workmanship within the warranty period, the operator will be
repaired or replaced (at manufacturer’s option) at no charge to the customer, if returned freight prepaid to GTO, Inc., 3121 Hartsfield
Road, Tallahassee, Florida 32303. IMPORTANT: Call (850) 575-0176 or Fax (850) 575-8950 for a Return Goods Authorization
(RGA) number before returning to factory. Products received at the factory without an RGA number will not be accepted.
Replacement or repaired parts are covered by this warranty for the remainder of the warranty period or six (6) months, whichever
is greater. GTO will pay shipping charges (equivalent to United Parcel Service ground rate) for return to owner of items repaired
under warranty.
The manufacturer will not be responsible for any charges or damages incurred in the removal of the defective parts for repair, or
for the reinstallation of those parts after repair. This warranty shall be considered void if damage to the product(s) was the result of
improper installation or use, tampering, connection to an improper power source, or if damage was caused by lightning, wind, fire,
flood, insects or other natural agent. This warranty gives you specific legal rights, and you may also have other rights which may
vary from state to state. This warranty is issued in lieu of all other warranties, expressed or implied. NOTE: Verification of the
warranty period requires copies of receipts or other proof of purchase. Please retain these records.
After the warranty period, GTO or one of its authorized service centers will make any necessary repairs for a nominal fee. Call GTO
at (850) 575-0176 for more information.
GTO MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEVER, EXPRESSED OR
IMPLIED, AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS
FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED.
LIMITATION OF LIABILITY
The remedies of purchaser set forth herein are exclusive and the total liability of GTO with respect to this order, whether based on
contract, warranty, negligence, indemnification, strict liability or otherwise, shall not exceed the purchase price of the component
upon which liability is based. In no event shall GTO be liable for consequential, incidental or special damages.
Download from Www.Somanuals.com. All Manuals Search And Download.
installation checklist
The installation of this operator conforms to CLASS __________.
The installer verifies that (each item must be checked):
____ Required safety edges or photo beams were installed.
____ Customer was informed that this gate is for vehicular use ONLY. Pedestrians MAY NOT use this gate.
____ A separate gate or entrance was installed for pedestrian use.
____ All warning signs and labels were installed as specified in the IMPORTANT SAFETY INSTRUCTIONS.
____ Safety instructions were reviewed with the customer.
____ The IMPORTANT SAFETY INSTRUCTIONS manual was given to the customer.
____ Customer was asked to fill out customer support card and mail it to GTO, Inc.
____ Customer was asked to retain all receipts (receipts provide proof of warranty).
____ Customer was asked to retain IMPORTANT SAFETY INSTRUCTIONS, etc. for future reference.
____ The completed installation was photographed from both the front and back of the gate. Photo was dated.
Customer’s Signature
Date
Date
Installer’s Signature
© 2008 GTO, Inc.