Goodman Mfg Furnace SS GME8 User Manual

GME8 SEriES  
Multi-Position, Dual$aver  
Multi-sPeeD Gas Furnace  
80% AFUE  
HeatinG inPut: 70,000–115,000 Btu/H  
Standard Features  
• Dual-diameter tubular heat exchanger  
• Two-stage gas valve that allows installer to  
turn on two-stage operation with the flip  
of a dipswitch  
• Energy-efficient circulator motor (EEM)  
• 115V Silicon Nitride igniter designed for long igniter life  
• Furnace control board with self-diagnostics, color-cod-  
ed low-voltage terminals, and provisions for electronic  
air cleaner and 24-volt humidifiers  
• Control board stores the last five diagnostic codes in  
memory; simple push-button activation outputs the  
fault history to a flashing red LED  
• Low constant fan allows homeowner to activate the  
low heat speed to efficiently circulate air throughout  
the home.  
• Self-adjusting feature automatically adjusts furnace to  
high- or low-stage operation based on outside tem-  
perature without an outdoor temperature sensor  
All models comply with California NOx emissions standards  
Cabinet Features  
• Fully insulated, heavy-gauge steel cabinet with durable  
baked-enamel finish  
• Foil-faced insulation lines the heat exchanger  
• Designed for multi-position installation: upflow,  
horizontal left or right  
Removable bottom for side- or bottom-return applications  
• Convenient left or right connection for gas/  
electric service  
Contents  
Nomenclature ................................................................................................... 2  
Product Specifications ................................................................................. 3  
Dimensions ......................................................................................................... 4  
Airflow Data ....................................................................................................... 5  
Wiring Diagrams .............................................................................................. 6  
Accessories ......................................................................................................... 8  
• Top gas connection on most models  
• Coil and furnace fit flush for most installations  
*
Exchanger Limited Warranty (good for as long as you own your home), 10-Year Unit Replacement Limited Warranty and  
10-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is  
not required in California or Québec.  
SS-GME8  
11/10  
Supersedes 3/10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ProDuct sPeciFications  
sPeciFications  
GME8  
0703BXC*  
GME8  
0905CXC*  
GME8  
1155CXC*  
Performance Data  
Input¹  
70,000  
56,000  
48,000  
80  
90,000  
72,000  
64,000  
80  
115,000  
92,000  
80,000  
80  
Output¹  
LP Output¹  
AFUE²  
Tons AC @ 0.5” ESP  
Temperature Rise Range (°F)  
Circulator Blower  
Size (D x W)  
3
5
5
20 - 50  
35 - 65  
35 - 65  
10 X 8  
1/2  
4
10 X 10  
10 X 10  
HP  
1
4
1
4
Speed  
Vent Diameter³  
No. of Burners  
Disposable Filter (in²)  
Electrical Data  
Min. Circuit Ampacity⁴  
Max. Overcurrent Protecꢀon⁵  
Ship Weight (lbs)  
4
4
4
3
4
5
290  
480  
480  
8.2  
15  
14.8  
15  
14.8  
15  
130  
163  
167  
¹
Natural Gas BTU/h: for alꢀtudes above 2,000, reduce input raꢀng 4% for each 1,000’ above sea level. Low-fire rate is  
75% of high-fire rate.  
²
³
DOE AFUE based upon Isolated Combusꢀon System (ICS).  
Vent diameter may vary depending upon vent length. Refer to the latest ediꢀons of the Naꢀonal Fuel Gas Code NFPA  
54/ANSI Z223.1 (in the USA) and the Canada Naꢀonal Standard of Canada, CAN/CSA B149.1 and CAN/CSA B142.2 (in  
Canada).  
4
5
Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined in ac-  
cordance with Naꢀonal Electrical Codes. Extensive wire runs will require larger wire sizes.  
Refers to maximum recommended fuse or circuit breaker size; may use fuses or HACR-type circuit breakers of the same  
size as noted.  
Notes  
All furnaces are manufactured for use on 115 VAC, 60 Hz, single phase electrical supply.  
Gas Service Connecꢀon ½” FPT  
Important: It is required to size overcurrent protecꢀon device and wires properly and make electrical connecꢀons in ac-  
cordance with the Naꢀonal Electrical Code and/or all exisꢀng local codes.  
SS-GME8  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3
ProDuct sPeciFications  
DiMensions  
Alt. Gas Inlet  
Alt. Gas Inlet  
Alt. High Voltage  
Alt. LowVoltage  
High Voltage Inlet  
Low Voltage  
Model  
GME80703BXA  
GME80905CXA  
GME81155CXA  
A
B
17½”  
21”  
16”  
19½”  
19½”  
21”  
MiniMuM clearances to coMBustiBle Materials  
Vent  
Sides  
Rear  
Front  
Bottom  
Top  
SW  
B
1
0
3
C
6
1
1
C = If placed on combusꢀble ꢁoor, the ꢁoor MUST be wood ONLY.  
Notes:  
For servicing or cleaning, a 24” front clearance is recommended.  
Unit connecꢀons (electrical, ꢁue, and drain) may necessitate greater clearances than the minimum clearances listed above.  
In all cases, accessibility clearance must take precedence over clearances from the enclosure where accessibility clearances are greater.  
Refer to the appropriate USA and Canadian codes:  
In the USA: the Naꢀonal Fuel Gas Code NFPA 54 / ANSI Z223.1  
In Canada: the Canada Naꢀonal Standard of Canada, CAN/CSA B149.1 and CAN/CSA B142.2  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
SS-GME8  
ProDuct sPeciFications  
airFlow Data  
(CFM & Temperature Rise vs. External Static Pressure)  
External Static Pressure, (Inches Water Column)  
Motor  
Speed  
Tons  
AC¹  
Model  
0.1  
0.2  
0.3  
0.4  
0.5  
0.6  
CFM  
556  
756  
964  
0.7  
CFM  
509  
712  
918  
0.8  
CFM  
460  
659  
877  
CFM  
875  
Rise  
59  
50  
43  
38  
33  
53  
49  
42  
38  
31  
58  
52  
49  
46  
37  
CFM  
793  
Rise  
65  
54  
45  
39  
34  
56  
51  
44  
39  
31  
60  
53  
49  
47  
37  
CFM  
736  
Rise  
70  
57  
47  
41  
36  
58  
53  
45  
40  
32  
63  
55  
50  
48  
38  
CFM  
674  
Rise  
77  
60  
49  
42  
37  
61  
55  
47  
41  
32  
65  
57  
51  
49  
40  
CFM  
592  
Rise  
88  
64  
51  
44  
38  
64  
57  
48  
42  
33  
68  
59  
53  
50  
42  
T1  
T2  
T3  
T4  
T5  
T1  
T2  
T3  
T4  
T5  
T1  
T2  
T3  
T4  
T5  
1½  
2
1,032  
1,217  
1,365  
1,549  
1,268  
1,362  
1,576  
1,755  
2,183  
1,466  
1,642  
1,750  
1,870  
2,297  
965  
914  
861  
810  
GME8  
0703BXC*  
2½  
3
1,153  
1,313  
1,505  
1,198  
1,305  
1,519  
1,711  
2,128  
1,415  
1,596  
1,750  
1,805  
2,297  
1,098  
1,268  
1,460  
1,151  
1,261  
1,473  
1,657  
2,094  
1,357  
1,552  
1,707  
1,782  
2,224  
1,051  
1,221  
1,420  
1,092  
1,212  
1,426  
1,627  
2,060  
1,306  
1,499  
1,667  
1,737  
2,106  
1,009  
1,172  
1,378  
1,041  
1,170  
1,398  
1,579  
2,014  
1,248  
1,449  
1,610  
1,701  
2,014  
1,129 1,086 1,054  
1,350 1,305 1,268  
3½  
2½  
3
988  
932  
883  
1,121 1,074 1,021  
1,341 1,290 1,252  
1,548 1,502 1,463  
1,992 1,944 1,847  
1,202 1,144 1,088  
1,388 1,352 1,306  
1,574 1,531 1,486  
1,656 1,606 1,571  
1,896 1,813 1,669  
GME8  
0905CXC*  
3½  
4
5
3
3½  
4
GME8  
1155CXC*  
4
5
¹
@ 0.5” ESP  
Notes  
CFM in chart is without filter(s). Filters do not ship with this furnace, but must be provided by the installer. If the furnace requires two return filters,  
this chart assumes both filters are installed.  
All furnaces ship as high-speed cooling and medium-speed heaꢀng. Installer must adjust blower cooling and heaꢀng speed as needed.  
For most jobs, about 375 - 400 CFM per ton when cooling is desirable.  
INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE.  
This chart is for informaꢀon only. For saꢀsfactory operaꢀon, external staꢀc pressure should not exceed value shown on the raꢀng plate.  
The above chart is for U.S. furnaces installed at 0-2000 feet. At higher alꢀtudes, a properly derated unit will have approximately the same  
temperature rise at a parꢀcular CFM, while ESP at the CFM will be lower.  
Factory Motor Speed Seꢂng: T1 = 1st Stage Ht, T2 = 2nd Stage Ht, T5 = Cooling  
Tempertaure rise data is based on 2nd-stage heat. First-stage heat is 75% of rise indicated above.  
SS-GME8  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5
ProDuct sPeciFications  
wirinG DiaGraM witH Honeywell valve  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
SS-GME8  
ProDuct sPeciFications  
wirinG DiaGraM witH wHite-roDGers valve  
INTEGRATED  
CONTROL MODULE  
HUMIDIFIER  
XFMR (6)  
WARNING:DISCONNECT POWER BEFORE  
SERVICING.WIRING TO UNIT MUST BE  
PROPERLY POLARIZED AND GROUNDED.  
GND  
GND (8)  
MVC (9)  
24 VAC  
HUMIDIFIER  
C2  
GAS  
HI VALVE  
MVH (12)  
MVL (2)  
M1  
C
ID BLOWER  
PRESSURE  
SWITCH  
AUXILIARY  
LIMIT CONTROLS  
C
G
R
W
Y
G
Y
NO  
PS (10)  
PSO (4)  
C
AUTO  
1 STG  
5 MIN  
2 STG MODE  
100 SEC  
150 SEC  
TO  
MICRO HLI (7)  
10 11 12  
WH  
BL  
W
7
4
1
8
5
2
9
6
3
HLO (1)  
AUTO RESET  
PRIMARY  
LIMIT  
FUSE  
R
RO2 (11)  
RO1 (5)  
SEE NOTE 6  
BR  
CONTROL  
AUXILIARY  
LIMITS  
INTEGRATED  
CONTROL MODULE  
MANUAL RESET ROLLOUT  
LIMIT CONTROL(S)  
(SINGLE CONTROL ON SOME MODELS)  
XFMR (3)  
FS  
24 VAC  
40 VA  
BR  
BL  
TRANSFORMER  
XFMR-N  
RD  
XFMR-H  
115 VAC  
FLAME SENSOR  
2
1
FP  
HOT SURFACE  
IGNITER  
XFMR-H  
LINE-H  
EAC-H  
IGN  
IND  
IGN-N  
PARK  
ID  
BLWR  
BK  
IND-N  
BK  
24V  
COOL-H  
CIRCULATOR  
BLWR  
115V  
CIR-N  
XFMR  
WH  
ELECTRONIC  
AIR CLEANER  
BK  
15 PIN PLUG  
ON SOME MODELS  
EAC-H  
LINE-H  
GR  
EAC-N  
BLOWER COMPARTMENT  
LINE-N  
JUNCTION BOX  
BURNER COMPARTMENT  
DOOR  
SWITCH  
24 VAC  
HUMIDIFIER  
DOOR SWITCH  
SWITCH LOCATED IN BLOWER  
COMPARTMENT ON SOME MODELS  
NO  
C
WARNING:  
RD  
RD  
DISCONNECT POWER  
BEFORE SERVICING.  
WIRING TO UNIT  
MUST BE  
PROPERLY  
POLARIZED  
DISCONNECT  
PRESSURE  
SWITCH  
YL  
YL  
PRIMARY LIMIT  
YL  
RD  
YL  
WH  
BK  
AND GROUNDED.  
L
GND  
N
BR  
TO 115VAC/ 1  
OVERCURRENT PROTECTION DEVICE  
Ø /60 HZ POWER SUPPLY WITH  
BL  
WH  
BK  
PM  
1
C
2
HI  
3
JUNCTION  
BOX  
HOT  
SURFACE  
IGNITER  
2 STAGE  
GAS VALVE  
LINE-N  
GND  
LINE H  
PU  
INDUCED DRAFT  
BLOWER  
TO 115 VAC/ 1/60HZ  
POWER SUPPLY WITH  
OVERCURRENT PROTECTION  
DEVICE  
PU  
PU  
FLAME  
SENSOR  
ROLLOUT LIMITS  
(SINGLE CONTROL ON SOME MODELS)  
0
STEADY ON = NORMAL OPERATION  
LOW VOLTAGE (24V)  
LOW VOLTAGE FIELD  
HI VOLTAGE (115V)  
HI VOLTAGE FIELD  
JUNCTION  
EQUIPMENT GND  
FIELD GND  
OFF  
= CONTROL FAILURE  
1
2
3
4
5
6
7
8
C
1 FLASH  
=
SYSTEM LOCKOUT (RETRIES/RECYCLES EXCEEDED)  
2 FLASHES = PRESSURE SWITCH STUCK CLOSED  
3 FLASHES = PRESSURE SWITCH STUCK OPEN  
4 FLASHES = OPEN HIGH LIMIT  
FIELD SPLICE  
SWITCH (TEMP.)  
IGNITER  
5 FLASHES = FLAME SENSE WITHOUT GAS VALVE  
TERMINAL  
6 FLASHES =  
OPEN ROLLOUT OR OPEN FUSE  
SWITCH (PRESS.)  
INTERNAL TO  
INTEGRATED CONTROL  
7 FLASHES = LOW FLAME SIGNAL  
OVERCURRENT  
PROT. DEVICE  
8 FLASHES = CHECK IGNITER OR IMPROPER GROUND  
RAPID FLASHES = REVERSED 115 VAC POLARITY/VERIFY GND  
PLUG CONNECTION  
NOTES:  
1. SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT 0.7 AMPS.  
2. MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE USED WHEN SERVICING.  
PK PINK  
COLOR CODES:  
YL YELLOW  
OR ORANGE  
PU PURPLE  
GR GREEN  
BR BROWN  
WH WHITE  
BL BLUE  
GY GRAY  
RD RED  
3. IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE FURNACE MUST BE REPLACED, IT MUST BE REPLACED WITH  
WIRING MATERIAL HAVING A TEMPERATURE RATING OF AT LEAST 105 °C. USE COPPER CONDUCTORS ONLY.  
4. BLOWER SPEEDS SHOULD BE ADJUSTED BY INSTALLER TO MATCH THE INSTALLATION REQUIREMENTS SO AS TO  
PROVIDE THE CORRECT HEATING TEMPERATURE RISE AND THE CORRECT COOLING CFM. (SEE SPEC SHEET FOR AIR  
FLOW CHART)  
5. UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N.E.C. AND LOCAL CODES.  
6. TO RECALL THE LAST 5 FAULTS, MOST RECENT TO LEAST RECENT, DEPRESS SWITCH FOR MORE THAN 2 SECONDS  
WHILE IN STANDBY(NO THERMOSTAT INPUTS).  
BK BLACK  
0140F00643 REV. A  
SS-GME8  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7
ProDuct sPeciFications  
Dual$aver conFiGuration oPeration  
&
Dual$aver™  
This furnace is capable of the following heating modes:  
Single Stage (Factory Setting)  
Modified Two-Stage  
»
»
Fixed 5-Min Low Stage  
Auto Time (1-12 Min) Low Stage  
Start  
Call for Heat  
Safety Circuit Check  
Start Furnace  
in Low Stage  
Low-Heat Blower  
Delay Time (5 Min)  
or Delay Time (1-12 Min)  
Gas Valve Switch  
to 2nd Stage  
Blower Switch to  
Hi Heat Operaꢀon  
T-Stat Saꢀsfied  
accessories  
GME8  
0703BX  
GME8  
0905CX  
GME8  
155CX  
Model  
Description  
LPM-05  
LPM-06  
LP Conversion Kit (Springs & Orifice)¹  
LP Conversion Kit (Springs & Orifice)²  
FSRKG-14/17/21/24 Noise Reducꢀon Kits  
MVK-01³  
HA02  
Masonry Vent Kit  
High-Alꢀtude Natural Gas Kit  
Fossil Fuel Kit  
AFE18-60A  
¹
²
³
White-Rodgers valves only  
Honeywell or White-Rodgers valves  
Upꢁow applicaꢀons only  
Goodman Manufacturing Company, L.P., reserves the right to discontinue, or change at any time, specifications or designs without  
notice or without incurring obligations. © 2010 • Goodman Manufacturing Company, L.P. Houston, Texas • Printed in the USA.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
SS-GME8  

Eiki Network Card LC XNB3W User Manual
Electro Voice Car Speaker sb121a 110v User Manual
Estate Range W10173755D User Manual
Fellowes Laminator L80 95 User Manual
Fellowes Paper Shredder SB 125Ci User Manual
First Alert Home Security System 3035DEF User Manual
Garland Convection Oven ECO E 10 E User Manual
GE Heat Pump AZ58H12E User Manual
Generac Portable Generator 005882 1 User Manual
Goodman Mfg Heat Pump GSZ11 User Manual