GMV95/GCV9
MULTI-POSITION,
TWO-STAGE/VARIABLE-SPEED
GAS FURNACE
PRODUCT SPECIFICATIONS
The Goodman® brand GMV95/ GCV9 Two-Stage, Variable-
Speed Gas Furnaces feature a patented aluminized-steel
tubular heat exchanger and durable Silicon Nitride Hot
Surface Ignition system.
Standard Features
•
Patented TuffTube™ dual-diameter tubular heat exchanger
with Lifetime Limited Warranty* for as long as the original
registered homeowner owns their home plus 10-Year Limited
Unit Replacement Warranty*
•
•
Two-stage gas valve operates with two-stage or single-
stage thermostats
Efficient and quiet variable-speed circulator motor gently ramps
up or down according to heating or cooling demand
110V Silicon Nitride igniter designed for long igniter life
Furnace control board with self-diagnostics, color-coded low-
voltage terminals, and provisions for electronic air cleaner and
120-volt or 24-volt humidifiers
•
•
•
•
Low constant fan allows homeowner to activate very low
speed to efficiently circulate air throughout the home. This
setting costs as little as a 100-watt light bulb to operate.
Dual-certified for sealed combustion direct vent (2-pipe)
or non-direct vent (1-pipe) applications
Applies to 95% furnaces only.
•
•
Quiet two-speed induced draft blower
All models comply with California NOx emissions standards
GMV95: UP TO 95% AFUE
GCV9: UP TO 93% AFUE
Cabinet Features
•
Fully insulated, heavy-gauge steel cabinet with durable
baked-enamel finish
•
•
Foil-faced insulation lines the heat exchanger
Easy-to-install top venting is standard; alternate flue/vent
located on the right (GMV95)
Designed for multi-position installation – GMV95: upflow,
horizontal left or right; GCV9: downflow, horizontal left or right
Airtight solid bottom for side return applications and easy-cut
tabs for effortless removal in bottom air inlet applications
Convenient left or right connection for gas and electric service
Coil and furnace fit flush for most installations
HEATING INPUT: 46,000–115,000 BTU/H
•
•
•
•
Contents
Nomenclature ................................................................................................2
Product Specifications ................................................................................3
Dimensions .....................................................................................................4
Blower Performance Specifications........................................................7
Wiring Diagrams.........................................................................................13
Accessories...................................................................................................15
*To receive the Lifetime Heat Exchanger Limited Warranty, 10-Year Unit Replacement Limited Warranty and
10-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online
SS-GMV95
Download from Www.Somanuals.com. All Manuals Search And Download.
6/09
Supersedes 3/09
PRODUCT SPECIFICATIONS
SPECIFICATIONS
GMV95
GMV95
GMV95
GMV95-
GCV9
GCV9
GCV9
0453BXB 0704CXB 0905DXB 1155DXB 0704CXB 0905DXB 1155DXA
Heating Capacity
High Fire Input¹
46,000
45,000
32,000
30,800
95
69,000
67,000
48,000
46,400
95
92,000
90,000
64,000
61,700
95
115,000
109,000
80,000
77,400
95
69,000
65,000
48,000
45,000
93
92,000
87,000
64,000
60,100
93
115,000
109,000
80,000
77,400
93
High Fire Output¹
Low Fire Input¹
Low Fire Output¹
AFUE²
Tons AC @ 0.5” ESP
Temperature Rise Range (°F)
Circulator Blower
Size (D x W)
1.5 - 3.0
30 - 60
1.5 - 4.0
30 - 60
2.0 - 5.0
30 - 60
2.0 - 5.0
30 - 60
1.5 - 4.0
30 - 60
2.0 - 5.0
30 - 60
2.0 - 5.0
40-70
10” X 7”
½
10” X 10”
¾
11” X 10”
1
11” X 10”
1
10” x 10”
¾
11” X 10”
11” X 10”
1
Horespower @ 1750 RPM
Speed
1
Variable
Variable
Vent Diameter³
2”
2
2”
3
3”
4
3”
5
2”
3
3”
4
3”
5
No. of Burners
Filter Size (in²)
Disposable
288
576
384
768
480
960
486
972
384
768
480
960
486
972
Permanent
Electrical Data
Min. Circuit Ampacity (amps)4
Max. Overcurrent Protection5
Ship Weight (lbs)
1– Natural Gas BTU/h
10.4
15 amps
133
12.8
15 amps
135
14.6
15 amps
172
14.6
15 amps
175
12.8
15 amps
135
14.6
15 amps
172
14.6
15 amps
175
2– DOE AFUE based upon Isolated Combustion System (ICS)
3– Installer must supply one or two PVC pipes: one for combustion air (optional) and one for the flue outlet (required). Vent pipe must
be either 2”or 3”in diameter, depending upon furnace input, number of elbows, length of run and installation (1 or 2 pipes). The
optional Combustion Air Pipe is dependent on installation/code requirements and must be 2”or 3”diameter PVC.
4– Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined in accordance with
National Electrical Codes. Extensive wire runs will require larger wire sizes.
5– Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size. May use fuses or HACR-type
circuit breakers of the same size as noted.
Notes:
•
All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply.
•
•
Gas Service Connection ½” FPT
Important: Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code
and/or all existing local codes.
SS-GMV95
3
Download from Www.Somanuals.com. All Manuals Search And Download.
PRODUCT SPECIFICATIONS
GMV95 DIMENSIONS
Model
A
B
C
D
E
GMV950453BXB
GMV950704CXB
GMV950905DXB
GMV951155DXB
17½”
21”
16”
13⅛”
16⅛”
20⅝”
20⅝”
12⅛”
16
13⅝”
17½”
20⅞”
20⅞”
19½”
23”
24½”
24½”
19⅜”
19⅜”
23”
Notes:
•
Installer must supply one or two PVC pipes: one for combustion air (optional) and one for the flue outlet (required). Vent pipe must be
either 2” or 3” in diameter, depending upon furnace input, number of elbows, length of run and installation
(1 or 2 pipes). The optional Combustion Air Pipe is dependent on installation/code requirements and must be 2” or 3” diameter PVC.
Line voltage wiring can enter through the right or left side of the furnace. Low-voltage wiring can enter through the right or left side of
furnace.
•
•
•
Conversion kits for high-altitude natural gas operation are available. Contact your Goodman distributor or dealer for details.
Installer must supply following gas line fittings, according to which entrance is used:
Left—Two 90º elbows, one close nipple, straight pipe
Right—Straight pipe to reach gas valve
•
For bottom return: Failure to unfold flanges may reduce airflow by up to 18%. This could result in performance and noise issues.
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS
Position
Upflow
Sides
0”
Rear
0”
Front
3”
Bottom
Flue
0”
Top
1”
C
C
Horizontal
6”
0”
3”
0”
6”
C = If placed on combustible floor, the floor MUST be wood ONLY.
Notes:
•
•
•
For servicing or cleaning, a 24” front clearance is required.
Unit connections (electrical, flue and drain) may necessitate greater clearances than the minimum clearances listed above.
In all cases, accessibility clearance must take precedence over clearances from the enclosure where accessibility clear-
ances are greater.
4
SS-GMV95
Download from Www.Somanuals.com. All Manuals Search And Download.
PRODUCT SPECIFICATIONS
GCV9 DIMENSIONS
FOLDED FLANGES
FOLDED FLANGES
UNFOLDED FLANGES
UNFOLDED FLANGES
Model
GCV90704CXB
GCV90905DXB
A
B
C
D
E
21”
19½”
23”
16⅛”
20⅝”
20⅝”
18”
19½”
23”
24½”
24½”
21½”
21½”
GCV91155DXB
23”
23”
Notes:
•
Installer must supply one or two PVC pipes: one for combustion air (optional) and one for the flue outlet (required). Vent pipe must be
either 2” or 3” in diameter, depending upon furnace input, number of elbows, length of run, and installation (1 or 2 pipes). The optional
Combustion Air Pipe is dependent on installation/code requirements and must be 2” or 3” diameter PVC.
Line voltage wiring can enter through the right or left side of the furnace. Low-voltage wiring can enter through the right or left side of
furnace.
•
•
•
Conversion kits for high-altitude natural gas operation are available. Contact your Goodman distributor or dealer for details.
Installer must supply following gas line fittings, according to which entrance is used:
Left—Two 90º Elbows, one close nipple, straight pipe
Right—Straight pipe to reach gas valve
•
For bottom return: Failure to unfold flanges may reduce airflow by up to 18%. This could result in performance and noise issues.
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS
Position
Downflow
Horizontal
Sides
0”
Rear
0”
Front
3”
Bottom
NC
Flue
0”
Top
1”
6”
0”
3”
C
0”
6”
C = If placed on combustible floor, the floor MUST be wood ONLY.
NC = For installation on non-combustible floors only. A combustible floor sub-base must be used for installations on combustible flooring.
Notes:
•
•
•
For servicing or cleaning, a 24” front clearance is required.
Unit connections (electrical, flue and drain) may necessitate greater clearances than the minimum clearances listed above.
In all cases, accessibility clearance must take precedence over clearances from the enclosure where accessibility clearances
are greater.
SS-GMV95
5
Download from Www.Somanuals.com. All Manuals Search And Download.
PRODUCT SPECIFICATIONS
GMV95 HIGH- OR SINGLE-STAGE COOLING SPEEDS
GMV950453BXB
GMV950704CXB
GMV950905DXB
GMV951155DXB
Cooling
Speed Tap
Adjust
Tap
Cooling
Speed Tap
Adjust
Tap
Cooling
Speed Tap
Adjust
Tap
Cooling
Speed Tap
Adjust
Tap
CFM¹
CFM¹
CFM¹
CFM¹
Minus (-) 540
Minus (-) 540
Minus (-) 720
Minus (-) 720
A
Normal
Plus (+)
600
660
A
Normal
Plus (+)
600
660
A
Normal
Plus (+)
800
880
A
Normal
Plus (+)
800
880
Minus (-) 720
Minus (-) 720
Minus (-) 990
Normal 1,100
Plus (+) 1,210
Minus (-) 1,260
Normal 1,400
Plus (+) 1,540
Minus (-) 1,620
Normal 1,800
Plus (+) 1,980
Minus (-) 990
Normal 1,100
Plus (+) 1,210
Minus (-) 1,260
Normal 1,400
Plus (+) 1,540
Minus (-) 1,620
Normal 1,800
Plus (+) 1,980
B
C
D
Normal
Plus (+)
800
880
B
C
D
Normal
Plus (+)
800
880
B
C
D
B
C
D
Minus (-) 900
Normal 1,000
Plus (+) 1,100
Minus (-) 1,080
Normal 1,200
Plus (+) 1,320
Minus (-) 990
Normal 1,100
Plus (+) 1,210
Minus (-) 1,286
Normal 1,429
Plus (+) 1,572
¹
@ .1” to .8” W.C. ESP
Notes:
•
•
•
•
All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed.
For most jobs, about 400 CFM per ton when cooling is desirable.
Do not operate above .5” w.c. ESP in heating mode. Operating CFM between .5” and .8” w.c. is tabulated for cooling purposes only.
Constant Fan mode is 50% of above values
GMV95 LOW-STAGE COOLING SPEEDS
GMV950453BXB
GMV950704CXB
GMV950905DXB
GMV951155DXB
Cooling
Speed
Tap
Cooling
Speed Tap
Adjust
Tap
Cooling
Speed Tap
Adjust
Tap
Cooling
Speed Tap
Adjust
Tap
Adjust
Tap
CFM¹
CFM¹
CFM¹
CFM¹
Minus (-) 380*
Minus (-) 378*
Minus (-) 513*
Minus (-) 514*
A
Normal
Plus (+)
390
429
A
B
C
D
Normal
Plus (+)
390
429
A
Normal
Plus (+)
520
572
A
B
C
D
Normal
Plus (+)
520
572
Minus (-) 468
Minus (-) 468
Minus (-) 644
Minus (-) 644
B
C
D
Normal
Plus (+)
520
572
Normal
Plus (+)
520
572
B
C
D
Normal
Plus (+)
715
787
Normal
Plus (+)
715
787
Minus (-) 585
Minus (-) 644
Minus (-) 819
Normal 910
Minus (-) 819
Normal 910
Normal
Plus (+)
650
715
Normal
Plus (+)
715
787
Plus (+) 1,001
Minus (-) 1,053
Normal 1,170
Plus (+) 1,287
Plus (+) 1,001
Minus (-) 1,053
Normal 1,170
Plus (+) 1,287
Minus (-) 702
Minus (-) 836
Normal 929
Plus (+) 1,022
Normal
Plus (+)
780
858
¹
@ .1” to .8” W.C. ESP
Notes:
•
•
•
All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed.
For most jobs, about 400 CFM per ton when cooling is desirable.
Do not operate above .5” w.c. ESP in heating mode. Operating CFM between .5” and .8” w.c. is tabulated for cooling purposes only.
6
SS-GMV95
Download from Www.Somanuals.com. All Manuals Search And Download.
PRODUCT SPECIFICATIONS
GMV95 HEATING SPEEDS
GMV950453BXB
(Rise Range: 30° - 60°F)
GMV950704CXB
(Rise Range: 30° - 60°F)
Heating
Speed
Tap
Low Stage
CFM @ .1” to
.5” W.C. ESP
High Stage
CFM @ .1” to
.5” W.C. ESP
Heating
Speed
Tap
Low Stage
CFM @ .1” to CFM @ .1” to
.5” W.C. ESP .5” W.C. ESP
High Stage
Adjust
Tap
Rise
(°F)
Adjust
Tap
Rise
(°F)
Minus (-)
Normal
Plus (+)
Minus (-)
Normal
Plus (+)
Minus (-)
Normal
Plus (+)
Minus (-)
Normal
495
550
605
540
600
660
585
650
715
630
700
770
713
792
871
778
864
950
842
936
1,030
907
57
51
46
52
47
43
48
43
39
45
40
36
Minus (-)
Normal
Plus (+)
Minus (-)
Normal
Plus (+)
Minus (-)
Normal
Plus (+)
Minus (-)
Normal
756
840
924
828
920
1,012
900
1,000
1,100
972
1,089
1,210
1,331
1,192
1,325
1,457
1,296
1,440
1,584
1,400
1,555
1,711
56
50
46
51
46
42
47
42
38
43
39
35
A
B
C
D
A
B
C
D
1,008
1,109
1,080
1,188
Plus (+)
Plus (+)
GMV950905DXB
GMV951155DXB
(Rise Range: 30° - 60°F)
(Rise Range: 30° - 60°F)
Heating
Speed
Tap
Low Stage
CFM @ .1” to
.5” W.C. ESP
High Stage
CFM @ .1” to
.5” W.C. ESP
Heating
Speed
Tap
Low Stage
CFM @ .1” to CFM @ .1” to
.5” W.C. ESP .5” W.C. ESP
High Stage
Adjust
Tap
Rise
(°F)
Adjust
Tap
Rise
(°F)
Minus (-)
Normal
Plus (+)
Minus (-)
Normal
Plus (+)
Minus (-)
Normal
Plus (+)
Minus (-)
Normal
1,013
1,125
1,238
1,076
1,195
1,315
1,139
1,265
1,392
1,202
1,335
1,469
1,458
1,620
1,782
1,549
1,721
1,893
1,639
1,822
2,004
1,730
1,922
2,115
56
50
45
52
47
43
49
44
40
47
42
38
Minus (-)
Normal
Plus (+)
Minus (-)
Normal
Plus (+)
Minus (-)
Normal
Plus (+)
Minus (-)
Normal
1,107
1,230
1,353
1,139
1,265
1,392
1,170
1,300
1,430
1,202
1,335
1,469
1,594
1,771
1,948
1,639
1,822
2,004
1,685
1,872
2,059
1,730
1,922
2,115
63
57
52
62
56
50
60
54
49
58
53
48
A
B
C
D
A
B
C
D
Plus (+)
Plus (+)
SS-GMV95
7
Download from Www.Somanuals.com. All Manuals Search And Download.
PRODUCT SPECIFICATIONS
GMV95 BLOWER PERFORMANCE
8
SS-GMV95
Download from Www.Somanuals.com. All Manuals Search And Download.
PRODUCT SPECIFICATIONS
GCV9 COOLING SPEEDS
HIGH- /SINGLE-STAGE & LOW-STAGE COOLING SPEEDS
GCV90704CXA
CFM at .1” to .8” w.c. ESP
Cooling
Speed
Tap
Adjust
Tap
High/Single-
Low Stage
Stage
Minus (-)
Normal
Plus(+)
Minus (-)
Normal
Plus(+)
Minus (-)
Normal
Plus(+)
Minus (-)
Normal
Plus(+)
378*
390
429
468
520
572
644
715
787
836
929
1,022
540
600
A
B
C
D
660
720
800
880
990
1,100
1,210
1,286
1,429
1,572
GCV90905DXA
CFM at .1” to .8” w.c. ESP
Cooling
Speed
Tap
Adjust
Tap
High/Single-
Low Stage
Stage
Minus (-)
Normal
Plus(+)
Minus (-)
Normal
Plus(+)
Minus (-)
Normal
Plus(+)
Minus (-)
Normal
Plus(+)
513*
520
720
800
*
Motor CFM maximum
A
B
C
D
572
880
644
990
715
1,100
1,210
1,260
1,400
1,540
1,620
1,800
1,980
787
GCV91155DXA
819
CFM at .1” to .8” w.c. ESP
Cooling
910
Adjust
Tap
Speed
Tap
High/Single-
Low Stage
1,001
1,053
1,170
1,287
Stage
Minus (-)
Normal
Plus(+)
Minus (-)
Normal
Plus(+)
Minus (-)
Normal
Plus(+)
Minus (-)
Normal
Plus(+)
500*
508
705
783
A
B
C
D
559
861
621
982
*
Motor CFM maximum
690
1,091
1,200
1,265
1,406
1,547
1,628
1,809
1,990
759
815
906
997
1,049
1,165
1,282
*
Motor CFM maximum
Notes:
•
These charts are for furnaces installed at 0 - 2000 feet. At higher altitudes, a properly derated unit will have the same temperature rise at a
particular CFM, while the ESP at that CFM will be lower.
•
•
•
The installation must be adjusted to obtain a temperature rise within the range listed on the furnace nameplate.
Do not operate above .5” w.c. ESP in heating mode.
Propane gas installations will have a High Stage rise approximately 4° lower than shown in above table.
SS-GMV95
9
Download from Www.Somanuals.com. All Manuals Search And Download.
PRODUCT SPECIFICATIONS
GCV9 COOLING SPEEDS (CONT.)
COOLING-BASED CONTINUOUS FAN SPEEDS
GCV90704CXA
Continuous
GCV90905DXA
Continuous
GCV91155DXA
Continuous
Cooling
Speed Tap
Adjust
Tap
Cooling
Cooling
Fan Speed
CFM
Adjust Tap Fan Speed
CFM
Adjust Tap Fan Speed
CFM
Speed Tap
Speed Tap
Minus (-)
Normal
Plus(+)
Minus (-)
Normal
Plus(+)
Minus (-)
Normal
Plus(+)
Minus (-)
Normal
Plus(+)
380*
380*
380*
403
448
493
554
616
678
720
800
880
Minus (-)
Normal
Plus(+)
Minus (-)
Normal
Plus(+)
Minus (-)
Normal
Plus(+)
Minus (-)
Normal
Plus(+)
513*
513*
513*
554
Minus (-)
Normal
Plus(+)
Minus (-)
Normal
Plus(+)
Minus (-)
Normal
Plus(+)
Minus (-)
Normal
Plus(+)
500*
500*
500*
550
A
B
C
D
A
B
C
D
A
B
C
D
616
611
678
672
706
709
784
787
862
866
907
912
1,008
1,109
1,013
1,114
*
Motor CFM maximum
AUTO-COMFORT MODE
During Auto-Comfort mode, the furnace ramps up to 50% of the demand for half a minute. It then
ramps to 82% of the full cooling demand airflow and operates there for approximately 7½ minutes.
The motor then steps up to the full demand airflow. This mode spends a half minute at 50% airflow
OFF delay.
STANDARD ALTITUDE INSTALLATIONS
Manifold Pressure
Pressure Switch
Change
Gas
Altitude
Kit
Orifice
High Stage
Low Stage
1.9” W.C.
6.0” W.C.
Natural
0-7000 Changeover
0-7000
None
#43
#55
3.5” W.C.
None
None
Propane
LPM-03B & LPM-05
10.0: W.C.
•
•
For installation in Canada, gas furnaces are certified only to 4,500 ft.
For GCVA installations above 7,000 ft., please refer to your Goodman distributor for required kit(s).
10
SS-GMV95
Download from Www.Somanuals.com. All Manuals Search And Download.
PRODUCT SPECIFICATIONS
GCV9 HEATING SPEEDS
GCV90704CXA (Rise Range: 30 - 60°F)
Heating
Speed Tap
Adjust
Tap
Low-Stage High-Stage
Rise
CFM
CFM
Minus (-)
Normal
Plus(+)
Minus (-)
Normal
Plus(+)
Minus (-)
Normal
Plus(+)
Minus (-)
Normal
Plus(+)
747
830
1,076
1,195
1,315
1,186
1,318
1,449
1,296
1,440
1,584
1,408
1,562
1,719
56
50
46
51
46
42
47
42
38
43
39
35
A
B
C
D
913
824
915
1,007
900
GCV90905DXA (Rise Range: 30 - 60°F)
1,000
1,100
978
Heating
Speed Tap
Adjust
Tap
Low-Stage High-Stage
Rise
CFM
CFM
1,085
1,194
Minus (-)
Normal
Plus(+)
Minus (-)
Normal
Plus(+)
Minus (-)
Normal
Plus(+)
Minus (-)
Normal
Plus(+)
999
1,439
1,598
1,758
1,536
1,706
1,876
1,633
1,814
1,996
1,730
1,922
2,115
56
50
46
52
47
43
49
44
40
46
42
38
A
B
C
D
1,110
1,221
1,067
1,185
1,303
1,134
1,260
1,386
1,202
1,335
1,469
GCV91155DXA (Rise Range: 30 - 60°F)
Heating
Speed Tap
Adjust
Tap
Low-Stage High-Stage
Rise
CFM
CFM
Minus (-)
Normal
Plus(+)
Minus (-)
Normal
Plus(+)
Minus (-)
Normal
Plus(+)
Minus (-)
Normal
Plus(+)
1,093
1,214
1,335
1,106
1,229
1,352
1,166
1,296
1,426
1,172
1,302
1,432
1,583
1,759
1,935
1,612
1,791
1,970
1,654
1,838
2,022
1,690
1,878
2,066
63
56
51
61
55
50
60
54
49
59
53
48
A
B
C
D
Notes:
•
These charts are for furnaces installed at 0 - 2000 feet. At higher altitudes, a properly derated unit will have the same temperature rise at a
particular CFM, while the ESP at that CFM will be lower.
•
•
•
The installation must be adjusted to obtain a temperature rise within the range listed on the furnace nameplate.
Do not operate above .5” w.c. ESP in heating mode.
Propane gas installations will have a High Stage rise approximately 4° lower than shown in above table.
SS-GMV95
11
Download from Www.Somanuals.com. All Manuals Search And Download.
PRODUCT SPECIFICATIONS
GCV9 BLOWER PERFORMANCE
12
SS-GMV95
Download from Www.Somanuals.com. All Manuals Search And Download.
PRODUCT SPECIFICATIONS
GMV95/ GCV9 WIRING DIAGRAM
SS-GMV95
13
Download from Www.Somanuals.com. All Manuals Search And Download.
PRODUCT SPECIFICATIONS
GMV95/ GCV9 BLOWER ASSEMBLY SCHEMATIC
1
2
3
4
5
N I
N I
N I
N I
N I
P
P
P
P
P
LINE
XFMR
EAC
CIRC
HUM
HUM
XFMR
LINE
PARK
COOL
EAC
HI
HEAT
SINGLE
TWO
LO
HEAT
This schematic is for reference only. Not all wiring is as shown above.
Refer to the appropriate wiring diagram for the unit being serviced.
14
SS-GMV95
Download from Www.Somanuals.com. All Manuals Search And Download.
PRODUCT SPECIFICATIONS
GMV95/ GCV9 SCHEMATICS (CONT.)
WR 50V61-289 INTEGRATED IGNITION CONTROL
This schematic is for reference only. Not all wiring is as shown above. Refer to the appropriate wiring diagram for the unit being serviced.
SS-GMV95
15
Download from Www.Somanuals.com. All Manuals Search And Download.
PRODUCT SPECIFICATIONS
ACCESSORIES
Model
GMV95
GMV95
GMV95
GMV95
GCV9
GCV9
GCV9
Description
0453BXB 0704CXB 0905DXB 1155DXB 0704CXB 0905DXB 1155DXB
LPM-03B
LPM-05
GSAS
LP Conversion Kit (Gas Valve)
1
1
√
1
1
√
1
1
√
1
1
√
1
1
√
1
1
√
LP Conversion Kit (Springs & Orifice)
Electronic Air Cleaners (-10, -11, -12 or -18)
Media Air Cleaners
(1620, 2020, 1625 or 2025)
GMU
√
√
√
√
√
√
√
√
√
√
DEHUM1
HAPS28
HAPS29
HAPS 31
HALP11
HALP 13
HANG 13
HANG 14
HANG 16
EFR01
Dehumidistat
√
√
High-Altitude Pressure Switch Kit
High-Altitude Pressure Switch Kit
High-Altitude Pressure Switch Kit
High-Altitude Propane Gas Kit
High-Altitude Propane Gas Kit
High-Altitude Natural Gas Kit
High-Altitude Natural Gas Kit
High-Altitude Natural Gas Kit
External Filter Rack
2
2
2
2
2
2
2
2
2
2
2
2
3
4
3
4
3
4
3
4
2
√
√
√
√
2
√
√
√
√
√
√
√
√
√
√
√
√
DCVK-20
DCVK-30
CFB21
Horizontal/Vertical Concentric Vent Kit (2”)
Horizontal/Vertical Concentric Vent Kit (3”)
Downflow Floor Base
√
CFB24
Downflow Floor Base
√
√
017K00000S
Flush-mount vent kit
√
√
√
√
√
1– All Models up to 7,000’ 2– 7,001’ to 11,000’ 3– 7,001’ to 9,000’ 4– 9,001’ to 11,000’
Note: All installations above 7,000’ require a pressure switch change. For installation in Canada, gas furnaces are certified
only to 4,500’.
THERMOSTATS
A two-stage thermostat should be used with the GMV95/GCV9 furnaces. Two-stage thermostats control which firing rate is
used depending on the temperature difference between the set point and the room temperature. A properly used two-stage
thermostat and furnace will maintain a much tighter
Model
CHT90-120
CH70TG
Description
Cooling/Heating, Mechanical
Cooling/Heating, Digital, Non-programmable
Cooling/Heating, Mechanical
Heating Only, Mechanical
control of temperature than a conventional single-stage
thermostat and furnace. Two-stage furnaces have “W1”
and “W2” terminals. If the thermostat has “Y1” and “Y2”
cooling connections and a single-stage cooling system
is used, connect “Y” on the furnace control to “Y1” on
the thermostat. The table below describes two-stage
thermostats that have been configured for use with this
furnace.
CHSATG
H20TWR
Goodman Manufacturing Company, L.P., reserves the right to discontinue, or change at any time, specifications or designs without notice
or without incurring obligations. © 2008-2009 • Goodman Manufacturing Company, L.P. • Houston, Texas • Printed in the USA.
16
SS-GMV95
Download from Www.Somanuals.com. All Manuals Search And Download.
|