Goodman Mfg Air Conditioner CE COMMERCIAL SPLIT SYSTEM AIR CONDITIONER User Manual |
CE COMMERCIAL
SPLIT SYSTEM AIR CONDITIONER
PRODUCT SPECIFICATIONS
The CE Commercial 10-ton split system air
conditioner features the unique Goodman®
sound control top design for quiet operation
and is designed for ground-level or rooftop
mount application.
Standard Features
• Single-scroll compressor with crankcase heater
• Quiet operating top discharge
• Permanently lubricated condenser motor
• Copper tube/aluminum fin coil
• Brass suction ball valve and liquid front-seating shut-off
valve with sweat connections
• Large-capacity liquid line filter dryer
• High- and low-pressure switches
• Contactor with lug connections
• Ground lug connection
• ETL Listed
Cabinet Features
• Unique Goodman® sound control top design
• Steel louver coil guard protects the coil from
damage and adds strength to unit
• Bottom pan rails elevate unit above slab
• Heavy-gauge galvanized-steel cabinet
• Attractive Architectural Gray powder-paint finish with 500-
hour salt-spray approval
50 HZ, 10-TON
• When properly anchored, meets the 2001 Florida Building
Code unit integrity requirements for
hurricane-type winds
NOMINAL COOLING CAPACITY:
120,000 BTU/H [35.2 KW]
SS-CE120
11/06
Supersedes 10/06
Download from Www.Somanuals.com. All Manuals Search And Download.
PRODUCT SPECIFICATIONS
SPECIFICATIONS
Capacities
CE120-5
114,000
9.0
Condenser Fan / Coil
Horsepower - RPM
Fan Diameter/ # Fan Blades
Outdoor Nominal CFM
Face Area (ft²)
CE120-5
1-930
26/3
Nominal Cooling (BTU/h)
EER¹
Decibels
84
4,400
29.4
Compressor
RLA / LRA
17.2 / 118
380-420
Rows Deep/ Fins per Inch
Fin Type
1/22
Volts
Ripple
40
Condenser Fan Motor
Horsepower / FLA
Volts
Coil No. of Tubes
1 / 2
380
Coil Tube Diameter
Electrical Data
⅜”
Refrigeration System
Liquid Valve Size (“O.D.)
Suction Valve Size (“O.D.)
Valve Type
Voltage-Hz / Phase
Min. Circuit Ampacity²
Max. Overcurrent Protection³
Min / Max Volts
380/415-50/3
23.6
⅝”
1⅛”
40 amps
342/456
½” or ¾”
296 [134]
Sweat
32
Refrigerant Charge
Power Supply Conduit Size
Ship Weight (lbs-[kg])
1 Energy Efficiency Ratio
2 Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.
3 May use fuses or HACR-type circuit breakers of the same size as noted.
Note: Always check the S&R plate for electrical data on the unit being installed.
PERFORMANCE RATINGS
Cooling Capacity
Outdoor
Indoor Unit
dBs
Unit
Total BTU/h
114,000
Sensible BTU/h
83,000
EER¹
9.0
kWI²
12.67
12.67
AR-120-2
CE120-5
84
(2) CA*F4860*6*
114,000
83,000
9.0
1 Energy Efficiency Ratio
2 kWI = Compressor + Indoor Blower + Outdoor Fan Watts
SS-CE120
3
Download from Www.Somanuals.com. All Manuals Search And Download.
PRODUCT SPECIFICATIONS
EXPANDED PERFORMANCE RATINGS — CE120-5 / AR120-00-5
4
SS-CE120
Download from Www.Somanuals.com. All Manuals Search And Download.
PRODUCT SPECIFICATIONS
EXPANDED PERFORMANCE RATINGS— CE120-5 / AR120-00-5 (CONT.)
SS-CE120
5
Download from Www.Somanuals.com. All Manuals Search And Download.
PRODUCT SPECIFICATIONS
DIMENSIONS
W
D
H
Dimensions
W x D x H
Model
CE120-5
35½ x 35½ x 41½
6
SS-CE120
Download from Www.Somanuals.com. All Manuals Search And Download.
PRODUCT SPECIFICATIONS
SCHEMATIC DIAGRAM
LVJB
CONTROL BOX
OUTDOOR POWER SUPPLY
SEE RATING PLATE
YL
BL
Y
C
NOTE 1
T1
T3
L1
T2
L3
L2
C
C
C
LVJB
IO
COLOR CODE
L2
BK --------------- BLACK
BL --------------- BLUE
C
COMP
BR --------------- BROWN
L1
YL
OR --------------- ORANGE
FC
L3
PU --------------- PURPLE
RD --------------- RED
WH -------------- WHITE
YL --------------- YELLOW
YL/BK ---------- YELLOW w/BLACK
HASH MARKS
IO
BL
BK RD
BK RD
WIRING CODE
FACTORY WIRING
HIGH VOLTAGE
LOW VOLTAGE
OPTIONAL HIGH VOLTAGE
CM
T2 T3
YL
T1
L1
CH
YL/BK
L2 L3
C
FIELD WIRING
HIGH VOLTAGE
LOW VOLTAGE
RD
BK
BK
C
PU
FC
BR
BK
LPS
YL/BK
HPS
BK
YL/BK
BK
Y
C
COMPONENT CODE
C --------------- CONTACTOR
CM ------------ OUTDOOR FAN MOTOR
COMP -------- COMPRESSOR
FC ------------- FAN CAPACITOR
IO -------------- INTERNAL OVERLOAD
LVJB ---------- LOW VOLTAGE JUNCTION BOX
CH ------------ CRANKCASE HEATER
LPS
YL
EQUIPMENT GROUND
USE COPPER
CONDUCTORS ONLY
BK
YL
L3
NOTES:
1) TO INDOOR UNIT LOW VOLTAGE
TERMINAL BLOCK & INDOOR
THERMOSTAT.
RD
L1
MAIN
AUX
BK
BK
PU
BR
BK
CH
HPS
USE N.E.C. CLASS 2 WIRE
CONTROLS SHOWN WITH THERMOSTAT IN 'OFF' POSITION.
IO
LPS ----------- LOW PRESSURE SWITCH
HPS ---------- HIGH PRESSURE SWITCH
L2
COMP
BK
CM
0140R00092
ACCESSORIES
Model
FSK01A¹
CHTD18-60
CHT18-60
LA-01
Description
Freeze Protection Kit
Digital room thermostat with 1-stage cool/1-stage heat
Standard room thermostat with 1-stage cool/1-stage heat
Low Ambient Kit
¹
Installed on indoor coil
SS-CE120
7
Download from Www.Somanuals.com. All Manuals Search And Download.
PRODUCT SPECIFICATIONS
NOTES
Goodman Manufacturing Company, L.P., reserves the right to discontinue, or change at any time, specifications or designs without notice or without
incurring obligations. Copyright © 2006-2008 • Goodman Manufacturing Company, L.P. • Houston, Texas • Printed in the USA.
8
SS-CE120
Download from Www.Somanuals.com. All Manuals Search And Download.
|