		 LG   
					LG   
					Room Air Conditioner   
					OWNER'S MANUAL   
					Prior to installation, this air-conditioning   
					unit must be submitted for approval by   
					the utility service which provides   
					electricity   
					(EN 61000-2, EN 61000-3 Norm).   
					IMPORTANT   
					• Please read this owner's manual carefully and thoroughly   
					before installing and operating your room air conditioner.   
					• Please retain this owner's manual for future reference after   
					reading it thoroughly.   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Safety Precautions   
					Safety Precautions   
					To prevent the injury of the user or other people and property damage, the following instructions must be   
					followed.   
					■ Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classified by   
					the following indications.   
					This symbol indicates the possibility of death or serious injury.   
					This symbol indicates the possibility of injury or damage to properties only.   
					■ The meanings of the symbols used in this manual are as shown below.   
					Be sure not to do.   
					Be sure to follow the instruction.   
					■ Installation   
					Do not use damaged power   
					cords, plugs, or a loose   
					socket.   
					For electrical work, contact   
					the dealer, seller, a qualified   
					electrician, or an Authorized   
					Service Center.   
					Always use the power plug   
					and socket with the ground   
					terminal.   
					• There is risk of fire or electric   
					shock.   
					• There is risk of electric shock.   
					• There is risk of fire or electric   
					shock.   
					Install the panel and the   
					cover of control box securely.   
					Do not modify or extend the   
					power cord.   
					Do not install, remove, or re-   
					install the unit by yourself   
					(customer).   
					• There is risk of fire or electric   
					shock.   
					• There is risk of fire or electric   
					shock.   
					• There is risk of fire, electric shock,   
					explosion or injury.   
					Owner’s Manual 3   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Safety Precautions   
					Be cautious when unpacking   
					and installing the product.   
					For installation, always   
					contact the dealer or an   
					Authorized Service Center.   
					Do not install the product on   
					a defective installation stand.   
					• Shape edges could cause injury.   
					Be especially careful of the sharp   
					edges.   
					• There is risk of fire, electric shock,   
					explosion, or injury.   
					• It may cause injury, accident, or   
					damage to the product.   
					Be sure the installation area   
					does not deteriorate with age.   
					Install the indoor unit on the   
					wall where the height from   
					the floors more then 8ft(2.4m)   
					Do not handle the pipe by   
					yourself(Costomer)   
					• If the base collapses, the air   
					conditioner could fall with it,   
					causing property damage, product   
					failure, and personal injury.   
					• There are sharp moving parts that   
					could cause personal injury.   
					• High-Pressure refrigent may cause   
					personal injury.   
					8ft(2.4m)   
					■ Operation   
					Use a dedicated outlet for this   
					appliance.   
					Grasp the plug to remove the   
					cord from the outlet. Do not   
					touch it with wet hands.   
					Do not allow water to run   
					into electric part.   
					• There is risk of fire or electric   
					shock.   
					• There is risk of fire or electric   
					shock.   
					• There is risk of fire, failure of   
					the product, and/or electric   
					shock.   
					4 Room Air Conditioner   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Safety Precautions   
					Do not place a heater or other   
					appliances near the power   
					cable.   
					Do not let the air conditioner   
					run for a long time when the   
					humidity is very high and a   
					door or a window is left open.   
					Do not store of use   
					flammable gas or   
					combustibles near the air   
					conditioner.   
					• 
					There is risk of fire, failure of the   
					product, and/or electric shock.   
					• Moisture may condense and wet or   
					damage furnishings.   
					• There is risk of fire or product   
					failure.   
					Do not use the product in a   
					tightly closed space for a   
					long time.   
					When flammable gas leaks, turn off   
					the gas and open a window for   
					ventilation before turning the   
					product on. Do not use the   
					Unplug the unit if strange   
					sounds odors or smoke   
					comes from it.   
					telephone or turn switches on or off.   
					• Oxygen deficiency could occur.   
					• 
					There is risk of fire, Product faiure,   
					and/or electric shock.   
					• There is risk of explosion or fire.   
					• 
					Some ventilation by opening window   
					is necessary for the fresh air   
					Stop operation and close any   
					window in storm or hurricane   
					before the hurricane arrives.   
					Do not open the inlet grill of   
					the product during operation.   
					(Do not touch the   
					electrostatic filter, if the unit   
					is so equipped.)   
					When the product is soaked   
					(flooded or submerged),   
					contact an Authorized   
					Service Center.   
					• There is risk of property damage,   
					failure of product, or electric   
					shock.   
					• There is risk of physical injury,   
					electric shock, or product.   
					• There is risk of electrical shock.   
					Owner’s Manual 5   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Safety Precautions   
					Ventilate the product from   
					time to time when operating it   
					together with a stove, etc.   
					Unplug the appliance before   
					performing cleaning or   
					maintenance.   
					When the product is not be   
					used for a long time   
					disconnect the power supply   
					plug or turn off the breaker.   
					• There is risk of fire or electrical   
					shock.   
					• There is risk of product damage or   
					failure, or unintended operation.   
					• There is risk of electric shock.   
					■ Installation   
					Take care to ensure that   
					nobody could step on or fall   
					onto the outdoor unit.   
					Do not insert hands or other   
					objects through the air inlet   
					or outlet while the air   
					Always check for   
					gas(refrigerant) leakage after   
					installation or repair of   
					product.   
					conditioner is plugged in.   
					• There could result in personal   
					injury and product damage.   
					• There are sharp and moving parts   
					that could cause personal injury.   
					• Low refrigerant levels may cause   
					product failure.   
					Install the drain hose to   
					ensure that water is drained   
					away properly.   
					Keep level even when   
					installing the product.   
					Do not install the product   
					where the noise or hot air   
					from the outdoor unit could   
					damage the neighborhoods.   
					• A bad connection may cause   
					water leakage.   
					• To avoid vibration or water   
					leakage.   
					• It may cause a problem for your   
					neighbors.   
					90˚   
					6 Room Air Conditioner   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Safety Precautions   
					■ Operation   
					Use two or more people to lift   
					and transport the air   
					conditioner.   
					Do not install the product   
					where it will be exposed to   
					sea wind (salt spray) directly.   
					Do not direct airflow at room   
					occupants.   
					• Avoid personal injury.   
					• It may cause corrosion in the   
					product. Corrosion, particularly on   
					the condenser and evaporator fins,   
					could cause product malfunction   
					or inefficient operation.   
					• This could damage your health.   
					Do not use the product for   
					special purposes, such as   
					preserving foods, works of art,   
					etc. It is a consumer air   
					Do not block the inlet or   
					outlet of air flow.   
					Use a soft cloth to clean.   
					Do not use harsh detergents,   
					solvents, etc.   
					conditioner, not a precision   
					refrigeration system.   
					• There is risk of damage or loss of   
					property.   
					• There is risk of fire, electric shock   
					or damage to the plastic parts of   
					the product.   
					• It may cause product failure.   
					Do not touch the metal parts   
					of the product when   
					removing the air filter. They   
					are very sharp!   
					Do not step on or put   
					anything on the product.   
					(outdoor unit)   
					Always insert the filter   
					securely. Clean the filter   
					every two weeks or more   
					often if necessary.   
					• There is risk of personal injury and   
					failure of product.   
					• A dirty filter reduces the efficiency   
					of the air conditioner and could   
					cause product malfunction or   
					damage.   
					• There is risk of personal injury.   
					Owner’s Manual 7   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Safety Precautions   
					Do not drink the water   
					drained from the unit.   
					Use a firm stool or ladder   
					when cleaning or maintaining   
					the air conditioner.   
					Replace all the batteries in   
					the remote.   
					• It is not sanitary and could cause   
					serious health issues.   
					• There is risk of fire or explosion.   
					• Be careful and avoid personal   
					injury.   
					I Disuse   
					Do not recharge or   
					disassemble the batteries. Do   
					not dispose of batteries in a   
					fire.   
					If the liquid from the batteries   
					gets onto your skin or clothes,   
					wash it well with clean water.   
					Do not use the remote if the   
					batteries have leaked.   
					If you eat the liquid from the   
					batteries, brush your teeth and   
					see doctor. Do not use the   
					remote if the batteries have   
					leaked.   
					• They may burn or explode.   
					• The chemicals in batteries could   
					cause burns or other health   
					hazards.   
					• The chemicals in batteries could   
					cause burns or other health   
					hazards.   
					8 Room Air Conditioner   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Prior to operation   
					Prior To Operation   
					Preparing For Operation   
					1. Contact an installation specialist for installation.   
					2. Plug in the power plug properly.   
					3. Use a dedicated circuit.   
					4. Do not use an extension cord.   
					5. Do not start/stop operation by plugging/unplugging the power cord.   
					6. If the cord/plug is damaged, ony replace it with an authorized replacement part.   
					Usage   
					1. Being exposed to direct airflow for a long time may be hazardous to your health. Do not expose   
					occupants, pets, or plants to direct airflow for a long time.   
					2. Ventilate the room when the air conditioner is used with other heating devices. Otherwise the oxygen   
					supply may be inadequate.   
					3. Do not use this air conditioner for non-specified special purpose (e.g. preserving precision devices, food,   
					pets, plants, or art objects). Such use may damage your properties.   
					Cleaning And Maintenance   
					1. Do not touch the metal parts of the unit when removing the filter. Injury can occur.   
					2. Do not use water to clean inside the air conditioner. Exposure to water can destroy the insulation,   
					leading to electric shock.   
					3. When cleaning the unit, first make sure that the power and breaker are turned off. The fan rotates at a   
					very high speed during operation. There is a possibility of injury if the unit power is accidently turned on   
					while the interior of the unit is being cleaned.   
					Service   
					For repair and maintenance, contact your authorized service dealer.   
					Owner’s Manual 9   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Introduction   
					Introduction   
					Symbols Used In This Manual   
					This symbol alerts you to the risk of electric shock.   
					This symbol alerts you to hazards that may cause harm to the   
					air conditioner.   
					This symbol indicates special notes.   
					NOTICE   
					Features   
					• This appliance should be installed in accordance with national wiring regulations. This guide acts   
					as a guide to help to explain product features.   
					Indoor   
					Air Inlet   
					Air Filter   
					Front Panel   
					Signal Receptor   
					Outdoor   
					(Rear)   
					(Side)   
					Air intake   
					vents   
					Piping   
					Air outlet   
					vents   
					10 Room Air Conditioner   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Electrical Safety   
					Electrical Safety   
					• This appliance must be properly grounded.   
					To minimize the risk of electric shock, you must alway plug into a grounded oulet   
					• Do not cut or remove the grounding prong from the power plug.   
					• Attaching the adapter ground terminal to the wall receptacle cover screw does   
					not ground the appliance unless the cover screw is metal and not insulated, and   
					the wall receptacle is grounded through the house wiring.   
					• If you have any doubt whether the air conditioner is properly grounded, have the   
					wall receptacle and circuit checked by a qualified electrician.   
					Owner’s Manual 11   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Operating Instruction   
					Operating Instruction   
					How To Insert The Batteries   
					Remove the battery cover by pulling it according to   
					the arrow direction.   
					Insert new batteries making sure that the (+) and (-)   
					of battery are installed correctly.   
					Reattach the cover by sliding it back into position.   
					Use 2 AAA(1.5volt) batteries.   
					Do not use rechargeable batteries.   
					NOTICE   
					Storage And Tips For Using The Remote Controler   
					• The remote controler may be stored by mounting it on   
					a wall.   
					• To operate the room air conditioner, aim the remote   
					control at the signal receptor.   
					Signal Receptor   
					Receives the signals from the remote control.(Signal receiving sound: two short beeps or one long beep.)   
					Operation Indication Lamps   
					On/Off   
					: Lights up during the system operation, error   
					code and auto restart setting.   
					Sleep mode : Lights up during sleep mode auto operation.   
					Plasma   
					Timer   
					: The function illustrates its dynamic mode by   
					using a multiple lighting system.   
					: Lights up during timer operation.   
					Defrost mode : Lights up during defrost mode or *hot start   
					operation (Heat pump model only)   
					: Lights up during outdoor unit operation.   
					(Cooling model only)   
					Outdoor unit   
					operation   
					OUT   
					DOOR   
					Operation indicating   
					lamps   
					Power Display : Indicates the setting temperature and operation   
					mode.   
					12 Room Air Conditioner   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Operating Instruction   
					Remote Control Operations   
					1. START/STOP BUTTON   
					Controls   
					Operation starts when this button is pressed   
					and stops when the button is pressed again.   
					Signal transmitter   
					2. OPERATION MODE SELECTION BUTTON   
					Used to select the operation mode.   
					3. ROOM TEMPERATURE SETTING   
					BUTTONS   
					Used to select the room temperature.   
					4. INDOOR FAN SPEED SELECTOR   
					Used to select fan speed in four steps   
					low, medium, high and CHAOS.   
					5. JET COOL   
					Used to start or stop the speed cooling.(speed   
					cooling operates super high fan speed in   
					cooling mode.)   
					5 
					6 
					1 
					3 
					6. CHAOS SWING BUTTON   
					Used to stop or start louver movement and   
					set the desired up/down airflow direction.   
					7. ON/OFF TIMER BUTTONS   
					Used to set the time of starting and stopping   
					operation. (See page 22)   
					4 
					10   
					2 
					7 
					CANCEL   
					8. TIME SETTING BUTTONS   
					Used to adjust the time. (See page 22)   
					9 
					ON   
					OFF   
					SET   
					AUTO CLEAN   
					12   
					11   
					8 
					9. TIMER SET/CANCEL BUTTON   
					Used to set the timer when the desired time   
					is obtained and to cancel the Timer   
					operation. (See page 22)   
					17   
					18   
					14   
					16   
					13   
					15   
					10. SLEEP MODE AUTO BUTTON   
					Used to set Sleep Mode Auto operation.   
					(See page 22)   
					11. AIR CIRCULATION BUTTON   
					Used to circulate the room air without   
					cooling or heating. (See page 23)   
					Flip-up door   
					(opened)   
					12. ROOM TEMPERATURE CHECKING   
					BUTTON   
					Used to check the room temperature.   
					Operation Mode   
					13. NEO PLASMA(OPTIONAL)   
					Used to start or stop the plasma-   
					purification function. (See page 20)   
					Cooling Operation   
					14. HORIZONTAL AIRFLOW DIRECTION   
					CONTROL BUTTON (OPTIONAL)   
					Used to set the desired horizontal airflow   
					direction.   
					Auto Operation or Auto Changeover   
					Healthy Dehumidification Operation   
					15. RESET BUTTON   
					Used prior to resetting time.   
					16. 2nd F Button   
					Heating Operation   
					Used prior to using modes printed in blue   
					at the bottom of buttons. (See page 21)   
					• 
					Cooling Model( ), Heat Pump Model(   
					) 
					17. AUTO CLEAN (OPTIONAL)   
					Used to set Auto Clean mode.   
					18. ˚C TO ˚F SWITCHING BUTTON   
					Used to switch temperature reading from   
					Centigrade to Fahrenheit.   
					Owner’s Manual 13   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Operating Instruction   
					Cooling operation   
					Press the Start/Stop button.   
					The unit will respond with   
					a beep.   
					1 
					2 
					Open the door of the remote controller. To select Cooling   
					Operation, press the Operation Mode Selection button.   
					Each time the button is pressed, the operation mode is   
					shifted in the direction of the arrow.   
					Cooling   
					Auto   
					Changeover   
					Healthy   
					Dehumidification   
					Heating   
					(Heat pump model only)   
					Close the door of the remote controller. Set the temperature   
					lower than the room temperature. The temperature can be   
					set within a range of 18°C~30°C(64°F~86°F) at intervals of   
					1°C(2°F).   
					3 
					4 
					ON   
					To raise the temperature   
					To lower the temperature   
					Set the fan speed again with the door   
					of the remote controller still closed.   
					You can select the fan speed in four   
					steps-low, medium, high and CHAOS.   
					Each time the button is pressed, the   
					fan speed mode is shifted.   
					Gentle Breeze by the CHAOS logic   
					■ For fresher feeling, press the Indoor fan speed selector and set to CHAOS mode. In this mode, the wind   
					blows like a natural breeze by automatically changing fan speed according to the CHAOS logic.   
					14 Room Air Conditioner   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Operating Instruction   
					Auto operation (Optional)   
					Press the Start/Stop button.   
					The unit will respond with   
					a beep.   
					1 
					Open the door of the remote controller. To select Auto   
					Operation, press the operation mode selection button.   
					Each time the button is pressed, the operation mode is   
					shifted in the direction of the arrow.   
					2 
					3 
					Cooling   
					Auto   
					Healthy   
					Dehumidification   
					Heating   
					(Heat pump model only)   
					The temperature and fan speed are automatically set by the   
					electronic controls based on the actual room temperature. If   
					you want to change the set temperature, press the Room   
					Temperature Setting buttons. The cooler or warmer you feel,   
					the more times (up to two times) you should press the button.   
					The set temperature will be changed automatically.   
					ON   
					To raise the temperature   
					To lower the temperature   
					During Auto Operation   
					■ You cannot control the indoor fan speed. It has already been set by the Fuzzy rule.   
					■ If the system is not operating as desired, manually switch to another mode. The system will not   
					automatically switch from the cooling mode to the heating mode, or from heating mode to cooling   
					mode, it must be done by manually resetting.   
					■ During Auto Operation, pressing the CHAOS swing button makes the horizontal louvers swing up and   
					down automatically. If you want to stop auto-swing, press the CHAOS swing button again.   
					Owner’s Manual 15   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Operating Instruction   
					Auto changeover operation(Optional)   
					Press the Start/Stop button.   
					The unit will respond with   
					a beep.   
					1 
					Open the door of the remote controller. To select Auto Changeover   
					Operation, press the Operation Mode Selection button.   
					Each time the button is pressed, the operation mode is shifted in the   
					direction of the arrow.   
					2 
					Auto   
					Changeover   
					Cooling   
					Healthy   
					Dehumidification   
					Heating   
					(Heat pump model only)   
					Close the door of the remote controller. Set the temperature   
					lower than the room temperature. The temperature can be   
					set within a range of 18°C~30°C(64°F~86°F) at intervals of   
					1°C(2°F).   
					3 
					4 
					To raise the temperature   
					ON   
					To lower the temperature   
					Set the fan speed again with the door   
					of the remote controller still closed.   
					You can select the fan speed in four   
					steps-low, medium, high and CHAOS.   
					Each time the button is pressed, the   
					fan speed mode is shifted.   
					During Auto Changeover Operation   
					The air conditioner changes the operation mode automatically to keep indoor temperature. When room   
					temperature varies over ±2°C from the set temperature, air conditioner keeps the room temperature   
					within ±2°C of the set temperature by auto changeover mode.   
					16 Room Air Conditioner   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Operating Instruction   
					Healthy dehumidification operation   
					Press the Start/Stop button.   
					The unit will respond with   
					a beep.   
					1 
					2 
					Open the door of the remote controller. To select Healthy   
					Dehumidification Operation, press the Operation Mode   
					Selection button.   
					Each time the button is pressed, the operation mode is   
					shifted in the direction of the arrow.   
					Auto   
					Changeover   
					Cooling   
					Healthy   
					Heating   
					Dehumidification (Heat pump model only)   
					Set the fan speed again with the door   
					of the remote controller still closed.   
					You can select the fan speed in four   
					steps-low, medium, high, or CHAOS.   
					Each time the button is pressed, the   
					fan speed mode is shifted.   
					3 
					ON   
					Gentle Breeze by the CHAOS logic   
					■ For fresher feeling, press the Indoor Fan Speed Selector and set   
					to CHAOS mode. In this mode, the wind blows like a natural   
					breeze by automatically changing fan speed according to the   
					CHAOS logic.   
					During Healthy Dehumidification Operation   
					■ If you select the dehumidification mode on the operation selection button, the product starts to run the   
					dehumidification function. It automatically sets the room temp. and airflow volume to the best condition   
					for dehumidification, based on the sensed current room temp.   
					In this case, however, the setting temperature. is not displayed on the remote controller and you are not   
					able to control the room temperature. either.   
					■ During the healthy dehumidification function, the airflow volume is automatically set according to the   
					optimization algorithm responding to the current room temp. status, so the room condition is kept   
					healthy and comfortable even in the very humid season.   
					Owner’s Manual 17   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Operating Instruction   
					Heating operation (Heat pump model only)   
					Press the Start/Stop button.   
					The unit will respond with   
					a beep.   
					1 
					2 
					Open the door of the remote controller. To select Heating   
					Operation, press the Operation Mode Selection button.   
					Each time the button is pressed, the operation mode is   
					shifted in the direction of the arrow.   
					Auto   
					Changeover   
					Cooling   
					Healthy   
					Heating   
					Dehumidification (Heat pump model only)   
					Close the door of the remote controller.   
					Set the temperature higher than the room temperature.   
					The temperature can be set within a range of   
					16°C~30°C(60°F~86°F) at intervals of 1°C(2°F).   
					To raise the temperature   
					3 
					4 
					ON   
					To lower the temperature   
					Set the fan speed again with the door of the   
					remote controller still closed. You can   
					select the fan speed in four steps–low,   
					medium, high and CHAOS. Each time the   
					button is pressed, the fan speed mode is   
					shifted.   
					Gentle Breeze by the CHAOS logic   
					■ For fresher feeling, press the Indoor Fan Speed Selector and set to CHAOS mode. In this mode, the   
					wind blows like a natural breeze by automatically changing fan speed according to the CHAOS logic.   
					18 Room Air Conditioner   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Operating Instruction   
					Jet cool operation   
					Press the Start/Stop button.   
					The unit will respond with   
					a beep.   
					1 
					2 
					3 
					Press the Jet Cool button to operate   
					the speed cooling mode and the unit   
					will operate at super high fan speed   
					on cooling mode for 30 minutes.   
					To cancel the Jet Cool mode, press the Jet Cool button, the   
					fan speed button or the room temperature setting button   
					again and the unit will operate at high fan speed on cooling   
					mode.   
					or   
					or   
					NOTICE   
					■ During the JET COOL function at any moment, the A/C starts to blow the cool air at extremely   
					high speed for 30 minutes setting the room temperature. automatically to 18°C. It is especially   
					used to cool the room temperature. quickly in a hot summer.   
					In heat pump mode or auto changeover mode, however, the JET COOL function is not available.   
					■■In order to return to the normal cooling mode from the JET COOL mode, just press the operation   
					mode selection button, airflow volume selection, temperature. setting button or the JET COOL   
					button again.   
					Owner’s Manual 19   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Operating Instruction   
					NEO PLASMA purification operation(Optional)   
					Press the Start/Stop button.   
					The unit will respond with a   
					beep.   
					1 
					2 
					Open the door of the remote   
					controller. Press the PLASMA   
					button.   
					Operation will start when the button   
					is pressed and stop when the button   
					is pressed again.   
					Set the fan speed again with the door of the remote   
					controller closed. You can select the fan speed in four   
					steps-low, medium, high or CHAOS.   
					Each time the button is pressed, the fan   
					speed mode is shifted.   
					3 
					■ Air purifying operation (NEO PLASMA) can be   
					with cooling, Heating or any other operations.   
					NEO PLASMA Air Purifying Operation only   
					If you press the only PLASMA button, only   
					PLASMA purification function operates.   
					Then, fan speed is low. You can select the fan   
					speed in four steps-low, medium, high or   
					CHAOS.   
					Each time the Indoor Fan Speed Selector   
					button is pressed, the fan speed mode is   
					shifted.   
					20 Room Air Conditioner   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Operating Instruction   
					2nd F operation   
					Press the Start/Stop button.   
					The unit will respond with   
					a beep.   
					1 
					2 
					Open the door of the remote controller and press the 2nd   
					Function button to operate functions printed blue color under   
					buttons.   
					(Check the indication of 2nd function on the display of the   
					remote controller.)   
					CANCEL   
					ON   
					OFF   
					SET   
					AUTO CLEAN   
					2nd function disappears in a short time automatically or when   
					the button is pressed again.   
					3 
					For more details, refer to functions next pages.   
					Owner’s Manual 21   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Operating Instruction   
					Additional Features   
					Sleep mode   
					1. Press the Sleep Mode Auto button to set the time you want the unit to stop automatically.   
					2. The Timer is programmed in one-hour increments by pressing the Sleep Mode Auto button 1 to 7 times. The   
					sleep mode is available for 1 to 7 times. To alter the time period in steps of 1 hour, press the Sleep Mode   
					Button while aiming at air conditioner.   
					3. Make sure the Sleep Mode Auto LED lights up .   
					To cancel the Sleep Mode, press the sleep Mode Auto button several times until the star(   
					disappears from the operation display.   
					) 
					NOTICE   
					The Sleep Mode will be operated at slow fan speed (cooling) or medium fan speed (heat pump only) for   
					a comfortable sleep.   
					In cooling mode or healthy dehumidification mode:   
					The setting temperature will automatically rise by 1°C(2°F) over the next 30 minutes and by 2°C(4°F) in 1 hour for a   
					comfortable sleep.   
					Setting the time   
					1. Time can be set only when you press the Reset button. When you replace the batteries,   
					you should press the reset buttons to reset the time. Press the Start/Stop button.   
					2. Press 2nd F button and check if 2nd F icon is on.   
					3. Press the Time Setting buttons until the desired time is set.   
					CANCEL   
					4. Press the Timer SET button.   
					SET   
					NOTICE   
					Check the indicator for A.M. or P.M.   
					Delay start/Pre-set stop   
					1. Make sure the time is set correctly on the display of the remote controller.   
					2. Press 2nd F button.   
					ON   
					OFF   
					3. Press the ON/OFF Timer buttons to turn Timer on or off.   
					4. Press the Time Setting buttons until the desired time is set.   
					CANCEL   
					SET   
					5. To set the selected time, press the Timer setting button aiming the remote controller at the   
					signal receptor.   
					To cancel the timer setting   
					Check if 2nd F icon is off.   
					CANCEL   
					Press the Timer Cancel button aiming the remote controller at the signal receptor.   
					SET   
					(The timer lamp on the air conditioner and the display will go out.)   
					NOTICE   
					with the unit running   
					Select one of the following four types of operation.   
					Delay OFF Timer   
					Delay ON Timer   
					Delay OFF and ON Timer Delay ON and OFF Timer   
					22 Room Air Conditioner   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Operating Instruction   
					Vertical Airflow Direction Control   
					The up/down airflow (Vertical Airflow) can be   
					adjusted by using the remote control.   
					NOTICE   
					■■If you press the CHAOS swing button, the vertical   
					airflow direction is changed automatically based on the   
					CHAOS algorithm to distribute the air in the room   
					evenly and at the same time to make the human body   
					feel most comfortable, as if enjoying a natural breeze.   
					■■Always use the remote control to adjust the up/down   
					airflow direction. Manually moving the vertical airflow   
					direction louver by hand could damage the air   
					conditioner.   
					1. Press the Start/Stop button to start the unit.   
					■■When the unit is shut off, the up/down airflow direction   
					louver will close the air outlet vent of the system.   
					2.Open the door on the remote control.   
					Press Chaos Swing button and the louvers will   
					swing up and down. Press the Chaos Swing   
					button again to set the vertical louver at the   
					desired airflow direction.   
					To adjust left/right(Horizontal Airflow) direction   
					Ensure unit is turned off before   
					adjusting the horizontal airflow   
					direction control.   
					Carefully open vertical louver to   
					allow access to the horizontal airflow direction.   
					Adjust the left/right airflow direction by hand.   
					Air Circulation Mode   
					Circulates the room air without cooling or heating.   
					1. Press the Start/Stop button. the unit will respond with a beep.   
					2. Open the door on the remote control. Press the Air Circulation button. Close the door on the   
					remote control. Now each time that you press the Indoor Fan Speed Selector, the fan speed is   
					shifted from low to CHAOS and back to low again.   
					CHAOS Air   
					Fan speed is on low. Fan speed is on medium. Fan speed is on high.   
					NOTICE   
					■ CHAOS Air economizes power consumption and prevents overcooling. The fan speed is automatically   
					changed from high to low or vice versa, depending on the ambient temperature.   
					Owner’s Manual 23   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Operating Instruction   
					Auto clean (Optional)   
					1. Whenever you press the AUTO CLEAN button, Auto Clean Function will be   
					reserved and cancelled.   
					AUTO CLEAN   
					2. Auto Clean function works before and after cooling or dehumidification mode.   
					For details, refer to the below points.   
					3. When the unit is started after the reservation of Auto Clean ,the Cool Start   
					function operates and indoor Fan is started after 20 seconds.   
					4. When you press Start/Stop button to turn off the unit after the you have reserved   
					Auto Clean function, the air-conditioner circulates the indoor air in the Auto   
					Clean mode with no more Cooling or Dehumidification operation. It lasts for 30   
					minutes.   
					5. If you press the AUTO CLEAN button again during the product operation , Auto   
					Clean function will be cancelled.   
					NOTICE   
					■ During Auto Clean function, moistures left in indoor units after Cooling Operation or Healthy   
					Dehumidification Operation can be removed.   
					■ During Auto Clean function, only Start/Stop button, Plasma button and AUTO CLEAN button are   
					available.   
					Forced operation   
					Operation procedures when the remote control can't be used.   
					The operation will be started if the ON/OFF button is pressed.   
					If you want to stop operation, re-press the button.   
					ON/OFF   
					button   
					Heat pump Model   
					Cooling Model   
					Room Temp. ≥ 24°C(75.2   
					°F)   
					21°C(69.8°F) ≤ Room Temp. < 24°C(75.2°F)   
					Healthy Dehumidification   
					High   
					Room Temp. < 21°C(69.8   
					°F)   
					Operating mode   
					Cooling   
					High   
					Cooling   
					High   
					Heating   
					High   
					Indoor FAN Speed   
					Setting Temperature 22°C(71.6°F)   
					22°C(71.6°F)   
					23°C(73.4°F)   
					24°C(75.2°F)   
					Test operation   
					During the TEST OPERATION, the unit operates in cooling mode at high speed fan, regardless of room   
					temperature and resets in 18 minutes.   
					During test operation, if remote controller signal is received, the unit operates as remote controller sets.   
					If you want to use this operation, Press and hold the ON/OFF button for 3~5 seconds, then the buzzer sound   
					1 "beep".   
					If you want to stop the operation, re-press the button.   
					24 Room Air Conditioner   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Operating Instruction   
					Auto restart   
					In case the power comes on again after a power failure, Auto Restarting Operation is the function to operate   
					procedures automatically to the previous operating conditions.   
					So there is no need of activating this function by pressing any key or button.   
					In the initial mode, the fan operates at a low speed and the compressor starts 2.5~3 minutes later.   
					As the compressor starts, the fan speed also resumes its previous setting mode.   
					Helpful information   
					Fan speed and cooling capacity.   
					The cooling capacity indicated in the specification is the value   
					when the fan speed is set to high, and the capacity will be lower   
					at low or medium fan speed.   
					High fan speed is recommended when you wish to cool the room   
					quickly.   
					High   
					Speed   
					NOTICE   
					Auto restart function has set enable as factory default.   
					But customer can set up by following this instruction.   
					To disable function   
					- Press and hold the ON/OFF button for 6 seconds, then the buzzer sound 2 "beep" and the indicator lamp (1)   
					blinks 4 times.   
					To enable function   
					- Press and hold the ON/OFF button for 6 seconds, then the buzzer sound 2 "beep" and the indicator lamp (1)   
					brights 4 times.   
					Owner’s Manual 25   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Maintenance and Service   
					Maintenance And Service   
					Before performing any maintenance, turn off the main power to the system.   
					Indoor Unit   
					Grille, Case, and Remote Control   
					Turn the system off before cleaning. To clean, wipe with a soft, dry   
					cloth. Do not use bleach or abrasives.   
					NOTICE   
					Air inlet vent Air outlet vent   
					Vertical louver   
					Air filters   
					Supply power must be disconnected before cleaning the indoor unit.   
					(behind front panel)   
					Horizontal louver   
					Air filters   
					The air filters behind the front grille should be checked and   
					cleaned once in every 2 weeks or more often if neccessary.   
					1. Open the front panel as shown.   
					2. Pull the filter tab slightly forward to remove the filter.   
					3. Clean the filter with a vacuum cleaner or warm, soapy water.   
					• If dirt is conspicuous, wash with a solution of   
					detergent in lukewarm water.   
					• If hot water (40°C(104°F) or more) is used, it may be   
					deformed.   
					4. After washing with water, dry well in the shade.   
					5. Re-install the air filter.   
					NEO PLASMA filter (Optional)   
					The NEO PLASMA filter behind the air filters should be   
					checked and cleaned once in every 3 months or more often if   
					necessary.   
					1. After removing the air filters, pull slightly forward to remove   
					the NEO PLASMA filter.   
					2. Clean NEO PLASMA filter with the vacuum cleaner.   
					If it is very dirty, wash it with water.   
					3. Note the cuts of electric discharge lines.   
					4. Re-install the NEO PLASMA filter to the original position.   
					TRIPLE DEODORIZER filter (Optional)   
					TRIPLE   
					DEODORIZING   
					Filter   
					1. After removing the air filters, pull slightly forward to remove   
					the TRIPLE DEODORIZER filter.   
					2. Dry in the sunlight for two hours.   
					NEO PLASMA   
					Filter   
					3. Re-install the TRIPLE DEODORIZER filter to the original   
					position.   
					Don't touch this NEO PLASMA Filter within 10 seconds after opening he inlet grille,   
					it may cause an electric shock.   
					Never use any of the followings:   
					• Water hotter than 40°C(104°F)   
					Could cause deformation and/or discoloration.   
					P 
					o 
					w 
					d 
					e 
					r 
					G 
					a 
					e 
					n 
					s 
					o 
					l 
					i 
					• Volatile substances   
					Could damage the surfaces of the air conditioner.   
					26 Room Air Conditioner   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Maintenance and Service   
					Outdoor Unit   
					The heat exchanger coils and panel vents of   
					the outdoor unit should be checked regularly.   
					If clogged with dirt or soot, the heat exchanger   
					and panel vents may be professionally steam cleaned.   
					(Rear)   
					(Side)   
					Air intake   
					vents   
					Piping   
					Air outlet   
					vents   
					NOTICE   
					Dirty or clogged coils will reduce the   
					operating efficiency of the system and cause   
					higher operating costs.   
					Common Problems And Solutions   
					Before calling for service   
					If you have problems with your air conditioner, read the following information and try to solve the problem. If you   
					cannot find a solution, turn off the air conditioner and contact your dealer.   
					Air conditioner does not operate   
					1. Ensure that the air conditioner is plugged into a proper outlet.   
					2. Check the fuse or circuit breaker.   
					3. Check whether the voltage is unusually high or low.   
					Air does not feel cold enough on the cooling setting   
					1. Ensure that the temperature settings are correct.   
					2. Check to see if the air filter is clogged with dust. If so, replace the filter.   
					3. Ensure that the air flow from the outside is not obstructed and that there is a clearance of over 20" between the   
					back of the air conditioner and the wall or fence behind it.   
					4. Close all doors and windows and check for any source of heat in the room.   
					Before calling for service, please review the following list of common problems and solutions.   
					The air conditioner is operating normally when:   
					• You hear a pinging noise. This is caused by water being picked up by the fan on rainy days or in highly humid   
					conditions. This feature is designed to help remove moisture in the air and improve cooling efficiency.   
					• You see water dripping from the rear of the unit. Water may be collected in the base pan in highly humid   
					conditions or on rainy days. This water overflows and drips from the rear of the unit.   
					• You hear the fan running while the compressor is silent. This is a normal operational feature.   
					Owner’s Manual 27   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Maintenance and Service   
					Troubleshooting   
					The air conditioner may be operating abnormally when:   
					Problem   
					Possible Causes   
					What To Do   
					■ The air conditioner is   
					unplugged.   
					• Make sure the air conditioner plug is   
					pushed completely into the outlet.   
					■ The fuse is blown/circuit   
					breaker is tripped.   
					• Check the house fuse/circuit breaker   
					box and replace the fuse or reset the   
					breaker.   
					Air   
					conditioner   
					does not start   
					■ Power failure.   
					• If power failure occurs, turn the mode   
					control to Off.   
					When power is restored, wait 3   
					minutes to restart the air conditioner   
					to prevent tripping of the compressor   
					overload.   
					■ Airflow is restricted.   
					■ The air filter is dirty.   
					• Make sure there are no curtains,   
					blinds, or furniture blocking the front of   
					the air conditioner.   
					• Clean the filter at least every 2 weeks.   
					See the care and Maintenance   
					section.   
					Air   
					conditioner   
					does not cool   
					as it should   
					■ The room may have been   
					hot.   
					• When the air conditioner is first turned   
					on, you need to allow time for the   
					room to cool down.   
					■ Cold air is escaping.   
					• Check for open furnace floor registers   
					and cold air returns.   
					■ Cooling coils have iced up.   
					• See Air Conditioner Freezing Up   
					below.   
					
					28 Room Air Conditioner   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				P/No.: 3828A20434H   
					Printed in Korea   
					After reading this manual, keep it in a place easily accessible to the user for future reference.   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				 |