Gianni Industries Welding System DG 600 User Manual

DG-600 Standalone Proximity Reader  
Operation User's Manual  
I.  
Product Characteristic:  
DG-600 has a 600 cards and PIN codes capacity and a reading time of 0.5-second max.  
Transmitted to the host with extended Wiegand format auxiliary reader.  
The Unit will operate with card only, PIN or card, PIN + card.  
The logical memory does not allow duplicate cards to be programmed.  
The host unit will lockout for 60 seconds if 5 incorrect password attempts are entered.  
Beeper sound gives positive signal of all keypad activations.  
Build in tamper switch that turns on alarm relay to ensure vandal proof operation.  
Non-volatile memory stores all programmed information for at least 10 years, even in the  
event of total power failure.  
Removable memory chip in the main control module allows on site replacement in the  
event of break down.  
Fully Programmable via keypad and master code  
Copyright Gianni Industries, Inc. All Rights Reserved.  
P-MU-DG600 Ver. B Publish:2004.08.27  
Page: 1/ 6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
III.  
The indicator signal chart:  
Sound and LED indicator:  
Mode  
Signal  
Condition  
Power on, Stand-by  
Yellow LED  
(Flashing slowly)  
Green LED  
Red LED  
User Signals  
Valid entry, lock relay active  
Warning, Invalid Card or code, Tamper  
LED  
signal  
Yellow LED  
Programming mode entered  
Yellow LED  
(Flashing)  
Card has been read, awaiting input of PIN  
codes  
Programming  
Signals  
Green LED  
Red LED  
Slot Position ready to store card  
Memory slot already has a card registered  
Card presentedAny key pressed  
Invalid card Data computing error  
1 Beep  
User Signals  
4 Beeps  
Sound  
signal  
The input data is correct Enters or Exit  
Programming mode  
Input mistake, or other operation mistakes,  
duplicate card  
1 Beep  
Programming  
Signals  
4 Beeps  
Default Settings:  
Access Mode Read Card only (00)  
All bits44-bit or 26~37-bit)  
Format  
Card register None  
Master Codes 12345 (5 digits)  
(All) Alarm function Defeat able (00)  
Relocking timer 5 seconds  
Pressed key delay time (Time Out) 5 seconds  
Waiting input PIN codes time 5 seconds  
Setting mode delay time 25 seconds  
Terminal connections:  
CN1 Contacts on block for the system  
CN2 Contacts on block for auxiliary reader  
12 + 8.5 ~ 16 Vdc  
12 + 8.5 ~ 16 Vdc  
GND Power ground  
GND Power ground  
V
D
V
DATA1 Wiegand Data 1  
Electrified lock  
D1  
Electrified lock, Alarm Common  
(COM)  
C
D0 DATA0 Wiegand Data 0  
A
E
B
Alarm Common  
Door reed switch  
Request-to-exit  
LED LED contact  
BEEP Beeper contact  
Copyright Gianni Industries, Inc. All Rights Reserved.  
P-MU-DG600 Ver. B Publish:2004.08.27  
Page: 3/ 6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IV. Wiring diagram:  
Fail-Safe Lock  
St 2 connect to 1-2  
Contact door switch or the  
electric lock signal output  
Fail-Secure Lock  
St 2 connect to 2-3  
Push Button  
Power supply  
(10~15Vdc)  
External relay start  
the warning system  
*Linear supply recommended  
Auxiliary Reader  
(Wiegand Format)  
Insert 2-3 position to reset  
DG-600E Jp1 leads to Wiegand 44 bits format  
Connect to 1-2;C and D contact is N.C.  
Connect to 2-3; for N.O.  
DG-600E Jp1 short-circuit to Wiegand 26 bits format  
DG-600H Jp1 leads to all Wiegand format  
Connect to 1-2;C andA contact is N.C.  
Connect to 2-3; for N.O.  
DG-600H Jp1 short-circuit to Wiegand 26 bits format  
Note:  
1. DG-600 auxiliary reader must not be further than 20 meters from the host. Also this  
reader should be nearer than 30 centimeters, to avoid disturbance. The suggested wire  
gauge is #22~26 AWG.  
2. DG-600E important instructions: At the back of the main PC board JP1 (see wiring  
diagram). The system storage card form is Wiegand 44 bits. When you have Wiegand 26  
bits auxiliary reader, please do use the solder to short JP1 to turn to Wiegand 26 bits  
(HEX) form, the auxiliary reader stores different card, this produce invalid card readings  
3. DG-600H, the card storage form is Wiegand. If short-circuits JP1 turns Wiegand 26 bits  
form, can only read Wiegand 26 bits to the system.  
4. DG-600E, DG-600H when JP1 has the change, there’s a possibility the card stored  
would be invalid. Reset to input the card.  
5. The varistor or diode must be connected across the lock terminal (electromagnet...)  
operated by the device. The vartistor controls the overload produced by the strike coil  
(EMP).  
6.  
Egresses switch is in N.O. Condition.  
7. Alarm system use (C.A. contact) start with external relay.  
8. Using a Linear supply power recommended, to prevent power reduction at the card  
reader.  
Copyright Gianni Industries, Inc. All Rights Reserved.  
P-MU-DG600 Ver. B Publish:2004.08.27  
Page: 4/ 6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
V.  
Operation Instruction  
WARNING: Please read all of operation instruction before proceeding.  
Enter Program Mode  
Enter twice the master code : (Default setting is "12345") Yellow LED will light up →  
you are now in the “Programming Mode”.  
Exiting from the Program Mode  
Press #to exit from the programming mode, or if no activation has happened  
for 25 seconds , the system will return to the user mode.  
System Setting Access Mode  
Enter the Programming Mode, Press 0+ ??」  
A. Proximity Only: For Using Card/Tag Only.  
?? = 00, setting complete.  
B. Proximity or PIN Code to open the door:  
?? = 01, setting complete.  
C. Proximity + PIN to open the door: Card followed by PIN code to enter.  
?? = 02, the setting is complete.  
Note 1: After using the proximity card the yellow LED blinks and input the PIN codes. If  
wrong PIN code is input it will automatically return to the “User Mode”.  
Note 2: 5 continuous wrong pin codes will automatically deletes the card.  
Adding and deleting cards  
Enter the Programming Mode, Press the card storage slot code000~599  
A. Green light comes on: This slot code may register the card  
I.  
Show card to readerÆYellow light blinks Æ input 5 digits PIN codes Æ Green light  
offÆ enrolled completed Ærepeat)  
II.  
Show card to readerÆ (4 audible beep) another card has already been input  
(duplicate card).  
B. Red light comes on: This slot already has a code registered  
I.  
Press 「**(deletion) Æ Green light comes on Æ Show card to reader Æ  
same as step “A-1”﹞  
II.  
Enter another slot card position.  
Note 1: Regardless of system setting access mode select, you must enter a 5-digit PIN  
codes after showing the card to complete the register program, otherwise the card  
input will not be successful.  
Note 2: The master code are not be used for PIN code.  
Relocking timer setting  
Enter the Programming Mode, Press 「*1+??」  
A. Pulse mode:?? = 01~99 seconds, 05 represents 5 seconds (An audible beep)  
indicates setting successfullyto exit from the programming mode, or program other  
operating.  
B. Latching mode:?? = 00 (An audible beep) indicates setting successfullyto exit from  
the programming mode, or program other operating.  
Note: Enter00Sets the relay to latching mode. (Correct code or card entered opens the  
relay, and the relay stays open until the correct code or card is entered again).  
Copyright Gianni Industries, Inc. All Rights Reserved.  
P-MU-DG600 Ver. B Publish:2004.08.27  
Page: 5/ 6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Alarm Function  
Enter the Programming Mode, Press 「*2+??」  
A. Alarm Setup: Input time ,??= 01~99, 05 represents 50 seconds.  
B. To turn off alarm function: Input 00」  
Example 1: Door Held Open Alarm  
If the relocking timer is set for 5 seconds, and the Alarm Setup is set for 10 seconds,  
the following will happen:  
If the door has been opened via a valid card or PIN codes, but has remained open for  
more than 15 seconds then an audible alarm will sound and the RED LED will flash and  
remain until the door has been closed correctly.  
This activation is controlled, using contacts Eand V.  
Example 2: Door Forced Alarm (same example)  
If the door is opened without the use of a valid card or PIN codes, the audible alarm will  
sound and the RED LED will flash and remain until the door has been closed correctly.  
This activation is controlled, using contacts Eand V.  
Example 3: Panel Tamper Alarm  
The main panel has a anti-tamper micro switch installed, if the main panel is opened,  
the audible alarm will sound and the RED LED will flash and remain until the panel has  
been closed correctly.  
Changing the Master codes  
Enter the Programming Mode, Press 「*3+?????the new 5 digit master code  
→(An audible beep)→enrolled completedEnter #to exit from the  
programming mode, or program other operating.  
Reset Function  
A. To Reset the master code only (Return to default setting "12345")  
Insert the jumper ST1 2-3 positionGreen LED will flashAn audible beep→  
completed Return Insert the jumper ST1 to 1-2 position  
Note: Remove jumper after Yellow LED has been flashing for 5 Seconds. If the jumper is  
NOT removed then the system will TOTALLY reset and remove all stored information  
B. Totally reset remove all stored information)  
Insert the jumper ST1 2-3 positionGreen LED will flashAn audible beepRed  
LED will flashAn audible beep, all parameters resetReturn Insert the jumper ST1  
to 1-2 position  
Copyright Gianni Industries, Inc. All Rights Reserved.  
P-MU-DG600 Ver. B Publish:2004.08.27  
Page: 6/ 6  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Echo Saw SRM 280 User Manual
Euro Pro Iron SC620 User Manual
Fedders Heat Pump CH12 User Manual
Flying Mole Stereo Amplifier CAS10 User Manual
Garmin GPS Receiver TBM850 User Manual
GE Food Processor 169141 User Manual
GE Ice Maker CLP 2001 User Manual
GE Monogram Cooktop ZGG300LBPSS User Manual
GE Oven SA304X 8 User Manual
GE Washer Washers User Manual