Figure 2. Recommended distances to  
front wall  
Figure 1. Connecting the 7050A to a pair of Genelec 1029A/2029A/2029B active monitors  
the bass level at lower frequencies and may  
cause asymmetrical spatial imaging.  
subwoofer. Place the subwoofer into the right  
end of the recess with the driver side facing  
the room. This leaves sufficient 7,5 centime-  
ters (3") of free space on the reflex port side.  
The height and depth of the recess should  
not be any bigger than what is needed to fit  
the subwoofer flush with the wall surface.  
any objects filled with liquid,  
such as vases on the  
Although the 7050A is magnetically  
shielded, it may cause colour distortion if  
placed near to very sensitive video monitors  
or computer displays. Move the subwoofer  
further away or try turning the driver side of  
the subwoofer away from the screen.  
subwoofer or near it.  
Servicing and adjustment must  
only be performed by  
qualified service personnel.  
Opening the amplifier unit is strictly  
prohibited except by qualified  
service personnel.  
Setting the input sensitivity  
Minimum clearances to walls  
or other objects  
Do not cover the driver side of the subwoofer  
or place the subwoofer so that there is less  
than 10 centimeters (4") of free space in front  
of the grille.  
The 7050A is set to the same sensitivity  
as the 1029A/2029A/2029B monitors in free  
field conditions. However, when placed near  
reflecting surfaces the sensitivity typically  
needs to be attenuated due to increased  
room loading. A typical starting point would  
be -4 dB. This is achieved by adjusting the  
rotary level control on the amplifier plate. The  
use of proper measuring equipment together  
with careful listening is highly recommended.  
The maximum attenuation is -18 dB.  
Always use a mains power  
connection with protective earth.  
Failing to do this may lead  
to personal injury.  
Warning!  
Make sure that the space underneath the  
subwoofer is clear from obstructions. Thick  
carpets may block the ventilation clearance  
needed for cooling the amplifier unit.  
The reflex port side (opposite of the con-  
nector panel side) should always have a  
clearance of at least 7,5 centimeters (3") to  
any objects to ensure proper functioning of  
the reflex port.  
This equipment is capable of delivering sound  
pressure levels in excess of 85dB, which may  
cause permanent hearing damage.  
Maintenance  
No user serviceable parts are inside the  
amplifier unit. Any maintenance of the unit  
must only be performed by qualified service  
personnel.  
Safety considerations  
Genelec 7050A subwoofer has been designed  
in accordance with international safety stand-  
ards. However, to ensure safe operation and  
maintain the unit in safe operating condition,  
the following warnings and cautions must be  
observed:  
Flush mounting the subwoofer  
Guarantee  
If the subwoofer is flush mounted into a wall  
or a cabinet, it is important to ensure ampli-  
fier cooling and unrestricted airflow from the  
reflex port. This can be done by making the  
recess 7,5 centimeters (3") wider than the  
This product is supplied with a ONE year  
guarantee against manufacturing faults or  
defects that might alter the performance of  
the unit. Refer to supplier for full sales and  
guarantee terms.  
Do not expose the subwoofer to  
water or moisture. Do not place  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7050A Operating Manual  
SYSTEM SPECIFICATIONS  
AMPLIFIER SECTION  
7050A  
7050A  
Free field frequency response  
Short term amplifier output  
power (Long term output power  
is limited by driver unit  
(+/- 3 dB)  
38 Hz…85 Hz  
Maximum short term sine wave  
SPL output averaged from  
45 to 85 Hz, measured in  
half space at 1 meter  
protection circuitry)  
70 W  
Amplifier system distortion  
at nominal output  
THD  
100 dB SPL  
105 dB SPL  
15 dB  
0.08%  
Maximum peak SPL output with  
random pink noise, measured  
in half space at 1 meter  
Mains voltage  
230 V, 115/230V or 100/200V  
according to region  
Self generated noise level in  
free field @ 1 m on axis  
(a-weighted)  
Power consumption (average)  
Idle  
Full output  
10 VA  
100 VA  
Harmonic distortion  
@ 95 dB SPL  
40 … 85 Hz  
3 %  
at @ 1 m on axis in half space  
2nd  
3rd  
2 %  
Driver, magnetically shielded  
Weight  
200 mm (8”)  
15 kg (33 lbs)  
Dimensions  
Height  
410 mm (16 1/8”)  
350 mm (13 3/4”)  
314 mm (12 3/8”)  
Width  
Depth  
INPUT SECTION  
CROSSOVER SECTION  
7050A  
7050A  
Input connector XLR female  
Subsonic filter  
pin 1  
pin 2  
pin 3  
gnd  
+
(18 dB/octave) below  
38 Hz  
85 Hz  
Crossover frequency,  
(sub/main channels)  
Input impedance  
10 kohm balanced  
Input level for 100 dB SPL  
output @ 1 m  
0…–18 dB (referenced to 1029/2029 output)  
CONTROLS  
7050A  
Input sensitivity  
0…–18 dB  
Genelec Document D0045R001. Copyright Genelec Oy 5.2002. All data subject to change without prior notice  
International enquiries:  
In the U.S. please contact  
Genelec, Inc., 7 Tech Circle  
Natick, MA 01760  
Genelec, Olvitie 5  
FIN-74100, Iisalmi, Finland  
Phone +358 17 83 881  
Fax +358 17 812 267  
Phone +1 508 652 0900  
Fax +1 508 652 0909  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Ei Electronics Smoke Alarm B16009 R0 160RC Series User Manual
Eiki Fitness Equipment LC X50 User Manual
Fellowes Chipper SB 95C User Manual
FujiFilm Film Camera AF3 177E User Manual
Fujitsu Scanner 15C User Manual
Gefen Switch EXT TV MFS User Manual
GE Microwave Oven DVM1665 User Manual
Generac Power Systems Portable Generator 004270 1 User Manual
Global Machinery Company Automobile C4500 User Manual
Global Machinery Company Saw LS750P JM User Manual