Genelec Portable Speaker 8040A User Manual

Operating Manual  
8000 Series  
Genelec 8040A and 8050A  
Monitoring Systems  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Figure 2. Location of the acoustic axis  
Cable  
Screen  
RCA  
(Source)  
XLR  
(Speaker)  
Figure 3. RCA to XLR cable  
Figure 1. Amplifier panel layout of the 8040A  
Minimum clearances  
threaded hole which can be used for secur-  
ing the loudspeaker to its base. Do not use  
this thread for mounting the loudspeaker on  
a microphone stand which has a 3/8" UNC  
thread.  
and the loudspeaker. The factory settings  
for these controls are all "OFF" to give a flat  
anechoic response.  
Sufficient cooling for the amplifier and func-  
tioning of the reflex port must be ensured if  
the loudspeaker is installed in a restricted  
space such as a cabinet, or integrated into  
a wall structure. The surroundings of the  
loudspeaker must always be open to the  
listening room with a minimum clearance of  
5 centimeters (2") behind, above and on both  
sides of the loudspeaker.The space adjacent  
to the amplifier must either be ventilated or  
sufficiently large to dissipate heat so that the  
ambient temperature does not rise above  
35 degrees Celsius (95°F).  
Bass roll-off control  
Bass roll-off (first switch group from the left)  
affects the low frequency roll-off of the loud-  
speaker and attenuates its energy output  
near the cut-off frequency. Attenuation levels  
of -2, -4 or -6 dB can be selected.  
Setting the input sensitivity  
The input sensitivity of the loudspeakers can  
be matched to the output of the mixing con-  
sole, or other source, by adjusting the input  
sensitivity control on the rear panel (see  
figure 1). A screwdriver is needed for the  
adjustment. The manufacturer’s default set-  
ting for this control is -6 dBu (fully clockwise)  
which gives an SPL of 100 dB @1m with  
-6 dBu input level.  
Desktop low frequency control  
The desktop low frequency control (fourth  
switch of first switch group from the left)  
attenuates the bass frequencies around  
160 Hz by 4 dB (see figures 8 and 10). This  
feature is designed to compensate for the  
boost often occurring at this frequency range  
when the loudspeaker is placed upon a meter  
bridge, table or similar reflective surface.  
Mounting options  
The vibration insulating Isolation Positioner/  
Decoupler™ (Iso-Pod™) table stand allows  
tilting of the loudspeaker for correct align-  
ment of the acoustic axis. The stand can be  
attached to three mounting points allowing  
vertical and symmetrical horizontal position-  
ing (see figures 1 and 4).  
Setting the tone controls  
The frequency response of the system  
may also have to be adjusted to match the  
acoustic environment. The adjustment is  
carried out by setting the three tone con-  
trol switch groups "treble tilt", "bass tilt"  
and "bass roll-off" on the rear panel of the  
amplifier. There is also a special "desktop  
low frequency" tone control which gives an  
attenuation of 4 dB at 160 Hz to compen-  
sate the effect of a mixing console, desk or  
other reflective surface between the listener  
Bass tilt control  
The bass tilt control switches (second switch  
group from the left) offer three attenuation  
levels for the bass response below 800 Hz,  
usually necessary when the loudspeak-  
ers are placed near room boundaries. The  
attenuation levels are -2 dB, -4 dB and  
-6 dB.  
Genelec 8040A and 8050A can be fitted  
to Omnimount® Series 30 (8040A) and 60  
(8050A) and König & Meyer loudspeaker  
mounts on two sets of M6x10 mm threaded  
holes on the back of the enclosure. On the  
base of the enclosure is an M10x10 mm  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Speaker Mounting Position  
Flat anechoic response  
Treble tilt  
None  
Bass tilt  
None  
Bass roll-off  
None  
Desktop LF  
None  
Free standing in a damped  
room  
None  
-2 dB  
None  
None  
Free standing in a  
reverberant room  
None  
None  
None  
-4 dB  
-2 dB  
-4 dB  
None  
None  
-4 dB  
None  
-4 dB  
None  
Near field on a reflective  
surface  
In a corner  
Figure 5. Omnimount type  
wall mount  
Figure 6. K&M type  
wall mount  
Table 1. Suggested tone control settings in some typical situations  
Figure 4. The Iso-Pod™ can also be attached to the side of the enclosure for  
horizontal mounting.  
Figure 7. Carrying bag for a pair of 8040A loudspeakers.  
5. Free flow of air behind the loudspeaker  
Treble tilt control  
fier unit. Any maintenance or repair of the  
loudspeaker should only be undertaken by  
Treble tilt (third switch group from the left)  
allows adjusting the treble response above  
5 kHz by +2, -2, or -4 dB, which can be used  
for correcting an excessively bright or dull  
sounding system.  
is necessary to maintain sufficient cooling.  
Do not obstruct airflow around the  
loudspeakers.  
qualified service personnel.  
Safety considerations  
Although the 8040A and 8050A have been  
designed in accordance with international  
safety standards, to ensure safe operation  
and to maintain the loudspeaker under safe  
operating conditions, the following warnings  
and cautions must be observed:  
WARNING!  
Genelec 8040A and 8050A loudspeakers are  
capable of producing sound pressure levels  
in excess of 85 dB, which may cause perma-  
nent hearing damage.  
An acoustic measuring system such as  
MLSSA or WinMLS is recommended for  
analyzing the effects of the adjustments,  
however, careful listening with suitable test  
recordings can also lead to good results if a  
test system is not available. Table 1 shows  
some typical settings in various situations.  
Figures 8 and 10 show the effect of the con-  
trols on the anechoic response.  
8040A Accessories  
1. Servicing and adjustment must only  
be performed by qualified service  
personnel. The loudspeaker must not be  
opened.  
Order code  
Floor stand black  
8000-400  
Wall mount black (Omnimount) 8040-404-B  
Ceiling mount black  
(Omnimount)  
8040-405-B  
Always start adjustment by setting all  
switches to "OFF” position. Then set only  
one switch per group to the "ON" position to  
select the desired adjustment. If more than  
one switch is set to "ON" (within one switch  
group) the attenuation value is not accurate.  
Measure or listen systematically through  
the different combinations of settings to find  
the best frequency balance.  
2. Do not use this product with an  
unearthed mains cable as this may lead to  
personal injury.  
Wall mount black (K&M)  
Soft carrying bag for two  
monitors  
8000-401  
8040-420  
3. To prevent fire or electric shock, do not  
expose the unit to water or moisture. Do  
not place any objects filled with liquid,  
such as vases on the loudspeaker or near  
it.  
8050A Accessories  
Order code  
Floor stand black  
8000-400  
4. Note that the amplifier is not  
completely disconnected from the AC  
mains service unless the mains power  
cord is removed from the amplifier or the  
mains outlet.  
Wall mount black (Omnimount) 8050-404-B  
Ceiling mount black  
(Omnimount)  
8050-405-B  
Maintenance  
No user serviceable parts are to be found  
Soft carrying bag for one  
monitor  
8050-420  
within the loudspeaker cabinet or the ampli-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Figure 8. The curves above show the effect of the “bass tilt”,  
“treble tilt”, “desktop low frequency” and “bass roll-off” controls  
on the free field response of the 8040A.  
Figure 9. The upper curve group shows the horizontal directivity  
characteristics of the 8040A measured at 1 m. The lower curve shows  
the system's power response.  
Figure 10. The curves above show the effect of the “bass tilt”,  
“treble tilt”, “desktop low frequency” and “bass roll-off” controls  
on the free field response of the 8050A  
Figure 11. The upper curve group shows the horizontal directivity  
characteristics of the 8050A measured at 1 m. The lower curve shows  
the system's power response.  
EC Declaration of Conformity  
Guarantee  
This is to certify that Genelec Monitoring Systems 8040A and 8050A conform to the following standards:  
Genelec 8040A and 8050A are supplied with  
one year guarantee against manufacturing  
faults or defects that might alter the perform-  
ance of the loudspeakers. Refer to supplier  
for full sales and guarantee terms.  
Safety:  
EN 60065 / IEC 60065:1998 6th Edition  
EMC:  
EN 55013: (2001)  
EN 55020: (1994), A11: (1996), A12: (1999), A13: (1999), A14: (1999)  
EN 61000-3-2 (2000)  
EN 61000-3-3 (1995)  
The product herewith complies with the requirements of The Low Voltage Directive73/23/EEC, EMC Directive 89/336/EEC  
and 93/68/EEC  
Signed:  
Ilpo Martikainen  
Position:  
Date:  
Managing Director  
20-April-2004  
Download from Www.Somanuals.com. All Manuals Search And Download.  
8040A and 8050A Operating Manual  
SySTeM SPecIFIcATIoNS  
croSSover SecTIoN  
8040A  
45 Hz  
8050A  
35 Hz  
8040A  
8050A  
Lower cut-off frequency, -3 dB  
Upper cut-off frequency, -3 dB  
Input connector XLR female  
Input impedance  
Pin 1 gnd, pin 2 +, pin 3 -  
10 kOhm balanced  
21 kHz  
21 kHz  
Free field frequency response of  
system ( 2.0 dB)  
48 Hz - 20 kHz  
38 Hz - 20 kHz  
Input level for maximum short term Adjustable from +6 to -6 dBu  
output of 100 dB SPL @ 1m:  
Maximum short term sine wave  
acoustic output on axis in half  
space, averaged from 100 Hz to  
3 kHz  
Crossover frequency, Bass/Treble  
3.0 kHz  
1.8 kHz  
Treble tilt control operating range in From +2 to -4 dB & From +2 to -4 dB &  
2 dB steps  
MUTE @ 15 kHz  
-4 dB @ 160 Hz  
MUTE @ 15 kHz  
-4 dB @ 160 Hz  
@ 1 m  
@ 0.5 m  
105 dB SPL  
111 dB SPL  
110 dB SPL  
116 dB SPL  
Desktop low frequency control  
operating range  
Maximum long term RMS acoustic  
output in same conditions with IEC  
weighted noise (limited by driver  
unit protection circuit) @ 1 m  
99 dB SPL  
115 dB SPL  
10 dB  
101 dB SPL  
120 dB SPL  
10 dB  
Bass roll-off control operating  
range in 2 dB steps  
From 0 to -6 dB  
@ 45 Hz  
From 0 to -6 dB  
@ 35 Hz  
Bass tilt control operating range in  
2 dB steps  
From 0 to -6 dB @  
100 Hz & MUTE  
From 0 to -6 dB @  
100 Hz & MUTE  
Maximum peak acoustic output  
per pair above console top, @ 1  
m from the engineer with music  
material  
The 'CAL' position is with all tone controls  
set to 'off' and the input sensitivity control  
to maximum (fully clockwise)  
Self generated noise level in free  
field @ 1m on axis (A-weighted)  
Harmonic distortion at 90 dB SPL  
@ 1m on axis  
Freq. 50 to 100 Hz  
> 100 Hz  
< 2 %  
< 0.5 %  
< 2 %  
< 0.5 %  
AMPLIFIer SecTIoN  
8040A  
8050A  
Drivers:  
Bass  
Treble  
Both drivers are  
magnetically shielded  
165 mm (6 1/2")  
19 mm (3/4")  
metal dome  
205 mm (8")  
25 mm (1")  
metal dome  
Bass amplifier short  
term output power  
Treble amplifier short  
term output power  
90 W (8 Ohm load) 150 W (6 Ohm load)  
90 W (8 Ohm load) 120 W (8 Ohm load)  
Weight:  
8.6 kg (18.9 lbs)  
12.7 kg (28 lbs)  
Long term output power is limited  
by driver unit protection circuitry  
Dimensions:  
Height (without table support  
350 mm (13 13/16“) 433 mm (17 1/16")  
Height (including table support)  
Width  
Depth  
365 mm (14 3/8“)  
237 mm (9 3/8“)  
223 mm (8 13/16“)  
452 mm (17 13/16")  
286 mm (11 1/4")  
278 mm (10 15/16")  
Amplifier system distortion  
at nominal output  
THD  
0.05 %  
0.05 %  
0.05 %  
0.05 %  
0.05 %  
0.05 %  
0.05 %  
0.05 %  
SMPTE-IM  
CCIF-IM  
DIM 100  
Signal to Noise ratio, referred to  
full output  
Bass  
100 dB  
100 dB  
100 dB  
100 dB  
Treble  
Mains voltage  
100, 120, 220 or 230 V  
according to region  
Voltage operating range  
10 %  
10 %  
Power consumption  
Idle  
10 VA  
10 VA  
Full output  
110 VA  
170 VA  
Genelec Document D0003R001a Copyright Genelec Oy 2.2005-. All data subject to change without prior notice  
International enquiries:  
Genelec, Olvitie 5  
In the U.S. please contact:  
In Sweden please contact:  
In China please contact:  
Genelec, Inc., 7 Tech Circle  
Natick, MA 01760, USA  
Phone +1 508 652 0900  
Fax +1 508 652 0909  
Genelec Sverige  
Beijing Genelec Audio Co. Ltd.  
Jianwai SOHO, Tower 12, Room 2306  
39 East 3rd Ring Road  
FIN-74100, Iisalmi, Finland  
Phone +358 17 83881  
Fax +358 17 812 267  
Box 5521, S-141 05 Huddinge  
Phone +46 8 449 5220  
Fax +46 8 708 7071  
Chaoyang District, Beijing 100022, China  
Phone +86 0 5869 7915  
Fax +86 10 5869 7914  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Ei Electronics Smoke Alarm Ei100L User Manual
Everpure Water System EV943000 User Manual
Extron electronic Stereo Amplifier CVDA 6 EQ MX User Manual
Fellowes Paper Shredder HS 800 User Manual
Fellowes Paper Shredder PowerTrim User Manual
FIC Computer Hardware SMB 710 User Manual
Fujitsu Dollhouse CM81 00304 5E User Manual
Fujitsu Surge Protector FMWSP9 User Manual
Gefen Switch Monitor Switcher User Manual
Gemini Speaker GSS 1522 User Manual