Gefen Switch GEF 3GSDI 16416 User Manual

1080P  
16x16 3GSDI Matrix  
GEF-3GSDI-16416  
User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CONTENTS  
1
Introduction  
Operation Notes  
Features  
2
3
4
Panel Layout  
Front Panel  
4
5
Front Panel Descriptions  
6
Panel Layout  
Back Panel  
6
7
Back Panel Descriptions  
8
Connecting And Operating The 16x16 3GSDI Matrix  
Wiring Diagram  
8
9
The Standby Screen  
9
Displaying the Firmware Version  
Displaying the Boot Loader Version  
Switching between RS-232 and RS-485 Protocols  
Displaying the Routing Status  
Routing Sources  
9
10  
12  
12  
13 IR Remote Description  
14 IR Remote Installation  
15 IR Code Conguration  
16 RS-232 Serial Control  
16  
17  
18  
21  
22  
Settings  
Reference Signal Functions  
IP Conguration Functions  
General Functions  
Commands  
25 IP Control  
25  
26  
27  
28  
View Matrix Status  
Masking  
IP Conguration  
Backup / Restore  
29 Firmware Update  
31 Warning Messages  
32 Rack Mount Safety Information  
33 Specications  
34 Warranty  
35 Licensing  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INTRODUCTION  
Congratulations on your purchase of the 16x16 3GSDI Matrix. Your complete  
satisfaction is very important to us.  
Gefen  
Gefen delivers innovative, progressive computer and electronics add-on solutions  
that harness integration, extension, distribution and conversion technologies.  
Gefen’s reliable, plug-and-play products supplement cross-platform computer  
systems, professional audio/video environments and HDTV systems of all sizes  
with hard-working solutions that are easy to implement and simple to operate.  
The Gefen 16x16 3GSDI Matrix  
Now you can easily combine sixteen cross-platform computers and sixteen digital  
displays using the 16x16 3GSDI Matrix. The Matrix provides a simple, reliable  
and highly effective method of routing multiple computer workstations. Each  
3GSDI source is capable of displaying video on any one of 16 3GSDI displays.  
The Matrix can be controlled by using either the buttons on the front panel, the  
built-in RS-232 interface, or the included IR remote.  
How It Works  
The 16x16 3GSDI Matrix has sixteen (16) inputs and sixteen (16) outputs.  
Connect up to sixteen (16) 3GSDI sources to the 3GSDI input ports. Connect up  
to sixteen (16) 3GSDI outputs to the displays. Plug in the power cord and power  
on the Matrix. The connected displays will show video according to the selection.  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPERATION NOTES  
READ THESE NOTES BEFORE INSTALLING OR  
OPERATING THE 16X16 3GSDI MATRIX  
There is no internal scaling in the 16x16 3GSDI Matrix. All of the attached  
monitors must be able to display the resolutions output by the source  
devices. For maximum compatibility it is recommended that only one  
compatible/common resolution be used by all of the source devices.  
Routing features can be accessed using RS-232 or using IP control.  
IMPORTANT: If the unit is installed in a closed or multi-rack assembly, do  
not block the ventilation holes of the enclosure.  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
FEATURES  
Features  
Increases productivity  
Supports resolutions up to 1080p, 1920x1200, and 2K.  
Front panel control buttons for local switching.  
Status LCD (shows routing status)  
Serial interface for remote control via a computer or control automation  
devices supports RS-232 and RS-485 protocols.  
IP Control  
Discrete IR remote control  
Output masking command  
Seamless switching using external Genlock  
Standby mode  
Grounding pin  
IR Sensor  
IR Extender  
Power On/Off switch  
Redundant Internal AC power supply  
Rack mountable  
Package Includes  
(1) GefenPRO 16x16 3GSDI Matrix  
(1) IR Remote Control unit  
(1) AC Power Cord  
(1) Set of Rack Ears  
(1) User Manual  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
PANEL LAYOUT  
Front Panel  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
PANEL DESCRIPTIONS  
Front Panel  
1
LCD Display  
Displays the current routing status of the Matrix and is also used to manage  
source routing.  
2
3
Power Switch  
Turn the power ON or OFF using this switch.  
Control Buttons  
These buttons are used to navigate the LCD menu system. See pages 9 - 12  
for more information.  
- Left  
Select  
- Right  
- Select  
4
Cancel Button  
This button is used to return the user to the main status screen once a routing  
change has been initiated and the user decides to not continue with the change.  
5
6
IR Window  
Receives signals from the IR Remote Control unit.  
Power Indicator  
This LED indicator will glow red when the power is turned on.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
PANEL LAYOUT  
Back Panel  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
PANEL DESCRIPTIONS  
Back Panel  
1
Reference In Connector  
Connect an external reference to this connector. Bi-level (black burst) and tri-  
level sync are supported.  
2
3
3G-SDI Output Ports (1 - 16)  
Connect 3G-SDI monitors to these ports.  
Grounding Terminal  
Provides a discharge path to ground in case a short circuit occurs between the  
“hot” lead of the power supply and the enclosure of the Matrix. The grounding  
wire should be attached from the grounding terminal to an approved ground  
path.  
4
RS-232 Serial Port  
Connects to the RS-232 control device. The 16x16 3GSDI Matrix may be  
switched remotely using this port. See page 16 for more information.  
5
6
IP Control Interface  
Connect the 16x16 3GSDI Matrix to a network in order to use IP control.  
110/220 AC Power Receptacles  
Connect one power cord to both power receptacles. The redundant (secondary)  
power cable should be connected to an electrical outlet on a different circuit.  
7
Fuse Drawer  
Each power receptacle houses a fuse drawer. Within each fuse drawer are two  
(2) 250 V fuses. One fuse is active and the other is a spare.  
8
9
3G-SDI Input Ports (1 - 16)  
Connect 3G-SDI source devices to these ports.  
Reference Loop Connector  
Reference Loop connector.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
CONNECTING AND OPERATING THE 16X16 3GSDI MATRIX  
How to Connect the 16x16 3GSDI Matrix  
1. Connect up to 16 3G-SDI source devices to the 3G-SDI inputs on the rear  
panel of the 16x16 3GSDI Matrix using SDI cables.  
2. Connect up to 16 3G-SDI displays to the 3G-SDI outputs on the rear panel  
of the 16x16 3GSDI Matrix.  
3. Connect the included power cord to the power input receptacle on the rear  
panel of the 16x16 3GSDI Matrix. Connect the opposite end of the cable into  
a open wall power socket.  
How to Operate the 16x16 3GSDI Matrix  
The 16x16 3GSDI Matrix offers a number of control options. The following  
options can be used to control basic routing functions of the 16x16 3GSDI Matrix:  
1. Front Panel Control Buttons - Pages 9 - 12.  
2. IR Remote Control - Pages 13 - 15.  
3. RS-232 Serial Control - Pages 16 -23.  
4. IP Control - Pages 24 - 27.  
Wiring Diagram for the GefenPRO 16x16 3GSDI Matrix  
SDI CABLE  
16x  
3G-SDI Sources  
Matrix  
16x  
3G-SDI Displays  
GEF-3GSDI-16416  
Attention: This product should always be connected to a grounded  
electrical socket.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
CONNECTING AND OPERATING THE 16X16 3GSDI MATRIX  
The Standby Screen  
The front panel of the 16x16 3GSDI Matrix has a 16 character 2 line LCD display.  
This display will shows the current routing status of the Matrix and will be used to  
perform routing commands and other operations. After the unit is powered on,  
the Standby Screen will be displayed:  
Displaying the Firmware Version  
Press the button to display the firmware version:  
Displaying the Boot Loader Version  
Press the button again to display the boot loader version:  
Press the button once more to return to the Standby Screen.  
NOTE: The Cancel button can be pressed at any time to return to the Standby  
Screen.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
CONNECTING AND OPERATING THE 16X16 3GSDI MATRIX  
Switching between RS-232 and RS-485 Protocols  
Press the button to display the serial interface selection screen:  
Use the or buttons to switch between RS-232 and RS-485 serial protocols.  
The current selection is indicated by the cursor. In the example above, RS-232 is  
the currently selected protocol.  
Once the protocol has been selected, press the Select button to save the  
changes.  
RS-232  
If the RS-232 protocol is selected, the LCD will show the following:  
Press the Cancel button to return to the Standby Screen.  
RS-485  
If the RS-485 protocol is selected, another screen will be displayed asking to  
specify whether or not the cable is terminated:  
Use the or buttons to switch between TERMINATION Off and  
TERMINATION On, then press the Select button to save the changes.  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CONNECTING AND OPERATING THE 16X16 3GSDI MATRIX  
In the example below, TERMINATION Off has been selected. The LCD will now  
show that the RS-485 protocol has been selected, along with the termination-  
type:  
Press the Cancel button to return to the Standby Screen.  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CONNECTING AND OPERATING THE 16X16 3GSDI MATRIX  
Displaying the Routing Status  
From the main screen, press the Select button. When the arrow cursor is next  
to OUTPUT, pressing the or buttons on the front panel will show the current  
routing state of each input and output. The example below shows that Input 1 is  
routed to Output 1.  
Pressing the button again will display the routing state of output 2 and so on.  
Note that the number displayed next to INPUT may be different than the example  
above, depending upon the current routing state.  
Routing Sources  
Example:  
Route the source device connected to In 2 to the display connected to Out 1.  
1. From the Standby Screen, press the Select button on the front panel to  
display the routing status screen.  
2. Press the Select button again to move the cursor to INPUT.  
3. Press the button to set the source to Input 2. The source device  
connected to In 2 is now routed to the monitor connected to Out 1.  
4. Press the Cancel button to return to the standby screen.  
NOTE: The Cancel button can be used to return to the standby screen at  
any time.  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IR REMOTE DESCRIPTION  
RMT-16416IR  
Remote Control Unit  
1
2
1
2
Activity Indicator  
This LED will be activated momentarily each time a button is pressed.  
Display and Source Selection Buttons (1 - 16)  
These buttons are used to select which source is routed to a monitor.  
Routing sources using the Remote Control unit  
Issuing a routing command is a two step process. The rst step is to select the  
monitor (1-16) to which the source will be routed. The second step is to select the  
source (1-16).  
Example:  
Route the source device connected to In 6 to the monitor connected to Out 4.  
1. Press button 4 (Out 4) on the IR remote control unit.  
2. Press button 6 (In 6) on the IR remote control unit.  
The source connected to In 6 will be routed to the monitor connected to Out 4.  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IR REMOTE INSTALLATION  
Installing the RMT-16416IR Battery  
1. Remove the battery cover on the back of the IR Remote Control unit.  
2. Insert the included battery into the open battery slot. The positive (+) side of  
the battery should be facing up.  
3. Replace the battery cover.  
The Remote Control unit ships with two batteries. One battery is required for  
operation and the other battery is a spare.  
Battery Slot  
CAUTION: Risk of explosion if battery is replaced by an incorrect type.  
Dispose of used batteries according to the instructions.  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IR REMOTE CONFIGURATION  
How to Resolve IR Code Conicts  
In the event that IR commands from other remote controls interfere with the  
supplied IR Remote Control unit, changing the IR channel on the IR Remote  
Control unit will x the problem. The IR Remote Control unit has a bank of DIP  
switches used for setting the IR channel.  
The DIP switch bank is located underneath the battery cover.  
Remote Channel 0:  
Default  
Remote Channel 1:  
1
2
1
2
Remote Channel 2:  
Remote Channel 3:  
1
2
1
2
Exposed DIP Switch  
bank between the  
battery chambers.  
It is important that the IR channel on the Remote Control unit, matches the IR  
channel set on the 16x16 3GSDI Matrix. For example, if both DIP switches on  
the IR Remote Control unit are set to IR channel 0 (both DIP switches down),  
then the 16x16 3GSDI Matrix must also be set to IR channel 0. See page 22 on  
how to change the IR channel on the 16x16 3GSDI Matrix.  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RS-232 SERIAL INTERFACE  
What features are available via the RS-232 serial communications port?  
The 16x16 3GSDI Matrix can accept commands through the RS-232 serial  
communications port located on the rear panel. The current RS-232 control  
features are:  
Switching/routing of inputs to outputs without the RMT-16416IR remote  
control.  
How do I use these features?  
These features were initially intended for utilization by custom installers in  
automated setups. However, these features can be tested and used by using any  
Windows-based PC with a terminal program.  
What pins are used for communication with the 16x16 3GSDI Matrix?  
Only pins 2 (Receive), 3 (Transmit), and 5 (Ground) are used for communication.  
A null-modem adapter should not be used with this product.  
5 4 3 2 1  
1 2 3 4 5  
9 8 7 6  
6 7 8 9  
Only Pins 2 (RX), 3 (TX), and 5 (Ground) are used on the RS-232 serial interface  
What are the communication port settings?  
Bits per second ............................................................................................ 19200  
Data bits ............................................................................................................... 8  
Parity ............................................................................................................. None  
Stop bits ................................................................................................................1  
Flow Control .................................................................................................. None  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RS-232 SERIAL CONTROL  
RS-232 Features  
RS-232 remote functions are used to control this product’s features. Features  
include input / output routing and reference signal functions . These features are  
available only through the use of the serial port.  
Functions Syntax  
The syntax for each function is always the same:  
#Function name Space ( _ ) as function name end ag Parameter 1 →  
Space Parameter 2 Parameter n Carriage Return ( \r ) →  
Sample:  
#FunctionName_param1_param2_param3_param4...\r  
Syntax is NOT case sensitive.  
Reference Signal Functions  
Function  
Description  
#CHECKREF  
Display the Reference In signal  
#PRREFTABLE Display the table data  
#CHECKREF Function  
The #CHECKREF function detects the Reference In signal and displays the data  
according to the Reference table.  
Syntax:  
#CHECKREF  
Parameters:  
None  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RS-232 SERIAL CONTROL  
#PRREFTABLE Function  
The #PRREFTABLE function displays the Reference In data table (timings) which  
are recognized by the 16x16 3GSDI Matrix.  
Syntax:  
#PRREFTABLE  
Parameters:  
None  
IP Conguration Functions  
Function  
Description  
#ISPADD  
Sets the IP Address  
#SNETMASK  
#SGATEWAY  
#SPORT  
Sets the Net Mask  
Sets the Gateway  
Sets the Port  
#PRWEBADD  
#RSTIP  
Displays the current IP conguration  
Set IP congurations to default settings  
#ISPADD Function  
The #ISPADD function species a new IP address.  
Syntax:  
#ISPADD param1 param2 param3 param4  
Parameters:  
param1  
param2  
param3  
param4  
IP address  
IP address  
IP address  
IP address  
[0 - 255]  
[0 - 255]  
[0 - 255]  
[0 - 255]  
Notes:  
A reboot is required after using this function.  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RS-232 SERIAL CONTROL  
#SNETMASK Function  
The #SNETMASK function species a new net mask.  
Syntax:  
#SNETMASK param1 param2 param3 param4  
Parameters:  
param1  
param2  
param3  
param4  
Net mask  
Net mask  
Net mask  
Net mask  
[0 - 255]  
[0 - 255]  
[0 - 255]  
[0 - 255]  
Notes:  
A reboot is required after using this function.  
#SGATEWAY Function  
Species the new IP gateway.  
Syntax:  
#SGATEWAY param1 param2 param3 param4  
Parameters:  
param1  
param2  
param3  
param4  
IP address  
IP address  
IP address  
IP address  
[0 - 255]  
[0 - 255]  
[0 - 255]  
[0 - 255]  
Notes:  
A reboot is required after using this function.  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RS-232 SERIAL CONTROL  
#SPORT Function  
Species a new port for a Web server.  
Syntax:  
#SPORT param1  
Parameters:  
param1  
Port  
[0 - 255]  
Notes:  
A reboot is required after using this function.  
#PRWEBADD Function  
Prints the current IP conguration on the screen.  
Syntax:  
#PRWEBADD  
Parameters:  
None  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RS-232 SERIAL CONTROL  
General Functions  
Function  
Description  
#ACTIVEBOLO Enables the boot loader  
#FADEFAULT  
#RMTIRADD  
#RSTIP  
Sets IP Congurations to default settings  
Set the remote IR channel  
Sets IP conguration to default  
#ACTIVEBOLO Function  
The #ACTIVEBOLO function enables the boot loader. See the boot loader  
instructions on page 28.  
Syntax:  
#ACTIVEBOLO  
Parameters:  
None  
Notes:  
This command must be typed twice in order to activate the boot loader.  
#FADEFAULT Function  
The #FADEFAULT function sets all inputs and outputs to factory (default)  
settings.  
Syntax:  
#FADEFAULT  
Parameters:  
None  
Notes:  
The #FADEFAULT function will set the default routing state: Input 1 - Output 1,  
Input 2 - Output 2, Input 3 - Output 3, and so on.  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RS-232 SERIAL CONTROL  
#RMTIRADD Function  
The #RMTIRADD function set the remote IR channel.  
Syntax:  
#RMTIRADD param1  
Parameters:  
param1  
IR channel  
[0 - 3]  
#RSTIP Function  
Sets IP conguration to default (192.168.0.70)  
Syntax:  
#RSTIP  
Parameters:  
None  
Notes:  
This command requires the unit to be rebooted in order to take effect.  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RS-232 SERIAL CONTROL  
Commands  
Command  
Description  
M
R
S
Returns the current routing status of matrix  
Routing command  
Routes a single input to all outputs  
M Command  
The M command displays the current routing status of the matrix.  
Syntax:  
m
Parameters:  
None  
R Command  
The R command allows specic routing of inputs and outputs.  
Syntax:  
r param1 param2  
Parameters:  
param1  
param2  
Ouput  
Input  
[1 - 16]  
[1 - 16]  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RS-232 SERIAL COMMANDS  
S Command  
The S command routes a single input to all 16 3GSDI outputs.  
Syntax:  
s param1  
Parameters:  
param1  
Input  
[1 - 16]  
Notes:  
Setting param1 to a value of 0 will place the matrix in one-to-one mode. This  
means that Input 1 will be routed to Output 1, Input 2 will be routed to Output 2,  
and so on.  
24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IP CONTROL  
The GefenPRO 16x16 3GSDI Matrix supports IP-based control using an  
integrated Web interface. To access this feature, an IP address, subnet, gateway,  
and port number need to be set on the 16x16 3GSDI Matrix (Default IP:  
192.168.0.70 Subnet: 255.255.255.0 Gateway: 192.168.0.1 Port: 80). Consult  
the network administrator to obtain the proper IP address and settings for this  
product to properly communicate on the network.  
The IP control setting can be congured via the RS-232 control interface. Once  
this has been accomplished, access to the Web Interface is possible. Simply type  
the IP address that was assigned to the product in a web browser to access the  
View Matrix Status page.  
View Matrix Status  
The Main Page will display the current status and can also be used to create  
routes.  
To create a new route, follow the steps below:  
1. Select which outputs will display the source by clicking on each check box.  
2. Select the radio button of the input that will be routed to each output.  
3. Click the SWITCH button to update the new routing conguration.  
This page will automatically refresh every minute. However, at anytime the  
“Refresh” button can be pressed to refresh the status of the Matrix.  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IP CONTROL  
Masking  
The Masking page is used to hide an output from displaying any video. From  
this page, all outputs can be set to “Active” or “Mask”. When an output is set to  
“Active”, it will function normally. When an output is set to “Mask”, it will not output  
any video. To set the “Active” or “Mask” mode, follow the steps below.  
1. Select either “Active” or “Mask” for any number of desired outputs.  
2. Press the “Submit” button to initiate the change(s).  
After this command is complete the user will be returned to the Main Page.  
This page will automatically refresh every minute, however, at anytime the  
“Refresh” button can be pressed to refresh the status of the matrix.  
NOTE: All masked outputs will become active if the unit is power-cycled.  
26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IP CONTROL  
IP Conguration  
The IP Conguration page is used to set the IP settings that will be used to  
access the Web interface. The following items can be congured from this menu.  
IP Address (Default: 192.168.0.70)  
Subnet (Default: 255.255.255.0)  
Gateway (192.168.0.1)  
Port (Default: 80)  
To change these settings follow the steps below.  
1. Enter the desired network information into the elds provided.  
2. Press the “Save” button to initiate the change(s).  
Note: After this command is complete the user will be returned to the View  
Matrix Status page. Settings made on this page will not take effect until the  
unit is restarted. Disconnect the power from the unit and reconnect power for  
changes to take effect.  
At anytime, the “Reset” button can be pressed to return the IP settings to their  
defaults.  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IP CONTROL  
Backup / Restore  
The Backup/Restore page is used to backup and restore complete setup  
congurations.  
Note: This feature will be implemented in a future release.  
28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FIRMWARE UPDATE  
Firmware Update Procedure  
To Begin the update procedure the unit’s Boot Loader must be activated. To  
activate the Boot Loader please follow the procedure below:  
If the unit is already powered on, the following RS-232 command can be  
used to activate the Boot Loader:  
1. Connect RS-232 cable to PC and activate a terminal program.  
2. Type the command: #ACTIVEBOLO followed by the ENTER key.  
3. Re-type the command: #ACTIVEBOLO and press the ENTER key.  
If the unit is not powered on, follow the instructions below to activate the  
Boot Loader:  
1. Connect RS-232 cable to PC and activate a terminal program.  
2. Make sure the terminal program is set to the following:  
a. Baud rate = 19200  
b. Stop bits = 1  
c. Data bits = 8  
d. Flow control = None  
3. Press the following three buttons on the front panel of the 16x16  
simultaneously, while powering-on the unit:  
a. select  
b. < (left cursor)  
c. > (right cursor)  
Once the Boot Loader is activated the following message should appear:  
16x16 Boot Loading  
================== Main Menu ============================  
Download new program -------- 1  
Cancel ---------------------- 2  
=========================================================  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FIRMWARE UPDATE  
Follow the on-screen instructions to complete the rmware update  
process:  
1. Press [1] on the computer keyboard to begin downloading program to the  
temporary memory.  
2. A message will appear in Hyperterminal:  
Waiting for the le to be sent ... (press ‘a’ to abort)  
3. In Hyperterminal, click Transfer > Send File...  
4. Click Browse... and select the .BIN le you wish to upload.  
5. Select Ymodem for the protocol.  
6. Press Send on the Send File dialog box.  
7. Wait until the download process is nished. The next text will appear on the  
screen:  
Download Completed Successfully!  
----------------------------------------------  
Name:  
Size:  
3GSDI16x16_e_1_6.bin  
200416 Bytes  
------------------------------------  
Memory copy, please wait...............Finished to copy  
Execute the new version  
GEFEN  
16x16 3GSDI MATRIX  
8. The updated process is now complete.  
30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
WARNING MESSAGES  
System Failure  
In the case of a critical malfunction, the following warning message will be  
displayed on the Main Display:  
If the 16x16 3GSDI Matrix is connected to a PC using a terminal program, the  
following message will appear on the display:  
System failure !!!  
Power-down the Matrix immediately and contact Gefen Technical Support. See  
Asking for Assistance at the beginning of this manual.  
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RACK MOUNT SAFETY INFORMATION  
a. Maximum recommended ambient temperature: 45 ˚C  
b. Increase the air ow to maintain the temperature inside the rack.  
c. Install the product evenly to avoid mechanical overload.  
d. Connect an earthing wire between the an earthing stud and the  
grounding pin on the chassis.  
32  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SPECIFICATIONS  
Input / Output  
SDI (SMPTE 259MI up to 360 Mbps)  
HD-SDI (SMPTE 292M up to 1.485 Gbps)  
3G-SDI (SMPTE 424M/425M up to 3.0 Gbps)  
Supported Formats......................................................All SD, HD, and 3G formats  
Maximum Resolution...........................................................1080p, 1920x1200, 2K  
Input / Output Connector-type..........................................................................BNC  
Input / Output Impedance.................................................................................75 Ω  
Reference (Sync)............................................................NTSC, PAL, and Tri-Level  
RS-232 Interface.................................................................................DB-9, female  
Power Supply..................................................100 ~ 240 V AC (x2 for redundancy)  
Power Consumption........................................................................................30 W  
Operating Temperature...............................................0 ˚C ~ 45 ˚C / 32 ˚F ~ 104 ˚F  
Storage Temperature...............................................-20 ˚C ~ 60 ˚C / -4 ˚F ~ 140 ˚F  
Relative Humidity...............................................20% ~ 90% RH (no condensation)  
Rack mountable................................................ 2U rack space, rack ears included  
Dimensions............................................................................. 19” W x 2U H x 7” D  
Shipping Weight........................................................................................... 29 lbs.  
33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
WARRANTY  
Gefen warrants the equipment it manufactures to be free from defects in material  
and workmanship.  
If equipment fails because of such defects and Gefen is notied within two (2)  
years from the date of shipment, Gefen will, at its option, repair or replace the  
equipment, provided that the equipment has not been subjected to mechanical,  
electrical, or other abuse or modications. Equipment that fails under conditions  
other than those covered will be repaired at the current price of parts and labor in  
effect at the time of repair. Such repairs are warranted for ninety (90) days from  
the day of reshipment to the Buyer.  
This warranty is in lieu of all other warranties expressed or implied, including  
without limitation, any implied warranty or merchantability or tness for any  
particular purpose, all of which are expressly disclaimed.  
1. Proof of sale may be required in order to claim warranty.  
2. Customers outside the US are responsible for shipping charges to and from  
Gefen.  
3. Copper cables are limited to a 30 day warranty and cables must be in their  
original condition.  
The information in this manual has been carefully checked and is believed to  
be accurate. However, Gefen assumes no responsibility for any inaccuracies  
that may be contained in this manual. In no event will Gefen be liable for  
direct, indirect, special, incidental, or consequential damages resulting from  
any defect or omission in this manual, even if advised of the possibility of such  
damages. The technical information contained herein regarding the features and  
specications is subject to change without notice.  
For the latest warranty coverage information, refer to the Warranty and Return  
PRODUCT REGISTRATION  
Please register your product online by visiting the Register Product page  
under the Support section of the Gefen Web site.  
34  
Download from Www.Somanuals.com. All Manuals Search And Download.  
LICENSING  
lwIP is licenced under the BSD licence:  
Copyright (c) 2001-2004 Swedish Institute of Computer Science.  
All rights reserved.  
Redistribution and use in source and binary forms, with or without modication,  
are permitted provided that the following conditions are met:  
1. Redistributions of source code must retain the above copyright notice, this  
list of conditions and the following disclaimer.  
2. Redistributions in binary form must reproduce the above copyright notice,  
this list of conditions and the following disclaimer in the documentation and/  
or other materials provided with the distribution.  
3. The name of the author may not be used to endorse or promote products  
derived from this software without specic prior written permission.  
THIS SOFTWARE IS PROVIDED BY THE AUTHOR ``AS IS’’ AND ANY  
EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO,  
THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR  
A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE  
AUTHOR BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL,  
EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT  
LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES;  
LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)  
HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN  
CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR  
OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE,  
EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.  
35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Rev A3  
20600 Nordhoff St., Chatsworth CA 91311  
1-800-545-6900 818-772-9100 fax: 818-772-9120  
Pb  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Eiki Projector LC 5300U User Manual
Escient Switch LS102 User Manual
EverFocus Security Camera EHD350 User Manual
Fisher Price Model Vehicle 74305 User Manual
Frigidaire Microwave Oven FFMV164L S User Manual
Frymaster Fryer SR52 SR62 User Manual
Furuno SONAR fmv605 User Manual
Gateway Flat Panel Television GTW L17M103 User Manual
GE Universal Remote 24116 User Manual
Gianni Industries Door UBK 010 User Manual