GR585 F1 specifications
Product overview
The Gateway GR585 F1 is a four-socket 2U server for space-conscious users who demand the highest
performance and utmost expansion capability. Delivering the latest technology, this server was designed
for cost-effective growth and includes a comprehensive list of management features.
Internal view
1
2
3
4
5
6
2 x 1400 W 80 PLUS® gold-level efficient easy-swap power supplies (1+1 redundant, hot-pluggable)
4 x AMD Opteron™ 6100 series processors
32 x DDR3 ECC registered / unbuffered DIMMs
N+1 redundant cooling fans
4 x PCIe expansion slots
6 x 3.5” hot-swappable hard drive bays
1
Download from Www.Somanuals.com. All Manuals Search And Download.
GR585 F1 specifications
Memory
• Memory capacity:
•
Registered DIMM: 2, 4, 8, 16 GB
Unbuffered DIMM: 2, 4 GB
•
• Up to 512 GB registered DIMMs when fully populated with 2 DIMMs per channel in 32 slots
• Up to 128 GB unbuffered DIMMs when fully populated with 2 DIMMs per channel in 32 slots
Network Controllers
• Integrated Intel® 82576EB Gigabit Ethernet Controller with dual ports
Storage
• Hard disk form factor: 3.5”
• Type: SAS/ SATA with hot-plug capability
• 3.5” Maximum capacity:
•
Up to 12 TB SATA (2 TB 3.5" x 6 HDDs)
Up to 3.6 TB SAS (600 GB 3.5” x 6 HDDs)
•
Storage Controllers
• Integrated AMD® SP5100 Chipset Serial ATA host controller with RAID 0, 1, 10 support
• Optional PCIe 4-/8-port SAS RAID card
Expansion slots
• Two low profile PCI-E 2.0 x16 slots
• One low profile PCI-E 2.0 x8 slot
• One Gateway Flex I/O x8 or PCI-E 2.0 x8 slot
Management
• Gateway Smart Server Manager
• System ID LED buttons, System Health LED
• Gateway Smart Console for server management and KVM over IP remote management
Deployment/Serviceability
• Gateway Smart Setup
• BIOS Update Tool
• IPMI Firmware Update Tool
Operating Systems
• Windows Server® 2008
• Windows Server® 2008 R2
• Windows Server® 2003
• Red Hat® Enterprise Linux 5
• SuSE® Linux Enterprise Server 11 SP1
• VMware ESXi™ 4 update 1
• VMware ESX™ 4 update 1
Input/output interface
Front
• 2 x USB 2.0 ports
3
Download from Www.Somanuals.com. All Manuals Search And Download.
GR585 F1 specifications
• Serial port
• Network, hard drive and power, and system status indicators
Rear
• PS2 mouse and keyboard ports
• 2 x USB ports
• 2 x Gigabit LAN port (RJ-45)
• Video port
• Serial port
• System ID LED
• Management port (RJ-45)
Chassis/Form Factor
• 2U rack optimized
Power Supply
• 2 x 1400 W 80 PLUS® gold-level efficient, easy-swap power supply (1+1 redundant, hot-pluggable)
Regulatory Compliant Standards
EMC
• FCC (Class A)
• CE (Class A)
• BSMI (Class A)
Safety
• UL/cUL
• CB
Nemko/GS
Environmental Specifications
Dimensions 437 (W) x 709 (D) x 89 (H) mm (17.2 × 27.9 × 3.5 inches)
25.9 kg (57 lbs)
Weight
Maximum
18.6 kg (41 lbs)
Minimum (includes a single HDD, CPU and
RAM, and PSU)
System inlet Operating
temperature
10°- 35°C (50°- 95°F)
-40°- 70°C (-40°- 158°F)
8 - 90 %
Non-operating
Relative
humidity
Operating
Non-operating
Idle
5 - 95 %
Acoustics
LWAd
6.7 BA
LpAm
54.1 dBA
Operating
LWAd
7.7 BA
LpAm
67.7 dBA
4
Download from Www.Somanuals.com. All Manuals Search And Download.
GR585 F1 specifications
Power
Rated Steady –state power
Maximum Peak Power
BTU rating
1400 W
1400 W
4095 BTU/hr at 100 - 140V AC
4778 BTU/hr at 180-240V AC
5
Download from Www.Somanuals.com. All Manuals Search And Download.
GR585 F1 specifications
Technical specifications
PCIe® specifications
The primary I/O bus for the main board is PCIe Gen2. The following table lists the characteristics of the PCI-
E bus segments. Details about each bus segment follow the table.
NOTE: The signaling bit rate of PCI Express is 2.5Gbit/s one direction per lane for Gen 1 and 5.0Gbit/s one
direction per lane for Gen 2.
Expansion
slot
Number
Type
Bus
width1
Voltage
3.3V
Connector Location
Length
PCIe x16
PCIe x81
Flex I/O1
NOTE:
2
PCIe
Gen2
x16
x8
x16
x8
Onboard
Onboard
Onboard
Low-profile
Low-profile
Low-profile
Up to 2
1
PCIe
Gen2
3.3V
PCIe
Gen2
x8
3.3V
x8
1. If the Flex I/O slot is used, the second PCIe x8 cannot be used.
2. Indicates the number of physical electrical lanes running to a PCIe® connector.
2. Default bus assignment (in decimal). Inserting cards with PCI™ bridges may alter the actual bus
assignment number.
3. Slots are enumerated differently based on the operating system. Microsoft® operating systems enumerate
Device ID by bus starting from the lowest bus to the highest.
Onboard storage specifications
Item
Description
Controller
AMD® SP5100 SATA controller
6 onboard SATA ports
3 Gb/s
Simultaneous drive transfer channels
Max throughput per channel
Data transfer method
•
•
Non-RAID mode
RAID mode (Adaptec RAID driver)
Drive type supported
RAID levels support
RAID function support
Serial ATA
•
RAID 0, 1, 10 (Adaptec software RAID)
Supports multiple logical volumes
ꢀ
ꢀ
Setup through ROM based Array Configuration Utility
Installation scripting support
NOTE: This controller does not support LED functions
• Windows Server 2008
• Windows Server 2008 R2
RAID OS support
• Windows Server 2003
• Red Hat Enterprise Linux 5.4
6
Download from Www.Somanuals.com. All Manuals Search And Download.
GR585 F1 specifications
• SuSE Linux Enterprise Server 11
Additional features
•
•
NCQ (Native Command Queuing)
AHCI (Advanced Host Controller Interface)
Onboard LAN specifications
Item
Description
1 x Intel® 82576EB Gigabit Ethernet Controller
(2 ports total)
Controller
Network interface
10Base-T / 100Base-TX / 1000Base-T
Compatibility standards
•
•
•
•
•
IEEE 802.3 Ethernet interface for 10BASE-T
IEEE 802.3ab Ethernet interface for 1000BASE-T,
IEEE 802.3u Ethernet interface for 100BASE-TX
NC-SI, SMBus
Manageability
PXE, iSCSI boot
ꢀ
ꢀ
ꢀ
Intel® I/O Acceleration Technology
Virtual Machine Device Queues (VMDq)
PCI-SIG SR-IOV implementation
Virtualization acceleration
Connector
RJ-45
Supported cable type
CAT 5e wire
Memory specifications and population
Item
Description
Supported memory types
•
•
Registered DDR3 1066 / 1333 MHz
Unbuffered DDR3 1066 / 1333 MHz
NOTE: Gateway does not qualify mixed memory configurations of
memory type, capacity or make.
Population
Gateway’s validated memory populations are listed below.
NOTE: Support for 8 / 16 GB DIMMs may vary by regional
availability.
Dual processor configuration guide
DIMM#
CPU 1
CPU 2
4B
x
4A 3B
3A
2B
2A
1B
x
1A
x
4B
x
4A
3B
x
3A
x
2B
2A
1B
x
1A
x
4
x
x
x
8
x
x
x
x
x
x
x
x
x
x
16
x
x
x
x
x
x
x
7
Download from Www.Somanuals.com. All Manuals Search And Download.
GR585 F1 specifications
Quad processor configuration guide
CPU1
CPU2
CPU3
CPU4
#
4
4
3
3
2
2
1
1
4
4
3
3
2
2
1
1
4
4
3
3
2
2
1
1
4
4
3
3
2
2
1
1
B
A
B
A
B
A
B
A
B
A
B
A
B
A
B
A
B
A
B
A
B
A
B
A
B
A
B
A
B
A
B
A
8
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
16
32
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
On-Line Spare
On-line spare is a RAS mechanism that allows the system to reserve one rank of one logical DIMM to be
used as a spare rank. The spare rank must be greater than or equal to the size of all other ranks in the
system. The system can switch to the spare rank when system software determines that one of the ranks in
the system is no longer functioning properly and needs to be replaced.
Memory Identification
Generally, there are some memory information printed on the label of DIMM, but different vendor may have
different format. For example:
4GB 2Rx4 PC3-10600R xx xx xxx
1. Density
ꢁ
1GB, 2GB, 4GB, 8GB, 16GB
2. Rank
ꢁ
ꢁ
ꢁ
ꢁ
1R = Single Rank
2R = Dual Rank
4R = Quad Rank
Note: if any quad rank DIMM is used, maximum only 2 DIMM per channel can be supported
3. Bit Organization
ꢁ
This platform supports x4 and x8
ꢁ
Note: It’s not recommend to mix DIMM with different bit organization in one system
4. Speed
ꢁ
ꢁ
ꢁ
PC3 – 6400 => DDR3- 800
PC3 – 8500 => DDR3- 1066
PC3 – 10600 => DDR3- 1333
8
Download from Www.Somanuals.com. All Manuals Search And Download.
GR585 F1 specifications
Power specifications
1400W Power Supply
Operational Input 1200W: 100-140 VAC
Voltage Range
1400W: 180 – 240 VAC
(Vrms)
Frequency
Range (Nominal)
(Hz)
60/50
100
120
208
200
220
230
240
Nominal Input
Voltage (Vrms)
Max. Rated
Output Wattage
1237.3
14.21
1237.4
11.95
1403.4
7.92
1403.4
7.62
1403.2
7.13
1403.0
6.83
1403.7
6.55
Nominal Input
Current (A rms)
Max. Rated Input
Wattage Rating
(Watts)
1416.74
1421.0
87.33%
1428.26
1434.0
86.64%
1577.66
1584.0
88.95%
1578.62
1585.0
88.90%
1560.76
1568.6
89.91%
1559.90
1570.9
89.94%
1561.00
1572.0
89.92%
Max. Rated VA
(Volt-Amp)
Efficiency (%) at
Max. Rated
Output Wattage
Power Factor
0.997
1.1
0.996
1.2
0.996
1.1
0.996
1.1
0.995
1.2
0.993
1.2
0.993
1.2
Leakage Current
(mA)
Max. Inrush
Current (A peak)
16.74
4.61
15.98
4.60
16.05
4.63
16.11
4.63
15.70
4.65
15.89
4.72
16.20
4.75
Max. Inrush
Current Duration
(mS)
Max. British
Thermal Unit
Rating (BTU/hr)
4222.90
4223.24
4789.80
4789.80
4789.12
4788.439
4790.82
9
Download from Www.Somanuals.com. All Manuals Search And Download.
GR585 F1 specifications
Gateway server software utilities
Smart Setup 2.0
Easy deployment via the latest version of Gateway’s Smart Setup. Smart Setup is
available both in box as a driver packed installation DVD or a downloadable file to be
put into a USB 2.0 device, and eases the deployment of Gateway servers for any
certified OS. Through its unique interface, users may select to have all the correct
drivers be pre-deployed for the OS of their choosing, as well as setup hardware RAID
devices, BMC settings (where available), and even clone the pre-settings to a
bootable USB device to ease mass server deployments.
Smart Console
Web-based management utility to simplify system management with embedded
iBMC, system monitoring and alerting, event handling, remote power control and
KVM-over-IP. Smart Console is OS independent and offers virtual media through
floppy, ODD, and removable disk.
Smart Server
Manager v1.1
Offering 24-7 monitoring for system health and performance.
ꢀ Delivers proactive event management features including system event logging,
event handling from e-mail and SNMP Trap (PET) alerting.
ꢀ Monitors onboard hardware, operating systems and virtual machines
ꢀ Allows remote control from KVM and Power control
ꢀ Satisfies management in web-based UI, role-based administration, and automated
management scripts.
10
Download from Www.Somanuals.com. All Manuals Search And Download.
GR585 F1 specifications
Available options
Processors (up to 4)
AMD Opteron™ 6100 series processor (12-core)
6176 (12 MB L3 cache, 2.3 GHz, DDR3-1333 MHz, 115W (ACP 80W))
6174 (12 MB L3 cache, 2.2 GHz, DDR3-1333 MHz, 115W (ACP 80W))
6172 (12 MB L3 cache, 2.1 GHz, DDR3-1333 MHz, 115W (ACP 80W))
6168 (12 MB L3 cache, 1.9 GHz, DDR3-1333 MHz, 115W (ACP 80W))
6166HE (12 MB L3 cache, 1.8 GHz, DDR3-1333 MHz, 75W (ACP 65W))
6164HE (12 MB L3 cache, 1.7 GHz, DDR3-1333 MHz, 75W (ACP 65W))
AMD Opteron™ (8-core)
6140 (12 MB L3 cache, 2.6 GHz, DDR3-1333 MHz, 115W (ACP 80W))
6136 (12 MB L3 cache, 2.4 GHz, DDR3-1333 MHz, 115W (ACP 80W))
6134 (12 MB L3 cache, 2.3 GHz, DDR3-1333 MHz, 115W (ACP 80W))
6128 (12 MB L3 cache, 2.0 GHz, DDR3-1333 MHz, 115W (ACP 80W))
6132HE (12 MB L3 cache, 2.2 GHz, DDR3-1333 MHz, 75W (ACP 65W))
6128HE (12 MB L3 cache, 2.0 GHz, DDR3-1333 MHz, 75W (ACP 65W))
6124HE (12 MB L3 cache, 1.8 GHz, DDR3-1333 MHz, 75W (ACP 65W))
Memory
Memory type
Capacities
Registered / Unbuffered DDR3 ECC memory
1 / 2 / 4 / 8 / 16 GB DIMMs
32
DIMM number
Max memory
512 GB (128 GB unbuffered)
Hard drives
Type
Interface, bandwidth
3 Gb/s
Capacities (RPM)
250 GB (7.2K)
500 GB (7.2K)
750 GB (7.2K)
1 TB (7.2K)
Enterprise SATA, 3.5”
2 TB (7.2K)
Enterprise SAS, 3.5”
6 Gb/s
146 GB (15K)
300 GB (15K)
450 GB (15K)
NOTE: SAS drives require an
add-on RAID card
11
Download from Www.Somanuals.com. All Manuals Search And Download.
GR585 F1 specifications
600 GB (15K)
RAID cards
Model
Flex I/O, LSI® SAS 2108*
Port number
RAID support
8 internal ports
0, 1, 5, 6, 10, 50, 60
*Battery Backup Unit BBU07 available
RAID HBA for Tape Drive
Note: LTO tape drives require an add on card for external or internal connectivity
Model
LSI® SAS3442E-R
Port number
RAID support
0, 1, 10
4 internal / 4 external ports
Ethernet network cards
Model
Intel® Gigabit CT2 desktop
adapter
Port number
1
Bandwidth
10/100/1000 Mbps
Supermicro AOC-SG-i2 server
adapter
4
4
2
10/100/1000 Mbps
10/100/1000 Mbps
10 Gbps
Supermicro AOC-SG-i4 server
adapter
Supermicro AOC-STGN-i2S
server adapter (DA2)*
Intel® X520-SR1 server adapter*
Intel® X520-SR2 server adapter*
Intel® X520-LR1 server adapter*
1
2
1
10 Gbps
10 Gbps
10 Gbps
*Note: Intel’s 10GbE cards vary in terms or their connecter type. The X520-DA2 is a copper connector for
lengths up to 7M, while the X520-SR1/2 is an optical connection for cables up to 550M. The X520-LR1 is
for even longer cable lengths up to 10kM.
Fibre Channel HBAs
Model
Port number
Bandwidth
4 Gb/s
Qlogic® QLE2460
Qlogic® QLE2462
Qlogic® QLE2560
Qlogic® QLE2562
1
2
1
2
4 Gb/s
8 Gb/s
8 Gb/s
12
Download from Www.Somanuals.com. All Manuals Search And Download.
GR585 F1 specifications
Tape Backup Unit (TBU)
Model
Tape capacity
400/800 GB
400/800 GB
Form factor
LTO Ultrium-3, 3Gb/s SAS
LTO-4, 3Gb/s SAS
External 1U rack
External 1U rack
TPM module
TPM module with STMicro chip
13
Download from Www.Somanuals.com. All Manuals Search And Download.
GR585 F1 specifications
Service and support
Gateway Servers offer a comprehensive service suite to take care of daily IT needs. Users can select the 3-
year standard warranty or choose extended warranties and services.
In a continuing effort to improve the quality of our products, information in this document is subject to
change without notice. Images shown are only representations of some of the configurations available for
this model. Availability may vary depending on region.
© 2010. All rights reserved.
Microsoft and Windows are registered trademarks of Microsoft Corporation. AMD, AMD logo, Opteron are
trademarks or registered trademarks of AMD Inc.
NOTE: Extension warranty services may vary by country. Please contact Gateway authorized resellers for
more information.
14
Download from Www.Somanuals.com. All Manuals Search And Download.
|