Users Guide  
K5309-5V5 11/08 Rev. A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table of Contents  
System Over view .................................................................................................................... 5  
Introduction .......................................................................................................................... 5  
System Basics ....................................................................................................................... 5  
Using the Voice Message Center ......................................................................................... 7  
Abou t Th e Keyp a d s ................................................................................................................ 8  
General Information ............................................................................................................. 8  
F u n ction s of th e Keyp a d s ...................................................................................................10  
En tr y/Exit Dela ys .................................................................................................................12  
Exit Delay............................................................................................................................ 12  
Entry Delay......................................................................................................................... 12  
Exit Alarms ......................................................................................................................... 13  
Ch eck in g F or Op en Zon es ..................................................................................................14  
Using the [] Key ................................................................................................................ 14  
Ar m in g th e System ...............................................................................................................15  
Stay Mode: Arms Perimeter Only, Entry Delay On ......................................................... 15  
Night-Stay Mode: Arms Perimeter Only, Plus Selected Zones ....................................... 15  
Instant Mode: Arms Perimeter Only, Entry Delay Off.................................................... 15  
Away Mode: Arms Entire System, Entry Delay On ......................................................... 15  
Maximum Mode: Arms Entire System, Entry Delay Off................................................. 15  
Arming Commands ............................................................................................................. 16  
Single Button Arming ........................................................................................................ 17  
Single-Button Step” Arming............................................................................................. 17  
Usin g th e Keysw itch ............................................................................................................18  
Using the Keyswitch........................................................................................................... 18  
Disa r m in g a n d Silen cin g Ala r m s .....................................................................................19  
Using the [OFF] key ........................................................................................................... 19  
Byp a ssin g P r otection Zon es ..............................................................................................20  
Using the BYPASS Key...................................................................................................... 20  
Quick Bypass ...................................................................................................................... 21  
Ch im e Mod e ...........................................................................................................................22  
Da te a n d Tim e .......................................................................................................................23  
Viewing the Current Date and Time................................................................................. 23  
Setting the Date and Time................................................................................................. 23  
– 3 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table of Contents  
P a n ic Keys ..............................................................................................................................24  
Ma cr o Key P r ogr a m m in g & Usa ge ...................................................................................25  
About Macro Keys............................................................................................................... 25  
Example of Macro Programming ....................................................................................... 26  
Using a Programmed Macro Key....................................................................................... 26  
Usin g Device Com m a n d s ....................................................................................................27  
P a gin g F ea tu r e .....................................................................................................................28  
About Automatic Paging .................................................................................................... 28  
Manual Paging.................................................................................................................... 29  
Latch Key Paging ............................................................................................................... 29  
Secu r ity Cod es & Au th or ity Levels..................................................................................30  
About Security Codes ......................................................................................................... 30  
Authority Level Definitions ............................................................................................... 30  
How To Assign Security Codes and Attributes................................................................. 31  
Accessin g Oth er P a r tition s (GOTO Com m a n d a n d Mu lti-P a r tition Ar m in g) ......32  
About Accessing Partitions ................................................................................................ 32  
Using the GoTo Command ................................................................................................. 33  
Multi-Partition Arming ...................................................................................................... 33  
Common Zone Operation.................................................................................................... 34  
Sch ed u lin g .............................................................................................................................35  
About Scheduling................................................................................................................ 35  
Creating Schedules ............................................................................................................. 35  
Even t Loggin g P r oced u r es.................................................................................................37  
About Event Logging .......................................................................................................... 37  
Viewing the Event Log ....................................................................................................... 37  
Testin g t h e System (To Be Con d u cted Week ly) ............................................................38  
Tr ou ble Con d ition s ..............................................................................................................39  
Ma in ta in in g You r Syst em ...................................................................................................42  
F ir e Ala r m System (If In sta lled ).......................................................................................43  
Qu ick Gu id e to Ba sic System F u n ction s ........................................................................47  
Su m m a r y of Au d ib le/Visu a l Notifica tion s......................................................................48  
R egu la tor y Sta tem en ts a n d Wa r n in gs ............................................................................50  
Ch a r ts of You r System 's F ea tu r es ....................................................................................52  
– 4 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Overview  
Introduction  
Congratulations on your ownership of a First Alert Professional Security System. You've  
made a wise decision in choosing it, for it represents the latest in security protection  
technology today. This system provides:  
Three forms of protection: burglary, fire* and emergency  
At least one keypad which provides control of system and displays system status  
Various sensors for perimeter and interior burglary protection  
Smoke or combustion detectors* designed to provide early warning in case of fire.  
Your system may also have been programmed to automatically send alarm or status  
messages over the phone lines to a Central Monitoring Station.  
* Commercial installations and some residential systems may not include fire  
protection – check with your installer.  
NOTE: The features and procedures described in this manual apply to the  
FA168CPS/FA168CPSSIA (referred to as FA168CPS) and FA148CP/FA148CPSIA  
(referred to as FA148CP) security systems. Differences are noted where applicable.  
System Basics  
Bu r gla r y P r otection  
Several modes of burglary protection: Stay, Night-Stay, Away, Instant, Maximum.  
STAY: arms perimeter zones only and entry delay is on  
INSTANT: same as STAY, except entry delay is off  
NIGHT-STAY: arms perimeter zones and selected interior zones; entry delay on  
AWAY: arms perimeter and all interior zones, entry delay is on  
MAXIMUM: same as AWAY, except entry delay is off  
You can BYPASS selected zones while leaving the rest of the system armed.  
CHIME mode alerts you to the opening of protected doors and windows while the  
system is disarmed.  
F ir e P r otection  
Fire protection is always active (if installed) and an alarm sounds if a fire  
condition is detected  
If programmed, you can manually initiate a fire alarm using the keypad.  
Refer to the Fire Alarm System section for information regarding fire protection,  
smoke detectors and planning emergency exit routes.  
Secu r ity Cod es  
You were assigned a 4-digit security code (master code) during installation.  
Use your security code when arming and disarming the system, and when  
performing other system functions.  
Other users can be assigned different security codes, each with different  
authority levels, which define the system functions a particular user can perform.  
– 5 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Overview (Continued)  
Zon es a n d P a r tition s  
The system sensing devices have been assigned to various zones,” which are  
specific areas of protection (e.g., front door, kitchen window, etc.).  
Zone numbers are displayed at the keypad when an alarm or trouble condition  
occurs on a sensor.  
Partitions (FA168CPS) provide two independent areas of protection, with each  
partition containing a group of zones that can be armed and disarmed without  
affecting other zones or users.  
Partitioned systems (FA168CPS) can include a common zone area, which is an  
area shared by users of both partitions (such as a lobby in a building).  
Ar m in g, Step -Ar m in g a n d Disa r m in g Bu r gla r y P r otection  
The system must be armed before the burglary protection can sense intrusions.  
To arm your system, enter your security code followed by the desired arming key.  
If programmed, you can press the [#] key in place of your security code when  
arming the system (e.g., instead of entering your 4-digit security code + [3-STAY]  
to arm the system in STAY mode, you can press [#] + [3-STAY]).  
You can use the step-arming key, if programmed, to arm the system, which lets  
you arm the system in one of three modes by simply pressing the key repeatedly.  
To disarm the system, enter your security code then press the [OFF] key.  
Ala r m s  
When an alarm occurs, both the keypad and external sounders will sound, and  
the keypad will display the zone(s) causing the alarm.  
If your system is connected to a Central Monitoring Station, an alarm message is  
also sent. (Dela yed R ep or tin g Note: Message reporting is delayed 30 seconds by  
default to reduce false alarms. If desired, this delay can be removed or can be  
increased to 45 seconds. See your installer if you want the delay time changed.)  
To stop the alarm sounding, simply disarm the system.  
Mem or y of Ala r m  
When an alarm condition occurs, the keypad displays the number(s) of the  
zone(s) that caused the problem, and displays the type of alarm (e.g., FIRE).  
The message remains displayed even after disarming the system, but can be  
cleared with another off” sequence.  
F u n ction Keys  
The A”, B, “C, and D” keys on the keypad can be programmed to perform  
various functions.  
Functions include: activate a Panic alarm; arm the system; provide step arming;  
switch lights on/off; send a message to a pager; display Time/Date; start a Macro.  
Sch ed u lin g  
Your system can be programmed to automatically perform certain functions (e.g.,  
arm the system) at a predetermined time each day.  
– 6 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Overview (Continued)  
P h on e Access  
If included, a Phone Module permits you to access the system via a touch-tone  
phone, either on-premises or by calling-in when away.  
You can receive synthesized voice messages over the telephone regarding the  
status of the security system.  
You can arm and disarm the system and perform most function commands  
remotely via the telephone, with voice confirmation provided after each command.  
Refer to the P h on e Access User 's Gu id e supplied with the Phone Module for  
information regarding the use of this feature.  
P a gin g F ea tu r e  
If programmed, the system can automatically send certain system condition  
messages to up to four (FA168CPS) or two (FA148CP) pagers.  
The system can also automatically alert a pager if the system has not been  
disarmed by a certain time (e.g., can let you know a child has not arrived home).  
You can also manually send a message to designated pagers.  
Using the Voice Message Center (if Voice Keypad is installed)  
LEDS  
The Voice Keypads feature a voice message center  
LCD  
DISPLAY  
that lets you record and playback one message.  
The message can be up to 2.5-minutes long  
ARMED READY MESSAGE  
SPEAKER  
The message remains in the keypads memory  
until a new message is recorded.  
VOLUME  
KEY  
RECORD  
KEY  
PLAY KEY  
AND  
UP VOLUME  
A
B
C
D
1
2
3
PLAY  
The volume control of the message is adjustable.  
RECORD  
VOLUME  
4
7
5
8
0
6
9
FUNCTION  
KEYS  
DOWN  
Refer to the procedures below when using the  
Message Center functions.  
VOLUME  
#
STATUS  
VOICE  
FUNCTION  
FUNCTION  
KEY  
*
FA560  
MICROPHONE  
STATUS  
KEY  
VOICE  
KEY  
FA560VKP-004-V0  
Messa ge Cen ter F u n ction s  
To…  
P r ess th ese k eys…  
Notes…  
record a  
message  
The red MESSAGE LED lights.  
Message remains in memory  
until a new message is recorded.  
[#] FUNCTION + [0] VOICE + [1] RECORD  
end  
recording  
The red MESSAGE LED flashes,  
indicating message waiting.  
[1] RECORD  
play a  
message  
The recorded message plays and  
the red MESSAGE LED turns off.  
[#] FUNCTION + [0] VOICE + [3] PLAY  
adjust the  
volume  
Adjusting message volume also  
adjusts status volume. Volume  
cannot be adjusted while playing.  
[#] FUNCTION + [0] VOICE + [2] VOLUME keys,  
then press volume key [3] (up) or [6] (down)  
– 7 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
About The Keypads  
General Information  
Your keypads allow you to control all system functions. The keypads feature the  
following:  
A telephone style (digital) keypad  
Liquid Crystal Display (LCD) which shows the nature and location of all  
occurrences  
Built-in sounder which will sound during alarms and troubles. The sounder also  
"beeps" during certain system functions and when depressing any of the keys (to  
acknowledge the key press).  
Backlighting of the LCD display windows. Backlighting turns on when any key is  
pressed, and when opening an entry/exit door while the system is armed. This  
feature is helpful when a keypad is located in a dimly lit area.  
IMP OR TANT: If the keypad beeps rapidly upon entering the premises, it indicates  
that an alarm has occurred during your absence and an intruder may still be on the  
premises. LEAVE IMMEDIATELY and CONTACT THE POLICE from a nearby safe  
location.  
Your keypads are functionally the same, but may have different types of displays,  
depending on the type installed with your system.  
Alp h a Disp la y  
2-line alpha display keypads feature a 2-line, 32-character  
alphanumeric LCD which can display system messages in  
friendly English. These keypads can also be programmed with  
custom zone descriptors.  
F ixed -Wor d Disp la y Fixed-Word display keypads are functionally identical to Alpha  
display keypads, but the LCD display uses pre-designated  
words to identify the nature and location of occurrences.  
Voice Keyp a d s  
Voice Keypads (if installed), are functionally the same as other  
keypads, except that these keypads can provide the following:  
Voice announcements of system status (see Checking for  
Open Zones section)  
Voice chime, which can alert you to the opening of doors and  
windows while the system is disarmed (see Voice Chime in  
Chime mode section)  
Message center, which lets you record and playback  
messages (see Using the Voice Message Center in the  
System Overview section).  
– 8 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
About The Keypads (Continued)  
Fixed-Word Display Keypad  
AWAY: All burglary zones, interior and  
NIGHT NO AC  
PHONE TEST  
NOT READY  
CHIME BAT  
AWAY  
perimeter, are armed.  
BYPASS  
STAY: Perimeter burglary zones, such as  
protected windows and doors, are  
armed.  
ALARM STAY  
CHECK INSTANT CANCELED  
FIRE  
FA260KP  
INSTANT: Entry delay is turned off:  
AWAY  
STAY  
INSTANT  
NO AC  
CHIME  
BAT  
Lit with STAY = Instant mode  
Lit with AWAY = Maximum mode  
ALARM  
BYPASS CANCELED  
CHECK  
FIRE NIGHT  
NOT READY  
BYPASS: This appears when one or more  
burglary protection zones have been  
bypassed.  
FA215KP  
FIXED-WORD DISPLAYS  
NOT READY: Appears when burglary portion of the system is not ready for arming  
(due to open protection zones). The system is ready to arm when this  
message disappears and the READY indicator light comes on.  
NO AC: Appears when AC power has been cut off. System is operating on  
backup battery power.  
AC: Appears when AC power is present.  
CHIME: Appears when the CHIME feature is activated.  
BAT: Low battery condition in a wireless sensor (if zone number displayed)  
or low system battery (if no zone number displayed).  
ALARM: Appears when an intrusion has been detected and the system is armed  
(also appears during a fire alarm or audible emergency alarm).  
Accompanied by the protection zone in alarm.  
CHECK: Appears when a malfunction is discovered in the system at any time or  
if an open is detected in a FIRE zone at any time or a fault in a  
DAY/NIGHT burglary zone during a disarmed period. Accompanied by  
a display of zone number in trouble.  
FIRE: Appears when a fire alarm is present. Accompanied by a display of the  
zone in alarm.  
A FIRE display also appears when a fire alarm is manually activated,  
accompanied by a display of emergency key zone number programmed  
for fire.  
NIGHT: Appears with STAY” when the system is armed in Night-Stay mode  
(perimeter burglary zones and pre-selected interior zones are armed).  
CANCELED: Appears when an alarm has been canceled (see Exit Alarm section on  
page 13 for more information on canceled alarms and displays).  
– 9 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Functions of the Keypads  
NOTE: The functions printed directly on the  
6 BYPASS Removes individual protection zones  
keys indicate their primary purpose; the  
functions printed under some of the keys (shown  
in brackets under the respective key), indicate  
their alternate or secondary purpose.  
from being monitored by the system.  
[ ] On Voice keypads, used in conjunction with the  
FUNCTION and VOLUME keys to lower the message  
and voice system status volume.  
7 INSTANT Arms in manner similar to the STAY  
DISP LAY WINDOW  
Alph a Displa y Keypa d s: 2-line, 32-character  
Liquid Crystal Display (LCD) keypads that display  
protection point identification, system status, and  
messages.  
mode, but without the entry delay feature.  
9 CHIME Turns  
When on,  
CHIME mode on and off.  
the opening of windows or doors while the system is  
disarmed sounds 3 beeps at the keypad(s).  
Fixed -Wor d  
Displa y  
Keypa d s:  
Display  
protection zone ID and system status messages using  
pre-designated words in the LCD display area.  
KEYS 0–9: Used to enter your security code(s).  
READY Used to display open protection zones.  
1 OFF  
system,  
Disarms burglary portion of the  
[STATUS]: On Voice keypads, one press of the  
STATUS key annunciates the current system status.  
Pressing the STATUS key a second time annunciates  
and displays system and/or zone faults (if they exist).  
silences alarms and audible trouble indicators, and  
clears visual display after problem's correction.  
[RECORD] On Voice keypads, used in conjunction  
with the FUNCTION and VOICE keys to record up to  
a 2.5-minute message.  
0
[VOICE] On Voice keypads, enables the  
RECORD, VOLUME and PLAY functions.  
This key can be used for "Quick Arming" of the  
2 AWAY  
Arms the entire burglary system,  
perimeter and interior.  
#
[VOLUME] On Voice keypads, used in conjunction  
with the FUNCTION and desired volume control keys  
[3] or [6] to adjust the volume of a recorded  
message or voice system status.  
system without use of a security code (if programmed).  
[FUNCTION] On Voice keypads, enables the desired  
voice or volume function.  
F UNCTION KEYS: Keys A, B, C, D may have been  
set for certain functions, such as panic (emergency)  
functions. For details, see the Function Keys section.  
ARMED LED INDICATOR : (RED) Lit when the  
system has been armed.  
READY LED INDICATOR: (GREEN) Lit when  
the system is ready to be armed (no faults present).  
While the system is disarmed, this indicator will go on  
and off as protection zones are closed and opened.  
MESSAGE LED INDICATOR: (RED) On Voice  
keypads, flashes red when message waiting or lights  
red (steady) when in record mode.  
3 STAY  
Arms perimeter portion of burglary  
system only. Interior protection is not armed, allowing  
movement within premises without causing an alarm.  
If pressed twice in succession, arms system in Night-  
Stay mode.  
[PLAY] On Voice keypads, used in conjunction with  
the FUNCTION and VOICE keys to play the recorded  
message.  
[ ] On Voice keypads, used in conjunction with the  
FUNCTION and VOLUME keys to raise the message  
and voice system status volume.  
MIC: On voice keypads, microphone for Message  
Center recordings.  
4 MAXIMUM Arms the entire burglary system,  
perimeter and interior, but without entry delay feature.  
Entering via an entry/exit door will cause an alarm.  
INTERNAL SP EAKER: The built-in speaker  
mimics the alarm sounder during alarms, and will  
also "beep" during certain system functions. The  
speaker also provides voice playback for any recorded  
messages.  
5 TEST  
Tests the system and alarm sounder if  
disarmed. Refer to Testing The System section for test  
procedures.  
8 CODE  
Used to assign additional security codes  
and attributes for other users of the system.  
– 10 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Functions of the Keypads (Continued)  
LEDS  
LCD  
DISPLAY  
ARMED READY MESSAGE  
SPEAKER  
A
B
C
D
1
2
3
PLAY  
RECORD  
VOLUME  
4
7
5
8
0
6
9
FUNCTION  
KEYS  
#
STATUS  
VOICE  
FUNCTION  
*
FA560  
FA560VKP-003-V0  
MICROPHONE  
Voice-capable 2-line Alpha keypad  
IMP OR TANT!  
When entering codes and commands, sequential key depressions must be made  
within 4-5 seconds of one another. If 4-5 seconds elapse without a key depression, the  
entry will be aborted and must be repeated from its beginning. Be sure to observe  
this precaution when performing any of the procedures in this manual.  
If you make a mistake while entering a security code, stop, press the [] key, and  
then start over. If you stop in the middle while entering a code, and then  
immediately start the entry over, an erroneous code might be entered.  
– 11 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Entry/Exit Delays  
Exit Delay  
E xit d ela y gives you time to leave through the designated exit door(s) without setting  
off an alarm. Exit delay begins immediately after arming your system in any arming  
mode and Alpha Display keypads display the message You May Exit Now.” When  
“You may exit now” disappears, the system is fully armed. If programmed, a slow  
beeping will sound during the exit delay period until the last 10 seconds, which then  
changes to fast beeping (alerting you to the end of exit delay). If you cannot leave by  
this time, you should stop, disarm the system, and start over to avoid a false alarm.  
E xit Dela y R esta r t . If you wish to open the entry/exit door to let someone in after  
arming STAY, you can re-start the exit delay at any time – sim p ly p r ess th e []  
k ey, then let that person in (the perimeter zones remain armed). The system  
automatically re-arms the entry/exit door when exit delay expires, which avoids  
having to disarm the system and then re-arm it again. In addition, when the system  
is armed AWAY, reopening and closing the entry/exit door before exit delay time  
expires (e.g., reentering to get a forgotten item) will reset the exit delay time once.  
Entry Delay  
Entry Delays give you time to disarm the system when you re-enter through the  
designated entrance door. There are two entry delays (if programmed). The first is for  
your primary entrance and the second can be used for a secondary entrance, where a  
longer delay is required to walk to the keypad to disarm the system.  
You must disarm the system before the entry delay period ends, or an alarm will  
occur. The keypad beeps during the entry delay period, reminding you to disarm the  
system. The beeps stop when a code is entered, but will restart after about 15 seconds  
if an invalid code is entered.  
You can also arm the system with no entry delay at all by using the INSTANT or  
MAXIMUM arming modes. These modes provide greater security while on the  
premises or while away for extended periods of time.  
You can also arm the system with no entry delay at all by using the INSTANT or  
MAXIMUM arming mode. This mode provides greater security while on the  
premises or while away for extended periods of time.  
See your installer for your delay times.  
P a r tition 1____________________________________________________________________________  
Exit Delay:  
seconds; Entry Delay 1:  
seconds; Entry Delay 2:  
seconds  
NOTE: Entry/Exit times set for partition 1 also apply to the common zone (FA168CPS).  
P a r tition 2 (F A168CP S)_______________________________________________________________  
Exit Delay:  
seconds  
Entry Delay 1:  
seconds Entry Delay 2:  
seconds  
– 12 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Entry/Exit Delays (Continued)  
Exit Alarms  
E xit E r r or Con d ition s  
Whenever you arm the system, the exit delay begins. If an entry/exit door or interior  
zone is faulted before exit delay expires and remains faulted (e.g., exit door left open),  
the system sounds an alarm and starts the en tr y delay timer. If you disarm the  
system before the entry delay ends, the alarm sound stops and the message "ALARM  
CANCELED " or "CA" is displayed on the keypad, along with a zone number  
indicating the faulted zone. No message is sent to the Central Monitoring Station.  
To clea r th e exit er r or con d ition , the open zone must be made intact; to clear the  
display, enter your code plus OFF.  
If you do not disarm the system before the entry delay ends and the faulted zone  
remains open, the alarm sound continues and an "exit alarm" message is sent to the  
Central Monitoring Station (after the installer-programmed dial delay expires). The  
message "EXIT ALARM" or "EA" is displayed on the keypad, along with a zone  
number indicating the faulted zone. To stop the alarm, the system must be disarmed  
(your code plus OFF); to clear the display, enter your code plus OFF a second time.  
An “exit alarm” also results if an entry/exit door or interior zone is faulted within two  
minutes after the end of the exit delay.  
Your system may have been programmed for this feature to minimize false alarms sent to the Central Monitoring  
Station. Ask your installer if "Exit Alarm" is active in your system. If so, check this box.  
F A168CP SSIA/F A148CP SIA: The Exit Error condition works the same as described above,  
except that in addition to the EXIT ALARM” message, a zone alarm” message is also sent to  
the Central Monitoring Station. In addition, if an entry/exit door or interior zone is faulted  
within two minutes after the end of the exit delay, a Recent Closing” condition occurs instead of  
the exit alarm.” Refer to the next paragraph for details.  
Recen t Closin g” Con d ition (F A168CP SSIA/F A148CP SIA)  
A Recent Closing condition is similar to the Exit Error condition described above, but occurs if  
an entry/exit door or interior zone is faulted within two minutes a fter the initial exit delay  
expires. If you disarm the system within the two minutes, the alarm sound stops and the  
message "ALARM CANCELED " or "CA" is displayed on the keypad, along with a zone number  
indicating the faulted zone. No message is sent to the Central Monitoring Station.  
If you do not disarm the system within two minutes and the faulted zone remains open, the  
alarm sound continues and a recent closing” and a zone alarm” message are sent to the  
Central Monitoring Station (after the installer-programmed dial delay expires). The alarm  
message along with a faulted zone number is displayed on the keypad. To stop the alarm, the  
system must be disarmed (your code plus OFF); to clear the display, enter your code plus OFF a  
second time.  
– 13 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Checking For Open Zones  
Using the [] Key  
Before arming your system, all protected doors, windows and other protection zones  
must be closed or bypassed, otherwise the keypad will display a "Not Ready" message.  
Use the READY key to display all faulted zones, making it easier for you to identify  
and secure any open zone.  
1. Press [] (do not enter code first) to display faulted  
Alpha Display:  
zones.  
DISARMED  
HIT FOR FAULTS  
2. Secure or bypass the zones displayed.  
3. The keypads READY indicator lights when all  
protection zones have been either closed or bypassed.  
4. Arm the system as desired.  
Fixed-Word Display:  
Zone no. and “NOT READY”  
Voice Sta tu s: Voice Keypads (if installed), can announce system status and faulted  
zones (up to 3 zone descriptors) if the Voice Status feature is turned on.  
To tu r n th e Voice Sta tu s fea tu r e on /off:  
#
+
0
+
2
+
4
(also turns on Voice Chime mode; see Chime mode section)  
To a n n ou n ce Sta tu s: Press [#] FUNCTION + [0] VOICE + [] STATUS key.  
(Announces current system status; e.g., Disarmed Ready to  
Arm.)  
To a n n ou n ce fa u lts Press [#] FUNCTION + [0] VOICE + [] STATUS + [] again.  
a n d Sta tu s:  
(Announces up to three faulted zones with their zone  
descriptors, if programmed.)  
– 14 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Arming the System  
Stay Mode: Arms Perimeter Only, Entry Delay On  
Used when you want to arm the system with persons staying inside (or if you have  
pets that are moving throughout the premises).  
The perimeter sensors are armed, but interior sensors are left disarmed.  
Exit delay begins (you can leave through the entry/exit door, if desired).  
An alarm sounds if any protected window or non-entry/exit door is opened.  
You may otherwise move freely within the premises.  
Persons entering later can enter through an entry/exit door, but they must disarm  
the system within the entry delay period to avoid sounding an alarm.  
Night-Stay Mode: Arms Perimeter Only, Plus Selected Zones  
Use Night-Stay mode to provide increased security while staying inside.  
Arms same as Stay mode, but also arms pre-selected interior sensors (programmed  
by your installer), while other interior sensors are left disarmed.  
Persons entering later can use entry/exit doors but they must disarm the system a n d  
must not violate any of the programmed interior zones to avoid sounding an alarm.  
IMPORTANT: When Night-Stay mode is on, the selected interior zones are armed and cause an  
alarm if anyone enters those areas (e.g., waking in the middle of the night). To avoid sounding an  
alarm, you must disarm the system before any activity takes place in those interior zones.  
Instant Mode: Arms Perimeter Only, Entry Delay Off  
Used when staying inside and do not expect anyone to use an entry/exit door.  
Arms same as Stay mode.  
An alarm sounds immediately if any protected perimeter window or any door is  
opened, including entry/exit doors.  
IMPORTANT: Arming in this mode greatly increases the chance of false alarms. Use extreme  
care in selecting this mode of arming.  
Away Mode: Arms Entire System, Entry Delay On  
Used when nobody will be staying inside (including pets).  
The entire system (interior and perimeter) is armed.  
Exit delay begins letting you leave through the entry/exit door.  
An alarm sounds if a protected window or any door is opened, or if any movement  
is detected inside your premises.  
You can reenter through an entry/exit door, but you must disarm the system within  
the entry delay period to avoid sounding an alarm.  
Maximum Mode: Arms Entire System, Entry Delay Off  
Used when leaving the premises for extended periods (e.g., vacation).  
Arms same as Away mode, but entry delay is off.  
An alarm sounds same as Away mode, and sounds upon opening entry/exit doors.  
– 15 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Arming the System  
Arming Commands  
Before arming, close all perimeter doors and windows and make sure the Ready to Arm  
message is displayed.  
Mod es of Ar m in g  
Mod e  
Stay  
P r ess th ese k eys…  
security code + [3] (STAY)  
Keyp a d Con fir m s By…  
three beeps†  
armed STAY message displayed  
red ARMED indicator lights  
three beeps†  
Night-Stay security code + [3] + [3]  
NIGHT-STAY message displayed  
red ARMED indicator lights  
three beeps†  
Instant  
Away  
security code + [7] (INSTANT)  
security code + [2] (AWAY)  
armed STAY message displayed  
red ARMED indicator lights  
also note that entry delay is turned off.  
two beeps, or, if programmed, beeping for  
duration of exit delay  
armed AWAY message displayed  
red ARMED indicator lights  
Leave the premises through an entry/exit  
door during the exit delay period to avoid  
causing an alarm. The keypad beeps rapidly  
during the last 10 seconds of the exit delay  
to warn you that it is ending.  
Maximum  
security code + [4] (MAXIMUM)  
same as Away (described above)  
Note that entry delay is turned off.  
Ar m in g Din g: In addition to the keypad beeps, the external sounder emits  
a
short ding” sound after arming, if  
programmed to do so. The ding confirms that the system is armed, and may occur immediately after the command or be  
delayed (until arm/disarm report is sent or exit delay expires). Ask your installer about how this feature is set for your system.  
Qu ick Ar m in g  
If "Quick Arming" was programmed by the installer, the [#] key can be pressed in place  
of the security code when arming the system in any of its arming modes (except Night-  
Stay). However, th e secu r ity cod e m u st a lw a ys b e u sed w h en m a n u a lly  
d isa r m in g th e system .  
F u n ction Key Ar m in g  
For any arming command, a function key may have also been programmed for your  
system. If so, you can press and hold the appropriate function key for 2 seconds to arm  
the system. See your installer for the designated functions (see Sin gle Bu tton  
Ar m in g section).  
Refer to the Accessin g Oth er P a r tition s section for information on multi-partition  
arming (FA168CPS).  
– 16 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Arming the System  
Single Button Arming  
The A”, “B, “C, and/or “D” keys on your keypad may have been programmed for  
single-button arming. Note that while it is not necessary to use a security code for  
arming (by using the Quick Arm method described previously), a security code must  
always be used when manually disarming the system.  
If Single-Button Arming is programmed:  
A function key has been assigned to a specific type of arming: STAY mode,  
Night-STAY mode, AWAY mode, or STEP-ARMING (see Step-Arming  
paragraph).  
You DO NOT need to enter your security code before pressing the function key  
(but you always need your security code to DISARM the system).  
Before arming, close all perimeter doors and windows.  
Alpha Display:  
1. Press and hold the assigned function key for 2  
seconds (no code is required). Function keys are  
shown below.  
DISARMED  
READY TO ARM  
OFF  
AWAY  
TEST  
CODE  
STAY  
A
B
C
D
1
4
7
2
5
8
0
3
6
9
#
BYPASS  
CHECK  
MAX  
Fixed-Word Display: READY  
INSTANT  
READY  
*
2. The keypad begins beeping and displays the armed  
Alpha Display:  
message. The red ARMED indicator also lights.  
ARMED***AWAY***  
YOU MAY EXIT NOW  
Fixed-Word Display: AWAY  
Step Arming Feature  
Single-Button Step” arming may have been programmed into one of the lettered keys  
(A, B, C, or D). Check with your installer to see if this has been done in your system.  
If Step-Arming is programmed:  
The assigned key provides a choice of three levels of security.  
The selected key can be pressed once, twice, or three times, increasing the level  
of security with each press, as follows  
Key  
F ir st P r ess  
Ø
Secon d P r ess  
Ø
Th ir d P r ess  
Ø
Ø
Armed-STAY  
Armed Night-STAY  
Armed-AWAY  
A, B, C, D  
(if programmed)  
– 17 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Using the Keyswitch  
Using the Keyswitch  
Your system may be equipped with a keyswitch for use when arming and disarming.  
Red and green lights on the keyswitch plate indicate the status of your system as  
follows:  
Gr een Ligh t: Lights when the system is d isa r m ed a n d r ea d y to be armed (no  
open zones). If the system is disarmed and the green light is off, it  
indicates the system is not ready (one or more zones are open).  
R ed Ligh t:  
Lights or flashes when system is armed in AWAY or STAY mode.  
See your installer for the meanings of the lit red light:  
Lit Steady = system armed AWAY or  
system armed STAY and exit delay has expired  
Flashing = system armed STAY and exit delay timer active  
Rapid flashing = an alarm has occurred (memory of alarm).  
Before arming, close all perimeter doors and windows.  
To a r m in th e AWAY m od e:  
Turn the key to the right for 1/2 second and release.  
Keypads beep twice and the red indicator lights or  
flashes.  
To a r m in th e STAY m od e:  
Turn the key to the right and hold for longer than 1  
second, then release. Keypads beep three times and  
the red indicator lights or flashes.  
To d isa r m th e system :  
Turn the key to the right and release. The red light  
turns off  
– 18 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Disarming and Silencing Alarms  
Using the [OFF] key  
The OF F key is used to disarm the system, silence alarm and trouble sounds, and  
clear alarm memories.  
IMP ORTANT: If you r etu r n a n d th e m a in b u r gla r y sou n d er is on , DO NOT ENTER, but  
CONTACT THE POLICE from a nearby safe location.  
If you return after an alarm has occurred and the main sounder has shut itself off, th e k eypa d w ill  
beep r a p id ly u p on you r en ter in g, in d ica tin g th a t a n a la r m h a s occu r r ed d u r in g you r  
a bsen ce.  
LEAVE AT ONCE, and CONTACT THE POLICE from a nearby safe location.  
Alpha Display:  
1.  
+
1
(Security Code) OFF  
DISARMED  
The READY” indicator light will be lit if all zones  
are secure, and the keypad will emit a single tone to  
confirm that the system is disarmed.  
READY TO ARM  
Fixed-Word Display: READY  
NOTE: If entry delay has started (youve opened the  
entry door), you do not need to press the OFF key;  
simply enter your security code. The system will  
disarm in about 15 seconds after the last digit of the  
code is entered.  
2. To Silence a Burglary Alarm and Clear a Memory of Alarm  
Enter your security code. This disarms the system and silences the alarm (or  
warning tones of a Memory of Alarm).  
Note the zone in alarm on the keypad display, and make that zone intact (close  
door, window, etc.). Now enter the security code plus OFF to clear the keypads  
Mem or y of Ala r m display.  
3. To Silence a Fire Alarm or Carbon Monoxide Alarm and Clear Memory of Alarm  
Simply press the OF F key to silence the alarm. Then enter the secu r ity cod e plus  
OF F sequence to clear the keypad's Mem or y of Ala r m display. See the Fire Alarm  
System section.  
– 19 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Bypassing Protection Zones  
Using the BYPASS Key  
Use this key when you want to arm your system with one or more zones intentionally  
unprotected.  
Ven t Zon es: Your system may have certain windows set as vent” zones, which are  
automatically bypassed if left open when arming the system (you do not need to  
manually bypass them). However, if a vent zone window is closed a fter arming, it  
becomes protected and will cause an alarm if opened again while the system is armed.  
When bypassing zones:  
The system must be disarmed before you can bypass zones.  
Bypassed zones are unprotected and will not cause an alarm if violated.  
The system will not allow fire zones to be bypassed.  
Zones are automatically unbypassed when the system is disarmed.  
Alpha Display:  
1.  
+
6
+ zone numbers (see below)  
(Security Code) BYPASS  
DISARMED  
Enter the 2-digit zone number(s) for the zone(s) to be  
bypassed (e.g., 06, 10, 13, etc.). Single digit zone  
numbers must be preceded by a zero (e.g. 05, 06).  
HIT * FOR FAULTS  
Fixed-Word Display: NOT READY  
2. When finished, the keypad will momentarily display  
a "Bypass" message for each bypassed zone number.  
Wait for all bypassed zones to be displayed.  
Alpha Display:  
DISARMED BYPASS  
READY TO ARM  
Arm the system as usual. When armed, the arming  
message is displayed with ZONE BYPASSED.”  
Fixed-Word Display: BYPASS  
To display bypassed zones prior to arming, enter  
your security code and press the [6] BYPASS key.  
ARMED: STAY  
ZONE BYPASSED  
Typical armed alpha display after  
bypassing zones.  
– 20 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Bypassing Protection Zones  
Quick Bypass  
If programmed, "Quick Bypass" allows you to easily bypass all open (faulted) zones  
without having to enter zone numbers individually. This feature is useful if, for  
example, you routinely leave certain windows open when arming at night.  
Alpha Display:  
1.  
+
6
+ [#]  
(Security Code) BYPASS  
DISARMED  
In a few moments, all open zones will be displayed  
and automatically bypassed. Make sure that only  
those zones that you wish to leave unprotected are  
bypassed, and that there are no other zones  
unintentionally left open.  
HIT * FOR FAULTS  
Fixed-Word Display: NOT READY  
2. Wait for all bypassed zones to be displayed, then arm  
Alpha Display:  
the system as desired.  
DISARMED BYPASS  
READY TO ARM  
Ask your installer if "Quick Bypass" is active for your  
system, and if so, check here:  
Fixed-Word Display: BYPASS  
– 21 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chime Mode  
CHIME mode alerts you to the opening of a perimeter door or window while the  
system is disarmed. When Chime mode is activated:  
Three tones sound at the keypad whenever a perimeter door or window is opened.  
Interior zones do not produce a tone when they are faulted.  
Pressing the R E ADY key will display the open protection points.  
Chime mode can be used only while the system is disarmed.  
Alpha Display:  
To tu r n Ch im e Mod e on :  
+
9
(Security Code) CHIME  
The CHIME message will appear. Perimeter zones  
will cause a tone when faulted.  
DISARMED CHIME  
READY TO ARM  
Fixed-Word Display: CHIME  
To tu r n Ch im e Mod e off:  
+
9
again (CHIME message disappears)  
(Security Code) CHIME  
Voice Ch im e: You can set the Voice Keypads (if installed) to announce faulted  
(opened) entry/exit or perimeter zones whenever normal Chime mode is on.  
To tu r n Voice Ch im e Mod e on or off:  
#
+
0
+
2
+
4
(normal Chime mode must be on first)  
When Voice Chime is on, faulted zones cause a voice status announcement, chime  
and display. When off, the sounder still provides chime if normal Chime mode is on.  
– 22 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Date and Time  
Viewing the Current Date and Time  
The master users can view the system time and date setting on alpha keypad.  
Other users can view the date/time if a function key has been programmed to do so.  
Alpha Display:  
+[#] + [6] [3]  
(Master Code)  
DISARMED  
OR, press the function key (A, B, C, or D) for viewing  
current date and time, if programmed.  
READY TO ARM  
A typical time/date display is shown.  
TIME/DATE  
12:05AM_05/09/00  
SAT  
The display will remain on for about 30 seconds or until  
a key is pressed.  
“A”  
“B ”  
“C ”  
“D ”  
If one of the above keys has been programmed for the date/time  
display feature, place a check mark in the box beneath that key.  
Setting the Date and Time  
NOTE: All partitions must be disarmed before date/time can be set.  
You can set the time and date by doing the following:  
Alpha Display:  
1.  
+[#] + [6] [3]  
(Master Code)  
DISARMED  
READY TO ARM  
2. Press [] when the time/date is displayed.  
TIME/DATE  
04:04PM 10/17/00  
Current time display  
SAT  
A cursor appears under the first digit of the hour.  
To move cursor ahead, press []. To go back, press [#].  
Enter the 2-digit hour setting.  
Enter the 2-digit minute setting.  
Press [1] for PM or [2] for AM.  
Enter the last two digits of the current year.  
Enter the 2-digit month setting.  
Enter the 2-digit day setting.  
TIME/DATE  
04:04P2000/10/17  
Time/date editing display  
SAT  
3. To exit, press [] when cursor is at the last digit, or  
wait 30 seconds.  
– 23 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Panic Keys  
Using Panic Keys  
Your system may have been programmed to use special keys to manually activate  
emergency (panic) functions as follows:  
Th is F u n ction  
Sen d s th is sign a l*  
With Th is Sou n d in g…  
Silent Alarm  
silent alarm  
no audible alarm or change in normal  
display to indicate that a silent alarm  
has been initiated.  
Audible Alarm  
audible alarm  
a loud, steady alarm at keypad(s) and  
at any external sounders that may be  
connected.  
Personal Alarm  
Fire Alarm  
auxiliary alarm  
fire alarm  
steady alarm sound at keypad(s), but  
not at external bells or sirens.  
temporal (pulsing) sound at external  
bells and sirens.  
*All panic functions send signals to the Central Monitoring Station, if connected.  
To a ctiva te a P a n ic F u n ction :  
Alpha Display:  
Press and hold down for at least 2 seconds whichever  
lettered key on the keypad has been programmed for  
the desired emergency function.  
DISARMED  
READY TO ARM  
Fixed-Word Display: READY  
OR  
Typical Panic Alpha Display:  
Press both keys of the assigned key pair at the same  
time.  
ALARM 99  
Fixed-Word Display: 99 and ALARM  
ARMED READY  
A
PRESS BOTH KEYS  
OF DESIRED PAIR  
ARMED READY  
ZONE 95  
R
AT THE SAME TIME  
AWAY  
STAY  
1
4
7
2
3
6
9
#
B
5
ZONE 99  
R
ZONE 95  
ZONE 96  
8
0
AWAY  
1
4
7
2
5
8
0
3
6
9
#
PAGE  
STAY  
C
FA560  
ZONE 96  
PAGE  
FA560  
ZONE  
99  
D
Lettered Panic Keys  
Panic Key Pairs  
See your installer and use the chart provided in the Fea tu r es P r ogr a m m ed in You r  
System section to note the functions that have been programmed for your system.  
– 24 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Macro Key Programming & Usage  
About Macro Keys  
The A”, “B, “C” or “D” keys can be used to automatically activate a series of  
commands of up to 16 keystrokes, if programmed for this function. These keystrokes,  
as a group, are called macros” and are stored in the system's memory.  
Typical macro functions can include:  
- Arming sequences: STAY, Night-STAY, INSTANT, or AWAY  
- Bypassing particular zone(s)  
- Activating relay(s) for turning on (or off) lights, fans, etc.  
Up to four (FA168CPS) or two (FA148CP) macros can be assigned – but no  
more than one macro to a key.  
Macros can be activated only by users with authority levels authorized to  
perform the macros function.  
NOTE: The installer must activate the desired function key before macros can be  
assigned. See the chart at the back of this manual for the key(s) assigned for macros.  
Alpha Displays:  
1.  
+ [#] + [6] + [6]  
(Master Code)  
DISARMED  
READY TO ARM  
2. Enter the macro number (1-4 for FA168CPS; 1-2 for  
FA148CP) to be programmed at the Select Macro?”  
prompt. Remember, only one macro can be assigned  
to each key.  
SELECT MACRO  
1-4  
0
3. If a macro has been previously defined, the  
keystrokes are shown on the bottom line of the  
display, otherwise the display is blank.  
MACRO DISPLAY  
To exit this mode (and keep the existing macro  
definition), press any key except the [] key. The  
system returns to normal mode.  
To define a macro for the selected key, press [] and  
continue with the next prompt.  
Enter the first of the series of desired commands, (do  
not include your master code), then press/hold the D”  
key for at least two seconds to complete the first  
command. This key terminates each command, and  
appears as an F” in the keypad display.  
MACRO PGM  
– 25 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Macro Key Programming & Usage (cont.)  
The keypad beeps to acknowledge your input and displays the command you  
entered (followed by F).  
4. Enter the next command, followed by press/holding the D” key for at least two  
seconds. The keypad beeps and displays the keystrokes entered so far.  
5. Repeat until all the desired commands (up to 16 characters including the Fs) have  
been entered.  
Be sure to check your keystrokes before continuing. If you made a mistake, you  
must start over.  
6. To exit, press/hold the D” key for at least two seconds. The display returns to  
system status and indicates system is ready.  
Example of Macro Programming  
Typical Macro Alpha Display:  
Suppose you want to (1) bypass the two upstairs  
window zones, then (2) turn on an exterior light, and  
then (3) arm the security system in the AWAY mode.  
The procedures in the table that follows show you how  
MACRO PGM  
6 0 2 0 3 F # 7 0 1 F 2 F  
you would program this macro:  
Function  
Keystrokes Required  
Keypad Display  
1. Bypass zones 02 & 03  
Press BYPASS [6] key, then  
2-digit zone numbers 02 & 03.  
Press the D” key for at least 2 seconds.  
6 0 2 0 3  
2. Insert terminator.  
6 0 2 0 3 F  
6 0 2 0 3 F # 7 0 1  
3. Turn light on  
(device 01).  
Press [#] and 7 keys for device ON, and  
[01] key for selecting device 1.  
4. Insert terminator.  
Press the D” key for at least 2 seconds.  
6 0 2 0 3 F # 7 0 1 F  
6 0 2 0 3 F # 7 0 1 F 2  
6 0 2 0 3 F # 7 0 1 F 2 F  
5. Arm system AWAY  
6. Insert terminator.  
7. Exit macro mode  
Press AWAY [2] key.  
Press the D” key for at least 2 seconds.  
Press the D” key again.  
Using a Programmed Macro Key  
1. Press the Macro key programmed for the desired  
DISARMED  
READY TO ARM  
series of commands for at least 2 seconds. The Enter  
User Code” prompt appears. The prompt remains  
displayed for up to 30 seconds.  
2. Enter your 4-digit security code.  
ENTER USER CODE  
* * * *  
The programmed macro sequence begins  
automatically after the user code is entered.  
– 26 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Using Device Commands  
About Device Commands  
Your system may be set up so that it can control certain lights or other devices.  
Some devices may be automatically turned on or off by the system.  
You may be able to override automatically controlled devices using the  
commands described below.  
Some devices can be manually turned on or off using the commands described  
below.  
See your installer for a list of devices that may be set up for your system. A list  
of these devices is provided at the back of this manual for you to fill out.  
To Activa te Devices:  
+ [#] + [7] + 2-digit device number  
Alpha Display:  
DISARMED  
READY TO ARM  
(Security Code)  
Devices associated with that device number activate.  
Fixed-Word Display: READY  
To Dea ctiva te Devices:  
+ [#] + [8] + 2-digit device number  
(Security Code)  
Devices associated with that device number deactivate.  
– 27 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Paging Feature  
About Automatic Paging  
Your system may be set up to automatically send alert messages to several pagers (up  
to four for FA168CPS, up to two for FA148CP) as certain conditions occur in your  
system.  
The following events can be programmed by your installer to be sent to the pagers:  
arming and disarming, alarms, and trouble conditions. (reports when  
arming/disarming from a keypad using a security code; auto-arming/disarming,  
arming with assigned button, and keyswitch arming do not send pager messages.)  
You can also program the system to send an automatic pager message to alert you  
in the event that someone has not arrived home (disarmed the system) within a  
defined period of time (see the Sch ed u lin g section for details on programming a  
latch key report).  
Your installer programs the pager phone numbers and reporting events.  
The pager message consists of a 7-digit system status code that indicates the type of  
condition that has occurred.  
An optional, predefined 16-digit character string can precede the 7-digit system  
status code; these characters can consist of a PIN no., subscriber account no., or any  
additional data that you may wish to have sent to the pager.  
The pager display format is as follows:  
3-digit Event Code  
Optional 16 digits  
È
È
Å 1-digit Partition No. + 3-digit Zone No. or User No.  
AAAAAAAAAAAAAAAA BBB CCCC  
A = B =  
C =  
Optional 16-digits for A 3-digit code that  
A 1-digit Partition number plus a 3-digit Zone or User  
Account numbers,  
PIN numbers, or any  
other data;  
programmed by the  
installer, if required.  
describes the event number, depending on the type of event that has  
that has occurred  
in your system  
(see for event  
occurred, where:  
alarms and troubles display zone number  
arming/disarming (opens/closes) display user number  
codes table below)  
The 3-digit Event Codes (BBB) that can be displayed are:  
911 =  
Ala r m s.  
811 =  
Tr ou bles.  
101 =  
Op en  
102 =  
Close  
The 4-digit number  
(CCCC) following this  
code is the partition no. code is the partition no.  
and zone no. that  
caused the alarm.  
The 4-digit number  
(CCCC) following this  
(syst em d isa r m ed ).  
The 4-digit number  
(CCCC) that follows  
this code is the  
partition no. and user  
no. that disarmed the  
system.  
(syst em a r m ed ).  
The 4-digit number  
(CCCC) that follows  
this code is the  
partition no. and user  
no. that armed the  
system.  
and zone no. that  
caused the trouble.  
Ex. 1. 9 1 1 – 1 0 0 4 = R eporting of an alarm (911) caused by a fault on zone 4 on Partition 1 (1004).  
Ex. 2. 1 0 2 – 2 0 0 5 = Reporting of a closing–system arming (102)– by user 5 in Partition 2 (2005).  
– 28 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Paging Feature  
Manual Paging  
Your system may be set up so you can manually send a message to up to four  
(FA168CPS) or two (FA148CP) pagers.  
Your installer programs the paging function key and the pager phone numbers.  
Pressing the paging keys sends the message 9 9 9 – 9 9 9 9  
to the selected pager.  
This message could mean call home, “call your office, or any other prearranged  
meaning.  
See the Paging chart at the back of this manual for details of the paging setup for  
your system.  
1. Press and hold the programmed Paging Key for at  
least 2 seconds (wait for beep), then press the pager  
number (1-4)* representing the pager intended to  
receive the message.  
Alpha Display:  
DISARMED  
READY TO ARM  
2. The recipient, on seeing the 999–9999 message, will  
understand the prearranged meaning of this signal.  
Fixed-Word Display: READY  
* If no number is pressed, the message is sent to pager 1.  
Pagers 1-4 for FA168CPS series; 1-2 for FA148CP series  
999-9999  
Pager Display  
Latch Key Paging  
You can program a schedule that causes a pager report to be sent if the system is not  
DISARMED by the scheduled time (see Sch ed u lin g section, event 03). For example,  
a working parent might want a message to be sent to a pager if their child did not  
arrive home from school and disarm the system by a certain time.  
If programmed, the message that is sent is: 7 7 7 – 7 7 7 7  
.
– 29 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Security Codes & Authority Levels  
About Security Codes  
Your installer assigned a master code that is used to perform all system functions.  
In addition, you can assign different security codes for use by other users (FA168CPS  
provides 47 additional codes; FA148CP provides 31 additional codes).  
Only the System Master and Partition Master can assign security codes to users.  
Users are identified by 2-digit user numbers and are pre-assigned to either  
partition 1 or partition 2 (FA168CPS).  
Only the System Master can change user partitions.  
In addition to a security code, each user is assigned various system attributes.  
Security codes can be used interchangeably within a partition when performing  
system functions (a system armed with one user's code can be disarmed by another  
user's code), with the exception of the Guest code and Arm Only code described  
below.  
Security code programming involves these steps:  
1. Choose a user number from the set of users assigned to the partition in which  
the user will be operating, and assign a 4-digit security code.  
2. Assign an authority level to that user.  
3. Assign other attributes as necessary (see attributes on the next page).  
NOTE: The factory settings are designed to meet most normal user situations.  
Therefore, the only step you usually need to do when adding users is assign a user  
number (from the partitions pre-assigned user numbers) and a security code.  
Authority Level Definitions  
Authority levels define the system functions a particular user can/cannot perform.  
Level Title  
Exp la n a tion  
N/A  
System Master  
(default = 1234)  
Reserved for user 02; Can perform all system functions and assign codes in  
both partitions; can change its own code as follows:  
Master code + [8] + 02 + new master code + new master code again  
0
Standard User  
Can only perform security functions in assigned partition.  
Cannot perform system functions reserved for the master user.  
1
2
Arm Only  
Guest  
Can only arm the system. Cannot disarm or do other functions.  
Can arm the system in assigned partitions, but cannot disarm the system  
u n less the system was armed with this code. This code is typically assigned to  
someone (e.g., babysitter or cleaner) who has a need to arm/disarm the system  
only at certain times. The user of this code should n ot use the Quick Arming”  
feature.  
3
4
Duress Code  
Intended for use when you are forced to disarm or arm the system under  
threat. When used, the system will act normally, but can silently notify the  
Central Monitoring Station of your situation, if that service has been provided.  
Partition Master (FA168CPS) Can do everything a standard user can do, and  
can assign security codes to users in their partition.  
– 30 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Security Codes & Authority Levels (Cont.)  
How to Assign Security Codes and Attributes  
The following lists the various command strings for adding security codes and attributes.  
R efer to th e User Setu p ch a r t a t th e b a ck of th is m a n u a l for fa ctor y  
a ssign m en ts of u ser a tt r ib u tes a n d to k eep a r ecor d of u ser p r ogr a m m in g.  
NOTE: Partition Master codes (FA168CPS only) apply only to those user numbers  
previously assigned (by the system master/installer) to the partition masters partition.  
Ad d Secu r ity Cod e: System/Partition Master code + [8] + user no. + new user’s security code  
(Users 03/33 are preset  
to partition programmers,  
but can be changed.)  
User 01 = installer  
User 02 = master  
The Keypad beeps once to confirm that new user was added.  
User 03 = partition 1 master  
User 33 = partition 2 master  
Delete Secu r ity Cod e: System/Partition Master code + [8] + [user no.] + [#] [0]  
The user code and all attributes* programmed for this user number,  
including any associated RF keys, are erased from the system.  
(*except assigned partition)  
Au th or ity Level:  
System/Partition Master code + [8] + [user no.] + [#] [1]+ auth. level  
Factory Assignments:  
users 04-32/34-49 = 0  
users 03/33 = 4  
Authority Levels (see definitions on previous page):  
0 = standard user  
1 = arm only  
2 = guest  
3 = duress  
4 = partition master (FA168CPS only)  
Access Gr ou p :  
System/Partition Master Code + [8] + [user no.] + [#] [2]+ group (1-8)  
Factory Assignments: none  
You can assign users to a group, then set an access schedule that  
defines the times this group of users can operate the system. The  
system ignores these users outside the scheduled times.  
User s P a r tition :  
System Master Code + [8] + [user no.] + [#] [3] + [0] + partition(s) + [#]  
(FA168CPS only)  
This command assigns the partitions the user can access. If more  
than one, enter partition numbers sequentially, then press [#] to end.  
E.g., master code + [8] + [user no.] + [#] [3] + [0] + [1] [2] + [#] gives  
the user access to partitions 1 and 2 and the common partition.  
Partition Entries: 1 = partition 1 and common  
Factory Assignments:  
Part. 1 = users 03-32  
Part. 2 = users 33-49  
2 = partition 2 and common  
3 = common partition only  
R F User Nu m b er :  
Master/Part. Prog. Code + [8] + [user no.] + [#] [4]+ zone no.  
Factory Assignments: none  
Use this command to assign a wireless button device (keyfob) to this  
user (keyfob must be enrolled in system first; see installer).  
Zone number: enter the zone number assigned to a button on the  
keyfob that will be used for arming/disarming by this user.  
P a ger On /Off:  
Master/Part. Prog. Code + [8] + [user no.] + [#] [5] + 0 or 1  
Factory Assignments:  
users 01-49 = 1 (on)  
You can program a user so that a message is sent to a pager  
whenever this code is used to arm or disarm the system.  
Paging On/Off: 1 = allow paging; 0 = no paging for this user  
– 31 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Accessing Other Partitions (FA168CPS)  
(GOTO Command and Multi-Partition Arming)  
About Accessing Partitions  
Each keypad is assigned a default partition for display purposes, and will show only  
that partition's information.  
If the user is authorized, a keypad in one partition can be used to perform  
system functions in the other partition by using the GOTO command. Refer to  
the GOTO section.  
If the user is authorized, that user can arm other partitions. Refer to the Multi-  
Partition Arming section.  
The following table shows the relationship of the keypads in each partition when  
system is armed and disarmed.  
P ARTITION 1  
P ARTITION 2  
COMMON ZONE  
(LOBBY, etc.)  
Ar m in g  
Sta te  
Keyp a d  
Sta tu s  
Ar m in g  
Sta te  
Keyp a d  
Sta tu s  
Ar m in g  
Sta te  
Keyp a d  
Sta tu s  
Disarmed  
Partition 1  
Disarmed  
Partition 2  
Disarmed Common Zone  
Con d it ion 1  
Con d it ion 2  
Con d it ion 3  
Ö
Ö
Ö
On ly  
On ly  
On ly  
Disarmed Partition 1 and  
Common Zone  
Armed  
Partition 2  
Disarmed Common Zone  
On ly  
On ly  
Armed  
Partition 1  
Disarmed Partition 2 and Disarmed Common Zone  
On ly  
Common Zone  
On ly  
Armed  
Partition 1  
Armed  
Partition 2  
Armed  
Common Zone  
Con d it ion 4  
Ö
On ly  
On ly  
On ly  
When both partitions are disarmed, the keypad in each partition displays zone  
status for its partition only. The common zone keypad shows the status in that  
zone only. See Condition 1 above.  
When partition 1 is disarmed and partition 2 is armed, the keypad in partition 1  
shows the status of partition 1 a n d the common zone. Partition 2 will display the  
status of partition 2 on ly. See Condition 2 above.  
When partition 1 is armed and partition 2 is disarmed, the keypad in partition 1  
shows the status of partition 1 on ly. Partition 2 will display the status of partition  
2 a n d the common zone. See Condition 3 above.  
As long as any one of the two partitions is disarmed, the common zone will always  
be disarmed. The common zone will be armed only when both partition 1 and 2 are  
armed. See Condition 4 above.  
– 32 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Accessing Other Partitions (Continued)  
Using the GoTo Command  
If the user is authorized, a keypad in one partition can be used to perform system  
functions in the other partition by using the GOTO command.  
You must use an Alpha keypad to access another partition.  
Keypads automatically return to their original partition after 30 seconds  
with no keypad activity.  
Alpha Display:  
1.  
+ [] + partition number (0,1,2,3)  
(Security Code; only applies if user has access to other partitions)  
1 DISARMED  
READY TO ARM  
0 = return to keypads original partition.  
1 = partition 1; 2 = partition 2; 3 = common zone  
The keypad beeps to confirm the partition change.  
Fixed-Word Display: Green LED lit  
Alpha Display:  
2. The keypad remains in the new partition until  
directed to go to another partition, or until it  
automatically returns to the original partition.  
2 DISARMED  
READY TO ARM  
The active partition number is displayed in the upper  
left portion of screen, if the option is programmed.  
Fixed-Word Display: Green LED lit  
Multi-Partition Arming  
Some users can be given Multi-Partition arming ability by being assigned to both  
partitions when programming user attributes.  
When attempting to arm multi-partitions:  
You must use an Alpha keypad.  
The system arms only if all partitions are ready to arm.”  
If any partition is “not ready,” the system does not arm at all.  
You can use the GOTO command to bypass open zones before arming.  
If any partition is already armed when global arming is attempted, that  
partition remains in its existing armed state.  
Alpha Display:  
+ [0] + arm command (see list below)  
(Security Code)  
1 DISARMED  
Multi-Partition Arming Commands  
2 = arms all partitions AWAY  
3 = arms all partitions STAY  
READY TO ARM  
Fixed-Word Display: Green LED lit  
33 = arms all partitions NIGHT-STAY  
4 = arms all partitions MAXIMUM  
7 = arms all partitions INSTANT  
1 = disarms all partitions  
– 33 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Accessing Other Partitions (Continued)  
Common Zone Operation  
Your system may have been set up to use a common zone, which is  
an area shared by users of both partitions, such as a foyer or lobby.  
If so, please note the following:  
Ask your installer if a  
"common zone" was  
assigned. If so, check  
this box  
The common zone will sound and report alarms only when b oth  
partitions are armed. If only one partition is armed, the system  
ignores faults on the common zone.  
Either partition may arm its system if the common zone is  
faulted, but once armed, the other partition w ill n ot be able to  
arm unless the common zone is first bypassed or the fault is  
corrected.  
Faults on the common zone are displayed on common partition  
keypads, and will also appear on another partitions keypad when  
the alternate partition is armed.  
Either partition can clear and restore the common zone after an  
alarm.  
Entry/exit time for the common zone is the same as for partition 1.  
– 34 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Scheduling  
About Scheduling  
The system provides end-user schedules (programmable by master/installer only),  
which can control various types of events.  
Each schedule causes a defined event to start and stop (when appropriate) at a  
specified time.  
Schedules can be set to automatically repeat at various intervals.  
Schedules can be set for random starting, if desired.  
FA168CPS provides up to 16 user schedules; FA148CP provides up to 4 user schedules.  
Creating Schedules  
Alpha Displays:  
1.  
+ [#] + [6] [4]  
1 DISARMED  
READY TO ARM  
(Master Code)  
2. Enter a 2-digit schedule number from:  
01-16 (FA168CPS) or 01-04 (FA148CP).  
Press [] to continue.  
ENTER SCHED NO.  
00=QUIT  
00  
3. Enter the desired 2-digit event number from the  
following list.  
ENTER EVENT  
CLEAR EVENT 00  
00 = clear the scheduled event  
01 = turn a programmed output on or off  
(see Usin g Device Com m a n d s section for a list of output device numbers used  
in your system)  
02 = set a user access schedule for one or more users  
(see Secu r ity Cod es section for an explanation of access groups)  
03 = send a latch-key” report to a pager if the system is not disarmed by a specified  
time; message sent is 777-7777.”  
04 = automatically arm the system in STAY mode at a specified time  
05 = automatically arm the system in AWAY mode at a specified time  
06 = automatically disarm the system at a specified time  
07 = Display the word REMINDER” at a specified time (if selected, the keypad  
beeps every 30 seconds beginning when the word REMINDER” is first  
displayed, and the display alternates with the normal keypad display about  
every 4-5 seconds. To stop the beeps and cancel the display once it starts,  
simply press any key).  
Press [] to continue.  
4. For event number 01,” enter the output number  
RELAY NUMBER  
associated with this schedule.  
00  
Otherwise, this prompt is skipped.  
Press [] to continue to the Start” prompt shown on  
the next page.  
– 35 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Scheduling (continued)  
5. For event number 02,” enter the access group  
number. Otherwise, this prompt is skipped.  
Press [] to continue to the Start” prompt below.  
GROUP NUMBER  
PARTITION  
X
X
6. For event numbers 03-07,” enter the partition  
number to be armed or disarmed.  
0 = arm all; 1 = partition 1; 2 = partition 2;  
3 = arm common  
Otherwise, this prompt is skipped.  
Press [] to continue to the Start” prompt.  
7. Enter the events start time and days of week.  
Hour = 00-12; minute = 00-59  
START  
SMTWTFS  
AM = 0; PM = 1  
HH:MMAM 1000000  
Days = Position the cursor under the desired days  
using the [] key to move forward, then press 1” to  
select the day.  
Press [] to continue.  
8. If applicable, enter the events stop time and days of  
week (applies only to event numbers 01, 02, and 03).  
Refer to step 7 for available entries.  
STOP  
HH:MMAM 1000000  
SMTWTFS  
Press [] to continue.  
9. Enter the desired repeat option.  
0 = no repeat  
REPEAT OPTION  
0-4  
X
1 = repeat schedule weekly  
2 = repeat schedule biweekly (every other week)  
3 = repeat schedule every third week  
4 = repeat schedule every fourth week  
e.g., To make a schedule that happens everyday you  
would select all days with a repeat count of 1. To  
make a schedule that runs for one week then stops,  
select everyday with a repeat count of 0.  
Press [] to continue.  
10. For event number 01 (output on/off), select the  
desired randomize option. 0 = no; 1 = yes  
If selected, the schedule times will vary within 60  
minutes of the hour” time. For example, if a  
schedule is set to start at 6:15pm, it will do so the  
first time 6:15pm arrives, but on subsequent days it  
will start anytime between 6:00 and 6:59 p.m.  
Press [] to continue.  
RANDOMIZE  
0=NO 1=YES  
X
– 36 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Event Logging Procedures  
About Event Logging  
The system records various events in a history log, which can be viewed by the master  
user using an Alpha Display keypad.  
The Event Log holds up to 100 (FA168CPS) or 50 (FA148CP) events.  
Events are displayed in chronological order, from most recent to oldest.  
When the log is full, the oldest event is replaced by the logging of any new event.  
Viewing the Event Log  
Alpha Displays:  
1.  
+ [#] +  
6
+
0
(Master Code)  
DISARMED  
READY TO ARM  
2. The system displays the most recent event as follows:  
event number, type of event (see table of codes below),  
zone or user number (depending on type of event)  
partition in which event occurred, time and date of  
the events occurrence.  
001 E441 U001 P1  
12:34AM 01/02/00  
3. Pressing [] displays previous events (back in time).  
Pressing [#] displays events forward in time.  
4. Exit by pressing any key other than [] or [#].  
Understanding the Type of Event Displayed  
If the event code is preceded by an E (as in the above display), it means that the  
event is new and ongoing; if preceded by an R, it means the event has been restored.  
See your installer for more detailed information regarding the meanings of these codes  
Code - Definition  
Code - Definition  
Code - Definition  
Code - Definition  
110 - Fire Alarm  
162 - Carbon Monoxide  
380 - Global Trouble, Trouble  
Day/Night  
442 - Keyswitch Arm/Disarm STAY  
121 - Duress  
122 - Alarm, 24-hour Silent  
301 - AC Power  
302 - Low System Battery/Batt  
Test Fail  
381 - RF Supervision Trouble  
382 - Supervsn Aux Wire Zone  
459 - Recent Closing  
570 - Bypass  
123 - Alarm, 24-hour Audible  
131 - Alarm, Perimeter  
132 - Alarm, Interior  
305 - System Reset (Log only)  
321 - Bell/Siren Trouble  
333 - Trble, Exp. Mod. Supervsn 393 - Clean Me  
341 - Trble, ECP Cover Tamper 401 - Disarmed, Armed AWAY,  
Armed MAXIMUM  
383 - RF Sensor Tamper  
384 - RF Sensor Low-battery  
601 - Manual Triggered Dialer Test  
602 - Periodic Test  
606 - AAV to Follow  
134 - Alarm, Entry/Exit  
607 - Walk Test Entered/Exited  
135 - Alarm, Day/Night  
137 - Alarm, Tamper  
344 - RF Receiver Jam  
403 - Sched. Arm/Disarm  
AWAY  
406 - Cancel by User  
623 - Event Log 80% Full  
351 - Telco Line Fault  
625 - Real-Time Clock was Changed  
(log only)  
143 - Alarm, Expansion Module  
353 - Long Range Radio Trble  
407 - Remote Arm/Disarm  
627 - Program Mode Entry (log  
only)  
145 - ECP Module cover tamper 373 - Fire Loop Trouble  
408 - Quick Arm AWAY  
409 - Keyswitch Arm/Disarm  
AWAY  
628 - Program Mode Exit (log only)  
642 - Latch Key (log only)  
146 - Silent Burglary  
374 - Exit Error Alarm  
150 - Alarm, 24-Hr Aux/Mon zn  
441 - Disarm/Arm/ Quick-Arm  
STAY/INSTANT  
750 -789 - Configurable Zone Type  
report codes  
– 37 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Testing the System (To Be Conducted Weekly)  
About Testing the System  
Test mode allows each protection point to be checked for proper operation.  
The keypad sounds a single beep about every 30 seconds as a reminder that the  
system is in the Test mode.  
Alarm messages are not sent to your Central Station while Test mode is on.  
Alpha Displays:  
1 Disarm the system and close all protected windows,  
doors, etc. The READY indicator light should come  
on if all zones are intact (i.e., all protected windows,  
doors, etc. are closed.  
DISARMED  
READY TO ARM  
2.  
+
5
then [0] (walk)  
1 = DIAL, 0 = WALK  
(Master Code)  
TEST  
The Dial test (option 1) is intended for the installer  
and should not be used unless directed to do so by  
your Security System Representative.  
3. Listen. The external sounder should sound for about 1  
second then turn off. If the sounder does not sound,  
CALL FOR SERVICE. The Test in Progress” display  
appears only on the keypad that started the test.  
TEST IN PROGRESS  
4. Fault zones. Open each protected door and window in turn and listen for three  
beeps from the keypad. Identification (zone number or zone description) of each  
faulted protection point should appear on the display. The display clears when the  
door or window is closed.  
5. Walk in front of any interior motion detectors (if used) and listen for three beeps.  
The identification of the detector should appear on the display when it is activated.  
The display clears when no motion is detected.  
Note that if wireless motion detectors are used, there is a 3-minute delay between  
activations. This is to conserve battery life.  
6. Test all smoke detectors, following the manufacturer's instructions. The  
identification of each detector should appear on the display when each is activated.  
If a problem is experienced with any protection point (no confirming sounds, no  
display), call for service immediately.  
When all protection points have been checked and are intact (closed), there should  
be no zone identification numbers displayed on the keypad.  
7. Exit test mode:  
+ [ 1 ]  
(Security Code)  
If the test mode is inadvertently left active, it automatically turns off after 4 hours.  
During the final five minutes, the keypad will emit a double beep every 30 seconds.  
– 38 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Trouble Conditions  
"Check" and  
The word CHECK on the keypad's display, accompanied by a  
"Battery" Displays  
"beeping" at the keypad, indicates a trouble condition in the system.  
To silen ce th e b eep in g for th ese con d ition s, p r ess a n y k ey.  
1. A d isp la y of "CH ECK" a n d on e or m or e zon e n u m b er s  
indicates that a problem exists with the displayed zone(s) and  
requires your attention. Determine if the zone(s) displayed are  
intact and make them so if they are not. If the problem has been  
corrected, the display can be cleared if you enter the OFF  
sequence (security code plus OFF key) twice. If the display  
persists, CALL FOR SERVICE.  
Note: A display of CHE CK 70 on Alpha Display keypads  
indicates that the wiring connection to the external sounder is  
at fault (opened or shorted), and you should CALL FOR  
SERVICE. See BELL FAILURE” on next page. A display of  
CHE CK 90 indicates that RF interference may be impeding the  
operation of wireless sensors* in the system. See R cvr J a m ”  
on next page.  
2. If th er e a r e w ir eless sen sor s* in you r system , the CHECK  
condition may also be caused by some change in the  
environment that prevents the wireless receiver from receiving  
messages from a particular sensor. CALL FOR SERVICE if this  
occurs.  
* Not all systems  
use wireless  
sensors.  
IF YOU CANNOT COR R ECT A "CHECK" DISP LAY,  
CALL F OR SER VICE.  
TYP ICAL "CHECK" DISP LAYS  
AC  
06  
C H E C K 0 6  
B E D R O O M W I N D O W  
CHECK  
ALP HA DISP LAY KE YP AD  
F IXED-WOR D DISP LAY KEYP AD  
– 39 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Trouble Conditions (Continued)  
Words or letters in parentheses ( ) are those that are  
displayed on Alpha Display keypads.  
COMM. F AILUR E  
(or F C)  
Indicates that a failure has occurred in  
the telephone communication portion of  
your system. CALL FOR SERVICE.  
Other Trouble  
Displays  
SYSTE M LO BAT  
(or BAT with no  
zone No.)  
Indicates that a low system battery  
condition exists. Display is  
accompanied by "beeping"* at the  
keypad. If this condition persists for  
more than one day (with AC present),  
CALL FOR SERVICE.  
* Any beeping” that  
accompanies a trouble  
display can be stopped  
by depressing any key  
on the keypad or by  
entering an OFF  
sequence (code + OFF)  
LO BAT  
Indicates that there is a low battery  
condition in the wireless transmitter**  
number displayed (00 is RF keypad).  
+ zone descriptor  
(or BAT with  
zone No.)  
** Not all systems use  
wireless sensors.  
*
Accompanied by a single "beep" (about  
once every 30 seconds) at the keypad.  
Either replace the battery yourself, or  
CALL FOR SERVICE. If the battery is  
not replaced within 30 days, a CHECK  
display may occur.  
R cvr J a m  
(or CHE CK 90)  
Wireless part of the system is experiencing  
RF interference which may impede  
reception from wireless sensors.**  
Indicates a communication problem  
between the control and a connected  
device (e.g., RF receiver, zone expander)  
where the xx” indicates the device  
address. CALL FOR SERVICE.  
ALAR M 1xx  
F AULT 1xx  
CHE CK 1xx  
(or 91)  
Indicates that the control is on-line with  
the Central Monitoring Station's remote  
computer.  
MODE M COMM  
(or CC)  
The control will not report system  
activity while on-line. Wait a few minutes  
the display should disappear.  
BELL F AILUR E  
(or CHE CK 70)  
Indicates that the wiring connection to  
the external sounder is at fault (open or  
shorted). Accompanied by beeping” at  
the keypad. CALL FOR SERVICE.  
– 40 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Trouble Conditions (Continued)  
Other Trouble  
Displays  
(Continued)  
AC LOSS  
(or NO AC)  
The system is operating on battery power  
only due to an AC power failure.  
If only some lights are out on the premises,  
check circuit breakers and fuses and  
reset or replace as necessary.  
If AC power cannot be restored and a  
low system battery” message appears  
(see previous page), CALL F OR  
SER VICE.  
If this message remains displayed for more  
than 1 minute, system is disabled. CALL  
F OR SER VICE.  
Bu sy-Sta n d by  
(or d I)  
OP EN CIRCUIT  
(or OC)  
The keypad is not receiving signals from  
the control. CALL FOR SERVICE.  
Lon g R n g Tr b l  
(or b F )  
If part of your system, back-up Long  
Range Radio communication has failed.  
CALL FOR SERVICE.  
TELCO F AULT  
(or CHE CK 94)  
The telephone line has a problem.  
CALL FOR SERVICE.  
If th er e is n o k eyp a d d isp la y a t a ll, a n d th e R E ADY in d ica tor  
is n ot lit, operating power (from AC and back-up battery) for the  
system has stopped and the system is inoperative. CALL F OR  
SERVICE.  
Total Power Failure  
In The Event Of Telephone Operational Problems  
In the event of telephone operational problems, disconnect the control from the phone line by  
removing the plug from the phone wall jack. We recommend that your installer demonstrate this  
disconnection on installation of the system. Do not attempt to disconnect the phone connection  
inside the control. Doing so will result in the loss of your phone lines. If the regular phones work  
correctly after the control has been disconnected from the phone wall jack, the control has a  
problem and you should immediately call for service. If upon disconnection of the control, there is  
still a problem on the phone line, notify the Telephone Company that they have a problem and  
request prompt phone repair service. The user may not under any circumstances attempt any  
service or repairs to the security system. Repairs must be made only by authorized service (see  
the LIMITED WARRANTY statement for information on how to obtain service).  
– 41 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Maintaining Your System  
The components of your security system are designed to be as  
Taking Care of  
Your System  
maintenance-free as possible. However, to make sure that your system  
is in reliable working condition, do the following:  
1. Test your system weekly.  
2. Test your system after any alarm occurs.  
Silencing Low  
Battery Warning  
Tones at the  
Keypad  
You can silence the keypads warning tones by pressing the OFF key,  
but the keypad's low battery message display will remain on as a  
reminder that you have a low battery condition in one or more of your  
wireless sensors. When you replace the weak battery with a fresh one,  
the sensor sends a "good battery" signal to the control as soon as the  
sensor is activated (opening/closing of door, window, etc.), causing the  
low battery display to turn off. If the sensor is not activated, the display  
will automatically clear within approximately 1 hour.  
Each wireless sensor in your system has a 9-volt or 3-volt battery. The  
system detects a low battery in wireless sensors, including smoke  
detectors, the personal emergency transmitter, and the portable  
wireless keypad and displays a low battery message*. (A low battery in  
a portable wireless keypad is detected as soon as one of its keys is  
pressed, and displayed as 00.). Battery-operated smoke detectors with  
a low battery also emit a single "chirp" sound approximately once  
every 20–30 seconds.  
Replacing  
Batteries in  
Wireless Sensors  
Wireless sensors  
may not have  
been used in your  
security system  
Alkaline batteries provide a minimum of 1 year of operation, and in  
most units and applications, provide 2–4 years of service. 3-volt lithium  
batteries provide up to 4 or more years of operation. Actual battery life  
will depend on the environment in which the sensor is used, the  
number of signals that the transmitter in the sensor has had to send,  
and the specific type of sensor. Factors such as humidity, high or low  
temperatures or large swings in temperature, may all lead to the  
reduction of actual battery life in an installation.  
IMPORTANT:  
Use only batteries  
recommended by  
your installer as  
replacement.  
* The low battery message comes on as a warning that battery replacement  
in indicated sensor(s) is due within 30 days. In the meantime, a sensor  
causing a low battery indication is still fully operational.  
Treat the components of your security system as you would any other  
electrical equipment. Do not slam sensor-protected doors or windows.  
Keep dust from accumulating on the keypad and all protective  
sensors, particularly on motion sensors and smoke detectors.  
The keypad and sensors should be cleaned carefully with a dry soft  
cloth. Do n ot sp r a y w a ter or a n y oth er flu id on t h e u n its.  
Routine Care  
– 42 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Fire Alarm System (If Installed)  
THIS SECTION AP P LIES ONLY TO RESIDENTIAL SYSTEMS  
Your fire alarm system (if installed) is on 24 hours a day, for  
continuous protection. In the event of an emergency, the strategically  
located smoke and heat detectors will sound their alarms and  
automatically send signals to your system, triggering a loud,  
interrupted pulsed sound* from all keypads and any external  
sounders. A FIRE message will appear at your keypad and remain on  
until you silence the alarm (see below for silencing fire alarms).  
General  
* Temporal pulse sounding is produced for Fire alarms, as follows:  
3 pulses–pause–3 pulses–pause–3 pulses–pause. . . , repeated.  
TYP ICAL F IRE EMERGE NCY DISP LAYS  
AC  
F I R E 0 1  
M A S T E R  
01  
ALARM  
FIRE  
B E D R O O M  
ALP HA DISP LAY KE YP AD  
F IXED-WOR D KEYP AD  
1. You can silence the alarm at any time by pressing the OF F key (the  
security code is not needed to silence fire alarms). To clear the  
display, enter your code and press the OF F key again (to clear  
Memory of Alarm).  
Silencing  
Fire Alarms and  
Clearing Memory  
of Alarm  
2. If the keypad's FIRE display does not clear after the second OFF  
sequence, smoke detectors may still be responding to smoke or heat  
producing objects in their vicinity. Investigate, and should this be  
the case, eliminate the source of heat or smoke.  
3. If this does not remedy the problem, there may still be smoke in the  
detector. Clear it by fanning the detector for about 30 seconds.  
When the problem has been corrected, clear the display by  
entering your code and pressing the OF F key.  
Depending on the type of smoke detectors in your system, it may be  
necessary to "reset" the smoke detectors after a fire alarm has been  
turned off. Check with your installer. This "reset" is accomplished at a  
keypad, as follows:  
Smoke Detector  
Reset  
Enter Security Code*, then press the [1] key (* except arm only” user).  
NOTE: During smoke detector reset, FAULT xx” appears (about six  
seconds) and should disappear if the detector is clear.  
– 43 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Fire Alarm System (Continued)  
THIS SECTION AP P LIES ONLY TO RESIDENTIAL SYSTEMS  
1. Should you become aware of a fire emergency before your smoke or  
heat detectors sense the problem, go to your nearest keypad and  
manually initiate an alarm by pressing the panic key assigned for  
FIRE emergency for 2 seconds. If a key pair has been assigned for  
fire, press both keys at the same time. See the Using the Panic Keys  
section below for further details.  
Manually  
Initiating  
a Fire Alarm  
2. Evacuate all occupants from the premises.  
3. If flames and/or smoke are present, leave the premises and notify  
your local Fire Department immediately.  
4. If no flames or smoke are apparent, investigate the cause of the  
alarm. The zone number(s) of the zone(s) in an alarm condition will  
be displayed at the keypad.  
A key or key pair may have been assigned for manually initiating a  
FIRE alarm. See the Panic Keys section for key assignments.  
For convenience, indicate the key or key pair assigned for fire below.  
I n d i v i d u a l K e y s  
Using the Panic  
Key(s) Assigned  
for FIRE  
Emergency  
A
B
C
Press the individual key assigned for fire for 2 seconds.  
OR Key P a ir s  
1
3
O F F  
and R E A D Y (z on e 9 5 )  
Press the key pair  
assigned for fire at  
the same time.  
R E A D Y and  
#
#
(z on e 9 9 )  
(z on e 9 6 )  
S T A Y  
and  
DISP LAYS FOLLOWING MANUAL INITIATION OF A F IRE ALAR M  
AC  
F I R E 9 5  
95  
ALARM  
FIRE  
ALP HA DISP LAY KE YP AD  
F IXED-WORD KEYP AD  
If installed, carbon monoxide detectors provide continuous protection.  
If a high level of carbon monoxide is detected, an interrupted pulsed  
alarm sound occurs at the keypads and the detector(s). Immediately  
move to a spot where fresh air is available, preferably outdoors. From  
a safe area, call your security service provider for further instructions.  
To silence the keypad sounding, press the OF F key. To silence the  
detector, see its instructions.  
Carbon  
Monoxide  
Alarms  
– 44 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Fire Alarm System (Continued)  
THIS SECTION AP P LIES ONLY TO RESIDENTIAL SYSTEMS  
National Fire Protection Association  
Recommendations on Smoke Detectors  
With regard to the number and placement of smoke/heat detectors, we  
subscribe to the recommendations contained in the National Fire Protection  
Association's National Fire Alarm Code (NFPA 72) noted below.  
Early warning fire detection is best achieved by the installation of fire  
detection equipment in all rooms and areas of the household as follows: A  
smoke detector installed outside of each separate sleeping area, in the  
immediate vicinity of the bedrooms and on each additional story of the  
family living unit, including basements and excluding crawl spaces and  
unfinished attics.  
In addition, the NFPA recommends that you install heat or smoke detectors  
in the living room, dining room, bedroom(s), kitchen, hallway(s), attic,  
furnace room, utility and storage rooms, basements and attached garages.  
KITCHEN  
KITCHEN  
LIVING ROOM  
BDRM  
DINING  
BEDROOM  
BEDROOM  
TV ROOM  
DINING  
BDRM  
BEDROOM  
BEDROOM  
LIVING ROOM  
Smoke Detectors for Minimum Protection  
Smoke Detectors for Additional Protection  
Heat-Activated Detectors  
BEDROOM  
TO  
BR  
BEDROOM  
BEDROOM  
KTCHN  
GARAGE  
CLOSED  
DOOR  
LVNG RM  
.
BASEMENT  
floor_plan-001-V1  
– 45 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Fire Alarm System (Continued)  
THIS SECTION AP P LIES ONLY TO RESIDENTIAL SYSTEMS  
Emergency Evacuation  
Establish and regularly practice a plan of escape in the  
event of fire. The following steps are recommended by  
the National Fire Protection Association:  
OOM  
CLOSET  
BEDR  
1. Position your detector or your interior and/or  
exterior sounders so that they can be heard by all  
H
OOM  
OOM  
BEDR  
occupants.  
T
BA  
BEDR  
2. Determine two means of escape from each room.  
One path of escape should lead to the door that  
permits normal exit from the building. The other  
may be a window, should your path be impassable.  
Station an escape ladder at such windows if there  
is a long drop to the ground.  
2ND FLOOR  
OOM  
KITCHEN  
BEDR  
BACK DOOR  
H
OOM  
T
3. Sketch a floor plan of the building. Show windows,  
doors, stairs and rooftops that can be used to  
escape. Indicate escape routes for each room. Keep  
these routes free from obstruction and post copies  
of the escape routes in every room.  
BA  
BEDR  
1ST FLOOR  
4. Assure that all bedroom doors are shut while you  
are asleep. This will prevent deadly smoke from  
entering while you escape.  
5. Try the door. If the door is hot, check your  
alternate escape route. If the door is cool, open it  
cautiously. Be prepared to slam the door if smoke  
or heat rushes in.  
BACK  
6. When smoke is present, crawl on the ground. Do  
not walk upright, since smoke rises and may  
overcome you. Clearer air is near the floor.  
7. Escape quickly; don't panic.  
FRONT  
8. Establish a common meeting place outdoors, away  
from your house, where everyone can meet and  
then take steps to contact the authorities and  
account for those missing. Choose someone to  
assure that nobody returns to the house — many  
die going back  
– 46 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Quick Guide to Basic System Functions  
F UNCTION  
Ch eck Zon es  
P ROCEDURE  
COMMENTS  
Press READY key.  
View faulted zones when system not  
ready.  
Enter code. Press arming key desired:  
Arms system in mode selected.  
Ar m System  
(AWAY, STAY, NIGHT-STAY,  
MAXIMUM, INSTANT)  
Press #. Press arming key desired:  
(AWAY, STAY, MAXIMUM, INSTANT)  
Arms system in mode selected, quickly  
and without use of a code.  
Qu ick Ar m  
(if programmed)  
Enter code. Press BYPASS [6] key.  
Enter zone number(s) to be bypassed  
(use 2-digit entries).  
Bypassed zones are unprotected and  
will not cause an alarm if violated.  
Byp a ss Zon e(s)  
Enter code. Press BYPASS [6] key + [#].  
Bypasses all faulted zones  
automatically.  
Qu ick Byp a ss  
(if programmed)  
Silen ce Sou n d er s  
Bu r gla r y:  
Enter code. Press OFF [1] key.  
Also disarms system. Memory of alarm  
remains until cleared.  
F ir e:  
Press OFF [1] key.  
Press any key.  
Memory of Alarm remains until cleared.  
Determine cause.  
"Ch eck ":  
Enter code. Press OFF [1] key. (OFF  
need not be pressed if entry delay or an  
alarm is active)  
Also silences sounders. Memory of  
alarm remains until cleared.  
Disa r m System  
Clea r Ala r m  
Mem or y  
After disarming, enter code again.  
Press OFF [1] key again.  
Keypad beeps rapidly on entry if alarm  
has occurred while absent. Alarm  
display will remain upon disarming  
until cleared.  
Du r ess (if active  
and connected to  
Central Station)  
Arm or disarm "normally", but  
use your 4-digit Duress code to do so.  
Performs desired action and sends  
silent alarm to Central Station.  
Press key [A], [B], or [C] for at least 2  
See the Panic Keys section for  
P a n ic Ala r m s  
(as programmed)  
seconds or press and hold designated key emergency functions programmed for  
your system. Note: Keys A”, “B, and  
C” may have been programmed for  
other functions.  
pairs: [1]+[], or [] + [#], or [3] + [#].  
To turn ON or OFF: Enter code. Press  
CHIME key.  
The keypad will sound if doors or  
windows are violated while system is  
disarmed and chime mode is ON.  
Ch im e Mod e  
Test Mod e  
To turn ON: Enter code. Press TEST key, Tests alarm sounder and allows sensors  
then [0].  
to be tested.  
To turn OFF: Enter code. Press OFF key.  
P h on e Access  
if applicable  
Consult Phone Access User's Guide that  
accompanies the Phone Module.  
Permits system access remotely, via  
Touch-tone phone.  
47 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Summary of Audible/Visual Notifications  
Fixed-Word Display Keypads  
SOUND  
CAUSE  
DISP LAY  
LOUD,  
INTERRUPTED  
Keypad & Ext.  
FIRE ALARM  
F IRE is displayed; zone number of zone in  
alarm is displayed. If a fire alarm is manually  
activated, zone number 95 will be displayed.  
*
LOUD,  
CONTINUOUS  
Keypad & Ext.  
BURGLARY/AUDIBLE  
EMERGENCY ALARM  
ALARM is displayed. Zone number of zone in  
alarm is also displayed.  
*
ONE SHORT BEEP a. SYSTEM DISARM  
a. READY indicator light comes on.  
(not repeated)  
Keypad only  
b. SYSTEM ARMING ATTEMPT  
WITH AN OPEN ZONE.  
b. Number of the open protection zone displayed.  
c. Zone numbers of the bypassed protection  
zones are displayed (one beep is heard for  
each zone displayed). Subsequently, BYP ASS  
is displayed.  
c. BYPASS VERIFY  
ONE SHORT BEEP a. SYSTEM IS IN TEST MODE  
a. Opened zone numbers will appear.  
(about every 30  
secs)  
b. LOW BATTERY AT A  
TRANSMITTER  
b. BAT displayed with zone number of  
transmitter.  
Keypad only  
c. SYSTEM WILL AUTOARM  
WITHIN 10 MINUTES  
c. No special display.  
TWO SHORT BEEPS ARM AWAY or MAXIMUM  
Keypad only  
AWAY is displayed. Red ARMED indicator is lit.  
THREE SHORT  
BEEPS  
a. ARM STAY, NIGHT-STAY, OR  
INSTANT  
a. STAY or INSTANT is displayed. Red  
ARMED indicator is lit.  
Keypad only  
b. CHIME displayed; zone number of open  
protection zone will be displayed if the []  
key is pressed.  
b. ZONE OPENED WITH  
SYSTEM IN CHIME MODE.  
RAPID BEEPING  
Keypad only  
a. TROUBLE  
a. CHECK displayed. Zone number of troubled  
protection zone is displayed.  
b. MEMORY OF ALARM  
b. F IRE or ALARM is displayed; zone number  
of zone in alarm is displayed  
c. BAT displayed with no zone ID number.  
d. CHECK 70 is displayed.  
e. No special display.  
c. SYSTEM LOW BATTERY  
d. EXT. SOUNDER WIRING FAIL  
e. LAST 10 SEC of EXIT DELAY  
SLOW BEEPING  
Keypad only  
a. AWAY is displayed.  
a. EXIT DELAY WARNING  
b. ENTRY DELAY WARNING  
b. Exceeding the entry delay time without  
disarming causes alarm.  
*
If a bell is used as external sounder, fire alarm is pulsed ring; burglary/audible emergency is steady ring.  
48 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Summary of Audible/Visual Notifications  
Alpha Display Keypads  
SOUND  
CAUSE  
DISP LAY  
LOUD,  
INTERRUPTED*  
Keypad & Ext.  
FIRE ALARM.  
F IRE is displayed; descriptor of zone in alarm is  
displayed. If a fire alarm is manually activated, zone  
number 95 will be displayed.  
LOUD,  
CONTINUOUS*  
Keypad & Ext.  
BURGLARY/AUDIBLE  
EMERGENCY ALARM.  
ALARM is displayed. If programmed, descriptor of  
zone in alarm is also displayed  
ONE SHORT BEEP a. SYSTEM DISARM.  
(not repeated)  
a. DISARMED/READY TO ARM is displayed.  
b. Number and descriptor of open protection zone is  
displayed.  
b. SYSTEM ARMING ATTEMPT  
Keypad only  
WITH AN OPEN ZONE.  
c. Numbers and descriptors of the bypassed zones  
are displayed (One beep is heard for each  
c. BYPASS VERIFY.  
zone displayed). Subsequently, the following is  
displayed: DISARMED BYP ASS /Rea d y to Ar m .  
ONE SHORT BEEP a. SYSTEM IS IN TEST MODE. a. Opened Zone identifications will appear.  
(about every 30  
secs)  
Keypad only  
b, LOW BATTERY AT A  
TRANSMITTER.  
b. LO BAT displayed with description of transmitter.  
c. No special display.  
c. SYSTEM WILL AUTOARM  
WITHIN 10 MINUTES  
TWO SHORT BEEPS ARM AWAY or MAXIMUM.  
Keypad only  
AR ME D AWAY or MAXIMUM displayed. Red  
ARMED indicator lit.  
THREE SHORT  
BEEPS  
a. ARM STAY, NIGHT-STAY,  
OR INSTANT.  
a. ARMED STAY or ARMED INSTANT displayed.  
Red ARMED indicator lit.  
Keypad only  
b. CHIME displayed, descriptor of open protection  
zone will be displayed if the [] key is pressed.  
b. ZONE OPENED WHILE  
SYSTEM IS DISARMED.  
a. CHECK displayed. Descriptor of troubled  
protection zone is displayed.  
b. F IRE or ALARM is displayed; descriptor of zone  
in alarm is displayed.  
c. SYSTEM LO BAT displayed.  
d. BELL F AILURE is displayed.  
e. No special display.  
RAPID BEEPING  
Keypad only  
a. TROUBLE.  
b. MEMORY OF ALARM.  
c. SYSTEM LOW BATTERY.  
d. EXT. SOUNDER WIRE FAIL  
e. LAST 10 SEC of EXIT DELAY.  
SLOW BEEPING  
Keypad only  
a. EXIT DELAY WARNING  
(if programmed).  
a. ARME D AWAY OR MAXIMUM is displayed  
along with You Ma y Exit Now .  
b. DISARM SYSTEM OR ALARM WILL OCCUR  
is displayed. Exceed in g th e d ela y tim e w ith ou t  
d isa r m in g ca u ses a n a la r m .  
b. ENTRY DELAY WARNING.  
* If a bell is used as external sounder, fire alarm is pulsed ring; burglary/audible emergency is steady  
ring.  
49 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Regulatory Statements and Warnings  
“F E DER AL COMMUNICATIONS COMMISSION (F CC) P a r t 15 STATEMENT”  
This equipment has been tested to FCC requirements and has been found acceptable for use. The FCC requires the  
following statement for your information:  
This equipment generates and uses radio frequency energy and if not installed and used properly, that is, in strict  
accordance with the manufacturers instructions, may cause interference to radio and television reception. It has  
been type tested and found to comply with the limits for a Class B computing device in accordance with the  
specifications in Part 15 of FCC Rules, which are designed to provide reasonable protection against such  
interference in a residential installation. However, there is no guarantee that interference will not occur in a  
particular installation. If this equipment does cause interference to radio or television reception, which can be  
determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or  
more of the following measures:  
If using an indoor antenna, have a quality outdoor antenna installed.  
Reorient the receiving antenna until interference is reduced or eliminated.  
Move the receiver away from the control/communicator.  
Move the antenna leads away from any wire runs to the control/communicator.  
Plug the control/communicator into a different outlet so that it and the receiver are on different branch circuits.  
If necessary, the user should consult the dealer or an experienced radio/television technician for additional  
suggestions.  
The user or installer may find the following booklet prepared by the Federal Communications Commission helpful:  
Interference Handbook”  
This booklet is available from the U.S. Government Printing Office, Washington, DC 20402.  
The user shall not make any changes or modifications to the equipment unless authorized by the Installation  
Instructions or Users Manual. Unauthorized changes or modifications could void the users authority to operate the  
equipment.  
50 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Regulatory Statements (Continued)  
TELEP HONE/MODEM INTERF ACE  
F CC P a r t 68  
This equipment complies with Part 68 of the FCC rules. On the front cover of this equipment is a label that contains the FCC  
registration number and Ringer Equivalence Number (REN). You must provide this information to the telephone company when  
requested.  
This equipment uses the following USOC jack: RJ 31X  
This equipment may not be used on telephone-company-provided coin service. Connection to party lines is subject to state tariffs.  
This equipment is hearing-aid compatible.  
In d u str y Ca n a d a  
NOTICE: The Industry Canada Label identifies certified equipment. This certification means that the equipment meets  
telecommunications network protective, operational and safety requirements as prescribed in the appropriate Terminal  
Equipment Technical Requirements document(s). The Department does not guarantee the equipment will operate to the users  
satisfaction.  
Before installing this equipment, users should ensure that it is permissible to be connected to the facilities of the local  
telecommunications company. The equipment must also be installed using an acceptable method of connection. The customer  
should be aware that compliance with the above conditions may not prevent degradation of service in some situations.  
Repairs to certified equipment should be coordinated by a representative designated by the supplier. Any repairs or alterations  
made by the user to this equipment, or equipment malfunctions, may give the telecommunications company to request the user to  
disconnect the equipment.  
Users should ensure for their own protection that the electrical ground connections of the power utility, telephone lines and  
internal metallic water pipe system, if present, are connected together, This precaution may be particularly important in rural  
areas.  
Ca u t ion : Users should not attempt to make such connections themselves but should contact appropriate electric inspection  
authority, or electrician, as appropriate.  
Rin ger Eq u iva len ce Nu m b er Notice:  
The R in ger Eq u iva len ce Nu m b er (REN) assigned to each terminal device provides an indication of the maximum number of  
terminals allowed to be connected to a telephone interface. The termination on an interface may consist of any combination of  
devices subject only to the requirement that the sum of the Ringer Equivalence Numbers of all the devices does not exceed 5.  
In d u str ie Ca n a d a  
AVIS: létiquette dIndustrie Canada identifie le matériel homologué. Cette étiquette certifie que le matériel est conforme aux  
normes de protection, dexploitation et de sécurité des réseaux de télécommunications, comme le prescrivent les documents  
concernant les exigences techniques relatives au matériel terminal. Le Ministère nassure toutefois pas que le matériel  
fonctionnera à la satisfaction de lutilisateur.  
Avant dinstaller ce matériel, lutilisateur doit sassurer quil est permis de le raccorder aux installations de lenterprise locale de  
télécommunication. Le matériel doit également être installé en suivant une méthode acceptée da raccordement. Labonné ne doit  
pas oublier quil est possible que la conformité aux conditions énoncées ci-dessus nempêche pas la dégradation du service dans  
certaines situations.  
Les réparations de matériel nomologué doivent être coordonnées par un représentant désigné par le fournisseur. Lentreprise de  
télécommunications peut demander à lutilisateur da débrancher un appareil à la suite de réparations ou de modifications  
effectuées par lutilisateur ou à cause de mauvais fonctionnement.  
Pour sa propre protection, lutilisateur doit sassurer que tous les fils de mise à la terre de la source denergie électrique, de lignes  
téléphoniques et des canalisations deau métalliques, sil y en a, sont raccordés ensemble. Cette précaution est particulièrement  
importante dans les régions rurales.  
Aver t issem en t : Lutilisateur ne doit pas tenter de faire ces raccordements lui-même; il doit avoir racours à un service  
dinspection des installations électriques, ou à un électricien, selon le cas.  
AVIS : Lin d ice d éq u iva len ce d e la son n er ie (IES) assigné à chaque dispositif terminal indique le nombre maximal de  
terminaux qui peuvent être raccordés à une interface. La terminaison dune interface téléphonique peut consister en une  
combinaison de quelques dispositifs, à la seule condition que la somme dindices déquivalence de la sonnerie de tous les dispositifs  
nexcède pas 5.  
51 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Charts of Your System’s Features  
Features marked with a dagger apply to the FA168CPS only.  
Features  
Comments  
Exit Delay  
Part. 1:  
Part. 1:  
Part. 1:  
Zones:  
yes  
Part. 2 :  
Entry Delay 1  
Entry Delay 2  
Part. 2 :  
Part. 2 :  
Night-Stay Zones  
Quick Arm  
no  
no  
no  
Quick Bypass  
yes  
Automatic Paging  
Keyswitch Arming  
(circle type of LED lighting)  
yes  
users:  
flash  
flash  
Arm AWAY: steady  
Arm STAY: steady  
F u n ct ion Keys  
A
B
C
D
Com m en ts  
Single-Button Arming  
Step Arming  
Paging (see Paging chart)  
Time/Date Display  
Macro Key 1  
Macro Key 2  
Macro Key 3  
Macro Key 4  
††  
Emergency Key : Personal  
††  
Emergency Key : Silent Alarm  
††  
Emergency Key : Audible Alarm  
††  
Emergency Key : Fire  
Device Activation  
Device:  
†† Emergency Keys:  
A = [1] / []  
B = [] / [#]  
C = [3] / [#]  
52 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Charts of Your System’s Features  
User Set u p  
The following chart will help keep track of system users. Copies should be  
distributed to the partition 1 and partition 2 (if applicable) masters for their records.  
To program a user attribute:  
Enter system/partition master code + [8] + user no. + #” command listed in column heading…  
Users Part(s).†  
User  
No.  
User  
Name  
Security  
Code  
enter new code  
Auth.  
Level  
Access  
Group  
RF Zone  
Number  
Pager  
on/off  
(system master only)  
[#] [3] + part(s) + [#]  
[#] [1] + level [#] [2] + group [#] [4] + zone no. [#] [5] + 0/1  
01  
02  
03  
04  
05  
06  
07  
08  
09  
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
21  
22  
23  
24  
25  
26  
27  
28  
29  
30  
31  
32  
installer  
system master  
partition 1 master  
(all)  
(all)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
installer  
master  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(4)  
(0)  
(0)  
(0)  
(0)  
(0)  
(0)  
(0)  
(0)  
(0)  
(0)  
(0)  
(0)  
(0)  
(0)  
(0)  
(0)  
(0)  
(0)  
(0)  
(0)  
(0)  
(0)  
(0)  
(0)  
(0)  
(0)  
(0)  
(0)  
(0)  
Partitions apply to the FA168CPS only.  
53 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Charts of Your System’s Features  
User Set u p (con t in u ed )  
Enter system/partition master code + [8] + user no. + #” command listed in column heading…  
User  
No.†  
User  
Name  
Users Part(s).  
Security  
Code  
enter new code  
Auth.  
Level  
Access  
Group  
RF Zone  
Number  
Pager  
on/off  
(system master only)  
[#] [3] + part(s) + [#]  
[#] [1] + level [#] [2] + group [#] [4] + zone no. [#] [5] + 0/1  
33  
34  
35  
36  
37  
38  
39  
40  
41  
42  
43  
44  
45  
46  
47  
48  
49  
partition 2 master  
(2)  
(2)  
(2)  
(2)  
(2)  
(2)  
(2)  
(2)  
(2)  
(2)  
(2)  
(2)  
(2)  
(2)  
(2)  
(2)  
(2)  
(4)  
(0)  
(0)  
(0)  
(0)  
(0)  
(0)  
(0)  
(0)  
(0)  
(0)  
(0)  
(0)  
(0)  
(0)  
(0)  
(0)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
(1)  
Authority Levels: 0 = standard user  
1 = arm only  
Partitions:0 = clears partition 1 and partition 2 assignments  
1 = partition 1 and common  
2 = partition 2 and common  
3 = common partition only  
2 = guest  
3 = duress  
4 = partition master  
Paging: 0 = no paging  
1 = allow paging  
Users 34-49 apply to FA168CPS only; user 33 is partition 2 master for FA168CPS, and the last user for FA148CP.  
54 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Charts of Your System’s Features  
P a gin g Set u p  
Automatically Reports Upon…  
open/close alarm/trouble zone list  
p1 p2  
Sched. Func. Key  
Pager Phone Number\  
Pager Prefix Characters  
p1  
p2  
p1  
p2  
1
2
3
4
Pagers 3 and 4 apply to FA168CPS.  
Sch ed u les: master code + [#] + [6] [4]. ( FA168CPS can use schedules 01-16; FA148CP can only use schedules 01-04.)  
No.  
Event  
Device No.  
Group No. Partition††  
for 02events: for 04-06events: Time/  
Start  
Stop  
Time/  
Day  
Repeat Random  
(see list below) for 01events:  
(1-4)  
(yes/no)  
(see device list below) enter 1-8  
enter 1, 2, or 3  
Day  
01  
02  
03  
04  
05†  
06†  
07†  
08†  
09†  
10†  
11†  
12†  
13†  
14†  
15†  
16†  
Events:  
00 = clear event  
01 = device on/off  
02 = user access  
03 = latch key report  
04 = forced STAY arm  
05 = forced AWAY arm  
06 = auto disarm  
07 = display reminder”  
†† Partitions apply to the FA168CPS only.  
Repeat Options: 0 = none; 1 = repeat weekly; 2 = repeat every other week; 3 = repeat every third week; 4 = repeat every fourth week  
55 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
List of Ou tp u t Devices  
(† FA168CPS can use devices 01-16; FA148CP can only use devices 01-08; both can use trigger devices 17/18.)  
Device†  
01  
02  
03  
04  
05  
06  
07  
08  
09  
10  
11  
12  
13  
14  
15  
16  
17  
18  
Description  
Schedule No.  
Function Key  
56 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
– Notes –  
57 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
– Notes –  
58 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
– Notes –  
59 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
– Notes –  
60 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OWNERS INSURANCE P REMIUM CREDIT REQUEST  
This form should be completed and forwarded to your homeowners insurance carrier for possible  
premium credit.  
A. GENER AL INF OR MATION:  
Insureds Name and Address:  
Insurance Company:  
Policy No.:  
F A168CP S / F A148CP  
Other ______________________________________________________  
(circle the appropriate model number)  
Type of Alarm:  
Installed by:  
Burglary  
Fire  
Both  
Serviced by:  
Name  
Name  
Address  
Address  
B. NOTIF IES (In ser t B = Bu r gla r y, F = F ir e)  
Local Sounding Device  
Police Dept.  
Fire Dept.  
Central Station  
Name:  
Address:  
Phone:  
C. P OWERED BY: A.C. With Rechargeable Power Supply  
D. TESTING: Quarterly Monthly Weekly  
Other  
continued on other side  
61 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OWNERS INSURANCE P REMIUM CREDIT REQUEST  
(con t .)  
E. SMOKE DETECTOR LOCATIONS  
Furnace Room  
Basement  
Kitchen  
Bedrooms  
Attic  
Hall  
Living Room  
Dining Room  
F . BURGLARY DETE CTING DEVICE LOCATIONS:  
Front Door  
Basement Door  
All windows  
Rear Door  
All Exterior Doors  
1st Floor Windows  
Interior locations  
All Accessible Openings, Including Skylights, Air Conditioners and Vents  
G. ADDITIONAL P ERTINENT INF ORMATION:  
Signature:  
Date:  
62 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
LIMITATIONS OF THIS SYSTEM  
WARNING! THE LIMITATIONS OF THIS ALARM SYSTEM  
While this system is an advanced design security system, it does not offer guaranteed protection against burglary or other  
emergency. Any alarm system, whether commercial or residential, is subject to compromise or failure to warn for  
variety of reasons. For example:  
a
Intruders may gain access through unprotected openings or have the technical sophistication to bypass an alarm  
sensor or disconnect an alarm warning device.  
Intrusion detectors (e.g. passive infrared detectors), smoke detectors, and many other sensing devices will not work  
without power. Battery operated devices will not work without batteries, with dead batteries, or if the batteries are  
not put in properly. Devices powered solely by AC will not work if their AC power supply is cut off for any reason,  
however briefly.  
Signals sent by wireless transmitters may be blocked or reflected by metal before they reach the alarm receiver. Even  
if the signal path has been recently checked during a weekly test, blockage can occur if a metal object is moved into  
the path.  
A user may not be able to reach a panic or emergency button quickly enough.  
While smoke detectors have played a key role in reducing residential fire deaths in the United States, they may not  
activate or provide early warning for a variety of reasons in as many as 35% of all fires, according to data published  
by the Federal Emergency Management Agency. Some of the reasons smoke detectors used in conjunction with this  
System may not work are as follows. Smoke detectors may have been improperly installed and positioned. Smoke  
detectors may not sense fires that start where smoke cannot reach the detectors, such as in chimneys, in walls, or  
roofs, or on the other side of closed doors. Smoke detectors also may not sense a fire on another level of a residence or  
building. A second floor detector, for example, may not sense a first floor or basement fire. Moreover, smoke detectors  
have sensing limitations. No smoke detector can sense every kind of fire every time. In general, detectors may not  
always warn about fires caused by carelessness and safety hazards like smoking in bed, violent explosions, escaping  
gas, improper storage of flammable materials, overloaded electrical circuits, children playing with matches, or arson.  
Depending upon the nature of the fire and/or the locations of the smoke detectors, the detector, even if it operates as  
anticipated, may not provide sufficient warning to allow all occupants to escape in time to prevent injury or death.  
Passive Infrared Motion Detectors can only detect intrusion within the designed ranges as diagrammed in their  
installation manual. Passive Infrared Detectors do not provide volumetric area protection. They do create multiple  
beams of protection, and intrusion can only be detected in unobstructed areas covered by those beams. They cannot  
detect motion or intrusion that takes place behind walls, ceilings, floors, closed doors, glass partitions, glass doors, or  
windows.  
Mechanical tampering, masking, painting or spraying of any material on the mirrors, windows or any part of the  
optical system can reduce their detection ability. Passive Infrared Detectors sense changes in temperature; however,  
as the ambient temperature of protected area approaches the temperature range of 90° to 105°F, the detection  
performance can decrease.  
Alarm warning devices such as sirens, bells or horns may not alert people or wake up sleepers if they are located on  
the other side of closed or partly open doors. If warning devices sound on a different level of the residence from the  
bedrooms, then they are less likely to waken or alert people inside the bedrooms. Even persons who are awake may  
not hear the warning if the alarm is muffled from a stereo, radio, air conditioner or other appliance, or by passing  
traffic. Finally, alarm warning devices, however loud, may not warn hearing-impaired people or waken deep sleepers.  
Telephone lines needed to transmit alarm signals from a premises to a central monitoring station may be out of  
service or temporarily out of service. Telephone lines are also subject to compromise by sophisticated intruders.  
Even if the system responds to the emergency as intended, however, occupants may have insufficient time to protect  
themselves from the emergency situation. In the case of a monitored alarm system, authorities may not respond  
appropriately.  
This equipment, like other electrical devices, is subject to component failure. Even though this equipment is designed  
to last as long as 10 years, the electronic components could fail at any time.  
The most common cause of an alarm system not functioning when an intrusion or fire occurs is inadequate maintenance.  
This alarm system should be tested weekly to make sure all sensors and transmitters are working properly.  
Installing an alarm system may make one eligible for lower insurance rates, but an alarm system is not a substitute for  
insurance. Homeowners, property owners and renters should continue to act prudently in protecting themselves and  
continue to insure their lives and property.  
We continue to develop new and improved protection devices. Users of alarm systems owe it to themselves and their loved  
ones to learn about these developments.  
63 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ONE YEAR LIMITED WARRANTY  
Honeywell International Inc., acting through its First Alert Professional business ("Seller"), 2 Corporate  
Center Drive, New York 11747, warrants its First Alert Professional security equipment (the "product") to be  
free from defects in materials and workmanship for one year from date of original purchase, under normal  
use and service. Seller's obligation is limited to repairing or replacing, at its option, free of charge for parts,  
labor, or transportation, any product proven to be defective in materials or workmanship under normal use  
and service. Seller shall have no obligation under this warranty or otherwise if the product is altered or  
improperly repaired or serviced by anyone other than the Seller. In case of defect, contact the security  
professional who installed and maintains your security equipment or the Seller for product repair.  
This one year Limited Warranty is in lieu of all other express warranties, obligations or liabilities. THERE  
ARE NO EXPRESS WARRANTIES, WHICH EXTEND BEYOND THE FACE HEREOF. ANY IMPLIED  
WARRANTIES, OBLIGATIONS OR LIABILITIES MADE BY SELLER IN CONNECTION WITH THIS  
PRODUCT, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY, OR FITNESS FOR  
A PARTICULAR PURPOSE OR OTHERWISE, ARE LIMITED IN DURATION TO A PERIOD OF ONE  
YEAR FROM THE DATE OF ORIGINAL PURCHASE. ANY ACTION FOR BREACH OF ANY  
WARRANTY, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF  
MERCHANTABILITY, MUST BE BROUGHT WITHIN 12 MONTHS FROM DATE OF ORIGINAL  
PURCHASE. IN NO CASE SHALL SELLER BE LIABLE TO ANYONE FOR ANY CONSEQUENTIAL  
OR INCIDENTAL DAMAGES FOR BREACH OF THIS OR ANY OTHER WARRANTY, EXPRESS OR  
IMPLIED, OR UPON ANY OTHER BASIS OF LIABILITY WHATSOEVER, EVEN IF THE LOSS OR  
DAMAGE IS CAUSED BY THE SELLER'S OWN NEGLIGENCE OR FAULT. Some states do not allow  
limitation on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential  
damages, so the above limitation or exclusion may not apply to you.  
Seller does not represent that the product may not be compromised or circumvented; that the product will  
prevent any personal injury or property loss by burglary, robbery, fire or otherwise; or that the product will in  
all cases provide adequate warning or protection. Buyer understands that a properly installed and maintained  
alarm may only reduce the risk of a burglary, robbery, fire or other events occurring without providing an  
alarm, but it is not insurance or a guarantee that such will not occur or that there will be no personal injury or  
property loss as a result. CONSEQUENTLY, SELLER SHALL HAVE NO LIABILITY FOR ANY  
PERSONAL INJURY, PROPERTY DAMAGE OR OTHER LOSS BASED ON A CLAIM THE PRODUCT  
FAILED TO GIVE WARNING. HOWEVER, IF SELLER IS HELD LIABLE, WHETHER DIRECTLY OR  
INDIRECTLY, FOR ANY LOSS OR DAMAGE ARISING UNDER THIS LIMITED WARRANTY OR  
OTHERWISE, REGARDLESS OF CAUSE OR ORIGIN, SELLER'S MAXIMUM LIABILITY SHALL  
NOT IN ANY CASE EXCEED THE PURCHASE PRICE OF THE PRODUCT, WHICH SHALL BE THE  
COMPLETE AND EXCLUSIVE REMEDY AGAINST SELLER. This warranty gives you specific legal  
rights, and you may also have other rights which vary from state to state. No increase or alteration, written or  
verbal, to this warranty is authorized.  
2 Corporate Center Drive, Suite 100  
P.O. Box 9040, Melville, NY 11747  
Copyright © 2003 Honeywell International Inc.  
ÊK5309-5V5MŠ  
K5309-5V5 11/08 Rev. A  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Electro Voice Music Mixer electro voice power mixer series User Manual
Electro Voice Speaker System SE 42 User Manual
Everpure Water Dispenser EV9613 01 User Manual
Everpure Water System EV9330 42 User Manual
Extron electronic Stereo Amplifier DA SV EQ Series User Manual
Fluke Thermometer 2180A User Manual
Fostex CD Player CR200 User Manual
GE Monogram Beverage Dispenser ZDWG240 User Manual
Generac Portable Generator 5500EXL User Manual
Gianni Industries Door LHS 50 User Manual