GXRM10R
GE® Reverse Osmosis Filtration System
Dimensions and Installation Information (in inches)
Note: R.O. System can be installed up to 30 feet from point-of-use/faucet.
RO Product Water
Faucet Mounted
Through Sink
Note: Can be installed under counter (as shown), in basement, or other
convenient location. Before installing, see installation instructions packed
with product for complete details.
3/8 Drain Tubing
9-3/4
Replacement Membranes, Pre- and Post-Filters
Call SmartWater Services, toll-free, 800.952.5039 for convenient ordering.
Caution: Do not use with water that is microbiologically unsafe or of
unknown quality, without adequate disinfection before or after the system.
Systems certified for cyst reduction may be used on disinfected water
that may contain filterable cysts. This reverse osmosis unit contains
a replaceable membrane cartridge treatment component critical for
effective removal of Total Dissolved Solids. The water should be tested
periodically to verify that the system is performing satisfactorily.
minimum 4" from bottom of sink
to top of horizontal “T” connection
Disposer
Drain
Line
Hot Cold
Sink P-Trap
GE Reverse Osmosis Model GXRM10R Series are tested and certified to
AnSi/nSF Standard 58 for TDS and cyst reduction.
Reverse Osmosis System
15
See Performance Data Sheet for details.
Independently Tested
This product has been independently tested by nSF and WQA, two of the
most highly recognized testing institutions in the water treatment industry.
Product performance testing details by each test facility are specified on
the Performance Data Sheet (inside the product box).
15-1/2
Depth
5-1/2
11" Dia.
14
For answers to your Monogram,® GE Profile™ or
GE® appliance questions, visit our website at
ge.com or call GE Answer Center® service,
800.626.2000.
Listed by
Underwriters
Laboratories
Specification Revised 9/09
380109
Download from Www.Somanuals.com. All Manuals Search And Download.
|