ZVC48LSS
GE Monogram® 48" Custom Hood Insert
Custom Insert Liner
Dimensions and Specifications (in inches)
Outside Dimensions
The custom canopy must be sized to fit the insert sleeve.
Construct the canopy with an opening that is:
38-3/4"W x 13-3/16"D
The opening must be constructed of 3/4" thick material to
allow the sleeve locking clips to engage.
The Insert Sleeve
The Supplied Liner
A stainless steel liner is shipped with each hood insert. This
non-combustible liner protects the underside of the canopy.
Custom Liner
If you are not using the supplied liner, you may construct a
custom non-combustible liner. Use the supplied liner as a
template. The opening must be 38-3/4"W x 13-3/16"D.
3/4" thick material must surround the opening to allow the
sleeve locking clips to engage. The insert sleeve inside the
cabinet should be positioned 1/2" from the rear wall so that
the center of the 8" duct is 5-1/2" from the rear wall.
Remote Location for the Control
The control may be removed from the hood and installed
into a wall or countertop. A 30-ft length of wire is supplied to
accommodate most installations. A blanking plate covers the
opening when the controls are removed. The overall size of
the control is 4-1/4" wide and 2-1/4" deep.
3-11/16"
1-11/16"
For answers to your Monogram,® GE Profile™ or
GE® appliance questions, visit our website at
ge.com or call GE Answer Center® service,
800.626.2000.
We recommend that the cutout in granite or other hard
surfaces be made before the countertop is installed.
Specification Created 10/06