ZHU36RSM
GE Monogram® 36" Induction Cooktop
Dimensions and Installation Information (in inches)
A
B
16" Min
2" Min.
to Side Walls
Junction
Box
1-3/4"
Min.
C
D
2-1/2"
Min.
to Front
Edge
Dimensions:
B
B
36" Models
A
(depth at sides)
(depth at center)
C
D
ZHU36RSM
36-1/8"
20-15/32"
21"
33-7/8" 19-1/8"
3-1/4"
Electrical requirements
Product rating is 120/240V, 60Hz, 36" cooktops
require a 50-amp circuit. The cooktops must
be connected to a supply circuit of the proper
voltage and frequency and protected by a time-
delay fuse or circuit breaker.
4-5/8" at
Note: When the cooktop is installed over an oven, the baffle at
the front is not required.
Combination installations
All models require 12"
minimum clearance below the
cooktop bottom to combustible
materials.
Consideration must be given to electrical supply locations
when the cooktop is installed with other products in the same
cabinet. Always refer to each product's installation instructions
for clearances and electrical requirements.
• Install these cooktops with any exhaust hood of the same
or treater width; 300 CFM or greater air flow rating is
recommended.
The cooktop bottom has air
intake ports toward the front
that help cool the components.
Do not install a shelf or
partition beneath the cooktop
that is more than 18" deep.
• This 36" cooktop may be installed in combination with
a Monogram® 36" downdraft vent. See downdraft vents
for details.
• A Monogram single oven may be installed below these
cooktops.
For answers to your Monogram,® GE Profile™ or
GE® appliance questions, visit our website at
ge.com or call GE Answer Center® service,
800.626.2000.
The serial plate is located on the bottom of the cooktops.
Listed by
Underwriters
Laboratories
Specification Revised 11/07
130253