GE Air Conditioner agh08 User Manual

GE Appliances  
Room  
Air  
Conditioners  
Owners Manual &  
Installation Instructions  
AGH08  
AGP08  
AGV08  
Pub. No. 49-7368-2 CG 12-97  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IMPORTANT SAFETY INFORMATION.  
READ ALL INSTRUCTIONS BEFORE USING.  
SafeyInstr  
WARNING!  
For your safety, the information in this manual must be followed to minimize the risk of fire, electric shock  
or personal injury.  
uctions  
SAFETY PRECAUTIONS  
This air conditioner must be properly  
installed in accordance with the Installation  
Instructions before it is used.  
Turn the mode control to OFF and unplug  
your air conditioner before making any  
repairs.  
OpeaigInstr  
Repair or replace immediately all electric  
service cords that have become frayed or  
otherwise damaged.  
NOTE: We strongly recommend that any  
servicing be performed by a qualified  
individual.  
uctions  
USE OF EXTENSION CORDS  
The use of an extension cord is not  
recommended. However, if an extension cord  
is required to reach the nearest wall receptacle,  
use only a UL-listed, 3-wire, grounded, 14  
gauge, 15A, 125V appliance extension cord.  
laioInstr  
USE OF ADAPTER PLUGS  
Because most 2-prong outlets are not  
grounded, we strongly advise against using an  
adapter plug. However, a temporary  
For Proper Grounding:  
Screw the adapter to the outlet, using the  
uctions  
outlet cover screw.  
connection may be made where local codes  
permit and if the 2-prong wall outlet is properly Ground the outlet through the house wiring.  
grounded. UL-listed adapters are available at  
When disconnecting the power cord from the  
most hardware stores.  
adapter, hold the adapter close to the outlet  
while pulling the plug out. If this is not done,  
T
r
When you plug the adapter in, make sure the  
ubleshotingT  
larger prong goes into the larger slot to provide the grounding connector is likely to break with  
the proper polarity for the power cord.  
repeated use.  
If the grounding connector breaks, DO NOT USE  
the air conditioner until a proper ground has  
again been made.  
ips  
Read and follow this Safety Information carefully.  
SAVE THESE INSTRUCTIONS  
CustomSer  
vice  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
About the controls on the air conditioner.  
The controls will look like one of the following.  
uctions  
OFF  
OFF  
HIGH  
FAN  
HIGH  
COOL  
HI  
FAN  
HI  
COOL  
SafeyInstr  
LOW  
FAN  
MED  
COOL  
LOW  
FAN  
LOW  
COOL  
LOW  
COOL  
uctions  
MODE CONTROLS  
5
4
5
6
3
4
4
7
8
9
3
6
OpeaigInstr  
2
5
3
2
7
2
1
8
1
6
1
10  
uctions  
TEMP CONTROLS  
laioInstr  
Controls  
Mode Controls  
Temp Controls  
ips  
HIGH COOL, MED COOL and LOW COOL provide  
The temp control is used to maintain the  
room temperature. The compressor will cycle  
on and off to keep the room at the same level  
of comfort. When you turn the knob to a  
higher number the indoor air will become  
cooler. Turn the knob to a lower number and  
the indoor air will become warmer.  
cooling with different fan speeds.  
LOW FAN or HIGH FAN provides air circulation  
and filtering without cooling.  
NOTE: If you move the switch from a cool setting to OFF or to  
a fan setting, wait at least 3 minutes before switching back to  
a cool setting.  
ubleshotingT  
r
T
Cooling Descriptions  
For Normal Cooling—Select HIGH COOL or MED  
COOL with the temp control  at  midpoint.  
For Maximum Cooling—Select HIGH COOL with the  
temp control at the highest number available on  
your knob.  
vice  
For Quieter & Nighttime Cooling—Select LOW COOL  
with the temp control at midpoint.  
CustomSer  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SafeyInstr  
Additional controls and important information.  
uctions  
Energy Saver (on some models)  
The energy saver switch controls the fan.  
ENERGY SAVER OFF—The fan runs all the time, while  
the compressor cycles on and off.  
ENERGY SAVER ON—The fan and compressor cycle  
on and off together. This results in wider variations  
of room temperature and humidity.  
OpeaigInstr  
Vent Control  
The vent control is located above the control knobs.  
When set at CLOSE, only the air inside the room will  
be circulated and conditioned. When set at OPEN,  
some inside air is exhausted outside.  
uctions  
laioInstr  
To open the vent, pull the lever toward you.  
To close it, push it in.  
Air Direction  
uctions  
The horizontal air direction is adjusted by moving  
the lever to the left or right.  
Fingertip pressure on the horizontal louvers adjusts  
the air direction up or down.  
T
r
ubleshotingT  
ips  
CustomSer  
vice  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Care and cleaning of the air conditioner.  
uctions  
Grille and Case  
Turn the air conditioner off and remove the plug To clean, use water and a mild detergent. Do not  
from the wall outlet before cleaning.  
use bleach or abrasives.  
SafeyInstr  
Outdoor Coils  
The coils on the outdoor side of the air conditioner  
should be checked regularly. If they are clogged  
with dirt or soot they may be professionally steam  
cleaned, a service available through your GE  
service outlet.  
uctions  
OpeaigInstr  
Air Filter  
uctions  
The air filter behind the front grille should be  
checked and cleaned at least every 30 days or more  
often if necessary.  
To remove:  
Open the inlet grille upward by pulling out the  
bottom of the inlet grille.  
1
Using the tab, pull up slightly on the filter to  
release it and pull it down.  
laioInstr  
2
ips  
Clean the filter with warm, soapy water. Rinse and  
let the filter dry before replacing it.  
CAUTION: DO NOT operate the air conditioner without a  
filter because dirt and lint will clog it and reduce performance.  
ubleshotingT  
r
T
vice  
CustomSer  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SafeyInstr  
Preparing to install the air conditioner.  
Read these instructions completely and carefully.  
uctions  
Before You Begin  
NOTE TO INSTALLER: Leave these instructions with  
CAUTION:  
the air conditioner after installation is completed.  
Do not, under any circumstances, cut or  
remove the third (ground) prong from the  
power cord.  
NOTE TO CONSUMER: Keep this Owners Manual  
and Installation Instructions for future use.  
OpeaigInstr  
Do not change the plug on the power cord  
of this air conditioner.  
IMPORTANT NOTES:  
For personal safety, this air conditioner must be  
properly grounded.  
Aluminum house wiring may present  
special problems—consult a qualified  
electrician.  
It is important to have the wall outlet and circuit  
checked by a qualified electrician if there is any  
doubt as to whether a proper ground exists.  
uctions  
Follow National Electric Codes (NEC) and/or local  
codes and ordinances.  
laioInstr  
Electrical Requirements  
This model requires a 115/120-volt a.c.,  
60 Hz grounded outlet protected with  
a 15-amp time delay fuse or circuit breaker.  
The 3-prong grounding plug minimizes the  
possibility of electric shock hazard. If the wall outlet  
you plan to use is only a 2-prong outlet, it is your  
responsibility to have it replaced with a properly  
grounded 3-prong wall outlet.  
uctions  
T
r
ubleshotingT  
Tools You Will Need  
Phillips-head screwdriver  
Flat-blade screwdriver  
Scissors or knife  
Pencil  
Level  
Ruler or tape measure  
ips  
CustomSer  
vice  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Window Installation Instructions  
Parts Included  
uctions  
Top mounting rail  
Window  
sash seal  
SafeyInstr  
Left  
accordion  
panel  
Foam top  
window gasket  
Top mounting rail  
seal strip  
uctions  
OpeaigInstr  
Right  
uctions  
accordion  
panel  
Frame guide (2)  
laioInstr  
Sill support (2)  
ips  
Window locking  
bracket  
Type B (3)  
Type C (5)    
Type A (16)    
Nut (2)  
Bolt (2)  
ubleshotingT  
r
T
vice  
CustomSer  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
SafeyInstr  
Read completely, then follow step-by-step.  
uctions  
Window Requirements  
These instructions are for a standard double-  
hung window. You will need to modify them for  
other types of windows.  
1
The air conditioner can be installed without the  
accordion panels if needed to fit in a narrow  
window. See the window opening dimensions to  
the right.  
OpeaigInstr  
14² min.  
25² to 36²  
(With accordion panels)  
All supporting parts must be secured to firm  
wood, masonry or metal.  
The electrical outlet must be within reach of the  
power cord.  
uctions  
1
8
20 / ²min.  
(Without accordion panels)  
Window opening dimensions are for a standard double-hung  
window.  
laioInstr  
Storm Window Requirements  
A storm window frame will not allow the air  
conditioner to tilt towards the outside and will keep  
it from draining properly. To adjust for this, attach a  
piece of wood to the stool.  
WOOD PIECES—  
2
WIDTH: 2²  
LENGTH: Long enough to fit inside the window  
frame.  
Wood  
uctions  
1/2² higher  
than frame  
THICKNESS: To determine the thickness, place a  
piece of wood on the stool to make it 1/2² higher  
than the top of the storm window frame.  
Stool  
Storm window  
frame  
Attach securely with nails or screws provided by  
the installer.  
T
r
ubleshotingT  
ips  
CustomSer  
vice  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
Window Installation Instructions  
uctions  
Remove the Air Conditioner From the Case  
Remove the 2 shipping screws from the back of  
Slide the air conditioner from the case by  
gripping the base pan handle and pulling  
forward while bracing the case.  
3
A
C
the case.  
SafeyInstr  
Remove the 2 screws on each side of the case.  
Keep these for later use.  
B
Shipping screws  
uctions  
OpeaigInstr  
uctions  
Prepare the Window and the Case  
Cut the window sash seal to the proper length.  
Peel off the backing and attach the seal to the  
underside of the window sash.  
Remove the backing from the top mounting  
rail seal strip and attach it to the bottom of the  
top mounting rail.  
4
A
C
laioInstr  
ips  
Install the top mounting rail with 3 type A  
screws on the inside of the case. Insert the  
frames for the accordion panels into the top  
mounting rail and the frame guides. Attach the  
accordion panels to the side of the case using  
4 type A screws.  
D
Carefully insert the plastic frame guides into  
the bottom of the case on each side.  
B
ubleshotingT  
r
T
Top mounting rail  
Bottom of case  
vice  
Frame guide  
CustomSer  
Frame guides  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SafeyInstr  
uctions  
Install the Case in the Window  
Open the window and mark the centerline of  
Adjust the bolt and the nut in each support so  
that the case is installed with a slight downward  
tilt (about 1/8²).  
5
A
F
the window stool.  
Carefully place the case on the window stool  
B
and align the center mark on the bottom front  
Secure the case to the window stool by using 3  
type B screws.  
G
with the centerline of the stool.  
OpeaigInstr  
Pull the window down behind the top  
mounting rail.  
C
uctions  
Sill  
support  
laioInstr  
Pull the accordion panels to each window  
H
sash track. Attach them on each side to the  
window sash and the window stool using  
4 type C screws.  
NOTE: Do not shut the window so tightly that movement of  
the accordion panels is restricted.  
Loosely assemble the sill supports.  
uctions  
D
INDOOR  
OUTDOOR  
Sill support  
T
r
ubleshotingT  
Bolt  
Nut  
Select the position that will place the sill  
supports near the outermost point on the sill.  
Attach the sill supports to the case track hole in  
relation to the selected position using 2 type A  
screws in each support.  
E
ips  
Frame guide  
CustomSer  
vice  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Window Installation Instructions  
uctions  
Install the Window Locking Bracket and the Foam Top Window Gasket  
Attach the window locking bracket with a  
type C screw.  
Cut the foam top window gasket to the window  
width.  
A
B
C
6
7
SafeyInstr  
Stuff the foam between the glass and the  
window to prevent air and insects from getting  
into the room.  
uctions  
OpeaigInstr  
Install the Air Conditioner in the Case  
Slide the air conditioner into the case.  
Attach the front grille to the case by inserting the  
tabs on the grille into the slots on the front of the  
case. Push the grille in until it snaps into place.  
uctions  
A
C
Reinstall the 2 screws removed earlier on each  
side of the case.  
Before installing the front grille, pull out the  
B
vent control lever located above the unit  
control knobs, as shown.  
laioInstr  
ips  
Guide the lever carefully  
through the grille as you  
push it in.  
ubleshotingT  
r
T
Lift the inlet grille and secure it with a type A  
screw through the front grille.  
D
vice  
CustomSer  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SafeyInstr  
Before you call for service…  
Troubleshooting Tips  
Save time and money! Review the chart below first and  
you may not need to call for service.  
uctions  
Problem  
Possible Causes  
What To Do  
Air conditioner  
does not start  
The air conditioner  
is unplugged.  
Make sure the air conditioner plug is pushed  
completely into the outlet.  
OpeaigInstr  
The fuse is blown/circuit  
breaker is tripped.  
Check the house fuse/circuit breaker box and replace  
the fuse or reset the breaker.  
Power failure.  
If power failure occurs, turn the mode control to OFF.  
When power is restored, wait 3 minutes to restart the  
air conditioner to prevent tripping of the compressor  
overload.  
uctions  
Air conditioner does  
not cool as it should  
Airflow is restricted.  
Make sure there are no curtains, blinds or furniture  
blocking the front of the air conditioner.  
The temp control may  
not be set high enough.  
Turn the knob to a higher number. The highest setting  
provides maximum cooling.  
laioInstr  
The air filter is dirty.  
Clean the filter at least every 30 days.  
See the Operating Instructions section.  
The room may have been hot.  
Cold air is escaping.  
When the air conditioner is first turned on you need to  
allow time for the room to cool down.  
Check for open furnace floor registers and cold  
air returns.  
uctions  
Set the air conditioner’s vent to the closed position.  
See “Air conditioner freezing up” below.  
Cooling coils have iced up.  
Air conditioner  
freezing up  
Ice blocks the air flow  
and stops the air conditioner  
from cooling the room.  
Set the mode control at HIGH FAN or HIGH COOL  
with the temp at 1 or 2.  
T
r
ubleshotingT  
Normal Operating Sounds  
You may hear a pinging noise caused by water  
being picked up and thrown against the  
Water will collect in the base pan during  
high humidity or on rainy days. The water  
condenser on rainy days or when the humidity is  
high. This design feature helps remove moisture  
and improve efficiency.  
may overflow and drip from the outdoor side  
of the unit.  
ips  
The fan may run even when the compressor  
You may hear the thermostat click when the  
is not.  
compressor cycles on and off.  
CustomSer  
vice  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Notes  
uctions  
SafeyInstr  
uctions  
OpeaigInstr  
uctions  
laioInstr  
ips  
ubleshotingT  
r
T
vice  
CustomSer  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SafeyInstr  
Air Conditioner Warranty  
All warranty service provided by our Factory Service Centers,  
or an authorized Customer Care® technician. For service,  
call 800-GE-CARES.  
uctions  
For The Period Of:  
GE Will Replace, At No Charge To You:  
One Year  
From the date of the  
original purchase  
Any part of the air conditioner which fails due to a defect in materials or workmanship.  
During this full one-year warranty, GE will also provide, free of charge, all labor  
and in-home service to replace the defective part.  
OpeaigInstr  
Five Years  
From the date of the  
original purchase  
Any part of the sealed refrigerating system (the compressor, condenser, evaporator  
and all connecting tubing) which fails due to a defect in materials or workmanship.  
During this five-year warranty, GE will also provide, free of charge, all labor and  
in-home service to replace the defective part.  
uctions  
What GE Will Not Cover:  
Service trips to your home to teach you how to use the  
product.  
Replacement of house fuses or resetting of circuit  
breakers.  
laioInstr  
Improper installation. If you have an installation problem, Failure due to corrosion on models not corrosion-  
or if the air conditioner is of improper cooling capacity  
for the intended use, contact your dealer or installer. You  
are responsible for providing adequate electrical  
connecting facilities.  
protected.  
Damage to the product caused by improper power supply  
voltage, accident, fire, floods or acts of God.  
Incidental or consequential damage to personal property  
caused by possible defects with this air conditioner.  
Failure of the product resulting from modifications to the  
product or due to unreasonable use including failure to  
provide reasonable and necessary maintenance.  
uctions  
In commercial locations labor necessary to move the unit  
to a location where it is accessible for service by an  
individual technician.  
T
r
This warranty is extended to the original purchaser and any succeeding owner for products purchased for home  
use within the USA. In Alaska, the warranty excludes the cost of shipping or service calls to your home.  
ubleshotingT  
Some states do not allow the exclusion or limitation of incidental or consequential damages. This warranty gives  
you specific legal rights, and you may also have other rights which vary from state to state. To know what your  
legal rights are, consult your local or state consumer affairs office or your states Attorney General.  
ips  
Warrantor: General Electric Company. Louisville, KY 40225  
CustomSer  
vice  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Service Telephone Numbers.  
GE Answer Center® 800.626.2000  
uctions  
The GE Answer Center® is open 24 hours a day, 7 days a week.  
SafeyInstr  
In-Home Repair Service 800-GE-CARES (800-432-2737)  
Expert GE repair service is only a phone call away.  
uctions  
Special Needs Service 800.626.2000  
800-TDD-GEAC (800-833-4322)  
GE offers, free of charge, a brochure to assist in planning a barrier-free kitchen for persons  
with limited mobility.  
OpeaigInstr  
Service Contracts 800-626-2224  
Purchase a GE service contract while your warranty is still in effect and you’ll receive a  
substantial discount. GE Consumer Service will still be there after your warranty expires.  
uctions  
Parts and Accessories 800-626-2002  
Individuals qualified to service their own appliances can have parts or accessories sent directly  
to their homes (VISA, MasterCard and Discover cards are accepted).  
laioInstr  
Instructions contained in this manual cover procedures to be performed by any user. Other servicing  
generally should be referred to qualified service personnel. Caution must be exercised, since  
improper servicing may cause unsafe operation.  
ips  
Service Satisfaction  
If you are not satisfied with the service you receive from GE:  
First, contact the people who serviced your appliance.  
Next, if you are still not pleased, write all the details—including your phone number—to:  
ubleshotingT  
r
T
Manager, Consumer Relations  
GE Appliances  
Appliance Park  
Louisville, KY 40225  
Finally, if your problem is still not resolved, write:  
vice  
Major Appliance Consumer Action Program  
20 North Wacker Drive  
Chicago, IL 60606  
CustomSer  
Printed in Korea  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Eiki Network Card EZ WDVA User Manual
Esoteric CD Player X 03 User Manual
Evo Fitness Elliptical Trainer REV 400 User Manual
Franke Consumer Products Oven GL 62 M XS User Manual
Friedrich Air Conditioner C24YF User Manual
Frigidaire Microwave Oven 316495055 User Manual
Fujitsu Scanner fi 4750C User Manual
Garmin GPS Receiver TRAILManual User Manual
GE Monogram Trash Compactor ZCG3500DSS User Manual
Genius Scanner 1200XE User Manual