Furuno SONAR ch250s User Manual

Installation Manual  
SEARCHLIGHT SONAR  
CH-250/CH-250S  
3. ADJUSTMENTS ...............................31  
SAFETY INSTRUCTIONS....................... i  
3.1 General Checks..................................... 31  
3.2 TX Frequency Checking........................ 32  
3.3 Heading Adjustment/Soundome Setting  
......................................................... 34  
SYSTEM CONFIGURATION................. iii  
EQUIPMENT LISTS .............................. iv  
1. Mounting ........................................... 1  
1.1 Monitor Unit/Control Unit..........................1  
1.2 Transceiver Unit.......................................6  
1.3 Hull Unit ...................................................9  
1.4 Interface Unit..........................................21  
1.5 Motion Sensor MS-100 (option).............22  
3.4 Adjustment of Motion Sensor ................ 37  
3.5 System Back Up.................................... 38  
3.6 Setting of Interface Unit......................... 40  
Input/Output Description....................41  
PACKING LISTS ................................ A-1  
OUTLINE DRAWINGS ....................... D-1  
INTERCONNECTION DIAGRAMS..... S-1  
2. Wiring .............................................. 23  
2.1 Wiring among Units................................23  
2.2 Transceiver Unit.....................................26  
2.3 Hull Unit .................................................29  
2.4 Interface Unit..........................................30  
All brand and product names are trademarks, registered trademarks or service marks of their respective holders.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SAFETY INSTRUCTIONS  
Read these safety instructions before you operate the equipment.  
Indicates a condition that can cause death or serious  
injury if not avoided.  
WARNING  
Indicates a condition that can cause minor or moderate  
injury if not avoided.  
CAUTION  
Warning, Caution  
Mandatory Action  
Prohibitive Action  
WARNING  
WARNING  
Installe the specified transducer tank  
in accordance with the installation  
instructions. If a different tank is to be  
installed the shipyard is solely respon-  
sible for its installation, and it should  
be installed so the tank doesn't strike  
an object.  
ELECTRICAL SHOCK HAZARD  
Do not open the equipment.  
Only qualified personnel  
should work inside the  
equipment.  
Turn off the power at the switchboard  
before beginning the installation.  
The tank or hull may be damaged if the  
tank strikes an object.  
Fire or electrical shock can result if the  
power is left on.  
If a steel tank is installed on a wooden  
or FRP vessel, take appropriate  
measures to prevent electrolytic  
corrosion.  
Do not install the equipment where it  
may get wet from rain or water splash.  
Electrolytic corrosion can damage the hull.  
Water in the equipment can result in fire,  
electrical shock or equipment damage.  
Be sure that the power supply is  
compatible with the voltage rating of  
the equipment.  
Be sure no water leaks in at the transdu-  
cer installation site.  
Connection of an incorrect power supply  
can cause fire or equipment damage.  
The voltage rating of the equipment appears  
on the label above the power connector.  
Water leakage can sink the vessel.  
Also confirm that the transducer will not  
loosen by ship's vibration.  
The installer of the equipment is solely  
responsible for the proper installation of the  
equipment. FURUNO will assume no  
responsibility for any damage  
associated with improper installation.  
i
Download from Www.Somanuals.com. All Manuals Search And Download.  
CAUTION  
Ground the equipment to  
prevent electrical shock and  
mutual interference.  
CAUTION  
WORKING WITH THE SONAROIL  
Precautions  
Keep oil away from eyes. Wear protective  
gloves when working with the oil. The oil  
can cause inflammation of the eyes.  
Observe the following compass safe  
distances to prevent deviation of a  
magnetic compass:  
Do not touch the oil. Wear protective  
gloves when working with the oil. The oil  
can cause inflammation of the skin.  
Standard Steering  
0.80 m  
0.55 m  
Monitor unit/  
Control unit  
Do not ingest the oil. Diarrhea or vomiting  
can result.  
Transceiver  
unit  
0.50 m  
0.95 m  
0.35 m  
0.65 m  
Keep the oil out of reach of children.  
Interface  
unit  
Emergency  
If the oil enters eyes, flush with clean  
water about 15 min. Consult a physician.  
Install the monitor unit MU-100C out of  
direct sunlight.  
If the oil contacts skin, wash within soap  
and water.  
It is difficult to see the display in direct  
sunlight.  
If the oil is ingested, see a physician  
immediately.  
Turn the main power off before this check,  
otherwise the raise/lower motor action  
may cause injurely  
Disposal of oil and its container  
Dispose of oil and its container in  
accordance with local regulations.  
For further details, contact place of  
purchase.  
Storage  
Seal container to keep out foreign  
material. Store in dark place.  
ii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SYSTEM CONFIGURATION  
INTERFACE UNIT IF-8000  
Note 2  
MONITOR UNIT MU-100C  
Navigator  
Control Unit  
Note 1  
Note 2  
Display  
Unit  
VGA Ext.  
Monitor  
Remote  
Controller  
TRANSCEIVER UNIT  
CH-253  
CONTROL UNIT CH-252  
MOTION SENSOR  
12-32 VDC  
HULL UNIT  
SPEAKER  
DATA/VIDEO OUT  
HULL UNIT  
CH-254/254S  
CH-255/255S  
12-32 VDC  
Speaker  
Motion Sensor  
12/24-32 VDC  
Note 1: MU-100C is the standard supply  
display unit. An external monitor  
may be connected via the  
interface unit (option). The drawing  
above shows the system configuration  
with the MU-100C.  
Note 2: For blackbox type, MU-100C is  
not supplied. Connect external  
monitor (user supply) and control  
unit to the interface unit.  
iii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
EQUIPMENT LISTS  
Standard Supply  
Name  
Type  
Code no.  
Qty Remarks  
Control Unit/  
Monitor Unit  
Control Unit  
Interface Unit  
Transceiver Unit  
CH-252/  
MU-100C  
CH-252  
IF-8000  
CH-253  
CH-254  
CH-254S  
CH-255  
CH-255S  
1
Not supplied with blackbox type  
1
1
1
Not supplied with unibody type  
For blackbox type  
400 stroke  
250 stroke  
See the following  
table for Hull Unit  
Standard Supply.  
1
Hull Unit  
For unibody type, SP06-01102*,  
SP06-01103*  
For blackbox type, SP06-01102*,  
SP06-01111*, SP06-01103*  
For unibody type  
SP06-01100  
000-068-488  
1
Spare Parts  
SP06-01110  
SP06-01101*  
000-068-489  
006-556-200  
Installation  
Materials  
CP06-01251* and two cables (page  
viii)  
For unibody type, FP02-05101*,  
FP06-01102*  
For blackbox type  
Hard cover  
1
1
1
FP02-05100  
FP06-01120*  
06-021-2121  
000-012-474  
006-556-260  
100-320-101  
Accessories  
For blackbox type  
*: See the lists at the back of this manual.  
iv  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hull Unit (1)  
Code no.  
Type  
Spec.  
Stroke  
400 mm  
Power  
12 V  
Frequency  
60 kHz  
88 kHz  
150 kHz  
180 kHz  
240 kHz  
60 kHz  
Shaft  
2.2 m  
Cable  
3.5 m  
000-068-515  
000-068-516  
000-068-517  
000-068-518  
000-068-519  
000-068-559  
000-068-560  
000-068-561  
000-068-562  
000-068-563  
000-068-520  
000-068-521  
000-068-522  
000-068-523  
000-068-524  
000-068-525  
000-068-526  
000-068-527  
000-068-528  
000-068-529  
000-068-564  
000-068-565  
000-068-566  
000-068-567  
000-068-568  
000-068-530  
000-068-531  
000-068-532  
000-068-533  
000-068-534  
000-068-535  
000-068-536  
000-068-537  
000-068-538  
000-068-539  
000-068-540  
000-068-543  
000-068-544  
000-068-547  
000-068-548  
000-068-569  
000-068-570  
000-068-571  
000-068-572  
000-068-573  
000-068-549  
000-068-550  
000-068-551  
000-068-552  
000-068-553  
000-068-554  
000-068-555  
000-068-556  
000-068-557  
000-068-558  
000-068-574  
000-068-575  
000-068-576  
000-068-577  
000-068-578  
CH-254-1-60-22-35  
CH-254-1-88-22-35  
CH-254-1-150-22-35  
CH-254-1-180-22-35  
CH-254-1-240-22-35  
CH-254-1-60-22-52  
CH-254-1-88-22-52  
CH-254-1-150-22-52  
CH-254S-1-180-22-52  
CH-254S-1-240-22-52  
CH-254-1-60-38-52  
CH-254-1-88-38-52  
CH-254-1-150-38-52  
CH-254S-1-180-38-52  
CH-254S-1-240-38-52  
CH-254-2-60-22-35  
CH-254-2-88-22-35  
CH-254-2-150-22-35  
CH-254S-2-180-22-35  
CH-254S-2-240-22-35  
CH-254-2-60-22-52  
CH-254-2-88-22-52  
CH-254-2-150-22-52  
CH-254S-2-180-22-52  
CH-254S-2-240-22-52  
CH-254-2-60-38-52  
CH-254-2-88-38-52  
CH-254-2-150-38-52  
CH-254S-2-180-38-52  
CH-254S-2-240-38-52  
CH-255-1-60-22-35  
CH-255-1-88-22-35  
CH-255-1-150-22-35  
CH-255S-1-180-22-35  
CH-255S-1-240-22-35  
CH-255-1-60-38-52  
CH-255-1-88-38-52  
CH-255-1-150-38-52  
CH-255S-1-180-38-52  
CH-255S-1-240-38-52  
CH-255-1-60-22-52  
CH-255-1-88-22-52  
CH-255-1-150-22-52  
CH-255S-1-180-22-52  
CH-255S-1-240-22-52  
CH-255-2-60-22-35  
CH-255-2-88-22-35  
CH-255-2-150-22-35  
CH-255S-2-180-22-35  
CH-255S-2-240-22-35  
CH-255-2-60-38-52  
CH-255-2-88-38-52  
CH-255-2-150-38-52  
CH-255S-2-180-38-52  
CH-255S-2-240-38-52  
CH-255-2-60-22-52  
CH-255-2-88-22-52  
CH-255-2-150-22-52  
CH-255S-2-180-22-52  
CH-255S-2-240-22-52  
2.2 m  
3.8 m  
2.2 m  
2.2 m  
3.8 m  
2.2 m  
3.8 m  
2.2 m  
2.2 m  
3.8 m  
2.2 m  
5.2 m  
5.2 m  
3.5 m  
5.2 m  
5.2 m  
3.5 m  
5.2 m  
5.2 m  
3.5 m  
5.2 m  
5.2 m  
88 kHz  
150 kHz  
180 kHz  
240 kHz  
60 kHz  
88 kHz  
150 kHz  
180 kHz  
240 kHz  
60 kHz  
24 V-32 V  
88 kHz  
150 kHz  
180 kHz  
240 kHz  
60 kHz  
88 kHz  
150 kHz  
180 kHz  
240 kHz  
60 kHz  
88 kHz  
150 kHz  
180kHz  
240 kHz  
60 kHz  
250 mm  
12 V  
88 kHz  
150 kHz  
180 kHz  
240 kHz  
60 kHz  
88 kHz  
150 kHz  
180 kHz  
240kHz  
60 kHz  
88 kHz  
150 kHz  
180 kHz  
240 kHz  
60 kHz  
24 V-32 V  
88 kHz  
150 kHz  
180 kHz  
240 kHz  
60 kHz  
88 kHz  
150 kHz  
180 kHz  
240 kHz  
60 kHz  
88 kHz  
150 kHz  
180 kHz  
240 kHz  
v
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hull Unit Standard Supply  
Name  
Type  
Code no.  
Qty  
1 set  
Remarks  
CH-2541  
CH-2541S  
CH-2551  
CH-2551S  
CH-2542  
CH-2542S  
CH-2543  
-
-
-
-
-
-
Raise/lower  
Drive Unit  
See the following Soudome  
table.  
Flange, grease cotton  
Shaft, retraction tank, seal,  
adhesives, tank guide,  
material box  
Soundome  
Flange  
1 set  
1 set  
006-557-810  
Assembly Kit for  
field  
CH-2544  
006-557-820  
1 set  
Shaft  
SHJ-0006-1  
06-007-1572-0  
4 lit.  
661-000-061  
600-715-720  
000-824-033  
2.2 m, for 3.5/5.2 m cable  
3.8 m, for 5.2m cable  
1
1
Sonar Oil  
vi  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Shaft parts  
Name  
Type  
SHN-0011-0  
1X28-41  
M10X35 SUS304 000-862-175  
M10 SUS304  
M10 SUS304  
Code no.  
661-400-110  
000-801-857  
Qty  
1
1
2
2
Remarks  
Pipe cap  
Jubilee Clip  
Hex. bolt  
U-nut  
000-863-930  
000-864-131  
Flat washer  
4
Tank parts  
Name  
Hex. bolt  
Type  
Code no.  
Qty  
8
Remarks  
M20X80 SUS304 000-801-893  
Hex. nut  
Flat washer  
Spring washer  
M20 SUS304  
M20 SUS304  
M20 SUS304  
000-863-116  
000-864-136  
000-864-270  
16  
16  
8
Adhesives  
Name  
Kinolastar  
Three Bond  
Type  
855  
1104  
Code no.  
Qty  
1
1
Remarks  
000-801-328  
000-854-104  
000-856-520  
Anti-corrosion  
Sealant, 200g  
adhesive  
Cemedine High Super  
6G  
1
Tank guide  
Name  
Tank guide  
Type  
CH-2544  
Code no.  
006-557-200  
Qty  
1
Remarks  
Assembly kit for field (Material Box)  
Name Type  
Socket set screw TWB-40  
Code no.  
Qty  
Remarks  
4 mm  
0.5 mm  
1.0 mm  
2.0 mm  
000-804-423  
100-295-420  
100-295-430  
100-295-440  
1
Shim (0.5)  
Shim (1.0)  
Shim (2.0)  
06-021-4035  
06-021-4036  
06-021-4037  
2
2
4
vii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Cables for Installation materials  
Type  
Code no.  
Specification (Cable between unit)  
Monitor unit (or IF)  
and Transceiver unit  
06S4078*5m*  
Transceiver unit and Hull unit  
Crimp-on lug  
CP06-01200  
CP06-01201  
CP06-01202  
CP06-01203  
CP06-01204  
CP06-01205  
000-068-496  
000-068-497  
000-068-498  
000-068-499  
000-068-500  
000-068-502  
06S4080*15m*  
06S4080*30m*  
06S4080*50m*  
06S4080*15m*  
06S4080*30m*  
06S4080*50m*  
CP06-01251*  
CP06-01251*  
CP06-01251*  
CP06-01251*  
CP06-01251*  
CP06-01251*  
06S4078*10m*  
Control unit cable  
Type  
Code no.  
Qty  
1
Remarks  
CP02-06600*  
CP02-06610*  
CP02-06620*  
000-012-486  
000-012-480  
000-012-481  
MJ-A10SPF0002-0015, for unibody type  
MJ-A10SPF0002-015, 1.5 m  
1
For blackbox type  
MJ-A10SPF0002-050, 5 m  
*: See lists at the back of this manual.  
Options  
Name  
Type  
Code no.  
Qty  
1 set  
1 set  
1 set  
1
Remarks  
Remote Controller CH-256-E  
000-068-492  
000-068-495  
-
Interface Unit  
Motion Sensor  
Speaker  
Signal Cable  
Cable assy.  
IF-8000  
MS-100  
SC-05WR  
S06-9-5  
MJ-A6SSPF0012-050  
MJ-A6SSPF0012-100  
MJ-A6SSPF0011-050  
MJ-A6SSPF0011-100  
OP06-15-1.5 NEW  
OP06-15-5 NEW  
OP02-83-1.5  
000-136-156  
006-556-270  
000-134-424  
000-133-817  
000-132-244  
000-132-336  
006-559-140  
006-559-150  
001-413-600  
001-413-610  
006-556-300  
006-556-310  
006-556-320  
1
1
Extension cable for speaker  
6pin-6pin, 5m  
6pin-6pin, 10m  
6pin-4pin, 5m  
6pin-4pin, 10m  
For desktop, with 1.5 m  
For desktop, with 5 m  
For flush mount, with 1.5 m cable  
For flush mount, with 5m cable  
For unibody type  
Control Unit  
Separate Kit  
1
1
1
1
1
1
OP02-83-5  
OP06-16  
OP06-17  
OP06-18  
Flush mount kit  
For separate type display unit  
Control unit flush  
mount kit  
Rectifier  
RU-1746B-2  
06-007-1570-1  
SHJ-0001-1  
06-007-1571-1  
06-021-4024-0  
06-007-1573-0  
OP10-5  
000-030-439  
600-715-701  
661-000-011  
600-715-711  
100-295-470  
600-715-730  
000-069-763  
1
1
1
1
1
1
1
Tank  
Steel, 1m  
Steel, 1.8m  
Steel, 3.5m  
FRP, 1m  
FRP, 1.8m  
Aluminum, 1m  
Fairing  
06-021-4502  
001-159-790-10 1 set For an FRP ship  
viii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Mounting  
NOTICE  
Do not apply paint, anti-corrosive sealant  
or contact spray to coating or plastic  
parts of the equipment.  
Those items contain organic solvents that  
can damage coating and plastic parts,  
especially plastic connectors.  
1.1 Monitor Unit/Control Unit  
This searchlight sonar has two types of shipment, standard type which is shipped with monitor  
unit and blackbox type which is shipped without monitor unit, but has interface unit. For  
blackbox type, see page 4.  
The control unit can be installed together with the monitor unit, or independently of the monitor  
unit. On installing separately, the optional monitor kit is required. These units can be installed on  
a tabletop or flush mounted in a console or panel.  
1.1.1 General mounting considerations  
Keep the monitor unit out of direct sunlight.  
Select a location where the unit(s) can easily be operated while observing the fishing ground  
or area surrounding the vessel.  
For maintenance and checking purposes, leave sufficient space at the sides and rear of the  
unit and leave slack in cable. (Refer to the outline drawing at the back of this manual.)  
A magnetic compass will be affected if place too close to the monitor unit. Observe the  
following compass safe distance to prevent deviation to a magnetic compass: Standard  
compass: 0.80 m, Steering compass: 0.55 m.  
1.1.2 Mounting method of monitor unit (Standard type)  
1. Fasten the mounting base to the mounting location with four tapping screws.  
FRONT  
Mounting base  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
2. For unibody mounting;  
a) Fasten the bracket at the rear of monitor and control units with four binding screws (M4x10).  
Bracket (rear view)  
1
2
1
3
2
4
3
4
Bracket, rear view  
3. For separate/blackbox mounting;  
a) Dismount the coupling plate to separate monitor unit and control unit.  
b) Attach the bracket at rear of the monitor unit with four binding screws (M4x10).  
Bracket (rear view)  
1
2
1
2
4
3
4
3
Bracket, rear view  
4. Coat threads of upset screws (M6x16, 2 pcs.) used to fasten bracket to mounting base.  
5. Fasten the bracket to the mounting base with two upset screws. (Use the upper holes to tilt  
the monitor unit 20°; lower holes to tilt it 9°.)  
MOUNTING  
BASE  
HANGER  
Upset Screw  
Fastening hanger to mounting base  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
Flush mounting  
Flush mounting for unibody (Type: OP06-16, Code no.: 006-556-300)  
Name  
Type  
Code No.  
Qty  
1
Remarks  
Fixing metal  
06-021-1311-2 100-279-612-10  
Self-tapping screw 5x20  
Hex. bolt M4x12  
000-162-609-10  
000-162-939-10  
6
4
1. Make holes at the place to mount (W287 x H297).  
2. Fasten monitor and control units with the fixing metal (supplied as option) and four hex.  
bolts (supplied as option).  
3. Fasten the fixing metal assembled at step 2 to holes made at step 1 with six tapping screws  
(supplied as option).  
Hex. Bolts  
Fixing metal  
Flush mounting for monitor unit (Type: OP06-17, Code no. 006-556-310)  
Name  
Fixing metal  
Self-tapping screw  
Hex. bolt  
Type  
Code No.  
Qty  
1
Remarks  
06-021-1321-2 100-279-622-10  
5x20  
000-162-609-10  
000-162-939-10  
4
M4x12  
4
1. Make holes at the place to mount (W287 x H207).  
2. Fasten the fixing metal (supplied as option) to the monitor unit with four hex. bolts (M4x12,  
supplied as option).  
3. Fasten the fixing metal assembled at step 2 to holes made at step 1 with four tapping  
screws (5x20, supplied as option).  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hex. Bolts  
Fixing Metal  
Flush mounting for control unit Type:  
OP02-83-1.5, Code no.: 001-413-600 (1.5 m cable)  
OP03-83-5, Code no.: 001-413-610 (5m cable)  
Name  
Type  
Code No.  
Qty  
1
Remarks  
Fixing metal  
06-021-2101-2  
100-279-732-10  
000-162-609-10  
000-162-939-10  
000-142-878  
Self-tapping screw 5x20  
4
Hex. bolt  
M4x12  
2
MJ-A10SPF0002-0  
15  
Cable assembly  
1
1.5 m Select one.  
5 m  
MJ-A10SPF0002-0  
50  
000-131-411  
1
1. Make holes at the place to mount (W287 x H87).  
2. Fasten the fixing metal to the control unit with two hex. bolts (supplied as option).  
3. Fasten the fixing metal assembled at step 2 to holes made at step 1 with four tapping  
screws (supplied as option).  
Hex. Bolts  
Fixing metal  
1.1.3 Blackbox type  
The blackbox type is required to connect a standard VGA monitor via the interface unit IF-8000.  
Supply monitor and interconnection cable (Max. length 15 m with Dsub-15P connectors of male,  
three rows of 15 pins) locally. The monitor used should satisfy the specifications shown below.  
VGA type  
ANALOG RGB 0.7 Vpp, positive polarity  
TLL level H, V, Negative polarity  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
1.1.4 Control unit  
On blackbox type, fix the control unit to the mounting plate (supplied as accessories).  
See the parts list of FP06-01120 and outline drawings at the back of this manual.  
1. Fix the mounting plate to the place selected with two tapping screws (5x20, supplied).  
2. Fix the bracket to the control unit with two hex. screws (M4x12, supplied).  
3. Insert the screw driver from the top of the mounting plate holes and then tighten two hex.  
screws (M4x12) loosely.  
4. Attach the control unit to the mounting plate, and fasten two hex. screws tightly.  
5. Attach two cosmetic caps to holes at the top of the mounting plate.  
Mounting plate  
Fasten the screws to fix  
the bracket.  
Cable  
Cable entrance hole  
Tapping screws (5x20)  
Insert to the hex.  
screws tightened  
at step 3.  
Bracket  
Bracket  
Cable can be passed this direction.  
6. Attach hard cover to protect the control unit.  
How to remove the hard cover  
Place your thumbs at the locations shown with  
circles in the illustration at right, and then lift the  
cover while pressing it with your thumbs.  
On mounting the control unit separate from the monitor unit, the optional control unit separate kit  
is required. Mount the control unit same as the above procedure. See the outline drawing at the  
back of this manual to mount.  
Type: OP06-15-1.5 NEW Code no.: 006-559-140: with 1.5 m cable  
Type: OP06-15-5 NEW  
Name  
Code no.: 006-559-150: with 5 m cable  
Type Code no.  
000-142-878  
Qty  
1
Remarks  
For 1.5 m cable  
For 5 m cable  
Cable  
MJ-A10SPF0002-015  
MJ-A10SPF0002-050  
06-021-2112  
06-021-2111-1  
5x20  
000-131-411  
Bracket  
100-281-880-10  
100-279-741-10  
000-162-608-10  
000-165-997-10  
000-162-939-10  
000-807-331  
1
1
2
2
4
4
Mounting Plate  
Tapping Screw  
Cosmetic Cap  
Hex. Screw  
Bind Screw  
DP-687  
M4x12  
M4x10  
For monitor  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
1.2  
Transceiver Unit  
1.2.1 General mounting considerations  
The mounting location should be well ventilated and dry.  
The unit can be mounted on bulkhead or the deck.  
Secure the maintenance space shown in drawing below for ease of maintenance and  
service.  
The maximum cable length between the transceiver unit and the raise/lower drive unit cable  
is 50 m.  
The maximum cable length between the transceiver unit and the monitor (interface) unit is  
10 m.  
1.2.3 Mounting method  
Fasten the transceiver unit with four tapping screws (5X20, local supplied).  
For bulkhead mounting, tighten upper tapping screws so there is 5 mm clearance between  
bottom of screw head and bulkhead, and screw slots of the unit. Then fasten lower screws.  
1.3  
Hull Unit  
1.3.1 General mounting considerations  
Noise and air bubbles will affect performance.  
Do not turn on the equipment with the transducer exposed to air. Exposing the transducer to  
air may damage it.  
1.3.2 Installation position considerations  
Discussion and agreement are required with the dockyard and ship owner in deciding the  
location for the hull unit. When deciding the location, take into account the following points:  
Select an area where propeller noise, cruising noise, bubbles and interference from  
turbulence are minimal. Generally, the point at 1/3 to 1/2 of the ship’s length from the bow or  
near the keel is the best. On-the-keel installation is advantageous for minimizing oil  
consumption in comparison with of-the-keel. If the hull unit cannot be installed on the keel,  
the center of the retraction tank should be within 1 meter of the keel to prevent a rolling  
effect.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
1/3  
1/2  
Within 1 meter  
Installation location for hull unit  
Select a place where interference from the transducers of other sounding equipment is  
minimal. The hull unit should be at least 2.5 meters away from the transducers of other  
sounding equipment.  
An obstacle in the fore direction not only causes a shadow zone but also aerated water,  
resulting in poor sonar performance. Be sure to locate the transducer well away from any  
obstacle in the fore direction.  
Mounting method  
A typical mounting method is shown in the outline drawing at the back of this manual. Consult  
ship’s owner, dockyard and user to determine appropriate mounting method. Pay attention to  
safety (strength, watertightness) first, followed by ease of maintenance and inspection.  
1.3.3 Transducer tank  
Tank length  
Wealding bead  
Shorten the transducer tank so the transducer is  
lowered into water as deep as possible. Pay particular  
attention to the tank length Lt. Determine the length of  
the main shaft.  
Length of main shaft = Lt + 200 mm (for 400 stroke)  
Length of main shaft = Lt + 50 mm (for 250 stroke)  
Note : When the retraction tank is constructed locally,  
Wealding bead  
finish it so that welding beads do not protrude on  
the inner surface of the tank. The tank guide will hit  
the bead, burning out the raise/lower motor. Also,  
do not position the welding bead in the ship’s  
fore-aft line.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
For small FRP ship  
For small FRP ship retraction tank should be 2 degrees against ship’s draft. Therefore, this  
creates high water pressure in the tank because of the resistance at the rear of the tank well. To  
solve this problem, attach a fin to the hull at the location shown in figure below.  
Retraction dome  
Bottom of ship  
Fin  
This fin makes a smooth stream in the retraction dome. Attach the fin (height:1-1.5 cm, FRP).  
Mounting of transducer tank  
Install the transducer tank referring to the hull unit outline drawings at the back of this manual.  
Note 1: When making a retraction tank locally, the inside diameter of the retraction tank should  
not be more than φ190±0.5 as shown on outdrawing at the back of this manual. If larger,  
the hull unit may be danger.  
Note 2: Locate the retraction tank so that the center of any two bolt holes is facing the ship’s  
bow.  
a=b  
a
Bow  
b
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
1.3.4 Assembling and mounting of hull unit  
The hull unit is shipped as the parts shown in the hull unit kit on Equipment Lists (page iv and  
after). Assemble the hull unit as shown in the procedure below.  
Necessary tools  
Name  
Specification  
Remarks  
Recommended: double offset  
wrench  
Wrench  
Wrench  
For M10 (Hex. size 17 mm)  
For M20 (Hex. size 20 mm)  
55 mm  
Pipe Wrench  
Ball Wrench  
For fixing gland  
Hex size 4 mm  
For fixing the dome  
1. Calculate necessary length of main shaft from the length of retraction tank Lt and cut off the  
spare portion. When 1 m or 1.8 m long tank is used, main shaft (1.17 m or 1.97 m) can be  
used without cutting off any portion.  
Supplied length: 2.2 m or 3.8 m  
Lt + 200 mm for 400 mm stroke  
Lt + 50 mm for 250 mm stroke  
Take care  
not to damage.  
2. Remove hex bolt, nut, spring washers, flat washers and trunnion pins from the main body  
flange. And then, mount the raise/lower drive unit on the shaft sleeve by using the hardware  
removed.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
G
IN  
N
R
A
W
WARNING  
Raise/lower  
section  
Flat  
washer  
Nut  
Hex. bolt  
(M10X30)  
Shaft sleeve  
Spring washer  
Flat washer  
Trunnion pin  
Shaft sleeve and raise/lower drive unit assembly  
3. Pass the transducer cable through the main shaft.  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. Fully screw main shaft into the soundome neck, and then unscrew by four turns. Coat  
threads with adhesive (HIGH SUPER).  
Main Shaft  
Grasp the soundome nec  
k with a wrench,  
and tighten the shaft with a pipe wrench.  
Coat threads with adhesive  
(HIGH SUPER).  
Applying Adhesive (HIGH SUPER) to main shaft  
5. Screw in main shaft completely.  
6. As shown in the drawing below, confirm that the narrowest gap between the tank guide, and  
retraction tank in the range (20 to 170 mm) is within 0.5 mm.  
Slide range  
(Stroke) 250 or 400  
Retraction tank  
20 mm (400 stroke) -  
170 mm (250 stroke)  
Tank guide  
less than 0.5mm  
Tank and tank guide, sectional view  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7. If the gap at a side is more than 0.5 mm, install a shim to make the gap within 0.5 mm.  
a) Unscrew four M10x50 bolts.  
b) Unscrew four countersunk screws, then attach the shim with the countersunk screws as  
shown below.  
Nut  
Flat washer  
Countersunk screw  
(M4x16)  
Hex. bolt  
(M10x70)  
Guide plate  
Shim (1.0)  
Flat washer  
Shim (1.5)  
Spring washer  
Hex. bolt  
(M10X50)  
Installing shims  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
The table below shows tank length and necessary shim thickness. In addition, the shim  
thickness shown is for one side. For example, when cutting the 1800 mm tank to 800 mm, the  
tank inside diameter is 191.25 mm, shim thickness is 2.5 mm as shown the table in below.  
8
7
6
5
4
3
2
1
0
1800  
1600  
1400  
1200  
1000  
800  
600  
400  
200  
0
189  
190  
191  
192  
193  
194  
Tank inside dia. Φ B (mm)  
For 1 m tank  
For 1.8 m tank  
Shim thickness  
The table below shows number of shims required and shim thickness.  
Shim thickness  
0
0.5  
1
1
1.5  
2
1
2.5  
1
3
1
1
3.5  
1
4
2
4.5  
5
2
1
5.5  
6
2
2
6.5  
2
t2.0  
t1.0  
t0.5  
2
2
1
1
1
1
1
2
1
1
1
1
1
Inside dia of tank 188.1 188.7 189.3 189.9 190.5 191.1 191.7 192.3 192.9 193.5 194.1 194.7 195.3 195.9  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
8. Apply THREE BOND 1104 to the inside of tank guide. And then, fasten tank guide at the  
neck* of the main shaft securely with M10X80 bolts.  
Hex. Bolt  
(M10X80)  
: coated with THREE BOND 1104  
Flat washer  
Spring Washer  
Nut  
*
Bow Mark  
Bow  
Face the tank guide  
toward ship's bow.  
Tank guide attachment  
9. Pass the main shaft through shaft sleeve.  
10. Pass the main shaft through the shaft retainer at the raise/lower drive unit.  
Pipe cap  
U-nut  
Shaft retainer  
Spring washer  
Hex. bolt M10X35  
Bow mark  
Main body flange  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
the main shaft with and shaft retainer.  
12. Fix the jubilee clip to the main shaft.  
Hex. bolt  
Shaft retainer  
15 mm  
1-2 mm  
Jubilee Clip  
Main shaft  
Note: Attach the shaft retainer so it is 15 mm from the top of the shaft. The soundome is then  
placed 10 mm above the bottom of tank when retracted.  
13. Insert grease cotton (supplied with shaft sleeve), and fix them with the cotton retainer as  
follows.  
a) Wind grease cotton onto main shaft.  
b) Mark on the cotton as below.  
c) Remove the cotton from the shaft, and then cut it at the position of the mark. Discard the ends.  
d) Wind cottons as shown below.  
e) Push cottons into the main body flange.  
f) Tighten the grease cotton retainer.  
Space joints of grease cotton  
120 apart and push them into  
body flange.  
Wind grease cotton  
onto main shaft and  
cut it as shown below.  
Spring washer  
Cotton retainer  
Installing grease cotton on the main shaft  
14. Fasten the pipe cap (supplied) to main shaft.  
15. Unscrew eight pcs of M5x30 socket head cap screws with soundome fixing tool to separate  
soundome.  
Note: Do not unfasten two nuts painted in red.  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
NOTE  
Do not unfasten two nuts  
painted in red.  
Socket head cap screw  
8 pcs, M5x30  
Unfastening the nuts may allow  
water to leak inside, which can  
damage the soundome.  
Spring washer  
Rotate 4 or 5 turns by hand to make  
sure that turning mechanisms are  
functioning properly.  
O-ring  
Remove.  
Apply KINORUSTER.  
Trusshead screws (6 pcs.)  
Protection sponge  
Do not unfasten these trusshead  
screws. Oil may leak inside.  
Soundome  
Detaching the soundome  
16. Throw away protection sponge placed in soundome.  
17. Stand the soundome upright on top of the soundome packing. Fill the soundome with oil  
(supplied) so the level is 5 cm on the top of the soudome. Keep the soundome packing for  
future use.  
Ball wrench  
Sonar oil  
5 cm  
Stand the soundome upright  
on top the soundome packing.  
Filling the soundome with sonar oil  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CAUTION  
Keep oil away from eyes. Where protective  
goggles when working with the oil. The oil  
cause inflammation of the eyes.  
Do not touch the oil. The oil can cause  
inflammation of the skin. Wear protective  
gloves when working with the oil.  
Do not ingest the oil. Diarrhea or vomiting  
can result.  
Keep the oil out of reach of children.  
EMERGENCY  
If the oil enters the eyes, flush with clean  
water about 15 minutes. Consult a  
physician. If oil contacts skin, wash with  
soap and water. If the oil is ingested, see a  
physician immediately.  
DISPOSAL OF OIL AND ITS CONTAINER  
Dispose of oil and its container in  
accordance with local regulations.  
For further information,contact place of  
purchase.  
STORAGE  
Seal container to keep out foreign material.  
Store in dark place.  
18. Rotate the transducer manually as shown angle in below, and then refit soudome.  
Transducer  
Soundome  
.
Note 1: Do not lay the oil-filled soundome for five minutes. Oil may leak.  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
When the soundome is painted to keep marine life off the transducer, observe the following  
precautions:  
Use only anti-fouling paint type MARINE STAR 20 (Manufacture: Chugoku Marine Paint Co.,  
Ltd., Japan).  
Paint only the plastic portion of the dome. Painting the metal parts causes corrosion.  
Paint area  
19. Clean surface of gasket, tank flange and shaft sleeve, and then apply THREE BOND 1104  
to flange gasket.  
20. Apply a slight coat of KINORUSTER to bolts, nuts and washers.  
21. Set the hull unit into the retraction tank, taking care not to damage soundome.  
U-nut  
Shaft retainer  
Spring washer  
Hex. bolt M10X35  
Nut  
Spring washer  
Flat washer  
Bow mark  
Shaft sleeve  
Flange gasket  
Retraction tank  
flange  
Flat washer  
Hex. bolt M20X80  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
22. Fix the shaft sleeve and retraction tank with hex bolts, flat washers and spring washers.  
Hex bolt  
Shaft retainer  
15 mm  
1-2 mm  
Jubilee clip  
Main shaft  
Bow  
10 mm  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Checking manual raise/lower of soundome with hand crank  
Perform this check after all wiring has been completed.  
CAUTION  
Turn the main power off before this check,  
otherwise the raise/lower motor action may  
cause injurely.  
1. Turn off the breaker on the hull unit.  
2. Detach the gear cover.  
3. Set wrench (opposite side19 mm) to the screw shaft gear.  
4. The transducer should rise/lower smoothly with even force in upper to lower limits. If not,  
the centers of the shaft sleeve and the retraction tank are not aligned. Adjust the hull  
mounting position if necessary. Check the following points.  
Painting inside tank not smooth  
Inner diameter of tank not uniform  
Welding bead  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1.4  
Interface Unit  
For the blackbox type, the interface unit is shipped as standard.  
1.4.1 General mounting considerations  
The mounting location should be well ventilated and dry, avoiding splay or rain.  
The unit can be mounted on a bulkhead or the deck.  
Secure the maintenance space shown in drawing below for ease of maintenance and  
service.  
The maximum cable length between the interface unit and the transceiver unit is 10 m.  
External  
monitor  
06S4078  
A
06S4078  
B
Transceiver  
unit  
Monitor unit  
MU-100C  
Interface  
unit  
<
A+B 15m  
=
External  
monitor  
External  
monitor  
06S4078  
C
06S4078  
A
Transceiver  
unit  
Interface  
unit  
Interface  
unit  
<
A+C 15m  
=
1.4.2 Mounting method  
Fasten the interface unit with four tapping screws (5X20, local supplied).  
For bulkhead mounting, tighten upper tapping screws so there is 5 mm clearance between  
bottom of screw head and bulkhead, and screw slots of the unit. Then fasten lower screws.  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1.5 Motion Sensor MS-100 (option)  
The MS-100 measures ship’s pitching and rolling angles with sensor using the principles of the  
gyroscope. The MS-100 is free from error caused by ship’s vertical and horizontal motion.  
Therefore, it can be installed at any convenient location. However, ship’s semi-permanent  
inclination due to loading imbalance cannot be detected. Compensate for this as described in  
Chapter 3.  
1.5.1 Mounting considerations  
Vibration in the mounting area should be minimal.  
Locate the unit away from areas subject to water splash.  
The ambient temperature should not exceed 50 °C  
1.5.2 Mounting procedure  
Orient the FORE mark on the unit toward the ship’s bow and mount the unit level to within 5° in  
all direction. For the offset, see Chapter 3.  
FORE  
θ ≤ 5°  
AFT  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2. Wiring  
2.1  
Wiring among Units  
The figure on the next page shows wiring among units.  
The signal cables are fitted with connectors. Connect the cables to the display, transceiver  
and hull units referring to the interconnection diagram and the drawing on page S-1.  
The power cable should be arranged locally. Use power cable type DPYCYS-2.5 (Japan  
Industrial Standard cable) or equivalent cables. Attach climp on lugs as shown below.  
40  
5
FV2-4(blue)  
50  
Vinyl sheath  
Armor  
Braided shield  
Conductor  
Insulator  
Inclusion  
Tape  
Braided shield  
Sheath  
Armor  
Vinyl sheath  
S = 2.5 mm2  
=15.2 mm  
The raise/lower drive motor and breaker are different depending on ship’s mains.  
Install the main switch for the sonar where it can be easily accessed. Turn off this switch  
when the sonar is not being used, to reduce power consumption and to prevent the  
transducer from slipping by vibration.  
If D-sub connector is too large to pass through the hole on the monitor, transducer and/or  
interface unit, remove the connector cover.  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Navigation Equipment  
Note1  
Remote  
Controler  
(5m)  
*a  
*b  
06S4078  
(5/10m)  
Interface  
Unit  
MONITOR  
Note 2  
12-32VDC  
HULL UNT  
DATA/VIDEO OUT  
SPEAKER  
MOTION SENSOR  
250V-DPYCYS-2.5  
06S4037  
Speaker  
(
10m)  
(w/cable)  
12-32VDC  
Motion Sensor  
Ext. KP  
06S4081  
(
3.5/5.2m)  
06S4080(15/30/50m)  
12/24-32VDC  
250V-DPYCYS-2.5  
Note1:  
Cable between the monitor unit and control unit  
06S4079 (0.15m standard, for uni body type)  
06S4085 (1.5m option, for separate type)  
64S4063 (5m option, for separate type)  
Note2:  
A VGA monitor (local supply) can be added by  
the connecting the optional interface unit.  
Note3:  
<
*: a+b 15m  
=
Wiring, with monitor  
24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Interface unit  
Note 1  
Navigation Eauipment  
15m  
*b  
External monitor  
Interface unit  
Note 2  
*a  
External monitor  
06S4078  
(5/10m)  
CONT  
REM  
64S4063(5m)  
06S4078  
(5/10m)  
Control unit, back view  
(5m)  
Remote  
Controler  
12-32VDC  
HULL UNT  
SPEAKER  
DATA/VIDEO OUT  
MOTION SENSOR  
Transceiver unit  
DPYCYS-2.5  
06S4037  
Speaker  
(w/cable)  
(
10m)  
Ext. KP  
12-32VDC  
06S4081  
Motion senser  
(3.5/5.2m)  
06S4080(15/30/50m)  
12/24-32VDC  
DPYCYS-2.5  
Hull unit  
Note1: Two interface units are connectable.  
Note2: For blackbox type, the display monitor (local  
supply) is reqired.  
<
Note3: *a+b 15m  
=
Wiring, no monitor  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.2  
Transceiver Unit  
Connect the cables as figure in below. Remove the cover of the power terminal board.  
06P0240  
J3  
NH6P  
CR12  
J6  
J1  
+ -  
J2  
TB1  
*Note  
*Note  
DATA/VIDEO OUT  
SPEAKER  
External speaker  
SC-05WR  
Earth  
MOTION SENSOR  
12-32VDC  
Monitor unit  
MU-100C  
or  
Interface unit  
IF-8000  
TRX  
To ship's  
earth  
Motion  
sensor  
MS-100  
DPYCYS-2.5  
Ship's mains  
12/24/32 DCV  
06S4080  
Hull unit  
External KP  
CH-254/CH-255  
*Note: Fix the braided shield with the clamp.  
Transceiver unit, internal view  
26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.2.1 Synchronizing Transmission with Echo Sounder or Other  
Sonar  
To synchronize transmission of the CH-250 with an echo sounder or other type of sonar,  
connect it as shown below.  
NH6P (local supply)  
Transceiver unit  
Sonar, E/S  
Vinyl wire (local supply)  
AWG22-26  
J3  
06P0240  
3 to 15V  
possitive  
KP OUT  
+5V to 15V  
GND  
3
KPI  
EXT_SW 5  
6
GND  
TRX clamp  
Connection of transceiver unit to other sonar  
Menu setting  
1. Press the [MENU] key to display the user menu.  
2. Operate the cursor pad to select COM1 at the top of menu display.  
MENU  
COM1 COM2 HORZ VERT ES PRESET SYS  
TX POWER  
PULSELENGTH  
TX RATE  
MAX  
LONG  
10  
INT REJECT  
AGC  
OFF  
OFF  
0
AUDIO LEVEL  
REPLACE ONE OF ANY COLORS AMONG COLOR BAR WITH WHITE.(OFF)  
: SELECT  
: CHANGE  
MENU: END  
User menu (COMN)  
3. Press the [] to select TX RATE.  
4. Press the [] to display the setting window.  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TX RATE  
5
EXT. MIN  
MAX  
(EXT., 1-10)  
TX rate setting window  
5. Press the ["] to select EXTERNAL.  
6. Press the [MENU] key to close the user menu.  
Note: Outputting KP of CH-250 to other sonar, echo sounder  
Transceiver unit  
J3  
06P0240  
2
KPO  
(E/S transmits, SONAR)  
12V  
positive  
GND 6  
CH-250 accepts positive KP with  
amplitude of 0V to 12V.  
Outputting KP of CH-250 to other sonar, echo sounder  
g)  
28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.3  
Hull Unit  
Pass the cables to 06P0426 Board through the cable protectors.  
Fasten glands securely  
by hands.  
J2  
06P0246  
Cable from transducer  
06S4081  
J1  
J3  
*Note  
J2  
J1  
Cable from transceiver unit  
06S4080  
*Note  
*Note  
TB2  
+
Power cable  
250V-DPYCYS-2.5  
-
Power Switch  
Should always be in up (ON).  
06P0243  
Earth  
Connect to ship's earth.  
*Note: Fix the braided shield with cable clamp.  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.4  
Interface Unit  
CONT  
NMEA  
DATA/VIDEO IN DATA/VIDEO OUT  
RGB OUT  
VGA  
monitor  
Transceiver unit cable  
06S4078  
NAV  
Earth  
Connect to ship's earth.  
Control  
unit  
Monitor unit  
cable  
cable  
06S4078  
06S4079  
The blackbox type is required to connect a standard VGA monitor via the interface unit IF-8000.  
Supply monitor and interconnection cable (Max. length 15 m with Dsub-15P connectors of male,  
three rows of 15 pins) locally. The monitor used should satisfy the specifications shown below.  
VGA type  
ANALOG RGB 0.7 Vpp, positive polarity  
TLL level H, V, Negative polarity  
Note: Cut and remove the rubber covers as below to attach connectors to the interface unit..  
Remove the  
fixing metals.  
Cut and remove  
the covers.  
Note: Connect control unit or navigator equipment to either interface unit or monitor unit  
(supplied by FURUNO).  
30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. ADJUSTMENTS  
3.1  
General Checks  
Table 3-1 General checks  
Check point, Rating  
On-keel Installation  
Check Item  
Retraction tank level  
Off-keel Installation  
Within 1 m  
Clearance between transducer and  
bottom of retraction tank when  
transducer is completely retracted  
by hand crank  
1 cm  
Transducer travel  
(lowered by hand clank)  
400 stroke:  
Minimum 30 cm  
Note: When checking, a clearance  
of approximately 1 meter is required  
under the bottom of the transducer.  
250 stroke:  
Minimum 22 cm  
Bow mark on the shaft sleeve should face  
ship's bow.  
Transducer heading  
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table 3-1 general checks (con’t)  
Check point, Rating  
Check Item  
Wiring check  
All cables are correctly connected.  
All lead wires are tightly fixed with contact  
pins or crimp-on lugs.  
All screws are firmly fastened.  
Cables are firmly secured.  
Cables shields are properly grounded.  
Noise generating machinery (motor,  
radiotelephone, TV set, etc.) are not placed  
nearby.  
Rejecting source of noise and  
interference  
Magnetic devices are not placed in the  
vicinity of display unit.  
Earth  
Each unit is grounded with a copper strap.  
Ship’s mains voltage  
Ship’s mains voltage is stable 12, 24 or 32  
VDC.  
Watertightness  
Water should not leak from the main body  
flange or along the main shaft.  
3.2  
TX Frequency Checking  
Check the TX frequency after the installation.  
1. Press the [MENU] key to open the user menu.  
2. Press the cursor pad to select SYS at the top of the menu display.  
MENU  
COM1 COM2 HORZ VERT ES SHORT-CUT  
SYS  
GO TO SYS MENU  
YES  
NO  
: SELECT  
MENU: END  
: CHANGE  
User menu (SYS)  
3. Press the [] to select GO TO SYS MENU.  
4. Press the [] to select YES to display the system menu.  
32  
Download from Www.Somanuals.com. All Manuals Search And Download.  
** SYSTEM MENU **  
SYSTEM SETTING:  
RANGE-SONAR MODE  
RANGE-VERTICAL MODE  
RANGE-E/S MODE  
RANGE-TRACK MODE  
COLOR PALETTE  
LANGUAGE  
SYSTEM BACKUP  
LOAD BACKUP DATA  
HEADING OFFSET, DRAFT OFFSET  
ADJ MOTION SENSOR  
TX FREQ ADJUST  
TEST  
TEST PATTERN  
DEMO MODE  
DEFAULT  
: MENU DISPLAY MENU: END  
: SELECT  
System menu  
5. Press the [] to select TEST.  
6. Press the [] to show the test display.  
MAIN PROGRAM NO. 0650110-**.**  
PANEL PROGRAM NO. 0650104-0**  
ROM  
: OK  
: OK  
: OK  
: OK  
: OK  
: 180 kHz  
: 10  
RAM  
VRAM  
NMEA  
PANEL CPU  
TX FREQUENCY  
ROLL  
PITCH  
: 10  
PULSES  
359  
NG  
TRAIN  
0
TEST COUNT= : 0  
REMOTE CONTROL  
PANEL  
0
0
0
0
0
0
0
0
0
0
0
0
1
0
0
0
0
(LED)  
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
EXIT  
0
0
0
0
** Program Version No.  
Test display  
7. Check the frequency at the TX FREQUENCY line on the test display.  
8. Press the [MENU] key several times to close the menu.  
33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3.3  
Heading Alignment/Soundome Setting  
Heading alignment  
The heading line can be compensated through the system menu ( –30° to +30°).  
1. Locate a target (buoy, etc.) in the bow direction and display it on the screen at close range,  
read deviation. The heading alignment is correct when the target is displayed at 12 o’clock  
on the screen.  
Heading  
12 o'clock position  
Buoy  
When on-screen target is skewed right,  
transducer heading is skewed left.  
Checking heading alignment  
2. Press the [MENU] key to display the user menu.  
3. Press the cursor pad to select SYS at the top of menu display.  
MENU  
COM1 COM2 HORZ VERT ES SHORT-CUT  
SYS  
GO TO SYS MENU  
YES  
NO  
: SELECT  
MENU: END  
: CHANGE  
User menu (SYS)  
4. Press the [] to select GO TO SYS.  
5. Press the [] to select YES to display the system menu.  
34  
Download from Www.Somanuals.com. All Manuals Search And Download.  
** SYSTEM MENU **  
SYSTEM SETTING:  
RANGE-SONAR MODE  
RANGE-VERTICAL MODE  
RANGE-E/S MODE  
RANGE-TRACK MODE  
COLOR PALETTE  
LANGUAGE  
SYSTEM BACKUP  
LOAD BACKUP DATA  
HEADING OFFSET, DRAFT OFFSET  
ADJ MOTION SENSOR  
TX FREQ ADJUST  
TEST  
TEST PATTERN  
DEMO MODE  
DEFAULT  
: MENU DISPLAY MENU: END  
: SELECT  
System menu  
6. Press the [] to select HEADING OFFSET, DRAFT OFFSET, and then press the [] to  
display the heading offset display.  
** HEADING OFFSET/DRAFT OFFSET **  
HEADING  
DRAFT  
:
:
0 ˚  
(-180˚ - +180˚)  
(0.0 - 60.0m)  
0.0 ˚  
: CHANGE  
MENU: END  
: SELECT  
Head offset display  
7. Press the [] [] to align heading (1 step) so that the target on heading direction appears  
at the twelve o’clock position.  
8. Press the [] to choose draft.  
9. Press the [] [] to set ship’s draft.  
10. Press the [MENU] key several times to close the menu.  
11. Confirm that the target on heading direction appears at the twelve o’clock position.  
Soundome setting Confirmation  
Set the serial number for the soundome connected, under nine-999 or over 1000.  
1. Open the SYSTEM MENU following step 1 to 4 in the above.  
2. Select SYSTEM SETTING, and then press the [] to open the SYSTEM SETTING 1 menu.  
35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
** SYSTEM SETTING 1 **  
MENU  
1
2
POSITION  
TRACK  
: SHIP'S L/L SHIP'S LOP CURSOR L/L  
: OFF  
ON  
CURRENT DATA  
: OFF  
FLOW FROM  
FLOW TO  
HEADING INDICATION : TRUE  
AZ  
NORTH MARK  
CSE DATA  
: OFF  
: NAV  
: GPS  
: OFF  
: m  
ON  
GYRO  
NAV DATA  
LoranC LoranA DR DECCA OTHERS  
TVG CORRECTION  
UNIT  
1/2  
ft  
1/1  
fa  
HIRO P/B  
TEMP  
:
C
F
TARGET L/L  
CUSTOM KEY  
EMPHASIS MODE  
ETA MARK  
: OFF  
ON  
:
PRESET KEY SHORT-CUT KEY  
: OFF  
: OFF  
NORMAL  
RED  
10sec 30sec 1min 3min  
6min  
: CHANGE  
MENU: END  
: SELECT  
System setting 1 menu  
3. Press the cursor pad to select 2 and press the [] to show SYSTEM SETTING 2 menu.  
** SYSTEM SETTING 2 **  
1
2
MENU  
:
STABILIZER  
: OFF  
: OFF  
ON  
AUTO RETRACTION  
(OFF, 5-15 kt)  
SPEED ALARM/MESSAGE : OFF  
ON  
DOT  
LINE  
SWEEP INDICATOR  
:
SOUNDOME SER. NO.  
: ~999  
: NO  
1000~  
YES  
DEFAULT SETTING  
MAXIMUM ALLOWABLE SPEED IS 15 KNOTS WHILE SOUNDOME IS BEING  
RETRACTED. IF VESSEL HAS REPAID ACCELERATION CAPABILITIES,  
AUTO RETRACTION SETTINGS OF 10-12 KNOTS ARE MANDATORY TO  
AVOID CATASTROPHIC DAMAGE TO SOUNDOME ASSY. ANY PHISICAL  
DAMAGE TO THE SOUDOME ASSY. IS CONSIDERED ABUSE AND  
IS NOT A WARRANTY ISSUE.  
: CHANGE  
MENU: END  
: SELECT  
System setting 2 menu  
4. Confirm the soundome serial number at SOUNDOME SER. NO. If change, press [] to  
select SOUNDOME SER. NO. and then press the [] to select ~999 or 1000~  
appropriately.  
5. Press the [MENU] key several times to close the menu.  
36  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3.4  
Adjustment of Motion Sensor  
When the ship has a semi-permanent inclination, offset it as follows.  
1. Press the [MENU] key to display the user menu.  
2. Press the cursor pad to select SYS at the top of the menu display.  
MENU  
COM1 COM2 HORZ VERT ES SHORT-CUT  
SYS  
GO TO SYS MENU  
YES  
NO  
: SELECT  
MENU: END  
: CHANGE  
Display to select the system menu  
3. Press the [] to select GO TO SYS.  
4. Press the [] to select YES.  
** SYSTEM MENU **  
SYSTEM SETTING:  
RANGE-SONAR MODE  
RANGE-VERTICAL MODE  
RANGE-E/S MODE  
RANGE-TRACK MODE  
COLOR PALETTE  
LANGUAGE  
SYSTEM BACKUP  
LOAD BACKUP DATA  
HEADING OFFSET, DRAFT OFFSET  
ADJ MOTION SENSOR  
TX FREQ ADJUST  
TEST  
TEST PATTERN  
DEMO MODE  
DEFAULT  
: MENU DISPLAY MENU: END  
: SELECT  
System menu  
5. Press the [] to select ADJ MOTION SENSOR, and then press the [] to display ADJ  
MOTION SENSOR menu.  
** ADJ MOTION SENSOR **  
ROLL ANGLE: 0˚  
PITCH ANGLE: 0˚  
ADJ: +5  
ADJ: +5  
˚
˚
(-10˚ - +10˚)  
(-10˚ - +10˚)  
: SELECT  
: CHANGE  
MENU: END  
Adj motion sensor menu  
37  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6. Press [] [] to select ROLL ANGLE or PITCH ANGLE.  
7. Press [] [] to adjust (-10° to +10°).  
By using a clinometer or other means, measure ship’s semi-permanent inclination angle. Take  
the polarity of the angle as follows. For example, if the stern is 3° down, set -3°.  
+
+
0
0
+
-
ROLL ANGLE Starboard up  
PITCH ANGLE Stern up  
Starboard down  
Stern down  
8. Press the [MENU] key several times to close the menu.  
3.5 System Back Up  
After setting the equipment follow the procedure below to back up system settings. Backup data  
can be loaded in the event of equipment trouble, to restore previous system settings.  
1. Press the [MENU] key to display the user menu.  
2. Press the cursor pad to select SYS at the top of the menu.  
MENU  
COM1 COM2 HORZ VERT ES SHORT-CUT  
SYS  
GO TO SYS MENU  
YES  
NO  
: SELECT  
MENU: END  
: CHANGE  
Display to select the system menu  
3. Press [] to select GO TO SYS MENU.  
4. Press [] to select YES.  
The system menu appears.  
38  
Download from Www.Somanuals.com. All Manuals Search And Download.  
** SYSTEM MENU **  
SYSTEM SETTING:  
RANGE-SONAR MODE  
RANGE-VERTICAL MODE  
RANGE-E/S MODE  
RANGE-TRACK MODE  
COLOR PALETTE  
LANGUAGE  
SYSTEM BACKUP  
LOAD BACKUP DATA  
HEADING OFFSET, DRAFT OFFSET  
ADJ MOTION SENSOR  
TX FREQ ADJUST  
TEST  
TEST PATTERN  
DEMO MODE  
DEFAULT  
: MENU DISPLAY MENU: END  
: SELECT  
System menu  
5. Press [] to select SYSTEM BACKUP.  
6. Press [] to display the system backup menu.  
** SYSTEM BACK UP**  
NO YES  
ARE YOU SURE?  
:
NOTE: OVERWITES PREVIOUS BACKUP DATA  
MENU: END  
: CHANGE  
System backup menu  
7. Press [] to select YES.  
8. Press the [MENU] key.  
The backup data is loaded, and then return to the system menu.  
9. Press the [MENU] key to return to the normal display.  
39  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3.6  
Setting of Interface Unit  
Set DIP switch S1 in the interface unit as follows.  
The monitor unit MU-100C or the interface unit is connected to DATA/VIDEO OUT port of  
the interface unit : all OFF.  
Nothing is connected to DATA/VIDEO OUT port of the interface unit : all ON.  
ON  
J1  
J3  
J2  
*: J6 and J7 set to "THROUGH" side.  
Interface unit, DIP switch S1 location  
External  
Monitor  
Processor  
Unit  
Interface  
Unit  
Monitor  
Unit  
S1:All OFF  
External  
Monitor  
Processor  
Unit  
Interface  
Unit  
S1:All ON  
External  
Monitor  
External  
Monitor  
Processor  
Unit  
Interface  
Unit  
Interface  
Unit  
S1:All ON  
S1:All OFF  
40  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Input/Output Description  
The CH-250 can receive/transmit the following sentences in NMEA 0183 format.  
Input  
GLL:  
VTG:  
DBT:  
DBS:  
DPT:  
GGA:  
VDR:  
RMA:  
RMC:  
VHW:  
HDG:  
MTW:  
HDM:  
HDA:  
HDT:  
GPS position  
Ground speed/true course  
Depth (Ignore talker, NMEA Ver1.5)  
Depth (Ignore talker)  
Depth (Ignore talker, NMEA Ver2.0)  
GPS position/Speed/Course (Ignore talker)  
Current direction/current speed (Ignore talker)  
Loran C position/LOP/Speed/Course  
GPS position/Speed/Course  
Water speed/Heading  
Heading  
Temperature  
Heading  
Temperature (Ignore talker)  
Heading  
Output  
TLL:  
When entering event mark.  
Priority (Input)  
LOP can be displayed only when RMA is inputted.  
Own ship’s position GGA>RMC>RMA>GLL  
Course  
Heading  
Speed  
Depth  
Temperature  
Current  
RMC>RMA>VTG  
HDG>VHW>HDM  
RMC>RMA>VTG>VHW  
DPT>DBT>DBS  
MTW>MDA  
VDR  
41  
Download from Www.Somanuals.com. All Manuals Search And Download.  
This page is intentionally left blank.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
D-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
D-2A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
D-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
D -8  
T akahashi T .  
T akahashi T .  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
D-11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
D-13  
Y. Hatai  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
S-1  
1
2
3
4
5
6
上下装置  
HULL UNIT  
送受信装置 TRANSCEIVER UNIT  
CH-253  
表示部ユニット  
DISPLAY UNIT  
MU-100C  
操作部 CONTROL UNIT  
CH-252  
上下動部  
RAISE/LOWER DRIVE UNIT  
CH-2541/S  
CH-2551/S  
A
B
C
D
CONT  
MJ-A10  
SPFD  
DISP  
MJ-A10  
SPFD  
CH-254/S 400mmストローク  
400mm TRAVEL  
CH-255/S 250mmストローク  
250mm TRAVEL  
4B2 PRA 06P0246  
3B1 CPU 06P0240  
1B1 DISP 06P0238  
2B1 PNL 06P0239  
J1  
DATA/VIDEO OUT  
XM2A-2501  
DATA/VIDEO IN  
XM2A-2501  
*3  
VHR-3N  
CN5  
CN2  
VHR-4N  
1
2
3
4
XH-20  
CN4  
CN1  
CN2  
CN1  
J3  
J2  
TD1  
TD2  
J1  
TR1  
J1  
J1  
J2  
R
MJ-A10SPF0002,φ9  
06S4079 0.15m  
06S4085 1.5m  
64S4063 5m  
1
2
3
1
2
3
4
5
6
7
8
9
PWRON-H  
PWRON-C  
RLCONT-H  
RLCONT-C  
TRM1-H  
TRM1-C  
TRM2-H  
TRM2-C  
TIM1-H  
R
1
2
3
4
5
6
7
8
9
1
2
3
4
5
6
7
8
9
TRXTD-A  
TRXTD-B  
CONTD-A  
CONTD-B  
PSW-H  
1
2
3
4
5
6
7
8
9
1
2
3
4
5
6
7
8
9
TRXTD-A  
TRXTD-B  
CONTD-A  
CONTD-B  
PSW-H  
PSW-C  
+12V  
GND  
SCAN-REV  
TR2  
TD GND  
NC  
G
B
G
B
TD GND  
HS-N  
VS-N  
YC-N  
HS-N  
VS-N  
YC-N  
TRXTD-A  
CONTD-A  
TD-A  
旋回俯仰部 SOUNDOME  
CH-2542/S  
PSW-C  
+12V  
CN3  
XHP-3  
J3  
HULL UNIT  
1
2
3
SIGP+  
SIGP-  
NC  
TRXTD-A  
CONTD-A  
TD-A  
GND  
SCAN-REV  
TRX  
*3  
*3  
06S4078,φ12  
5/10m  
5B1 DOM 06P0244  
06S4080,φ13.7  
15/30/50m  
10 TIM1-C  
11  
RD-A 10  
11  
10 RD-A  
11  
PSW-H  
12 12VA  
13 12VA-GND  
14 R-GND  
F.GND 10  
10 F.GND  
VHR-3N  
1
2
3
J2  
TD1  
TD2  
TIM2-H  
PSW-H  
12 TIM2-C  
13 HULLV-H  
14 UPLMT-H  
12VA 12  
0V 13  
R-GND 14  
G-GND  
B-GND 16  
4B1 DRV 06P0243  
CN4  
SOUNDOME  
*3  
06S4081  
3.5/5.2m  
TD GND  
XHP-12  
XHP-12  
CN1  
J1  
XH-20  
J1  
J2  
1
2
3
4
5
6
7
8
9
1
1
2
3
4
5
6
7
8
9
15  
15  
15  
TIP1  
TIP3  
TIP2  
TIP4  
TRP1  
TRP3  
TRP2  
TRP4  
TR0  
TIP1  
TIP3  
TIP2  
TIP4  
TRP1  
TRP3  
TRP2  
TRP4  
TR0  
PWRON-H  
PWRON-C  
RLCONT-H  
RLCONT-C  
TRM1-H  
DNLMT-H  
G-GND  
2
3
4
5
6
7
8
9
16 TR0-H  
17 F0-H  
16 B-GND  
17 HS-N-GND  
HS-N-GND 17  
リモートコントローラ  
REMOTE CONTROLLER  
*1  
CH-256  
18  
19  
18  
19  
18  
19  
F1-H  
F2-H  
VS-N-GND  
YC-N-GND  
VS-N-GND  
YC-N-GND  
NMEA  
*3  
MJ-A6SPFD  
CN3  
J1  
TRM1-C  
TRM2-H  
TRM2-C  
TIM1-H  
20 COM_C  
TRXTD-B 20  
CONTD-B 21  
20 TRXTD-B  
21 CONTD-B  
TD-A  
TD-B  
RD-A  
RD-B  
NC  
1
2
3
4
5
6
22  
22  
TD-B  
TD-B  
XH-6  
CN7  
+12V  
KPO  
KPI  
SIG  
EXT-SW  
GND  
J3  
MJ-A6SPF0011-050C/100C  
MJ-A6SPF0012-050C/100C  
5/10m,φ6.0  
1
2
3
4
5
6
RD-B 23  
PSW-C 24  
12VA 25  
23 RD-B  
24 PSW-C  
25 12VA  
EXTERNAL  
KP/SIG  
航法装置  
NAV. EQUIPMENT  
IEC61162-1(NMEA)  
+12V 10  
GND 11  
10 +12V  
11 GND  
TIM1-C 10  
TIM2-H 11  
F.GND  
12  
12  
12  
GND  
GND  
TIM2-C  
HULLV-H 13  
UPLMT-H 14  
DNLMT-H 15  
*2  
IV-2sq.  
16  
F0-H 17  
(+)12/24-32VDC F1-H 18  
TR0-H  
3B2 TRX 06P0241  
CN5  
*2  
DPYCY-2.5  
TB2  
1
2
VHR-4N  
J1  
(-)  
19  
20  
1
F2-H  
COM_C  
TR1  
TR2  
2
3
4
TD GND  
NC  
SPEAKER  
スピーカ  
SPEAKER  
SC-05WR  
*1  
XHP-3  
CN6  
CN2  
J6  
5m  
1
2
3
SIGP+  
SIGP-  
NC  
S06-9-5 *1  
延長ケーブル 5m  
EXTENSION CABLE  
MOTION  
SENSOR  
*2  
DPYCY-2.5  
3B3 PWR 06P0242  
*1  
06S4037  
φ9,10m  
TB1  
(+)12-32VDC  
(-)  
動揺検出器  
*1  
MOTION SENSOR  
MS-100  
CN-3  
J1  
12VB  
ROLL  
PITCH  
GND  
SRC-5P *3  
1
2
12/24-32 VDC  
1
2
3
4
5
*2  
DPYCY-1.5  
100/110/115/  
200/220/230VAC  
1φ, 50/60 Hz  
または OR  
傾斜角検出器  
GND  
CLINOMETER  
BS-704  
*1  
1
2
5
(+)(-)  
6
整流器  
RECTIFIER  
RU-1746B-2  
*2  
IV-2sq.  
*2  
IV-8sq.  
注記  
*1)オプション支給。  
*2)現地手配。  
*3)コネクタは工場で取付済み。  
DRAWN  
Mar.6,'06  
CHECKED  
TITLE  
名 称  
NOTE  
CH-250/S  
E.MIYOSHI  
*1. OPTION  
カラーLCDサーチライトソナー  
相互結線図  
TAKAHASHI.T  
Y. Hatai  
*2. LOCAL SUPPLY  
APPROVED  
SCALE  
*3. CONNECTOR PLUG IS FITTED AT FACTORY.  
MASS  
kg  
NAME  
COLOR SEARCHLIGHT SONAR  
INTERCONNECTION DIAGRAM  
FURUNO ELECTRIC CO., LTD.  
DWG. No.  
REF. No.  
C1316-C01- D  
Download from Www.Somanuals.com. All Manuals Search And Download.  
S-2  
1
2
3
4
5
6
上下装置  
HULL UNIT  
送受信装置 TRANSCEIVER UNIT  
CH-253  
表示部  
DISPLAY UNIT  
MU-100C  
操作部 CONTROL UNIT  
CH-252  
*5  
上下動部  
RAISE/LOWER DRIVE UNIT  
CH-2541/S  
CH-2551/S  
CONT  
MJ-A10  
SPFD  
MJ-A10SPF0002,φ9  
06S4079 0.15m  
06S4085 1.5m  
64S4063 5m  
DISP  
MJ-A10  
SPFD  
CH-254/S 400mmストローク  
400mm TRAVEL  
CH-255/S 250mmストローク  
250mm TRAVEL  
4B2 PRA 06P0246  
3B1 CPU 06P0240  
CN4  
1B1 DISP 06P0238  
2B1 PNL 06P0239  
J1  
DATA/VIDEO OUT  
XM2A-2501  
DATA/VIDEO IN  
XM2A-2501  
*3  
VHR-3N  
CN5  
CN2  
VHR-4N  
1
2
3
4
XH-20  
CN1  
CN2  
CN1  
J3  
J2  
TD1  
TD2  
J1  
TR1  
J1  
J1  
J2  
R
A
B
C
D
1
2
3
1
2
3
4
5
6
7
8
9
PWRON-H  
PWRON-C  
RLCONT-H  
RLCONT-C  
TRM1-H  
TRM1-C  
TRM2-H  
TRM2-C  
TIM1-H  
R
1
2
3
4
5
6
7
8
9
1
2
3
4
5
6
7
8
9
TRXTD-A  
TRXTD-B  
CONTD-A  
CONTD-B  
PSW-H  
1
2
3
4
5
6
7
8
9
1
TRXTD-A  
TRXTD-B  
CONTD-A  
CONTD-B  
PSW-H  
PSW-C  
+12V  
GND  
SCAN-REV  
2
3
4
5
6
7
8
9
TR2  
TD GND  
NC  
G
B
G
B
TD GND  
HS-N  
VS-N  
YC-N  
HS-N  
VS-N  
YC-N  
TRXTD-A  
CONTD-A  
TD-A  
インターフェイス  
ユニット  
I/F UNIT  
旋回俯仰部 SOUNDOME  
CH-2542/S  
PSW-C  
+12V  
CN3  
XHP-3  
DATA/VIDEO  
IN  
DATA/VIDEO  
OUT  
J3  
HULL UNIT  
SIGP+  
SIGP-  
NC  
1
2
3
TRXTD-A  
CONTD-A  
TD-A  
*1  
GND  
SCAN-REV  
IF-8000  
TRX  
*3  
XM2A-2501  
XM2A-2501  
5B1 DOM 06P0244  
06S4080,φ13.7  
15/30/50m  
J1  
J2  
10 TIM1-C  
11 TIM2-H  
12 TIM2-C  
RD-A 10  
PSW-H 11  
12VA 12  
10 RD-A  
11 PSW-H  
12 12VA  
F.GND 10  
10 F.GND  
VHR-3N  
1
2
3
J2  
TD1  
TD2  
4B1 DRV 06P0243  
CN4  
SOUNDOME  
*3  
06S4081  
3.5/5.2m  
13  
13  
13  
TD GND  
HULLV-H  
0V  
12VA-GND  
14 UPLMT-H  
15 DNLMT-H  
16 TR0-H  
R-GND 14  
G-GND 15  
B-GND 16  
14 R-GND  
15 G-GND  
16 B-GND  
XHP-12  
1
2
3
4
5
6
7
XHP-12  
CN1  
J1  
XH-20  
J1  
J2  
TIP1  
TIP3  
TIP2  
TIP4  
TRP1  
TRP3  
TRP2  
TRP4  
TR0  
1
2
3
4
5
6
7
8
9
10  
TIP1  
TIP3  
TIP2  
TIP4  
TRP1  
TRP3  
TRP2  
TRP4  
TR0  
PWRON-H  
PWRON-C  
RLCONT-H  
RLCONT-C  
TRM1-H  
1
2
3
4
5
6
7
8
9
10  
17  
17  
17  
F0-H  
HS-N-GND  
HS-N-GND  
18 F1-H  
19 F2-H  
VS-N-GND 18  
YC-N-GND 19  
18 VS-N-GND  
19 YC-N-GND  
NMEA  
*3  
MJ-A6SPFD  
CN3  
J1  
リモートコントローラ  
REMOTE CONTROLLER  
CH-256  
20  
20  
20  
1
2
3
4
5
6
TRM1-C  
TRM2-H  
TRM2-C  
TIM1-H  
TIM1-C  
COM_C  
TRXTD-B  
TRXTD-B  
TD-A  
TD-B  
RD-A  
RD-B  
NC  
*1  
21 CONTD-B  
22 TD-B  
23 RD-B  
CONTD-B 21  
TD-B 22  
RD-B 23  
PSW-C  
8
9
10  
XH-6  
CN7  
+12V  
KPO  
KPI  
SIG  
EXT-SW  
GND  
J3  
MJ-A6SPF0011-050C/100C  
MJ-A6SPF0012-050C/100C  
5/10m,φ6.0  
1
2
3
4
5
6
EXTERNAL  
KP/SIG  
航法装置  
*5  
NAV. EQUIPMENT  
24  
24  
+12V  
+12V  
PSW-C  
GND 11  
GND 12  
11 GND  
12 GND  
TIM2-H 11  
TIM2-C 12  
HULLV-H 13  
12VA 25  
25 12VA  
F.GND  
IEC61162-1(NMEA)  
RGB OUT  
Dsub-15P  
*2  
IV-2sq.  
14  
UPLMT-H  
外部モニター  
EXT. VGA MONITOR  
J3  
J4  
DNLMT-H 15  
TR0-H 16  
F0-H 17  
CONT  
MJ-A10SPFD  
3B2 TRX 06P0241  
CN5  
*2  
DPYCY-2.5  
*5  
操作部  
CONTROL UNIT  
CH-252  
リモートコントローラ  
REMOTE CONTROLLER  
CH-256  
TB2  
1
2
(+)12/24-32VDC  
(-)  
18  
F1-H  
VHR-4N  
J1  
TR1  
TR2  
F2-H 19  
COM_C 20  
1
NMEA  
MJ-A6SPFD  
2
3
4
航法装置  
NAV. EQUIPMENT  
MJ-A6SPF0011-050C/100C  
MJ-A6SPF0012-050C/100C  
5/10m,φ6.0  
*5  
TD GND  
NC  
J5  
J2  
XM2A-2501  
IEC61162-1(NMEA)  
XHP-3  
CN6  
J6  
*4 *3 *1  
06S4078  
5m,φ12  
1
2
3
SIGP+  
SIGP-  
NC  
*2  
IV-2SQ.  
インターフェイス  
ユニット  
I/F UNIT  
SPEAKER  
スピーカ  
DATA/VIDEO  
IN  
CN2  
SPEAKER  
SC-05WR  
*1  
5m  
RGB OUT  
Dsub-15P  
*1  
IF-8000  
XM2A-2501  
外部モニターNo.2  
EXT. VGA MONITOR No.2  
操作部  
J1  
J3  
S06-9-5  
延長ケーブル 5m  
EXTENSION CABLE  
*1  
CONT  
MJ-A10SPFD  
リモートコントローラ  
*5  
*2  
DPYCY-2.5  
3B3 PWR 06P0242  
MOTION  
SENSOR  
SRC-5P *3  
TB1  
(+)12-32VDC  
(-)  
CONTROL UNIT  
CH-252  
REMOTE CONTROLLER  
CH-256  
J4  
J5  
1
2
12/24-32 VDC  
*1  
06S4037  
φ9,10m  
NMEA  
MJ-A6SPFD  
動揺検出器  
CN-3  
J1  
*1  
MOTION SENSOR  
MS-100  
*2  
DPYCY-1.5  
1
12VB  
ROLL  
PITCH  
GND  
航法装置  
*5  
NAV. EQUIPMENT  
IEC61162-1(NMEA)  
MJ-A6SPF0011-050C/100C  
MJ-A6SPF0012-050C/100C  
5/10m,φ6.0  
100/110/115/  
200/220/230VAC  
1φ, 50/60 Hz  
2
3
4
5
または OR  
傾斜角検出器  
1
2
5
(+)(-)  
6
GND  
*2  
IV-2sq.  
CLINOMETER  
BS-704  
*1  
整流器  
RECTIFIER  
RU-1746B-2  
注記  
*2  
IV-2sq.  
*2  
IV-8sq.  
*1)オプション支給。  
*2)現地手配。  
*3)コネクタは工場で取付済み。  
*4)送受信装置から表示部までのケーブル長の合計は15m以下であること。  
*5)操作部と航法装置は表示部かインターフェイスユニットのどちらか一方のみに接続可能。  
DRAWN  
TITLE  
名 称  
NOTE  
CH-250/S  
E.MIYOSHI  
Mar.6,'06  
*1. OPTION  
CHECKED  
APPROVED  
SCALE  
カラーLCDサーチライトソナー(I/Fユニット使用)  
相互結線図  
TAKAHASHI.T  
Y. Hatai  
*2. LOCAL SUPPLY  
*3. CONNECTOR PLUG IS FITTED AT FACTORY.  
*4. CABLE LENGTH BETWEEN TRANSCEIVER AND DISPLAY UNIT SHOULD BE 15 m OR LESS.  
*5. CONNECT CONTROL UNIT AND NAV EQUIPMENT TO EITHER DISPLAY UNIT OR INTERFACE UNIT.  
MASS  
kg  
NAME  
COLOR SEARCHLIGHT SONAR (W/ I/F UNIT)  
INTERCONNECTION DIAGRAM  
FURUNO ELECTRIC CO., LTD.  
DWG No.  
REF. No.  
C1316-C02- D  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Electro Voice Speaker System EVR 200 User Manual
Estate Refrigerator TS22CFXT User Manual
Extron electronic Switch DVI 201xi Tx User Manual
Frigidaire Refrigerator FFHS2322MM User Manual
Garland Gas Grill XG24 JIB User Manual
GE Air Conditioner AVX08 User Manual
Generac Portable Generator 004189 1 User Manual
GE Ventilation Hood JV247PWW User Manual
GE Washer Dryer WSM2700R User Manual
Globe Kitchen Utensil 3850 User Manual