Furuno Radar Detector DRS12A User Manual

Installation Manual  
RADAR SENSOR  
DRS2D/DRS4D/  
DRS4A/DRS6A/DRS12A/DRS25A  
SAFETY INSTRUCTIONS ............................................................................i  
SYSTEM CONFIGURATION .......................................................................ii  
EQUIPMENT LISTS....................................................................................iv  
1. MOUNTING............................................................................................1  
1.1 Mounting Considerations..............................................................................................1  
1.2 Mounting Procedure for DRS2D/4D .............................................................................2  
1.3 Mounting Procedure for DRS4A/6A/12A/25A...............................................................3  
1.4 Mounting of Power Supply Unit PSU-013 (for DRS25A)/PSU-012 (Option) ................8  
2. WIRING..................................................................................................9  
2.1 Wiring inside DRS2D/4D ............................................................................................12  
2.2 Wiring inside DRS4A/6A/12A/25A..............................................................................16  
2.3 Wiring inside Power Supply Unit PSU-013 (for DRS25A) ..........................................20  
2.4 Wiring inside Power Supply Unit PSU-012 (Option)...................................................21  
PACKING LISTS...................................................................................... A-1  
OUTLINE DRAWINGS............................................................................. D-1  
INTERCONNECTION DIAGRAMS.......................................................... S-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SYSTEM CONFIGURATION  
DRS2D/4D/4A/6A/12A  
RADAR SENSOR  
DRS2D/DRS4D  
RADAR SENSOR  
DRS4A/DRS6A/DRS12A  
NMEA 2000  
Equipment  
NMEA 2000  
Equipment  
Power Supply Unit  
PSU-012*  
12-24 VDC  
OR  
Multi Function Display BlackBox  
MFDBB  
Multi Function Display  
MFD8/12  
: Standard Supply  
: Optional Supply  
: Local Supply  
RECTIFIER  
RU-1746B  
12-24 VDC  
100/110/220/230 VAC  
*The power supply unit PSU-012 is necessary in the combination of radar sensor and MFD.  
DRS2D/4D  
NO  
DRS4A  
YES  
NO  
DRS6A  
YES  
NO  
DRS12A (future development)  
MFD8  
YES  
YES  
NO  
NO  
MFD12  
MFDBB  
NO  
NO  
NO  
ii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DRS25A  
RADAR SENSOR  
DRS25A  
NMEA 2000  
Equipment  
Power Supply Unit  
PSU-013  
12-24 VDC  
Multi Function  
Display BlackBox  
MFDBB  
OR  
Multi Function Display  
MFD8/12  
RECTIFIER  
RU-1746B  
: Standard Supply  
: Optional Supply  
: Local Supply  
12-24 VDC  
100/110/220/230 VAC  
iii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
EQUIPMENT LISTS  
Standard supply  
Name  
Type  
Code No.  
Qty  
1
Remarks  
Radar Sensor XN10A-RSB-118-092  
XN12A-RSB-118-093  
-
For DRS4A, w/CP03-32601  
For DRS6A, w/CP03-32601  
1
XN12A-RSB-118-094  
-
1
For DRS12A, 1255 mm,  
w/CP03-32601  
XN13A-RSB-118-094  
XN12A-RSB-118-095  
XN13A-RSB-118-095  
DRS2D  
1
1
1
1
1
1
For DRS12A, 1795 mm,  
w/CP03-32601  
-
-
-
-
-
For DRS25A, 1255 mm, w/CP03-  
32601  
For DRS25A, 1795 mm, w/CP03-  
32601  
Radome, 2 kW,  
w/CP03-32101  
DRS4D  
Radome, 4 kW,  
w/CP03-32101  
Power Supply PSU-013  
Unit  
For DRS25A, w/SP03-16101 and  
CP03-32700  
Installation  
Materials  
CP03-32101  
CP03-32601  
CP03-32200  
001-025-270 1 set For DRS2D/4D  
001-025-780 1 set For DRS4A/6A/12A/25A  
000-011-720  
000-011-721  
000-011-722  
000-011-723  
000-011-990  
000-011-991  
000-011-992  
000-011-993  
1
Two-way cable, MOD-ASW0001-  
100+, 10 m, for DRS2D/4D/4A/6A/12A  
CP03-32300  
CP03-32400  
CP03-32500  
CP03-32800  
CP03-32810  
CP03-32820  
CP03-32830  
Two-way cable, MOD-ASW0001-  
150+, 15 m, for DRS2D/4D/4A/6A/12A  
Two-way cable, MOD-ASW0001-  
200+, 20 m, for DRS2D/4D/4A/6A/12A  
Two-way cable, MOD-ASW0001-  
300+, 30 m, for DRS2D/4D/4A/6A/12A  
Two-way cable, MOD-ASW0002-  
100+, 10 m, for DRS25A  
Two-way cable, MOD-ASW0002-  
150+, 15 m, for DRS25A  
Two-way cable, MOD-ASW0002-  
200+, 20 m, for DRS25A  
Two-way cable, MOD-ASW0002-  
300+, 30 m, for DRS25A  
iv  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Optional supply  
Name  
Type  
Code No.  
Qty  
Remarks  
Power Supply PSU-012  
Unit  
-
1 set  
Gasket  
OP03-203  
OP03-205  
OP03-206  
001-025-290  
001-025-790  
1
For DRS2D/4D, φ10 NMEA2000  
cable  
For DRS4A/6A, φ10 NMEA2000  
cable  
001-035-290  
For DRS25A, φ10 NMEA2000 cable  
For NMEA2000 connection with a unit  
For LAN cable extension  
2 m  
Resister Assy OP03-204  
001-025-300  
1
1
1
1
1
1
1
1
1
1
1
Joint Box  
TL-CAT-012  
000-167-140-10  
000-167-175-10  
000-167-176-10  
000-167-177-10  
LAN Cable  
MOD-Z072-020+  
MOD-Z072-050+  
MOD-Z072-100+  
5 m  
10 m  
Cable Assy  
M12-05BFFM-010 000-167-965-10  
M12-05BFFM-020 000-167-966-10  
M12-05BFFM-060 000-167-967-10  
NMEA2000, φ6, w/connector, 1 m  
NMEA2000, φ6, w/connector, 2 m  
NMEA2000, φ6, w/connector, 6 m  
NMEA2000, φ10, w/connector, 1 m  
NMEA2000, φ10, w/connector, 2 m  
NMEA2000, φ10, w/connector, 6 m  
CB-05BFFM-010  
CB-05BFFM-020  
CB-05BFFM-060  
000-167-971-10  
000-167-972-10  
000-167-973-10  
v
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. MOUNTING  
1.1 Mounting Considerations  
• The radar sensor is generally installed either on top of the wheelhouse or on the radar mast on  
a suitable platform. Locate the radar sensor where there is a good all-round view. Any obstruc-  
tion will cause shadow and blind sectors. A mast for instance, with a diameter considerably less  
than the horizontal beamwidth of the radiator, will cause only a small blind sector, but a horizon-  
tal spreader or crosstrees in the same horizontal plane as the radar sensor would be a much  
more serious obstruction; you would need to place the radar sensor well above or below it.  
• It is rarely possible to place the radar sensor where a completely clear view in all directions is  
available. Thus, you should determine the angular width and relative bearing of any shadow  
sectors for their influence on the radar at the first opportunity after fitting.  
• A magnetic compass will be affected if the radar sensor is placed too close to it. Observe the  
compass safe distances mentioned in the SAFETY INSTRUCTIONS to prevent interference to  
a magnetic compass.  
• Do not paint the radiator aperture and radome to ensure proper emision of the radar waves.  
• When this radar sensor is to be installed on large vessels, consider the following points:  
• The two-way cable run between the radar sensor and MFDBB, MFD8, MFD12 or PSU-012  
comes in lengths of 10 m, 15 m, 20 m or 30 m.  
• Deposits and fumes from a funnel or other exhaust vent can adversely affect the aerial per-  
formance and hot gases may distort the radiator portion. The radar sensor must not be  
mounted where the temperature is more than 55 degrees centigrade.  
As shown in the figure below, the radar sensor may be installed on a common mast or on the radar  
mast.  
(a) Common mast  
(b) Radar mast  
For DRS4A/6A/12A  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
Radar sensor  
Radar sensor  
Radar sensor  
Radar sensor  
For DRS2D/4D  
1.2 Mounting Procedure for DRS2D/4D  
1. Remove mounting hardware at the bottom of the radar sensor, four each of hex bolts  
(M10x20), spring washers and flat washers. Save the spring washers and flat washers to use  
them to fix the radome base to the platform, at step 3. If the thickness of the mounting platform  
is 5 mm or less, also save the bolts.  
Screws  
(two screws on other side)  
Stern  
Cable entry  
Flat washer  
Bow  
Spring washer  
Hex bolt (M10 x 20)  
2. Construct a platform (steel or aluminum) 6-10 mm in thickness referring to the outline drawing  
at the back of this manual. Fasten the platform to the mounting location. Next, position the  
base so the cable entrance is facing the stern.  
Note: When drilling holes in the platform, be sure they are parallel with the fore and aft line.  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. Use the hex bolts*, flat washers and spring washers removed at step 1, and fasten the  
radome base to the platform. The torque should be between 19.6-24.5Nzm.  
*If the thickness of the platform is 6-10 mm, use M10x25 bolts (supplied). For thicker platform, use  
locally supplied bolts.  
Transceiver  
module  
Antenna base  
assy.  
5 mm or under: M10x20 (local supply)  
L
6-10 mm:  
M10x25 (supplied)  
over 10 mm:  
locally supplied bolts  
As for length, use the bolt  
the "L" shown in the figure  
in left becomes 10 to 15 mm.  
Flat  
washer  
Platform  
Spring  
washer  
Hex bolt  
Apply silicone sealant.  
(M10 x 25  
or M10 x 20)  
4. Mount the cover tentatively. The cover is opened for wiring at Chapter 2.  
1.3 Mounting Procedure for DRS4A/6A/12A/25A  
Refer to the outline drawing at the back of this manual, and drill five holes in the mounting platform:  
four holes of 15 mm in diameter for fixing the radar sensor and one hole of 25-30 mm in diameter  
for the signal cable. The outline drawing shows two cable entrance holes, one on the radar sensor  
and one on the rubber mat. Use only the one on the rubber mat.  
1.3.1 Fastening the radiator to the radiator bracket  
1. Remove the radiator cap from the radiator bracket.  
2. Coat the surface of the radiator bracket with silicone sealant as shown in the figure below.  
RADIATOR BRACKET  
(top view)  
10mm  
(Do not coat.)  
Coat hatched area with  
silicone sealant.  
3. Coat threaded holes on the antenna radiator with silicone sealant.  
4. Grease the O-ring and set it to the radiator bracket.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
5. Coat the hex bolts (4 pcs.) with silicone sealant. Fasten the antenna radiator to the radiator  
bracket with the hex bolts, flat washers and spring washers supplied with the radiator.  
Antenna  
radiator  
Coat threaded  
holes with silicone  
sealant.  
O-ring  
Radiator bracket  
Flat washer  
Spring washer  
Hex bolt  
(M8 x 30)  
Coat bolts with  
silicone sealant.  
1.3.2 Mounting the radar sensor  
The radar sensor can be mounted using the fixing holes on the outside (200 x 200 mm) or inside  
(140 x 150 mm) the radar sensor.  
Using outside fixing holes of radar sensor  
Use the hex bolts (supplied) to mount the radar sensor as below.  
1. Lay the corrosion-proof rubber mat (supplied) on the mounting platform.  
Rubber mat  
Ground terminal  
Bow mark  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
2. Lay the radar sensor on the mounting platform, orienting it as shown below. (The hinges must  
face toward the stern.)  
BOW  
STERN  
Hinge  
CAUTION  
Do not lift the radar sensor by the  
radiator; lift it by the housing.  
The radiator may be damaged.  
3. Insert four hex bolts (M12 x 60, supplied) and seal washers (φ30, supplied) from the top of the  
housing, as shown below.  
Hex. bolt  
Seal washer  
(Face projecting part down.)  
Flat washer  
Spring washer  
Nut  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. Pass flat washers (M12, supplied), spring washers (M12, supplied) and nuts (M12, supplied)  
onto hex. bolts. Fasten by tightening nuts. Do not fasten by tightening the hex. bolts; seal  
washers may be damaged.  
Seal washer  
Antenna  
unit  
Rubber mat  
Mounting  
platform  
Silicone  
sealant  
Flat washer  
5. Coat flat washers, spring washers, nuts and exposed parts of bolts with anticorrosive sealant.  
6. Prepare ground point in mounting platform (within 300 mm of ground terminal on radar sen-  
sor) using M6 x 25 bolt, nut and flat washer (supplied).  
7. Run the ground wire (RW-4747, 340 mm, supplied) between the ground terminal and ground  
point.  
8. Coat ground terminal and ground point with silicone sealant as shown below.  
Hex. bolt  
Flat washer  
Ground  
Flat washer  
wire  
Spring washer  
Hex. nut  
Silicone  
OR  
GROUND  
POINT  
sealant  
Hex. nut  
Ground  
wire  
Spring washer  
Flat washer  
Hex. nut  
Weld here.  
GROUND  
TERMINAL  
Silicone  
sealant  
Ground  
wire  
antenna  
unit  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Using inside fixing holes of the sensor housing  
If this radar is replacing a FURUNO radar whose mounting dimensions are the same as this one  
(140 x 150 mm), it may be possible to use its mounting platform. This method requires removal of  
the RF unit from the radar sensor to access inside fixing holes. Use hex bolts, flat washers, spring  
washers and nuts (local supply) to mount the radar sensor.  
1. Unfasten four bolts from the cover to open the radar sensor.  
2. Unplug the PCS connector from RF unit.  
3. Separate upper chassis from lower chassis by removing two bolts (M8x25).  
4. Remove RF unit by unfastening two hex bolts and two fixing bolt.  
Upper chassis  
Bolt  
M8x25,  
2 pcs.  
RF unit  
PCS connector  
Hex bolt  
2 pcs.  
Fixing bolt  
(2 pcs.)  
Inside fixing holes  
Lower chassis  
(Example: DRS4A/6A)  
For DRS12A/25A, unfasten four hex bolts, not two fixing bolts, to remove the RF unit.  
5. Lay the corrosion-proof rubber mat (supplied) on the mounting platform.  
6. Fasten the lower chassis to the mounting platform with hex bolts, spring washers, flat washers  
and nuts (local supply), and then coat flat washers, nuts and exposed parts of bolts with sili-  
cone sealant. Cut a slit in the rubber bushing and insert bolt into the bushing. Do not use seal  
washers.  
7. Remount RF unit.  
8. Coat outside fixing holes with silicone sealant and then attach caps (supplied) to holes.  
9. Do steps 6-8 on page 6.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
1.4 Mounting of Power Supply Unit  
PSU-013 (for DRS25A)/PSU-012 (Option)  
For combinations shown below, the optional power supply unit PSU-012 (Code No.: 000-011-756)  
is necessary. The PSU-013 is required for any DRS25A installation.  
DRS2D/4D  
NO  
DRS4A  
YES  
NO  
DRS6A  
YES  
NO  
DRS12A  
MFD8  
YES  
YES  
NO  
NO  
MFD12  
MFDBB  
NO  
NO  
NO  
Contents of PSU-0012/013  
Type Code No.  
Name  
Qty  
Remarks  
Power supply unit  
PSU-012  
PSU-013  
-
1
-
for DRS25A  
5 m  
Cable assy  
LAN cable  
VL3P-VV-S2X2C-AA050  
MOD-Z072-050+  
000-152-217-10  
000-167-176-10  
000-158-850-10  
000-155-839-10  
000-157-874-10  
1
1
4
2
2
5 m, standard  
Self-tapping screw 4x20, SUS304  
Fuse*  
FGB0 250V 10A  
FGB0 250V 15A  
For 24 VDC  
For 12 VDC  
*Note: The power supply unit is shipped with 15A fuse. Replace fuse with 10A when using the unit  
with 24V ship’s battery.  
The power supply unit can be installed almost anywhere provided the following conditions are met:  
• Location is dry, well ventilated.  
• Sufficient maintenance space is available.  
• Installated within 2, 5 or 10 m (2 and 10 m: optional supply) from the multi function display.  
Do not install the power supply unit on the overhead; install it on the deck or bulkhead. Use four  
tapping screws (4x20, supplied) to fasten the power supply unit.  
Self-tapping screw  
(4x20, 4 pcs.)  
Power supply unit PSU-012/013  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
2. WIRING  
The MFDBB, MFD8, MFD12 or PSU-012 connects to the radar sensor with the two-way cable  
MOD-ASW0001 (MOD-ASW0002 for DRS25A).In order to minimize the chance of picking up  
electrical interference, avoid where possible routing the two-way cable near other onboard elec-  
trical equipment. After passing the cable through the hole in the radar sensor, apply sealing com-  
pound around the hole for waterproofing. When connecting to other NMEA2000 equipment, use  
the optional cable M12-05BFFM 6) or CB-05BFFM (φ10).  
NOTICE  
Before connecting or disconnecting the  
NMEA2000 cable, turn off the radar sensor.  
The sensor may become damaged if the power is  
not turned off.  
Wiring for DRS2D/4D/4A/6A/12A without PSU-012  
RADAR SENSOR  
DRS2D/DRS4D  
RADAR SENSOR  
DRS4A/DRS6A/DRS12A  
NMEA2000 cable  
M12-05BFFM (φ6) or  
CB-05BFFM (φ10)  
Two-way cable  
MOD-ASW0001  
(10/15/20/30 m)  
NMEA2000  
Equipment  
NMEA2000  
Equipment  
NMEA2000 cable  
M12-05BFFM (φ6) or  
CB-05BFFM (φ10)  
: Standard Supply  
: Optional Supply  
To Multi Function Display BlackBox  
MFDBB or Multi Function Display  
MFD8/12  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
Wiring for DRS2D/4D/4A/6A/12A with PSU-012  
Radar Sensor  
DRS2D/DRS4D  
Radar Sensor  
DRS4A/DRS6A/DRS12A  
NMEA2000 cable  
M12-05BFFM (φ6) or  
CB-05BFFM (φ10)  
Two-way cable  
MOD-ASW0001  
(10/15/20/30 m)  
NMEA2000  
Equipment  
NMEA2000  
Equipment  
NMEA2000 cable  
M12-05BFFM (φ6) or  
CB-05BFFM (φ10)  
(LAN)  
(Power)  
Power Supply Unit  
PSU-012  
12-24 VDC  
Power cable  
VL3P-VV-S2X2C-AA050  
(supplied with PSU-012)  
: Standard Supply  
LAN cable  
: Optional Supply  
: Local Supply  
MOD-Z072  
-5 m: supplied  
-2, 10 m: option  
To ship's ground  
Ground wire  
(Local supply, IV-2sq)  
To Multi Function Display BlackBox  
MFDBB or Multi Function Display  
MFD8/12  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Wiring for DRS25A  
RADAR SENSOR  
DRS25A  
NMEA2000 cable  
M12-05BFFM (φ6) or  
CB-05BFFM (φ10)  
NMEA2000  
Equipment  
Two-way cable  
MOD-ASW0002 cable  
(10/15/20/30 m)  
(POWER)  
(LAN)  
Power cable  
VL3P-VV-S2X2C-AA50  
Power Supply Unit  
PSU-013  
LAN cable  
MOD-2072-050  
12-24 VDC  
Ground wire  
(Local supply, IV-2sq)  
To Multi Function Display BlackBox  
MFDBB or Multi Function Display  
MFD8/12  
To ship’s ground  
: Standard Supply  
: Optional Supply  
: Local Supply  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.1 Wiring inside DRS2D/4D  
Two-way cable connection  
1. Unfasten three screws at the bottom of the mounting base to remove the fixing plate for the  
gasket.  
Fixing plate  
(for gasket)  
2. Remove the gasket, and pass the two-way cable MOD-ASW0001.  
3. Fasten the shield of the cable (power) with the cable clamp in the radar sensor, and connect  
the connector of cable (power) to the power terminal.  
4. Connect the RJ-45 connector of the cable (LAN) to the LAN terminal in the radar sensor.  
LAN terminal  
Power terminal  
Fix the cable (LAN)  
with this locking saddle.  
Fix the shield cable  
(power) with this clamp.  
5. Push cables of the two-way cable into the slits of the gasket inside the radar sensor.  
Note: The ends of the gasket are different. Larger end should be up.  
Large  
Up  
Small  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6. Slide the gasket on cables so that the amount of cable above the gasket is lower than the RF  
chassis.  
This height should  
be lower than the RF  
unit when installed to  
the bottom of the sensor.  
Cable  
Gasket  
RF unit  
Gasket  
Note: If the two-way cable touches the platform near the mounting base, wind vinyl tape around  
the cable at the point where it is bent.  
7. Confirm that the rubber gasket is properly positioned and that the triangle mark on the cover is  
aligned with the triangle mark on the mounting base, then tighten the fixing screws for the  
cover.  
Triangle marks  
Cover  
Mounting  
base  
Connecting to NMEA2000 equipment  
To connect NMEA2000 equipment to the sensor, wire an optional NMEA2000 cable, M12-05BFFM  
(φ6) or CB-05BFFM (φ10), as shown below. Also, the gasket at the bottom of mounting base must  
be replaced.  
1. Do steps 1 to 4 on page 12.  
2. Refer to the figure below, and fabricate the cable M12-05BFFM (φ6) or CB-05BFFM (φ10).  
5
15 (Area fastened with the cable clamp)  
M12-05BFFM cable  
Shield  
100  
Fabrication of cable M12-05BFFM (φ6)  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5
15  
Shield  
CB-05BFFM cable  
370  
Fasten the cable tie (supplied) within  
15 mm from the end of vinyl sheath.  
Wind vinyl tape.  
(supplied)  
CB-05BFFM cable  
65  
20  
15 (Area fastened with the cable clamp)  
Fabrication of CB-05BFFM cable  
3. Insert wires of cable M12-05BFFM (φ6) or CB-05BFFM (φ10) to the NMEA connector inside the  
radar sensor, consulting the label on the connector for location. As for shield, use the cable  
clamp shown below to fasten it to the RF chassis.  
Cable  
M12-05BFFM (φ6)  
CB-05BFFM (φ10)  
Use the clamp in the plastic bag supplied  
inside the radar sensor.  
Use the clamp supplied with the optional gasket  
(Type: OP03-203, Code No.: 001-025-290)  
Clamp  
Zoom up  
Attach the cable clamp  
using this screw.  
Cable clamp  
(Face projecting part down.)  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. Push LAN and POWER cables of the two-way cable and cable M12-05BFFM (φ6) or CB-  
05BFFM (φ10) into the slits of the gasket inside the mounting base. Depending on the  
NMEA2000 cable used, replace the gasket as shown below.  
Cable type  
Gasket  
M12-05BFFM (φ6)  
CB-05BFFM (φ10)  
Use the gasket supplied in the plastic Use the optional gasket. (Type: OP03-203,  
bag inside the radar sensor. Code No.: 001-025-290)  
Note: The ends of the gasket are different. Larger end should be up)  
Large  
Up  
Small  
5. Slide the gasket on cables so that the amount of cable above the gasket is lower than the RF  
chassis.  
This height should  
be lower than the RF  
unit when attaching to  
the bottom of the sensor.  
Gasket  
Cable  
RF unit  
RF unit  
Gasket  
Note: If the two-way cable touches the platform near the radar sensor base, wind vinyl tape  
around the cable at the point where is bent.  
6. Confirm that the rubber gasket is properly positioned and that the triangle mark on the cover is  
aligned with the triangle mark on the mounting base, then tighten the fixing screws for the  
cover.  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.2 Wiring inside DRS4A/6A/12A/25A  
Two-way cable connection  
If you have no NMEA2000 equipment to connect, use the MOD-ASW0001 cable (standard sup-  
ply).  
1. Open the radar sensor cover by loosening four bolts, and fix the stay for safety purpose.  
2. Unfasten four bolts to detach the plate, gasket, washer and lid. Discard the lid at the bottom of  
the hole for the gasket.  
Plate  
Gasket  
Washer  
Lid  
Stay  
3. Pass the two-way cable MOD-ASW0001 (MOD-ASW0002 for DRS25A) through the bottom of  
the chassis and washer.  
4. Fasten the shield of the power cable of the two-way cable (part of the foil) with the cable  
clamp in the radar sensor, and then connect the power cable to the power terminal as shown  
on next page.  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5. Attach the LAN cable of the two-way cable to the LAN terminal in the radar sensor.  
Fix the power cable at the foil part  
with this cable clamp.  
Power cable  
White  
Black  
Power terminal  
LAN cable  
RF unit  
LAN terminal  
DRS4A/6A/12A  
Fix the power cable at the copper  
foil part with this cable clamp.  
Gasket  
LAN cable  
White  
Power terminal  
Blue  
Red  
Black  
Power cable  
LAN terminal  
DRS25A  
6. Refer to the illustration shown below, and attach the gasket to the two-way cable, inserting the  
cable into the slits on the gasket.  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7. Slide the gasket on cables so that the amount of cable above the gasket is lower than the RF  
chassis.  
This height should be lower than the  
RF unit when installed to the bottom  
of the sensor.  
Cable  
RF unit  
Gasket  
Gasket  
Washers  
8. Push the gasket and washers into the hole at the bottom of the radar sensor, then fasten four  
pan head screws to fix the plate to the sensor.  
9. Release the stay and close the cover.  
Note: When closing the cover, set the gaskets to grooves in the bottom chassis, then tighten bolts.  
BOTTOM  
CHASSIS  
GROOVE  
.
Torque : 9.8 ±0.1 N m  
GASKET  
HEX BOLT  
Connecting to NMEA2000 equipment  
To connect NMEA2000 equipment to the sensor, use an optional NMEA2000 cable, M12-05BFFM  
(φ6) or CB-05BFFM (φ10). Also, the gasket at the bottom of the antenna sensor must be replaced.  
1. Do steps 1 to 5 on pages 16 and 17.  
2. Fabricate the cable M12-05BFFM (φ6) or CB-05BFFM (φ10) as shown below.  
5
95  
Cable M12-05BFFM  
or CB-05BFFM  
Drain wire  
3. Pass the cable through the bottom of the chassis.  
4. Insert wires of the cable M12-05BFFM (φ6) or CB-05BFFM (φ10) to the NMEA connector inside  
the radar sensor, consulting the label on the connector for location. As for drain wire, attach  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
the crimp-on lug (pre-attached at the bottom of the chassis) to the drain wire, and fasten it with  
the screw shown below.  
A
view  
NMEA connector  
NMEA connector  
Crimp-on lug  
A
Drain wire  
Fasten the drain wire with this screw.  
NMEA cable  
RF unit  
5. Depending on the NMEA2000 used, replace the gasket as shown below.  
DRS4A/6A/12A  
Cable type  
Gasket  
M12-05BFFM (φ6)  
CB-05BFFM (φ10)  
Use the gasket supplied in the plastic Use the optional gasket. (Type: OP03-205,  
bag inside the radar sensor.  
Code No.: 001-025-790)  
DRS25A  
Cable type  
Gasket  
M12-05BFFM (φ6)  
CB-05BFFM (φ10)  
Use the gasket supplied in the plastic Use the optional gasket. (Type: OP03-206,  
bag inside the radar sensor. Code No.: 001-035-290)  
6. Refer to the illustration shown on next page, and attach the gasket to the two-way cable  
inserting the cable into the slits on the gasket.  
7. Slide the gasket on cables so that the amount of cable above the gasket is lower than the RF  
chassis.  
This height should be lower than the  
RF unit when installed to the bottom  
of the sensor.  
Cable  
Gasket  
Washer  
RF unit  
Gasket  
8. Do steps 8 and 9 on page 18.  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.3 Wiring of Power Supply Unit PSU-013 (for  
DRS25A)  
1. Detach the body cover by hand.  
2. Loosen six pan head screws (M3x8) and slide the shield cover upward to remove it.  
3. Unfasten four pan head screws (M14x10) to remove two cable clamps.  
Body cover  
Shield cover  
Pan head screws  
(M4x10, 4 pcs.)  
Cable clamps  
Pan head screws  
(M3x8, 6 pcs.)  
4. Connect the cable VL3P-VV-S2X2C-AA50 and MOD-ASW0002 cables (supplied) to appropri-  
ate connectors in the power supply unit as shown below.  
1: Red  
2: N. C.  
White  
Black  
3: Blue  
2: Black  
1: White  
VL3P-VV-S2X2C-AA50 cable  
MOD-ASW0002 cable  
(Power)  
5. Remove two cable clamps, shield cover and body cover in that order.  
6. Connect other cables.  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.4 Wiring inside Power Supply Unit PSU-012  
(Option)  
1. Detach the body cover by hand.  
2. Loosen six pan head screws (M3x8) and slide the shield cover upward to remove it.  
3. Unfasten two pan head screws (M4x12) to remove the cable clamp.  
Body cover  
Shield cover  
Pan head screw  
(M4x12, 2 pcs.)  
Cable clamp  
Pan head screw  
(M3x8, 6 pcs.)  
4. Connect the cable VL3P-VV-S2X2C-AA050 (supplied) to the power connector in the PSU-  
012.  
For black wire  
For white wire  
Put the cable VL3P-VV-S2X2C-AA050 here at the shield part.  
5. Remount the cable clamp, shield cover and body cover in that order.  
6. Connect other cables.  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
A-1  
CODE NO.  
TYPE  
001-025-270-00  
CP03-32101  
03HA-X-9401 -0  
1/1  
工事材料表  
INSTALLATION MATERIALS  
数量  
番 号  
NO.  
名  称  
NAME  
型名/規格  
略  図  
OUTLINE  
用途/備考  
REMARKS  
Q'TY  
DESCRIPTIONS  
テイコウ組品  
120 OHM-1007#24-L50  
CODE  
1
2
3
4
1
RESISTOR ASSEMBLY  
NO.  
000-167-746-10  
M10 SUS304  
M10 SUS304  
ミガキ平座金  
4
4
4
FLAT WASHER  
000-167-232-10  
000-864-131-00  
CODE  
NO.  
M10 SUS304  
バネ座金  
M10 SUS304   
SPRING WASHER  
000-167-233-10  
000-864-261-00  
CODE  
NO.  
六角スリワリ ボルト  
M10X25 SUS304  
CODE  
HEX.BOLT (SLOTTED  
HEAD)  
NO.  
000-162-883-10  
型式/コード番号が2段の場合、下段より上段に代わる過渡期品であり、どちらかが入っています。 なお、品質は変わりませ  
ん。  
TWO TYPES AND CODES MAY BE LISTED FOR AN ITEM. THE LOWER PRODUCT MAY BE SHIPPED IN PLACE OF THE UPPER  
PRODUCT. QUALITY IS THE SAME.  
(略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.)  
03HA-X-9401  
FURUNO ELECTRIC CO .,LTD.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
A-2  
CODE NO.  
TYPE  
001-025-780-00  
CP03-32601  
03GY-X-9401 -2  
1/2  
RSB-118-092/093/094  
工事材料表  
INSTALLATION MATERIALS  
数量  
Q'TY  
番 号  
NO.  
名  称  
NAME  
型名/規格  
DESCRIPTIONS  
03-001-3002-0 ROHS  
略  図  
OUTLINE  
用途/備考  
REMARKS  
シールワッシャ  
03-001-3002-0  
1
2
SEAL WASHER  
4
1
4
1
4
4
4
4
3
1
300-130-020-10  
300-130-020-00  
CODE  
NO.  
防蝕ゴム  
03-142-3001-0 ROHS  
CODE  
CORROSION-PROOF  
RUBBER MAT  
NO.  
100-275-580-10  
キャップ  
CAP  
040-4010  
3
CODE  
NO.  
000-164-929-10  
テイコウ組品  
120 OHM-1007#24-L50  
CODE  
4
RESISTOR ASSEMBLY  
NO.  
000-167-746-10  
バネ座金  
M12 SUS304  
CODE  
5
SPRING WASHER  
NO.  
000-167-397-10  
ミガキマル平座金  
FLAT WASHER  
M12 SUS304  
CODE  
6
NO.  
000-167-446-10  
六角ナット 1シュ  
HEX.NUT  
M12 SUS304  
CODE  
7
NO.  
000-167-491-10  
六角ボルト(全ネジ)  
HEX. BOLT  
M12X60 SUS304  
CODE  
8
NO.  
000-162-813-10  
ミガキ平座金  
M6 SUS304  
CODE  
9
FLAT WASHER  
NO.  
000-158-854-10  
バネ座金  
M6 SUS304  
CODE  
10  
SPRING WASHER  
NO.  
000-158-855-10  
型式/コード番号が2段の場合、下段より上段に代わる過渡期品であり、どちらかが入っています。 なお、品質は変わりませ  
ん。  
TWO TYPES AND CODES MAY BE LISTED FOR AN ITEM. THE LOWER PRODUCT MAY BE SHIPPED IN PLACE OF THE UPPER  
PRODUCT. QUALITY IS THE SAME.  
(略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.)  
03GY-X-9401  
FURUNO ELECTRIC CO .,LTD.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
A-3  
CODE NO.  
TYPE  
001-025-780-00  
CP03-32601  
03GY-X-9401 -2  
2/2  
RSB-118-092/093/094  
工事材料表  
INSTALLATION MATERIALS  
数量  
Q'TY  
番 号  
NO.  
名  称  
NAME  
型名/規格  
DESCRIPTIONS  
略  図  
OUTLINE  
用途/備考  
REMARKS  
六角ナット 1シュ  
M6 SUS304  
11  
12  
13  
HEX.NUT  
1
1
1
CODE  
NO.  
000-158-856-10  
六角ボルト  
HEX.BOLT  
M6X25 SUS304  
CODE  
NO.  
000-162-871-10  
アース線  
RW-4747-1  
CODE  
GROUND WIRE  
NO.  
000-566-000-01  
型式/コード番号が2段の場合、下段より上段に代わる過渡期品であり、どちらかが入っています。 なお、品質は変わりませ  
ん。  
TWO TYPES AND CODES MAY BE LISTED FOR AN ITEM. THE LOWER PRODUCT MAY BE SHIPPED IN PLACE OF THE UPPER  
PRODUCT. QUALITY IS THE SAME.  
(略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.)  
03GY-X-9401  
FURUNO ELECTRIC CO .,LTD.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
A-4  
CODE NO.  
TYPE  
03HA-X-9402 -0  
1/1  
RADAR SENSOR  
DRS2D/4D  
工事材料表  
INSTALLATION MATERIALS  
数量  
Q'TY  
番 号  
NO.  
名  称  
NAME  
型名/規格  
略  図  
OUTLINE  
用途/備考  
REMARKS  
DESCRIPTIONS  
選択 TO BE SELECTED  
選択 TO BE SELECTED  
選択 TO BE SELECTED  
選択 TO BE SELECTED  
ケーブル組品  
MOD-ASW0001-100+  
CODE  
1
2
3
4
1
1
1
1
CABLE ASSY.  
NO.  
000-167-635-00  
ケーブル組品  
MOD-ASW0001-150+  
CODE  
CABLE ASSY.  
NO.  
000-167-636-00  
ケーブル組品  
MOD-ASW0001-200+  
CODE  
CABLE ASSY.  
NO.  
000-167-637-00  
ケーブル組品  
MOD-ASW0001-300+  
CODE  
CABLE ASSY.  
NO.  
000-167-638-00  
標準は15mであるが必要により選択可  
STANDARD LENGTH IS 15M. OTHER LENGTHS ARE ALSO AVAILABLE.  
型式/コード番号が2段の場合、下段より上段に代わる過渡期品であり、どちらかが入っています。 なお、品質は変わりませ  
ん。  
TWO TYPES AND CODES MAY BE LISTED FOR AN ITEM. THE LOWER PRODUCT MAY BE SHIPPED IN PLACE OF THE UPPER  
PRODUCT. QUALITY IS THE SAME.  
(略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.)  
03HA-X-9402  
FURUNO ELECTRIC CO .,LTD.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
A-5  
CODE NO.  
TYPE  
03HC-X-9402 -0  
1/1  
RADAR SENSOR  
DRS25A  
工事材料表  
INSTALLATION MATERIALS  
数量  
Q'TY  
番 号  
NO.  
名  称  
NAME  
型名/規格  
略  図  
OUTLINE  
用途/備考  
REMARKS  
DESCRIPTIONS  
*選択 TO BE  
SELECT  
ケーブル組品  
MOD-ASW0002-100+  
CODE  
1
2
3
4
CABLE ASSY.  
1
1
1
1
NO.  
000-167-639-00  
*選択 TO BE  
SELECT  
ケーブル組品  
MOD-ASW0002-150+  
CODE  
CABLE ASSY.  
NO.  
000-167-640-00  
*選択 TO BE  
SELECT  
ケーブル組品  
MOD-ASW0002-200+  
CODE  
CABLE ASSY.  
NO.  
000-167-641-00  
*選択 TO BE  
SELECT  
ケ^ブル組品  
MOD-ASW0002-300+  
CODE  
CABLE ASSY.  
NO.  
000-167-642-00  
型式/コード番号が2段の場合、下段より上段に代わる過渡期品であり、どちらかが入っています。 なお、品質は変わりませ  
ん。  
TWO TYPES AND CODES MAY BE LISTED FOR AN ITEM. THE LOWER PRODUCT MAY BE SHIPPED IN PLACE OF THE UPPER  
PRODUCT. QUALITY IS THE SAME.  
(略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.)  
03HC-X-9402  
FURUNO ELECTRIC CO .,LTD.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
D-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
D-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
D-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
D-4  
2/Apr/08 R.Esumi  
Download from Www.Somanuals.com. All Manuals Search And Download.  
D-5  
Oct.15'07 R.Esumi  
Download from Www.Somanuals.com. All Manuals Search And Download.  
S-1  
( - ) 2  
( + ) 1  
J 3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
S-2  
( - ) 2  
( + ) 1  
J 3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
S-3  
( - ) 2  
( + ) 1  
J 3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
S-4  
( - ) 2  
( + ) 1  
J 3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
The paper used in this manual  
is elemental chlorine free.  
・FURUNO Authorized Distributor/Dealer  
9-52 Ashihara-cho,  
Nishinomiya, 662-8580, JAPAN  
Telephone : +81-(0)798-65-2111  
Fax  
: +81-(0)798-65-4200  
A : JAN 2008  
.
Printed in Japan  
All rights reserved.  
B1 : APR. 17, 2008  
Pub. No. IME-35670-B1  
(HIMA ) DRS-2D/4D/4A-25A  
*00016745111*  
*00016745111*  
* 0 0 0 1 6 7 4 5 1 1 1 *  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Echo Blower PB 265LN User Manual
Edifier Enterprises Canada Speaker System R251 User Manual
Fireboy Xintex LTD Fire Extinguisher HFC 227ea User Manual
GarrettCom Switch H80B User Manual
GE Freezer FCM 7 User Manual
GenTran Portable Generator 6370C User Manual
GE Recording Equipment DVMRe 16eZT User Manual
Global Technology Associates Kitchen Entertainment Center GB 2000X User Manual
GMC Automobile 2006 GMC Envoy User Manual
Goldstar Air Conditioner LWC061JGMK1 User Manual