SPARC Enterprise T5120 Server Getting Started Guide
This guide describes the minimum steps you must perform to power on and boot your server for the first time
using the preinstalled Solaris™ Operating System (Solaris OS).
FIGURE 1 SPARC Enterprise T5120 Server
Shipping Contents
Quantity
Item
1
2
1
1
1
2
1
Server
RJ-45 Ethernet cable
RJ-45 to DB-25 adapter (crossover)
RJ-45 to DB-9 adapter (crossover)
Wrist strap
Power cords (packaged separately)
Rackmounting kit with cable
management assembly
Before You Begin
For quick installation and configuration, follow these steps. For more detailed information, refer to the complete
online product documentation set at: http://www.fujitsu.com/sparcenterprise/manual/
Understand the following information before you set up the server for the first time:
■
■
Do not apply power until instructed to do so – This system includes a service processor (SP) that is used to
configure and boot the host server. To properly configure the host server and view SP messages, do not apply
AC power to the server until the SP and host networking connections are made, as described in this guide.
Choose the best instructions for your situation – The quick setup instructions in this guide work for any
networking environment, and require the use of a terminal device for connection to a serial port. If you have
a networking environment running DHCP, you can configure your system using the Ethernet management
port. To take advantage of the DHCP setup method, refer to the online installation guide in the online product
documentation set at: http://www.fujitsu.com/sparcenterprise/manual/
Download from Www.Somanuals.com. All Manuals Search And Download.
Quick Setup Instructions
1. Unpack the server, and check that you received all of the shipping contents (FIGURE 1).
2. Place the server in its intended location for verification.
For rackmounting instructions, refer to the instructions included with the rail kit, the service label on the
server, and to the online SPARC Enterprise T5120 and T5220 Servers Installation Guide.
3. Connect a serial cable between the server’s SER MGT port (FIGURE 2) and a terminal device.
This connection provides your initial communication with the SP.
The device must be set up to communicate using 9600 baud, 8 bit, no parity, 1 stop bit. A null modem
configuration is needed, meaning the transmit and receive signals are reversed (crossed over) for DTE to
DTE communications. You can use the supplied RJ-45 crossover adapters with a standard RJ-45 cable to
achieve the null modem configuration.
FIGURE 2 Server Connections
SER MGT
RJ-45
NET MGT
RJ-45
NET 0 to NET 3
RJ-45
Host to Ethernet
SP to Ethernet
(Optional)
RJ-45 to DB-25
crossover
adapter
device
RJ-45 to DB-9
crossover
adapter
n
Numbered cables
correspond to setup steps.
4. (Optional) Connect an Ethernet cable between the server’s NET MGT port (FIGURE 2) and the network to
which future connections to the SP and host will be made.
After the initial configuration of the system using the SER MGT port, communication with the SP and host is
usually performed through this Ethernet interface.
5. Connect an Ethernet cable between one of the server’s NET ports (FIGURE 2) and the network to which the
server will communicate.
Download from Www.Somanuals.com. All Manuals Search And Download.
6. Plug the power cords into the power supplies and into separate power sources.
To provide redundancy, plug both power supplies into separate power sources. Note that the system can
operate with only one power connection, but there is no redundancy in this case.
When power is applied, the SP initializes and power supply LEDs illuminate. After a few minutes, the SP
login prompt appears on the terminal device. Note that the host is not initialized or powered on yet.
7. At the terminal device, log in to the SP as rootwith a password of changeme.
SUNSP00144FAC732F login: root
Password: changeme
. . .
->
After a brief delay, the SP prompt is displayed (->).
At this point, there are many commands you can perform using the Integrated Lights Out Manager interface.
For example, to create a user named admin, and to set the adminaccount role to Administratorand the
CLI mode to alom, enter:
-> create /SP/users/admin role=Administrator cli_mode=alom
Creating user...
Enter new password: ********
Enter new password again: ********
Created /SP/users/admin
Note that the asterisks in the example will not appear when you enter your password.
In the future, when you log in to the adminaccount, you use the ALOM CMT compatibility command set. In
the meantime, you are using the default ILOM command set.
Additional SP information, such as how to change the password and how to set up the SP network
parameters, is available in the online documentation set.
8. Power on the server and redirect the host output to display on the serial terminal device:
-> start /SYS
-> start /SP/console
Are you sure you want to start /SP/CONSOLE (y/n)? y
Serial console started. To stop, type #.
. . .
After you start the SP console, the server initialization takes approximately 20 minutes to complete.
9. When prompted, follow the onscreen instructions and enter the configuration information.
Refer to TABLE 1 for the list of configuration information and your entries. You will be prompted to confirm
the configuration several times, enabling confirmation and changes. If you are not sure how to respond to a
particular value, you can accept the default, and make future changes when the Solaris OS is running.
When the configuration menus are completed, the server reboots and displays the Solaris login prompt.
Download from Www.Somanuals.com. All Manuals Search And Download.
10. Log in to the server and explore the capabilities.
The following commands provide information about the system:
■
showrev– Displays the hostname and system architecture information. Use the -aoption with this
command to see the patches that are installed.
■
psrinfo– Displays information about the number and status of the processors and cores in the host.
Review the Solaris OS man pages and documentation for more details.
Accessing Important Information for SPARC Enterprise Series Servers
Before you deploy your server, check for the Product Notes for your server and other important information on
the following websites.
Global Site
North American Site
Japanese Site
Accessing Documentation
The following websites provide the latest versions of SPARC Enterprise Series manuals:
Global Site
North American Site
Japanese Site
Download from Www.Somanuals.com. All Manuals Search And Download.
Reader's Comments Regarding This Manual
If you have any comments or requests regarding this manual, or if you find any unclear statements in the
manual, please state your points specifically, and forward it to the system engineer (SE) in charge, or your sales
representative.
Copyright 2008 Sun Microsystems, Inc. All rights reserved. FUJITSU LIMITED provided technical input and review on portions of this material.
Copyright 2008 Sun Microsystems, Inc. Tous droits réservés. Entrée etrevue tecnical fournies par FUJITSU LIMITED sur des parties de ce matériel.
Manual Code C120-E518-01XA
Part No. 875-4395-10
May 2008, Revision A
Download from Www.Somanuals.com. All Manuals Search And Download.
Download from Www.Somanuals.com. All Manuals Search And Download.
Download from Www.Somanuals.com. All Manuals Search And Download.
Manual Code C120-E518-01XA
Part No. 875-4395-10
2008 年 5 月 , Revision A
Download from Www.Somanuals.com. All Manuals Search And Download.
|