Fujitsu Air Conditioner AOU18CL User Manual

OPERATING MANUAL  
MODE D’EMPLOI  
MANUAL DE FUNCIONAMIENTO  
Indoor Unit  
ASU18CL  
Outdoor Unit  
AOU18CL  
KEEP THIS OPERATION MANUAL  
FOR FUTURE REFERENCE  
P/N9315255020-01  
FUJITSU GENERAL LIMITED  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CONTENTS  
SAFETY PRECAUTIONS..................................... En-1  
FEATURES AND FUNCTIONS............................ En-2  
NAME OF PARTS ................................................ En-3  
PREPARATION .................................................... En-4  
OPERATION ........................................................ En-5  
TIMER OPERATION ............................................ En-7  
SLEEPTIMER OPERATION ................................. En-8  
ADJUSTINGTHE DIRECTION OF  
AIR CIRCULATION .............................................. En-9  
SWING OPERATION ......................................... En-10  
MANUAL AUTO OPERATION .......................... En-10  
CLEANING AND CARE ...................................... En-11  
TROUBLESHOOTING ....................................... En-13  
OPERATINGTIPS .............................................. En-14  
SAFETY PRECAUTIONS  
G Do not attempt to install this air conditioner by yourself.  
G This unit contains no user-serviceable parts. Always consult authorized service per-  
sonnel for repairs.  
DANGER!  
G When moving, consult authorized service personnel for disconnection and installa-  
tion of the unit.  
G Do not become excessively chilled by staying for lengthy periods in the direct cooling  
airflow.  
G Do not insert fingers or objects into the outlet port or intake grilles.  
G Do not start and stop air conditioner operation by disconnecting the power supply  
cord and so on.  
G Take care not to damage the power supply cord.  
G In the event of a malfunction (burning smell, etc.), immediately stop operation, dis-  
connect the power supply plug, and consult authorized service personnel.  
G If the power supply cord of this appliance is damaged, it should only be replaced by  
the authorized service personal, since special purpose tools and specified cord are  
required.  
G Provide occasional ventilation during use.  
CAUTION!  
G Do not direct air flow at fireplaces or heating apparatus.  
G Do not climb on, or place objects on, the air conditioner.  
G Do not hang objects from the indoor unit.  
G Do not set flower vases or water containers on top of air conditioners.  
G Do not expose the air conditioner directly to water.  
G Do not operate the air conditioner with wet hands.  
G Do not pull power supply cord.  
G Turn off power source when not using the unit for extended periods.  
G Check the condition of the installation stand for damage.  
G Do not place animals or plants in the direct path of the air flow.  
G Do not drink the water drained from the air conditioner.  
G Do not use in applications involving the storage of foods, plants or animals, precision  
equipment, or art works.  
G Do not apply any heavy pressure to radiator fins.  
G Operate only with air filters installed.  
G Do not block or cover the intake grille and outlet port.  
G Ensure that any electronic equipment is at least one metre away from either the in-  
door or outdoor units.  
G Avoid installing the air conditioner near a fireplace or other heating apparatus.  
G When installing the indoor and outdoor unit, take precautions to prevent access to  
infants.  
G Do not use inflammable gases near the air conditioner.  
En-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TYPE  
TYPE  
TIPO  
COOLING MODEL  
MODÈLE REFROIDISSANT  
MODELO DE REFRIGERACIÓN  
INDOOR UNIT  
MODEL  
ASU18CL  
AOU18CL  
UNIDAD INTERIOR  
UNITÉ INTÉRIEURE  
MODÈLE  
MODELO  
OUTDOOR UNIT  
UNIDAD EXTERIOR  
UNITÉ EXTÉRIEURE  
SPECIFICATIONS  
POWER SUPPLY ................................................................................................................................................... 208/230 V~60 Hz  
COOLING  
CAPACITY ..............................................................................................................................................................18,000 BTU/h  
INPUT POWER ................................................................................................................................................................1.73 kW  
CURRENT ............................................................................................................................................................................. 7.7 A  
FICHE TECHNIQUE  
ALIMENTATION.................................................................................................................................................... 208/230 V~60 Hz  
REFROIDISSEMENT  
PUISSANCE FRIGORIFIQUE ................................................................................................................................18.000 BTU/h  
PUISSANCE ABSORBÉE ............................................................................................................................................... 1,73 kW  
INTENSITÉ ........................................................................................................................................................................... 7,7 A  
ESPECIFICACIONES  
ALIMENTACIÓN ................................................................................................................................................... 208/230 V~60 Hz  
REFRIGERACIÓN  
CAPACIDAD...........................................................................................................................................................18.000 BTU/h  
ENTRADA DE ALIMENTACIÓN ..................................................................................................................................... 1,73 kW  
CORRIENTE .......................................................................................................................................................................... 7,7 A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Fig. 1  
Fig. 2  
Fig. 3  
Fig. 5  
Fig. 4  
Fig. 6  
Fig. 7  
To facilitate explanation, the accompanying illustra-  
tion has been drawn to show all possible indicators;  
in actral operation, however, the display will only  
show those indicators appropriate to the current op-  
eration.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FEATURES AND FUNCTIONS  
INVERTER  
REMOVABLE OPEN PANEL  
At the start of operation, a large power is used to bring the  
room quickly to the desired temperature. Afterwards, the  
unit automatically switches to a low power setting for eco-  
nomic and comfortable operation.  
The indoor units Open Panel can be removed for easy clean-  
ing and maintenance.  
MILDEW-RESISTANT FILTER  
AUTO CHANGEOVER  
The AIR FILTER has been treated to resist mildew growth,  
thus allowing cleaner use and easier care.  
The operation mode (cooling, dry) is switched automatically  
to maintain the set temperature, and the temperature is kept  
constant at all times.  
SUPER QUIET OPERATION  
When the FAN CONTROL button is used to select QUIET,  
the unit begins super-quiet operation; the indoor units air-  
flow is reduced to produce quieter operation.  
PROGRAM TIMER  
The program timer allows you to integrate OFF timer and  
ON timer operations in a single sequence. The sequence  
can involve one transition from OFF timer to ON timer, or  
from ON timer to OFF timer, within a twenty-four hour pe-  
riod.  
POLYPHENOL CATECHIN AIR CLEANING FILTER  
The polyphenol catechin air cleaning filter uses static elec-  
tricity to clean the air of fine particles and dust such as to-  
bacco smoke and plant pollen that are too small to see.  
The filter contains catechin, which is highly effective against  
various bacteria by suppressing the growth of the bacteria  
adsorbed by the filter.  
Note that when the air cleaning filter is installed, the amount  
of air produced decreases, causing a slight decrease in the  
air conditioner's performance.  
SLEEP TIMER  
When the SLEEP button is pressed during cooling mode,  
the thermostat setting is gradually raised during the period  
of operation. When the set time is reached, the unit auto-  
matically turns off.  
WIRELESS REMOTE CONTROL UNIT  
NEGATIVE AIR IONS DEODORIZING FILTER  
The Wireless Remote Control Unit allows convenient con-  
trol of air conditioner operation.  
It comprises pottery super micro particles, which can pro-  
duce negative air ions having the effect of deodorizing and  
can absorb and remit the peculiar smell at home.  
SWING OPERATION  
TheAir Flow Direction Louvers swings automatically up and  
down so that the air speeds to every nook and corner of  
your room.  
WIRED REMOTE CONTROL UNIT (OPTION)  
The optional wired remote control unit (model No.: UTB-UUB) can be used.  
When you use remote control unit, there are following different points as compared with using wireless remote control unit.  
[The additional functions for wired ones]  
• Weekly timer  
Temperature set back timer  
[The restricted functions for wired ones]  
• QUIET can't be selected in FAN MODE.  
• Sleep-timer can't be used.  
And you can't use both wired remote control unit and wireless simultaneously.  
(Only one kind can be selected)  
En-2  
05M150_9315255020-01_En  
2
2005.12.15, 10:56  
Download from Www.Somanuals.com. All Manuals Search And Download.  
NAME OF PARTS  
Fig. 1 Indoor Unit  
Fig. 6 Remote Control Unit  
1 Operating Control Panel (Fig. 2)  
2 MANUAL AUTO button  
J SLEEP button  
K MASTER CONTROL button  
When kept on pressing the MANUAL  
AUTO button for more than 10 seconds,  
the forced cooling operation will start.  
The forced cooling operation is used at the  
time of installation.  
Only for authorized service personnel's  
use.  
When the forced cooling operation starts  
by any chance, press the START/STOP but-  
ton to stop the operation.  
L SET TEMP. button (  
M Signal Transmitter  
N TIMER MODE button  
/
)
O TIMER SET (  
/
) button  
P FAN CONTROL button  
Q START/STOP button  
R SET button  
S SWING button  
T RESET button  
U TEST RUN button  
3 Indicator (Fig. 3)  
This button is used when installing the  
conditioner, and should not be used un-  
der normal conditions, as it will cause the  
air conditioners thermostat function to op-  
erate incorrectly.  
If this button is pressed during normal op-  
eration, the unit will switch to test opera-  
tion mode, and the Indoor Units OPERA-  
TION Indicator Lamp and TIMER Indicator  
Lamp will begin to flash simultaneously.  
To stop the test operation mode, press the  
START/STOP button to stop the air condi-  
tioner.  
4 Remote Control Signal Receiver  
5 OPERATION Indicator Lamp (red)  
6 TIMER Indicator Lamp (green)  
If the TIMER indicator lamp flashes when  
the timer is operating, it indicates that a  
fault has occurred with the timer setting  
(See Page 14 Auto Restart).  
7 SUPER QUIET Indicator Lamp (green)  
8 SWING Indicator Lamp (orange)  
9 Intake Grille (Fig. 4)  
0 Front Panel  
A Air Filter  
B Air Flow Direction Louver  
C Right-Left Louver  
(behind Air Flow Direction Louver)  
D Drain Hose  
V CLOCK ADJUST button  
W Remote Control Unit Display (Fig. 7)  
X Transmit Indicator  
Y Clock Display  
Z Operating Mode Display  
[ Timer Mode Display  
\ Fan Speed Display  
] Temperature SET Display  
` SLEEP Display  
E Air Cleaning Filter  
a SWING Display  
Fig. 5 Outdoor Unit  
F Pipe Unit  
G Drain port (bottom)  
H Intake Port  
I Outlet Port  
Refer to the folded out page on the cover.  
En-3  
05M150_9315255020-01_En  
3
2005.12.15, 10:56  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PREPARATION  
CAUTION!  
Turn on the Power  
Take care to prevent infants from  
accidentally swallowing batteries.  
When not using the Remote Control Unit  
for an extended period, remove the  
batteries to avoid possible leakage and  
damage to the unit.  
In the case of a direct line connection, turn on the cir-  
cuit breaker.  
1
If leaking battery fluid comes in contact  
with your skin, eyes, or mouth, immedi-  
ately wash with copious amounts of  
water, and consult your physician.  
Dead batteries should be removed  
immediately and disposed of properly,  
either in a battery collection receptacle  
or to the appropriate authority.  
Load Batteries (AAA/R03/LR03 × 2)  
Press and slide the battery compartment lid on the re-  
1
verse side to open it.  
Slide in the direction of the arrow while pressing the  
mark.  
Do not attempt to recharge dry batteries.  
Never mix new and used batteries, or  
batteries of different types.  
Insert batteries.  
Be sure to align the battery polarities (  
2
3
Batteries should last about one year  
under normal use. If the Remote Con-  
trol Units operating range becomes ap-  
preciably reduced, replace the batteries  
and press the RESET button with the tip  
of a ballpoint pen or other small object.  
) correctly.  
Close the battery compartment lid.  
Set the Current time  
Press the CLOCK ADJUST button (Fig. 6 V).  
1
2
Use the tip of a ball-point pen or other small object to press the button.  
Use the TIMER SET (  
/
) buttons (Fig. 6 O) to  
adjust the clock to the current time.  
button: Press to advance the time.  
button: Press to reverse the time.  
(Each time the buttons are pressed, the time will be advanced/reversed in  
one-minute increments; hold the buttons depressed to change the time  
quickly in ten-minute increments.)  
Press the CLOCK ADJUST button (Fig. 6 V) again.  
This completes the time setting and starts the clock.  
3
To Use the Remote Control Unit  
The Remote Control Unit must be pointed at signal receiver (Fig. 1 4) to operate  
correctly.  
Operating Range: About 7 meters.  
When a signal is properly received by the air conditioner, a beeping sound will  
be heard.  
If no beep is heard, press the Remote Control Unit button again.  
Remote Control Unit Holder  
Insert  
Slide up  
Pull out  
Press in  
Screws  
1
Mount the Holder.  
2
Set the Remote Control  
Unit.  
3
To remove the Remote  
Control Unit (when use at  
hand).  
En-4  
05M150_9315255020-01_En  
4
2005.12.15, 10:56  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPERATION  
To Select Mode Operation  
Press the START/STOP button (Fig.6 Q).  
1
2
The indoor units OPERATION Indicator Lamp (red) (Fig. 3 5) will light.  
The air conditioner will start operating.  
Press the MASTER CONTROL button (Fig.6 K) to se-  
lect the desired mode.  
Each time the button is pressed, the mode will change in the following  
order.  
s
s
s
s
AUTO  
COOL  
DRY  
FAN  
About three seconds later, the entire display will reappear.  
Example: When set to COOL.  
To Set the Thermostat  
Press the SET TEMP. button (Fig. 6 L).  
button: Press to raise the thermostat setting.  
button: Press to lower the thermostat setting.  
Thermostat setting range:  
AUTO .................................. 64°F to 88 °F  
Cooling/Dry ........................ 64°F to 88 °F  
The thermostat cannot be used to set room temperature during the FAN mode (the  
temperature will not appear on the Remote Control Units Display).  
About three seconds later, the entire display will reappear.  
The thermostat setting should be considered a standard value, and may differ  
somewhat from the actual room temperature.  
Example: When set to 80 °F.  
To Set the Fan Speed  
Press the FAN CONTROL button (Fig. 6 P).  
Each time the button is pressed, the fan speed changes in the following order:  
s
AUTO  
s
s
s
HIGH  
MED  
LOW  
s QUIET  
About three seconds later, the entire display will reappear.  
When set to AUTO:  
Cooling : As the room temperature approaches that of the thermostat setting,  
the fan speed becomes slower.  
Fan  
: The fan runs at the low fan speed.  
The fan will operate at a very low setting during Monitor operation.  
Example: When set to AUTO.  
SUPER QUIET Operation  
When set to QUIET:  
SUPER QUIET operation begins. SUPER QUIET Indicator Lamp (green) (Fig.3 7)  
will light.The indoor units airflow will be reduced for quieter operation.  
SUPER QUIET operation cannot be used during Dry mode. (The same is true  
when dry mode is selected during AUTO mode operation.)  
During Super Quiet operation, Cooling performance will be reduced somewhat.  
If the room does not cool down when using SUPER QUIET Operation, please  
adjust the air conditioners Fan Speed.  
En-5  
05M150_9315255020-01_En  
5
2005.12.15, 10:56  
Download from Www.Somanuals.com. All Manuals Search And Download.  
To Stop Operation  
Press the START/STOP button (Fig. 6 Q).  
The OPERATION Indicator Lamp (red) (Fig. 3 5) will go out.  
About AUTO CHANGEOVER Operation  
AUTO:  
When AUTO CHANGEOVER operation first selected, the fan will oper-  
ate at very low speed for about one minute, during which time the unit  
detects the room conditions and selects the proper operating mode.  
If the difference between the thermostat setting and actual room tem-  
perature is more than +4 °F Cooling or dry operation  
If the difference between the thermostat setting and actual room tem-  
perature is +4 °F or less Monitor operation  
When the thermostat setting of air conditioner has been adjusted to  
near the room temperature or the room temperature becomes lower  
than the thermostat setting, it will begin monitor operation. In the  
monitor operation mode, the fan will operate at low speed. If the room  
temperature subsequently changes, the air conditioner will once again  
select the appropriate operation (Cooling) to adjust the temperature to  
the value set in the thermostat.  
(The monitor operation range is in the temperature of +4 °F or less  
relative to the thermostat setting.)  
If the mode automatically selected by the unit is not what you wish,  
select one of the mode operation (COOL, DRY, FAN).  
About Mode Operation  
Cooling: Use to cool your room.  
During Cooling/Dry mode:  
Dry:  
Use for gently cooling while dehumidifying your room.  
Set the thermostat to a temperature set-  
ting that is lower than the current room  
temperature.The Cooling and Dry modes  
will not operate if the thermostat is set  
higher than the actual room temperature  
(in Cooling mode, the fan alone will oper-  
ate).  
You cannot heat the room during Dry mode.  
During Dry mode, the unit will operate at low speed; in order to adjust  
room humidity, the indoor units fan may stop from time to time. Also,  
the fan may operate at very low speed when adjusting room humidity.  
The fan speed cannot be changed manually when Dry mode has been  
selected.  
During Fan mode:  
You can not use the unit to cool your  
room.  
Fan:  
Use to circulate the air throughout your room.  
En-6  
05M150_9315255020-01_En  
6
2005.12.15, 10:56  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TIMER OPERATION  
Before using the timer function, be sure that the Remote Control Unit is set to the correct current time (P. 4).  
To Use the ON timer or OFF timer  
To Cancel the Timer  
Press the START/STOP button (Fig. 6 Q)  
(if the unit is already operating, proceed to step 2).  
The indoor units OPERATION Indicator Lamp (red) (Fig. 3 ) will light.  
1
Use the TIMER button to select “CANCEL”.  
The air conditioner will return to normal  
operation.  
5
To Change the Timer Settings  
Press the TIMER MODE button (Fig. 6 N) to select the  
OFF timer or ON timer operation.  
Each time the button is pressed the timer function changes in the follow-  
ing order:  
Perform steps 2 and 3.  
2
To Stop Air Conditioner Operation  
while the Timer is Operating  
Press the START/STOP button.  
s
s
s
ON  
CANCEL  
OFF  
To Change Operating Conditions  
If you wish to change operating conditions  
(Mode, Fan Speed, Thermostat Setting,  
SUPER QUIET mode), after making the  
timer setting wait until the entire display  
reappears, then press the appropriate  
buttons to change the operating condition  
desired.  
t
PROGRAM(OFF ON, OFF ON)  
The indoor units TIMER Indicator Lamp (green) (Fig. 3 6) will light.  
Use the TIMER SET buttons (Fig. 6 O) to adjust the  
3
desired OFF time or ON time.  
Set the time while the time display is flashing (the flashing will continue  
for about five seconds).  
button: Press to advance the time.  
button: Press to reverse the time.  
About five seconds later, the entire display will reappear.  
To Use the Program timer  
Press the START/STOP button (Fig. 6 Q).  
(if the unit is already operating, proceed to step 2).  
The indoor units OPERATION Indicator Lamp (red) (Fig. 3 5) will light.  
To Cancel the Timer  
1
Use the TIMER MODE button to select  
“CANCEL”.  
The air conditioner will return to normal  
operation.  
Set the desired times for OFF timer and ON timer.  
To Change the Timer Settings  
2
See the section “To Use the ON timer or OFF timer” to set the desired  
1. Follow the instructions given in the section  
To Use the ONTimer or OFFTimer” to se-  
lect the timer setting you wish to change.  
mode and times.  
About three seconds later, the entire display will reappear.  
The indoor unitsTIMER Indicator Lamp (green) (Fig. 3 6) will light.  
2. Press the TIMER MODE button to select  
either OFF  
ON or OFF  
ON.  
Press the TIMER MODE button (Fig. 6 N) to select the  
To Stop Air Conditioner Operation  
while the Timer is Operating  
3
PROGRAM timer operation (OFF  
will display).  
ON or OFF  
ON  
Press the START/STOP button.  
The display will alternately show “OFF timer” and “ON timer”, then change  
to show the time setting for the operation to occur first.  
To Change Operating Conditions  
If you wish to change operating conditions  
(Mode, Fan Speed, Thermostat Setting,  
SUPER QUIET mode), after making the timer  
setting wait until the entire display reap-  
pears, then press the appropriate buttons to  
change the operating condition desired.  
The program timer will begin operation. (If the ON timer has been se-  
lected to operate first, the unit will stop operating at this point.)  
About five seconds later, the entire display will reappear.  
About the Program timer  
The program timer allows you to integrate OFF timer and ON timer operations in  
a single sequence. The sequence can involve one transition from OFF timer to  
ON timer, or from ON timer to OFF timer, within a twenty-four hour period.  
The first timer function to operate will be the one set nearest to the current time.  
The order of operation is indicated by the arrow in the Remote Control Units  
Display (OFF ON, or OFF ON).  
One example of Program timer use might be to have the air conditioner auto-  
matically stop (OFF timer) after you go to sleep, then start (ON timer) automati-  
cally in the morning before you arise.  
En-7  
05M150_9315255020-01_En  
7
2005.12.15, 10:56  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SLEEP TIMER OPERATION  
Unlike other timer functions, the SLEEP timer is used to set the length of time until air conditioner operate is stopped.  
To Use the SLEEP Timer  
To Cancel the Timer:  
While the air conditioner is operating or stopped, press the  
SLEEP button (Fig. 6 J).  
The indoor units OPERATION Indicator Lamp (red) (Fig. 3 5) lights and theTIMER  
Use the TIMER MODE button to select  
“CANCEL”.  
The air conditioner will return to normal  
operation.  
Indicator Lamp (green) (Fig. 3 6) light.  
To Stop the Air Conditioner During  
Timer Operation:  
To Change the Timer Settings  
Press the START/STOP button.  
Press the SLEEP button (Fig. 6 J) once again and set the time  
using the TIMER SET (  
/
) buttons (Fig. 6 O).  
Set the time while the Timer Mode Display is flashing (the flashing will continue  
about five seconds).  
button: Press to advance the time.  
button: Press to reverse the time.  
About five seconds later, the entire display will reappear.  
About the SLEEP Timer  
To prevent excessive cooling during sleep, the SLEEP timer function automatically modifies the thermostat setting in accord-  
ance with the set time setting. When the set time has elapsed, the air conditioner completely stops.  
During Cooling/Dry operation:  
When the SLEEP timer is set, the thermostat setting is automatically raised 2 °F every sixty minutes.When the thermostat has  
been raised a total of 4 °F, the thermostat setting at that time is maintained until the set time has elapsed, at which time the air  
conditioner automatically turns off.  
SLEEP timer setting  
Set time  
1 hour  
4 °F  
2 °F  
En-8  
05M150_9315255020-01_En  
8
2005.12.15, 10:56  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ADJUSTING THE DIRECTION OF AIR CIRCULATION  
Vertical (up-down) direction of airflow is adjusted by pressing the Remote Control Units SET button. Horizontal (right-left)  
airflow direction is adjusted manually, by moving the Air Flow Direction Louvers.  
Whenever making horizontal airflow adjustments, start air conditioner operation and be sure that the vertical air direction  
louvers are stopped.  
R
Vertical Air Direction Adjustment  
DANGER!  
Never place fingers or foreign objects in-  
side the outlet ports, since the internal fan  
operates at high speed and could cause  
personal injury.  
Press the SET button (Fig. 6 R).  
Each time the button is pressed, the air direction range will change as follows:  
1
2
3
4
5
6
7
Always use the Remote Control Unit’s  
SET button to adjust the vertical airflow  
louvers. Attempting to move them  
manually could result in improper op-  
eration; in this case, stop operation and  
restart. The louvers should begin to  
operate properly again.  
Types of Air flow Direction Setting:  
1,2,3 During Cooling/Dry modes  
1,2,3,4,5,6,7 : During FAN mode  
:
The Remote Control Units display does  
not change.  
1
2
3
During use of the Cooling and Dry  
modes, do not set the Air Flow Direc-  
tion Louvers in the range 4 - 7 for  
long periods of time, since water vapor  
may condense near the outlet louvers  
and drops of water may drip from the  
air conditioner. During the Cooling and  
Dry modes, if the Air Flow Direction  
Louvers are left in the range 4 - 7 for  
more than 30 minutes, they will auto-  
matically return to position 3.  
4
5
6
7
Use the air direction adjustments within the ranges shown above.  
The vertical airflow direction is set automatically as shown, in accordance with  
the type of operation selected.  
During Cooling/Dry/FAN mode : Horizontal flow 1  
When used in a room with infants, chil-  
dren, elderly or sick persons, the air  
direction and room temperature  
should be considered carefully when  
making settings.  
During AUTO mode operation, for the first minute after beginning operation,  
airflow will be horizontal 1; the air direction cannot be adjusted during this pe-  
riod.  
Right-Left Adjustment  
R
DANGER!  
Adjust the Right-Left louvers.  
Move the Right-Left louvers to adjust air flow in the direction you prefer.  
When adjusting the Right-Left Louvers, it  
is necessary to stop the Air-Conditioner  
first and make sure that it stops completely  
before adjusting the direction.  
Right-Left Louvers  
knob  
knob(three places)  
En-9  
05M150_9315255020-01_En  
9
2005.12.15, 10:56  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SWING OPERATION  
Begin air conditioner operation before performing this procedure.  
To select SWING Operation  
Press the SWING button (Fig. 6 S).  
The SWING Display (Fig. 7 a) will light.  
In this mode, the Air Flow Direction Louvers will swing automatically to direct the  
air flow both up and down.  
To stop SWING Operation  
Press the SWING button (Fig. 6 S) once again.  
The SWING Display (Fig. 7 a) will go out.  
Airflow direction will return to the setting before swing was begun.  
About Swing Operation  
During cooling/Dry mode : Swings between 1 and 3.  
During fan mode  
: • Air flow Direction setting 1,2,3.  
Swings between 1 and 3.  
• Air flow Direction setting 4,5,6,7.  
Swings between 3 and 7.  
The SWING operation may stop temporarily when the air conditioners fan is not  
operating, or when operating at very low speeds.  
MANUAL AUTO OPERATION  
Use the MANUAL AUTO operation in the event the Remote Control Unit is lost or otherwise unavailable.  
How To Use the Main Unit Controls  
When the air conditioner is operated  
with the controls on the Main Unit, it  
will operate under the same mode as  
the AUTO mode selected on the Re-  
mote Control Unit (see page 6).  
Press the MANUAL AUTO button (Fig. 2 2) on the main unit  
control panel.  
To stop operation, press the MANUAL AUTO button (Fig. 2 2) once again.  
The fan speed selected will be “AUTO”  
and the thermostat setting will be  
standard.(76°F)  
(Controls are located inside the Open Panel)  
En-10  
05M150_9315255020-01_En  
10  
2005.12.15, 10:56  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CLEANING AND CARE  
Before cleaning the air conditioner, be sure to turn it off and disconnect the Power.  
CAUTION!  
Be sure the Intake Grille (Fig. 1 9) is installed securely.  
When removing and replacing the air filters, be sure not to touch the heat exchanger, as per-  
sonal injury may result.  
Cleaning the Intake Grille  
1. Remove the Intake Grille.  
Cleaning the Air Filter  
1. Open the Intake Grille, and remove the air  
1 Place your fingers at both lower ends of the grille  
panel, and lift forward; if the grille seems to catch  
partway through its movement, continue lifting up-  
ward to remove.  
filter.  
Lift up the air filters handle, disconnect the two lower  
tabs, and pull out.  
Air filter handle  
2 Pull past the intermediate catch and open the Intake  
Grille wide so that it become horizontal.  
Intake Grille  
2
Hooks (two places)  
2
1
2. Remove dust with a vacuum cleaner or by  
1
washing.  
Intake Grille  
After washing, allow to dry thoroughly in a shaded place.  
3. Replace the Air Filter and close the Intake  
Grille.  
Mounting  
shaft  
1 Align the sides of the air filter with the panel, and push  
in fully, making sure the two lower tabs are returned  
properly to their holes in the panel.  
Knob  
2. Clean with water.  
Remove dust with a vacuum cleaner; wipe the unit with  
warm water, then dry with a clean, soft cloth.  
3. Replace the Intake Grille.  
Hooks (two places)  
2 Close the Intake Grille.  
1 Pull the knobs all the way.  
(For purposes of example, the illustration shows the unit  
without Intake Grille installed.)  
2 Hold the grille horizontal and set the left and right  
mounting shafts into the bearings at the top of the  
panel.  
Dust can be cleaned from the air filter either with a vacuum  
cleaner, or by washing the filter in a solution of mild de-  
tergent and warm water. If you wash the filter, be sure to  
allow it to dry thoroughly in a shady place before rein-  
stalling.  
3 Press the place where the arrow on the diagram indi-  
cates and close the Intake Grille.  
Mounting shaft  
Intake  
Grille  
Bearing  
Knob  
2
If dirt is allowed to accumulate on the air filter, air flow  
will be reduced, lowering operating efficiency and increas-  
ing noise.  
1
During periods of normal use, the Air Filters should be  
cleaned every two weeks.  
Intake Grille  
Mounting  
shaft  
Knob  
When used for extended periods, the unit may accumulate dirt inside, reducing its performance.We recommend that the  
unit be inspected regularly, in addition to your own cleaning and care. For more information, consult authorized service  
personnel.  
When cleaning the units body, do not use water hotter than 104 °F, harsh abrasive cleansers, or volatile agents like  
benzene or thinner.  
Do not expose the unit body to liquid insecticides or hairsprays.  
When shutting down the unit for one month or more, first allow the fan mode to operate continuously for about one-half  
day to allow internal parts to dry thoroughly.  
En-11  
05M150_9315255020-01_En  
11  
2005.12.15, 10:56  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CLEANING AND CARE  
Air Cleaning Filter Installation  
Replacing dirty Air cleaning filters  
Replace filters with the following components (purchased  
separately).  
1. Open the Intake Grille and remove the Air  
filters.  
POLYPHENOL CATECHIN AIR CLEANING FILTER : UTR-FA03-2  
Negative air ions deodorizing filter: UTR-FA03-3  
1. Open the Intake Grille and remove the Air  
filters.  
Air Filter  
(Right & Left)  
Air Filter  
(Right & Left)  
2. Install the Air cleaning filter set (set of 2).  
1 Set the air cleaning filter into the air cleaning filter  
frame.  
2. Replace them by two new Air cleaning  
filters.  
Air cleaning filter set  
1 Remove the old air cleaning filters in reverse order of  
Air cleaning filter frame  
their installation.  
2 Install in the same way as for installation of the air  
cleaning filter set.  
Air cleaning filter  
3. Install the two Air filters and close the  
Intake Grille.  
2 Engage the latch at both ends of the filter with the  
two hooks at the rear of the air cleaning filter frame.  
Hook (2 places at the rear)  
Air Filter(Right & Left)  
In regard to the Air Cleaning Filters  
POLYPHENOL CATECHIN AIR CLEANING FILTER (one sheet)  
The Air Cleaning Filters are disposable filters. (They can  
not be washed and reused.)  
For storage of the Air Cleaning Filters, use the filters as  
soon as possible after the package has been opened.  
(The air cleaning effect decreases when the filters are left  
in the opened package)  
Latch (2 places)  
Take care that the air cleaning filter does not project be-  
yond the frame.  
3 Engage the four fixing locations at the top and bot-  
tom of the air cleaning filter frame with the hooks of  
the air filter.  
Generally, the filters should be exchanged about every  
three months.  
Please buy delicated air cleaning filters (UTR-FA03-2) (Sold  
separately) to exchange the used dirty air cleaning filters.  
Rear of the filter  
[Negative air ions deodorizing filter (one sheet) — light blue]  
The filters should be exchanged about every three years  
so as to maintain the deodorizing effect.  
Fixing location, hook (4 places)  
Filter frame is not a one-off product.  
Please buy delicated deodorizing filter (UTR-FA03-3) (Sold  
separately) when exchanging the filters.  
3. Install the two Air filters and close the  
Intake Grille.  
Maintenance of Deodorizing Filters  
Air Filter  
(Right & Left)  
In order to maintain the deodorizing effect, please clean the  
filter in the follow way once three months.  
1 Remove the deodorizing filter.  
2 Clean with water and dry in the air.  
1) Flush the filters with high-pressure hot water until  
the surface of the filters are covered with water.  
Please flush with diluent neutral detergent.  
Never wash by reaming or rubbing, otherwise it  
will damage the deodorizing effect.  
When air cleaning filters are used, the effect will increased  
by setting the fan speed to “High”.  
2) Rinse with water flow.  
3) Dry in shade.  
3 Reinstall the deodorizing filter.  
En-12  
05M150_9315255020-01_En  
12  
2005.12.15, 10:56  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TROUBLESHOOTING  
In the event of a malfunction (burning smell, etc.), immediately stop operation, disconnect the  
Power Supply Plug, and consult authorized service personnel.  
WARNING!  
Merely turning off the units power switch will not completely disconnect the unit from the power  
source. Always be sure to disconnect the Power Supply Plug or turn off your circuit breaker to  
ensure that power is completely off.  
Before requesting service, perform the following checks:  
Symptom  
Problem  
See Page  
NORMAL  
FUNCTION  
Doesn’t operate immedi-  
ately:  
If the unit is stopped and then immediately started again, the com-  
pressor will not operate for about 3 minutes, in order to prevent  
fuse blowouts.  
Whenever the Power Supply Plug is disconnected and then re-  
connected to a power outlet, the protection circuit will operate for  
about 3 minutes, preventing unit operation during that period.  
Noise is heard:  
During operation and immediately after stopping the unit, the  
sound of water flowing in the air conditioners piping may be  
heard. Also, noise may be particularly noticeable for about 2 to 3  
minutes after starting operation (sound of coolant flowing).  
During operation, a slight squeaking sound may be heard. This is  
the result of minute expansion and contraction of the front cover  
due to temperature changes.  
Smells:  
Some smell may be emitted from the indoor unit. This smell is  
the result of room smells (furniture, tobacco, etc.) which have  
been taken into the air conditioner.  
Mist or steam are  
emitted:  
During Cooling or Dry operation, a thin mist may be seen emitted  
from the indoor unit. This results from the sudden Cooling of  
room air by the air emitted from the air conditioner, resulting in  
condensation and misting.  
Airflow is weak or stops:  
The fan may operate at very low speed during Dry operation or  
when the unit is monitoring the rooms temperature.  
5
5
5
During SUPER QUIET operation, the fan will operate at very low  
speed.  
In the monitor AUTO operation, the fan will operate at very low  
speed.  
En-13  
05M150_9315255020-01_En  
13  
2005.12.15, 10:56  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TROUBLESHOOTING  
Items to check  
Symptom  
See Page  
Is the Power Supply Plug disconnected its outlet?  
Has there been a power failure?  
CHECK ONCE Doesn’t operate at all:  
MORE  
Has a fuse blown out, or a circuit breaker been tripped?  
Is the timer operating?  
7 - 8  
Is the Air Filter dirty?  
Air the air conditioners intake grille or outlet port blocked?  
Poor Cooling performance:  
Did you adjust the room temperature settings (thermostat) cor-  
rectly?  
Is there a window or door open?  
In the case of Cooling operation, is a window allowing bright sun-  
light to enter? (Close the curtains.)  
In the case of Cooling operation, are there heating apparatus and  
computers inside the room, or are there too many people in the  
room?  
Is the unit set for SUPER QUIET operation?  
5
4
The unit operates  
differently from the Remote  
Control Unit’s setting:  
Are the Remote Control Units batteries dead?  
Are the Remote Control Units batteries loaded properly?  
If the problem persists after performing these checks, or if you notice burning smells, or theTIMER Indicator Lamp (Fig. 3 6)  
and the OPERATION Indicator Lamp (Fig. 3 5) flashes, immediately stop operation, disconnect the Power Supply Plug, and  
consult authorized service personnel.  
OPERATING TIPS  
AUTO Restart  
In Event of Power Interruption  
If a power failure occurs during TIMER operation, the timer  
will be reset and the unit will begin (or stop) operation at the  
new time setting. In the event that this kind of timer fault  
occurs the TIMER Indicator Lamp will flash (see Page. 3).  
The air conditioner power has been interrupted by a  
power failure. The air conditioner will then restart auto-  
matically in its previous mode when the power is restored.  
Operated by setting before the power failure.  
Use of other electrical appliances (electric shaver, etc.) or  
nearby use of a wireless radio transmitter may cause the  
air conditioner to malfunction. In this event, temporarily  
disconnect the Power Supply Plug, reconnect it, and then  
use the Remote Control Unit to resume operation.  
En-14  
05M150_9315255020-01_En  
14  
2005.12.15, 10:56  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPERATING TIPS  
Temperature and Humidity Range  
Cooling Mode  
Dry Mode  
Outdoor temperature  
Indoor temperature  
About 14 °F to 115 °F  
About 64 °F to 90 °F  
About 14 °F to 115 °F  
About 64 °F to 90 °F  
If the air conditioner is used under higher temperature conditioner than those listed, the built-in protection circuit may  
operate to prevent internal circuit damage. Also, during Cooling and Dry modes, if the unit is used under conditions of  
lower temperature than those listed above, the heat-exchanger may freeze, leading to water leakage and other damage.  
Do not use this unit for any purposes other than the Cooling, Dehumidifying, and air-circulation of rooms in ordinary  
dwellings.  
If the unit is used for long periods under high-humidity conditions, condensation may form on the surface of the indoor  
unit, and drip onto the floor or other objects underneath. (About 80% or more)  
Tips for saving energy  
When the outdoor temperature is low (about 50 °F or less), the unit will consume the power of 20~40W unless the power  
plug is disconnected from the outlet even if the air conditioner turns off.  
Remove the power plug to stop the power supply for energy saving when not using for a long time.  
En-15  
05M150_9315255020-01_En  
15  
2005.12.15, 10:56  
Download from Www.Somanuals.com. All Manuals Search And Download.  
05M150_9315255020-01_En  
16  
2005.12.15, 10:56  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Elation Professional Work Light 5 90 User Manual
Estate Clothes Dryer EED4100S User Manual
Exido Vacuum Cleaner 240 112 User Manual
Exmark Lawn Mower 4500 501 Rev A User Manual
Extron electronic Stereo Amplifier ASA 204 User Manual
Firstech LLC Automobile Electronics FT MBKG20 HRN User Manual
Frigidaire Dishwasher FDB956RB User Manual
Frymaster Fryer 45 y User Manual
Fujitsu Laptop P 1032 User Manual
GE Telephone 16258160 User Manual