Frymaster, a member of the Commercial Food Equipment Service Association, recommends
using CFESA Certified Technicians.
JUNE 2007
24-Hour Service Hotline 1-800-551-8633
` 8 1 9 6 3 2 5 ~
Download from Www.Somanuals.com. All Manuals Search And Download.
NOTICE:
If this filter unit is cleaned with water, disconnect the unit from power source before
cleaning and thoroughly dry the filter unit before reconnecting to electrical power
source.
DANGER
The optional crumb tray (if equipped) in portable filter systems must be emptied into a
fireproof container at the end of frying operations each day. Some food particles can
spontaneously combust if left soaking in certain shortening material.
NOTICE:
Drawings and photos used in this manual are intended to illustrate operational, cleaning
and technical procedures and may not conform to on-site management operational
procedures.
NOTICE
IF, DURING THE WARRANTY PERIOD, THE CUSTOMER USES A PART FOR THIS
ENODIS EQUIPMENT OTHER THAN AN UNMODIFIED NEW OR RECYCLED PART
PURCHASED DIRECTLY FROM FRYMASTER/DEAN, OR ANY OF ITS AUTHORIZED
SERVICE CENTERS, AND/OR THE PART BEING USED IS MODIFIED FROM ITS
ORIGINAL CONFIGURATION, THIS WARRANTY WILL BE VOID. FURTHER,
FRYMASTER/DEAN AND ITS AFFILIATES WILL NOT BE LIABLE FOR ANY CLAIMS,
DAMAGES OR EXPENSES INCURRED BY THE CUSTOMER WHICH ARISE DIRECTLY
OR INDIRECTLY, IN WHOLE OR IN PART, DUE TO THE INSTALLATION OF ANY
MODIFIED PART AND/OR PART RECEIVED FROM AN UNAUTHORIZED SERVICE
CENTER.
Download from Www.Somanuals.com. All Manuals Search And Download.
YPF95 Series Portable Filtration Systems
Installation & Operation Manual
TABLE OF CONTENTS
Page #
1-1
1.
2.
3.
4.
5.
6.
7.
INTRODUCTION
IMPORTANT INFORMATION
INSTALLATION INSTRUCTIONS
FILTER OPERATION
2-1
3-1
4-1
CLEANING AND MAINTENANCE
TROUBLESHOOTING
5-1
6-1
PARTS LIST
7-1
Download from Www.Somanuals.com. All Manuals Search And Download.
YPF95 SERIES PORTABLE FILTRATION SYSTEMS
CHAPTER 1: INTRODUCTION
1.1 Parts Ordering/Service Information
Place parts orders directly with your local Frymaster/Dean Factory Authorized Service Center. A
list of FASCs was included with the filter when shipped from the factory. If you do not have access
to this list, please contact the Frymaster/Dean service department at 1-800-551-8633 or 1-318-865-
To help speed your order, the following information is required:
Model Number
Serial Number
Optional Features
Type
Item Part Number
Quantity Needed
1.2 Service Information
Call the 1-800-551-8633 or (318) 865-1711 Service Hotline number for the location of your nearest
Factory Authorized Service Center. Always give the model and serial numbers of your filter unit.
Also, identify if your unit is supplied with or without a heater.
To assist you more efficiently, the following information will be needed:
Model Number
Serial Number
Type
Optional Features
Nature of Problem:
Additional information (i.e. oil temperature at filter time, time of day and other pertinent
information) may be helpful in solving your service problem.
1-1
Download from Www.Somanuals.com. All Manuals Search And Download.
YPF95 SERIES PORTABLE FILTRATION SYSTEMS
CHAPTER 1: INTRODUCTION
1.3 After Purchase
In order to improve service, have the following chart filled in by the Dean Authorized Service
Technician who installed this equipment.
Authorized Service
Technician/FASC
Address
Telephone/Fax
Model Number
Serial Number
1.4 Safety Information
Before attempting to operate your unit, read the instructions in this manual thoroughly.
Throughout this manual, you will find notations enclosed in double-bordered boxes similar to the
ones below.
CAUTION
CAUTION boxes contain information about actions or conditions that may cause or result in a
malfunction of your system.
WARNING
WARNING boxes contain information about actions or conditions that may cause or result in
damage to your system, and which may cause your system to malfunction.
DANGER
DANGER boxes contain information about actions or conditions that may cause or result in injury
to personnel, and which may cause damage to your system and/or cause your system to malfunction.
1-2
Download from Www.Somanuals.com. All Manuals Search And Download.
YPF95 SERIES PORTABLE FILTRATION SYSTEMS
CHAPTER 1: INTRODUCTION
1.5 Service Personnel Definitions
A. Qualified and/or Authorized Operating Personnel
Qualified/authorized operating personnel are those who have carefully read the information
in this manual and have familiarized themselves with the equipment functions, or have had
previous experience with the operation of equipment covered in this manual.
B. Qualified Installation Personnel
Qualified installation personnel are individuals, firms, corporations, or companies that are
responsible for the installation of electrical appliances, either in person or through a
representative. Qualified personnel must be experienced in such work, be familiar with all
electrical precautions involved, and have complied with all requirements of applicable
national and local codes.
C. Qualified Service Personnel
Qualified service personnel are those who are familiar with Frymaster/Dean equipment and
have been authorized by Frymaster/Dean to perform service on Frymaster/Dean equipment.
All authorized service personnel are required to be equipped with a complete set of service
parts manuals and stock a minimum amount of parts for Frymaster/Dean equipment. A list
of Frymaster/Dean Factory Authorized Service Centers (FASCs) was included with the fryer
when shipped from the factory. Failure to use qualified service personnel will void the
Frymaster/Dean warranty on your equipment.
1-3
Download from Www.Somanuals.com. All Manuals Search And Download.
YPF95 SERIES PORTABLE FILTRATION SYSTEMS
CHAPTER 2: IMPORTANT INFORMATION
2.1 General
YPF95 portable filters can be used with a variety of Frymaster fryers, as well as other
manufacturers’ equipment. Oil capacity is approximately 105 pounds. Unit specifications are listed
below.
Model
Unit Height Unit Width
Unit Length
(inches)
Tank Height Oil Capacity
(inches)
(inches)
(inches)
(pounds)
YPF95
53
18
33 ¼
9
105
YPF95 Series filter unit dimensions (unit and tank heights are measured from
bottom of casters to top of unit and tank, respectively).
2-1
Download from Www.Somanuals.com. All Manuals Search And Download.
YPF95 SERIES PORTABLE FILTRATION SYSTEMS
CHAPTER 2: IMPORTANT INFORMATION
2.1 General (cont.)
Oil or shortening is gravity-drained from the fryer into the filter, and then filtered through filter
paper. Filter powder, which enhances the filtering process, is distributed over the paper prior to
filtering.
All units are shipped completely assembled with accessories packed inside the filter pan. All units
are adjusted, tested and inspected at the factory before shipment.
WARNING
The on-site supervisor is responsible for ensuring that operators are made aware of
the inherent dangers of operating a hot oil filter system, particularly the aspects of
oil filtration, and draining/cleaning procedures.
An ON/OFF switch activates/deactivates the
filter pump, and a 7-amp (120V), or 5-amp
(230V) circuit breaker switches the power OFF if
an overload occurs. An internal backup thermal-
overload switch on the pump-motor provides
additional protection.
NOTE: If the circuit breaker is triggered,
depress the reset button to activate the
circuit after the failure has been
detected and repaired.
2.2 Rating Plate
Information on the rating plate includes model and serial numbers, as well as electrical requirements.
The rating plate is located on the back housing, near the electrical receptacle. Have the rating plate
information handy when communicating with the factory about a unit or requesting special parts or
information. Without rating plate information, proper identification of the unit cannot be confirmed.
2-2
Download from Www.Somanuals.com. All Manuals Search And Download.
YPF95 SERIES PORTABLE FILTRATION SYSTEMS
CHAPTER 2: IMPORTANT INFORMATION
2.3 Pre-Installation
NOTE: Failure to use qualified service personnel will void the Frymaster/Dean warranty.
A. Standards: Use of this filter unit must be in accordance with all applicable state and local
codes.
B. Electrical Connections: Domestic YPF95 filter units require a 115V 60 Hz., 15 amp
electrical supply. International/CE units require 230V 50 Hz., 7 amp electrical supply. Units
are equipped with a grounded male receptacle for use with a 16-3 SJT power cord set. If an
extension cord is required, it must be a three-conductor, grounded power cord of at least 16
gauge.
2.4 Unpacking the Filter System
Ensure the container is upright. Unpack the filter carefully and remove all accessories from the
carton. Do not discard or misplace parts and/or accessories; they will be needed for filter setup
and operation. Any accessories or starter kits included with the unit will be packaged inside
the filter tank.
After unpacking, immediately check the equipment for visible signs of shipping damage. If
such damage has occurred, contact the carrier and file the appropriate freight claims. Do not
contact the factory, as the responsibility of shipping damage is between the carrier and dealer
or end-user.
If your equipment arrives damaged:
a. File claim for damages immediately – Regardless of extent of damage.
b. Visible loss or damage – Be sure this is noted on the freight bill or express receipt and is
signed by the person making the delivery.
c. Concealed loss or damage – If damage is unnoticed until equipment is unpacked, notify
freight company or carrier immediately, and file a concealed damage claim. This should be
done within 15 days of date of delivery. Retain the shipping container for inspection.
NOTE: Frymaster does not assume responsibility for damage or loss incurred in transit.
2-3
Download from Www.Somanuals.com. All Manuals Search And Download.
YPF95LP SERIES PORTABLE FILTRATION SYSTEMS
CHAPTER 3: FILTER PREPARATION
3.1 Assembling The Filter System
On initial installation and before each use, remove all loose parts from the filter, wash the filter pan
and all accessories in hot, soapy water and dry thoroughly.
WARNING!
Water or boil-out solution MUST not be allowed to drain into the filter pan or filter
system. Irreversible damage will result if water is allowed into the system, and the
warranty will be voided.
YPF95 Series portable filtration systems use a filter support grid, one sheet of filter paper and a
hold-down ring to secure the filter paper in place.
2
1
3
See illustration for proper assembly.
4
5
1. Filter Pan Cover Front
2. Filter Pan Cover Rear
3. Hold-Down Ring
4. Filter Paper (one sheet)
5. Screen/Sana Grid
6. Filter Pan Assembly
6
A. First, place the Sana Grid in the bottom of filter pan.
B. Place one sheet of filter paper on top of the Sana Grid. Ensure the paper evenly covers the filter
pan bottom.
C. Position the hold-down ring on top of the filter paper securely against the filter pan bottom,
forming a tight seal.
D. Sprinkle 8 ounces of filter powder over the filter paper, distributing the powder as evenly as
possible. If filtering a second frypot immediately after the first, add only 4 ounces of filter
powder for the second filtering.
E. Place filter pan covers onto the filter pan assembly.
F. Position filter in the space between the two fryers. Lock the rear casters to prevent filter from
moving out of position during the filtering process.
3-1
Download from Www.Somanuals.com. All Manuals Search And Download.
YPF95 SERIES PORTABLE FILTRATION SYSTEMS
CHAPTER 3: FILTER PREPARATION
-A-
YPF95 portable filter positioned correctly between two fryers with rear
casters locked in place.
G. Align the drain pipes over the front filter pan cover. Remove the front cover and replace it with
the oil baffle (as shown below). The baffle should sit on the hold-down ring inside the filter pan
and will prevent splashing during filtration.
2
1
4
3
4
Remove the front filter pan cover and insert
the oil baffle to prevent splashing and
movement during filtering. The oil baffle fits
straight down over the two drain tubes and
rests on the hold-down ring frame.
1. Oil Baffle (remove front lid)
2. Filter Pan Cover, Rear
3. Filter Pan
4. Drain Tube (fryer to filter)
3-2
Download from Www.Somanuals.com. All Manuals Search And Download.
YPF95 SERIES PORTABLE FILTRATION SYSTEMS
CHAPTER 4: FILTER OPERATION
4.1 General
YPF95 Series portable filters are designed to operate primarily as an independent filter unit.
Operations always start by ensuring the unit is properly plugged in and situated in the filter space
between the fryers. The general layout of a YPF95 Series portable filter with major components
identified is illustrated below.
Arrows indicate direction of oil flow during the filtration process.
4-1
Download from Www.Somanuals.com. All Manuals Search And Download.
YPF95 SERIES PORTABLE FILTRATION SYSTEMS
CHAPTER 4: FILTER OPERATION
4.2 Filtering Tools
These tools are not required, but are recommended to make the filtering task easier.
A. Measuring Cup: Used to measure eight ounces by volume of filter powder.
B. Scrub Brush: To clean sediment and residue from the filter pan and frypot.
C. Appropriate Clothing.
4.3 Filter Preparation
1. Ensure the YPF95 portable filter is positioned between fryer(s) it is being used to filter. The
casters must be locked in place and the faucet must be over an appropriate frypot. Remove
the front filter pan lid and place the oil baffle over the drain pipes and into the uncovered
portion of the filter.
2. Ensure the filter power switch is in "OFF" position prior to connecting to power supply.
3. Plug power cord into electrical outlet. The filter unit is ready for filtering. After filtering,
follow instructions in Section 4.4, Changing Filter Paper.
DANGER
The crumb tray (if equipped) in portable filter systems must be emptied into a
fireproof container at the end of frying operations each day. Some food particles
can spontaneously combust if left soaking in certain shortening material.
4.4 Changing Filter Paper
Filter paper should be replaced after each filter session, and most certainly at the beginning of each
workday. If filter paper is replaced once per day, excess sediment should be scraped from the filter
paper after each frypot is filtered (see photo). Use care not to tear the paper when scraping off
sediment. Filter at closing if possible. This ensures the oil is at proper filtering temperature.
Note: If filtering at closing, remove and discard the used filter paper in a fireproof container when filter
operations are complete. Wash all components in soapy water and dry completely.
Remove and replace the paper as follows:
1. Remove filter covers and/or oil baffle and move the filter away from the fryers and into an
open area.
2. Lift the hold down ring out of the filter pan.
3. Roll both ends of the filter paper into the center, ensuring no sediment falls out, and discard.
4-2
Download from Www.Somanuals.com. All Manuals Search And Download.
YPF95 SERIES PORTABLE FILTRATION SYSTEMS
CHAPTER 4: FILTER OPERATION
4.4 Changing Filter Paper (cont.)
4. Remove and check the Sana Grid for cleanliness and clean if necessary.
5. Check the filter-pan for cleanliness and clean if necessary; check the drain ports at the
bottom rear of the filter pan and clear any solidified shortening from the opening (black
arrow).
6. Replace the Sana Grid and place a new sheet of filter paper on top of the screen.
7. Replace the hold-down ring in the filter pan on top of the filter paper.
8. Measure 8 ounces of filter powder and distribute evenly over the surface of the paper.
9. Replace the filter pan covers and slide it back into place between the appropriate fryers. Plug
in the filter. It is now ready for operation.
Filter assembly.
4.5 Unit Operation
When filtering, follow these steps:
1. Follow the appropriate instructions in Sections 4.3 and 4.4 to prepare the filter unit for
operation.
2. Position the oil baffle over the drain pipes extending from the side of each fryer. It should sit
on the hold down ring in the bottom of the filter pan.
3. Turn the fryer main power switch to the "OFF" position.
4-3
Download from Www.Somanuals.com. All Manuals Search And Download.
YPF95 SERIES PORTABLE FILTRATION SYSTEMS
CHAPTER 4: FILTER OPERATION
4.5 Unit Operation (cont.)
DANGER
Do not leave filter unit unattended during the filtering operation.
Avoid spilling hot oil onto floor surfaces. When draining fryer into filter, never
exceed the maximum capacity of the filter pan.
DANGER
The oil temperature of the fryer to be filtered should be approximately 350°F (175°C).
Position drain handles properly prior to operating the filter unit. Failure to do this
can result in burn injury to the user.
4. Open the drain valve and allow the frypot oil to drain into the filter pan.
5. Ensure that the YPF95 filter faucet is located over the correct frypot. Turn the filter switch "ON" to
begin pumping filtered oil back into the fryer. Allow the oil to recycle through the fryer for a few
seconds to wash out sediment on the bottom of the frypot before closing the drain valve.
NOTE: The oil return wand can also be mounted in the wand holster inside the pan, for extended filtering
periods (polishing) prior to refilling frypot. NEVER LEAVE THE FILTER SYSTEM UNATTENDED WHILE
FILTERING!
6. When filtering is complete, close the drain valve handle. It takes approximately 5 to 7 minutes
for the filter to pump all the oil back into the fryer.
7. Before shutting off the filter, allow the pump to run for 10-15 seconds after air starts to sputter
through the faucet. Clearing residual shortening or oil from the return lines reduces the
likelihood of clogged lines.
NOTE: After filtering, scrape off debris and sediment accumulated on the filter paper and discard into a
fireproof container.
CAUTION
If using solid shortening, the return hose must be completely drained after filtering,
or the shortening will solidify and plug the hose or oil return lines as it cools.
NOTE: If filtration operations problems are encountered during use, please refer to Chapter 6 in this
manual.
4-4
Download from Www.Somanuals.com. All Manuals Search And Download.
YPF95 SERIES PORTABLE FILTRATION SYSTEMS
CHAPTER 5: PREVENTATIVE MAINTENANCE
5.1 General
Cleaning operations fall into three general categories:
• Wiping unit clean, interior and exterior, after each filter session.
• Cleaning, changing filter paper and preparing the unit for the next day’s business.
• Weekly cleaning to remove oil deposits and other particles that were previously missed.
WARNING
Do not use water jets to clean this equipment. To do so will damage the unit and void
the warranty.
WARNING
Never operate the filter unit unless cooking oil is at operating temperature.
5.2 Each Filter Use
Each time the portable filter is used:
• Wash down the insides of the filter pan with hot oil during the filtering process. DO NOT
allow excessive residue buildup to occur inside the filter pan.
• Change filter paper after each filter session or at the end of the day. Scrape sediment from
filter paper after each frypot is filtered within a filter session. Do not filter more than three
fryers per one sheet of filter paper.
• Wipe up any oil which may have splashed or spilled.
• Wipe all exterior surfaces of the filter unit.
WARNING
Do not run water or boil-out solution through the portable filter. Doing so will cause
irreparable damage to the pump, and void the warranty.
5-1
Download from Www.Somanuals.com. All Manuals Search And Download.
YPF95 SERIES PORTABLE FILTRATION SYSTEMS
CHAPTER 5: PREVENTATIVE MAINTENANCE
5.3 Daily: Close Of Business
At the close of a working day, filter the oil in all fryers. When the last fryer is finished, follow these
steps:
1. Ensure the flexible hose and pump lines are clear by running the filter pump for an
additional 10–15 seconds after the faucet begins to bubble.
2. Discard the filter paper in a fireproof container after use.
3. Remove the filter pan cover and hold-down ring assembly, and then remove the filter paper
and Sana Grid.
4. Wash all filter components with soapy water and rinse.
5. Dry all filter parts and the filter pan thoroughly before reassembling.
6. Check all fittings on the filter unit and ensure that they are properly tightened.
DANGER
The crumb tray (if applicable) in portable filter systems must be emptied into a
fireproof container at the end of frying operations each day. Some food particles
can spontaneously combust if left soaking in certain shortening material.
5.4 Weekly
Follow the same procedure as for "Daily", with these additional steps:
•
Wash the filter pan with hot, soapy water and a brush. Dry and reassemble with new filter
paper.
•
•
Clean thoroughly under, around, and behind the fryers and filtering area.
Do not operate motor/pump until all traces of water have been removed from the pan.
Under no circumstances should water or boil-out solution be allowed to enter the pump
housing; irreparable damage will result, and all warranties will be voided.
•
Check the connections of the inlet lines and tighten if lines become loose or start to leak oil.
5-2
Download from Www.Somanuals.com. All Manuals Search And Download.
YPF95 SERIES PORTABLE FILTRATION SYSTEMS
CHAPTER 6: TROUBLESHOOTING
6.1 Operating Problems
Plugged lines and plugged filter paper account for over 90 percent of filtration system malfunctions.
A general troubleshooting chart included in this chapter provides systematic instructions to assist the
operator in diagnosing common malfunctions. Contact a factory-authorized service technician for
troubleshooting beyond the scope of the operator.
A. Plugged Lines
To guard against plugged lines when using solid shortening, let the faucet sputter for about 10-15
seconds at the end of each filter cycle. This will allow air to move through the lines and keep them
from becoming to be plugged.
B. Filter Powder and Plugged Paper
Improper use of the filter powder will cause filter paper to become plugged, sealed by a layer of
filter powder and debris. The first indication of paper plugging is a slow oil flow return rate and a
surging, jerking in the filter unit. To correct this, review the instructions for the correct use of filter
powder, and change the filter paper more frequently. When filtering several fryers prior to changing
paper, ensure that excess sediment is scraped off the filter paper after filtering each frypot. If
plugged paper remains a problem, review the chart in section 6.2 for proper diagnosis.
6.2 General Troubleshooting
The following chart contains information to assist the user in diagnosing the most common
malfunctions with portable filtration systems. Possible solutions and/or corrective actions are given
for each scenario.
If the malfunction cannot be diagnosed using the information in this section, contact your Factory
Authorized Service Agent for repairs.
DANGER
Use extreme care when testing electrical circuits. Live circuits will be exposed.
DANGER
Inspection, testing and repair of gas or electrical equipment should be performed by
qualified personnel.
6-1
Download from Www.Somanuals.com. All Manuals Search And Download.
YPF95 SERIES PORTABLE FILTRATION SYSTEMS
CHAPTER 6: TROUBLESHOOTING
6.2 General Troubleshooting (cont.)
Pump won't
start.
-
-
Tripped circuit breaker.
Incorrect or no line voltage.
- Allow filter unit to cool for at least 45 minutes and
then press the pump reset button on the side of the
filter.
- Turn filter pump "OFF". Allow oil to cool then empty
pan. Verify filter paper is clean and properly
installed. Refill pan and restart process.
Pump stops
during filtering
process.
- Reset circuit breaker.
- Pump is blocked or wiring is loose. Call FASC for
service.
- Filter pan suction tube is blocked. Use a thin, flexible
wire to unclog.
Pump starts
and abruptly
stops.
- Motor failed; call FASC for service.
Pumping is
erratic.
- Verify that filter paper is properly installed under
hold-down ring.
- Solidified oil or sediment is likely clogging the filter
hose. Clear hose.
- Clogged filter paper. Scrape off excess sediment or
replace filter paper.
Oil not being
returned to
frypot.
6-2
Download from Www.Somanuals.com. All Manuals Search And Download.
YPF95 SERIES PORTABLE FILTRATION SYSTEMS
CHAPTER 6: TROUBLESHOOTING
6.3 Wiring Diagrams
6.3.1 YPF95 120V Wiring
Switch Housing
Receptacle
120 VAC
BLK
BLK
GRN
WHT
BLK
BLK
ON/OFF Switch
CB
7 Amp Circuit Breaker
BLK
C
NC
BLK
P1
Thermal
Overload Reset
Switch
P2
T3
T8
T2
T4
T5
WHT
Motor
Terminal Box
120/230 VAC, 50/60 Hz Motor
w/Thermal Overload Protector
Electrical
Junction Box
6.3.2 YPF95 230V Wiring
Switch Housing
Receptacle
BRN
BLK
GRN-YEL
BLU
ON/OFF Switch
5 Amp Circuit Breaker
CB
230 Volt
BLK
NC
C
BLK
P1
T2
T3
T8
Thermal Overload
Reset Switch
T4
T5
BLU
Electrical
Junction Box
Motor
Terminal Box
(120/230V, 50/60 Hz Motor W/Thermal Overload Protector)
6-3
Download from Www.Somanuals.com. All Manuals Search And Download.
YPF95 SERIES PORTABLE FILTRATION SYSTEMS
CHAPTER 7: PARTS LIST
7 Main Components
7-1
Download from Www.Somanuals.com. All Manuals Search And Download.
YPF95 SERIES PORTABLE FILTRATION SYSTEMS
CHAPTER 7: PARTS LIST
7 Main Components
Item
Part #
Description
1
106-4589
200-8685
211-8703
212-8703
809-0417
810-1057
810-1668
813-0062
823-5022
823-5057
106-4608
824-1459
810-0180
809-0918
809-0191
106-4610
106-4613
106-4647
106-8342
200-8887
210-8733
210-8741
211-8723
211-8825
212-8723
212-8825
806-6034
807-1041
807-1043
807-1219
807-2469
809-0059
809-0120
809-0131
809-0189
809-0256
809-0412
Filter Pan Assembly
Sana Grid Screen
Stiffener, Pan Frame, Left
Stiffener, Pan Frame, Right
Nut, Flange, ¼"-20, Serrated
Flex Line, 5/8" OD x 13" Long
Adaptor, Male, 5/8" OD x ½"
Elbow, ½", 90°, Black Metal
Hold Down Ring
Filter Pan
2
Filter Pan Lid, Rear (larger)
Lid, Filter Pan
Handle, Filter Pan Lid
Screw, 10-24 x ½"
Washer, ¼" Spring Lock
Rear Panel, Filter
3
4
Cover Assembly, Top of Arm
Plumbing, Oil Return
Filter Pan Cover, Front
Cover, Filter Plug
5
6
7
8
Handle, Filter Unit
9
Pump Housing
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
Bracket, Handle, LT
Clip, 5/8", Handle, LT
Bracket, Handle, RT
Clip, 5/8", Handle, RT
Pump/Motor 115V, 60 Hz
Switch, Toggle, 120V, 15A
Bushing, 1.06 ID Heyco
Receptacle, 120V, 3 wire
Bushing, 1" ID, Heyco
Nut, Grip ¼-20 x ¾
Screw,10-32 x ½" Truss Head
Screw, Hex Head ¼"-20 x ¾
Washer, ¼" SAE Plain
Nut, Hex Keps 10-32
Screw, #10-1/2, Hex Head
7-2
Download from Www.Somanuals.com. All Manuals Search And Download.
YPF95 SERIES PORTABLE FILTRATION SYSTEMS
CHAPTER 7: PARTS LIST
7 Main Components
Item
Part #
Description
Nut, Flange, ¼"-20 Serrated
25
809-0417
809-0449
810-1668
810-2699
810-2700
810-2805
810-2806
810-2957
813-0006
813-0022
813-0062
813-0093
813-0625
823-5026
823-5027
823-6381
824-1460
824-1479
813-0165
813-0247
813-0265
26
Screw, #10 x ½", Phillip's Truss Head
Adaptor, Male 5/8" OD x ½"
27
28
Coupling, Quick Disconnect, Snaptite
Nipple, Quick Disconnect, Snaptite
Caster, 2", Filter Pan
29
30
31
Caster, 2" with Brake, Filter Pan
Tubing, Faucet, Over-the-Top
Bushing, Hex ½" to 3/8" NPT, Black Metal
Nipple, ½" x Close NPT, Black Metal
Elbow,1/2", 90°, Black Metal
32
33
34
35
36
Nipple, ½" x 4" NPT, Black Metal
Nipple,3/8" x Close NPT, Black Metal
Frame, Portable Filter
40
41
42
Tube, Oil Return
43
Tube, Oil Return, Over-the-Top
Cover, Housing Top
44
45
Plate, Filter Pump
*
Elbow, Street, ½" x ½" NPT, 90°, Black Metal
Nipple,1/2" x 3.50 NPT, Black Metal Pipe
Nipple, ½" x 2.50 NPT, Black Metal
*
*
* Not Illustrated
7-3
Download from Www.Somanuals.com. All Manuals Search And Download.
THIS PAGE INTENTIONALLY LEFT BLANK
Download from Www.Somanuals.com. All Manuals Search And Download.
Frymaster, L.L.C., 8700 Line Avenue, PO Box 51000, Shreveport, Louisiana 71135-1000
Shipping Address: 8700 Line Avenue, Shreveport, Louisiana 71106
TEL 1-318-865-1711
FAX (Parts) 1-318-219-7140
FAX (Tech Support) 1-318-219-7135
SERVICE HOTLINE
1-800-551-8633
819-6325
JUNE 2007
PRINTED IN THE UNITED STATES
Download from Www.Somanuals.com. All Manuals Search And Download.
|