Frymaster Fryer GF14 User Manual

Frymaster, a member of the Commercial Food Equipment Service Association, recommends  
using CFESA Certified Technicians.  
24-Hour Service Hotline  
* 8 1 9 5 8 M8AR720*02  
1-800-551-8633  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DANGER  
Adequate means must be provided to limit the movement of this appliance without depending  
upon the gas line connection. Single fryers equipped with legs must be stabilized by installing  
anchor straps. All fryers equipped with casters must be stabilized by installing restraining  
chains. If a flexible gas line is used, an additional restraining cable must be connected at all  
times when the fryer is in use.  
DANGER  
The front ledge of the fryer is not a step! Do not stand on the fryer. Serious injury can result  
from slips or contact with the hot oil.  
DANGER  
Do not store or use gasoline or other flammable liquids or vapors in the vicinity of this or any  
other appliance.  
DANGER  
Instructions to be followed in the event the operator smells gas or otherwise detects a gas leak  
must be posted in a prominent location. This information can be obtained from the local gas  
company or gas supplier.  
DANGER  
This product contains chemicals known to the state of California to cause cancer and/or birth  
defects or other reproductive harm.  
Operation, installation, and servicing of this product could expose you to airborne particles of  
glasswool or ceramic fibers, crystalline silica, and/or carbon monoxide. Inhalation of airborne  
particles of glasswool or ceramic fibers is known to the State of California to cause cancer.  
Inhalation of carbon monoxide is known to the State of California to cause birth defects or other  
reproductive harm.  
NOTICE  
The Commonwealth of Massachusetts requires any and all gas products to be installed by a  
licensed plumber or pipe fitter.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
GF14 and GF40 SERIES GAS FRYERS  
TABLE OF CONTENTS  
CHAPTER 1: General Information  
1.1  
1.2  
1.3  
1.4  
1.5  
1.6  
Parts Ordering and Service Information .............................................................. 1-1  
Safety Information ............................................................................................... 1-2  
Equipment Description ........................................................................................ 1-2  
Installation, Operating, and Service Personnel.................................................... 1-3  
Definitions............................................................................................................ 1-3  
Shipping Damage Claim Procedure..................................................................... 1-4  
CHAPTER 2: Installation Instructions  
2.1  
2.2  
2.3  
2.4  
2.5  
General Installation Requirements....................................................................... 2-1  
Caster/Leg Installation......................................................................................... 2-2  
Pre-Connection Preparations ............................................................................... 2-2  
Connection to Gas Line ....................................................................................... 2-3  
Converting to Another Gas Type......................................................................... 2-4  
CHAPTER 3: Operating Instructions  
3.1  
3.2  
3.3  
3.4  
3.5  
3.6  
Start-Up Procedures............................................................................................. 3-1  
Boiling Out the Frypot......................................................................................... 3-2  
Filling with Cooking Oil or Shortening............................................................... 3-3  
Shutting the Fryer Down...................................................................................... 3-3  
Thermostat Operation .......................................................................................... 3-3  
Draining and Filtering.......................................................................................... 3-4  
CHAPTER 4: Preventive Maintenance and Operator Troubleshooting  
4.1  
4.2  
4.3  
4.4  
Daily Checks and Services................................................................................... 4-1  
Quarterly Checks and Services............................................................................ 4-1  
Semi-Annual Checks and Services...................................................................... 4-3  
Operator Troubleshooting.................................................................................... 4-4  
i
Download from Www.Somanuals.com. All Manuals Search And Download.  
GF14 and GF40 SERIES GAS FRYERS  
CHAPTER 1: GENERAL INFORMATION  
1.1  
Parts Ordering and Service Information  
In order to assist you as quickly as possible, the Frymaster Factory Authorized Service Center  
(FASC) or Service Department representative requires certain information about your equipment.  
Most of this information is printed on a data plate affixed to the inside of the fryer door. A typical  
data plate is illustrated below.  
GF14SD  
1050  
0201FM0208  
4.00  
AF  
10000  
NAT  
1.65  
000  
.00  
Parts orders must be placed directly with your local FASC or distributor. Included with fryers when  
shipped from the factory is a list of Frymaster FASCs. If you do not have access to this list, contact  
the Frymaster Technical Service Department at 1-800-551-8633 or 1-318-865-1711.  
When ordering parts, the following information is required:  
Model Number:  
Serial Number:  
Type of Gas:  
Item Part Number:  
Quantity Needed:  
Service information may be obtained by contacting your local FASC. Information may also be  
obtained by calling the Frymaster Technical Service Department at 1-800-551-8633 or 1-318-865-  
1711.  
When requesting service, please have the following information ready:  
Model Number:  
Serial Number:  
Type of Gas:  
In addition to the model number, serial number, and type of gas, please be prepared to describe the  
nature of the problem and have ready any other information that you think may be helpful in solving  
your problem.  
RETAIN AND STORE THIS MANUAL IN A SAFE PLACE FOR FUTURE USE.  
1-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1.2  
Safety Information  
Before attempting to operate your unit, read the instructions in this manual thoroughly.  
Throughout this manual, you will find notations enclosed in double-bordered boxes similar to the  
ones below.  
CAUTION boxes contain information about actions or conditions that may cause or result in a  
malfunction of your system.  
CAUTION  
Example of a CAUTION box.  
WARNING boxes contain information about actions or conditions that may cause or result in dam-  
age to your system, and which may cause your system to malfunction.  
WARNING  
Example of a WARNING box.  
DANGER boxes contain information about actions or conditions that may cause or result in injury to  
personnel, and which may cause damage to your system and/or cause your system to malfunction.  
DANGER  
Hot cooking oil or shortening causes severe burns. Never attempt to move a fryer  
containing hot cooking oil/shortening or to transfer hot cooking oil/shortening from  
one container to another.  
1.3  
Equipment Description  
The GF14 and GF40 Series gas fryers are designed for all-purpose frying. Other than the capacity of  
the frypot, both fryers are virtually identical. The GF14 model holds up to 40 lbs. (20 liters) of  
cooking oil or shortening. GF40 fryers hold up to 50 lbs. (25 liters). Both models must be manually  
filtered or filtered with a portable filtration unit such as the Frymaster PF50 portable filter.  
These fryers use a millivolt temperature control circuit, which requires no external power.  
Both models use an open-pot design with no tubes and have a hand-sized opening into the deep cold  
zone, which makes cleaning the frypot quick and easy.  
The fryers require installation of legs or optional casters at point of use. All fryers are shipped with  
a package of standard accessories. Each fryer is adjusted, tested, and inspected at the factory before  
crating for shipment.  
Frypots are constructed of welded, heavy-gauge stainless steel or cold-rolled steel. Heat is supplied  
by a burner assembly having multiple gas jets, which are focused on deflectors (commonly referred  
to as “targets”) located around the lower side of the frypot. The deflectors concentrate the heat  
produced by the burners on the bottom of the frypot.  
1-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
The burner assembly can be configured for natural gas, propane, or manufactured gas, as required by  
the customer. A drain is tapped into the center of the frypot, with a front-controlled manual ball  
valve.  
Each fryer is equipped with a thermostat for precise temperature control. The thermostat is located  
near the centerline of the frypot for rapid response to changes in loads and to provide the most  
accurate temperature measurement.  
A high temperature thermostat (hi-limit) shuts off gas to the burner assembly if the controlling  
thermostat fails.  
1.4  
Installation, Operating, and Service Personnel  
Operating information for Frymaster equipment has been prepared for use by qualified and/or au-  
thorized personnel only, as defined in Section 1.5.  
All installation and service on Frymaster equipment must be performed by qualified, certified,  
licensed, and or/authorized installation or service personnel, as defined in Section 1.5.  
1.5  
Definitions  
QUALIFIED AND/OR AUTHORIZED OPERATING PERSONNEL  
Qualified/authorized operating personnel are those who have carefully read the information in this  
manual and have familiarized themselves with the equipment functions, or who have had previous  
experience with the operation of the equipment covered in this manual.  
QUALIFIED INSTALLATION PERSONNEL  
Qualified installation personnel are individuals, or firms, corporations, or companies which, either in  
person or through a representative, are engaged in and are responsible for the installation of gas-  
fired appliances. Qualified personnel must be experienced in such work, be familiar with all gas  
precautions involved, and have complied with all requirements of applicable national and local  
codes.  
QUALIFIED SERVICE PERSONNEL  
Qualified service personnel are those that are familiar with Frymaster equipment and who have been  
authorized by Frymaster to perform service on Frymaster equipment. All authorized service  
personnel are required to be equipped with a complete set of service and parts manuals and stock a  
prescribed minimum amount of Frymaster equipment parts.  
A list of Frymaster Factory Authorized Service Centers (FASC) is included with the fryer when it  
ships from the factory. Failure to use qualified service personnel will void the Frymaster  
Warranty on your equipment.  
1-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1.6  
Shipping Damage Claim Procedure  
Your Frymaster equipment was carefully inspected and packed before leaving the factory. The  
transportation company assumes full responsibility for safe delivery upon acceptance of the  
equipment for transport.  
What to do if your equipment arrives damaged:  
1. File a claim for damages immediately, regardless of the extent of damages.  
2. Inspect for and record all visible loss or damage, and ensure that this information is noted on  
the freight bill or express receipt and is signed by the person making the delivery.  
3. Concealed loss or damage that was unnoticed until the equipment was unpacked should be  
recorded and reported to the freight company or carrier immediately upon discovery. A  
concealed damage claim must be submitted within 15 days of the date of delivery. Ensure that  
the shipping container is retained for inspection.  
Frymaster DOES NOT ASSUME  
RESPONSIBILITY FOR DAMAGE OR LOSS  
INCURRED IN TRANSIT.  
1-4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
GF14 and GF40 SERIES GAS FRYERS  
CHAPTER 2: INSTALLATION INSTRUCTIONS  
2.1  
General Installation Requirements  
PROPER INSTALLATION IN ACCORDANCE WITH THE INSTRUCTIONS THAT FOLLOW IS ESSENTIAL  
FOR EFFICIENT, TROUBLE-FREE OPERATION OF YOUR FRYER. ANY UNAUTHORIZED  
ALTERATIONS MADE TO THIS EQUIPMENT WILL VOID THE FRYMASTER WARRANTY.  
Upon arrival, inspect the fryer carefully for visible or concealed damage. (See Shipping Damage  
Claim Procedure in Chapter 1.)  
CLEARANCE AND VENTILATION  
The fryer(s) must be installed with a 6” (150 mm) clearance at both sides and back when installed  
adjacent to combustible construction; no clearance is required when installed adjacent to  
noncombustible construction. A minimum of 24” (600 mm) clearance should be provided at the  
front of the fryer.  
One of the most important considerations of efficient fryer operation is ventilation. Make sure the  
fryer is installed to efficiently remove combustion by-products, and the kitchen ventilation system  
does not produce drafts that interfere with proper burner operation.  
The fryer flue opening must not be placed close to the intake of the exhaust fan, and the fryer must  
never have its flue extended in a “chimney” fashion. An extended flue will change the combustion  
characteristics of the fryer, causing longer recovery time. It also frequently causes delayed ignition.  
To provide the airflow necessary for good combustion and burner operation, the areas surrounding  
the fryer front, sides, and rear must be kept clear and unobstructed.  
Fryers must be installed in an area with an adequate air supply and adequate ventilation. Adequate  
distances must be maintained from the flue outlet of the fryer to the lower edge of the ventilation  
filter bank. Filters should be installed at an angle of 45º. Place a drip tray beneath the lowest edge  
of the filter. For U.S. installation, NFPA standard No. 96 states, “A minimum distance of 18 in.  
(450 mm) should be maintained between the flue outlet and the lower edge of the grease filter.”  
Frymaster recommends that the minimum distance be 24 in. (600 mm) from the flue outlet to the  
bottom edge of the filter.  
DANGER  
No structural material on the fryer should be altered or removed to accommodate  
placement of the fryer under a hood. Questions? Call the Frymaster/Dean Service  
Hotline at 1-800-551-8633.  
Information on construction and installation of ventilating hoods can be found in the NFPA standard  
cited above. A copy of the standard may be obtained from the National Fire Protection Association,  
Battery March Park, Quincy, MA 02269.  
2-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DANGER  
Do not attach an apron drainboard to a single fryer. The fryer may become unstable,  
tip over, and cause injury. The appliance area must be kept free and clear of  
combustible material at all times.  
NATIONAL CODE REQUIREMENTS  
The type of gas for which the fryer is equipped is marked on the data plate attached to the inside of  
the fryer door. Connect a fryer marked “NAT” only to natural gas, those marked “PRO” only to  
propane gas, and those marked “MFG” only to manufactured gas.  
When installing this equipment in the UNITED STATES, the installation must conform to the latest  
edition of the National Fuel Gas Code, ANSI Z223.1. In CANADA, installation must conform to  
the latest edition of Standard CAN-/GCA-B149.1 or .2, “Installation Codes for Gas Burning  
Appliances & Equipment”. In addition to the applicable national code or standard, installation must  
also be in accordance with any local codes for the area in which the equipment is installed.  
In AUSTRALIA, this appliance must be installed by an authorized person, in accordance with the  
manufacture’s instructions, local gas regulations, and requirements of AA601, “Installation  
Requirements for Gas Burning Appliances”.  
Installation shall be made with a gas connector that complies with national and local codes. In the  
UNITED STATES, the applicable code is ANSI Z21.69 with Addenda, “Standard for Connectors  
for Movable Gas Appliances”. Quick-Disconnect devices, if used, shall likewise comply with  
national and local codes. In the UNITED STATES, the code is ANSI Z21.41, “Standard for Quick-  
Disconnect Devices for Use with Gas Fuel”.  
2.2  
Caster/Leg Installation  
Depending upon the specific configuration ordered, your fryer may have been shipped without  
installed casters or legs. If casters or legs are installed, you may skip this section and proceed to  
Section 2.3, Pre-Connection Preparations. Fryers must have casters or legs. Fryers cannot be curb  
mounted.  
Install the casters/legs in accordance with the instructions included in your accessory package.  
2.3  
Pre-Connection Preparations  
DANGER  
Do not connect fryer to gas supply before completing each step  
in this section.  
After the fryer has been positioned under the fry station exhaust hood, ensure the following has been  
accomplished:  
1. Adequate means must be provided to limit the movement of fryers without depending upon the  
gas line connections. If a flexible gas hose is used, a restraining cable must be connected at all  
2-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
times when the fryer is in use. The restraining cable and installation instructions are packed with  
the flexible hose in the accessories box that was shipped with your unit.  
2. These fryers must be stabilized by installing restraining chains on fryers equipped with casters or  
anchor straps on fryers equipped with legs. Follow the instructions shipped with the casters/legs  
to properly install the chains or straps.  
3. Level fryers equipped with legs by extending the adjustable portion of the leg out approximately  
1 inch, and then further adjust the legs, ensuring the fryer is level and at the proper height in the  
exhaust hood. Frymaster recommends that the minimum distance from the flue outlet to the  
bottom edge of the filter be 24 in. (600 mm).  
For fryers equipped with casters, there are no built-in leveling devices. The floor where the fryer  
is to be installed must be level.  
4. Refer to the data plate on the inside of the fryer door to verify that the fryer is configured for the  
proper type of gas before connecting the fryer quick-disconnect device or piping from the gas  
supply line.  
5. Verify that the minimum and maximum gas supply pressures for the type of gas to be used are in  
accordance with the table below.  
Standard for Incoming Gas  
Pressure  
Gas  
Minimum  
Maximum  
6” WC  
1.49 kPa  
14.94 mbar  
14” WC  
3.49 kPa  
34.87 mbar  
Natural  
11” WC  
2.74 kPa  
14” WC  
3.49 kPa  
LP  
27.37 mbar  
34.87 mbar  
2.4  
Connection to Gas Line  
The size of the gas line used for installation is very important. If the line is too small, the gas  
pressure at the burner manifold will be low. This may cause pilot outage, slow recovery and delayed  
ignition. The incoming gas supply line should be a minimum of 1½” (38 mm) in diameter. All  
single GF14/GF40 fryers using natural gas require a ¾” connection. Batteries of two and three  
fryers require a 1” connection. For fryers using LP gas, one pipe size smaller may be used. If in  
doubt about the correct pipe size, consult the local gas company.  
NOTE: Runs of more than 20 feet and more than 4 fittings or elbows require an increase of one  
pipe size, i.e., ¾” to 1” or 1” to 1¼”.  
Before connecting new pipe to your unit, the pipe must be thoroughly blown out to remove any  
foreign particles. If these foreign particles get into the burner and controls, they will cause improper  
and sometimes dangerous operation.  
2-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Connect the quick-disconnect hose to the fryer quick-disconnect fitting at the rear of the fryer  
and to the building gas line.  
NOTE: Some fryers are configured for a rigid connection to the gas supply line. These units  
are connected directly to the gas supply line.  
When using thread compound, use very small amounts on male threads only. Use a pipe thread  
compound that is not affected by the chemical action of LP gases (Loctite™ PST56765 Sealant  
is one such compound). DO NOT apply compound to the first two threads. This will ensure that  
the burner orifices and control valve do not become clogged.  
2. Open the gas supply to the fryer and check all piping, fittings, and gas connections for leaks. A  
soap and water solution should be used for this purpose.  
DANGER  
Never use matches, candles, or any other ignition source to check for leaks.  
If gas odors are detected, shut off the gas supply to the fryer at the main shut-off  
valve and contact the local gas company or an authorized service agency for service.  
NOTE: The fryer must be disconnected from the gas supply piping during any pressure testing  
of the gas supply piping a pressures equal to or greater than ½ psig (3.45kPa or 13.84 in. W.C.).  
3. Close the fryer drain valve and fill the frypot with water or boil-out solution to the bottom OIL-  
LEVEL line at the rear of the frypot. Light the fryer and perform the boil-out procedures that are  
described in the “Start-Up Procedure” and “Boiling Out the Frypot” topics found in Chapter 3 of  
this manual.  
WARNING  
“Dry-firing” your unit will cause damage to the frypot. Always ensure that melted  
shortening, cooking oil, or water is in the frypot before firing your unit.  
4. It is suggested that the burner manifold pressure be checked at this time by the local gas  
company or an authorized service agent. Refer to “Check Burner Manifold Pressure” in Section  
4.3 of this manual for the proper procedure.  
5. Check the thermostat calibration in accordance with the instructions in Section 4.3 of this  
manual.  
2.5  
Converting to Another Gas Type  
DANGER  
Switching to a different type of gas without installing the proper conversion kit may  
result in fire or explosion.  
NEVER ATTACH YOUR FRYER TO A GAS SUPPLY FOR WHICH IT IS NOT  
CONFIGURED!  
2-4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Your fryer is configured at the factory for either natural gas or Propane (LP) gas. If you desire to  
switch from one type of gas to another, a Factory Authorized Service Center technician must  
install a gas conversion kit.  
Call Frymaster Service (1-800-551-8633) to determine the conversion kit appropriate for your  
configuration and altitude. Contact your local FASC to order the kit and arrange for installation.  
2-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
GF14 and GF40 SERIES GAS FRYERS  
CHAPTER 3: OPERATING INSTRUCTIONS  
3.1  
Start-Up Procedure  
CAUTION  
If this is the first time the fryer is being used after installation, refer to Section  
3.2, Boil-Out Procedure.  
CAUTION  
The cooking oil/shortening capacity of the GF14 Series fryer is 40 lbs. (20  
liters) at 70ºF (21ºC).  
The cooking oil/shortening capacity of the GF40 Series fryer is 50 lbs. (25  
liters) at 70°F (21°C).  
Before lighting the fryer, make sure the fryer is OFF and the frypot drain valve  
is closed. Remove the basket support rack, if installed, and fill the frypot to  
the bottom OIL-LEVEL line.  
To prevent scorching, if solid shortening is being used, make sure it is tightly  
packed down into the bottom of the frypot.  
Operating the Gas Valve:  
The knob on the Honeywell gas valve is placed in the PILOT or ON position by rotating it  
counter-clockwise. To return the knob to the OFF position, the knob must be depressed  
slightly to disengage its stop tab, then rotated clockwise.  
Lighting the Pilot and Burner:  
WARNING  
Frypot must be filled with water or cooking oil/shortening before lighting.  
1. Open the door and turn the thermostat knob to the desired frying temperature (or  
275°F/135°C if boiling out the frypot).  
2. Rotate the gas valve knob to the PILOT position (see Figure 1).  
Lighting the Pilot and Burner  
T
P I L O  
P I L O T  
Figure 1  
Figure 2  
3-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. Push the knob in and light the pilot. Continue to hold the knob in for about 60 seconds  
after the flame appears on the pilot. Release the knob. The pilot should remain lit.  
CAUTION  
If the pilot fails to remain lit, wait five minutes before attempting to re-light.  
4. With the pilot lit, push down and slowly turn the knob to the ON position (see Figure 2  
on Page 3-1).  
5. The burner should light and burn with a strong blue flame. Once the burner has been lit,  
it is controlled by the thermostat.  
CAUTION  
If the pilot and main burner go out, the fryer(s) must be completely shut down  
at least five minutes before re-lighting.  
3.2  
Boiling Out the Frypot  
To ensure that the frypot is free of any contamination resulting from its manufacture,  
shipping, and handling during installation, the frypot must be boiled out before first use.  
Frymaster recommends boiling out the frypot each time the oil or shortening is changed.  
1. Before lighting the burner, close the frypot drain valve and fill the frypot with a mixture  
of cold water and boil-out solution or detergent. Fill to the lower oil-level line.  
2. Light the fryer in accordance with the lighting instructions in Section 3.1.  
3. Simmer the solution for one hour.  
DANGER  
Never leave the fryer unattended during the boil-out process. If the boil-out  
solution boils over, turn the fryer off immediately and let the solution cool for  
a few minutes before resuming the process. To lessen the chance of boil  
over, turn the fryer’s gas valve knob to the PILOT position occasionally.  
4. After the solution has simmered for one hour, turn the gas valve knob to the PILOT  
position and allow the solution to cool.  
5. Add one gallon (3.8 liters) of cold water and stir. Drain the solution into a suitable  
container and clean the frypot thoroughly.  
WARNING  
Do not drain boil-out solution into a shortening disposal unit or portable filter  
unit. These units are not intended for this purpose, and will be damaged by  
the solution.  
3-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6. Rinse the frypot at least twice by filling the frypot with clean water and draining. Dry the  
frypot thoroughly with a clean, dry towel.  
DANGER  
Remove all drops of water from the frypot before filling with cooking oil or  
shortening. Failure to do so may cause spattering of hot liquid when the oil or  
shortening is heated to cooking temperature.  
3.3  
Filling With Cooking Oil or Shortening  
The GF14 Series fryer holds a minimum of 30 lbs. (15 liters) and a maximum of 40 lbs. (20  
liters) of cooking oil or shortening at 70°F (21°C).  
The GF40 Series fryer holds a minimum of 40 lbs. (20 liters) and a maximum of 50 lbs. (25  
liters) of cooking oil or shortening at 70°F (21°C).  
1. Ensure the fryer’s gas valve is off or in the pilot position.  
2. Close the frypot drain valve; remove the basket support rack if required.  
3. Fill the frypot to the lower oil-level line. When solid shortening is used, it must be  
thoroughly packed down into the frypot’s cold zone.  
4. To melt solid shortening without scorching, the gas valve knob should be turned to the  
ON position for about three seconds and then to the PILOT position for about 10  
seconds repeatedly until the shortening is completely melted. If any smoke is seen during  
this process, the oil is heating too quickly and scorching. This melting process is not  
necessary with liquid shortening.  
3.4  
Shutting the Fryer Down  
For short-term shut down during the workday, rotate the gas valve knob clockwise to the  
PILOT position (see Figure 1 on Page 3-1) and put the frypot covers in place (if the fryer is  
so equipped).  
When shutting the fryers down at closing time, rotate the gas valve knob to the PILOT  
position (see Figure 1 on Page 3-1). Depress the gas valve knob and rotate slightly  
clockwise. Release and continue rotating clockwise to the OFF position (see Figure 2 on  
Page 3-1). Put the frypot covers in place (if the fryer is so equipped).  
3.5  
Thermostat Operation  
The thermostat on GF14/GF40 fryers is connected to a graduated knob located inside the  
fryer door. On GF14 models, the knob is on the left side; in GF40 models, the knob is on the  
right side. Rotating the knob clockwise to the desired cooking temperature (setpoint)  
directly adjusts the thermostat to that temperature. The thermostat controls the frypot  
temperature by regulating the gas supply to the burner via the gas valve.  
3-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
The thermostat is in the full OFF position when the word OFF is at the top of the knob. A  
“click” will be heard when the knob is rotated from the OFF position to a temperature, or  
when it is rotated back to the OFF position.  
The thermostat may require calibration from time to time. To determine if it requires  
calibration, refer to Check Thermostat Calibration in Section 4.2 of this manual.  
3.6  
Draining and Filtering  
DANGER  
Draining and filtering of cooking oil or shortening must be accomplished with  
care to avoid the possibility of a serious burn caused by careless handling.  
Frymaster recommends that elbow-length, heat-resistant rubber gloves be  
worn when draining or filtering cooking oil or shortening.  
Cooking oil or shortening should be filtered at least twice daily and more often if a heavy  
volume of breaded product is fried. Filtering will greatly increase the life of the cooking oil  
or shortening and will produce a higher quality product. Frymaster recommends the use of  
the Frymaster PF50 Portable Filter.  
NOTE: When using a portable filtration unit, refer to the unit manufacturer’s operating  
instructions for the proper filtering procedures.  
The following procedure is recommended to drain and filter your cooking oil or shortening  
when a portable filtration unit is not available.  
DANGER  
NEVER attempt to drain cooking oil or shortening from the fryer with the  
burner lit! Doing so may result in a flash fire if the oil or shortening splashes  
onto the burner. Also, applying burner heat to an empty frypot will severely  
damage the frypot and void the Frymaster warranty.  
1. Rotate the gas valve knob to the PILOT or OFF position. Screw the drain extension  
supplied with the fryer securely into the drain valve, making sure the opening is pointing  
down (see illustration below).  
Drain Extension in  
stowed position.  
Drain Extension screwed  
into drain valve.  
3-4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
NOTE: If draining the fryer to dispose of the cooking oil or shortening, Frymaster  
recommends the use of a wheeled disposal unit equipped with a pump, such as the  
Frymaster SDU 50. When using a disposal unit, follow the unit manufacturer’s  
instructions.  
2. Position a metal container with a sealable cover under the drain extension. The metal  
container must be capable of withstanding the hot cooking oil or shortening without  
leaking. Frymaster recommends that a Frymaster filter cone holder and filter cone be  
used when a portable filtration unit is not available. If you are using a Frymaster filter  
cone holder and filter cone, be sure that the cone holder rests securely on the metal  
container.  
3. Open the drain valve slowly to avoid splattering.  
4. If the drain valve becomes clogged with food particles, use a cleanout rod, available from  
Frymaster, to clear the valve by inserting it into the drain opening from the INSIDE of  
the frypot.  
DANGER  
NEVER attempt to clear a clogged valve from the front of the valve! Hot oil or  
shortening will rush out creating the potential for severe burns.  
DO NOT hammer on the drain valve with the rod or other objects. Damage to  
the ball inside will result in leaks and will void the Frymaster warranty.  
5. The drained shortening should be allowed to cool to 100°F (38°C) or lower before  
transporting the container and removing the drain extension. Cooking oil or shortening at  
a temperature of 140°F (60°C) or higher will result in severe burns if it comes in contact  
with your skin.  
6. After draining the cooking oil or shortening, clean all food particles and residual  
oil/shortening from the frypot before refilling. Be careful! The residual oil/shortening  
remains hot enough to cause severe burns if it comes in contact with your skin.  
7. Close the drain valve and refill the frypot with clean, filtered cooking oil or shortening to  
the lower oil level line.  
3-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
GF14 and GF40 SERIES GAS FRYERS  
CHAPTER 4: PREVENTIVE MAINTENANCE AND  
OPERATOR TROUBLESHOOTING  
4.1  
Daily Checks and Services  
Inspect Fryer and Accessories for Damage  
Look for loose or frayed wires, leaks, foreign material in frypot or inside cabinet, and any other  
indications that the fryer and accessories are not ready and safe for operation.  
Inspect the burner deflectors or targets to verify that each is positioned directly above its orifice, and  
that the flame ignites approximately 2½ inches (60mm) above the orifice. The flame should strike  
the center of the deflector and be a rich blue color. Call your Factory Authorized Service Center  
(FASC) if you see any problems.  
Clean Fryer Cabinet Inside and Out  
Clean inside the fryer cabinet with dry, clean cloth. Wipe all accessible metal surfaces and  
components to remove accumulations of oil or shortening and dust.  
Clean the outside of the fryer cabinet with a clean, damp cloth soaked with dishwashing detergent,  
removing oil/shortening, dust, and lint from the fryer cabinet.  
DANGER  
Never attempt to clean the fryer during the cooking process or when the frypot is  
filled with hot oil/shortening. If water comes in contact with oil/shortening heated to  
cooking temperature, it can cause the oil/shortening to splatter and severely burn  
nearby personnel.  
Filter Cooking Oil/Shortening  
The cooking oil/shortening used in your fryer should be filtered at least twice every day (more often  
if the fryer is in constant use). Refer to Section 3.6, “Draining and Filtering”, for details.  
4.2  
Quarterly Checks and Services  
Drain and Clean Frypot  
During normal usage of your fryer, a deposit of carbonized cooking oil or shortening will gradually  
form on the inside of the frypot. This deposit must be periodically removed to maintain your fryer’s  
efficiency.  
Follow the procedures for draining the frypot in Section 3.6, the follow the “Boiling Out the Frypot”  
procedures in Section 3.2.  
4-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Clean Detachable Parts and Accessories  
As with the frypot, a deposit of carbonized oil/shortening will accumulate on detachable parts and  
accessories such as baskets and sediment trays.  
Wipe all detachable parts and accessories with a clean cloth dampened with a detergent solution.  
(Frymaster recommends the use of Frymaster Fryer ‘N’ Griddle Cleaner, available through your lo-  
cal distributor, for best results.) Rinse and thoroughly dry each part.  
Check Thermostat Calibration  
1. Set the temperature control knob to 375°F (191°C), i.e., fully clockwise.  
2. Let the burner cycle on and off automatically three times in order for the cooking oil/shortening  
temperature to become uniform. If necessary, stir to get all shortening in the bottom of the fry-  
pot melted.  
3. Insert a good-grade thermometer or pyrometer probe into the oil/shortening, with the end near  
the fryer temperature-sensing probe. NOTE: The temperature-sensing probe is held by clips  
welded to the frypot. In GF14 fryers, the probe is on the left side of the frypot; in GF40 models,  
it is on the right side.  
4. When the burner starts for the fourth time, the thermometer/pyrometer reading should be within  
the range 355-385°F (185-196°C). If it is not, calibrate as follows:  
a. Remove the thermostat knob by pulling straight out on the knob with a firm, steady pull.  
b. Using a small-bladed flat-tipped screwdriver inserted into the slot in the thermostat adjusting  
screw, turn the adjusting screw in ¼-turn increments to adjust the temperature. Turning the  
screw clockwise decreases the temperature; turning it counter-clockwise increases the  
temperature. DO NOT allow the thermostat shaft to turn while turning the adjusting screw.  
c. Recheck the thermometer/pyrometer reading the next time the burner comes on.  
d. Repeat steps 4.b. through 4.c. until the thermometer/pyrometer reading remains within the  
range 355-385°F (185-196°C) through several cycles. If calibration cannot be obtained for  
any reason, call a Factory Authorized Service Center for assistance.  
e. Reinstall the thermostat knob.  
5. Remove the thermometer or pyrometer.  
Clean Gas Valve Vent Tube  
1. Carefully unscrew the vent tube from the gas valve. NOTE: The vent tube may be straightened  
for ease in removal.  
2. Pass a piece of ordinary binding wire (.052 inch diameter) through the tube to remove any  
obstruction.  
3. Remove the wire and blow through the tube to ensure it is clear.  
4-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. Reinstall tube and bend it so that the opening is pointing downward.  
4.3 Semi-Annual Checks and Service  
Check Burner Manifold Pressure  
WARNING  
This task should be performed by qualified service personnel only.  
WARNING  
The frypot must be filled with water or cooking oil/shortening during this procedure.  
1. Ensure that the gas valve knob is in the OFF position.  
2. Remove the pressure tap plug from burner manifold.  
Pressure  
Tap Plug  
3. Insert the fitting for a manometer or pressure gauge into the pressure tap hole.  
4. Place the gas valve in the PILOT position and light the pilot. When the pilot lights and  
continues to burn, increase the setting on the thermostat knob until the burner lights. Compare  
the manometer or gauge reading to the appropriate table below.  
GF14 Standard  
GF40 Standard  
for Burner Manifold Pressure  
for Burner Manifold Pressure  
Gas Type  
Pressure  
4.0” WC  
(1.00 kPa or 9.96 mbar)  
10.0” W.C  
(2.49 kPa or 24.91 mbar)  
Gas Type  
Pressure  
3.5” WC  
(0.87 kPa or 8.72 mbar)  
8.25” W.C.  
(2.06 kPa or 20.55 mbar)  
Natural  
LP  
Natural  
LP  
4-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5. If the burner manifold pressure does not meet the specifications in the tables in Step 4, unscrew  
the slotted cap from the top of the gas valve regulator (adjacent to the gas valve vent tube) and  
turn the adjusting screw to obtain the correct pressure. Turn the screw clockwise to increase  
pressure, counter-clockwise to decrease pressure.  
6. After adjusting the manifold pressure to the correct value, reinstall the regulator cap and turn the  
gas valve knob to the OFF position.  
7. Remove the manometer or pressure gauge fitting from the pressure tap hole and reinstall the pipe  
plug.  
8. Place the gas valve in the PILOT position and check for gas leaks. If no leaks are found, re-light  
the pilot and return the unit to operation.  
4.4  
Operator Troubleshooting  
The tables that follow provide operators with a list of possible malfunctions, the probable causes of  
the malfunctions, and the corrective actions to take to correct the problem.  
In some cases the operator may not be able to correct the problem, but will at least be able to  
accurately diagnose the problem, and that will assist a qualified service technician in restoring the  
equipment to full operation in the shortest possible time.  
4-4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Problem  
Probable Cause  
A. Pilot is not lit.  
B. Loose, dirty, or corroded terminals B. Clean and tighten terminals on gas  
Corrective Action  
A. Light pilot.  
on gas valve. valve.  
C. Loose, dirty, or corroded terminals C. Clean and tighten terminals on  
on thermostat.  
thermostat.  
D. Thermostat, gas valve, or hi-limit  
wires broken or shorted.  
D. Examine wires for signs of  
abrasions, cuts, kinks, etc. If the  
wiring is obviously damaged, it  
will probably be necessary to  
replace the associated component.  
Call FASC.  
Burner does  
not light at all.  
E. Thermostat out of calibration.  
E. Check calibration of thermostat in  
accordance with procedures in  
Section 4.2 of this manual.  
F. If the above causes have all been  
ruled out, the probable causes are  
a failed thermostat or a failed gas  
valve.  
F. Call FASC.  
A. One or more burner orifices  
clogged.  
A. Turn gas valve knob to OFF  
position. Use thin wire to clear  
obstruction from burner orifices.  
B. Blocked flue.  
B. Clear blockage from flue.  
C. Fryer flue connected directly to  
vent hood with a chimney-like  
duct.  
C. Remove chimney-like duct and  
allow for at least 18” (45.7cm) be-  
tween flue outlet and vent hood  
filters.  
Burner does  
not light all the  
way around.  
D. If the above causes have all been  
ruled out, the probable causes are  
a broken or missing target (GF40),  
a bent or missing flame deflector  
(GF14), or incorrect burner gas  
pressure.  
D. Call FASC.  
4-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Problem  
Probable Cause  
Corrective Action  
A. Too little make-up air in kitchen.  
A. Adjust kitchen ventilation system  
to increase make-up air.  
B. Pilot flame directed away from  
first orifice of burner.  
B. Reposition pilot hood to direct  
flame toward first burner orifice.  
Burner  
experiences  
delayed  
C. One or more burner orifices  
clogged.  
C. Use a thin wire to clear  
obstruction from orifices.  
D. If the above causes have all been  
ruled out, the probable causes are  
low pilot flame (less than 1”  
(25mm)), low incoming gas pres-  
sure, or a too small incoming gas  
line.  
D. Call FASC  
ignition.  
A. Flue obstructed.  
A. Remove obstruction from flue.  
Flame rolling  
out from under  
fryer.  
B. Too little make-up air in kitchen.  
B. Adjust kitchen ventilation system  
to increase make-up air.  
A. Clogged pilot orifice.  
A. Use a small wire to clear  
obstruction from pilot orifice.  
B. Pilot flame blowing away from  
pilot generator (excessive draft in  
kitchen).  
B. Eliminate draft in kitchen.  
C. Pilot generator not inserted fully  
into pilot burner.  
C. Reinsert pilot generator into pilot  
burner until flame surrounds tip.  
Pilot repeatedly  
goes out.  
D. Corroded connection where pilot  
generator connects to gas valve.  
D. Clean pilot generator connection  
at gas valve.  
E. If all of the above causes have  
been ruled out, the probable  
causes are low pilot flame, pilot  
generator low millivolt output,  
high resistance in hi-limit  
E. Call FASC.  
thermostat contacts, or a defective  
pilot magnet in the gas valve.  
4-6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Problem  
Probable Cause  
Corrective Action  
A. Loose, dirty or corroded hi-limit  
wires.  
A. Clean/tighten hi-limit wires on gas  
valve.  
Pilot remains lit  
when gas valve  
knob is pushed  
in, but goes out  
when released.  
B. If the above does not correct the  
problem, the probable causes are a  
weak gas valve pilot magnet, pilot  
generator low millivolt output, or  
a high-limit thermostat stuck open.  
B. Call FASC.  
A. Thermostat out of calibration.  
A. Check calibration of thermostat in  
accordance with procedures in  
Section 4.2 of this manual.  
Thermostat  
does not control  
at set point.  
B. Failed thermostat.  
B. Call FASC.  
4-7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Frymaster, L.L.C., 8700 Line Avenue, PO Box 51000, Shreveport, Louisiana 71135-1000  
Shipping Address: 8700 Line Avenue, Shreveport, Louisiana 71106  
TEL 1-318-865-1711  
FAX (Parts) 1-318-219-7140  
FAX (Tech Support) 1-318-219-7135  
Price: $5.00  
819-5887  
MAR 2002  
SERVICE HOTLINE  
1-800-551-8633  
PRINTED IN THE UNITED STATES  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Eizo Computer Monitor LA 120 D User Manual
ETA Systems Power Supply PD11LVSP User Manual
Exmark Lawn Mower 4500 461 User Manual
Fitness Quest Home Gym NBP01060 2 User Manual
Fluke Outdoor Timer PM6681 User Manual
Frigidaire Dishwasher FGBD2432K User Manual
Fujitsu Network Card FPCAC14A User Manual
Fundex Games Games Phase 10 Deluxe User Manual
Gefen Switch EXT HDMI13 242 User Manual
Gianni Industries Door GD 900 User Manual