Frigidaire Furnace KG7 User Manual

22/04/11  
A40  
Furnaces  
Philco KG7 Series Gas Furnace Features & Benefits  
Category IV Venting System: May be vertically or horizontally vented using either a non-direct vent (1 pipe) or direct  
vent (2 pipe) system  
100% fired and tested: All units and each component are tested on the manufacturing line  
Low boy height: Easy to apply in low ceiling applications, work well with taller high SEER coils  
Best packaging in the industry: Unique corner post design assure product will arrive to the homeowner dent free  
Tubular primary heat exchanger: Heavy gauge aluminized steel heat exchanger and stainless steel secondary heat  
exchanger assures long life  
30 second blower delay at start-up: Assures a warm duct temperature at furnace start-up. Adjustable blower settings  
(60, 90, 120 and 180 seconds)  
30 second post purge: Increases life of heat exchanger  
Hot surface igniter: Innovative application of an appliance igniter. Utilizes proven Smartlite® technology  
Color coded wire harness: Designed to fit the components, all with quick connect fittings for ease of service  
High static blowers: All models equipped with high static blowers  
90 second fixed cooling cycle blower off delay (TDR): Increases cooling performance when matched with a coil  
LP convertible: Simple burner orifice and regulator spring change for easy of convertibility  
Diagnostic lights for easy troubleshooting without counting flashes: Dedicated light for flame signal strength and 2  
lights in combination to indicate all other fault codes  
Integrated control board: Incorporates connections for electronic air clear and humidifier  
Two piece door design: Enhances furnace appearance and uses captured screw to prevent loosing door screws  
Sealed vestibule: Reduces burner and inducer sound levels  
Extended flush jacket: Jacket provides an "appliance appearance"  
CSA certified design  
115V, 60Hz. Gas connections are 1/2" NPT  
WARRANTY ON PHILCO FURNACES  
Warranty Details: Lifetime Heat Exchanger and 10 years on all parts when product is  
registered, 1 year Heat Exchanger and 1 year parts when not registered  
1 Year Comfort Quality Pledge: Replacement of the entire unit if Heat Exchanger fails within the first year  
of operation to the original owner  
Warranty Registration: Register your system within 60 days of installation  
Calgary (800) 661-1346  
(403) 244-2161  
Lethbridge (877) 595-7707  
(403) 381-7707  
Saskatoon (877) 355-3377  
(306) 933-2433  
Davies Supply Group Ltd.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
22/04/11  
A40-2  
Furnaces  
95+ AFUE Two Stage Gas Furnace (High Efficiency)  
Energy efficient brushless DC (ECM) motor  
Control board has connections for twinning  
Input Btuh  
HP -Speed-Type-FLA  
R410 Coil  
Model Number  
Part Number  
904727K  
Fixed Speed Upflow / Horizontal  
C6BAX24(C,U)B  
C6BAX30(C,U)B  
C6BAX35(C,U)B  
C6BAX36(C,U)B  
60,000  
1/2 - FS - BLDC - 6.2  
KG7TC060D24B  
C6BAX36(C,U)C  
80,000  
100,000  
120,000  
3/4 - FS - BLDC - 8.7  
3/4 - FS - BLDC - 8.7  
1.0 - FS - BLDC - 11.7  
C6BAX37(C,U)C KG7TC080D35C  
C6BAX42(C,U)C  
904728K  
904729K  
904730K  
C6BAX36(C,U)C  
C6BAX37(C,U)C KG7TC100D35C  
C6BAX42(C,U)C  
C6BAX42(C,U)D  
C6BAX48(C,U)D KG7TC120D45D  
C6BAX60(C,U)D  
Fixed Speed Downflow  
C6BAX24(C,U)B  
C6BAX30(C,U)B  
KG7TL060D24B  
C6BAX35(C,U)B  
60,000  
1/2 - FS - BLDC - 6.2  
904731K  
C6BAX36(C,U)B  
C6BAX36(C,U)C  
80,000  
100,000  
120,000  
3/4 - FS - BLDC - 8.7  
3/4 - FS - BLDC - 8.7  
1.0 - FS - BLDC - 11.7  
C6BAX37(C,U)C KG7TL080D35C  
C6BAX42(C,U)C  
904732K  
904733K  
904734K  
C6BAX36(C,U)C  
C6BAX37(C,U)C KG7TL100D35C  
C6BAX42(C,U)C  
C6BAX42(C,U)D  
C6BAX48(C,U)D KG7TL120D45D  
C6BAX60(C,U)D  
R410 Coil:  
(C=Cased, U=Uncased)  
PVC & CPVC Fittings  
Calgary (800) 661-1346  
(403) 244-2161  
Lethbridge (877) 595-7707  
(403) 381-7707  
Saskatoon (877) 355-3377  
(306) 933-2433  
Davies Supply Group Ltd.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
22/02/13  
A41  
Furnaces  
Frigidaire FG7 Series Gas Furnace Features & Benefits  
Category IV Venting System: May be vertically or horizontally vented using either a non-direct vent (1 pipe) or direct  
vent (2 pipe) system  
100% fired and tested: All units and each component are tested on the manufacturing line  
Low boy height: Easy to apply in low ceiling applications, work well with taller high SEER coils  
Best packaging in the industry: Unique corner post design assure product will arrive to the homeowner dent free  
Tubular primary heat exchanger: Heavy gauge aluminized steel heat exchanger and stainless steel secondary heat  
exchanger assure a long life  
30 second blower delay at start-up: Assures a warm duct temperature at furnace start-up. Adjustable blower settings  
(60, 90, 120 and 180 seconds)  
30 second post purge: Increases life of heat exchanger  
Hot surface igniter: Innovative application of a silicon nitride igniter. Utilizes proven Smartlite® technology  
Color coded wire harness: Designed to fit the components, all with quick connect fittings for ease of service  
High static blowers: All models equipped with high static blowers  
90 second fixed cooling cycle blower off delay (TDR): Increases cooling performance when matched with a coil  
LP convertible: Simple burner orifice and regulator spring change for easy of convertibility  
Diagnostic lights for easy troubleshooting without counting flashes: Dedicated light for flame signal strength and 2  
lights in combination to indicate all other fault codes  
Integrated control board: Incorporates connections for electronic air clear and humidifier  
Two piece door design: Enhances furnace appearance and uses captured screw to prevent loosing door screws  
Blower compartment: Sealed door to reduce air leakage and insulated for ultra quiet operation  
Sealed vestibule: Reduces burner and inducer sound levels  
Rounded corner jacket: Provides an "appliance appearance"  
CSA certified design  
115V, 60Hz. Gas connections are 1/2" NPT  
C & L are Energy Star rated  
WARRANTY ON FRIGIDAIRE FURNACES  
Warranty Details: Lifetime Heat Exchanger and 10 years on all parts when product is  
registered, 20 years Heat Exchanger and 5 year parts when not registered  
10 Year Comfort Quality Pledge: Replacement of the entire unit if Heat Exchanger fails within the first 10  
years when registered, 1 year when not registered  
Warranty Registration: Register your system within 60 days of installation  
Extended Warranty Protection: Ask your Davies Rep for specific details on labor protection plans  
Calgary (800) 661-1346  
(403) 244-2161  
Lethbridge (877) 595-7707  
(403) 381-7707  
Saskatoon (877) 355-3377  
(306) 933-2433  
Davies Supply Group Ltd.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
22/04/11  
A42  
Furnaces  
92+ AFUE Single Stage Gas Furnace (High Efficiency)  
Multi-speed direct drive blower designed to give a wide range of cooling capacities  
Switches on PCB, provide ultra easy motor speed selection  
Input Btuh  
HP -Speed-Type-FLA  
R410 Coil  
Model Number  
Part Number  
Upflow / Horizontal  
C6BAX24(C,U)A  
C6BAX30(C,U)A  
38,000  
54,000  
1/3 - 4 - PSC - 4.80  
1/2 - 4 - PSC - 8.20  
FG7SC038D23A  
FG7SC054D24B  
904639F  
904640F  
C6BAX24(C,U)B  
C6BAX30(C,U)B  
C6BAX35(C,U)B  
C6BAX36(C,U)B  
C6BAX24(C,U)B  
C6BAX30(C,U)B  
C6BAX35(C,U)B  
C6BAX36(C,U)B  
72,000  
1/2 - 4 - PSC - 8.20  
FG7SC072D24B  
904641F  
C6BAX36(C,U)C  
72,000  
90,000  
1/2 - 4 - PSC - 7.50  
1.0 - 4 - PSC - 13.75  
1.0 - 4 - PSC - 13.75  
1.0 - 4 - PSC - 13.75  
C6BAX37(C,U)C FG7SC072D35C  
C6BAX42(C,U)C  
904642F  
904643F  
904644F  
904645F  
C6BAX36(C,U)C  
C6BAX37(C,U)C FG7SC090D35C  
C6BAX42(C,U)C  
C6BAX42(C,U)D  
C6BAX48(C,U)D FG7SC108D45D  
C6BAX60(C,U)D  
108,000  
120,000  
C6BAX42(C,U)D  
C6BAX48(C,U)D FG7SC120D45D  
C6BAX60(C,U)D  
Downflow  
C6BAX24(C,U)B  
C6BAX30(C,U)B  
FG7SL054D24B  
C6BAX35(C,U)B  
C6BAX36(C,U)B  
54,000  
72,000  
1/2 - 4 - PSC - 8.20  
1/2 - 4 - PSC - 8.20  
904651F  
904652F  
C6BAX24(C,U)B  
C6BAX30(C,U)B  
FG7SL072D24B  
C6BAX35(C,U)B  
C6BAX36(C,U)B  
C6BAX36(C,U)C  
90,000  
1.0 - 4 - PSC - 7.50  
1.0 - 4 - PSC - 13.75  
C6BAX37(C,U)C FG7SL090D35C  
C6BAX42(C,U)C  
904653F  
904654F  
C6BAX42(C,U)D  
C6BAX48(C,U)D FG7SL120D45D  
C6BAX60(C,U)D  
120,000  
R410 Coil:  
(C=Cased, U=Uncased)  
PVC & CPVC Fittings  
Calgary (800) 661-1346  
(403) 244-2161  
Lethbridge (877) 595-7707  
(403) 381-7707  
Saskatoon (877) 355-3377  
(306) 933-2433  
Davies Supply Group Ltd.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
22/04/11  
A43  
Furnaces  
95+ AFUE Two Stage Gas Furnace (High Efficiency)  
iSEER energy efficient brushless DC (ECM) motor gives up to 1 SEER point  
efficiency gain in cooling  
Two stage inducer optimizes efficiency on first stage heat and reduces sound levels  
Input Btuh  
HP -Speed-Type-FLA  
R410 Coil  
Model Number  
Part Number  
Fixed Speed Upflow / Horizontal  
C6BAX24(C,U)B  
C6BAX30(C,U)B  
C6BAX35(C,U)B  
C6BAX36(C,U)B  
60,000  
1/2 - FS - BLDC - 6.2  
FG7TC060D24B  
904727F  
C6BAX36(C,U)C  
C6BAX37(C,U)C  
C6BAX42(C,U)C  
80,000  
100,000  
120,000  
3/4 - FS - BLDC - 8.7  
3/4 - FS - BLDC - 8.7  
1.0 - FS - BLDC - 11.7  
FG7TC080D35C  
FG7TC100D35C  
FG7TC120D45D  
904728F  
904729F  
904730F  
C6BAX36(C,U)C  
C6BAX37(C,U)C  
C6BAX42(C,U)C  
C6BAX42(C,U)D  
C6BAX48(C,U)D  
C6BAX60(C,U)D  
Variable Speed Upflow / Horizontal  
C6BAX24(C,U)B  
C6BAX30(C,U)B  
C6BAX35(C,U)B  
C6BAX36(C,U)B  
60,000  
1/2 - VS - 6.2  
FG7TC060DVB  
904735F  
C6BAX36(C,U)C  
C6BAX37(C,U)C  
C6BAX42(C,U)C  
80,000  
100,000  
120,000  
3/4 - VS - 8.7  
3/4 - VS - 8.7  
1.0 - VS - 11.7  
FG7TC080DVC  
FG7TC0100DVC  
FG7TC120DVD  
904736F  
904737F  
904738F  
C6BAX36(C,U)C  
C6BAX37(C,U)C  
C6BAX42(C,U)C  
C6BAX42(C,U)D  
C6BAX48(C,U)D  
C6BAX60(C,U)D  
R410 Coil:  
(C=Cased, U=Uncased)  
PVC & CPVC Fittings  
Calgary (800) 661-1346  
(403) 244-2161  
Lethbridge (877) 595-7707  
(403) 381-7707  
Saskatoon (877) 355-3377  
(306) 933-2433  
Davies Supply Group Ltd.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
22/04/11  
A44  
Furnaces  
97+ AFUE iQ Drive® Modulating Gas Furnace (Ultra High Efficiency)  
iQ Drive® Modulating Heating Operation Includes:  
- Modulating gas valve from 100% to 50% input in 5% increments  
- Time proportioning modulation down to 15%  
- Variable speed inducer and blower  
iQ Drive® thermostat provides modulation down to 15% and is required for furnace  
operation  
iSEER energy efficient brushless DC (ECM) motor gives up to 1 SEER point  
efficiency gain in cooling  
Input Btuh  
HP -Speed-FLA  
R410 Coil  
Model Number  
Part Number  
904743F  
Fully Modulating, Variable Speed Upflow / Horizontal  
C6BAX24(C,U)B  
C6BAX30(C,U)B  
C6BAX35(C,U)B  
C6BAX36(C,U)B  
60,000  
1/2 - Variable - 6.2  
FG7MQ060DVB  
C6BAX36(C,U)C  
C6BAX37(C,U)C  
C6BAX42(C,U)C  
80,000  
100,000  
120,000  
3/4 - Variable - 8.7  
3/4 - Variable - 8.7  
1.0 - Variable - 11.7  
FG7MQ080DVC  
FG7MQ100DVC  
FG7MQ120DVD  
904744F  
904745F  
904746F  
C6BAX36(C,U)C  
C6BAX37(C,U)C  
C6BAX42(C,U)C  
C6BAX42(C,U)D  
C6BAX48(C,U)D  
C6BAX60(C,U)D  
R410 Coil:  
(C=Cased, U=Uncased)  
iQ Drive® Controller & Accessories  
Customizable programming options for every day, weekdays, weekends or individ-  
ual days  
On-board diagnostics alert when service or maintenance is needed  
Smart recovery gradually adjusts indoor temperatures for greater comfort  
Senses humidity and has a dehumidification mode that removes moisture quickly  
Communicates to various components within the iQ Drive® System and serves as  
the main controller for an iQ Zone® System  
Auto changeover automatically switches the thermostat from heating to cooling  
No batteries required, settings are stored internally in the event of a power failure  
Two color backlight for easy viewing  
Energy saving features are customizable (temperature setbacks, heat pump/electric  
heat or furnace changeover)  
IMPORTANT:  
The iQ Drive® Furnace  
must be controlled by the  
iQ Drive® Controller.  
This Controller requires  
18-22 gauge stranded  
wire with a grounded  
shield when connecting  
to furnace.  
Description  
iQ Drive® Controller - Complete System Monitor & Controller  
Accessories  
Part Number  
920621F  
Individually Shielded Wire, 30m (100')  
2 Pair, 4 Conductor, 22 AWG Stranded (7x30) TC Conductors, 300V RMS 60ºC  
B8723  
Optional Outdoor Sensor  
920938  
PVC & CPVC Fittings  
Calgary (800) 661-1346  
(403) 244-2161  
Lethbridge (877) 595-7707  
(403) 381-7707  
Saskatoon (877) 355-3377  
(306) 933-2433  
Davies Supply Group Ltd.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
31/12/10  
A45  
Furnaces  
Floor Registers - Plastic  
Sleek modern look with rounded corners and blades  
Durable plastic construction, will not rust  
Smooth, quiet damper adjustment for desired level of air flow  
Easy to install, maintenance free  
Description  
Brand  
Part Number  
RF31003B  
RF31028B  
RF31036B  
RF41003B  
RF41028B  
RF41036B  
3"x10" Register - White  
3"x10" Register - Taupe  
3"x10" Register - Brown  
4"x10" Register - White  
4"x10" Register - Taupe  
4"x10" Register - Brown  
Deflecto  
Deflecto  
Deflecto  
Deflecto  
Deflecto  
Deflecto  
Horizontal Conversion Kit for Frigidaire "G6" Gas Furnaces  
For converting a 90+ upflow residential gas furnace to a horizontal  
left or horizontal right position  
Kit Includes  
Brand  
Part Number  
Installation Instructions (#707796)  
1/2" barbed fitting (#663841)  
2" to 1/2" PVC reducer bushing (#663840)  
2" PVC tee (#663115)  
Tube, drain hard "J" - 5" x 2" (#663763)  
Tube, soft - 10" (#663764)  
Tube, soft - 50" (#663765)  
Frigidaire  
903568  
Tube, high temp, grey - 17.5" (#263965)  
Vinyl cap - 5/8" (#663723)  
Vinyl cap - 1/2" (#663684)  
Hose clamps (2) - 7/8" dia. (#668914)  
Reducer - 3" to 2" (#663692)  
Horizontal installation suspended in attic or crawl space  
Filter Rack  
Comes with door  
Filter Size  
16" x 25" x 1"  
20" x 25" x 1"  
Part Number  
FR16251  
FR20251  
Calgary (800) 661-1346  
(403) 244-2161  
Lethbridge (877) 595-7707  
(403) 381-7707  
Saskatoon (877) 355-3377  
(306) 933-2433  
Davies Supply Group Ltd.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
15/02/13  
A45-1  
Furnace Accessories  
LP Gas Conversion Kits  
For G6 & L1 Series Furnaces  
Designed for Canadian installations. To convert a natural gas  
furnace to LP/Propane gas for altitudes between 0 to 4,500  
feet above sea level, the main gas orifice must be replaced.  
For higher altitudes (between 2,000 & 4,500 feet above seal  
level) the input must be de-rated by 10%. This can be done  
by simply reducing the manifold pressure without changing  
the gas orifices.  
Use on standard & slow opening models only  
Not for use with step regulator valves  
Part  
Number  
Application  
Brand  
For use with G6 & L1 series gas furnaces using a  
Honeywell Gas Valve  
Frigidaire  
904091A  
For G7 Series Furnaces  
Designed for Canadian installations to convert a natural gas  
furnace to LP/Propane gas. Used for altitudes between 0 to  
4,500 feet above sea level  
For altitudes between 0 and 1,999 feet, only the orifice needs  
to be changed. For altitudes between 2,000 and 4,500 feet,  
both the orifice and the regulator pressure need to be  
changed.  
Part  
Number  
Application  
Brand  
For use with G7 series gas furnaces using a  
Honeywell Gas Valve  
Frigidaire  
904915  
For G7MQ Modulating Furnaces  
Application  
Part  
Number  
Brand  
For use with G7MQ series gas furnaces  
Frigidaire  
904950  
Calgary (800) 661-1346  
(403) 244-2161  
Lethbridge (877) 595-7707  
(403) 381-7707  
Saskatoon (877) 355-3377  
(306) 933-2433  
Davies Supply Group Ltd.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
15/02/13  
A45-2  
Furnaces  
This Page Left  
Intentionally  
Blank  
Calgary (800) 661-1346  
(403) 244-2161  
Lethbridge (877) 595-7707  
(403) 381-7707  
Saskatoon (877) 355-3377  
(306) 933-2433  
Davies Supply Group Ltd.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
14/12/12  
A45-3  
Furnaces  
Flue Gas Venting System - System 636™ PVC  
Type BH Class IIA Vent: For use with gas fired appliances producing flue gases of 65oC or less  
Complete system fully certified to ULC S636  
White pipe with unique blue certification markings made to SCH 40 dimensions  
Description  
Case Part Number  
Concentric Vent Kits  
These "pipe-in-pipe" kits allow for both exhaust and intake pipes to  
penetrate the roof or side wall through only one hole and are  
certified with mechanically fastened rain caps  
Screw/bolt assembly (included) for mechanically fastening the rain  
cap can be easily removed for cleaning or maintenance  
2" Flue Gas Venting System  
2" Concentric Vent Termination Kit (no vent screen)  
2" Wall Termination Kit (no vent screen)  
2" x 10' Pipe (Straight End)  
3
1
196005  
081216  
194000  
196352  
196242  
196232  
196122  
196022  
196082  
Wall Termination Kits  
10  
70  
110  
60  
55  
40  
35  
For a traditional vent style, IPEX’s PVC Wall Termination Vent Kits  
require only two small wall penetrations for intake and exhaust.  
Kits include a white finishing plate with a self sealing foam back  
that can be screwed to the exterior wall.  
2" Coupling (HubxHub)  
2" 45o Elbow (HubxHub)  
2" 90o Street Elbow (SPxHub)  
Testing Plug & Bushing Kit  
Allows an inline access point for flue monitoring using fully certified  
System 636 components. The kit consists of a 2" x 1/2" reducer  
bushing (Spig x FPT) and a removable 1/2" MPT plug.  
May be installed in new installations or added to existing lines  
when monitoring is required  
Bushing must be inserted in a 2" fitting socket  
May be used on vent lines in any diameter  
2" 90o Long Elbow (HubxHub)  
2" 90o Extra Long Elbow (HubxHub)  
2" Sanitary Tee (HubxHubxHub)  
3" Flue Gas Venting System  
3" Concentric Vent Termination Kit (no vent screen)  
3" Wall Termination Kit (no vent screen)  
3" x 10' Pipe (Straight End)  
3
196006  
081219  
194001  
196353  
196243  
196233  
196123  
196023  
196083  
Certified for use only on IPEX System 636 flue gas vent lines.  
1
10  
60  
25  
15  
23  
15  
17  
Concentric Vent Kit  
3" Coupling (HubxHub)  
3" 45o Elbow (HubxHub)  
3" 90o Street Elbow (SPxHub)  
3" 90o Long Elbow (HubxHub)  
3" 90o Extra Long Elbow (HubxHub)  
3" Sanitary Tee (HubxHubxHub)  
Adapters & Other Components  
3" x 2" Increaser Coupling (HubxHub)  
3" x 2" Reducer Tee (HubxHubxHub)  
Wall  
Termination  
Kit  
Testing Plug  
& Bushing  
Kit  
45  
10  
196364  
196822  
2" x 1 1/2" Reducer Bushing (SPxHub)  
Used with #196278  
80  
196282  
1 1/2" x 1/2" Reducer Busing (SPxHose Barb)  
2" Testing Plug & Bushing Kit (SPxPlug)  
Cement  
80  
10  
196278  
196143  
PVC Cement, Low VOC (1 pint/473ml)  
PVC Cement, Low VOC (1 quart/946ml)  
Transition Cement - To ABS Only (1 pint/473ml)  
Primer  
12  
12  
12  
196040  
196041  
196044  
Primer should be used when installing System636 products at temperatures  
below 0oC  
PVC/CPVC Purple Primer, Low VOC (1 pint/473ml)  
PVC/CPVC Clear Primer, Low VOC (1 pint/473ml)  
PVC/CPVC Purple Primer, Low VOC (1qt/946ml)  
12  
12  
12  
196042  
196017  
196043  
NOTES:  
1. Do Not interchange pipe, fittings or chemicals from different BH vent manufactures. Doing so will  
void System636™ product certification and warranty.  
2. Contractors must check local codes for proper venting  
Calgary (800) 661-1346  
(403) 244-2161  
Lethbridge (877) 595-7707  
(403) 381-7707  
Saskatoon (877) 355-3377  
(306) 933-2433  
Davies Supply Group Ltd.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
14/12/12  
A45-4  
Furnaces  
Condensate Water Neutralizer Kit For High Efficient Gas Furnaces  
Inline cartridge that will raise or neutralize the pH level of the  
condensate water  
Limestone neutralizer material should be changed yearly  
Description  
Includes  
Part Number  
902377  
2" Inline cartridge 1/2" ID vinyl tubing, hose clamps & mounting ties  
J Hooks (Furnace Venting Accessory)  
Description  
Part Number  
515-J2000  
2" x 7 1/2" DWV Swiveling J Hook (Plastic)  
3" x 7 1/2" DWV Swiveling J Hook (Plastic)  
515-J3000  
Calgary (800) 661-1346  
(403) 244-2161  
Lethbridge (877) 595-7707  
(403) 381-7707  
Saskatoon (877) 355-3377  
(306) 933-2433  
Davies Supply Group Ltd.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
11/06/10  
A45-5  
Furnaces  
Variable Speed Blower Kits for Frigidaire "G6 & L1" Gas Furnaces  
904231 kit fits all G6/L1 series gas furnaces with an "A" width  
cabinet. May be configured for air conditioning/heat pump airflows  
from 1 1/2 to 3 tons nominal capacity.  
904075 kit fits all G6 (RA,RC,RK&RL) series gas furnaces with "B"  
& "C" width cabinets. May be field configured for air conditioning/  
heat pump airflows from 2 to 5 tons nominal capacity.  
Designed to maximize system efficiencies, improve air quality and  
reduce sound levels  
Air conditioning and heat pump efficiencies up to 16 SEER and 8.5  
HSPF  
ECM (electronically commutated motor) variable speed DC motor  
allows for 12 selected cooling airflows and 8 heating airflows to  
match any applications  
Extra low speed for "fan only" operation  
Extra quiet and smooth blower on and off cycles  
Warranty: Carries the balance of original equipment warranty  
Description  
Part Number  
904231  
Fits "A" Width Cabinets for G6 & L1 series  
WARNING  
Not for use with Model Numbers:  
*G6RK096-12B & *GF1RK096-12B  
Fits "B" & "C" Width Cabinets for G6: RA,RC,RK,RL series  
(not suitable for "B" cabinet 1200 CFM applications)  
904075  
Specifications  
904231  
904075  
11" x 10"  
3/4  
10" x 6"  
1/2  
Nominal Blower Size  
Maximum Motor HP  
Programmable  
Variable Speed  
Programmable  
Variable Speed  
Motor Type  
720 to 1240  
550 to 1215  
720 to 1870  
720 to 1800  
Cooling CFM Range*  
Heating Airflow Range*  
* Airflow is held constant regardless of external static pressure within the HP and RPM  
limits of the motor  
Variable Speed Motor Tester - TECMate PRO™  
Designed to assist field service technicians by troubleshooting GE  
ECM 2.3 motors independently of the HVAC system  
Description  
Part Number  
904232  
TECMate Pro™ Variable Speed Motor Tester  
Twinning Kit For G7 Single Stage Gas Furnaces  
Provides the capability to combine the operation of two single stage  
gas furnaces with PSC motors (not for use with 2 stage, modulating or  
variable speed blower models)  
Twinning function not backwards compatible with furnaces manufac-  
tured prior to June 2009  
Description  
Part Number  
G7 Twinning Kit For Single Stage Gas Furnaces Manufactured After  
June 2009  
920919  
Calgary (800) 661-1346  
(403) 244-2161  
Lethbridge (877) 595-7707  
(403) 381-7707  
Saskatoon (877) 355-3377  
(306) 933-2433  
Davies Supply Group Ltd.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
06/09/13  
A45-6  
Furnaces  
This Page Left  
Intentionally  
Blank  
Calgary (800) 661-1346  
(403) 244-2161  
Lethbridge (877) 595-7707  
(403) 381-7707  
Saskatoon (877) 355-3377  
(306) 933-2433  
Davies Supply Group Ltd.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
18/02/11  
A45-7  
Furnaces  
Oil-Fired Forced Air Furnaces With Burner  
80+ AFUE  
Warranty: Limited lifetime on 14 gauge heat exchanger; 1 year parts  
LFR Models: Chamber-less unit is designed for compact installations requiring front or rear flue. The unit is approved  
for chimney or balanced flue venting and is ideal for electric conversions. The large filter rack can be placed on either  
side, bottom or rear  
LFR-VSM Models: With the Newmac Ultratech™ Motor Control. This system incorporates the furnace, control  
board, motor & blower. The 24VAC powered board uses a standard external HVAC transformer, is air conditioning  
ready and has LED indication and diagnostic output.  
NLF Model: For traditional replacement or new home construction requiring front flue  
NL2 Model: For traditional replacement or new home construction requiring rear flue  
NH3 Model: Vestibuled cabinet is approved for closet clearances  
All Pre & Post Purge Burners can be used with a Sealed Venting System (SVS). This system allows direct  
venting without chimneys. Required for installation: Sealed Venting Unit, Oil Flex Vent & Air Duct.  
Direct Drive Blower Motor  
Btuh  
Output  
AC Rating  
(tons)  
Part Number  
(Model Number)  
Description  
Flue  
Burner  
Brand  
HP  
Speed  
8010050-3*  
(LFR)  
Highboy  
Highboy  
Highboy  
Highboy  
Highboy  
Lowboy  
Lowboy  
Highboy  
Front / Rear  
Front / Rear  
Front / Rear  
Front / Rear  
Front / Rear  
Front  
81,000  
81,000  
81,000  
81,000  
81,000  
118,000  
77,000  
101,000  
3
3
1/3  
4
F3 Riello  
Newmac  
Newmac  
Newmac  
Newmac  
Newmac  
Newmac  
Newmac  
Newmac  
8010050-3B*  
(LFR80)  
1/3  
1/3  
1/3  
1/3  
1/2  
1/2  
1/2  
4
4
Beckett AFG  
Beckett AFG  
Pre & Post Purge  
8010050-3BP*  
(LFR)  
3
Variable  
Speed  
8010081-3B*  
(LFR-VSM)  
3
Beckett AFG  
Variable  
Speed  
Beckett AFG  
Pre & Post Purge  
8010081-3BP*  
(LFR-VSM)  
3
8010033DD-3B  
(NLF118)  
3.5  
3.5  
3
4
4
4
Beckett AFG  
Beckett AFG  
Beckett AFG  
8010027DD-3B*  
(NL2)  
Rear  
5010035  
(NH3-101)  
Top  
* Energy Star Rated  
Davies also stocks a selection  
of Beckett Burners.  
Call Davies Pros On Controls  
for proper application.  
8010050-3B (LFR)  
5010035 (NH3)  
Replacement Parts For 8010050-3B (LFR80) Furnace With Beckett AFG Burner  
Description  
Specifications  
Part Number  
21566108  
Capacity (USgal/hr): 0.50 Spray Angle: 45° - B  
Capacity (USgal/hr): 0.55 Spray Angle: 45° - B  
Bore: 1/2" Fan: 10" dia. Rotation: CW  
Hago Nozzles  
21566109  
Blower Unit (less Motor)  
2040116T  
Calgary (800) 661-1346  
(403) 244-2161  
Lethbridge (877) 595-7707  
(403) 381-7707  
Saskatoon (877) 355-3377  
(306) 933-2433  
Davies Supply Group Ltd.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
15/01/10  
A45-8  
Furnaces  
Combination Oil/Gas & Wood Furnace With Beckett AFG Burner  
Separate combustion chamber for oil/gas  
Extra large brick lined firebox  
Pre-heated combustion air is introduced by a thermostatically con-  
trolled draft system  
Disposable air filters  
Warranty: 10 year limited on the heat exchanger  
CL85/95 Model: Automatic switching from wood to oil  
CL86/96C Model: Automatic switching from wood to oil, separate  
thermostats & large fire door. Burns wood without grates for better  
control and efficiency.  
CL86/96G Model (Wood/Oil/Coal): Where wood or coal is avail-  
able, this model gives the ultimate conservation choice. Large firebox  
and firedoor with shaker grates for coal.  
Btuh  
Output  
Blower  
Motor  
Part Number  
(Model Number)  
CFM  
Brand  
8010012-2B  
(CL85/95)  
900/1000  
82,000/94,000  
86,000/ 96,000  
86,000/ 96,000  
1/3 HP  
1/3 HP  
1/3 HP  
Newmac  
Newmac  
Newmac  
8010015-2B  
(CL86/96C)  
1200/1200  
1200/1200  
8010014-2B  
(CL86/96G)  
Wood Only Furnaces  
WA0 Model: Is a wood add-on furnace designed for operation in  
conjunction with an existing residential oil furnace system with a fir-  
ing rate of .75 gph to 1.10 gph. 10 year limited warranty.  
WB100 Model: Can be used alone or in conjunction with an existing  
residential system. 10 year limited warranty on the heat exchanger.  
Btuh  
Output  
Blower  
Motor  
Part Number  
(Model Number)  
CFM  
1200  
1200  
Brand  
Newmac  
Newmac  
8010024G  
(WA0)  
100,000  
100,000  
-
8010001  
(WB100)  
1/2 HP  
8010024G  
8010001  
Calgary (800) 661-1346  
(403) 244-2161  
Lethbridge (877) 595-7707  
(403) 381-7707  
Saskatoon (877) 355-3377  
(306) 933-2433  
Davies Supply Group Ltd.  
Download from Www.Somanuals.com. All Manuals Search And Download.  

EAW Speaker SB180zP User Manual
EDGE Tech Printer QL Series User Manual
EverFocus Security Camera ED560 User Manual
Evesham Technology Laptop W810 DCX W810 U11 User Manual
Fujitsu Speaker System TD508II User Manual
GE Air Cleaner SERIES B 480 User Manual
GE Monogram GPS Receiver ZV881WSS User Manual
Gitzo Camcorder Accessories G1227G User Manual
Golden Technologies High Chair Power Lift User Manual
Goodman Mfg Air Conditioner IO 395 User Manual