22/04/11
A40
Furnaces
Philco KG7 Series Gas Furnace Features & Benefits
•
Category IV Venting System: May be vertically or horizontally vented using either a non-direct vent (1 pipe) or direct
vent (2 pipe) system
•
•
•
•
100% fired and tested: All units and each component are tested on the manufacturing line
Low boy height: Easy to apply in low ceiling applications, work well with taller high SEER coils
Best packaging in the industry: Unique corner post design assure product will arrive to the homeowner dent free
Tubular primary heat exchanger: Heavy gauge aluminized steel heat exchanger and stainless steel secondary heat
exchanger assures long life
•
30 second blower delay at start-up: Assures a warm duct temperature at furnace start-up. Adjustable blower settings
(60, 90, 120 and 180 seconds)
•
•
•
•
•
•
•
30 second post purge: Increases life of heat exchanger
Hot surface igniter: Innovative application of an appliance igniter. Utilizes proven Smartlite® technology
Color coded wire harness: Designed to fit the components, all with quick connect fittings for ease of service
High static blowers: All models equipped with high static blowers
90 second fixed cooling cycle blower off delay (TDR): Increases cooling performance when matched with a coil
LP convertible: Simple burner orifice and regulator spring change for easy of convertibility
Diagnostic lights for easy troubleshooting without counting flashes: Dedicated light for flame signal strength and 2
lights in combination to indicate all other fault codes
•
•
•
•
•
•
Integrated control board: Incorporates connections for electronic air clear and humidifier
Two piece door design: Enhances furnace appearance and uses captured screw to prevent loosing door screws
Sealed vestibule: Reduces burner and inducer sound levels
Extended flush jacket: Jacket provides an "appliance appearance"
CSA certified design
115V, 60Hz. Gas connections are 1/2" NPT
WARRANTY ON PHILCO FURNACES
Warranty Details: Lifetime Heat Exchanger and 10 years on all parts when product is
registered, 1 year Heat Exchanger and 1 year parts when not registered
1 Year Comfort Quality Pledge: Replacement of the entire unit if Heat Exchanger fails within the first year
of operation to the original owner
Warranty Registration: Register your system within 60 days of installation
Calgary (800) 661-1346
(403) 244-2161
Lethbridge (877) 595-7707
(403) 381-7707
Saskatoon (877) 355-3377
(306) 933-2433
Davies Supply Group Ltd.
Download from Www.Somanuals.com. All Manuals Search And Download.
22/04/11
A40-2
Furnaces
95+ AFUE Two Stage Gas Furnace (High Efficiency)
•
•
Energy efficient brushless DC (ECM) motor
Control board has connections for twinning
Input Btuh
HP -Speed-Type-FLA
R410 Coil
Model Number
Part Number
904727K
Fixed Speed Upflow / Horizontal
C6BAX24(C,U)B
C6BAX30(C,U)B
C6BAX35(C,U)B
C6BAX36(C,U)B
60,000
1/2 - FS - BLDC - 6.2
KG7TC060D24B
C6BAX36(C,U)C
80,000
100,000
120,000
3/4 - FS - BLDC - 8.7
3/4 - FS - BLDC - 8.7
1.0 - FS - BLDC - 11.7
C6BAX37(C,U)C KG7TC080D35C
C6BAX42(C,U)C
904728K
904729K
904730K
C6BAX36(C,U)C
C6BAX37(C,U)C KG7TC100D35C
C6BAX42(C,U)C
C6BAX42(C,U)D
C6BAX48(C,U)D KG7TC120D45D
C6BAX60(C,U)D
Fixed Speed Downflow
C6BAX24(C,U)B
C6BAX30(C,U)B
KG7TL060D24B
C6BAX35(C,U)B
60,000
1/2 - FS - BLDC - 6.2
904731K
C6BAX36(C,U)B
C6BAX36(C,U)C
80,000
100,000
120,000
3/4 - FS - BLDC - 8.7
3/4 - FS - BLDC - 8.7
1.0 - FS - BLDC - 11.7
C6BAX37(C,U)C KG7TL080D35C
C6BAX42(C,U)C
904732K
904733K
904734K
C6BAX36(C,U)C
C6BAX37(C,U)C KG7TL100D35C
C6BAX42(C,U)C
C6BAX42(C,U)D
C6BAX48(C,U)D KG7TL120D45D
C6BAX60(C,U)D
R410 Coil:
(C=Cased, U=Uncased)
PVC & CPVC Fittings
Calgary (800) 661-1346
(403) 244-2161
Lethbridge (877) 595-7707
(403) 381-7707
Saskatoon (877) 355-3377
(306) 933-2433
Davies Supply Group Ltd.
Download from Www.Somanuals.com. All Manuals Search And Download.
22/02/13
A41
Furnaces
Frigidaire FG7 Series Gas Furnace Features & Benefits
•
Category IV Venting System: May be vertically or horizontally vented using either a non-direct vent (1 pipe) or direct
vent (2 pipe) system
•
•
•
•
100% fired and tested: All units and each component are tested on the manufacturing line
Low boy height: Easy to apply in low ceiling applications, work well with taller high SEER coils
Best packaging in the industry: Unique corner post design assure product will arrive to the homeowner dent free
Tubular primary heat exchanger: Heavy gauge aluminized steel heat exchanger and stainless steel secondary heat
exchanger assure a long life
•
30 second blower delay at start-up: Assures a warm duct temperature at furnace start-up. Adjustable blower settings
(60, 90, 120 and 180 seconds)
•
•
•
•
•
•
•
30 second post purge: Increases life of heat exchanger
Hot surface igniter: Innovative application of a silicon nitride igniter. Utilizes proven Smartlite® technology
Color coded wire harness: Designed to fit the components, all with quick connect fittings for ease of service
High static blowers: All models equipped with high static blowers
90 second fixed cooling cycle blower off delay (TDR): Increases cooling performance when matched with a coil
LP convertible: Simple burner orifice and regulator spring change for easy of convertibility
Diagnostic lights for easy troubleshooting without counting flashes: Dedicated light for flame signal strength and 2
lights in combination to indicate all other fault codes
•
•
•
•
•
•
•
Integrated control board: Incorporates connections for electronic air clear and humidifier
Two piece door design: Enhances furnace appearance and uses captured screw to prevent loosing door screws
Blower compartment: Sealed door to reduce air leakage and insulated for ultra quiet operation
Sealed vestibule: Reduces burner and inducer sound levels
Rounded corner jacket: Provides an "appliance appearance"
CSA certified design
115V, 60Hz. Gas connections are 1/2" NPT
C & L are Energy Star rated
WARRANTY ON FRIGIDAIRE FURNACES
Warranty Details: Lifetime Heat Exchanger and 10 years on all parts when product is
registered, 20 years Heat Exchanger and 5 year parts when not registered
10 Year Comfort Quality Pledge: Replacement of the entire unit if Heat Exchanger fails within the first 10
years when registered, 1 year when not registered
Warranty Registration: Register your system within 60 days of installation
Extended Warranty Protection: Ask your Davies Rep for specific details on labor protection plans
Calgary (800) 661-1346
(403) 244-2161
Lethbridge (877) 595-7707
(403) 381-7707
Saskatoon (877) 355-3377
(306) 933-2433
Davies Supply Group Ltd.
Download from Www.Somanuals.com. All Manuals Search And Download.
22/04/11
A42
Furnaces
92+ AFUE Single Stage Gas Furnace (High Efficiency)
•
•
Multi-speed direct drive blower designed to give a wide range of cooling capacities
Switches on PCB, provide ultra easy motor speed selection
Input Btuh
HP -Speed-Type-FLA
R410 Coil
Model Number
Part Number
Upflow / Horizontal
C6BAX24(C,U)A
C6BAX30(C,U)A
38,000
54,000
1/3 - 4 - PSC - 4.80
1/2 - 4 - PSC - 8.20
FG7SC038D23A
FG7SC054D24B
904639F
904640F
C6BAX24(C,U)B
C6BAX30(C,U)B
C6BAX35(C,U)B
C6BAX36(C,U)B
C6BAX24(C,U)B
C6BAX30(C,U)B
C6BAX35(C,U)B
C6BAX36(C,U)B
72,000
1/2 - 4 - PSC - 8.20
FG7SC072D24B
904641F
C6BAX36(C,U)C
72,000
90,000
1/2 - 4 - PSC - 7.50
1.0 - 4 - PSC - 13.75
1.0 - 4 - PSC - 13.75
1.0 - 4 - PSC - 13.75
C6BAX37(C,U)C FG7SC072D35C
C6BAX42(C,U)C
904642F
904643F
904644F
904645F
C6BAX36(C,U)C
C6BAX37(C,U)C FG7SC090D35C
C6BAX42(C,U)C
C6BAX42(C,U)D
C6BAX48(C,U)D FG7SC108D45D
C6BAX60(C,U)D
108,000
120,000
C6BAX42(C,U)D
C6BAX48(C,U)D FG7SC120D45D
C6BAX60(C,U)D
Downflow
C6BAX24(C,U)B
C6BAX30(C,U)B
FG7SL054D24B
C6BAX35(C,U)B
C6BAX36(C,U)B
54,000
72,000
1/2 - 4 - PSC - 8.20
1/2 - 4 - PSC - 8.20
904651F
904652F
C6BAX24(C,U)B
C6BAX30(C,U)B
FG7SL072D24B
C6BAX35(C,U)B
C6BAX36(C,U)B
C6BAX36(C,U)C
90,000
1.0 - 4 - PSC - 7.50
1.0 - 4 - PSC - 13.75
C6BAX37(C,U)C FG7SL090D35C
C6BAX42(C,U)C
904653F
904654F
C6BAX42(C,U)D
C6BAX48(C,U)D FG7SL120D45D
C6BAX60(C,U)D
120,000
R410 Coil:
(C=Cased, U=Uncased)
PVC & CPVC Fittings
Calgary (800) 661-1346
(403) 244-2161
Lethbridge (877) 595-7707
(403) 381-7707
Saskatoon (877) 355-3377
(306) 933-2433
Davies Supply Group Ltd.
Download from Www.Somanuals.com. All Manuals Search And Download.
22/04/11
A43
Furnaces
95+ AFUE Two Stage Gas Furnace (High Efficiency)
•
iSEER energy efficient brushless DC (ECM) motor gives up to 1 SEER point
efficiency gain in cooling
Two stage inducer optimizes efficiency on first stage heat and reduces sound levels
•
Input Btuh
HP -Speed-Type-FLA
R410 Coil
Model Number
Part Number
Fixed Speed Upflow / Horizontal
C6BAX24(C,U)B
C6BAX30(C,U)B
C6BAX35(C,U)B
C6BAX36(C,U)B
60,000
1/2 - FS - BLDC - 6.2
FG7TC060D24B
904727F
C6BAX36(C,U)C
C6BAX37(C,U)C
C6BAX42(C,U)C
80,000
100,000
120,000
3/4 - FS - BLDC - 8.7
3/4 - FS - BLDC - 8.7
1.0 - FS - BLDC - 11.7
FG7TC080D35C
FG7TC100D35C
FG7TC120D45D
904728F
904729F
904730F
C6BAX36(C,U)C
C6BAX37(C,U)C
C6BAX42(C,U)C
C6BAX42(C,U)D
C6BAX48(C,U)D
C6BAX60(C,U)D
Variable Speed Upflow / Horizontal
C6BAX24(C,U)B
C6BAX30(C,U)B
C6BAX35(C,U)B
C6BAX36(C,U)B
60,000
1/2 - VS - 6.2
FG7TC060DVB
904735F
C6BAX36(C,U)C
C6BAX37(C,U)C
C6BAX42(C,U)C
80,000
100,000
120,000
3/4 - VS - 8.7
3/4 - VS - 8.7
1.0 - VS - 11.7
FG7TC080DVC
FG7TC0100DVC
FG7TC120DVD
904736F
904737F
904738F
C6BAX36(C,U)C
C6BAX37(C,U)C
C6BAX42(C,U)C
C6BAX42(C,U)D
C6BAX48(C,U)D
C6BAX60(C,U)D
R410 Coil:
(C=Cased, U=Uncased)
PVC & CPVC Fittings
Calgary (800) 661-1346
(403) 244-2161
Lethbridge (877) 595-7707
(403) 381-7707
Saskatoon (877) 355-3377
(306) 933-2433
Davies Supply Group Ltd.
Download from Www.Somanuals.com. All Manuals Search And Download.
22/04/11
A44
Furnaces
97+ AFUE iQ Drive® Modulating Gas Furnace (Ultra High Efficiency)
•
iQ Drive® Modulating Heating Operation Includes:
- Modulating gas valve from 100% to 50% input in 5% increments
- Time proportioning modulation down to 15%
- Variable speed inducer and blower
•
•
iQ Drive® thermostat provides modulation down to 15% and is required for furnace
operation
iSEER energy efficient brushless DC (ECM) motor gives up to 1 SEER point
efficiency gain in cooling
Input Btuh
HP -Speed-FLA
R410 Coil
Model Number
Part Number
904743F
Fully Modulating, Variable Speed Upflow / Horizontal
C6BAX24(C,U)B
C6BAX30(C,U)B
C6BAX35(C,U)B
C6BAX36(C,U)B
60,000
1/2 - Variable - 6.2
FG7MQ060DVB
C6BAX36(C,U)C
C6BAX37(C,U)C
C6BAX42(C,U)C
80,000
100,000
120,000
3/4 - Variable - 8.7
3/4 - Variable - 8.7
1.0 - Variable - 11.7
FG7MQ080DVC
FG7MQ100DVC
FG7MQ120DVD
904744F
904745F
904746F
C6BAX36(C,U)C
C6BAX37(C,U)C
C6BAX42(C,U)C
C6BAX42(C,U)D
C6BAX48(C,U)D
C6BAX60(C,U)D
R410 Coil:
(C=Cased, U=Uncased)
iQ Drive® Controller & Accessories
•
Customizable programming options for every day, weekdays, weekends or individ-
ual days
•
•
•
•
On-board diagnostics alert when service or maintenance is needed
Smart recovery gradually adjusts indoor temperatures for greater comfort
Senses humidity and has a dehumidification mode that removes moisture quickly
Communicates to various components within the iQ Drive® System and serves as
the main controller for an iQ Zone® System
•
•
•
•
Auto changeover automatically switches the thermostat from heating to cooling
No batteries required, settings are stored internally in the event of a power failure
Two color backlight for easy viewing
Energy saving features are customizable (temperature setbacks, heat pump/electric
heat or furnace changeover)
IMPORTANT:
The iQ Drive® Furnace
must be controlled by the
iQ Drive® Controller.
This Controller requires
18-22 gauge stranded
wire with a grounded
shield when connecting
to furnace.
Description
iQ Drive® Controller - Complete System Monitor & Controller
Accessories
Part Number
920621F
Individually Shielded Wire, 30m (100')
2 Pair, 4 Conductor, 22 AWG Stranded (7x30) TC Conductors, 300V RMS 60ºC
B8723
Optional Outdoor Sensor
920938
PVC & CPVC Fittings
Calgary (800) 661-1346
(403) 244-2161
Lethbridge (877) 595-7707
(403) 381-7707
Saskatoon (877) 355-3377
(306) 933-2433
Davies Supply Group Ltd.
Download from Www.Somanuals.com. All Manuals Search And Download.
31/12/10
A45
Furnaces
Floor Registers - Plastic
•
•
•
•
Sleek modern look with rounded corners and blades
Durable plastic construction, will not rust
Smooth, quiet damper adjustment for desired level of air flow
Easy to install, maintenance free
Description
Brand
Part Number
RF31003B
RF31028B
RF31036B
RF41003B
RF41028B
RF41036B
3"x10" Register - White
3"x10" Register - Taupe
3"x10" Register - Brown
4"x10" Register - White
4"x10" Register - Taupe
4"x10" Register - Brown
Deflecto
Deflecto
Deflecto
Deflecto
Deflecto
Deflecto
Horizontal Conversion Kit for Frigidaire "G6" Gas Furnaces
•
For converting a 90+ upflow residential gas furnace to a horizontal
left or horizontal right position
Kit Includes
Brand
Part Number
Installation Instructions (#707796)
1/2" barbed fitting (#663841)
2" to 1/2" PVC reducer bushing (#663840)
2" PVC tee (#663115)
Tube, drain hard "J" - 5" x 2" (#663763)
Tube, soft - 10" (#663764)
Tube, soft - 50" (#663765)
Frigidaire
903568
Tube, high temp, grey - 17.5" (#263965)
Vinyl cap - 5/8" (#663723)
Vinyl cap - 1/2" (#663684)
Hose clamps (2) - 7/8" dia. (#668914)
Reducer - 3" to 2" (#663692)
Horizontal installation suspended in attic or crawl space
Filter Rack
•
Comes with door
Filter Size
16" x 25" x 1"
20" x 25" x 1"
Part Number
FR16251
FR20251
Calgary (800) 661-1346
(403) 244-2161
Lethbridge (877) 595-7707
(403) 381-7707
Saskatoon (877) 355-3377
(306) 933-2433
Davies Supply Group Ltd.
Download from Www.Somanuals.com. All Manuals Search And Download.
15/02/13
A45-1
Furnace Accessories
LP Gas Conversion Kits
For G6 & L1 Series Furnaces
•
Designed for Canadian installations. To convert a natural gas
furnace to LP/Propane gas for altitudes between 0 to 4,500
feet above sea level, the main gas orifice must be replaced.
For higher altitudes (between 2,000 & 4,500 feet above seal
level) the input must be de-rated by 10%. This can be done
by simply reducing the manifold pressure without changing
the gas orifices.
•
•
Use on standard & slow opening models only
Not for use with step regulator valves
Part
Number
Application
Brand
For use with G6 & L1 series gas furnaces using a
Honeywell Gas Valve
Frigidaire
904091A
For G7 Series Furnaces
•
Designed for Canadian installations to convert a natural gas
furnace to LP/Propane gas. Used for altitudes between 0 to
4,500 feet above sea level
•
For altitudes between 0 and 1,999 feet, only the orifice needs
to be changed. For altitudes between 2,000 and 4,500 feet,
both the orifice and the regulator pressure need to be
changed.
Part
Number
Application
Brand
For use with G7 series gas furnaces using a
Honeywell Gas Valve
Frigidaire
904915
For G7MQ Modulating Furnaces
Application
Part
Number
Brand
For use with G7MQ series gas furnaces
Frigidaire
904950
Calgary (800) 661-1346
(403) 244-2161
Lethbridge (877) 595-7707
(403) 381-7707
Saskatoon (877) 355-3377
(306) 933-2433
Davies Supply Group Ltd.
Download from Www.Somanuals.com. All Manuals Search And Download.
15/02/13
A45-2
Furnaces
This Page Left
Intentionally
Blank
Calgary (800) 661-1346
(403) 244-2161
Lethbridge (877) 595-7707
(403) 381-7707
Saskatoon (877) 355-3377
(306) 933-2433
Davies Supply Group Ltd.
Download from Www.Somanuals.com. All Manuals Search And Download.
14/12/12
A45-3
Furnaces
Flue Gas Venting System - System 636™ PVC
•
•
•
Type BH Class IIA Vent: For use with gas fired appliances producing flue gases of 65oC or less
Complete system fully certified to ULC S636
White pipe with unique blue certification markings made to SCH 40 dimensions
Description
Case Part Number
Concentric Vent Kits
•
These "pipe-in-pipe" kits allow for both exhaust and intake pipes to
penetrate the roof or side wall through only one hole and are
certified with mechanically fastened rain caps
Screw/bolt assembly (included) for mechanically fastening the rain
cap can be easily removed for cleaning or maintenance
2" Flue Gas Venting System
2" Concentric Vent Termination Kit (no vent screen)
2" Wall Termination Kit (no vent screen)
2" x 10' Pipe (Straight End)
3
1
196005
081216
194000
196352
196242
196232
196122
196022
196082
•
Wall Termination Kits
•
10
70
110
60
55
40
35
For a traditional vent style, IPEX’s PVC Wall Termination Vent Kits
require only two small wall penetrations for intake and exhaust.
Kits include a white finishing plate with a self sealing foam back
that can be screwed to the exterior wall.
2" Coupling (HubxHub)
2" 45o Elbow (HubxHub)
•
2" 90o Street Elbow (SPxHub)
Testing Plug & Bushing Kit
•
Allows an inline access point for flue monitoring using fully certified
System 636 components. The kit consists of a 2" x 1/2" reducer
bushing (Spig x FPT) and a removable 1/2" MPT plug.
May be installed in new installations or added to existing lines
when monitoring is required
Bushing must be inserted in a 2" fitting socket
May be used on vent lines in any diameter
2" 90o Long Elbow (HubxHub)
2" 90o Extra Long Elbow (HubxHub)
2" Sanitary Tee (HubxHubxHub)
3" Flue Gas Venting System
•
•
•
•
3" Concentric Vent Termination Kit (no vent screen)
3" Wall Termination Kit (no vent screen)
3" x 10' Pipe (Straight End)
3
196006
081219
194001
196353
196243
196233
196123
196023
196083
Certified for use only on IPEX System 636 flue gas vent lines.
1
10
60
25
15
23
15
17
Concentric Vent Kit
3" Coupling (HubxHub)
3" 45o Elbow (HubxHub)
3" 90o Street Elbow (SPxHub)
3" 90o Long Elbow (HubxHub)
3" 90o Extra Long Elbow (HubxHub)
3" Sanitary Tee (HubxHubxHub)
Adapters & Other Components
3" x 2" Increaser Coupling (HubxHub)
3" x 2" Reducer Tee (HubxHubxHub)
Wall
Termination
Kit
Testing Plug
& Bushing
Kit
45
10
196364
196822
2" x 1 1/2" Reducer Bushing (SPxHub)
Used with #196278
80
196282
1 1/2" x 1/2" Reducer Busing (SPxHose Barb)
2" Testing Plug & Bushing Kit (SPxPlug)
Cement
80
10
196278
196143
PVC Cement, Low VOC (1 pint/473ml)
PVC Cement, Low VOC (1 quart/946ml)
Transition Cement - To ABS Only (1 pint/473ml)
Primer
12
12
12
196040
196041
196044
Primer should be used when installing System636 products at temperatures
below 0oC
PVC/CPVC Purple Primer, Low VOC (1 pint/473ml)
PVC/CPVC Clear Primer, Low VOC (1 pint/473ml)
PVC/CPVC Purple Primer, Low VOC (1qt/946ml)
12
12
12
196042
196017
196043
NOTES:
1. Do Not interchange pipe, fittings or chemicals from different BH vent manufactures. Doing so will
void System636™ product certification and warranty.
2. Contractors must check local codes for proper venting
Calgary (800) 661-1346
(403) 244-2161
Lethbridge (877) 595-7707
(403) 381-7707
Saskatoon (877) 355-3377
(306) 933-2433
Davies Supply Group Ltd.
Download from Www.Somanuals.com. All Manuals Search And Download.
14/12/12
A45-4
Furnaces
Condensate Water Neutralizer Kit For High Efficient Gas Furnaces
•
Inline cartridge that will raise or neutralize the pH level of the
condensate water
Limestone neutralizer material should be changed yearly
•
Description
Includes
Part Number
902377
2" Inline cartridge 1/2" ID vinyl tubing, hose clamps & mounting ties
J Hooks (Furnace Venting Accessory)
Description
Part Number
515-J2000
2" x 7 1/2" DWV Swiveling J Hook (Plastic)
3" x 7 1/2" DWV Swiveling J Hook (Plastic)
515-J3000
Calgary (800) 661-1346
(403) 244-2161
Lethbridge (877) 595-7707
(403) 381-7707
Saskatoon (877) 355-3377
(306) 933-2433
Davies Supply Group Ltd.
Download from Www.Somanuals.com. All Manuals Search And Download.
11/06/10
A45-5
Furnaces
Variable Speed Blower Kits for Frigidaire "G6 & L1" Gas Furnaces
•
904231 kit fits all G6/L1 series gas furnaces with an "A" width
cabinet. May be configured for air conditioning/heat pump airflows
from 1 1/2 to 3 tons nominal capacity.
•
904075 kit fits all G6 (RA,RC,RK&RL) series gas furnaces with "B"
& "C" width cabinets. May be field configured for air conditioning/
heat pump airflows from 2 to 5 tons nominal capacity.
Designed to maximize system efficiencies, improve air quality and
reduce sound levels
Air conditioning and heat pump efficiencies up to 16 SEER and 8.5
HSPF
ECM (electronically commutated motor) variable speed DC motor
allows for 12 selected cooling airflows and 8 heating airflows to
match any applications
•
•
•
•
•
•
Extra low speed for "fan only" operation
Extra quiet and smooth blower on and off cycles
Warranty: Carries the balance of original equipment warranty
Description
Part Number
904231
Fits "A" Width Cabinets for G6 & L1 series
WARNING
Not for use with Model Numbers:
*G6RK096-12B & *GF1RK096-12B
Fits "B" & "C" Width Cabinets for G6: RA,RC,RK,RL series
(not suitable for "B" cabinet 1200 CFM applications)
904075
Specifications
904231
904075
11" x 10"
3/4
10" x 6"
1/2
Nominal Blower Size
Maximum Motor HP
Programmable
Variable Speed
Programmable
Variable Speed
Motor Type
720 to 1240
550 to 1215
720 to 1870
720 to 1800
Cooling CFM Range*
Heating Airflow Range*
* Airflow is held constant regardless of external static pressure within the HP and RPM
limits of the motor
Variable Speed Motor Tester - TECMate PRO™
•
Designed to assist field service technicians by troubleshooting GE
ECM 2.3 motors independently of the HVAC system
Description
Part Number
904232
TECMate Pro™ Variable Speed Motor Tester
Twinning Kit For G7 Single Stage Gas Furnaces
•
Provides the capability to combine the operation of two single stage
gas furnaces with PSC motors (not for use with 2 stage, modulating or
variable speed blower models)
•
Twinning function not backwards compatible with furnaces manufac-
tured prior to June 2009
Description
Part Number
G7 Twinning Kit For Single Stage Gas Furnaces Manufactured After
June 2009
920919
Calgary (800) 661-1346
(403) 244-2161
Lethbridge (877) 595-7707
(403) 381-7707
Saskatoon (877) 355-3377
(306) 933-2433
Davies Supply Group Ltd.
Download from Www.Somanuals.com. All Manuals Search And Download.
06/09/13
A45-6
Furnaces
This Page Left
Intentionally
Blank
Calgary (800) 661-1346
(403) 244-2161
Lethbridge (877) 595-7707
(403) 381-7707
Saskatoon (877) 355-3377
(306) 933-2433
Davies Supply Group Ltd.
Download from Www.Somanuals.com. All Manuals Search And Download.
18/02/11
A45-7
Furnaces
Oil-Fired Forced Air Furnaces With Burner
•
•
•
80+ AFUE
Warranty: Limited lifetime on 14 gauge heat exchanger; 1 year parts
LFR Models: Chamber-less unit is designed for compact installations requiring front or rear flue. The unit is approved
for chimney or balanced flue venting and is ideal for electric conversions. The large filter rack can be placed on either
side, bottom or rear
•
LFR-VSM Models: With the Newmac Ultratech™ Motor Control. This system incorporates the furnace, control
board, motor & blower. The 24VAC powered board uses a standard external HVAC transformer, is air conditioning
ready and has LED indication and diagnostic output.
•
•
•
•
NLF Model: For traditional replacement or new home construction requiring front flue
NL2 Model: For traditional replacement or new home construction requiring rear flue
NH3 Model: Vestibuled cabinet is approved for closet clearances
All Pre & Post Purge Burners can be used with a Sealed Venting System (SVS). This system allows direct
venting without chimneys. Required for installation: Sealed Venting Unit, Oil Flex Vent & Air Duct.
Direct Drive Blower Motor
Btuh
Output
AC Rating
(tons)
Part Number
(Model Number)
Description
Flue
Burner
Brand
HP
Speed
8010050-3*
(LFR)
Highboy
Highboy
Highboy
Highboy
Highboy
Lowboy
Lowboy
Highboy
Front / Rear
Front / Rear
Front / Rear
Front / Rear
Front / Rear
Front
81,000
81,000
81,000
81,000
81,000
118,000
77,000
101,000
3
3
1/3
4
F3 Riello
Newmac
Newmac
Newmac
Newmac
Newmac
Newmac
Newmac
Newmac
8010050-3B*
(LFR80)
1/3
1/3
1/3
1/3
1/2
1/2
1/2
4
4
Beckett AFG
Beckett AFG
Pre & Post Purge
8010050-3BP*
(LFR)
3
Variable
Speed
8010081-3B*
(LFR-VSM)
3
Beckett AFG
Variable
Speed
Beckett AFG
Pre & Post Purge
8010081-3BP*
(LFR-VSM)
3
8010033DD-3B
(NLF118)
3.5
3.5
3
4
4
4
Beckett AFG
Beckett AFG
Beckett AFG
8010027DD-3B*
(NL2)
Rear
5010035
(NH3-101)
Top
* Energy Star Rated
Davies also stocks a selection
of Beckett Burners.
Call Davies Pros On Controls
for proper application.
8010050-3B (LFR)
5010035 (NH3)
Replacement Parts For 8010050-3B (LFR80) Furnace With Beckett AFG Burner
Description
Specifications
Part Number
21566108
Capacity (USgal/hr): 0.50 Spray Angle: 45° - B
Capacity (USgal/hr): 0.55 Spray Angle: 45° - B
Bore: 1/2" Fan: 10" dia. Rotation: CW
Hago Nozzles
21566109
Blower Unit (less Motor)
2040116T
Calgary (800) 661-1346
(403) 244-2161
Lethbridge (877) 595-7707
(403) 381-7707
Saskatoon (877) 355-3377
(306) 933-2433
Davies Supply Group Ltd.
Download from Www.Somanuals.com. All Manuals Search And Download.
15/01/10
A45-8
Furnaces
Combination Oil/Gas & Wood Furnace With Beckett AFG Burner
•
•
•
Separate combustion chamber for oil/gas
Extra large brick lined firebox
Pre-heated combustion air is introduced by a thermostatically con-
trolled draft system
•
•
•
•
Disposable air filters
Warranty: 10 year limited on the heat exchanger
CL85/95 Model: Automatic switching from wood to oil
CL86/96C Model: Automatic switching from wood to oil, separate
thermostats & large fire door. Burns wood without grates for better
control and efficiency.
•
CL86/96G Model (Wood/Oil/Coal): Where wood or coal is avail-
able, this model gives the ultimate conservation choice. Large firebox
and firedoor with shaker grates for coal.
Btuh
Output
Blower
Motor
Part Number
(Model Number)
CFM
Brand
8010012-2B
(CL85/95)
900/1000
82,000/94,000
86,000/ 96,000
86,000/ 96,000
1/3 HP
1/3 HP
1/3 HP
Newmac
Newmac
Newmac
8010015-2B
(CL86/96C)
1200/1200
1200/1200
8010014-2B
(CL86/96G)
Wood Only Furnaces
•
•
WA0 Model: Is a wood add-on furnace designed for operation in
conjunction with an existing residential oil furnace system with a fir-
ing rate of .75 gph to 1.10 gph. 10 year limited warranty.
WB100 Model: Can be used alone or in conjunction with an existing
residential system. 10 year limited warranty on the heat exchanger.
Btuh
Output
Blower
Motor
Part Number
(Model Number)
CFM
1200
1200
Brand
Newmac
Newmac
8010024G
(WA0)
100,000
100,000
-
8010001
(WB100)
1/2 HP
8010024G
8010001
Calgary (800) 661-1346
(403) 244-2161
Lethbridge (877) 595-7707
(403) 381-7707
Saskatoon (877) 355-3377
(306) 933-2433
Davies Supply Group Ltd.