Frigidaire Cooktop FGGC3645K S W B User Manual

Built-In Cooktops  
FGGC3645K S/W/B  
36" Gas  
Product Dimensions  
Width  
Depth  
Height  
36"  
21-3/4"  
5"  
More Easy-To-Use Features  
Approved Over Frigidaire®  
Electric Wall Ovens  
Cooktops are approved for installation  
above any of our Single Electric Wall  
Ovens.  
Stainless Steel Recessed Cooktop1  
Electronic Pilotless Ignition  
LP Gas Conversion Option  
Available in:  
Stainless  
(S)  
White  
(W)  
Black  
(B)  
Burners  
BTU  
Signature Features  
Right Front  
Right Rear  
Left Front  
Left Rear  
Center  
12,000  
5,000  
9,500  
9,500  
17,000  
1Select models only.  
Quick Boil  
Express-Select® Controls  
Boils water faster.  
Easily go from warm to boil.  
Continuous Grates  
Fits-More™ Cooktop  
Continuous grates make it easy to  
move heavy pots and pans between  
burners without lifting.  
The Fits-More™ cooktop features five  
burners so you can cook more at once.  
frigidaire.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Built-In Cooktops  
FGGC3645K S/W/B 36" Gas  
Required Clearances  
Product Dimensions  
B-Depth  
A-Width  
C-Height  
G (min.)  
H (min.)  
I (min.)  
J (min.)  
36"  
21-3/4"  
5"  
2"  
7"  
7"  
2-1/4"  
Utility Connection Locations  
Product Cutout Dimensions  
E-Depth (min.ꢀ-max.)  
19-1/4" - 19-3/4"  
K-Cabinet Opening Width  
(min.)  
D-Width (min.ꢀ-max.)  
F-Height (min.)*  
PowerSupply  
Gas Supply  
33-7/8" - 34-1/4"  
8"  
36"  
Right Rear  
Right Rear  
Built-In Cooktop Specifications  
Product Shipping Weight (approx.) – 60 Lbs.  
Voltage Rating – 120Vꢀ/ꢀ60 Hzꢀ/ꢀ15 Amps  
For use on adequately wired 120V, dedicated circuit having 2-wire  
service with a separate ground wire. Appliance must be grounded  
for safe operation.  
Amps @ 120 Volts = 1.0 Amps  
Always consult local and national electric and gas codes.  
Cooktop cutout height includes clearance needed beneath cooktop  
to allow for gas supply connection. Recommended location for  
grounded 120V outlet is on rear wall in an 8"-wide by 10"-high area,  
positioned 22" above floor surface and 4" from right side of cooktop  
centerline. Access to underside of cooktop and junction box must  
be provided for inspection and service.  
Cooktop ships with 3/4" factory regulator.  
LP Gas conversion kit supplied.  
Overhead cabinetry should not exceed a 13" maximum depth.  
Allow 7" minimum required clearance from left edge of cooktop to  
adjacent combustible surface and 7" minimum from right edge of  
cooktop to adjacent combustible surface.  
Installation of drawer beneath cooktop requires 6-1/2" minimum  
clearance beneath countertop surface, and assured clearance for gas  
and electrical connections.  
To reduce risk of fire when using overhead cabinetry, install range  
hood that projects horizontally a recommended minimum of 5"  
beyond bottom of cabinets.  
Gas Built-In Cooktop model FGGC3645K is approved to be used  
over any Frigidaire® Electric Single Wall Oven. (Refer to Gas Cooktop  
Installation Over 30"ꢀ/ꢀ27" Electric Single Wall Oven Specifications  
page on web.)  
Gas Built-In Cooktop model FGGC3645K is approved to be used in  
combination with Frigidaire® 36" Downdraft Vent E36DD75ESS or  
PL36DD50EC. (Refer to model-specific Downdraft Vent product page  
on web for detailed countertop preparation specifications.)  
Absolute minimum horizontal distance between overhead cabinets  
installed to either side of appliance must be no less than 36".  
Allow 30" minimum clearance between top of cooktop platform and  
bottom of unprotected wood or metal overhead cabinet.  
Allow 2" minimum distance between rear edge of cutout and adjacent  
combustible surface (or backsplash).  
Note: For planning purposes only. Refer to Product Installation Guide  
on the web at frigidaire.com for detailed instructions.  
Optional Accessories  
Granite Countertop Installation Kit – (PN # 903103-9010).  
Accessories information available  
on the web at frigidaire.com  
USA 10200 David Taylor Drive Charlotte, NC 28262 1-800-FRIGIDAIRE frigidaire.com  
Specifications  
subject to change.  
CANADA 5855 Terry Fox Way Mississauga, ON L5V 3E4 1-800-265-8352 frigidaire.ca  
FGGC3645K 04/11 © 2011 Electrolux Home Products, Inc.  
Printed in the U.S.A.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Gas Cooktop Installation  
Over 27"ꢀElectric Single Wall Oven (GLEB27Z7H)  
27" Electric Single Wall Oven (GLEB27Z7H)  
Under-Counter Installation Specifications  
Gas Cooktop Installation Over  
27" Electric Single Wall Oven (GLEB27Z7H) Specifications  
Single phase 3- or 4-wire cable, 120ꢀ/ꢀ240 or 120ꢀ/ꢀ208 Volt, 60 Hertz  
AC only electrical supply with ground required on separate circuit  
fused on both sides of line.  
For detailed electrical requirements, refer to model-specific product  
page and installation guide on web.  
Always consult local and national electric codes.  
Minimum 27-1/4" clearance for oven door depth when open.  
Minimum 23-1/2" deep cutout dimension is critical for proper  
installation, to ensure that oven’s faceplate will fit flush against  
cabinet front.  
Frigidaire® Single Wall Oven model GLEB27Z7H is approved to be used  
beneath any approved Frigidaire® Gas Cooktop.  
For detailed Gas Cooktop installation, refer to model-specific product  
page and installation guide on web.  
Side filler panel height may need to be modified to accommodate the  
depth of approved gas cooktop models.  
Minimum height opening of 6-1/2" (from top of counter) required in  
right side filler panel to route gas and electric hookups.  
Allow 4-1/2" maximum height from oven base to floor, if cooktop is  
installed directly over wall oven.  
Minimum 4-1/2" distance required from door hinge side of oven’s  
cutout opening to any adjoining cabinetry or wall, to allow sufficient  
clearance for oven rack removal.  
Note: For planning purposes only. Refer to Product Installation Guide  
on the web at frigidaire.com for detailed instructions.  
Side filler panels necessary to isolate oven from adjoining cabinets.  
Oven base of solid plywood or similar material required, capable of  
supporting 150 Lbs. Install over two runners and flush with toe plate.  
Base must be level and cabinet front must be square.  
Recommended that bottom of cabinet remain partially opened to  
permit free air circulation, avoiding possible water condensation  
which may appear inside control panel while operating oven.  
Allow 5" maximum height from oven base to floor, if NO cooktop is  
installed directly over wall oven.  
USA 10200 David Taylor Drive Charlotte, NC 28262 1-800-FRIGIDAIRE frigidaire.com  
Specifications  
subject to change.  
CANADA 5855 Terry Fox Way Mississauga, ON L5V 3E4 1-800-265-8352 frigidaire.ca  
GC_EW_SS INST FR 03/11 © 2011 Electrolux Home Products, Inc.  
Printed in the U.S.A.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Gas Cooktop Installation  
Over 30"/27"ꢀElectric Single Wall Oven  
30"/ꢀ27" Electric Single Wall Oven  
Under-Counter Installation Specifications  
Gas Cooktop Installation Over  
30"/ꢀ27" Electric Single Wall Oven Specifications  
Single phase 3- or 4-wire cable, 120ꢀ/ꢀ240 or 120ꢀ/ꢀ208 Volt, 60 Hertz  
All Frigidaire® Electric Single Wall Ovens are approved to be used  
beneath any approved Frigidaire® Gas Cooktop. (This installation page  
excludes approved wall oven model GLEB27Z7H. For model-specific  
installation details, refer to Gas Cooktop Installation Over 27" Electric  
Single Wall Oven GLEB27Z7H Specifications pages on web.)  
For detailed Gas Cooktop installation, refer to model-specific product  
page and installation guide on web.  
AC only electrical supply with ground required on separate circuit  
fused on both sides of line.  
For detailed electrical requirements, refer to model-specific product  
page and installation guide on web.  
Always consult local and national electric codes.  
Minimum 21" clearance for oven door depth when open.  
Side filler panel height may need to be modified to accommodate the  
depth of approved gas cooktop models.  
Minimum height opening of 6-1/2" (from top of counter) required in  
right side filler panel, to route gas and electric hookups.  
Allow 4-1/2" maximum height from oven base to floor, if cooktop is  
installed directly over wall oven.  
Minimum 23-1/2" deep cutout dimension is critical for proper  
installation, to ensure that oven’s faceplate will fit flush against  
cabinet front.  
Side filler panels necessary to isolate oven from adjoining cabinets.  
Full oven base of solid plywood or similar material required, capable  
of supporting 200 Lbs. (30" models) or 150 Lbs. (27" models).  
Install over two runners and flush with toe plate.  
Base must be level and cabinet front must be square.  
Allow 5" maximum height from oven base to floor, if NO cooktop is  
installed directly over wall oven.  
Note: For planning purposes only. Refer to Product Installation Guide  
on the web at frigidaire.com for detailed instructions.  
USA 10200 David Taylor Drive Charlotte, NC 28262 1-800-FRIGIDAIRE frigidaire.com  
Specifications  
subject to change.  
CANADA 5855 Terry Fox Way Mississauga, ON L5V 3E4 1-800-265-8352 frigidaire.ca  
GC_EW INST FR 03/11 © 2011 Electrolux Home Products, Inc.  
Printed in the U.S.A.  
Download from Www.Somanuals.com. All Manuals Search And Download.  

FieldServer Computer Drive FS 8704 09 SNMP User Manual
Fisher Price Bicycle T6209 User Manual
Franke Consumer Products Cooktop FNE 905 XS ECS User Manual
FUNAI Flat Panel Television CSTL2006 User Manual
Garmin GPS Receiver Vista C User Manual
Gateway Network Router DPC3925 User Manual
Generac Power Systems Portable Generator 91355 User Manual
GE VCR VG4252 User Manual
Global Machinery Company Air Compressor EAC30 User Manual
Go Video Flat Panel Television TW1730 User Manual