Frigidaire Air Conditioner P N 66121617 User Manual

USE & CARE MANUAL  
NOTE: This USE & CARE MANUAL  
Contents  
provides specific operating instructions  
for your model. Use the room air  
conditioner only as instructed in this USE  
& CARE MANUAL instructions are not  
meant to cover every possible condition  
and situation that may occur. Common  
sense and caution must be practiced when  
installing, operating, and maintaining any  
appliance.  
2
Warranty  
3
Product Registration  
Packaging  
3
3
Normal Sounds  
4
Important Safety Instructions  
Operation of Current Device  
Air Conditioner Features  
Care and Cleaning  
4
5-10  
11  
11  
12  
Energy Saving Ideas  
Avoid Service Checklist  
READ AND SAVE THESE INSTRUCTIONS  
MEDIAN and HEAVY DUTY  
ELECTRONIC CONTROL  
AIR CONDITIONERS  
P/N 66121617  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Record Your Model and Serial Numbers  
Record in the space provided below the model and serial numbers. On all models, the serial  
plate is located on the outside of the cabinet.  
Product Registration  
Model No.  
Serial No.  
Register Your Product  
The self-addressed PRODUCT REGISTRATION CARD should be filled in completely, signed  
and returned to the Frigidaire Company.  
Packaging  
Remove all packaging from inside the unit ,also any inserts placed into  
the side louvers.  
Packing Inserts  
Packing + straps  
Normal Sounds  
High Pitched Chatter  
Todays high efficiency compressors  
may have a high pitched chatter  
during the cooling cycle.  
Vibration  
Unit may vibrate and make noise  
because of poor wall or window  
construction or incorrect installation.  
Sound of Rushing Air  
At the front of the unit, you may  
hear the sound of rushing air  
being moved by the fan.  
Pinging or Swishing  
Droplets of water hitting condenser  
during normal operation may cause  
pinging or swishingsounds.  
Gurgle/Hiss  
Gurgling or hissingnoise may be heard  
due to refrigerant passing through  
evaporator during normal operation.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Read all instructions before using this air conditioner.  
Important Safety  
Instructions  
For Your Safety  
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any  
other appliance. Read product labels for flammability and other warnings.  
The power supply cord with  
this air conditioner contains a current  
detection device designed to reduce the risk  
of fire.  
Please refer to the section Operation of  
Current Devicefor details.  
In the event that the power supply cord is  
damaged, it cannot be repaired it must be  
replaced with a cord from the Product  
Manufacturer.  
Prevent Accidents  
To reduce the risk of fire, electrical shock, or injury to persons when using your air conditioner,  
follow basic precautions, including the following:  
Be sure the electrical service is adequate for the model you have chosen. This information  
can be found on the serial plate, which is located on the side of the cabinet and behind the  
grille.  
If the air conditioner is to be installed in a window, you will probably want to clean both  
sides of the glass first. If the window is a triple-track type with a screen panel included,  
remove the screen completely before installation.  
Be sure the air conditioner has been securely and correctly installed according to the  
separate installation instructions provided with this manual. Save this manual and the  
installation instructions for possible future use in removing or reinstalling this unit.  
When handling the air conditioner, be careful to avoid cuts from sharp metal fins on front  
and rear coils.  
Avoid fire hazard or electric  
shock. Do not use an extension cord or an  
adaptor plug. Do not remove any prong from  
the power cord.  
Grounding type wall  
receptacle  
Electrical Information  
The complete electrical rating of your new room air conditioner is stated on the serial plate.  
Refer to the rating when checking the electrical requirements.  
Do not, under any  
circumstances, cut,  
remove, or bypass the  
grounding prong.  
Be sure the air conditioner is properly grounded. To minimize shock and fire hazards,  
proper grounding is important. The power cord is equipped with a three-prong grounding  
plug for protection against shock hazards.  
Your air conditioner must be used in a properly grounded wall receptacle. If the wall  
receptacle you intend to use is not adequately grounded or protected by a time delay fuse  
or circuit breaker, have a qualified electrician install the proper receptacle.  
Do not run air conditioner with outside protective cover in place. This could result in  
mechanical damage within the air conditioner.  
Do not use an extension cord or an adapter plug.  
Power supply cord  
with 3-prong grounding  
plug and current  
detection device  
READ THIS SECTION BEFORE ATTEMPTING TO OPERATE AIR CONDITIONER.  
The power supply cord contains a current device that senses damage to the power cord. To  
test your power supply cord do the following:  
Operation of Current  
1. Plug in the Air Conditioner.  
Device  
2. The power supply cord will have TWO buttons on the plug head. Press the TEST button.  
You will notice a click as the RESET button pops out.  
3. Press the RESET button. Again you will notice a click as the button engages.  
4. The power supply cord is now supplying electricity to the unit. (On some products this is  
Plug in &  
press RESET  
also indicated by a light on the plug head).  
NOTES:  
Do not use this device to turn the unit on or off.  
Always make sure the RESET button is pushed in for correct operation.  
The power supply cord must be replaced if it fails to reset when either the TEST button is  
pushed, or it cannot be reset. A new one can be obtained from the product manufacturer.  
If power supply cord is damaged, it CANNOT be repaired. It MUST be replaced by one  
obtained from the product manufacturer.  
NOTE: Some plugs have  
buttons on the top.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
ELECTRONIC CONTROL OPERATING INSTRUCTIONS  
Before you begin, thoroughly familiarize yourself with the control panel and remote as shown  
below and all its functions, then follow the symbol for the functions you desire. The unit can  
be controlled by the touch pad alone or with the remote.  
Air Conditioner Features  
LIGHT  
ON/OFF  
Temp/Timer  
ADJUSTS  
TEMP &  
TIME  
DISPLAYS  
TEMPERATURE/TIME  
FAN SPEED  
AUTO TEMP  
FEATURE  
ADJUSTS  
TEMP &  
TIME  
SETS  
FAN  
SLEEP MODE  
SPEED  
T emp/Timer  
CHECK FILTER  
RESET BUTTON  
Cool  
Energy  
Saver  
Fan  
Only  
SETS  
MODE  
ACTIVATE  
TIMER  
Sleep  
Au t o  
T emp  
Timer  
CLEAN AIR  
FEATURE  
(some models)  
Heater  
AUTO TEMP  
SETS FAN SPEED  
REMOTE CONTROL  
FOR HEAT MODELS  
Fig. "A"  
SETS MODE  
TURNS UNIT  
ON OR OFF  
LIGHT  
ON/OFF  
ACTIVATES  
TIMER  
Temp/Timer  
TOUCH PAD  
ADJUSTS  
TEMP &  
TIME  
SETS  
FAN  
SPEED  
T emp/Timer  
Cool  
Energy  
Saver  
Fan  
LIGHT  
Only  
SETS  
MODE  
ON/OFF  
ACTIVATE  
TIMER  
Sleep  
Au t o  
T emp  
Timer  
Temp/Timer  
Remote
Sensing  
ADJUSTS  
TEMP &  
TIME  
AUTO TEMP  
SETS  
REMOTE CONTROL  
w/DISPLAY &  
FAN  
SPEED  
T emp/Timer  
REMOTE SENSING  
BUTTON  
SETS  
Cool  
Energy  
Saver  
Fan  
Only  
ACTIVATE  
TIMER  
MODE  
Fig. "B"  
Sleep  
Au t o  
T emp  
Timer  
AUTO TEMP  
STANDARD REMOTE  
Battery Size: AAA  
Warning:  
do not mix old and new batteries. Do not mix alkaline, standard (carbon-zinc),or rechargeable(nickel-cadmium) batteries.  
NOTE: The following instructions represent the Touch Pad, the same instructions can be used for the Remote Control.  
TO TURN UNIT ON: YOU WILL SEE:  
DO THIS:  
PRESS ON/OFF  
BUTTON  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Air Conditioner Features  
(continued)  
TO CHANGE TEMPERATURE  
SETTING:  
YOU WILL SEE:  
DO THIS:  
PRESS TO  
RAISE  
PRESS TO  
LOWER  
Note: Tap or hold either up ( ) or down ( ) button until the desired temperature is seen on the display. This temperature will be automati-  
cally maintained anywhere between 60oF (16oC) and 90oF (32oC) for cooling mode. The temperature will be automatically maintained anywh-  
ere between 55oF (13oC) and 80oF (27oC) for heating mode. If you want the display to read the actual room temperature. See "To Operate  
on Fan Only" section on Page 7.  
TO ADJUST FAN SPEEDS:  
YOU WILL SEE :  
DO THIS:  
PRESS  
TO SELECT:  
FASTER  
SLOWER  
Press the Fan Faster button will increase the fan speed from Low (LO), to Medium (ME), to High (HI). The digital display will indicate  
your chosen speed. Press the Fan Slower button will decrease the fan speed from High (HI), to Medium (ME), to Low (LO).The digital display will  
indicate your chosen speed.After 5 seconds the display will revert back to the set temperature.  
YOU WILL SEE:  
TO USE AUTO TEMP FEATURE:  
LIGHT On  
DO THIS:  
PRESS  
AUTO TEMP  
Note: Fan speed starts at High Speed and adjusts to a slower speed as the room temperature dictates, For example if the room doesn't  
get too warm, it will stay at the slowest speed. If the room temperature rises quickly,such as a door being opened, it will automatically go  
to the highest speed. The fan speeds will re-adjust back to the slowest speed as the room returns to the original set temperature.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Air Conditioner Features  
(continued)  
TO OPERATE ON FAN ONLY:  
YOU WILL SEE:  
LIGHT On  
DO THIS:  
PRESS  
MODE BUTTON  
CHOOSE  
FAN ONLY  
Note: Use this function only when cooling is not desired, such as for room air circulation or to exhaust stale air. (Remember to open the  
vent during this function, but keep it closed during cooling for maximum cooling efficiency.) You can choose any fan speed you prefer. (Exc-  
ept "Auto Temp").  
During this function, the display will show the actual room temperature, not the set temperature as in the cooling mode.  
Fan Only cannot be selected when the unit is in the 'Remote Sensing' Mode. (On those units with that feature).  
TO USE THE  
YOU WILL SEE:  
ENERGY SAVER FEATURE:  
LIGHT On  
DO THIS:  
PRESS  
MODE BUTTON  
CHOOSE  
ENERGY SAVER  
Note:  
In this mode, the fan will continue to run for another 3 minutes after the compressor shuts off. The fan then cycles on for 2 minutes  
at 10 minute intervals until the room temperature is above the set temperature, at which time the the cooling system turns back on.  
LIGHT On  
TIMER: DELAY START/STOP FEATURE:  
YOU WILL SEE HOW MUCH TIME IS CHOSEN:  
FIRST  
DO THIS:  
PRESS  
TIMER BUTTON  
THEN  
DO THIS:  
PRESS  
TEMP/TIMER  
SET BUTTON  
Note 1:  
Note 2:  
For Delay Stop, the unit must be in the On position.  
For Delay Start, the unit must be in the Off position.  
First, PRESS TIME BUTTON  
Then to adjust timer setting, tap or hold the UP arrow (  
) or the DOWN arrow (  
) to change delay timer at. 5 hour increments, up to 10  
hours, then by 1 hour increments up to 24 hours. The control will count down the time remaining until start (8, 7.5, 7, etc.). The Delay Start  
mode automatically selects cooling with maximum Fan Speed. The temperature maintained will be the same as previously set. To change the  
set temperature, press "COOL" then Up or Down arrows until the desired temperature is indicated on the display. After 5 seconds, the con-  
trol will automatically change the display back to the hours remaining until the unit will start/stop. PRESSING the unit On/Off button at any  
time will cancel the Delay Start/Stop function. The Delay Start/Stop Feature will work until the unit either starts or stops. Once that happens  
he above steps have to be repeated again.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Air Conditioner Features  
(continued)  
CHECK FILTER FEATURE:  
LIGHT On  
YOU WILL SEE:  
Note:  
This feature is a reminder to clean the Air Filter (See Care and Cleaning) for more efficient operation and cooling. The LED (light) will  
illuminate after 250 hours of operation. To reset after cleaning the filter, press the "Check Filter" button and the light will go off.  
CLEAN AIR FEATURE(on some models):  
YOU WILL SEE:  
LIGHT On  
DO THIS:  
PRESS  
CLEAN AIR  
BUTTON  
Note: When this feature is "ON", the electronic air purifier is energized to remove pollen and impurities from the air. To cancel this feature,  
press the Clean Air button (the LIGHT will turn off).  
Note: This feature can be activated on the unit touchpad ONLY.  
LIGHT On  
YOU WILL SEE:  
SLEEP FEATURE:  
DO THIS:  
PRESS  
SLEEP BUTTON  
Note: In this "MODE" the set temperature will increase by 2 degrees F 30 minutes after the mode is selected. The temperature will then  
increase by another 2 degrees F after an additional 30 minutes. This new temperature will be maintained for 7 hours before it returns to the or-  
iginally selected temperature. This ends the "Sleep" MODE and the unit will continue to operate as originally programmed. The "Sleep"  
MODE program can be cancelled at any time during operation by again pressing the "Sleep" button.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
Air Conditioner Features  
(continued)  
REMOTE SENSING FEATURE  
(on some models) :  
LIGHT pulsing On Off intermittently.  
T emp/Timer  
T emp/Timer  
T emp/Timer  
T emp/Timer  
DO THIS:  
Cool  
Slee  
Ener g y  
Sa v er  
Fa  
n
Onl  
y
Cool  
Slee  
Ener g y  
Sa v er  
Fa  
n
Onl  
y
p
Au t o  
T emp  
Timer  
PRESS REMOTE  
SENSING  
BUTTON ON  
p
Au t o  
T emp  
Timer  
Staorpt  
R
emote  
Sensing  
Staorpt  
R
emote  
Sensing  
NOTE: Remote display  
NOTE:Unit display shows"set"temperature  
is actual temperature at  
remote control only  
Note: This feature can be activated from the remote control ONLY,the unit must be in a cooling mode.  
To activate the remote sensing feature,point the remote control towards the unit and press the remote sensing button.Next,use the  
buttons to set the desired temperature at the remote.(Note that the set temperature will only be displayed on the unit itself).The LIGHT on  
the unit control will pulse to indicate it received the signal.The LIGHT on the remote control will pulse each time it sends a signal.It will con-  
tinue to send this signal until the feature is deactivated by pressing the remote sensing button.If the unit does not receive the remote sensing  
signal during any 3 minute interval,the unit will beep to indicate the remote sensing mode has ended.The display on the remote control indicates  
the temperature at the remote ONLY. The unit display indicates the set temperature.  
Remote Sensing:The Remote Sensing function is terminated using the remote control Start/Stop button or the Remote Sensing  
Stop button, and also the main Start/Stop button on the unit.  
YOU WILL SEE:  
HEATING FEATURE (on some modes)  
DO THIS:  
PRESS  
MODE BUTTON  
SELECT HEAT  
Note: This feature can be used with any combination of FAN Speeds, Timer, or Sleep Modes.When in the "Heat" Mode,the fan will run  
continuously while heat is needed. The temperature will automatically be maintained anywhere between 55 F(13) and 80 F(27)  
When the room set temperature is satisfied,the fan will cycle off and on to circulate and sample the room air.  
YOU WILL SEE:  
TO TURN UNIT OFF:  
DO THIS:  
PRESS  
ON/OFF BUTTON  
Note: When unit is shut off in the Heat Mode, the fan will continue to run for a few seconds to dissipate  
residual heat within the unit.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
Air Conditioner Features  
(continued)  
FAULT CODES  
If the display reads"HS", a sensor has failed.  
Contact your Authorized Frigidaire Service  
Center.  
If the display reads"ES", a sensor has failed.  
Contact your Authorized Frigidaire Service  
Center.  
If the display reads"AS", a sensor has failed.  
Contact your Authorized Frigidaire Service  
Center.  
ADDITIONAL THINGS YOU SHOULD KNOW  
Now that you have mastered the operating procedure,here are more features in your control that you should become familiar with:  
The “Cool” circuit has an automatic 3 minute time delayed start if the unit is turned off and on  
quickly.This prevents overheating of the compressor and possible circuit breaker tripping.The  
fan will continue to run during this times.  
The control will maintain the set temperature within 2 degrees Fahrenheit,between 60F and 90F degrees.  
The control is capable of displaying temperature in degrees Fahrenheit or degrees Celsius.To convert from one to the other and back,  
Press and hold the"TEMP/TIMER"Up (  
) and Down (  
) buttons together for 3 seconds.  
Fresh Air Vent Control(On some models)  
The Fresh Air Vent allows the air conditioner to:  
1. Recirculate inside air - Vent Closed (see Fig. 1)  
2. Draw fresh air into the room - Vent Open (see Fig. 2)  
3. Exchange air from the room and draws fresh air into the room - Vent and Exhaust  
Open (see Fig. 3)  
Fig. 3 (VENT)  
Fig. 1 (OFF)  
Fig. 2 (FRESH AIR)  
The louvers will allow you to direct the air flow Up or Down and Left or Right throughout  
the room as needed.Rotate the Auger Wheel Up or Down until the desired direction is  
obtained.  
(4-WAY)  
AUGER WHEEL  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Clean your air conditioner occasionally to keep it looking new. Be sure to unplug the  
unit before cleaning to prevent shock or fire hazards.  
Care and Cleaning  
Air Filter Cleaning  
The air filter should be checked at least once a month to see if cleaning is necessary.  
Trapped particles in the filter can build up and cause an accumulation of frost on the  
cooling coils.  
Push the vent handle to the Vent Closed position (where applicable).  
Open the front panel.  
Grasp the filter by the center and pull up and out.  
Wash the filter using liquid dishwashing detergent and warm water. Rinse filter  
thoroughly. Gently shake excess water from the filter. Be sure filter is thoroughly dry  
before replacing.  
Or, instead of washing you may vacuum the filter clean.  
Cabinet Cleaning  
Be sure to unplug the air conditioner to prevent shock or fire hazard. The cabinet and  
front may be dusted with an oil-free cloth or washed with a cloth dampened in a solution  
of warm water and mild liquid dishwashing detergent. Rinse thoroughly and wipe dry.  
Never use harsh cleaners, wax or polish on the cabinet front.  
Be sure to wring excess water from the cloth before wiping around the controls. Excess  
water in or around the controls may cause damage to the air conditioner.  
Plug in air conditioner.  
Winter Storage  
If you plan to store the air conditioner during the winter, remove it carefully from the  
window according to the installation instructions. Cover it with plastic or return it to the  
original carton.  
Do not block air flow inside with blinds, curtains or furniture; or outside with shrubs,  
enclosures, or other buildings.  
The capacity of the room air conditioner must fit the room size for efficient and satisfactory  
Energy Saving Ideas  
operation.  
Install the room air conditioner on the shady side of your home. A window that faces north  
is best because it is shaded most of the day.  
Close the fireplace damper, floor and wall registers so cool air does not escape up the  
chimney and into the duct work.  
Keep blinds and drapes in other windows closed during the sunniest part of the day.  
Clean the air filter as recommended in the section “Care and Cleaning.”  
Proper insulation and weather stripping in your home will help keep warm air out and cool  
air in.  
External house shading with trees, plants or awnings will help reduce the air conditioner’s  
work load.  
Operate heat producing appliances such as ranges, washers, dryers and dishwashers  
during the coolest part of the day.  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Before calling for service, review this list. It may save you time and expense. This list  
includes common occurrences that are not the result of defective workman-ship or  
materials in this appliance.  
Avoid Service Checklist  
OCCURRENCE  
SOLUTION  
Air conditioner will not operate.  
Wall plug disconnected. Push plug firmly into wall outlet.  
Plug Current Device Tripped. Press the RESET button.  
House fuse blown or circuit breaker tripped. Replace fuse with time delay type or reset circuit breaker.  
Control is OFF. Turn Control ON and set to desired setting.  
Air from unit does not feel cold  
enough.  
Room temperature below 60°F (16°C). Cooling may not occur until room temperature rises above 60°F (16°C).  
Temperature sensing element touching cold coil, located behind air filter. Straighten away from coil.  
Reset to a Lower temperature.  
Compressor shut-off by changing modes. Wait approximately 3 minutes and listen for compressor to restart  
when set in the COOL mode.  
Air conditioner cooling, but room is  
too warm - ice forming on cooling  
coil behind decorative front.  
Outdoor temperature below 60°F (18°C). To defrost the coil, set FAN ONLY Mode.  
Air filter may be dirty. Clean filter. Refer to Care and Cleaning section. To defrost, set to FAN ONLY Mode.  
Temperature is set too Low for night-time cooling. To defrost the coil, set to FAN ONLY Mode. Then, set Tem-  
perature to a Higher setting.  
Air conditioner cooling, but room is  
too warm - NO ice forming on  
cooling coil behind decorative front.  
Dirty air filter - air restricted. Clean air filter. Refer to Care and Cleaning section.  
Temperature is set too High. Set temperature to a Lower setting.  
Air directional louvers positioned improperly. Position louvers for better air distribution.  
Front of unit is blocked by drapes, blinds, furniture, etc. - restricts air distribution. Clear blockage in front of unit.  
Doors, windows, registers, etc. open - cold air escapes. Close doors, windows, registers, etc.  
Unit recently turned on in hot room. Allow additional time to remove “stored heat” from walls, ceiling, floor and  
furniture.  
Air conditioner turns on and off  
rapidly.  
Dirty air filter - air restricted. Clean air filter.  
Outside temperature extremely hot. Set FAN speed to a faster setting to bring air past cooling coils more  
frequently.  
Noise when unit is cooling.  
Air movement sound. This is normal. If too loud, set to a slower FAN setting.  
Window vibration - poor installation. Refer to installation instructions or check with installer.  
Water dripping INSIDE when unit is  
cooling.  
Improper installation. Tilt air conditioner slightly to the outside to allow water drainage. Refer to installation  
instructions - check with installer.  
Water dripping OUTSIDE when unit  
is cooling.  
Unit removing large quantity of moisture from humid room. This is normal during excessively humid days.  
Remote Sensing Deactivating  
Prematurely (Some Models).  
Remote control not located within range. Place remote control within 20 feet & 180°, radius of the front of the  
unit.  
Remote control signal obstructed. Remove obstruction.  
Set temperature too low. Increase set temperature.  
Room Too Cold.  
Remote Sensing activated (on some models) and remote control located in Hot Spot - Relocate remote  
control or deactivate remote sensing.  
If These Solutions Fail, Call 1-800-444-4944 For Frigidaire Service.  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Eiki Projector LC SX2U User Manual
Fisher Paykel Dishwasher DD603 User Manual
Fitness Quest Home Gym Gym1000 User Manual
Ford Motorized Toy Car P5064 User Manual
Frigidaire Microwave Oven FFMV164L S User Manual
GE Clothes Dryer 175D1807P241 User Manual
Gemini Car Stereo System CDX 1210 User Manual
Gemini MP3 Player iKEYplus User Manual
GE Range 164D3333P069 User Manual
GE Washer Dryer WSM2780 Gas User Manual