1 Quick Installation Guide  
1.1 Introduction  
The freeView IP 800 redirects local keyboard, mouse and video data to a remote administration  
console. All data is transmitted via IP. The freeView IP 800 can also be used in a multi  
administrator and multi server environment. Also, the freeView IP 800 is a KVM switch which can  
be used with a local console.  
1.2 Hardware Installation  
In order to connect to the freeView IP 800, perform the following steps:  
1. Connect the power supply to the freeView IP 800.  
2. Connect the monitor to the freeView IP 800.  
3. Connect the keyboard to the freeView IP 800.  
4. Connect the mouse to the freeView IP 800.  
5. Plug the HDDB-15 pin connector of a 3-in-one KVM cable into Port 1 on the rear of the  
freeView IP 800 unit. Then connect the HDDB-15 pin male type for PC video, the purple  
Mini-Din 6 pin female type for the keyboard and the green Mini-Din 6 pin female type for a  
mouse into the respective ports on the computer.  
6. Repeat step 5 for each PC being connected to the freeView IP 800.  
7. Connect the Ethernet cable and/or analog modem, depending on how you want to access  
freeView IP 800.  
1.3 Video Modes  
The freeView IP 800 supports many common video modes. Please refer to Appendix C for a list  
of all supported video modes.  
1.4 Initial IP Configuration  
By default, the freeView IP 800 uses the network parameters shown in Table 1-1.  
Parameter  
Value  
IP auto configuration DHCP  
IP-Address  
None  
Net-mask  
255.255.255.0  
None  
Default-Gateway  
Table 1-1: Default Network Settings  
If these network parameters do not match the network configuration, the device's network  
settings can be configured using the program KVMSetup.exe located on the installation CD after  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
freeView IP 800 User’s Manual  
the unit has been connected to the network and powered on.  
To change the network settings of the device:  
1. Open Windows Explorer and browse to the CD drive.  
2. Double-click the file KVMSetup.exe.  
3. A screen similar to Figure 1-1 will be displayed.  
Figure 1-1: KVM Setup Program  
4. Select the unit’s MAC address from the drop-down list under “Device MAC address”.  
5. Enter the desired IP address for the device under “Network Configuration”.  
6. Enter the user name and password under “Authentication”. The default user name is  
“super” and the default password is “pass”.  
7. Click “Setup Device”.  
1.5 Web Interface  
The freeView IP 800 may be accessed using a standard JAVA enabled web browser. You may  
use the HTTP protocol or a secure encrypted connection via HTTPS. Enter the configured IP  
address of the IP-KVM switch into your web browser.  
The default user name and password to log into the device are shown below.  
User name  
Password  
super  
pass  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
freeView IP 800 User’s Manual  
It is recommended that the default password be changed immediately to prevent unauthorized  
access to the device.  
1.6 Remote Console  
The Remote Console is the redirected screen, keyboard and mouse of the remote host system to  
which the freeView IP 800 is connected. The web browser which is used to access the unit has to  
have Java Runtime Environment version 1.1 or higher installed. However, it is strongly  
recommended that the Sun JVM 1.4 is installed. The Remote Console will behave exactly the  
same way as if you were sitting directly in front of the screen of your remote system. That means  
that both the keyboard and mouse can be used in the usual way. Open the console by selecting  
the preview picture on the main site of the HTML front end. Figure 1-2 shows the top of the  
Remote Console.  
Figure 1-2: Remote Console  
Once connected, the following can be performed to improve the user experience:  
Auto Adjust button  
If the video displayed is distorted, click this button and the device will automatically adjust its  
display to improve the quality.  
Sync Mouse button  
Choose this option in order to synchronize the local with the remote mouse cursor. This is  
especially necessary when using accelerated mouse settings on the host system. In general  
there is no need to change mouse settings on the host.  
Video Settings in Options Menu  
This opens a new window with elements to control the PS/2 IP-KVM switch Video Settings. You  
can change some values, for instance the brightness and contrast of the picture displayed, which  
may improve the video quality. It is also possible to revert to the default settings for all video  
modes or only the current one.  
Note: After starting up, if the local mouse pointer is not synchronized with the remote mouse  
pointer, press the Auto Adjust Button once.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
freeView IP 800 User’s Manual  
2 Introduction  
Thank you for purchasing the freeView IP 800. The freeView IP 800 saves money, time, space,  
equipment and power. The freeView IP 800 defines a new class of remote KVM access devices;  
it combines digital remote KVM access via IP networks with comprehensive and integrated  
system management.  
The device provides convenient, remote KVM access and control via LAN or Internet. It captures,  
digitizes, and compresses the video signal and transmits it and keyboard and mouse signals to  
and from a remote computer. The freeView IP 800 provides a non-intrusive solution for remote  
access and control. Remote access and control software runs on the embedded processor only  
and not on the mission-critical servers, so that there is no impact on server or network  
performance.  
Furthermore, the freeView IP 800 offers additional remote power management when used with  
an optional IP Power device.  
The device supports consoles consisting of a PS/2 keyboard and mouse and HDDB 15 video  
output and will automatically detect the current video mode of the console. The freeView IP 800  
will accept video streams up to 110 MHz. This results in a screen resolution of 1280x1024 pixels  
with a frame rate of 60 Hz.  
2.1 When The Server Is Operational  
The freeView IP 800 gives you full control over the remote server. The Management Console  
allows you to access the remote server’s graphics, keyboard and mouse and the ability to send  
special commands to the server. You can also perform periodic maintenance on the server.  
Using the Remote Console, you can do the following:  
A. Reboot the system.  
B. Monitor the boot process.  
C. Boot to a different operating system on dual-boot machines.  
D. Boot up in Windows Safe Mode.  
E. Boot the system from a separate partition to load diagnostic environment.  
F. Run special diagnostic programs.  
2.2 When The Server Is Non-Operational  
Using the freeView IP 800, the system administrator can discover problems with the server;  
though fixing hardware problems is not possible through a remote management device.  
Nevertheless, the device gives the administrator valuable information about the type of hardware  
failure. Serious hardware failures can be categorized into five different categories, with the  
percentage chance of failure listed below:  
A. Hard disk failure 50%  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
freeView IP 800 User’s Manual  
B. Power cable detached, power supply failure 28%  
C. CPU, Controller, main board failure 10%  
D. CPU fan failure 8%  
E. RAM failure 4%  
Using the freeView IP 800, administrators can determine which kind of hardware failure has  
occurred (See table 2-1).  
Type of Failure  
Detected By  
Hard disk failure  
Console screen, CMOS set-up information  
Power cable detached, power supply failure Server remains in power off state after power on  
command has been given.  
CPU Controller, main board failure.  
CPU fan failure  
Power supply is on, but there is no video output.  
Server specific management software  
Boot-sequence on boot console  
RAM failure  
Table 2-1: Host System Failures and Detection Methods  
2.3 Features  
Remote mass storage control 8 port KVM over IP switch is has a 19” rack mount size design  
Supports DOS, Win3.X, Win95/98/98SE/2000/ME/XP, WinNT, Netware, Unix, Linux  
Supports iMAC, Power MAC and Sun Microsystems with USB port (Requires the use of a  
USB-PS/2 adapter)  
Hot Plug - Add PCs or Remove Connected PCs for Maintenance without Powering down the  
KVM switch or PCs.  
High Video Quality – Resolution Up To 1920X1440 (local side), 1280 X1024 (remote side)  
No Software Required - easy PC selection via On Screen Display Menu (OSD), Push Buttons,  
Hot Keys  
At local console side - Support eight characters password protection and search PC server  
name  
At Remove console side – Use SSL protocol for any encrypted network traffic between itself  
and a connected client.  
Keyboard status restored when switching PCs  
LED Display for easy status monitoring  
Buzzer sound for switching port confirmation  
Built-in daisy chain port  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
freeView IP 800 User’s Manual  
Daisy chain bank is automatically detected, no need for a DIP switch  
Manage servers around the world  
KVM (keyboard, video, mouse) access over IP and analog telephone line (external modem  
required)  
BIOS level access  
No impact on server or network performance  
Automatically senses video resolution for best possible screen capture  
High-performance mouse tracking and synchronization  
SSL encryption  
2.4 Package Contents  
freeView IP 800  
1 PC  
1 PC  
1 PC  
1 PC  
1 SET  
1 PC  
1 PC  
1 PC  
Quick Install Guide  
Installation software and User Manual on CD-ROM  
AC to DC Power Adapter  
Rack mount Kit  
Null modem cable  
USB A to B 6 feet cable  
3-in-1 3 feet KVM cable  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
freeView IP 800 User’s Manual  
2.5 Technical Specifications  
Model No.  
freeView IP 800 switch  
PC Port  
8
Console Port  
1
PC Port Connector  
(All Female Types)  
Console Port Connector  
(All Female Types)  
VGA HDDB 15-pin(shared with PS/2 keyboard and Mouse)  
Local Console: PS/2 Keyboard Mini Din 6 pin  
PS/2 Mouse Mini Din 6 pin  
VGA HDDB 15pin  
Remote Console: RJ-45 8P8C  
Daisy Chain Port Connector  
(All Female Types)  
PS/2 Keyboard mini Din 6 pin  
PS/2 Mouse Mini Din 6 pin  
VGA HDDB 15pin  
Serial Port (DB9 pin Male)  
LAN port (RJ-45 8P8C)  
1
10BASE-T Ethernet uses Category 3/4/5/5E/6 UTP  
100BASE-T Ethernet uses Category 5/5E/6 UTP  
Reset button  
1
PC selection  
On Screen Display Menu, Hot Key, Push Button  
PC Port LED  
8
Bank 7 segment LED  
On Screen Display Control  
Scan Intervals  
1
Yes  
5~99 Sec.  
Keyboard Emulation  
Mouse Emulation  
VGA Resolution  
PS/2  
PS/2  
Local Console: 1920X1440  
Remote Console: 1280 X1024  
8 levels  
Daisy Chain MAX Level  
MAX PC Connection  
Housing  
120  
Metal  
Power Adapter  
Operation Temperature  
Storage Temperature  
Humidity  
DC 5V, 2.5A  
0 ~ 50°C  
-20 ~ 60°C  
0~80%, Non-Condensing  
19” Rack Mount / 1RU  
2.0kg  
Size  
Weight (kg)  
Dimensions (cm)  
41(L) X 16.4(W) X 4.6(H)  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
freeView IP 800 User’s Manual  
2.6 System Requirements  
Model No.  
freeView IP 800 switch  
Local console side  
One VGA Monitor  
One Keyboard  
One Mouse  
Network side  
10/100Mbps Ethernet  
or Modem  
Remote Console side One computer  
Computer side  
8 PCs with 8 3-in-one cables (One HDDB 15-pin male to one HDDB  
15-pin and two Mini Din 6-pin PS/2 cables)  
2.7 Cable Diagrams  
PS/2 Cable:  
Mini Din 6 pin Male to Male  
VGA Cable:  
HDB15 pin Male to Male  
AT to PS/2 keyboard adapter: (Optional)  
Din 5 pin Male to Mini Din 6 pin Female  
PS/2 to DB9 adapter (Optional)  
Mini Din 6 pin Female to DB 9 pin Female  
CAT5/5E/6 Straight Through UTP/STP Cable:  
8P8C  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
freeView IP 800 User’s Manual  
2.8 Product Details  
8 port Rack Mount PS/2 IP-KVM switch:  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
freeView IP 800 User’s Manual  
3 Hardware Installation  
3.1 Operation Overview  
Figure 3-1 shows an example of how to connect the freeView IP 800 KVM switch to its host, to  
peripheral devices, to the power source and to the local area network.  
Administrator  
IP Network  
freeView IP 800  
Administrator  
8 Servers  
Figure 3-1: freeView IP 800 Usage Scenario  
The unit redirects local keyboard, mouse, and video data to a remote administration console. All  
data is transmitted via IP.  
The unit can also be used in a multi administrator and multi server environment.  
3.2 Connecting The freeView IP 800 To The Host System  
Before installation, make sure all peripherals and computers have been turned off. This example  
of installation is based on the freeView IP 800. In order to connect the unit to the host system,  
please perform the following steps:  
Step 1  
Attach the power supply to the KVM unit and plug the other end into an electrical receptacle.  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
freeView IP 800 User’s Manual  
Step 2  
Find a convenient place to put the unit. Its 19” rack mount form factor makes it ideal for mounting  
on a 19” rack. When mounting to a rack, attach the included brackets to the sides of the unit.  
Take note of the length of your cables so that your computers, KVM Switch, keyboard, mouse  
and monitor are distanced properly.  
Step 3  
Connect the monitor to the KVM Switch. Using the attached cable, or the one included with your  
monitor, connect it to the HDDB15-pin female port on the back of the KVM unit labeled with the  
monitor symbol at the CONSOLE connector.  
Step 4  
Connect the keyboard to the KVM Switch. If you have an AT type keyboard, you will need an AT  
to PS/2 adapter.  
Step 5  
Connect the mouse to the KVM Switch.  
Step 6  
Each PC port connector is HDDB15-pin type. Locate your input cable. It will have an  
HDDB15-pin male connector at one end. Plug it into any labeled computer port on the rear of  
KVM switch unit. The other end of input cable will have three connectors: a HDDB15-pin male  
type for PC video, a Mini Din 6 pin female type for keyboard and a Mini Din 6 pin female type for  
mouse, plug these three connectors into the respective ports of the computer. Repeat the same  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
freeView IP 800 User’s Manual  
procedure for each computer.  
Step 7  
Double-check all of the connections. You can check the color of keyboard and mouse connectors  
to make sure the keyboard and mouse cables go to the correct ports.  
Step 8  
Repeat steps 6 and 7 for the remainder of the computers.  
Step 9  
Connect the Ethernet and/or modem, depending how you want to access the unit.  
Internet  
Modem  
The rear side of the unit provides an RJ-45 connector for Ethernet. The connector is used for  
either a 100 Mbps 100BASE-TX connection or for a 10 Mbps 10BASE-T connection. The adapter  
can sense the connection speed and will adjust to the appropriate operation mode automatically.  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
freeView IP 800 User’s Manual  
Using a 10 Mbps Connection  
For 10BASE-T Ethernet networks, the Ethernet adapter uses Category 3, 4, 5 or 6 UTP cable. To  
establish a 10 Mbps connection, the cable must be connected to a 10BASE-T hub.  
Make sure that the cable is wired appropriately for a standard 10BASE-T adapter.  
Align the RJ-45 plug with the notch on the adapter’s connector and insert it into the adapter’s  
connector.  
Using a 100 Mbps Connection  
For 100BASE-TX Fast Ethernet networks, the freeView IP 800 supports Category 5 or higher  
UTP cabling. To establish a 100 Mbps connection, the cable must be connected to a  
100BASE-TX hub or switch.  
Make sure that the cable is wired appropriately for a standard 100BASE-TX adapter.  
Align the RJ-45 plug with the notch on the adapter’s connector and insert it into the adapter’s  
connector.  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
freeView IP 800 User’s Manual  
4 Configuration  
4.1 Initial Configuration  
The freeView IP 800 is shipped with the network configuration listed in Table 4-1.  
Parameter  
IP auto configuration  
IP-Address  
Value  
DHCP  
None  
Net-mask  
255.255.255.0  
None  
Default-Gateway  
Table 4-1: Initial Network Configuration  
Note: If the DHCP connection fails on boot up, the freeView IP 800 will not have an IP address.  
If this initial configuration does not meet your requirements, the following describes the initial IP  
configuration that is necessary to access the PS/2 IP-KVM switch for the first time.  
4.2 Initial Configuration Via DHCP Server  
By default, the freeView IP 800will attempt to contact a DHCP server in the subnet to which it is  
physically connected. If a DHCP server is found, it may provide a valid IP address, gateway  
address and subnet mask. Before you connect the device to your local subnet, be sure to  
complete the corresponding configuration of your DHCP server. It is recommended to configure a  
fixed IP assignment to the MAC address of the unit. You can find the MAC address label on the  
bottom of the unit.  
If this initial configuration does not meet your local requirements, use the setup tool to adjust the  
values to your needs. The setup tool can be found on the CD ROM delivered with this package.  
You can follow the procedure described below.  
4.3 freeView IP 800 Setup Program  
Connect the freeView IP 800 to a computer via local network or USB. Start the setup tool  
KVMSetup.exe located on the Installation Disk on the computer. The program screen is shown in  
Figure 4-1.  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
freeView IP 800 User’s Manual  
Figure 4-1: freeView IP 800 Setup Tool  
On the upper left corner, the MAC address(es) of all freeView IP 800 switches are displayed. To  
rescan for devices, click “Refresh Devices”.  
1. Select the MAC address of the unit to be configured from the dropdown list.  
2. Click “Query Device” to populate the current configuration of the device.  
3. Enter the network configuration settings in the Network Configuration screen.  
4. Enter the username and password of the device in the Authentication screen. The default  
username is “super” and the default password is “pass”.  
5. If desired, enter a new password for the super user. Note: Write down the new password and  
keep it in a safe, secure location for later reference.  
6. Click “Setup Device” to save the new settings.  
7. Click “OK” to close the window.  
4.4 Initial Configuration Via Serial Console  
Connect a null modem cable from a serial port on a computer to the RS-232 port on the console  
side of the freeView IP 800. Open up a terminal access program (e.g. HyperTerminal) to access  
the device. The unit uses the terminal parameters shown in Table 4-2.  
Parameter  
Bits/second  
Data bits  
Value  
115200  
8
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
freeView IP 800 User’s Manual  
Parity  
No  
Stop bits  
1
Flow Control  
None  
Table 4-2: Serial Line Settings  
1. Power off the unit.  
2. Power on the unit and immediately press the <Esc> key.  
3. After the boot up sequence is completed, a “=>” prompt will appear.  
4. Type “config” and press the <Enter> key and wait for the configuration questions to appear.  
5. For each question, type in the desired settings, or press <Enter> to accept the default value  
shown in square parenthesis [ ].  
6. The parameters that can be set are as follows:  
IP auto configuration (none/dhcp/bootp) [dhcp]:  
With this option, the user can specify whether the freeView IP 800 gets its network settings from  
a DHCP or BOOTP server. For DHCP, enter “dhcp”, and for BOOTP enter “bootp”. If neither  
option is selected, the IP auto configuration is disabled and the network settings will need to be  
configured manually.  
IP [192.168.1.22]:  
The IP address of the unit. This option is only applied if IP auto configuration is set to none.  
Net mask [255.255.255.0]:  
The subnet mask of the unit. This option is only applied if IP auto configuration is set to none.  
Gateway (0.0.0.0 for none) [0.0.0.0]:  
The IP address of the default gateway of the device. If a default gateway is not available, enter  
0.0.0.0. This option is only applied if IP auto configuration is set to none.  
4.5 Keyboard, Mouse And Video Configuration  
The freeView IP 800 can be connected to the host machine’s peripheral ports via PS/2 or USB.  
The correct operation of the remote mouse depends on several settings which will be discussed  
in the following subsections.  
4.5.1  
freeView IP 800 Keyboard Settings  
The freeView IP 800’s settings for the host keyboard type have to be correct in order for the  
remote keyboard to work properly. See Section 6.4.2 for details.  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
freeView IP 800 User’s Manual  
4.5.2  
Remote Mouse Settings  
A common problem with KVM devices is the synchronization between the local and remote  
mouse cursors. The freeView IP 800 addresses this problem with an intelligent synchronization  
algorithm. There are two mouse modes available on the freeView IP 800:  
1. Auto mouse speed  
The automatic mouse mode tries to detect the speed and acceleration settings of the host  
system automatically. See the section below for a more detailed explanation.  
2. Fixed mouse speed  
This mode translates the mouse movements from the Remote Console in a way that one pixel  
move will lead to a fixed number of pixel moves on the remote system. The number of pixels can  
be adjusted using the scaling feature. It should be noted that this will only work when mouse  
acceleration is turned off on the remote system.  
4.5.3  
Auto Mouse Speed And Mouse Synchronization  
The automatic mouse mode performs the speed detection during mouse synchronization. If the  
local mouse loses synchronization with the remote mouse, there are two methods for  
re-synchronizing local and remote mouse:  
1. Fast Sync  
Fast synchronization is used to correct a temporary, but fixed skew. Choose this option using the  
Remote Console options menu or press the mouse synchronization hotkey sequence if it has  
been defined.  
2. Intelligent Sync  
If fast synchronization does not work or the mouse settings have been changed on the host  
system, use intelligent resynchronization. This method takes more time than the fast  
synchronization and can be accessed in the Remote Console option menu. Intelligent  
synchronization requires the picture be adjusted correctly. Use the auto adjustment function or  
the manual correction in the Video Settings panel to configure the picture. The Sync Mouse  
button at the top of the Remote Console behaves differently, depending on the current state of  
mouse synchronization. Pressing this button will perform a fast sync, except when the KVM port  
or the video mode have been changed, in which case an intelligent sync will be performed.  
Note: When using the console for the first time, press the Auto Adjust Button if the local mouse  
pointer is not synchronized with the remote mouse pointer.  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
freeView IP 800 User’s Manual  
4.5.4  
Host System Mouse Settings  
The host's operating system knows various settings from the mouse driver.  
Note: The following limitations do not apply if the Mouse Type is set to USB and “MS Windows  
2000 and newer”.  
While the freeView IP 800 works with accelerated mice and is able to synchronize the local with  
the remote mouse pointer, there are limitations which may prevent this synchronization from  
working properly:  
Special Mouse Driver  
There are mouse drivers which influence the synchronization process and lead to  
desynchronized mouse pointers. If this occurs, disable the vendor-specific mouse driver on the  
host system.  
Windows XP Mouse Settings  
Windows XP has a setting called “improve mouse acceleration” which has to be deactivated.  
Active Desktop  
If the Active Desktop feature of Microsoft Windows is enabled, do not use a plain background,  
use a wallpaper instead. Alternatively, Active Desktop can be disabled altogether.  
Move the mouse pointer to the upper left corner of the applet screen and move it back and forth  
slightly to resynchronize the mouse. If resynchronizing fails, disable mouse acceleration and  
repeat the procedure.  
4.5.5  
Single and Double Mouse Modes  
The information above applies to the Double Mouse Mode, where both the remote and local  
mouse pointers are visible and need to be synchronized. The freeView IP 800 also supports a  
Single Mouse Mode, where only the remote mouse pointer is visible. Enable this mode in the  
open Remote Console and click in the window area to activate it. The local mouse pointer will be  
hidden and the remote mouse pointer can be controlled directly. To leave this mode, it is  
necessary to define a mouse hotkey in the Remote Console Settings Panel. Press this key to  
free the captured local mouse pointer.  
4.5.6  
Recommended Mouse Settings  
The following are suggestions for mouse modes for various operating systems:  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
freeView IP 800 User’s Manual  
MS Windows 2000/2003 (Professional and Server), XP  
It is recommended to use the USB mouse option. Choose USB without Mouse Sync. For a PS/2  
mouse choose Auto Mouse Speed. For XP disable the “enhance pointer precision” option in the  
Control Panel.  
SUN Solaris  
Adjust the mouse settings either via xset m 1 or use the CDE Control Panel to set the mouse to  
1:1, no acceleration. As an alternative, use Single Mouse Mode.  
MAC OS X  
It is recommended that the Single Mouse Mode be used.  
4.5.7  
Video Modes  
The freeView IP 800 supports most common video modes. When running X11 on the host  
system, do not use any custom mode lines with special video modes, otherwise, the device may  
not be able to detect the video mode. It is recommended that a standard VESA video mode is  
used instead.  
24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
freeView IP 800 User’s Manual  
5 Usage  
5.1 Prerequisites  
The freeView IP 800 features an embedded operating system and applications offering a variety  
of standardized interfaces. This chapter will describe both these interfaces, and how to use them  
in detail. The interfaces are accessed using the TCP/IP protocol, thus they can be accessed  
though the Ethernet interface.  
5.2 HTTP/HTTPS  
Full access is provided by the embedded web server. The freeView IP 800 can be managed  
using a standard web browser. The web interface can be accessed using the insecure HTTP  
protocol, or the encrypted HTTPS protocol. Whenever possible, use HTTPS for increased  
security.  
5.3 Telnet  
A standard Telnet client can be used to access an arbitrary device connected to the freeView IP  
800’s serial port via a terminal mode.  
The primary interface of the freeView IP 800 is the HTTP interface. This is covered extensively in  
this chapter. Other interfaces are addressed in subtopics.  
In order to use the Remote Console window of the managed host system, the browser has to  
support Java Runtime Environment (JRE) version 1.1 or higher. If the browser does not have  
Java support (such as on a PDA), the web interface and be accessed and configure, but the  
remote console will be unavailable.  
Important: It is recommended that the latest version of Sun’s JVM is installed.  
For an insecure (HTTP) connection to the device, the following browsers are recommended:  
Microsoft Internet Explorer version 6.0 or higher on Windows 98, Windows ME, Windows  
2000 and Windows XP  
Netscape Navigator 7.0 or Mozilla 1.6 on Windows 98, Windows ME, Windows 2000,  
Windows XP, Linux and other UNIX-like Operating Systems  
In order to access the remote host system using a securely encrypted connection, a browser that  
supports the HTTPS protocol is required. Strong security is only assured by using a key length of  
128-bit. Some older browsers do not support 128-bit encryption.  
Using the Internet Explorer, the current key length supported can be found under “Help”, “About  
Internet Explorer”. The dialog box contains a link that leads to information on how to upgrade the  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
freeView IP 800 User’s Manual  
browser to a state of the art encryption scheme. Figure 5-1 shows the dialog box presented by  
the Internet Explorer 6.0.  
Figure 5-1: Encryption Key Length in Internet Explorer  
Newer web browsers support strong encryption by default.  
5.4 Using the freeView IP 800 as a KVM Switch  
The power on state of the freeView IP 800:  
When you power on KVM switch, it will ask you for the password, the default password value is  
eight zeros – “00000000”. Key in eight zeros and enter the same value at retype field.  
Note: Until you are familiar with the operation of the OSD, don’t change the password – i.e. keep  
default eight zeros (00000000) value. Otherwise, if you have changed the password and forget  
the password, you will need to send it back to your distributor to reset the password.  
The Push Buttons  
freeView IP 800 IP-KVM Switch  
Buttons  
~
:
1
8
Press the button that corresponds to the server you wish to activate.  
PC Port LED Indication:  
There are two LED indicators for each port, a Green LED and an Orange LED located above  
each PC port selection button.  
When you select a PC port and the PC is shut down or the PC port is disconnected from the PC,  
the selected port LED will flash Green. When you select a PC port and the PC is powered on and  
connected, the selected port LED will be solid Green. For each port that has a PC that is  
connected and powered on but is not currently the selected port, the LED will be solid Orange.  
26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
freeView IP 800 User’s Manual  
7-Segment BANK LED Indication  
When you would like to view the next bank KVM switch, please press the “BANK“ push button  
cyclically until you reach the destination bank. The bank LED will be changed from bank 1 to the  
maximum daisy chain level and then press cycle back to bank 1.  
Bank 1  
Bank 2  
Bank 3  
MAX. BANK  
Bank  
8
Reset Button ((“  
Bank ” button) and (PC 8 “  
” button)):  
Press both the “Bank” button and any one of the “PC1~PC8” buttons of the master bank  
simultaneously to reset the KVM switch. This reset action will not only return the KVM switch  
back to its initial state, verify the password and also rescan all of the slave banks which  
connected to the master KVM Switch.  
If you add a new unit as a slave bank, use the reset button of master unit to automatically assign  
a new ID to it. You can view this new slave bank by going through the OSD menu. The PC ports  
of the unit are not reset by using the reset command.  
Keyboard Hot Key Commands:  
You can control the KVM switch by switching ports using simple key sequences. To send  
commands to the KVM switch, the <Scroll Lock> (<ScrLk>) key must be pressed twice  
within 2 seconds. You will hear a beep for confirmation and the keyboard is change to hot key  
mode. If you do not press a key in hot key mode within 2 seconds (i.e. pressing a key after  
pressing the <Scroll Lock> key twice), the keyboard will go back to the Operation System (OS)  
control state.  
Below are the different hot key commands for the local KVM:  
within 2 seconds  
Scroll  
Lock  
Scroll  
Lock  
+
+
+
+
= Previous Channel  
= Next Channel  
Scroll  
Lock  
Scroll  
Lock  
Note: Hold down the direction key to quickly cycle through the ports.  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
freeView IP 800 User’s Manual  
Scroll  
Lock  
Scroll  
Lock  
Page  
Up  
+
+
+
+
= Previous Bank  
= Next Bank  
Scroll  
Lock  
Scroll  
Lock  
Page  
Down  
To select PC port:  
Port No.  
Scroll  
+
Scroll  
Bank  
01~08 (8 port)  
01~16 (16 port)  
01~32 (32 port)  
+
+
+
= Selected bank and PC  
Lock  
Lock  
No 1~8  
Scroll  
Lock  
+
Scroll  
Lock  
= Beeper on local KVM Switch  
B
Note: The default Beeper function is ON and beeper control is only available for Scan Mode  
Scroll  
Scroll  
Lock  
S
+
+
= Auto Scan  
Lock  
Note: To exit Auto Scan Mode, press any key or the <Spacebar>.  
28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
freeView IP 800 User’s Manual  
Scroll  
Lock  
Scroll  
Lock  
+
+
+
+
+
+
= OSD setting back to factory default value.  
R
(Note: This does not affect the password)  
Scroll  
Lock  
Scroll  
Lock  
F
= Search the same PC name  
Scroll  
Lock  
Scroll  
Lock  
SPACE BAR  
= On Screen Display Menu  
5.5 Daisy Chain Connection Diagram  
1. Connect one end of the included 3-in-one KVM cable to the Daisy Chain port on the back of  
the master unit.  
2. Connect the other end of the KVM cable to the Console port on the slave unit.  
3. Repeat steps 1 and 2 to connect up to 8 units together in one stack.  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
freeView IP 800 User’s Manual  
Table 5-1: Daisy Chain Connection  
5.6 Hot Plug  
The freeView IP 800 supports a “Hot Plug“ function for easy addition or removal of PCs. The user  
can arrange or maintain PCs as follows:  
1. A PC can be disconnected and reconnected to the same or different port of the KVM unit  
without having to power it off as long as it is not the Daisy-chain port or pass through port.  
2. You may unplug the mouse or the keyboard from the console port and plug it back in at any  
time.  
Note: Some operating system, e.g. Unix, are unable to support the “Hot Plug” function. If you  
apply “Hot Plug” to this kind of operating system, it will cause unpredictable behavior or shut  
down the PC. Before attempting to use “Hot Plug”, please make sure your OS and mouse driver  
support the “Hot Plug” function.  
30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
freeView IP 800 User’s Manual  
5.7 On Screen Display Operation  
The On Screen Display (OSD) menu can be opened by pressing the hot key combination  
(<Scroll Lock> + <Scroll Lock> + <Spacebar>). The following window will be displayed on your  
monitor.  
The first section displays the active bank number.  
The second section displays the list of systems. A sun symbol indicates that a computer is  
connected to that port and powered on.  
You will find the system number list from 01 to 08 (freeView IP 800). You can customize the  
PC names, up to a maximum of 10 characters. The factory default names are from “SYSTEM  
01”, “SYSTEM 02”, etc.  
Use the up arrow key “y“ or down arrow key “z“ to select the port. After you have selected  
the port, you can press the <Enter> key to switch to the PC connected to that port. Press the  
“INS” key to edit the PC name. After you are finished, press the <Enter> key to save the  
information.  
Use the <PgUp> key or <PgDn> key for selecting the previous or next Bank number.  
Use the <Tab> key to select items like Bank, OSD, SCAN, CHANGE PASSWORD,  
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
freeView IP 800 User’s Manual  
CONSOLE ON/OFF, etc.  
“OSD: 10 SEC” is the amount of time the system name will be displayed on the monitor after  
the computer is selected. This value can be set from 05 sec to 99 sec. The factory default  
value is 10 sec.  
“SCAN TIME” is the scan interval from one PC port to next PC during Auto Scan mode. The  
default scan time is 10 sec and the maximum scan time is 99 sec.  
“CHANGE PASSWORD” is used to change the password for accessing the systems. The  
default password is 8 digits “00000000“.  
An enter password window appears when you select this item. The maximum password is 8  
digits. After you key in the password and press the <Enter> key, another window appears to  
confirm the password you entered.  
You need to retype the password again to verify.  
“CONSOLE ON/OFF“ determines whether the password needs to be entered to access the  
console. “CONSOLE ON” means that any user can access the console. “CONSOLE OFF”  
means that the password needs to be entered to access the console. Once the password is  
32  
Download from Www.Somanuals.com. All Manuals Search And Download.  
freeView IP 800 User’s Manual  
entered once to access the console, this value will be set to “CONSOLE ON”. Remember to  
set it to “CONSOLE OFF” again if you want to lock it after closing the console. Also, if the  
current CONSOLE is ON state and you reset KVM switch, the CONSOLE will set the ON  
state back to OFF state.  
When you finish setting the system name and exit the OSD mode, you will find the active  
system name displayed at the top-left corner of monitor. You can press the <Esc> key to clear  
the message right away if you don’t need it.  
If you want the OSD to return back to factory default value, you can enter the key  
combination <Scroll Lock>, <Scroll Lock>, <R>. The seven segment Bank LEDs on the front  
panel will flash during the refresh process.  
When the OSD value is back to default settings, the seven segment Bank LEDs on the front  
panel will stop flashing.  
5.8 Logging In And Logging Out  
5.8.1 Logging In  
Launch the web browser and enter the address of the freeView IP 800 in the Address Bar. The  
address used can be an IP address or a host and domain name, in the case where the DNS  
server has a symbolic name. For example, type the following in the address line of the web  
browser when establishing an unsecured connection:  
When using a secure connection, type in:  
The login page will be displayed (Figure 5-2).  
33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
freeView IP 800 User’s Manual  
Figure 5-2: Login Screen  
The device has a built-in super user that has full access to the device. The default username  
and password for the super user are show in Table 5-12  
Login name  
Password  
super (factory default)  
pass (factory default)  
Table 5-2: Default User Settings  
Note: The super user cannot access the device via the serial interface.  
Note: Change the super user password as soon as possible. Failure to do so will pose a  
severe security risk and will allow unauthorized users to access the device.  
Navigation  
After logging into the freeView IP 800, the main page shown in Figure 5-3 will be displayed. This  
page consists of three parts: the buttons on the upper side allow the user to navigate within the  
web interface (see Table 5-3 for details). The lower left frame contains a navigation bar which  
allows the user to switch between the different sections of the unit. The lower right frame displays  
details of the menu item selected on the left frame.  
34  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
freeView IP 800 User’s Manual  
Figure 5-3: Main Page  
Return to the main page of the freeView IP  
800.  
Show the remote console.  
Log out of the web interface.  
Table 5-3: Web Interface Icons  
5.8.2  
Logging Out  
To log out of the web interface, click the Logout button on the main window. The user will also be  
logged out automatically after 30 minutes of inactivity.  
5.9 The Remote Console  
General description  
The Remote Console is the redirected screen, keyboard and mouse of the remote host system  
35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
freeView IP 800 User’s Manual  
connected to the freeView IP 800.  
Figure 5-4: Remote Console  
The Remote Console window is a Java Applet that establishes its own connection to the  
freeView IP 800. The protocol used by the Remote Console is RFB (Remote Frame Buffer  
Protocol). Currently, RFB uses port number 443 to establish a connection. For proper operation,  
ensure that the local network environment allows traffic on port 443.  
Note: If the freeView IP 800 is connected to the Internet through a proxy server without NAT, the  
Remote Console will not be available from the WAN interface because web proxies are not able  
to relay the RFB packets.  
In case of problems, consult the network administrator for proper network configuration.  
5.10 Main Window  
Starting the Remote Console will open another additional window which displays the screen  
content of the host system. The Remote Console will behave the same as if it was being used  
locally, including the keyboard and mouse. However, the reaction time for the keyboard and  
mouse will have a slight delay. The severity of the delay depends on the bandwidth available to  
access the unit. Also, special keyboard combinations (e.g. <Ctrl>-<Alt>-<Del> in Windows) will  
affect the local system and not the remote system. See the next section for more details.  
Note: If a keyboard whose language is different from the host system’s default language is used  
(e.g. a US English local keyboard is used to control a remote host running a German operating  
system), the local language will be used instead of the remote language. In the previous example,  
US characters will be sent to the host instead of German characters. To emulate the remote host  
language, select the appropriate language using the Local Keyboard option in the dropdown  
menu. See the next section for more details.  
The Remote Console window will automatically adjust to fit the size of the remote screen.  
36  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
freeView IP 800 User’s Manual  
However, the Remote Console window can be resized manually in the local window system the  
same way as other applications.  
Note: The Remote Console window must be selected in the local operating system in order for  
mouse and keyboard input to be sent to the remote host.  
5.10.1 Remote Console Control Bar  
The top bar of the Remote Console window shown in Figure 5-5 contains the control bar. The  
control bar displays the state of the remote device and also allows the user to change the  
Remote Console settings.  
Figure 5-5: Remote Console Control Bar  
Ctrl+Alt+Delete  
This button sends the key combination “Control-Alt-Delete” to the remote system (see Section 6  
for instructions on defining new key combination buttons).  
Auto Adjust button  
If the video display becomes distorted, click this button and wait a few seconds while the device  
tries to automatically readjust the video settings.  
Sync mouse button  
This button activates the mouse synchronization process. Choose this option to synchronize the  
local with the remote mouse cursor. This is especially necessary when using accelerated mouse  
settings on the host system. In general, there is no need to change mouse settings on the host.  
This button is only available when using double mouse mode.  
Single/Double Mouse Mode  
This button switches between Single Mouse Mode (only the remote mouse pointer is visible) and  
Double Mouse Mode (both remote and local mouse pointers are visible and need to be  
synchronized). Single mouse mode is only available if using SUN JVM 1.3 or higher.  
37  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
freeView IP 800 User’s Manual  
Options  
This button opens the Options menu  
Figure 5-6: Remote Console Options Menu  
A short description of the options follows.  
Monitor Only  
Toggles Monitor Only mode on and off. If Monitor Only is enabled, remote console interaction is  
disabled and only monitoring is possible.  
Exclusive Access  
Toggles Exclusive Access mode if the user has the appropriate access level. When Exclusive  
Access is enabled, other users cannot open the Remote Console until the current user disables  
Exclusive Access or logs off the system.  
A change in access mode is also visible in the status line (Figure 5-7).  
Figure 5-7: Remote Console Exclusive Mode  
Scaling  
Allows the user to scale down the display of the Remote Console. The user can still use both the  
38  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
freeView IP 800 User’s Manual  
mouse and the keyboard; however the scaling algorithm may distort some items on the display.  
Figure 5-8: Remote Console Options Menu – Scaling  
Mouse Handling  
The submenu for mouse handling offers two options for synchronizing the local and the remote  
mouse pointer.  
Fast Sync: The fast synchronization is used to correct a temporary, but fixed skew.  
Intelligent Sync: Use this option if fast sync does not work or if the mouse settings have been  
changed on the host system.  
Note: Intelligent Sync takes more time than Fast Sync. Use the auto adjustment function or  
manual correction in the Video Settings panel to setup the picture.  
Local Cursor  
Offers a list of different cursor shapes to choose from for the local mouse pointer. The selected  
shape will be saved for the current user and activated the next time this user opens the Remote  
Console. The number of available shapes depends on the Java Virtual Machine; a version of 1.2  
or higher offers the full list.  
39  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
freeView IP 800 User’s Manual  
Figure 5-9: Remote Console Options Menu – Local Cursor  
Video Settings  
This option opens a panel for changing the video settings for the freeView IP 800. The unit  
features two different dialogs, which influence the video settings:  
Video Settings Through The Web Interface  
This option enables the local video port. This option determines whether or not the video output  
from the host is transmitted to the local monitor.  
The Noise Filter option defines how the freeView IP 800 reacts to small changes in the video  
input signal. A large filter setting uses less network traffic and leads to a faster video display, but  
small changes in the display may not be recognized and updated on the remote immediately. A  
small filter setting displays all changes on the remote host instantly but will produce more  
network traffic (depending on the quality of the video input signal). The default setting should be  
suitable for most situations.  
40  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
freeView IP 800 User’s Manual  
Video Settings Through The Remote Console  
Figure 5-10: Video Settings Panel  
Brightness: Controls the brightness of the picture.  
Contrast: Controls the contrast of the picture.  
Clock: Defines the horizontal frequency for a video line and depends on the video mode.  
Different video card types may require different values. The default settings in conjunction with  
the auto adjustment procedure should be adequate for common configurations. If the picture  
quality is still poor after auto adjustment, change this setting together with the sampling phase to  
achieve a better quality.  
Phase: Defines the phase for video sampling, used with the sampling clock setting to control the  
display quality.  
Horizontal Position: Adjusts the horizontal position of the screen.  
Vertical Position: Adjusts the vertical position of the screen.  
Reset this Mode: Reset current mode specific settings to the factory-made defaults.  
Reset all Modes: Reset all modes to the factory-made defaults.  
Save Changes: Save changes permanently.  
Undo Changes: Restore last saved settings.  
41  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
freeView IP 800 User’s Manual  
Soft Keyboard  
Figure 5-11: Soft Keyboard  
Show  
Opens the Soft-Keyboard screen (Figure 5-11). The Soft-Keyboard is necessary in the case  
where the host system uses a completely different language and country mapping from the  
administration machine.  
Mapping  
Used for choosing the appropriate language and country mapping of the Soft-Keyboard.  
Figure 5-12: Soft Keyboard Mapping  
Local Keyboard  
Used to change the language mapping of the Remote Console Applet. Under normal  
circumstances, the applet automatically determines the appropriate value. However, the applet  
may not determine the correct value depending on the particular JVM and the browser settings. A  
42  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
freeView IP 800 User’s Manual  
typical example is a German localized system that uses an US-English keyboard mapping. In  
this case the Local Keyboard will need to be changed to the correct setting manually.  
Hotkeys  
Opens a list of defined hotkeys. By choose an entry, the selected command will be sent to the  
host system.  
A confirmation dialog can be added that will be displayed before sending the selected command  
to the remote host. Select “OK” to perform the command on the remote host.  
Figure 5-13: Remote Console Confirmation Dialog  
Encoding  
Figure 5-14: Encoding  
Allows the user to adjust both the compression rate and the colour depth individually. Depending  
on the selected compression rate, the data stream between the freeView IP 800 and the Remote  
Console will be compressed in order to save bandwidth. Increasing the compression rate  
requires more resources from the freeView IP 800, thus should not be used when multiple users  
43  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
freeView IP 800 User’s Manual  
are accessing the remote console simultaneously.  
The default color depth is 16 Bit (65536 colors). The other color depths are intended for slower  
network connections since they require less bandwidth. Therefore compression level 0 (no  
compression) uses only 16 Bit color depth. At lower bandwidths, only 4 Bit (16 colors) and 2 Bit  
(4 gray scales) are recommended for typical desktop interfaces. Photo-quality pictures have best  
results with 4 Bit (16 gray scales). 1 Bit color depth (black/white) should only be used for  
extremely slow network connections.  
5.10.2 Remote Console Status Line  
Status line  
The status line shows both the console and the connection state. The size of the remote screen  
is displayed as well. Figure 5-15 shows a Remote Console with a resolution of 1024x768 pixels.  
The value in brackets describes the connection to the Remote Console. “Norm” indicates a  
standard connection without encryption; “SSL” indicates a secure connection.  
Figure 5-15: Status Line  
Furthermore, both the incoming (“In”) and the outgoing (“Out”) network traffic are visible in kb/s. If  
compressed encoding is enabled, a value in brackets displays the compressed transfer rate.  
Figure 5-16: Bandwidth Usage  
For more information about Monitor Only and Exclusive Access settings, see the next section.  
44  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
freeView IP 800 User’s Manual  
6 Menu Options  
6.1 Remote Control  
The Remote Control menu allows the user to access the host system via web interface or Telnet.  
6.1.1  
KVM Console  
Figure 6-1: KVM Console  
There are several methods to open the Remote Console window: click the Console icon on the  
top bar, click the menu entry KVM Console on the left menu bar, or click on the console picture  
on the right. To refresh the static picture of the remote host screen, click on the “Refresh” button.  
6.1.2  
Telnet Console  
Figure 6-2: Telnet Console  
The freeView IP 800 features a Telnet server that enables the user to connect to the host via a  
standard Telnet client. If the Telnet program uses a VT100, VT102 or VT220 terminal emulation  
45  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
freeView IP 800 User’s Manual  
(or a similar emulation), it is possible to perform a console redirection as long as the host  
machine is using a text based operating system (e.g. Unix).  
Connecting to the freeView IP 800 requires a telnet client on the local machine. To access the  
device, run the telnet program and specify the IP address of the unit. For example, if the unit’s IP  
address is 192.168.1.22, type in “telnet 192.168.1.22” in Unix or Windows. Once connected, the  
user will be prompted for username and password. The credentials for authentication are  
identical to those of the web interface.  
Once the user has successfully logged into the device, a command line will be presented and the  
user can enter management commands.  
The Telnet interface supports two operation modes: the command line mode and the terminal  
mode. The command line mode is used to control or display device parameters. In terminal mode  
the connection is made from the local machine to the device connected to the serial port on the  
unit (if the serial settings are set correctly). All user input on the local machine are redirected to  
the device connected to the serial port and the response is displayed on the Telnet interface.  
The following list shows the commands available in mode command and their usage.  
Command Description  
help  
Displays the list of available commands  
cls  
Clears the screen  
quit  
Exits the current session and disconnects from the client  
Displays the release information  
version  
terminal  
Starts the terminal pass-through mode for the serial port. The key sequence “esc  
exit” switches back to the command mode. The command has an optional  
parameter (1 or 2) to select the desired serial port for pass-through access (only  
number 1 is supported at this time).  
Table 6-1: Telnet Commands  
6.2 User Management  
The User Management menu allows the user to manage user accounts on the freeView IP 800.  
46  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
freeView IP 800 User’s Manual  
6.2.1  
Change Password  
Figure 6-3: Set Password  
To change the current user’s password, enter the new password in the upper entry field. Retype  
the password in the filed below. Click “Apply” to submit the changes.  
47  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
freeView IP 800 User’s Manual  
6.2.2  
Users And Groups  
Figure 6-4: Set User  
The freeView IP 800 comes with 2 pre-configured user accounts that have fixed permissions.  
The account “super” has all possible rights to configure the device and use all of the functions  
available. The account “user” only has permission to open and use the Remote Console.  
By default, both accounts have the password pass. Remember to change these passwords  
immediately after the device has been installed and accessed for the first time.  
While the “user” account never sees the following options, the “super” account can change the  
name and password for both accounts.  
Existing users: Select an existing user for modification. Once a user has been selected, click  
the lookup button to see the user information.  
New user name: The new user name for the selected account.  
Password: The password for the login name. It must be at least four characters long.  
Confirm password: Confirm of the password above.  
6.3 KVM Settings  
The KVM Settings menu allows the user to change settings related to the remote console.  
48  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
freeView IP 800 User’s Manual  
6.3.1  
User Console  
The settings for the User Consoler are user specific. Meaning the super user can customize  
these settings for each user separately. Changing the settings for one user does not affect the  
settings for the other users.  
Figure 6-5: User Console Settings (Part 1)  
User select box: This selection box displays the user ID which is being modified. The “super”  
user can change the settings of other users.  
Transmission Encoding: The Transmission Encoding setting changes the image-encoding  
algorithm that is used to transmit the video data to the Remote Console window. It is possible to  
optimize the speed of the remote screen depending on the number of users working at the same  
time and the bandwidth of the connection (Modem, ISDN, DSL, LAN, etc.).  
Automatic detection: The encoding and the compression level is determined automatically  
from the available bandwidth and the current content of the video image.  
Pre-configured: The pre-configured settings deliver the best result because of optimized  
adjustment of compression and colour depth for the indicated network speed.  
Manually: Allows both the compression rate and the colour depth to be adjusted individually.  
Depending on the selected compression rate the data stream between the freeView IP 800  
and the Remote Console will be compressed in order to save bandwidth. Increasing the  
compression rate requires more resources from the freeView IP 800, thus should not be used  
49  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
freeView IP 800 User’s Manual  
when multiple users are accessing the remote console simultaneously. The default color  
depth is 16 Bit (65536 colors). The other color depths are intended for slower network  
connections since they require less bandwidth. Therefore compression level 0 (no  
compression) uses only 16 Bit color depth. At lower bandwidths, only 4 Bit (16 colors) and 2  
Bit (4 gray scales) are recommended for typical desktop interfaces. Photo-quality pictures  
have best results with 4 Bit (16 gray scales). 1 Bit color depth (black/white) should only be  
used for extremely slow network connections.  
Figure 6-6: User Console Settings (Part 2)  
Remote Console Type: Specifies which Remote Console Viewer to use, the Default  
Java-Virtual Machine or Sun Microsystems Java Browser Plug-in.  
Default Java VM: Selects the default Java Virtual Machine of the Browser. This may be the  
Microsoft JVM or the Sun JVM depending on the configuration. Use of the Sun JVM may also  
be forced by selecting Sun Microsystems Java Browser Plug-in  
Sun Microsystems Java Browser Plugin: Instructs the web browser of the local system to  
use the JVM from Sun Microsystems. The JVM in the browser is used to run the code for the  
Remote Console window, which is a Java Applet. If this box is checked and the appropriate  
Java plug-in is not already installed on the system, it will be downloaded and installed  
automatically. Once installation begins, follow the step by step instructions in install the virtual  
machine. The advantage of downloading Sun's JVM is that it provides a stable and identical  
Java Virtual Machine across different platforms. The Remote Console software is optimized  
for this JVM version and offers a wider range of functionality when run in Sun's JVM.  
50  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
freeView IP 800 User’s Manual  
Miscellaneous Remote Console Settings:  
Start in Monitor Mode: Sets the initial value for the monitor mode. By default the monitor  
mode is off. If this feature is turned on, the Remote Console window will start in read only  
mode.  
Start in Exclusive Access Mode: Enables exclusive access mode immediately at Remote  
Console startup. This forces the Remote Consoles of all other users to close. No one can  
open the Remote Console at the same time again until this user disables exclusive access or  
logs off.  
Mouse Hotkey: Allows the user to specify a hotkey combination which starts either the mouse  
synchronization process if pressed in the Remote Console, or is used to leave the single mouse  
mode.  
Remote Console Button Keys: Button Keys allow simulating keystrokes on the remote system  
that cannot be generated locally. The reason for this might be a missing key on the keyboard or  
that the operating system on the local machine is catching this keystroke already. Typical  
examples are <Control>+<Alt>+<Delete> and <Alt>+<Tab> on Windows and DOS, what are  
always caught locally, or <Control>+<Backspace> on Linux for terminating the X-Server. The  
syntax to define a new Button Key is as follows:  
[confirm] <keycode>[+|-[*]<keycode>]*  
“confirm” requests confirmation by a dialog box before the key strokes will be sent to the remote  
host.  
“keycode” is the key to be sent. Multiple key codes can be concatenated with a plus, or a minus  
sign. The plus sign builds key combinations, all keys will be pressed until a minus sign or the end  
of the combination is encountered. In this case all pressed keys will be released in reversed  
sequence. The minus sign builds single, separate key presses and releases. The star inserts a  
pause with duration of 100 milliseconds.  
51  
Download from Www.Somanuals.com. All Manuals Search And Download.  
freeView IP 800 User’s Manual  
6.3.2  
Keyboard/Mouse  
Figure 6-7: Keyboard and Mouse Settings  
Host Interface: Sets which interface the mouse is connected to. The choices are “Auto” for  
automatic detection, “USB” for a USB mouse, and “PS/2” for a PS/2 mouse.  
Note: To use the USB and/or PS/2 interface, the correct cabling (USB and/or PS/2) needs to be  
connected between the freeView IP 800 and the host server. If the managed host does not  
support USB keyboards at the BIOS level, and a USB interface is being used, remote keyboard  
access will not be available during the boot process of the host. If both USB and PS/2 interfaces  
are connected and “Auto” is selected as the host interface, the device will select “USB” if  
available; otherwise it falls back to “PS/2”.  
To have USB remote keyboard access during the boot process of the host, the following  
conditions must be fulfilled:  
The host BIOS must have USB keyboard support  
The USB cable must be connected and must be selected in the Host interface option  
PS/2 Keyboard Model: Selects the keyboard layout. Available options are “Generic 101-Key  
PC” for a standard keyboard layout, “Generic 104-Key PC” for a standard keyboard layout  
extended by three additional windows keys, “Generic 106-Key PC” for a Japanese keyboard, and  
“Apple Macintosh” for an Apple Macintosh keyboard.  
USB Mouse Type: Selects the USB mouse type. Available options are “MS Windows 2000 or  
52  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
freeView IP 800 User’s Manual  
newer” for MS Windows 2000 or Windows XP, or “Other Operating Systems” for MS Windows NT,  
Linux, or OS X. In “MS Windows 2000 or newer” mode the remote mouse is always synchronized  
with the local mouse.  
Mouse Speed:  
Auto mouse speed: Select this option if mouse acceleration is enabled on the host system.  
The freeView IP 800 will try to detect the acceleration and speed of the mouse during the  
mouse sync process.  
Fixed mouse speed: Use a direct translation of mouse movements between the local  
mouse and the remote pointer.  
A fixed scaling can also be set which determines the number of pixels the remote mouse pointer  
is moved when the local mouse pointer is moved by one pixel. This option only works when the  
mouse settings on the host are linear (i.e. mouse acceleration is disabled).  
6.3.3  
Video  
Figure 6-8: Video Settings  
Miscellaneous Video Settings  
Noise filter: This option defines how the freeView IP 800 reacts to small changes in the  
video input signal. A large filter setting uses less network traffic and leads to a faster video  
display, but small changes in the display may not be recognized and updated on the remote  
immediately. A small filter setting displays all changes on the remote host instantly but will  
produce more network traffic (depending on the quality of the video input signal). In general,  
the default setting should be suitable for most situations.  
Force Composite Sync (Required for Sun Computers): To support signal transmission  
from a Sun machine, enable this option. If not enabled, the picture of the remote console will  
not be visible.  
53  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
freeView IP 800 User’s Manual  
6.4 Device Settings  
The Device Settings menu allows the user to configure the freeView IP 800 itself.  
6.4.1  
Network  
The Network Settings panel as shown in Figure 6-9 allows network related parameters to be  
changed. Each parameter will be explained below. Once applied the new network settings will  
immediately come into effect.  
Note: See Section 4 for instructions on installing the freeView IP 800 initially.  
Note: Changing the device’s network settings may result in loss of connection if the supplied  
network settings are incorrect.  
Figure 6-9: Network Settings  
IP auto configuration: This option determines if the device should get its network settings from  
a DHCP or BOOTP server, or none at all (manual IP address). For DHCP, select “dhcp”, and for  
BOOTP select “bootp” accordingly. If “none” is selected, then IP auto configuration is disabled.  
IP address: The IP address in of the unit.  
Subnet Mask: The subnet mask of the local network.  
Gateway IP address: In order for the freeView IP 800 to be accessible from networks other than  
the local network, this IP address must be set to the local network router's IP address.  
Primary DNS server IP Address: IP address of the primary Domain Name Server. If this field is  
empty, the unit will not be able to perform name resolution.  
54  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
freeView IP 800 User’s Manual  
Secondary DNS server IP Address: IP address of the secondary Domain Name Server. It will  
be used if the Primary DNS Server cannot be contacted.  
Remote Console and HTTPS port: Port number which the device’s Remote Console server  
and HTTPS server are listening on. If left empty the default value will be used.  
HTTP port: Port number which the device’s HTTP server is listening on. If left empty the default  
value will be used.  
Telnet port: Port number which the device’s Telnet server is listening on. If left empty the default  
value will be used.  
Bandwidth limitation: The maximum network traffic generated by the device. Value in kbit/s.  
Enable Telnet access: Select this option to allow access to the freeView IP 800 using the Telnet  
Gateway see Section 6.5.5 for more details.  
Disable Setup Protocol: Enable this option to exclude the freeView IP 800 from the setup  
protocol.  
6.4.2  
Dynamic DNS  
Figure 6-10: Dynamic DNS  
A freely available Dynamic DNS service (e.g. dyndns.org) can be used in the scenario shown in  
Figure 6-11:  
55  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
freeView IP 800 User’s Manual  
Figure 6-11: Dynamic DNS Scenario  
The freeView IP 800 is reachable from the internet via the IP address of the DSL router, which is  
dynamically assigned by the service provider. Since the administrator does not know the IP  
address assigned by the provider at any given time, the freeView IP 800 connects to a special  
dynamic DNS server at regular intervals and registers its IP address there. The administrator can  
then contact the dynamic DNS server and find the IP address of the device.  
The administrator has to register the device that is with the Dynamic DNS service provider and  
assign a hostname (URL) to it. The Dynamic DNS service provider will assign a nickname and a  
password to the administrator. The hostname and the account information are needed to  
determine the IP address of the registered device.  
The following steps detail how to enable Dynamic DNS:  
Ensure that the LAN interface of the freeView IP 800 is properly configured.  
Enter the Dynamic DNS Settings configuration dialog as shown in Figure 6-10.  
Enable Dynamic DNS and specify the settings appropriately (see below).  
Enable Dynamic DNS: This enables the Dynamic DNS service. This requires a configured DNS  
server IP address.  
Dynamic DNS server: This is the name of the server where the device registers itself at regular  
intervals. Currently, this is a fixed setting since only dyndns.org is presently supported.  
Hostname: This is the hostname of the device that is provided by the Dynamic DNS Server. Use  
the whole name including the domain, (e.g. testserver.dyndns.org), not just the actual hostname.  
56  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
freeView IP 800 User’s Manual  
Username: The username provided by the Dynamic DNS Server. Spaces are not allowed in the  
username.  
Password: The password provided by the Dynamic DNS Server.  
Check time: The time which the device registers itself with the Dynamic DNS server.  
Check interval: The time interval which the device registers itself with the Dynamic DNS based  
on the Check time parameter above.  
Note: The freeView IP 800 has its own independent real-time clock. Ensure the time setting on  
the device is correct; see the section titled “Date and Time”.  
6.4.3  
Security  
Figure 6-12: Device Security  
Force HTTPS: When enabled, this option restricts access to the web interface to HTTPS  
connections only. The freeView IP will not listen on the HTTP port for incoming connections.  
For instructions on creating a customer SSL certificate that is used to identify the freeView IP 800,  
see the Section 6.5.4 titled “Certificate”.  
KVM encryption: This option controls the encryption of the RFB protocol. RFB is used by the  
Remote Console to transmit both the screen data to the administrator machine and keyboard  
and mouse data back to the host. If set to “Off”, no encryption will be used. If set to “Try”, the  
applet tries to create an encrypted connection. If an encrypted connection cannot be made, an  
unencrypted connection will be used. If set to “Force”, the applet tries to create an encrypted  
connection. If an encrypted connection cannot be made, an error will be reported.  
57  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
freeView IP 800 User’s Manual  
6.4.4  
Certificate  
Figure 6-13: Certificate Settings  
The freeView IP 800 uses the Secure Socket Layer (SSL) protocol for any encrypted network  
traffic between itself and a connected client. During the connection establishment, the device has  
to expose its identity to a client using a cryptographic certificate. By default, this certificate and  
the underlying secret key is the same for all freeView IP 800’s and will not match the network  
configuration that will the device is connected to. The certificate's underlying secret key is also  
used for securing the SSL handshake. Hence, there is still a potential security risk when using  
the default SSL certificate, but it is more secure than no encryption at all.  
It is possible to generate and install a new certificate that is unique for a particular freeView IP  
800. In order to do this, the freeView IP 800 can generate a new cryptographic key and the  
associated Certificate Signing Request (CSR) that needs to be certified by a certification  
authority (CA). A certification authority verifies that the device and identity are legitimate and  
signs and issues a SSL certificate for the device.  
The following steps are necessary to create and install a SSL certificate for the freeView IP 800:  
Create an SSL Certificate Signing Request using the panel shown in Figure 6-13. Complete  
the fields on the page. The fields are explained below. Once completed, click on the “Create”  
button which will initiate the Certificate Signing Request generation. The CSR can be  
downloaded to the local machine with the “Download CSR” button (see Figure 6-14).  
Send the saved CSR to a CA for certification. Once the CA has completed their  
authentication process, a new certificate will be issued for the device.  
58  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
freeView IP 800 User’s Manual  
Upload the certificate to the freeView IP 800 using the “Upload” button as shown in Figure  
6-14.  
Figure 6-14: SSL Certificate Upload  
After completing these three steps, the freeView IP 800 will have its own certificate that is used  
for identifying the card to its clients.  
Note: If the CSR on the device is lost or destroyed, it cannot be recovered. The steps above  
must be completed again in order to obtain a new certificate.  
Common name: This is the network name of the freeView IP 800 once it is installed in the  
network (usually the fully qualified domain name). It is identical to the name that is used to  
and the actual network name differ, the browser will pop up a security warning when the unit is  
accessed using HTTPS.  
Organizational unit: This field is used for specifying which department within an organization  
owns the device.  
Organization: The name of the organization.  
Locality/City: The city where the organization is located.  
State/Province: The state or province where the organization is located.  
Country (ISO code): The country where the organization is located. This is the two-letter ISO  
code, e.g. DE for Germany, CA for Canada, or US for the USA.  
Challenge Password: Some certification authorities require a challenge password to authorize  
later changes to the certificate (e.g. revocation of the certificate). The minimum length of this  
59  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
freeView IP 800 User’s Manual  
password is 4 characters.  
Confirm Challenge Password: Confirmation of the Challenge Password  
Email: The email address of a contact person that is responsible for the unit and its security.  
Key length: This is the length of the generated key in bits. 1024 Bits is sufficient for most cases.  
Longer keys may result in slower response time of the device during connection establishment.  
6.4.5  
Serial Port  
Figure 6-15: Serial Port  
The freeView IP 800’s Serial Settings (Figure 6-15) allows the user to specify what type of device  
is connected to the serial port and how to use it.  
Configuration or console login: Do not use the serial port for any special function; use it only  
for the initial configuration (see Table 4-1).  
Modem: The freeView IP 800 offers remote access using a telephone line in addition to the  
standard access over the Ethernet network. The modem needs to be connected to the serial  
interface of the freeView IP 800.  
A user can connect to the freeView IP 800 using a telephone line the same way that it would  
connect to an Internet Service Provider (ISP). By dialing the telephone number of the modem  
using third-party modem software on the local computer, the user can connect to the device  
through normal telephone lines. The connection is established using the Point-to-Point Protocol  
(PPP). Before connecting to the device, ensure that the console computer is configured correctly.  
For instance, Windows based operating systems default to PPP for dial-up network connections,  
which is correct.  
60  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
freeView IP 800 User’s Manual  
The Modem Settings panel sets the parameters used by the client to connect to the device. An  
explanation of the parameters is included below.  
Serial line speed: The speed the freeView IP 800 uses to communicate with the modem.  
Most modems available today will support the default value of 115200 bps. If an older modem  
is used and problems occur, try lowering this value.  
Modem init string: The initialization string used by the freeView IP 800 to initialize the  
modem. The default value will work with all standard modern modems directly connected to a  
telephone line. If a special modem is used or if the modem is connected to a local telephone  
switch that requires a special dial sequence to establish a connection to the public telephone  
network, change this setting by entering the correct a new string. Refer to the modem's  
manual about the AT command syntax to use.  
Modem server IP address: This IP address will be assigned to the freeView IP 800 itself  
during the PPP handshake. Since it is a point-to-point IP connection, almost any IP address  
is permitted, but it cannot be the same as the Ethernet connection of the device or the client.  
The default value will work in most cases.  
Modem client IP address: This IP address will be assigned to the console computer during  
the PPP handshake. Since it is a point-to-point IP connection, almost any IP address is  
permitted, but it cannot be the same as the Ethernet connection of the device or the client.  
The default value will work in most cases.  
Pass-through access to serial port via Telnet: If this option is enabled, a device with a serial  
interface (e.g. a managed switch) can be controlled by the local computer. Select the  
appropriate options for the serial port and use the Telnet Console, or a standard Telnet client to  
connect to the device.  
61  
Download from Www.Somanuals.com. All Manuals Search And Download.  
freeView IP 800 User’s Manual  
6.4.6  
Date And Time  
Figure 6-16: Date and Time  
This page allows the user to set the internal real-time clock of the freeView IP 800 switch can be  
set up (Figure 6-16). The time can be set manually or using an NTP (Network Time Protocol)  
server. If an NTP server is not used, the internal clock will need to be reset if the unit loses power  
for several minutes. The alternative is to use an NTP server, which set up the internal clock  
automatically to the current UTC (Coordinated Universal Time, also known as GMT) time.  
Because the NTP server time is always UTC, the UTC offset must be correct in order for the  
device to have the correct time.  
Note: The device does not adjust for daylight savings time automatically, so the UTC offset will  
have to be adjusted manually for daylight savings time.  
62  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
freeView IP 800 User’s Manual  
6.4.7  
Event Log  
Figure 6-17: Event Log  
Important events such as a login failure or a firmware update are logged to a selection of logging  
destinations (see Figure 6-17). Each of these events belongs to an event group, which can be  
selected separately.  
List logging enabled: This is the main method to log events. This method uses the internal log  
list of the freeView IP 800. To display the log, click on “Event Log” under the “Maintenance” menu.  
The number of log entries shown per page can be changed in this section, and the log can also  
be cleared by clicking the “Clear” button.  
Note: The maximum number of events that can be recorded in the log is 1000. Any entry added  
above this will overwrite the oldest entry in the log. Also, if the device is reset through the web  
interface, the log information will be stored. However, if the device loses power or a hard reset is  
performed, the log will be cleared.  
NFS Logging enabled: If this option is selected, the freeView IP 800 will export the log  
information to a directory or static link on an NFS server. To write log data from more than one  
freeView IP 800 to the same NFS share, a unique file name must be defined for each device.  
Once the NFS settings are complete, click the “Apply” button. The NFS share will be mounted  
immediately. If the NFS share and the NFS server are not available, an error message will  
appear.  
63  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
freeView IP 800 User’s Manual  
Note: Unlike the internal log file, the size of the NFS log file is not limited by the device. Every log  
event will be appended to the end of the file so it will grow continuously. Remember to clean out  
old log entries from the file regularly.  
SMTP Logging enabled: If this option is selected, the freeView IP 800 will e-mail the log to an  
e-mail address specified in the Sender Email Address field. These e-mails contain the same  
information as the internal log file and the mail subject is filled with the event group of the  
occurred log event. In order to use this feature, an SMTP server must be specified which is  
accessible by the device and does not require authentication. The information should be entered  
in the following format:  
<serverip>:<port>  
SNMP Logging enabled: If this option is selected, the freeView IP 800 will send an SNMP trap  
to a specified destination IP address every time a log event occurs. If the receiver requires a  
community string, it can be set in the appropriate text field. Most of the event traps only contain  
one descriptive string with all information about the log event. Only authentication and host  
power events have their own trap class that consists of several fields with detailed information  
about the event. A third party SNMP monitor is required to receive the traps.  
64  
Download from Www.Somanuals.com. All Manuals Search And Download.  
freeView IP 800 User’s Manual  
6.5 Maintenance  
6.5.1  
Device Information  
Figure 6-18: Device Information  
Board Summary  
This section contains a summary with various information about the IP-KVM and its current  
firmware and allows you to reset the card. You may have a look at Figure 6-18 for an example.  
The Data file for support allows you to download the IP-KVM data file with specific support  
information. This is an XML file with certain customized support information like the serial  
number etc. You may send us this information together with a support request. It will help us to  
locate and solve your reported problem.  
Figure 6-19: Connected Users  
65  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
freeView IP 800 User’s Manual  
Connected Users  
This section shows which users are connected to the device. The user’s name, IP address, and  
current status are displayed. The letters “RC” beside a user’s name means that the Remote  
Console is open. If the Remote Console is opened in exclusive mode, the term (exclusive) will be  
displayed.  
Reset Functions  
This section allows you to reset specific parts of the device. Currently this involves the video  
engine and the PS/2 IP-KVM switch itself. Resetting the card itself is mainly needed to activate a  
newly updated firmware. It will close all current connections to the administration console and to  
the Remote Console. The whole process will take about half a minute. Resetting sub devices  
(e.g. video engine) will only take a few seconds and will not result in closing connections. This  
section contains summary information about the device and its current firmware.  
The Connected Users section shown in Figure 6-19 shows which users are connected to the  
device. The user’s name, IP address, and current status are displayed. The letters “RC” beside a  
user’s name means that the Remote Console is open. If the Remote Console is opened in  
exclusive mode, the term (exclusive) will be displayed.  
66  
Download from Www.Somanuals.com. All Manuals Search And Download.  
freeView IP 800 User’s Manual  
6.5.2  
Event log  
Figure 6-20: Event Log List  
Figure 6-20 shows the log list including events that are logged by the freeView IP 800.  
67  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
freeView IP 800 User’s Manual  
6.5.3  
Update Firmware  
Figure 6-21: Update Firmware  
The freeView IP 800 is a complete standalone device. The software that runs on the device is  
called the firmware. The firmware of the freeView IP 800 can be updated remotely in order to add  
new functionality or special features.  
A new firmware update is a binary file which can be found on the freedom9 website at  
to unzip the file. Other operating systems will have their own unzip programs.  
Before updating the firmware of the device, the new uncompressed firmware file has to be saved  
on the local machine.  
To update the firmware, follow these steps:  
Save the firmware file on the local computer.  
Type in the path and filename of the firmware file, or click “Browse…” and search for the file  
on the system.  
Click “Upload”.  
68  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
freeView IP 800 User’s Manual  
Once the firmware file has been uploaded, it is checked to see if it is a valid firmware file and  
whether there were any transmission errors. In the case of an error, the Upload Firmware  
function will be aborted.  
Verify the new version of the firmware, and click “Update”. Note: This process is non  
reversible and might take a few minutes. Make sure the freeView IP 800 is not powered off  
during the update process; otherwise the device may be permanently damaged.  
After the firmware has been saved, a prompt will appear to reset the device manually. After  
the unit is reset, the new firmware will be loaded. However, the user will have to log into the  
unit again.  
Note: The firmware update procedure is thorough in looking for errors and inconsistencies,  
reducing the chances of an error occurring. However, only experienced staff or administrators  
should perform a firmware update. Ensure that the device is not powered off during the  
firmware upgrade.  
6.5.4  
Unit Reset  
Figure 6-22: Unit Reset  
This section allows the user to reset specific parts of the device. The parts include: the keyboard  
and mouse, the video engine, and the entire device itself. Resetting the device itself is mainly  
needed to activate a newly updated firmware. It will close all current connections to the  
69  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
freeView IP 800 User’s Manual  
administration console and to the Remote Console. The whole process will take about half a  
minute. Resetting sub devices (e.g. video engine) will take only a few seconds and does not  
result in closing connections.  
Note: Only the super user is allowed to reset the device.  
70  
Download from Www.Somanuals.com. All Manuals Search And Download.  
freeView IP 800 User’s Manual  
7 Troubleshooting  
Ensure that all cables are well seated. Label all of the cables with the number for each  
respective computer to avoid confusion.  
The recommended maximum KVM cable length is 5 meters (16 ft), a longer cable may result  
in ghosting and degradation. Normally, the cable length is based on the driver capacity of  
your VGA card and your motherboard PS/2 port. If you need a longer VGA cable, please use  
a VGA and PS/2 extender.  
The Power Jack polarity is center positive and the power adapter is DC5V, 2.5A.  
If you forget your “password” and it is changed from the default, please contact your supplier.  
Q 001: The remote mouse doesn’t work or is not synchronized.  
A 001: Make sure the mouse settings on the device match the mouse model. There are some  
circumstances where the mouse synchronization process could behave incorrectly, refer to  
Section 5.10.1 for more details.  
Q 002: The video quality is bad or the picture is grainy.  
A 002: Try to correct the brightness and contrast settings (see Section 6.3.3) until the picture  
improves. Use the auto adjustment feature to correct a flickering video.  
Q 003: Can’t log into the freeView IP 800.  
A 003: Verify the username and password. Be default, the user ”super” has the password ”pass”.  
Also, ensure that the web browser is configured to accept cookies.  
Q 004: The Remote Console window can’t connect to the host.  
A 004: A firewall may be preventing access to the Remote Console. Make sure that TCP port  
numbers 80 or 443 are open for incoming TCP connection establishments.  
Q 005: No connection can be established to the freeView IP 800.  
A 005: Check whether the network connection is working (ping the IP address of device). If not,  
check the network hardware and check if the device is powered on. Check whether the IP  
address of the device and all other IP related settings are correct. Check that there isn’t an IP  
conflict on the network (multiple devices using the same IP address). Verify that the entire IP  
infrastructure of your LAN, like routers etc., are correctly configured.  
Q 006: Special key combinations, e.g. <Alt>+<F2>, <Alt>+<F3> are intercepted by the console  
system and not transmitted to the host.  
A 006: A ’Hot-key’ needs to be defined for special key combinations. See Section 5.10.1 for more  
71  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
freeView IP 800 User’s Manual  
details.  
Q 007: The web interface of the device looks abnormal.  
A 007: Ensure the web browser cache settings are correct. Particularly, check that the cache  
settings are not set to ”Never check for newer pages”. Otherwise, the device interface may be  
loaded from the browser cache and not from the device.  
Q 008: Windows XP doesn’t awake from standby mode.  
A 008: This is likely a Windows XP problem. Try not to move the mouse when XP goes into  
standby mode.  
Q 009: Can’t upload the signed certificate in MacOS X.  
A 009: If an ’internal error’ occurs while uploading the signed certificate, either change the  
extension of the file to .txt or add a file helper using the Internet Explorer preferences for this type  
of file. Make sure that the encoding is plain text and the checkbox ’use for outgoing’ is checked. If  
this does not work, try using a Mozilla based browser.  
Q 010: Every time I open a dialog box with some buttons, the mouse pointers are not  
synchronous anymore  
A 010: Ensure that the feature “Automatically move mouse pointer to the default button of dialog  
boxes” is disabled on the host system.  
Q 011: The computer boots up fine, but the keyboard doesn’t work  
A 011: Make sure the keyboard works when directly plugged into the computer. Don’t press any  
keys on the keyboard while the selected computer is booting up. Otherwise, it might cause a  
keyboard error. Try a different keyboard, but use only a 101, 102 or 104-key keyboard.  
Q 012: The power switch is off, but the switch is still on or power adapter is unplugged from the  
switch, but the switch is still on.  
A 012: The freeView IP 800 draws the power source from the power adapter and the connected  
PC’s PS/2 port. On some PC’s the PS/2 port can supply enough power for the switch, but some  
PC’s PS/2 port (like laptop, notebook computer…etc.) cannot supply enough power for the  
switch. For more reliable performance, please do not set the power switch to off state or remove  
the power adapter from the switch.  
72  
Download from Www.Somanuals.com. All Manuals Search And Download.  
freeView IP 800 User’s Manual  
7.1 Certificates  
FCC  
This equipment has been tested and found to comply with Part 15 of the FCC Rules. Operation  
is subject to the following two conditions:  
(1) This device may not cause harmful interference  
(2) This device must accept any interference received. Including interference that may cause  
undesired operation.  
CE – Certificate  
This equipment is in compliance with the requirements of the following regulations: EN 55 022:  
CLASS B  
73  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
A. Pin Assignments  
A.1 VGA HD-15  
A.2 RJ 45 Connector Ethernet  
A.3 RJ 45 Connector ISDN  
Same as above.  
A.4 Serial SUB-D 9 Connector 1  
74  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
freeView IP 800 User’s Manual  
A.5 KVM 15 pin connector  
B. Key Codes  
Table B-1 shows the key codes used to defines keystrokes or hotkeys for several functions. Note  
that these key codes do not represent necessarily key characters that are used on international  
keyboards. The names are based on a standard 104 key PC keyboard with an US English  
language mapping. The layout for this keyboard is shown in Figure B-1. However, most modifier  
keys and other alphanumeric keys used for hotkey purposes in application programs are in the  
same position as a US English keyboard, no matter what language mapping is used. Some of  
the keys have aliases which means they can have 2 different key codes (separated by a comma  
in the table).  
75  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Figure B-1: English (US) Keyboard Layout  
Keys and Aliases  
0 – 9  
SPACE  
ALTGR  
PAGE DOWN  
UP  
A - Z  
~, TILDE  
ESCAPE, ESC LEFT  
-, MINUS  
F1  
DOWN  
=, EQUALS  
F2  
RIGHT  
;
F3  
NUM LOCK  
NUMPAD0  
NUMPAD1  
NUMPAD2  
NUMPAD3  
NUMPAD4  
NUMPAD5  
NUMPAD6  
NUMPAD7  
NUMPAD8  
F4  
<, LESS  
F5  
,
F6  
.
F7  
/, SLASH  
BACK SPACE  
TAB  
F8  
F9  
F10  
F11  
F12  
[
]
ENTER  
PRINTSCREEN NUMPAD9  
CAPS LOCK  
\, BACK SLASH  
LSHIFT, SHIFT  
RCTRL  
SCROLL LOCK NUMPADPLUS,NUMPAD PLUS  
BREAK  
INSERT  
HOME  
NUMPAD/  
NUMPADMUL, NUMPAD MUL  
NUMPADMINUS, NUMPAD MINUS  
NUMPADENTER  
WINDOWS  
RSHIFT  
LCTRL, CTRL  
LALT, ALT  
PAGE UP  
DELETE  
END  
MENU  
Table B-1: Key Names  
76  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
freeView IP 800 User’s Manual  
C. Video Modes  
Table C-1 lists the video modes supported by the freeView IP 800. Do not use custom video  
settings besides that are not listed in the following table. Otherwise the freeView IP 800 may not  
be able to detect them.  
Resolution (x, y) Refresh Rates (Hz)  
640 x 350  
640 x 400  
640 x 480  
720 x 400  
800 x 600  
832 x 624  
1024 x 768  
1152 x 864  
1152 x 870  
1152 x 900  
1280 x 960  
1280 x 1024  
70, 85  
56, 70, 85  
60, 67, 72, 75, 85, 90, 100, 120  
70, 85  
56, 60, 70, 72, 75, 85, 90, 100  
75  
60, 70, 72, 75, 85, 90, 100  
75  
75  
66  
60  
60, 75  
Table C-1: Supported Video Modes  
D. Rack Mount Kit Installation Diagram  
Figure D-1: Rack Mount Installation Diagram  
77  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 

Earthquake Sound Car Amplifier T1000W 2 User Manual
Everpure Water System CGS 22 User Manual
Fellowes Paper Shredder C 220i C 220Ci User Manual
Frigidaire Dehumidifier 66129900901 User Manual
Furuno Radar Detector FAR2167DS BB User Manual
GE Answering Machine 347A8232 0001 User Manual
GE Blender 169169 User Manual
GE Freezer ZIFP360NX User Manual
Global Upholstery Co Indoor Furnishings Supra X User Manual
G Technology Server 0G01873 User Manual