Flowtron Outdoor Products Insect Control Equipment PV 440 User Manual

PV-440  
OWNER’S  
MANUAL  
IMPORTANT  
Read this manual completely  
before installing or operating your  
new Mosquito Galaxie PowerVac.  
Look for this symbol to point  
out important safety precautions.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5. Install MA-1000 Octenol Attractant Cartridge:  
c. Pull bulb out of its socket.  
d. Insert replacement bulb.  
U.S. Government and university researchers have demon-  
strated that octenol, a component of human respiration, is  
an attractant to mosquitoes and bitingi e s .  
e. Close hood and secure with latch  
f. Connect power cord and return switch to the “on” position.  
Use only Flowtron BF-200 replacement bulbs available  
The Galaxie PowerVac uses a specially designed time  
release cartridge containing octenol (1-OCTEN-3-OL).  
Install the Octenol Cartridge as follows:  
4. Axel Fan and Funnel:  
a. Release the hood latch by pulling top of latch forward.  
Clean the axel fan and funnel each time the octenol car-  
tridge is replaced or more often during periods of heavy  
insect infestation.  
b. Raise the hood up to a vertical position.  
illustration 4  
c. Remove the octenol cartridge  
from its package and peel off  
the adhesive label covering the  
evaporation holes.  
Cleaning  
Brush  
CAUTION  
Always disconnect the power cord from its electrical  
source before serv i c i n g , handling or cleaning the unit.  
d. Place the cartridge in the rec-  
tangle well in the center of the  
plenum with the evaporation  
holes facing upward.  
Octenol  
To clean the Fan and Funnel, open the hood latch and lift  
the hood to an upright position.  
See Illustration 4.  
a. Clean fan blades and area between the fan blades and  
the surrounding fan housing using the cleaning brush  
provided. The brush is located behind the Octenol well.  
Simply slide the brush out from its stored location.  
When complete place cleaning brush back in its proper  
storage location.  
e. Close hood and secure the  
hood latch.  
Plenum  
6. Position and screw power pack to either an outside or  
inside wall adjacent to a 115/120 volt A.C. outlet (screws  
not provided). Run the low voltage wire either above or  
below ground from the power pack to the unit. Plug the  
low voltage wire into the power cord connector located at  
the bottom of the PowerVac. Plug the power pack into the  
electrical outlet.  
See illustration 4.  
b. To clean the funnel, remove the collection tray and then  
Figure A  
Push rear of bottom funnel  
ring up into the unit’s housing  
until front tabs become  
disengaged from housing.  
See figure A.  
7. Place the switch located at the rear on the underside of  
the unit adjacent to the power cord to the “on”position.  
Up  
Housing  
Front  
Tab  
Note: Hood must be down and latched to ensure  
that the built-in interlock is engaged and will allow  
power to come on.  
Bottom  
Funnel  
Ring  
Pull funnel down and forward  
releasing rear section of upper  
funnel surface and remove  
funnel from unit. See figure B.  
Push Up Here  
Down  
Figure B  
When the power is applied, the ultraviolet blacklight-blue  
bulb will emit a bluish glow, the axial fan will rotate, the  
four colored LED’s will light and oscillate and the built-in  
heater will heat the entry louver to body temperature.  
Remove insect debris from  
screen surrounding funnel.  
Wash screen with water and  
shake off excess water before  
re-installing.  
Forward  
Tabs  
Upper  
Funnel  
Surface  
Maintenance  
1. Collection Tray:  
Empty the collection tray periodically to ensure proper air  
flow through the trap. To remove the collection tray, push  
in on the latch at the front of the tray and pull tray down.  
Figure C  
Re-install funnel by holding  
funnel at a slight angle and  
inserting the front edge of the  
upper funnel surface inside of  
unit’s housing. See figure C.  
2. Octenol Cartridge:  
Front  
Edge  
of Upper  
Funnel Surface  
Up  
Replace the octenol cartridge after approximately three  
weeks of Galaxie PowerVac usage.  
3. Ultraviolet Blacklight-Blue Bulb:  
Figure D  
Push funnel upwards and with  
the rear section of the bottom  
funnel ring at a slight angle  
compress funnel until front  
tabs of bottom funnel ring are  
up inside of the housing.  
See figure D.  
To replace the blacklight-blue bulb:  
NOTE U l t r aviolet or “blacklight” is invisible to the  
eye, and its ability to attract insects diminishes ov e r  
time. Therefo r e, although the bulb appears to be  
functioning it should be replaced ev e ry season to  
maintain optimal “blacklight” effectiveness.  
Up  
a. Place on/off switch to the ”off” position and disconnect  
power cord.  
Close hood, secure with latch, connect power cord and  
return the on/off switch to the “on” position.  
b. Open hood latch and raise hood to an upright position.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Warranty  
PV-440 Trouble Shooting Chart  
Symptom  
Probable Cause  
1. No power at outlet.  
Remedy  
Ultraviolet bulb, fan and  
colored LED’s do not  
function.  
1. Check for 110-120 Volts AC power at outlet.  
2. Hood interlock switch not closed.  
2. Check for proper latching of hood.  
3. Unit not properly connected to its  
power pack.  
3. Check plug connections between unit and power pack low  
voltage wire.  
The fan does not run.  
1. Fan clogged with insect debris.  
1. Clean fan. (See “Maintenance” section of owner’s manual).  
1. Engage the funnel end with the collection tray nozzle opening.  
No dead insects or insect  
debris in collection tray.  
1. Funnel end is not over collection tray  
nozzle opening.  
2. Clean fan and funnel. (See “Maintenance” section of owner’s manual).  
2. Fan and/or funnel clogged with insect debris.  
1. Current mosquito population not readily  
attracted to the PowerVac.  
Not catching mosquitoes.  
1. Notably the day flying Asian tiger Mosquito. Operate the unit with the  
Octenol cartridge removed.  
2. Trap is not located in a productive site.  
2. Move trap to a new site. (See “Placement” section of owner’s manual).  
Any problems you encounter that are not corrected by the action recommended in the trouble shooting chart should be referred to the  
Flowtron Service Department, 1-800-343-3280.  
Accessories  
Accessories are available at your local retail outlet or by ordering on-line at  
Extension Cord – EC-50  
Mosquito Attractant: – MA 1000  
Slow release Octenol Cartridge  
makes your Galaxie PowerVac more effective in  
attracting mosquitoes and biting flies.  
50 foot low voltage extension cord.  
Allows placement of the Galaxie  
PowerVac an additional 50 feet away  
from the power source.  
Mosquito Attractant Six Pack: – MA 1000-6  
Flowtron Outdoor Products, 15 Highland Ave, Malden, MA 02148  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Electro Voice Microphone 634B User Manual
Euro Pro Fryer F1052 User Manual
Extron electronic Switch CC AAP Series User Manual
First Alert Home Security System 2074EF User Manual
Fisher Price Doll C5352 User Manual
Fostex Recording Equipment XR 3 User Manual
Frigidaire Cooktop FGGC3645K S W B User Manual
FujiFilm Digital Camera 16404791 User Manual
FujiFilm Film Camera AF3 177E User Manual
Gaggenau Cooktop KG 291 110 CA User Manual