INSTALLATION INFORMATION
GC36 and GC901 SERIES
GAS COOKTOP
IMPORTANT! Please make this information available to the person responsible for installing this cooktop as it could reduce your installation costs.
To the installer: Please leave these instructions with the appliance. Inform the customer to
retain for future reference.
CAUTION
IN ORDER TO AVOID A HAZARD THESE APPLIANCES MUST BE INSTALLED ACCORDING TO
THESE INSTRUCTIONS.
Please follow installation information carefully. If in doubt consult your local building
regulations, local gas authority codes and electrical regulations.
This product should not be sealed into the bench with silicone or glue. This will make any
The appliance is to be installed only by an authorized person (in Massachusetts this must be
future servicing difficult. Fisher & Paykel will not be liable for costs associated with releasing
a Massachusetts licensed gas fitter).
such products, nor for damage incurred as a result.
This product is supplied with an additional label containing the model and serial numbers. It
Download from Www.Somanuals.com. All Manuals Search And Download.
may be affixed to the underside of the product, the inside of a cupboard or to the User Guide.
PREPARING THE CUTOUT
PAGE 3 OF 6
GC36
GC901 / GC901M
Minimum horizontal distances from side and back of
appliance to adjacent vertical combustible walls (extending
Minimum horizontal distances from side and back of
appliance to adjacent vertical combustible walls
a minimum of 18" (C) from above the top panel) must be
(extending a minimum of 18" (C) from above the top panel)
must be 4" from the left side wall, 1" from the right side
wall and 1 1 2" from rear wall.
/
1
/
/
1
1
4" from the left side wall, 1" from the right side wall and
4" from rear wall.
1
Minimum horizontal distance from front edge of counter
Minimum horizontal distance from front edge of counter
to front side of appliance 2 1 2" (E). Where this reduces
/
1
/
to front side of appliance 1 4" (E). Where this reduces the
distance between the back edge of the appliance and the
the distance between the back edge of the appliance and
the adjacent wall to less than 1 1 2" (F), this wall must be
/
B
1
/
adjacent wall to less than 1 4" (F), this wall must be of
D
non combustible material.
C
of non combustible material.
Minimum clearance from combustible surface centered
above cooking surface 30" (A).
Minimum clearance from combustible surface centered
above cooking surface 30" (A).
A
F
Minimum horizontal distance between overhead cabinets
installed on either side of this appliance 36" (D).
Maximum depth of overhead cupboards, 13" (B).
These distances shall be from the outermost edge of the
top panel.
Minimum horizontal distance between overhead cabinets
installed on either side of this appliance 36" (D).
Maximum depth of overhead cupboards, 13" (B).
These distances shall be from the outermost edge of the
top panel.
E
Do use easy-to-clean finishes for the wall surfaces
surrounding the cooktop to aid removal of any cooking
stains resulting from use of the cooktop.
Do use easy-to-clean finishes for the wall surfaces
surrounding the cooktop to aid removal of any cooking
stains resulting from use of the cooktop.
Download from Www.Somanuals.com. All Manuals Search And Download.
CHECKING THE GAS TYPE
PAGE 4 OF 6
GC36
GC901 / GC901M
Burners
NG Orifice NG
LP Orifice
(mm)
LP
Burners
NG Orifice NG
LP Orifice
(mm)
LP
(mm)
BTU (MJ/h)@
BTU (MJ/h)@
(mm)
BTU (MJ/h)@
BTU (MJ/h)@
0.15psi (4”H 0)
0.41psi (11”H 0)
0.15psi (4”H 0)
0.41psi (11”H 0)
2
2
2
2
RH Rear
LH Rear
1.3mm
1.3mm
8,000 (8.4 MJ/h)
8,000 (8.4 MJ/h)
3,500 (3.47 MJ/h)
0.8mm
0.8mm
0.55mm
8,000 (8.4 MJ/h)
8,000 (8.4 MJ/h)
4,000 (4.2 MJ/h)
13,000 (13.7 MJ/h)
9,500 (10.0 MJ/h)
RH Rear
LH Rear
1.3mm
1.1mm
8,000 (8.4 MJ/h)
5,800 (6.1 MJ/h)
3,000 (3.2 MJ/h)
8,000 (8.4 MJ/h)
0.8mm
0.7mm
0.55mm
0.8mm
8,200 (8.7 MJ/h)
5,700 (6.0 MJ/h)
3,500 (3.7 MJ/h)
8,200 (8.7 MJ/h)
13,000 (13.7 MJ/h)
19,000 (20 MJ/h)
RH Front Simmer 0.85mm
RH Front Simmer 0.85mm
LH Front Wok
Center
1.75mm
1.45mm
13,000 (13.7 MJ/h) 1.05mm
9,500 (10 MJ/h) 0.85mm
LH Front
1.3mm
Center (GC901)
Center (GC901M)
1.75mm
2.15mm
14,000 (14.8 MJ/h) 1.05mm
20,000 (21.1 MJ/h) 1.22mm
GAS SUPPLY CONNECTION
A manual valve must be installed in an accessible location in the gas line external to the
appliance for the purpose of turning on or shutting off gas to the appliance. (In Massachusetts
such shutoff devices should be approved by the Board of State Examiners of Plumbers & Gas Fitters).
This appliance can be used with either LP gas or Natural gas. It is shipped from the
factory adjusted for use with Natural gas.
Instructions for converting the regulator between NG and LP
1. Unscrew the cap from the regulator.
2. Check the orientation of the plastic conversion plug, and if necessary, unscrew, turn over
and screw back in (wide section away from cap for LP and against cap for NG - see
diagram below for appropriate orientation.
For use with a gas pressure regulator. The regulator supplied can be set for either LP gas or
3. Replace regulator cap.
Natural gas and must be used with this appliance. It has a 1 2" NPT thread.
4. Test gas pressure (test point provision on side of regulator). When converting the regulator
for different settings, the function of the regulator must be checked at a pressure at least
1" WC (0.036 p.s.i.) above the specified manifold pressure.
/
Gas connection to the product must use the elbow supplied (it has a 1 2" NPT external thread).
/
Ensure the blue washer (supplied) is located between the elbow and the product
inlet. Failure to use this will cause the product to leak.
(Note: this diagram is of GC36 but is
similar for GC901 and GC901M).
NG
LP
Blue Washer
Download from Www.Somanuals.com. All Manuals Search And Download.
TESTING AND SETTING
PAGE 5 OF 6
After installing the gas supply and making all connections check thoroughly for possible leaks. Turn all control knobs on unit to "off" position. Open the valve on the gas supply. Using a leak
detection fluid (e.g. Rocol leak detection spray) check each gas connection one at a time by brushing the solution over the connection. The presence of bubbles will indicate a leak. Tighten the
fitting and recheck for leaks.
Leak testing of the appliance shall be conducted according to the manufacturer's instructions.
Turn on burner valve and light each burner. Check for a clear blue flame without yellow tipping. If burners show any abnormalities, check that they are located properly and in line with the
injector orifice.
The appliance and it's individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system in excess of 1 2 p.s.i. (3.5kPa).
/
The appliance must be isolated from the gas supply piping system by closing it's individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures at
or less than 1 2 p.s.i.(3.5kPa).
/
Maximum inlet gas supply pressure 4" W.P. Natural Gas, 11" W.P. LP gas.
Minimum gas supply pressure for regulator testing 5" W.P. Natural Gas, 12" W.P. LP gas.
CONVERSION TO DIFFERENT GAS TYPE
Burners can be used with all types of gas, provided that the orifices appropriate for the gas
delivered are installed.
The label supplied with the orifices can be placed over the existing gas label to indicate the change.
High altitude orifices are available from Fisher & Paykel USA (see address).
You will need a 9 32" (7mm) socket (and a 13 32" (10mm) socket for the GC901M).
/
/
To change the orifices:
1. Turn off the mains supply.
2. Ensure all gas valves are turned off.
GC36
NG Kit Part No. 530463
LP Kit Part No. 530464
3. Remove all grates and burner heads.
4. Pull off knobs.
GC901/M NG Kit Part No. 531566
5. Remove the two screws securing each burner (three on the wok burner).
6. Partially lift the hob and unplug the electrode on the simmer burner
(CAUTION: the edge can be sharp).
LP Kit Part No. 531567
7. Unscrew the orifices and replace them with the correct ones.
(Size numbers are stamped on the side e.g. 70 = 0.70mm).
8. Set the brass venturi on the wok burner to a distance of 3
”
/
5
(15mm) as indicated.
9. To replace the hob, repeat steps 4-6 in reverse.
Changing the orifice
(
Note: this diagram is of GC901 but is similar for GC36).
Download from Www.Somanuals.com. All Manuals Search And Download.
MINIMUM SETTING OR TURNDOWN
PAGE 6 OF 6
This has been set at the factory for NG but can be checked after the correct pressure has been
reached. To adjust for minimum setting, if needed. You will need a Ø 7 " x 1 3 4" (Ø2.5 x 45mm)
/
/
64
screwdriver. (A suitable screwdriver is available as Fisher & Paykel spare part. FB200467).
1. Ignite the burner and set the knob to its minimum position.
2. Remove the knobs.
3. Rotate the turn down screw (down the hole in the spindle) while holding the shaft.
Rotate slowly until a minimum regular flame is achieved. (The flame will diminish when
the screw is turned clockwise and increase when turned counter clockwise).
4. When the setting is right check regulation by quickly rotating the knob from the
maximum to the minimum delivery position. The flame must not go out and the
autoreignition should not click. Replace the knob.
Minimum setting adjustment
(Note: this diagram is of GC901 but is similar for GC36).
See the Product Installation Checklist attached to the product.
A Service Summary is attached to the underside of the product.
For replacement parts or if further help is needed concerning this appliance call:
TOLL FREE 1 888 9 FNP USA (1 888 936 7872)
or write to:
Fisher & Paykel Appliances Inc.
27 Hubble, Irvine
CA 92618
or contact us through our web site,
Download from Www.Somanuals.com. All Manuals Search And Download.
|