Product Specification
RoHS-6 Compliant
10Gb/s 1310nm Single Mode XENPAK Transponder
FTLX1461E2
PRODUCT FEATURES
Hot pluggable XENPAK MSA
form factor
Total power consumption: 3.5 W
maximum
RoHS-6 compliant (lead-free)
Temperature range 0°C to 70°C
Transmission distance of 10km
Uncooled directly modulated
1310nm Distributed Feedback (DFB)
laser
SC connector, single mode fiber
Full duplex transmission mode
Digital Optics Monitoring (DOM)
Power supply: +5.0 V, +3.3 V,
Adaptable Power Supply (APS:
+1.2 V)
XAUI electrical interface
- 4 x 3.125 Gb/s Ethernet
Management and control via MDIO
2-wire bus
APPLICATIONS
10GBASE-LR 10G Ethernet
70-pin connector
Separated signal/chassis ground
PRODUCT SELECTION
FTLX1461E2
© Finisar Corporation – October 2008
Rev B
Page 1
Download from Www.Somanuals.com. All Manuals Search And Download.
FTLX1461E2 Product Specification – October 2008
Receive Functions
Reserved
Reserved
RX LANE 0+
RX LANE 0–
O
O
O
O
38
39
41
42
Reserved For Future Use
Reserved For Future Use
Module XAUI Output Lane 0+
Module XAUI Output Lane 0–
AC-coupled,
Internally biased
differential
XAUI
RX LANE 1+
RX LANE 1–
RX LANE 2+
RX LANE 2–
RX LANE 3+
RX LANE 3–
DC Power
O
O
O
O
O
O
44
45
47
48
50
51
Module XAUI Output Lane 1+
Module XAUI Output Lane 1–
Module XAUI Output Lane 2+
Module XAUI Output Lane 2–
Module XAUI Output Lane 3+
Module XAUI Output Lane 3–
GND
0 V DC
1, 2, 3, 33, 34,
35, 36, 37, 40,
43, 46, 49, 52,
53, 54, 57, 60,
63, 66, 69, 70
7, 8, 28, 29
27
Ground connection for signal ground
on the module
APS
APS SENSE
+1.2 V
+1.2 V
Input from Adaptive Power Supply
APS Sense Output. Connected to the
APS input inside transponder.
Feedback input from APS.
Connected to GND through a 1180Ω
resistor inside the transponder.
DC Power Input, +3.3 V DC,
Nominal
APS SET
25
3.3 V
5.0 V
+3.3 V DC
+5.0 V DC
5, 6, 30, 31
4, 32
DC Power Input, +5.0 V DC,
Nominal
Reserved
Reserved
26
13
Reserved for APD.
Reserved.
© Finisar Corporation – October 2008
Rev B
Page 3
Download from Www.Somanuals.com. All Manuals Search And Download.
FTLX1461E2 Product Specification – October 2008
Electrical Pad Layout
Fig 1-XENPAK Transponder Electrical Pad Layout
II. Absolute Maximum Ratings
Limit Values
Parameter
Storage Ambient Temperature1)
Operating Case Temperature1)
Supply Voltage +5.0 V
Symbol
TS
Unit
°C
°C
V
min.
-40
0
max.
85
70
TC
V5
0
6
Supply Voltage +3.3 V
V3
0
4
V
Supply Voltage APS
Vaps
STd
RxP max
0
1.5
500
1.5
V
V
dBm
Static Discharge Voltage, All Pins2)
Average Receive Optical Power
Notes:
1) Non-condensing.
2) HBM
Exceeding any one of these values may permanently destroy the device.
© Finisar Corporation – October 2008
Rev B
Page 4
Download from Www.Somanuals.com. All Manuals Search And Download.
FTLX1461E2 Product Specification – October 2008
III. Electrical Characteristics
Recommended Operating Conditions
Values
typ.
Parameter
Operating Case Temperature1)
Transponder Total Power
Consumption
Symbol
Unit
°C
min.
0
max.
70
TC
P
3.5
W
Supply Voltage +5.0 V
Supply Current +5.0 V
Supply Voltage +3.3 V
Supply Current +3.3 V
Supply Voltage APS
Supply Current APS
VCC5
ICC5
VCC3
ICC3
VCC aps
ICC aps
4.75
3.14
5.0
3.3
1.2
5.25
300
3.47
300
1.248
1000
V
mA
V
mA
V
1.152
mA
1) Worst case thermal location, see Figure 2.
See also Environmental Performance.
Electrical DC Characteristics
(VCC5 = 4.75 V to 5.25 V, VCC3 = 3.14 V to 3.47 V, VCC aps = 1.152 V to 1.248 V, TC = 0°C to 70°C)
Values
Parameter
Symbol
Unit
min.
typ.
max.
1.2 V CMOS (1.8 V CMOS Compatible1)) I/O DC Characteristics
(PRTAD; LASI; RESET; TX_ONOFF)
External Pull-up Resistor for Open Drain
Rpullup
Voh
Vol
10
1
22
kΩ
V
V
Output High Voltage2)
Output Low Voltage2)
Input High Voltage
0.15
1.5
Vih
0.84
V
Input Low Voltage
Vil
Ipd
0.36
120
V
µA
Input Pull-down Current3)
20
XAUI I/O DC Characteristics (TXLANE[0..3]; RXLANE[0..3])
Differential Input Amplitude (pk-pk)4)
Vin_xaui
Vout_xaui
200
800
2500
1600
mV
mV
Differential Output Amplitude (pk-pk)4)
MDIO I/O DC Characteristics (MDIO; MDC)
Output Low Voltage5)
Output Low Current
Input High Voltage
Input Low Voltage
Pull-up Supply Voltage
Input Capacitance
VOL
IOL
VIH
VIL
VPU
CIN
CLOAD
RLOAD
–0.3
0.2
4
1.5
0.36
1.248
10
V
mA
V
V
V
pF
pF
Ω
0.84
–0.3
1.152
1.2
Load Capacitance
External Pull-up Resistance
470
200
1)
For 1.8 V CMOS Voh = 1.65 V min., Vol = 0.15 V max., Vih = 1.17 V min., Vil = 0.63 V max.
2)
3)
4)
5)
Rpull-up = 10 kΩ to 1.8 V.
Vin = 1.2 V.
AC coupled.
IOL = 100 µA.
© Finisar Corporation – October 2008
Rev B
Page 5
Download from Www.Somanuals.com. All Manuals Search And Download.
FTLX1461E2 Product Specification – October 2008
Electrical AC Characteristics
(VCC5 = 4.75 V to 5.25 V, VCC3 = 3.14 V to 3.47 V, VCC aps = 1.152 V to 1.248 V, TC = 0°C to 70°C)
Values
Parameter
Symbol
Unit
min.
typ.
max.
XAUI Input AC Characteristics (TXLANE[0..3])
Baud Rate
RXAUIIN
Gbit/s
Ethernet
3.125
100
Baud Rate Tolerance
Differential Input Impedance
Differential Return Loss1)
Input Differential Skew2)
Jitter Amplitude Tolerance3)
RTOLXAUI
ZINXAUI
|S11|
tSKEWIN
JXAUITOL
–100
80
10
100
120
ppm
Ω
dB
75
ps
0.65
UIp-p
XAUI Output AC Characteristics (RXLANE[0..3])
Baud Rate
Ethernet
Baud Rate Variation
RXAUIOUT
Gbit/s
ppm
3.125
RXAUIVAR
–100
100
XAUI Eye Mask (far-end)
Output Differential Skew
Output Differential Impedance
Differential Output Return Loss1)
Total Jitter4)
According to IEEE 802.3ae
15
tSKEWOUT
ZOUTXAUI
|S22|
TJXAUI
DJXAUI
ps
Ω
dB
UI
UI
80
10
100
120
0.35
0.37
Deterministic Jitter4)
Power-On Reset AC Characteristics
Power-On Reset and TX_ONOFF
Characteristics
According to XENPAK MSA Issue 3.0, 2002-9-18
MDIO I/O AC Characteristics (MDIO; MDC)
MDIO Data Hold Time
MDIO Data Setup Time
Delay from MDC Rising Edge to
MDIO Data Change
tHOLD
tSU
tDELAY
10
10
ns
ns
ns
300
MDC Clock Rate
ƒMAX
2.5
MHz
1)
100 MHz to 2.5 GHz.
At crossing point.
Per IEEE Std 802.3ae.
At near-end, No pre-equalization, 1 UI = 320 ps.
2)
3)
4)
© Finisar Corporation – October 2008
Rev B
Page 6
Download from Www.Somanuals.com. All Manuals Search And Download.
FTLX1461E2 Product Specification – October 2008
IV. Optical Characteristics
(VCC5 = 4.75 V to 5.25 V, VCC3 = 3.14 V to 3.47 V, VCC aps = 1.152 V to 1.248 V, TC = 0°C to 70°C)
Values
Parameter
Symbol
Unit
min.
typ.
max.
Transmitter
Launch Power in OMA minus TDP
Average Launch Power
Center Wavelength Range
Spectral Width(-20 dB)
PO-OMA
PO-Avg
λC-Tx
σI
–5.2
–8.2
1290
dBm
dBm
nm
0.5
1330
0.6
nm
Side Mode Suppression Ratio
Extinction Ratio
SMSR
ER
30
3.5
dB
dB
Relative Intensity Noise12OMA
Optical Modulation Aplitude (OMA)
Transmitter and Dispersion Penalty
Average Launch Power of OFF
Transmitter
RIN
–128
dB/Hz
dBm
dB
OMA
TDP
PO-OFF
–5.2
3.2
–30
dBm
Optical Return Loss Tolerance
Transmitter Reflectance
Eye Mask Definition
ORLT
REFTX
12
–12
dB
dB
According to IEEE 802.3ae
Receiver
Stressed Receiver Sensitivity in OMA
Rx Sensitivity in OMA1)
Average Receiver Power1)
Receiver Damage Power
Signal Detect Assert Level
Signal Detect Hysteresis
Receiver Reflectance
PIN-S
PIN-O
PIN
PIN-dmg
PLOSa
PLOSh
REFRX
FC
–10.3
–12.6
0.5
1.5
–13
dBm
dBm
dBm
dBm
dBm
dB
-14.4
1
–12
12.3
dB
GHz
Receive Electrical 3dB Upper Cutoff
Frequency
Center Wavelength Range
Stressed Signal Calibration
Vertical Eye Closure Penalty
Stressed Eye Jitter
λC-RX
1260
1355
nm
2.2
0.3
dB
UIpp
1)
Average Receiver Power (min), which is defined for an ideal input signal, is informative only.
V. General Specifications
Optical Interface Standard Specifications
Differential Group Delay
Standard
B1.1 SMF
B1.3 SMF
Maximum (ps)
Operating Range 1) (meters)
2 to 10,000
10
10
2 to 10,000
Notes:
1) Operating range as defined by IEEE standards. Longer reach possible depending upon link implementation.
© Finisar Corporation – October 2008
Rev B
Page 7
Download from Www.Somanuals.com. All Manuals Search And Download.
FTLX1461E2 Product Specification – October 2008
Environmental Performance
Operating case temperature:
Operating humidity:
0°C to +70°C
0% -95% RH non-condensing
Fibers and Connectors
The transponder has SC receptacles for both Tx and Rx. The transponder is designed for single
mode SC cables, 0° polished endface (PC).
70-pin Connector
The module interface connector is a 70-pin, printed circuit board edge connection with a 0.5 mm
pitch. The appropriate mating connector for the customer PCB is a 70-pin SMT, dual row, right
angled, edge connector, 0.5 mm pitch (Tyco Electronics part number 1367337-1, Molex part
number 74441-0003 or equivalent).
Rail Requirement
The XENPAK rail system required to mount the XENPAK module is fully defined by the MSA.
Aqueous Wash
Finisar XENPAK transponders are neither solderable nor aqueous washable and are not
intended for these processes.
VI.
Regulatory Compliance
Feature
Standard
Comments
ESD:
EIA/JESD22-A114-B
(MIL-STD 883D
Method 3015.7)
EN 61000-4-2
Class 1a (> 500 V)
Electrostatic Discharge to the
Electrical Pins (HBM)
Immunity:
Against Electrostatic Discharge
(ESD) to the Module Receptacle
Discharges ranging from ±2 kV to ±25 kV to
the front end / faceplate / receptacle cause no
damage to module (under recommended
conditions).
IEC 61000-4-2
Immunity:
Against Radio Frequency
Electromagnetic Field
EN 61000-4-3
IEC 61000-4-3
With a field strength of 10 V/m, noise
frequency ranges from 10 MHz to 2 GHz. No
effect on module performance between the
specification limits.
Emission:
Electromagnetic Interference
(EMI)
FCC 47 CFR
Part 15, Class B
EN 55022 Class B
CISPR 22
Noise frequency range:
30 MHz to 40 GHz
Radiated emission does not exceed specified
limits when measured inside a shielding
enclosure with MSA conform cutout.
© Finisar Corporation – October 2008
Rev B
Page 8
Download from Www.Somanuals.com. All Manuals Search And Download.
FTLX1461E2 Product Specification – October 2008
Eye Safety
Finisar FTLX1461E2 transponders are Class 1 Laser Products. They are certified per the
following standards:
Feature
Agency
FDA/CDRH
TÜV
Standard
Certificate
Number
9210176-104
Laser Eye
Safety
Laser Eye
Safety
CDRH 21 CFR 1040 and Laser Notice 50
EN 60825-1: 1994+A11:1996+A2:2001
IEC 60825-1: 1993+A1:1997+A2:2001
IEC 60825-2: 2000, Edition 2
EN 60950
R 72082131
Electrical
Safety
Electrical
Safety
TÜV
R 72082131
1439230
UL/CSA
CLASS 3862.07
CLASS 3862.87
Copies of the referenced certificates are available at Finisar Corporation upon request.
VII. DOM Parameters
Values
Parameter
Transponder Temperature Monitor Accuracy1)
Laser Bias Current Monitor Accuracy2)
Transmit Power Monitor Accuracy3)
Receive Power Monitor Accuracy3)
Unit
°C
%
dB
dB
min.
-5
-10
-3
typ.
max.
+5
+10
+3
-3
+3
1)
0 to 70°C case temperature.
0 to 12.5 mA.
-8.2 dBm to +0.5 dBm.
2)
3)
VIII. Mechanical Characteristics
Parameter
Symbol
Values
Unit
min.
typ.
200
40
max.
Module Retention Force (latch strength)
Module Insertion Force
Module Extraction Force (with kick-out)
Module Extraction Force (without kick-out)
FRET
FIN
FEXT-K
FEXT
N
N
N
N
16
25
© Finisar Corporation – October 2008
Rev B
Page 9
Download from Www.Somanuals.com. All Manuals Search And Download.
FTLX1461E2 Product Specification – October 2008
Package Outline
Figure 2-XENPAK Mechanical Dimensions
IX.
References
The following references are provided for informational purposes only. The parameters and
operational behavior outlined in this specification describe the complete functionality of the 10G
Transponder. Contact Finisar for any items concerning the operational characteristics of this
device.
IEEE Std 802.3ae-2002 clause 52, 10GBASE-LR
XENPAK MSA Issue 3.0
X.
For More Information
Finisar Corporation
1389 Moffett Park Drive
Sunnyvale, CA 94089-1133
Tel. 1-408-548-1000
Fax 1-408-541-6138
© Finisar Corporation – October 2008
Rev B
Page 10
Download from Www.Somanuals.com. All Manuals Search And Download.
|