FieldServer Server FS RA CLX FIR User Manual

A Sierra Monitor Company  
SlotServer Start-Up Guide  
APPLICABILITY & EFFECTIVITY  
This manual provides instructions for the following FieldServer products:  
Description  
FS-RA-CLX-BAS  
FS-RA-CLX-FIR  
FS-RA-CLX-PRO  
The instructions are effective for the above as of November 2009  
Kernel Version:  
Document Revision:  
5.15  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
SlotServer Start-Up Guide  
Page 3 of 14  
1
EQUIPMENT SET-UP  
1.1 SUPPLIED EQUIPMENT  
USB Flash Drive loaded with:  
SlotServer Start-up Guide  
SlotServer Configuration Manual  
FieldServer Utilities Manual  
All FieldServer Driver Supplements  
Support Utilities  
Any additional folders related to special files configured for a specific FieldServer  
Additional components as required - See Driver Manual Supplement for details  
Accessories:  
2-way combi-comb connector for LonWorks port  
7-ft Cat5 cable with RJ45 connectors at both ends (Part # FS-8915-10)  
1.2 THIRD PARTY COMPONENTS (NOT SUPPLIED BY FIELDSERVER TECHNOLOGIES)  
The following components will need to be procured as a minimum for achieving ControlLogix integration. Ensure  
that these are available before commencing with commissioning  
Part #  
Description  
AB1756-Ax  
AB1756-l55/l61  
AB1756-PA7x  
ControlLogix Rack  
ControlLogix CPU  
ControlLogix PSU  
9324-RLD300ENE RSLOGIX 5000  
1.3 MOUNTING  
The SlotServer plugs directly into the AB1756 ControlLogix rack. Take note of the slot number used for the  
SlotServer as this will be needed when configuring the I/O in the RSLogix software.  
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com  
Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: [email protected]  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
SlotServer Start-Up Guide  
Page 4 of 14  
1.4 SLOTSERVER PORTS AND DISPLAYS  
Note that there are several hardware ports available on the SlotServer card, but that this SlotServer model only  
makes use of a select few. The ports and displays of interest are as shown in the diagram below:  
Scrolling display shows card messages  
Card Status Indicators show general card status  
Service Pin for LonWorks Commissioning  
Communications Status LED’s show status of  
communications and card software.  
TP/FT10 LonWorks Connection.  
This two wire  
connection is polarity insensitive and can be multi-  
dropped into a LonWorks Network.  
Ethernet Port. The Ethernet port can be used with  
standard Ethernet cables for configuration and  
troubleshooting, as well as for Protocols that require an  
Ethernet connection  
RS-485 Port. This is a standard 2-wire RS-485 port.  
Specify as R1 in the configuration.  
A label has been provided on the inside of the  
cover door for the User to document important or  
useful configuration parameters used. In  
particular, special provision has been made to  
document the Ethernet port IP parameters, as well  
as the LonWorks DSN (Domain/Subnet/Node)  
allocated by the Network Manager. These fields  
are there to be utilized at the User’s discretion.  
Figure 1: Diagram of SlotServer showing ports and displays  
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com  
Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: [email protected]  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SlotServer Start-Up Guide  
Page 5 of 14  
1.5 TECHNICAL SPECIFICATIONS  
The following table presents the relevant technical specifications.  
Slot width  
1
BackPlane Current Load  
Operating Temperature  
Storage Temperature  
Humidity  
Allen Bradley Platform:  
LonWorks Connection type:  
Ethernet port  
0.6A  
0-60°C (32-140°F)  
-40 - 85°C (-40 - 185°F)  
5-95% (Non-Condensing)  
ControlLogix 1756 Rack  
TP/FT-10  
10/100 MB/sec.  
2-wire, half duplex.  
UL 60950-1:2003  
CAN/CSA-C22.2 No.60950-1-03  
RS-485 port  
Approvals  
Table 1: Product Specifications  
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com  
Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: [email protected]  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SlotServer Start-Up Guide  
Page 6 of 14  
2
INSTALLATION  
The SlotServer plugs directly into the AB1756 ControlLogix rack. Take note of the slot number used for the  
SlotServer as this will be needed when configuring the I/O in the RSLogix software.  
2.1 POWER UP THE DEVICE  
Apply power to the device. Refer to the panel to ensure that the SlotServer has powered up successfully. The  
diagram in Section 1.4 indicates the location of each of these items on the SlotServer panel.  
Scrolling Display  
This will Display an OK status when the SlotServer has powered up successfully.  
Card Status  
The Comm and OK lights will indicate green when the SlotServer has powered up  
Indicators:  
successfully. The Sys indicator will indicate green if the external nodes are all  
communicating properly; and red otherwise.  
2.2 INSTALL AND RUN THE UTILITY SOFTWARE  
Plug the supplied USB flash drive into the USB port on a PC/laptop.  
Open Index.html to get the menu of options  
Run the Install option and follow the installation instructions.  
Once installed, the FieldServer Utilities can be located in the Windows Start menu and as a desktop icon.  
2.3 CONNECT THE PC TO THE SLOTSERVER OVER THE ETHERNET PORT.  
If connecting through a hub/switch, use the supplied Cat5 UTP Ethernet cable to connect between the  
Ethernet port of the SlotServer and the hub. Refer to Section 0 for more information.  
If it is necessary to connect the PC directly to the SlotServer, a cross-over cable is required (not supplied).  
Disable any wireless Ethernet adapters on the PC/Laptop,  
It is important that the PC/Laptop is on the same subnet as the SlotServer. The default IP address on the  
SlotServer Ethernet port is 192.168.2.X. Refer to the FieldServer Utilities Manual for information on how  
to change the SlotServer’s IP address.  
2.4 USING THE PING UTILITY TO IDENTIFY THE SLOTSERVER ON THE NETWORK  
Select Start|Programs|FieldServer Utilities, browse to the Ping Utility and select it. The display should  
show  
SlotServer Name  
IP Address (192.168.2.X)  
SlotServer Version  
If necessary, refer to Appendix A for troubleshooting tips.  
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com  
Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: [email protected]  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
SlotServer Start-Up Guide  
Page 7 of 14  
2.5 CONNECT USING “REMOTE USER INTERFACE” (RUINET)  
All configuration file transfers and system diagnostics are executed via the RUI or “Remote User Interface” which is  
installed with the Utility software. Refer to the FieldServer Utilities manual for further information.  
Browse to the Remote User Interface icon in the Start menu directory and click on it.  
The RUI menu screen should appear.  
If necessary, refer to Appendix A for troubleshooting tips.  
2.6 UPLOAD THE DEFAULT CONFIGURATION  
The configuration of the SlotServer is provided to the FieldServer’s operating system via a comma-delimited file  
called “CONFIG.CSV”. If ordered with the SlotServer, the custom configuration is installed; (Reference  
documentation FS-8790-XX). If a custom configuration is not purchased, a template config.csv is shipped on the  
SlotServer. Refer to the SlotServer Configuration Manual and the Driver Manual(s) provided with the SlotServer  
for further information on configuration files.  
In the main menu of the Remote User Interface screen, type “U” to upload the configuration. Then type  
“U” again. The Remote User Interface Utility will fetch the default configuration and put it into the  
Configuration File folder (Start|Programs|FieldServerUtilities|Configuration File folder).  
2.7 CHANGE THE CONFIGURATION FILE TO MEET THE APPLICATION  
FieldServer Technologies offers training on this topic as well as a configuration service to complete this portion of  
the work. See www.fieldserver.com for specific details.  
Refer to the FieldServer Configuration Manual for instruction on writing a FieldServer configuration.  
Refer to the SlotServer Configuration Manual for assistance on managing the Logix driver Parameters  
Refer to the desired protocol Driver Supplement for assistance on managing the protocol parameters.  
2.8 DOWNLOAD THE UPDATED CONFIGURATION FILE  
Before attempting to send files to the SlotServer, ensure that the files are in the configuration file folder. Refer to  
the FieldServer Utilities manual for further information.  
From the main menu, type "D" to access the “download” menu,  
Type "L" (for local filename) to specify the name and extension of the file to be sent to the SlotServer. Hit  
<Enter> when done.  
The Remote User Interface Utility will automatically select config.csv for download of csv files. On rare  
occasions where other files need to be downloaded to the SlotServer type “O” for other files, then type  
R” to specify the remote filename needed on the SlotServer.  
When satisfied that the correct file names are specified, Type "D" to download the file to the SlotServer.  
The Remote User Interface Utility will display a menu showing download progress.  
Note: the Remote User Interface Utility will indicate when download is complete. DO NOT reset the SlotServer  
before this message displays, as this could corrupt the SlotServer.  
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com  
Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: [email protected]  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
SlotServer Start-Up Guide  
Page 8 of 14  
Once download is complete, hit <Esc> to get back to the main menu and use the "!" option (or simply  
cycle power to the SlotServer) to put the new file into operation. Note that it is possible to do multiple  
downloads to the SlotServer before resetting it.  
Firmware created by FieldServer Technologies can be downloaded from the configuration file by simply  
typing “F” from the download menu. Note that FieldServer usually supplies firmware upgrades as an  
install.zip, for which a separate procedure is used, (See ENote 037 on the USB flash drive in a folder called  
Library.  
2.9 TEST AND COMMISSION THE SLOTSERVER  
Connect the SlotServer to the third party devices, and test the application.  
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com  
Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: [email protected]  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SlotServer Start-Up Guide  
Page 9 of 14  
Appendix A. Useful Features  
Refer to the Configuration Manual for useful configuration features.  
The unit may be removed under power for convenient swapping of modules.  
Appendix A.1. LED Functions  
Service Pin  
The LonWorks Service pin can be used for commissioning the SlotServer  
into a LonWorks network.  
LonSvc  
Conf Err  
Com Err  
Run  
Node Off  
Sys Err  
LonWorks Activity can be determined using this LED as follows:  
LON LED Activity  
Explicit Implicit Not  
Implicit –  
Commissioned  
Off  
Commissioned  
Off  
Flashing  
Rx  
Tx  
Figure 3: Diagram of SlotServer showing ports and displays  
LED  
Description  
When the SlotServer is powered up, this light will start flashing after  
approximately 2 minutes. If this light does not flash, it is an indication that the  
firmware is not running, and that the SlotServer will not be operating.  
This LED indicates LonWorks activity. Refer to Figure 3.  
This light indicates that a device bound to the SlotServer on the LonWorks network  
is not communicating. Use the LonWorks Network Manager to troubleshoot the  
problem.  
Run  
LonSvc  
NodeOff  
This light indicates an error in the configuration of the card. Since this model is  
shipped pre-configured, this light should never come on unless the card  
configuration is tampered with  
This light indicates that an unexpected operation state occurred. The light can be  
reset by cycling power to the card. If the error re-occurs persistently, then contact  
FieldServer Technical support for assistance with troubleshooting after setting up  
the trade port as shown in Appendix A.  
Conf Err  
Sys Err  
This light indicates that a communication error occurred. Use the LonWorks  
Network Manager to troubleshoot the problem, or refer to the SlotServer  
configuration Manual.  
Com Err  
These lights are related to the RS-485 serial ports provided on the SlotServer. The  
Rx (Receive) light will flash red if the FieldServer is receiving data. The Tx  
(Transmit) light will flash red if the FieldServer is sending data. (Note that due to  
the nature of 2-wire RS-485 the Rx light will flash every time the Tx light flashes  
too). The frequency of the flashing is directly related to the frequency of data  
transfer.  
RS-485  
(R1)  
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com  
Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: [email protected]  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
SlotServer Start-Up Guide  
Page 10 of 14  
Ethernet Lights  
10/100  
These lights are related to the Ethernet network ports provided on the SlotServer.  
The 10/100 light will be green if the physical connection to the network hub is  
running at 100 MBits/s. If the light is off, the connection is running at 10 MBits/s.  
The Act (Activity) light will indicate activity on the network. The frequency of  
flashing is directly related to the network activity. It does not necessarily mean  
data is being received by the FieldServer.  
Act  
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com  
Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: [email protected]  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SlotServer Start-Up Guide  
Page 11 of 14  
Appendix B. Troubleshooting  
Appendix B.1. Things to check when communications fail.  
Check for loose cabling on the third party network  
Verify that the correct program is loaded to the CPU  
Verify that the correct data types for the tags have been used.  
Appendix B.2. Timeout Errors on SlotServer  
The following remedial action is suggested if timeout errors are experienced:  
The PLC is not set to RUN mode - it may still be in PRG mode. Resolve by putting the PLC into RUN mode.  
The IO image connection has not been established successfully. The F screen should show some error  
messages also. Refer to the Slotserver Configuration Manual, and insert the correct size and RPI values  
when adding the SlotServer in RSLogix5000.  
Appendix B.3. Data Transfer  
It is important that the PLC is set to Run data is only transferred on Run.  
The SlotServer’s Logix connection will transfer data to the PLC regardless of the Node status of the Client  
Nodes. The Logix connection will not be broken if a Client Node goes offline. Node status can be  
confirmed by checking the Node Status bits.  
Appendix B.4. ASIC Error on Soft Restart  
If the SlotServer is restarted using Ruinet (!) while the PLC is running, the SlotServer will try to reset the ASIC chip.  
When it finds it is unable to do this it will produce the following Error message and continue to cycle power to the  
SlotServer creating an endless loop.  
Under these circumstances it is recommended that the PLC is stopped before the SlotServer is restarted.  
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com  
Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: [email protected]  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
SlotServer Start-Up Guide  
Page 12 of 14  
Appendix B.5. Technical Support  
Before contacting Technical support to report an issue, go to Start|Programs|FieldServer utilities|Tools and  
browse to Serial Capture. Take a log (See ENotes 26 and 58 in the folder called Library on the USB Flash Drive).  
Send this log together with the configuration file to [email protected] for evaluation.  
Note that while all necessary documentation is shipped with the FieldServer on the USB flash drive, these  
documents are constantly being updated. Newer versions may be available on the web at www.fieldserver.com.  
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com  
Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: [email protected]  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SlotServer Start-Up Guide  
Page 13 of 14  
Appendix C. Vendor Information  
Appendix C.1. Installing SlotServer on a Remote Rack using CNB Cards 1  
Appendix C.1.1.  
Hardware and Software requirements  
Two 1756 racks, one containing the CPU and the other the SlotServer  
Two Controlnet CNB cards with connection cables to connect the racks to one other  
RSlinx  
RSLogix  
RSNetworx  
SlotServer EDS file (Available on SlotServer CD, or call Technical Support)  
Appendix C.1.2.  
Setup  
Install the CPU and the first CNB card in the local rack.  
Install the second CNB card and the SlotServer in the remote rack.  
Connect the ControlNet Network  
Power up the racks  
Install the SlotServer EDS File using the RSLinx Hardware EDS Installation Tool.  
Make sure the SlotServer has a valid configuration loaded. The default configuration shipped with the  
SlotServer should suffice.  
Refer to the SlotServer Configuration Manual for further information.  
1 The principles for connecting other 1756 bridging cards to the SlotServer are similar.  
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com  
Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: [email protected]  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
SlotServer Start-Up Guide  
Page 14 of 14  
Appendix D. Limited Warranty  
FieldServer Technologies warrants its products to be free from defects in workmanship or material under normal  
use and service for two years after date of shipment. FieldServer Technologies will repair or replace without  
charge any equipment found to be defective during the warranty period. Final determination of the nature and  
responsibility for defective or damaged equipment will be made by FieldServer Technologies personnel.  
All warranties hereunder are contingent upon proper use in the application for which the product was intended  
and do not cover products which have been modified or repaired without FieldServer Technologies approval or  
which have been subjected to accident, improper maintenance, installation or application, or on which original  
identification marks have been removed or altered. This Limited Warranty also will not apply to interconnecting  
cables or wires, consumables or to any damage resulting from battery leakage.  
In all cases FieldServer Technology’s responsibility and liability under this warranty shall be limited to the cost of  
the equipment. The purchaser must obtain shipping instructions for the prepaid return of any item under this  
warranty provision and compliance with such instruction shall be a condition of this warranty.  
Except for the express warranty stated above, FieldServer Technologies disclaims all warranties with regard to the  
products sold hereunder including all implied warranties of merchantability and fitness and the express warranties  
stated herein are in lieu of all obligations or liabilities on the part of FieldServer Technologies for damages  
including, but not limited to, consequential damages arising out of/or in connection with the use or performance  
of the product.  
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com  
Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: [email protected]  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 

Earthquake Sound Car Speaker EQ8S8 User Manual
Earthquake Sound Speaker 846X User Manual
Electro Voice Portable Speaker SENTRY IVA User Manual
First Alert Home Security System FA148C User Manual
Foundry Networks Switch LS 624 User Manual
Frigidaire Microwave Oven 316495002 User Manual
Gateway Laptop 600YG2 User Manual
GBC Chipper 1236SE User Manual
GE Monogram Satellite Radio ZBD3500ZWW User Manual
GE MP3 Player EPM 3000P User Manual