Residential and OutdOOR WOOd buRning FiReplace
OWneR’s OpeRatiOn and installatiOn Manual
PFS
®
ICC-ES #ESR-2542
MOdels (V)s36 seRies
SAVE THIS BOOK
This book is valuable. In addition to instructing you
on how to install and maintain your appliance, it also
contains information that will enable you to obtain re-
placement parts or accessory items when needed. Keep
it with your other important papers.
Thisfireplaceisapprovedforuseasawoodburningfire-
place or for use with a vented gas log approved to ANS
Z21.60 or Z21.84 standards or for use with a vent-free
gaslogheaterapprovedtoANSZ21.11.2standard.AFMI
PRODUCTS, LLC hood must be installed when using a
vent-free log heater (see Accessories, page 16).
This wood burning fireplace complies with UL127-
CAN/ULS-S610-M87 standard as a FACTORY BUILT
APPLIANCE.
FOR CANADA: The authority having jurisdiction (such
as the municipal building department, fire department,
etc.) should be contacted before installation to deter-
mine the need to obtain a permit.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
Download from Www.Somanuals.com. All Manuals Search And Download.
speciFicatiOns
ELECTRICAL
OUTLET
1" AIRSPACE
TO COMBUSTIBLE
MATERIAL
RIGHT SIDE
GAS LINE
KNOCK OUTS
0" TO
TOP SPACERS
NO COMBUSTIBLE
MATERIAL ON FACE
8.125"
2.5"
7.092"
8.717"
11.217"
AIR KIT
KNOCK OUT
LEFT SIDE
GAS LINE
KNOCK OUTS
COMBUSTIBLE
WALL BOARD
3/4" AIR SPACE
BACK AND SIDES
10.435"
8.125"
2.5"
NOT LESS
THAN 12"
TO PERPENDICULAR
SIDEWALL
OUTSIDE AIR
(LEFT SIDE ONLY)
8.717"
14.437"
HEARTH EXTENSION
52" X 16"
8"
EACH SIDE
0" TO
BOTTOM
22"
29"
14.25"
21
12.5"
32.5"
0.625"
41"
ROUND TOP TERMINATION
1"
41.25"
SQUARE CHASE-TOP
TERMINATION
21"
37"
8"
35"
41"
1"
111026-01J
Download from Www.Somanuals.com. All Manuals Search And Download.
3
FiReplace installatiOn
SELECTING LOCATION
FRAMING
To determine the safest and most efficient 1. Frame opening for fireplace using the
location for the fireplace, you must take into
consideration the following guidelines:
dimensions shown in Figures 1 and 2.
2. If fireplace is to be installed directly on
carpeting, tile (other than ceramic) or any
combustible material other than wood
flooring, the fireplace must be installed
upon a metal or wood panel extending
the full width and depth of fireplace.
1. The location must allow for proper clear-
ances (see Figures 1 and 2).
2. Consider a location where the fireplace
will not be affected by drafts, air condition-
ing ducts, windows or doors.
3. Set fireplace directly in front of this open-
ing and slide unit back until nailing flanges
touch side framing.
3. A location that avoids the cutting of
joists or roof rafters will make installation
easier.
4. Check the level of the fireplace and shim
with sheet metal if necessary.
4. An outside air kit is available with this
fireplace (see Optional Outside Air Kit on
page 6).
5. Before securing fireplace to prepared
framing, the ember protector (provided)
must be placed between the hearth ex-
tension (not supplied) and under bottom
front edge of fireplace to protect against
glowing embers falling through. If fireplace
is to be installed on a raised platform, a Z-
type ember protector (not supplied) must
be fabricated to fit your required platform
height. The ember protector should ex-
tend under fireplace a minimum of 1 1/2".
The ember protector should be made of
galvanized sheet metal (28 gauge mini-
mum) to prevent corrosion.
MINIMUM CLEARANCE TO
COMBUSTIBLES
Back and sides of fireplace 3/4" minimum*
Floor**
0" minimum
Perpendicular wall to opening 12" minimum
Top spacers
0" minimum
Mantel clearances
see Mantels, page 5
Chimney outer pipe surface
* Not required at nailing flanges
1" minimum
** See step 2 of Framing
WARNING: Do not pack re-
quiredairspaceswithinsulation
or other materials.
6. Using screws or nails, secure fireplace to
framing through flanges located on sides
of fireplace.
Minimum/Maximum Chimney Height for
Residential Installation
The minimum height of the chimney, mea-
sured from the base of the fireplace to the flue
gas outlet of the termination, is 14.5 feet for
straight flue or a flue with one elbow set. The
maximum distance between elbows is 6 feet.
For systems with two elbow sets, the minimum
height is 22 feet. The maximum height of any
system is 50 feet. This measurement includes
the fireplace, chimney sections and the height
of the termination assembly at the level of the
flue gas outlet (see Figure 18, page 11).
41.375"
21.875"
41.250"
Figure 1 - Framing Dimensions
17.253"
MAINTAIN 3/4"
CLEARANCE A T
SIDES AND BACK
OF FIREPLACE
Minimum/Maximum Chimney Height for
Outdoor Installation
52.183"
The minimum height of the chimney, mea-
sured from the base of the fireplace to the
flue gas outlet of the termination, is 7 1/2 feet
(minimum of 4 feet of chimney pipe sections
required for outdoor installation).
24.399"
3
/
4" CLEARANCE
NOT REQUIRED A T
NAILING FLANGES
73.798"
Figure 2 - Corner Installation
4
Download from Www.Somanuals.com. All Manuals Search And Download.
111026-01J
FiReplace installatiOn
WARNING:Hearthextension
is to be installed only as shown
in Figure 3.
Continued
DRAIN PAN (DP36)
For outdoor installations, the fireplace enclo-
sure must allow for adequate drainage and
fresh air ventilation. It is recommended that
a sealed, corrosion resistant catch pan with
provision for drainage be installed under the
fireplace within the fireplace enclosure (see
Accessories on page 16).
MANTELS
A mantel may be installed if desired (see
Figure 4). Woodwork such as wood trims,
mantels or any other combustible material
projecting from the front face must not be
placed within 12" of the fireplace opening.
Combustible materials above 12" and pro-
HEARTH ExTENSION
A hearth extension projecting a minimum of jecting more than 11/2" from the fireplace
16" in front of and a minimum of 8" beyond must not be placed less than 15" from the
each side of the fireplace opening is required top opening of the fireplace (NFPA STD 211,
to protect combustible floor construction Sec. 7-3.3.3).
in front of the fireplace. Fabricate a hearth
extension using a material which meets the
following specifications: a layer of noncom-
bustible, inorganic material having a thermal
conductivity of K=0.84 BTU IN/FT, HR. F (or
less) at 1" thick. For example, if the material
selected has a K factor of 0.25, such as glass
fiber, the following formula would apply:
Mantels or any other combustible material
also may come up to the side edge of the
black metal face of the fireplace just as long
as the projection from the front face fall within
the limit shown in Figure 4.
Combustible
12 1/4" Ref.
Material
0.25 x 1.0" = 0.30" thickness required
0.84
Safe
Zone for
6"
Projection of
Combustible
Materials
Thermal conductivity "K" of materials can be
obtained from the manufacturer or supplier of
the noncombustible material. If the hearth ex-
tension is to be covered, use noncombustible
material such as tile, slate, brick, concrete,
metal, glass, marble, stone, etc. Provide a
means to prevent the hearth extension from
shifting and seal gap between the fireplace
frame and hearth extension with a noncom-
bustible material (see Figure 3).
Ref.
33°
3" Nom.
11/2" Max.
12" Min.
Upper
Section of
Fireplace
9" Min.
Fireplace Opening
Seal Gap
Fireplace Front
Top View of Fireplace
Ember Protector
FIREBOX
8.0"
33°
Fireplace Front
Raised Hearth
2" Max.
SAFE ZONE
3.0"
Ember Protector
Hearth
Extension
Combustible
Material Must
Not Overlap
Front Face
Min. to
Perpendicular
Side Wall
12"
Fireplace Front
Elevated
Seal Gap
Figure 4 - Mantel Clearances to
Combustible Material
Ember Protector
Figure 3 - Hearth Extension
111026-01J
Download from Www.Somanuals.com. All Manuals Search And Download.
5
Venting installatiOn
OPTIONAL OUTSIDE AIR KIT
WARNING: The opening in
collar around chimney at top of
fireplace must not be obstruct-
ed. Never use blown insulation
to fill chimney enclosure.
(MODEL AK4/AK4F)
The installation of an outside air kit should be
performed during the rough framing of the fire-
place due to the nature of it's location. Outside
combustion air is accessed through a vented
crawl space (AK4F) or through a sidewall (AK4).
See Figure 22 on page 13 for instruction of
operating air kit.
LINEAL GAIN
PART NO.
36"
DESCRIPTION
GAIN
Fireplace
40"
12-8DM
12-8HT
18-8DM
18-8HT
24-8DM
24-8HT
36-8DM
36-8HT
48-8DM
48-8HT
Pipe Section
Pipe Section
Pipe Section
Pipe Section
Pipe Section
10 5/8"
16 5/8"
23 5/8"
34 5/8"
46 5/8"
CAUTION: Combustion air
inlet ducts shall not terminate
in attic space.
The maximum height for the
air vent can not exceed 3 feet
below the flue gas outlet of the
termination.
6 7/8"
7 3/4"
*
*
RT-8DM Round Termination
RTL-8DM Round Termination
Secure to Collars with Metal Tape, Screws
or Straps (Min. of 1/4" x 20" in size)
Round Termination 6 7/8" to
with Slip Section
23 1/8"*
Round Termination 8 1/2" to
RTT-8DM
Air Inlet
RTTL-8DM
with Slip Section
21 1/2"*
Location
Must Allow
For Bushes
or Snow
*
ET-8DM Square Chase-Top
12
"
Square Chase-Top
*
ETO-8DM
12
"
with Mesh
Square Chase-Top
with Slip Section
7" to 15"*
ETL-8DM
Square Chase-Top
ETLO-8DM with Mesh & Slip
Section
12
"
to
*
25 1/2"
Air Inlet
Eyebrow
* The lineal gain for the terminations is mea-
sured to the flue gas outlet height.
Vent Hood
Vented Crawl Space
Required for
12 3/8" Galvanized
Outer Pipe
(Check Local Codes
Wall Installation
Before Installing in a
Vented Crawl Space)
Hemmed
Figure 5 - Outside Air Kit
8" Stainless
End
Inner Pipe
CHIMNEY PIPE
The FMI PRODUCTS, LLC chimney system
consists of 12", 18", 24", 36" and 48" snap-
lock, double-wall pipe segments, planned
for maximum adaptability to individual site
requirements. Actual lengths gained after fit-
ting overlaps must be taken into consideration
(lineal gain) and are given in the lineal gain
chart (see Figure 6). Lineal gain is the actual
measurable length of a part after two or more
parts are connected. For Canada, use chimney
parts designated "HT".
Figure 6 - Lineal Gain
A
SSEMBLY AND INSTALLATION OF
DOUBLE WALL CHIMNEY SYSTEM
Each double wall chimney section consists
of a galvanized outer pipe, a stainless steel
inner flue pipe and a wire spacer. The pipe
sections must be assembled independently
as the chimney is installed.
6
111026-01J
Download from Www.Somanuals.com. All Manuals Search And Download.
Venting installatiOn
Continued
When connecting chimney directly to the fireplace,
OFFSET RISE
CHIMNEY LENGTH
the inner flue pipe section must be installed first
with the lanced side up. The outer pipe section
can then be installed over the flue pipe section with
the hemmed end up. Press down on each pipe
section until the lances securely engage the hem
on the fireplace starter. The wire will assure the
proper spacing between the inner and outer pipe
sections. Continue to assemble chimney sections
as outlined, making sure that both the inner and
outer pipe sections are locked together. When
installing double wall snap-lock chimney together,
it is important to assure the joint between the chim-
ney sections is locked. Check by pulling chimney
upward after locking. The chimney will not come
apart if properly locked. It is not necessary to add
screws to keep the chimney together (exception -
see Figure 9, page 8).
A
B
48" 36" 24" 18" 12"
4 3/8" 16 3/8"
9 3/4" 25 1/2"
12 3/4" 30 3/4"
15"
18"
21 1/4" 46 1/4"
23 3/4" 49 1/4"
27 3/4" 56 3/4"
30"
33"
ELBOW SET ONLY
1
1
34 3/4"
40"
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
60 3/4"
66"
71"
1
1
36"
38 1/4"
75"
2
1
2
41 1/4" 80 1/4"
1
1
45"
46 3/4" 89 1/2"
51"
53 1/4"
56 1/4" 106 1/4"
59 1/4" 111 1/2"
61 3/4" 115 1/2"
64 3/4" 120 3/4"
68 1/4"
70"
86 3/4"
1
1
97"
101"
1
2
USING ELBOW OFFSETS (30E-8DM)
1. To achieve desired offset, you may install
combinations of 12", 18", 24", 36" and 48"
length of double wall pipe (see offset chart
and Figure 7).
2
1
2
2
1
2
1
1
1
2
1
2. Chimney weight above offset rests on
return elbow. Straps must be securely
nailed to rafters or joists (see Figure 8,
details A and B on page 8).
127"
130"
1
1
74 1/4" 137 1/2"
76 3/4" 141 1/2"
79 3/4" 146 3/4"
2
2
4
3. Maximum length of pipe between supports
(return elbow or 12S-8DM) is 6' of angle
run. Maximum of two 6' angle run sections
per chimney system (see Figure 7).
OFFSET CHART (22-50 FT. SYSTEM HEIGHT)
4. All pipe connections between offset and
return must be secured with two screws
on outer pipe only (see Figure 9, page 8).
Do not penetrate inner stainless.
Return
Elbow
Return
Elbow
Return
Elbow
Offset
Elbow
Offset
Elbow
6' Max.
6' Max.
6' Max.
Ceiling
Support Pipe
12S-8DM
Return
Elbow
Return
Elbow
6' Max.
Offset
Elbow
Offset
Elbow
6' Max.
6' Max.
Offset
Elbow
A
B
C
Figure 7 - Typical Offset Terminations
111026-01J
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Venting installatiOn
Continued
See Detail A
2" Min.
Existing
Ceiling
Frame
Firestop
Spacer
Straps
Detail B
Straps
Angle Firestop
Screws or
Staples
(Min. of 8)
See Detail B
Figure 10 - Firestop Spacer with Living
Space Above Ceiling
Screws or Staples
(Min. of 8)
Firestop
Spacer
Straps
Straps
Existing
Ceiling
Frame
Detail A
Return Elbow
Figure 8 - Ceiling Support Pipe
12S-8DM
Figure 11 - Firestop Spacer with Attic
Space Above Ceiling
Screws
B
PENETRATING ROOF
To maintain a 1" clearance to the pipe on a
roof with a pitch, a rectangular opening must
be cut.
1. Determine center point through which pipe
will penetrate roof.
A
2. Determine center point of roof. Pitch is the
distance the roof drops over a given span,
usually 12". A 6/12 pitch means that the
roof drops 6" for each 12" one measure
horizontally down from the roof rafters.
Figure 9 - Elbow Offset
FIRESTOP SPACERS (3600FS-8DM-1)
Firestop spacers are required at each point
where the chimney penetrates a floor space.
Their purpose is to establish and maintain
the required clearance between the chimney
and the combustible materials. When the pipe
passes through a framed opening into a living
space above, the firestop must be placed onto
the ceiling from below as shown in Figure 10.
3. Use roof opening chart (Figure 12, page
9) to determine the correct opening length
and flashing required.
4. Remove the shingles around opening
measured. Cut out this section.
5. Add next sections of pipe until end pen-
etrates roof line. Check to see that the
proper clearances are maintained. Extend
chimney by adding sections of double wall
pipe until pipe is minimum of 30" above the
highest point of the roof cutout.Termination
and chimney must extend a minimum of
36"abovethehighestpointwhereitpasses
through the roof.
They also provide complete separation from
one floor space to another or attic space as
required by most codes. When the double wall
pipe passes through a framed opening into an
attic space, the firestop must be placed into an
attic floor as shown in Figure 11.
8
111026-01J
Download from Www.Somanuals.com. All Manuals Search And Download.
Storm Collar Installation (SC1 or SC2)
Place storm collar over pipe and slide down
until it is snug against the open edge of the
flashing (see Figure 14). Use SC1 for all round
terminations and SC2 for all terminations with
slip sections.Apply waterproof caulk around the
perimeter of the collar to provide a proper seal.
Venting installatiOn
Continued
Minimum Measurements
14 3/8"
(36.5 cm)
30"
1"
(76.2 cm)
(2.5
cm)
1"
(2.5 cm)
Chimney
Pipe
Waterproof
Caulk
1"
(2.5
cm)
Storm
Collar
Flashing
Opening "A"
Pitch
Slope Opening "A" Used Flashing
Max.
15"
16 1/8"
Model No.
V6F-8DM
V6F-8DM
Figure 14 - Storm Collar
Terminations/Spark Arrestor
Flat
0°
0-6/12
26.6°
6/12-
12/12
The fireplace system must be terminated with
the listed round top or chase terminations. In
any case, refer to the installation instructions
supplied with the termination. The termination
approved for this fireplace are the RT-8DM and
RTL-8DMthatcanbeusedforflashingorchase
and ET-8DM, ETO-8DM, ETL-8DM and ETLO-
8DM for chase style termination only. Figure 15
shows an RTL-8DM round top termination.
45.0°
20 3/8"
V12F-8DM
Figure 12 - Roof Opening Measurements
FLASHING INSTALLATION (V6F-8DM
OR V12F-8DM)
Determine the flashing to be used with the roof
opening chart. Slide flashing over pipe until
base is flat against roof. Replace as many
shingles as needed to cover exposed area
and flashing base. Secure in position by nail-
ing through shingles (see Figure 13). DO NOT
NAIL THROUGH FLASHING CONE.
CAUTION: Do not seal open-
ingsontherooftopflashing.Fol-
low the installation instructions
provided with the termination
being used.
Installing Flashing on a Metal Roof
When installing flashing on a metal roof, it is
required that putty tape be used between the
flashingandroof.Theflashingmustbesecured
to the roof using #8 x 3/4" screws and then
sealed with roof coating to prevent leakage
through screw holes.Aroof coating must also be
applied around perimeter of flashing to provide
a proper seal.
Attach Bracket
Tabs to
RTL-8D
Outer Pipe
(3 Places)
Secure with
Screws
Level of
Flue Gas
Outlet
Storm Collar
Overlap
Shingles Top
and Sides Only
Caulk
Collar
Overlap
Shingles Top
and Sides
Flashing
Cone
Nail Only
Flashing
Outer
Perimeter
of Flashing
Underlap
Shingles
Bottom Only
Underlap Shingles
at Bottom
Figure 13 - Flashing Installation
Figure 15 - Termination
111026-01J
Download from Www.Somanuals.com. All Manuals Search And Download.
9
Venting installatiOn
Continued
Terminations with 16" slip pipe sections are
10 FOOT RULE
available. The RTT-8DM and RTTL-8DM are
approved for flashing installations. When
needed, these adjustable terminations may be
used in combination with the pipe assembly to
achieve the correct chimney height.
All flue gas outlet chimney terminations must
extend a minimum of 3 feet in height above the
highest point where it passes through the roof
and must be at least 2 feet above the high-
est point of the roof that is within a horizontal
distance of 10 feet (see Figure 17).
Note: In the rare instance there is a problem
with the side driven rain or wind or the chim-
ney is not drafting properly, an ADS-8DM
(Anti-Draft Shield) can be used with round
terminations.
Level of
Flue Gas
10'
Outlet
10'
CHASE INSTALLATIONS
2' Min.
3' Min.
Instructions for chase installations are
included with the chase style termination
chosen. In a multiple chase installation, be
sure to provide adequate distance between
terminations to prevent smoke spillage from
one termination to another. We suggest that
terminations be separated at least 24", center
to center and stacked at a vertical height dif-
ference of 18" (see Figure 16).
2' Min.
3' Min.
Figure 17 - 10 Foot Rule
FINISHING FIREPLACE
Note: If a decorative shroud is to be installed,
Combustible materials, such as wallboard,
gypsum board, sheet rock, drywall, plywood,
etc. may make direct contact with sides and top
around the fireplace face. It is important that
combustible materials do not overlap the face
itself. Brick, glass, tile or other noncombustible
materials may overlap the front face provided
they do not obstruct essential openings like
louvered slots or any other opening. When
overlapping with a noncombustible facing
material, use only noncombustible mortar or
adhesive.
contact the manufacturer for specifications.
18"
Min.
Typ.
24" Min.
24" Min.
Figure 16 - Multiple Chase Installation
10
111026-01J
Download from Www.Somanuals.com. All Manuals Search And Download.
Venting installatiOn
Continued
EFFECTIVE HEIGHT
EFFECTIVE HEIGHT
OF TERMINATION CAP OF TERMINATION CAP
MIN. HEIGHT
OF 22 FT. (WITH
2 ELBOW SETS)
MAX. HEIGHT OF
50 FT.
MAX. HEIGHT
50 FT.
(ANY SYSTEM)
EFFECTIVE HEIGHT
EFFECTIVE HEIGHT
OF TERMINATION CAP OF TERMINATION CAP
14.5 FT.
MINIMUM
HEIGHT
14.5 FT.
MINIMUM
HEIGHT
UP TO
6FT. MAX.
UP TO
6FT. MAX.
30E-8DM
30E-8DM
Figure 18 - Typical Residential Installations
OptiOnal gas line installatiOn
Gas line hook up should be done by your
supplier or a qualified service person.
(see Figure 20, page 12). Note: Secure
incoming gas line to wood framing to
provide rigidity for threaded end.
Note: Before you proceed, make sure your
gas supply is turned off.
4. Repack insulation around gas line and into
sleeve opening. Seal any gaps between
gas line and refractory knockout hole with
refractory cement or commercial furnace
cement, Install the gas appliance or cap-
off gas line if desired.
Use only a 1/2" black iron pipe and appropri-
ate fittings.
1. Remove knockout indentation on refrac-
tory or firebrick wall located above the
refractory hearth floor. The knockout
indentation must be firmly tapped with any
solid object such as a 1/2" dowel until it is
released. Remove fragmented portions of
refractory (see Figure 19).
Side
Outside of
Firebrick
Fireplace
Finished
Side
Gas Line
Conduit
2. Remove gas line cover plate located on
either side of fireplace and pull out insu-
lation from gas line conduit sleeve. Save
insulation for reuse. Replace screws.
1/2" Dowel
Insulation
3. Run a 1/2" black iron gas line into the
fireplace through the rear at gas line
conduit sleeve (if using a raised platform,
add height). Provide sufficient gas line into
fireplace chamber for fitting connection
Gas
Conduit
Cover
Refractory
Knockout
Plug
Figure 19 - Gas Line Knockout
111026-01J
11
Download from Www.Somanuals.com. All Manuals Search And Download.
OptiOnal gas line installatiOn
Continued
CAUTION: All gas piping
andconnectionsmustbetested
for leaks after the installation
is completed. After ensuring
that the gas valve is on, apply
soap and water solution to all
connectionsandjoints.Bubbles
forming show a leak. Correct
all leaks at once. DO NOT USE
AN OPEN FLAME FOR LEAK
TESTING AND DO NOT OPER-
ATEANYAPPLIANCEIFALEAK
IS DETECTED. LEAK TESTING
SHOULDBEDONEBYAQUALI-
FIED SERVICE PERSON.
WARNING: Do not operate an
unvented gas log set in this fire-
place with the chimney removed.
If you install a decorative gas appliance
(vented gas log), the decorative gas appliance
must comply with the Standard for Decorative
Gas Appliance for Installation in Solid Fuel
Burning Fireplaces, ANS Z21.60, Z21.84 or
RG 2-72 and shall also be installed in accor-
dance with the National Fuel Gas Code, ANSI
7223NFPA 54 latest edition.
WARNING:Toavoidtheriskof
damagingthefireplacematerials
andincreasingtheriskofspread-
ingafire,donotusethefireplace
to cook or warm food.
Note: A FMI PRODUCTS, LLC hood must be
installed when using an unvented gas log set
(see Accessories on page 16).
WARNING: If the fireplace
hasbeenusedforwoodburning,
thefireboxandchimneymustbe
cleaned of soot, creosote and
ashes be a qualified chimney
cleaner. Creosote will ignite if
heavily heated.
Side
Outside of
Firebrick
Fireplace
Incoming
1/2" Black
Iron Pipe
Finished
Side
Gas
Line
Conduit
Seal
Opening
with
Refractory
Cement
WARNING: When using a
decorative vented gas log, the
damper must be removed or per-
manentlylockedinthefullyopen
positionandtheglassdoorsmust
be in the fully open position.
Repack
Insulation
Provide Enough Threaded
End for Fitting Connection
Figure 20 - Gas Line Installation
OpeRatiOn and Maintenance guidelines
GLASS DOORS
Glass doors are optional with the fireplace.
When the fireplace is in operation, doors
must be fully opened or fully closed position
only or a fire hazard may be created (see
Figure 21).
Doors Fully Closed
Fireplace Front
A fireplace equipped with glass doors oper-
ates mush differently than a fireplace with an
open front. A fireplace with glass doors has a
limited amount of air for combustion. Exces-
sive heat within the fireplace can result if too
large a fire is built or if the combustion air gate
is not completely open.
Doors
Fully Opened
Fireplace Front
Figure 21 - Glass Doors
12
Download from Www.Somanuals.com. All Manuals Search And Download.
111026-01J
OpeRatiOn and Maintenance guidelines
Continued
The following tips should be followed to as-
sure that both the fireplace and the glass door
retain their beauty and function properly. Both
the flue damper and the glass doors must be
fully opened before starting the fire. This will
provide sufficient combustion air and maintain
safe temperatures in the firebox.
OUTSIDE AIR AND DAMPER
HANDLE OPERATION
The damper handle, which opens and closes
the damper blade, is located in the upper front
face of the fireplace. Pushing the handle into
the left of the keyway slot will free the damper
blade to automatically open. Pushing the
handle in to the right will lock the damper
blade closed (see Figure 22).
IMPORTANT: The glass must be allowed to
warm slowly and evenly. The tempered glass
will withstand a gradual temperature rise to
550° F, which is more than a normal fire will
generate. Such materials as pitch/wax laden
logs, very dry mill end lumber and large
amounts of paper or cardboard boxes can
create an excessively hot fire and should not
be burned in this fireplace. Always keep the
fire well back from the doors and never allow
flames to contact the glass.
The outside air kit handle is located at the left
hand side of the fireplace (see Figure 22).
Pulling the handle out will free the outside air
door to open. Pushing the handle in will lock
the door closed.
WARNING: Risk of fire! Re-
placegratewithFMIPRODUCTS,
LLC model 111028-01 only. This
gratehasbeendesignedtokeep
the operation of your fireplace
safe and efficient.
WARNING: Fireplaces
equipped with glass doors
should be operated only with
doorsfullyopenedordoorsfully
closed.Doors,ifleftpartlyopen,
may draw gas and flame out of
the fireplace opening creating
risks of both fire and smoke.
For further operating guidelines, instructions
and warranty information, please refer to your
homeowner's guide or contact your authorized
dealer.
Damper
Handle
Cleaning Glass
Clean the glass with any commercial glass
cleaner or soap and water. Do not use any
abrasive material to clean the glass. Do not
clean the glass with any cool water is the glass
is still hot from the fire and smoke.
Keyway
Slot
A gas line or gas log lighter may be installed
for the purpose of installing a vented or vent-
free decorative gas appliance incorporating an
automatic shutoff device and complying with
the Standard for Decorative Gas Appliances
for Installation in Vented Fireplaces, ANSI
Z21.60 or American Gas Association draft
requirements for Gas Fired Log Lighters for
Wood Burning Fireplaces, Draft NO. 4 dated
August, 1993.
Outside Air
Kit Handle
Handle
Retainer
Figure 22 - Damper and Air Kit Handle
If you wish to install an unvented (vent-free)
gas log set, only unvented gas log sets which
have been found to comply with the standard
for unvented room heaters,ANSI Z21.11.2 are
to be installed in this fireplace.
111026-01J
Download from Www.Somanuals.com. All Manuals Search And Download.
13
paRts
WOOD BURNING FIREPLACE MODELS
S36, S36H, S36R, S36RH, S36-LS, VS36, VS36H, VS36R AND VS36RH
35
29
2
1
21
5
8
15
17
28
20
30
25
9
18
19
11
37/38
7
12
34
3
36
31
4
24
26
10
32
6
33
22
16
13
27
14
16
23
27
14
Download from Www.Somanuals.com. All Manuals Search And Download.
111026-01J
paRts
WOOD BURNING FIREPLACE MODELS S36, S36H, S36R, S36RH, S36-LS,
VS36, VS36H, VS36R AND VS36RH
This list contains replaceable parts used in your fireplace.
KEY
NO. PART NO. DESCRIPTION
QTY.
1
1
1
1
1
1
1
1
1
1
1
1
1
4
1
2
1
1
1
1
1
1
1
1
1
2
2
1
1
2
2
1
2
2
4
4
2
2
1
2
3
4
5
6
7
8
9
106638-01 Insulation Pan
** Fireplace Top
106641-01 Fireplace Surround
106642-01 Air Rod Retainer
106643-01 Damper Rod Retainer
**
**
**
Firebox Bottom
Firebox Surround
Air Separator
See Below Left Refractory
10 See Below Right Refractory
11 See Below Rear Refractory
12 See Below Bottom Rear Refractory
13 See Below Bottom Front Refractory
14 106683-01 Firebox Support Leg
15 106687-01 Damper Can Collar
16 106691-01 Screen Rod
17
18 106703-01 Air Kit Door Assembly
19 ** Face Weldment
**
Firebox Top Assembly
20 110892-01 Air Deflector
21 111327-01 Fireplace Top Insulation
22 107775-01 Access Panel
23 107854-01 Right Refractory Bracket
24 107854-02 Left Refractory Bracket
25 111028-01 Grate
26 11418
27 110890-01 Stainless Screen
Push-On Nut
28 16405
29 20023
30 20027
31 106539-02 Grate Retainer
32 111073-01 Door Stop
33 111204-01 Pivot Clip
34 20090
35 20280
36 21171
37 21379
38 21380
Collar Insulation
Chimney Starter Collar
Refractory Retainer
Spring Clip
Top Spacer
Conduit Plate Cover
Gas Conduit
Gas Conduit
PARTS AVAILABLE NOT SHOWN
106625-01 Home Owner’s Guide
1
2
20093
Ember Protector
** Not a field replaceable part
111026-01J
Download from Www.Somanuals.com. All Manuals Search And Download.
15
paRts
WOOD BURNING FIREPLACE MODELS S36, S36H, S36R, S36RH, S36-LS,
VS36, VS36H, VS36R AND VS36RH
Right Side
Rear
Bottom
Front Bottom
Left Side
REFRACTORY BRICK
KEY
NO. PART NO. DESCRIPTION
QTY.
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
9
106658-03 Left Refractory, Textured White Brick
108164-03 Left Refractory, Textured White Herringbone
106658-02 Left Refractory, Textured Red Brick
108164-02 Left Refractory, Textured Red Herringbone
106658-01 Left Refractory, Smooth White Brick
108164-01 Left Refractory, Smooth White Herringbone
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
10 106659-03 Right Refractory, Textured White Brick
108165-03 Right Refractory, Textured White Herringbone
106659-02 Right Refractory, Textured Red Brick
108165-02 Right Refractory, Textured Red Herringbone
106659-01 Right Refractory, Smooth White Brick
108165-01 Right Refractory, Smooth White Herringbone
11 106660-03 Rear Refractory, Textured White Brick
108166-03 Rear Refractory, Textured White Herringbone
106660-02 Rear Refractory, Textured Red Brick
108166-02 Rear Refractory, Textured Red Herringbone
106660-01 Rear Refractory, Smooth White Brick
108166-01 Rear Refractory, Smooth White Herringbone
12 110899-01 Bottom Rear Refractory, White Brick
110899-02 Bottom Rear Refractory, Red Brick
•
•
•
1
1
1
1
1
1
•
•
•
•
•
•
•
•
•
•
•
•
•
•
13 110900-01 Bottom Front Refractory, White Brick
110900-02 Bottom Front Refractory, Red Brick
•
16
Download from Www.Somanuals.com. All Manuals Search And Download.
111026-01J
technical seRVice
You may have further questions about installation, operation, or troubleshooting. If so, contact
FMI PRODUCTS, LLC at 1-866-328-4537. When calling please have your model and serial
numbers of your heater ready.
accessORies
DOUBLE WALL PIPE
12-8DM 12-8HT
18-8DM 18-8-HT
24-8DM 24-8HT
36-8DM 36-8HT
48-8DM 48-8HT
BI-FOLD GLASS DOOR
BDO36 - Black
BDO36B - Brushed Brass
BDO36P - Platinum
ROOF FLASHING
0 TO 6/12 PITCH - V6F-8DM
6/12 TO 12/12 PITCH - V12F-8DM
30° OFFSET AND RETURN
30E-8DM
ANTI-DRAFT SHIELD
(Round Top Termination Only)
ADS-8DM
FIRESTOP SPACER
3600FS-8DM-1
HOOD
STAINLESS STEEL- HS36
Required when installing a vent-free gas log
in this fireplace.
DRAIN PAN DP36
111026-01J
17
Download from Www.Somanuals.com. All Manuals Search And Download.
accessORies
Continued
ROUND TOP
TERMINATIONS
RT-8DM, RTL-8DM
ROUND TOP
TERMINATIONS
WITH SLIP SECTION
RTT-8DM, RTTL-8DM
OUTSIDE AIR KIT FOR SIDE WALL
INSTALLATION - AK4
ROUND TOP
TERMINATIONS
WITH LOUVERS
RTL-8DM
OUTSIDE AIR KIT FOR FLOOR
INSTALLATION - AK4F
STORM COLLAR
SC1-1 For RT-8DM and RTL-8DM
SC2-1 For RTT-8DM and RTTL-8DM
SQUARE CHASE-TOP
TERMINATION
ET-8DM, ETO-8DM
ECONO-TOP TERMINATION WITH
SLIP SECTION
ETL-8DM, ETLO-8DM
18
Download from Www.Somanuals.com. All Manuals Search And Download.
111026-01J
nOtes
_____________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
_____________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
_____________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________
______________________________________________________