Model 8/10 PLUS Introduction and Specifications .............Chapter 1  
About this Manual ................................................................. 1-1  
Facts and Features ............................................................... 1-1  
Description of Features ................................................. 1-2  
Specifications ....................................................................... 1-3  
Model 8/10 PLUS Operation and Configuration.................Chapter 2  
Operation and Front Panel Descriptions ............................... 2-1  
Rear Panel Descriptions ....................................................... 2-2  
Installation Guide .................................................................. 2-3  
Model 10 PLUS Diagram ...................................................... 2-4  
Output Select DIP Switch Setting ......................................... 2-5  
Example Select DIP Switch Settings .................................... 2-6  
Changing the Baud Rate ...................................................... 2-7  
Model 8/10 PLUS Switcher Connection to Computer ........... 2-8  
Triple Action SwitchingTM ...................................................... 2-8  
Model 8/10 PLUS RS-232 Control .....................................Chapter 3  
RS-232 connector location and pin assignments ................. 3-1  
Software ........................................................................ 3-1  
Host/Switcher Communications..................................... 3-1  
Using the Command/Response Table ........................... 3-1  
Command/Response Table................................................... 3-2  
Software................................................................................ 3-3  
Installing the Software ................................................... 3-3  
Using the Software ........................................................ 3-3  
Configuring Features and Options .................................. Appendix A  
MANUAL REMOTE Connector ............................................. A-1  
KP-10 Hard Wired Remote Control ...................................... A-2  
IR-10 Infrared Remote Control ............................................. A-3  
Rack Mounting the Model 8/10 PLUS Switchers .................. A-4  
Accessories/Part Numbers ................................................... A-5  
Warranty .....................................................Inside of back cover  
Safety Instructions ...................................... Inside of front cover  
Written and Printed in the U.S.A.  
Model 8/10 PLUS  
User's Manual  
68-080-01  
Rev. E  
79-11  
Page i  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Legend of Icons  
The following icons may be used in this manual:  
___ Important information – for example, an action or a step that  
must be done before proceeding.  
___ A Warning – possible damage could occur.  
_ A Note, a Hint, or a Tip that may be helpful.  
__ Possible Electrostatic Discharge (ESD) damage could result  
from touching electronic components.  
__ Additional information may be referenced in another section, or  
in another document.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Extron’s Model 8/10 PLUS Switchers  
User’s Manual  
Chapter One  
Model 8/10 PLUS Switcher  
Introduction  
Features  
Specifications  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
Model 8/10 PLUS Introduction and Specifications  
Introduction  
About This Manual  
This manual includes operation, configuration and option  
information for the Model 8 PLUS and Model 10 PLUS (Model  
8/10 PLUS) Switchers.  
Model 8/10 PLUS Facts and Features  
The Model 8/10 PLUS Switchers enable selection of anyone  
of eight (or ten) inputs with the following formats:  
RGBS  
RGsB  
S-Video/SVHS (Y/C) w/Stereo Audio follow  
Composite Video (NTSC/PAL) w/Stereo Audio follow  
The output video format of the Model 8/10 PLUS switchers  
will always be the same as the selected input video format.  
Standard features of the Model 8/10 PLUS switchers are:  
Bandwidth = 300 MHz  
Front Panel Control of Input Selection  
Manual Remote Control Port  
RS-232 Control Port  
BNC Connector Inputs  
Rear Panel Input LED Indicators  
Unused Inputs Terminated at 75 ohms  
BNC and S-Video Output Connectors  
Triple Action SwitchingTM  
Audio (Stereo) Follow capable with Composite or S-Video  
Internal Switch Mode Power Supply  
Available Models and Part Numbers are:  
Model 8 PLUS Switcher – 60-094-01  
Model 10 PLUS Switcher – 60-095-01  
The Model 8 PLUS front and back panels are shown below.  
1
2
3
4
5
6
7
8
Page 1-1  
Extron • Model 8 PLUS & Model 10 PLUS Switchers • User’s Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Model 8/10 PLUS Introduction and Specifications  
Description of Features  
Outputs – Because switching is direct, the output will always have  
the same format as the selected input. Separate output  
connectors are provided for RGBS, S-Video, Composite  
Video, and Audio.  
300 MHz Bandwidth – The wide bandwidth allows signals to be  
passed without loss of resolution. This is extremely important  
when using high resolution computer workstations.  
Triple Action SwitchingTM (RGB Delay) – Triple Action  
SwitchingTM is a technique in which the RGB video is blanked  
for a brief period when a new input is selected. This prevents  
a distorted image from being displayed during the time the  
display device sync circuitry is locking onto the new sync  
input. When an input is selected, Triple-Action Switching®  
does this:  
1. Drop the RGB video signals leaving sync connected.  
2. Wait for 20 mS and then switch to the new sync signal.  
3. Wait for the time delay set by the user (0.0 - 7.5 seconds)  
and then switch to the new RGB signals. (During this time  
the projector is setting up to match the new sync.)  
Switcher Control – Each channel of the switcher can be  
controlled in any one of the following ways:  
1. Front Panel Buttons.  
2. Manual Remote Control Connector – KP-10 Wired  
Remote Control, IR-10 Infrared Remote Control or third  
party remote control.  
3. RS-232 Control Connector – Provides for computer/serial  
control of the switcher.  
Internal Power Supply – The Model 8/10 PLUS switchers have  
an internal, auto-switching (100 - 240 VAC, 50/60 Hz) power  
supply. The Model 8/10 PLUS switchers are UL, CE and CSA  
approved.  
Rear Panel LED Indicators – Rear panel LEDs indicate which  
input is selected and which outputs are active.  
The Model 10 PLUS front and back panels are shown below.  
1
2
3
4
5
6
7
8
9
10  
Extron • Model 8 PLUS & Model 10 PLUS Switchers • User’s Manual  
Page 1-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Model 8/10 PLUS Introduction and Specifications  
Specifications  
General  
Operation Temperature ....0°-50° C  
Storage Temperature ....-20°-70°  
MTBF Demonstrated ....30,000 Hours  
Approvals ....UL Listed, CSA, CE  
Dimensions ....17" W x 9.25" D x 3.31" H  
....43.2cm W x 23.5cm D x 8.4cm H  
Shipping Weights ....13.0 lbs.  
....5.9 kg  
Power Supply ....Internal 100-240 VAC, 50/60 Hz  
Warranty ....2 years parts and labor  
....(See warranty info-last page)  
Video  
Bandwidth ....300 MHz  
Crosstalk at 10 MHz ....-35 db (typical)  
Isolation at 10 MHz ....55 db (typical)  
Return loss at 10 MHz ....25 db  
Input Impedance ....75 Ohms  
Output Impedance ....75 Ohms  
Termination Impedance ....75 Ohms  
Sync Input Impedance ....510 Ohms  
Gain ....None  
Connectors ....Input Type  
....BNC (Female)  
....Output Type  
....BNC (Female)  
....4 Pin Mini-DIN (S -Video)  
1
2
3
4
5
6
7
8
9
10  
Page 1-3  
Extron • Model 8 PLUS & Model 10 PLUS Switchers • User’s Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Extron’s Model 8/10 PLUS Switchers  
User’s Manual  
Chapter Two  
Model 8/10 PLUS Switcher  
Operation and Installation  
Switcher Operation  
Front Panel  
Rear Panel  
Switcher Installation Guide  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
Model 8/10 PLUS Operation and Configuration  
Model 8/10 Switcher Operation  
The Model 8/10 PLUS switchers enable the output to be  
switched from anyone of 8 or 10 inputs (A)* and the following  
formats are supported:  
RGBS – RGB with separate composite sync  
RGsB – RGB with sync on green  
Monochrome Composite Video  
NTSC/PAL (Composite) Video w/Stereo Audio follow  
S-Video (SVHS) w/Stereo Audio follow  
When an input is selected, an LED will illuminate green next  
to the selected BNC input connectors on the rear panel (H)*.  
Three sets of output connectors are used for the four different  
video format outputs. They are:  
RGB (RGBS or RGsB) – 4 BNC connectors (B)*  
VIDEO (NTSC/PAL) – 1 BNC connector (C)*  
S-Video (SVHS) – 1 S-Video DIN connector (D)*  
Audio, if used, is available on the two output BNC connectors  
labeled AUDIO (L and R) (E)*.  
Only one set of output connectors is active at a time. The  
current active set is identified by an illuminated LED next to  
the active output connector(s) (F)*.  
The Output Select DIP Switch (G)* settings will determine  
which of the three output connectors that the selected input  
will be directed to. These switches must be set for each input  
to match the incoming format. There are two switch modules,  
the left switch module is for RGBS/S-Video selection and the  
right switch module is for RGBS/NTSC-PAL selection. The  
switch modules are numbered from top to bottom to match the  
input number.  
Front Panel  
The POWER LED (see front panel drawing below), when  
illuminated, indicates that the switcher power is on. If AC  
voltage is available to the switcher, it is powered on.  
Front Panel switches 1 – 10 (Model 8 = 1 – 8) shown in the  
drawing below may be used to select the input. The LED in  
the front panel switch for the selected input will be illuminated.  
* – (A) thru (K) refer to the drawing and descriptions on the  
facing page.  
Model 10 PLUS Front Panel  
Page 2-1  
Extron • Model 8 PLUS & Model 10 PLUS Switchers • User’s Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Model 8/10 PLUS Operation and Configuration  
Rear Panel  
The following descriptions are keyed* to the Model 10 rear  
panel drawing below.  
A
B
There are four BNC connectors per input. The Model 8 PLUS  
and Model 10 PLUS switchers have 8 and 10 sets of input  
connectors. See "Connecting the Inputs" on page 2-3.  
RGB output will be available on this set of four BNC  
connectors if the selected input video format is RGB and the  
S-Video/SVHS and NTSC/PAL DIP switch modules are set to  
RGBS for the selected input number.  
C
D
E
NTSC/PAL video output will be available on this BNC  
connector if the selected input video format is NTSC/PAL and  
the NTSC/PAL DIP switch module is set to VIDEO (S-Video/  
SVHS switch is set to RGBS) for the selected input number.  
S-Video output will be available on this DIN connector if the  
selected input video format is S-Video and the S-Video/SVHS  
DIP switch module is set to VIDEO (NTSC/PAL is set to  
RGBS) for the selected input number.  
Audio follow, if used, will be available on these two BNC  
connectors. Audio follow is valid only with NTSC/PAL or  
S-Video input video formats. The left connector is for the left  
audio channel and the right connector is for the right audio  
channel.  
F
These three LEDs are located next to the three video outputs  
and one of the three will illuminate to identify the connector(s)  
with video output for the selected video input.  
G
The switches within the two DIP switch modules are used to  
identify the format of each video input and to steer the video to  
the proper output connectors.  
H
I
Selected input LEDs.  
AC line voltage input connector.  
J
K
RS-232 connector - See page 3-1 for a detailed description.  
Remote connector - See page A-1 for a detailed description.  
* – Letters next to the descriptions above are keyed to the circled  
letters in the drawing below.  
1
2
3
4
5
6
7
8
9
10  
Extron • Model 8 PLUS & Model 10 PLUS Switchers • User’s Manual  
Page 2-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Model 8/10 PLUS Operation and Configuration  
Model 8/10 PLUS Switcher Installation Guide  
The recommended installation procedure for the Model 8  
PLUS and Model 10 PLUS Switchers is:  
1. Prior to installing the switcher (because it requires opening the  
case) do the procedure "Changing the Baud Rate" on page 2-7  
if necessary.  
2. If the switcher is to be rack mounted, install it in the rack using  
the procedure "Rack Mounting the Switcher" on page A-4.  
3. Connect switcher input and output cables using the diagram on  
the facing page as a general guide (also see "Connecting the  
Inputs" below).  
4. Set the Output Select DIP Switches using the procedure  
"Output Select DIP Switch Setting" on page 2-5.  
5. If the switcher RS-232 connector is to be used, connect it to  
the computer using the procedure "Model 8/10 Switcher  
Connection to Computer" on page 2-8.  
6. If the Extron KP-10 Remote Control is to be used, connect it to  
the switcher using the procedure on page A-2.  
7. If the Extron IR-10 Remote control is to be used, connect it to  
the switcher using the procedure on page A-3.  
8. If a third party remote control device is to be used, connect it to  
the switcher using the information on page A-1 as a guide.  
9. Upon completion of switcher installation, use "Model 8/10  
Switcher Operation" on page 2-1 as a guide to operate the  
switcher .  
10. If RS-232 control of the switcher is to be used, use Chapter 3,  
"Model 8/10 PLUS RS-232 Control" as a guide.  
_ If a projector is connected to the RGB output and picture  
sizing, rolling, or other forms of distortion occur for an instant  
after the input is switched, the Triple Action SwitchingTM  
adjustment on page 2-8 may be required.  
Connecting the Inputs  
Use the chart below as a guide to connecting inputs to the  
four BNC input connectors shown to the right. Use the inputs  
listed under the appropriate video format at the top of the  
table.  
RGBS  
RGsB  
S-Video/SVHS  
NTSC/PAL  
R = RED  
R = RED R (Right) Audio R (Right) Audio  
G = Green G = Green  
Y Video  
L (Left) Audio L (Left) Audio  
C Video Unused  
Video  
B = Blue  
Sync  
B = Blue  
Unused  
Page 2-3  
Extron • Model 8 PLUS & Model 10 PLUS Switchers • User’s Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Model 8/10 PLUS Operation and Configuration  
_ The S-Video output from the SVHS VCR would most likely  
require a user supplied S-Video to BNC adapter to connect to  
the Model 8 PLUS or Model 10 PLUS switcher. The Extron  
Part Number for an adapter of this type is 26-353-01.  
Composite video outputs and audio outputs from Laser Disc  
Players and VCRs will most likely require RCA to BNC  
adapters. An adapter of this type can generally be purchased  
at your local electronics store.  
Extron • Model 8 PLUS & Model 10 PLUS Switchers • User’s Manual  
Page 2-4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Model 8/10 PLUS Operation and Configuration  
Output Select DIP Switch Setting  
As mentioned earlier, the Output Select DIP switches must be  
set to define the video format of each input. The DIP Switch  
modules, labeled S-VIDEO/SVHS and NTSC/PAL are shown  
in the drawing at the bottom of this page. Each module has 10  
(8 if Model 8 PLUS) switches which are numbered to match  
the input numbers. RGBS and VIDEO labels under the switch  
modules identify the left and right switch positions. When  
setting the Output Select Switch Module switches, use the  
following rules as a guide:  
All RGB inputs must have the corresponding switch positions  
on both switch modules set to RGBS. If all switcher inputs are  
RGB format, all of the Output Select DIP switches must be set  
to the RGBS position.  
All S-Video inputs must have the corresponding switch  
positions on the S-VIDEO/SVHS module set to VIDEO. The  
corresponding NTSC/PAL switches must be in the RGBS  
position.  
All NTSC/PAL inputs must have the corresponding switch  
positions on the NTSC/PAL switch module set to VIDEO. The  
corresponding S-Video switches must be in the RGBS position.  
The DIP switch modules used in the Model 8/10  
PLUS switchers are the "rocker" type (see end  
view drawing to the left). The major difference  
between the rocker type and the "slide" type  
(which could also be used) is the action  
required to change the position of the switch.  
To change the position of the rocker  
type switch, press down on the  
desired end (RGBS or VIDEO) with  
a pointed object. To change the  
position of the slide switch, a small  
screwdriver is used to push (slide)  
the switch to the desired position  
(RGBS or VIDEO).  
See examples on facing page.  
Page 2-5  
Extron • Model 8 PLUS & Model 10 PLUS Switchers • User’s Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Model 8/10 PLUS Operation and Configuration  
Example Output Select DIP Switch Settings  
The diagram below shows five inputs of a Model 8 PLUS  
Switcher connected to the following devices:  
1. SVHS VCR (S-Video output to switcher)  
2. Extron RGB 112 PLUS Interface/Workstation  
3. Extron RGB 202xi Universal Interface/Laptop Computer  
4. Extron RGB 202xi Universal Interface/Personal Computer  
5. Laser Disc Player (Composite Video output to switcher)  
The output select DIP switch settings for this combination of  
inputs and the valid output connectors are:  
Switch Switch Module Switch Module Video Output  
#
1
2
3
4
5
S-Video/SVHS  
VIDEO  
NTSC/PAL  
RGBS  
RGBS  
RGBS  
RGBS  
Connector  
S-VIDEO DIN  
RGBS BNCs  
RGBS BNCs  
RGBS BNCs  
VIDEO BNC  
RGBS  
RGBS  
RGBS  
RGBS  
VIDEO  
_ Having both switch modules set to VIDEO for any switch  
position (Input #) is an invalid combination.  
Audio output will be available at the AUDIO output BNC  
connectors when input #1 or #5 is selected.  
The three video output types can be connected to a single  
display that is capable of accepting all three video formats as  
shown in the diagram, or, they can be split between two or  
three different output devices.  
1
2
3
4
5
6
7
8
Extron • Model 8 PLUS & Model 10 PLUS Switchers • User’s Manual  
Page 2-6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Model 8/10 PLUS Operation and Configuration  
Changing the Baud Rate  
The RS-232 protocol factory setting is 9600 baud, 8-bits, no  
parity, 1 start bit and 1 stop bit. The position of internal rotary  
switch SW3 on the main controller board controls the baud  
rate and parity. To change the switch setting, remove the four  
screws from the top of the case and lift the cover straight up.  
Locate SW3 (see drawing below) and use a small, flat blade  
screwdriver to rotate the switch to the desired position. SW3  
switch positions are defined in the table below.  
8-bit, no parity, 1 stop bit  
8-bit, odd parity, 1 stop bit  
0 = 300 baud  
1 = 600 baud  
2 = 1200 baud  
3 = 2400 baud  
4 = 4800 baud  
5 = 9600 baud  
6 = 19200 baud  
7 = 38400 baud  
8 = 300 baud  
9 = 600 baud  
A = 1200 baud  
B = 2400 baud  
C = 4800 baud  
D = 9600 baud  
E = 19200 baud  
F = 38400 baud  
_ Adjust SW3 to set the RS-232 Baud Rate and Protocol.  
SW3 Rotary Switch  
Page 2-7  
Extron • Model 8 PLUS & Model 10 PLUS Switchers • User’s Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Model 8/10 PLUS Operation and Configuration  
Model 8/10 PLUS Switcher Connection to Computer  
To connect the Model 8/10 to a computer, refer to the picture  
below and connect the user supplied RS-232 cable from the  
computer (PC) serial port to the Model 8/10 PLUS Switcher  
connector labeled RS-232.  
1
2
3
4
5
6
7
8
9
10  
Triple Action SwitchingTM (RGB Delay)  
This prevents image scrambling during switching time. When  
an input is selected, Triple Action Switching® does this:  
1. Drop the RGB signals.  
2. Wait 20 mS and then switch to the new sync signal.  
3. Wait for the time delay set by the user (0.0 - 7.5 seconds)  
and then switch to the new RGB signals. (During this time  
the projector is setting up to match the new sync.)  
SW9 is used to set the 0.0 - 7.5 second delay (See drawing  
on facing page). Each position of the switch changes the  
delay by 0.5 seconds and the adjustment range is 0.0 (Switch  
position 0) to 7.5 seconds (Switch position F). The switcher  
ships with SW9 set to the 0 position (0.0 seconds).  
To change the SW9 switch position, remove the four screws  
from the top of the case and lift the cover straight up. Use a  
small, flat blade screwdriver to rotate the switch to the desired  
switch position. The switch position can be calculated by  
measuring (estimating) the period of time that the video  
appears out of sync after switching to a new input, then  
multiply the time period by 2 to determine the switch position.  
Example:  
Measured out of sync period = 4 seconds  
4 x 2 = 8 (The required switch position for 4 seconds is #8.)  
The switch positions above 9 are labeled in hexadecimal, i.e.  
switch position 10 is labeled A on the switch. (10Dec = AHex  
11 = B, 12 = C, 13 = D, 14 = E and 15 = F)  
,
Extron • Model 8 PLUS & Model 10 PLUS Switchers • User’s Manual  
Page 2-8  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Notes:  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Extron’s Model 8/10 PLUS Switchers  
User’s Manual  
Chapter Three  
Model 8/10 PLUS RS-232 Control  
Host/Switcher Communications  
Command/Response Table  
Control Software  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Model 8/10 PLUS RS-232 Control  
Model 8/10 PLUS RS-232 Control  
The Model 8/10 PLUS switchers can be controlled through the  
RS-232 port by a Host device/system. The RS-232 connector  
location and pin assignments are shown in the drawing below.  
1
Software  
Each Model 8/10 PLUS switcher ships with a 3.5" diskette  
containing Extron's Windows® compatible UNIVSW Control  
Software which enables the user to select the input and check  
switcher status in a Windows “point and click” environment.  
This software will be covered later in this chapter.  
Host/Switcher Communications  
The Model 8/10 PLUS Switchers treat any character that  
comes in on the RS-232 port as a possible command but  
accepts only a limited number as legal commands. There are  
no codes required to say that a command is coming, or that a  
command has ended. A simple command may be a single  
character typed on a keyboard and does not require any  
special characters before or after. (i.e. It is not necessary to  
press “enter” from the keyboard.) Simple commands could be  
from a terminal, or any other controlling device.  
When the Model 8/10 PLUS switcher receives a command  
and determines that it is valid, it will execute the command  
and send a response back to the controlling (Host) device. If  
the command is determined by the Model 8/10 PLUS switcher  
to be invalid, an error response will be returned to the Host.  
All responses from the switcher to the Host begin and end  
with a carriage return and a line feed (CR/LF) signaling the  
end of the Response character string (string = one or more  
characters).  
Using the Command/Response Table  
The table on the following page lists those commands which  
the Model 8/10 PLUS switchers recognize as valid and the  
responses that will be returned to the Host. The Description  
column defines the Command, the results of executing the  
Command, or a definition of the response.  
The Command string in the left hand column of the table is  
defined in the right hand column. The Command string is  
shown as ASCII characters, an ASCII to HEX conversion  
table is provided.  
Page 3-1  
Extron • Model 8 PLUS & Model 10 PLUS Switchers • User’s Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Model 8/10 PLUS RS-232 Control  
Command/Response Table  
Definitions and Abbreviations:  
V = Input channel, T = Video Format, M = Maximum # of inputs, Q = Software version  
= CR/LF  
· = space  
! = Delimiter character = Indicates end of input selection character string.  
Characters also accepted as delimiters are: @ $ &  
= V value = (Model 8 = 1 - 8, Model 10 = 1 - 10)  
= T value = (1 = RGBS, 2 = RGsB, 3 = Composite, 4 = S-Video)  
= (8 if Model 8, 10 if Model 10)  
= 0.00 - 9.99  
ASCII/HEX: 0/30 1/31 2/32 3/33 4/34 5/35 6/36 7/37 8/38 9/39 !/26 E/45 i/69 I/49  
M/4D n/6E N/4E Q/51 T/54 V/56  
ASCII  
Command  
Response  
to Host  
Command  
Description; etc  
i
I
(Same as I Below)  
Information Request  
( V, T, M and Q defined above)  
V
·T ·M ·Q  
!
V
Switch to Channel  
n
N
(Same as N Below)  
Nxx-xxx-xx  
Request for Part Number  
xx-xxx-xx = Part number  
Possible Error Responses  
(See Below)  
(See Below)  
E01  
E10  
Invalid Channel Number  
Invalid Command Input  
Error Code Descriptions  
E01  
An attempt to select channel 0 or channels higher than the switcher's M value  
of 8 or 10 will cause an E01 error response.  
E10  
The delimiter character must be entered within three seconds of entering the  
channel number, otherwise an error type E10 response will be returned to the  
Host.  
Example Commands and Responses  
Command  
Response  
Description  
8!  
10!  
V8  
V10  
Select input channel 8  
Select input channel 10  
I
V2 T4 M8 Q1.23  
N60-095-01  
V2 = Input Channel 2  
T4 = S-Video Format  
M8 = 8 Inputs (Model 8 PLUS)  
Q1.23 = Software Version 1.23  
N
Part Number = 60-095-01  
Extron • Model 8 PLUS & Model 10 PLUS Switchers • User’s Manual  
Page 3-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Model 8/10 PLUS RS-232 Control  
Software  
The Model 8/10 PLUS Switcher control software is a program  
called UNIVSW. It is Windows® 3.1, 3.11 and Windows 95  
compatible and provides remote control of input selection.  
Installing the Software  
The program is contained on a single 3.5” diskette and will  
run from the floppy drive. However, it will be more convenient  
to load and run it from the hard drive. To install the software  
from the 3.5” floppy disk onto the hard drive, run SETUP.EXE  
from the floppy disk. The program will occupy approximately 1  
MB of hard drive space.  
The Windows installation will create (by default) a  
C:\UNIVSW directory and will place 2 icons (UNIVSW  
Program and UNIVSW Help) into a group or folder titled  
“Extron Electronics”.  
Using the Software  
1. For information about program features, double click on the  
UNIVSW Help ICON in the Extron Electronics group or folder.  
[Help can be accessed from its Icon (stand-alone) or from  
within the program by the Menu on the Main screen or by  
pressing F1 from any point within the program.]  
2. To run the software, double click on the UNIVSW Program  
ICON in the Extron Electronics group or folder.  
3. A Comm menu will be displayed on the screen. Click on the  
Comm Port that is connected to the Model 8/10 Switcher  
RS-232 port.  
4. The Extron UNIVersal SW Control Program window displays  
input selection (see picture below).  
Page 3-3  
Extron • Model 8 PLUS & Model 10 PLUS Switchers • User’s Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Model 8/10 PLUS RS-232 Control  
Model 10 PLUS Switcher w/PC RS-232 Control  
Extron • Model 8 PLUS & Model 10 PLUS Switchers • User’s Manual  
Page 3-4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Notes:  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Extron’s Model 8/10 PLUS Switchers  
User’s Manual  
Appendix A  
Configuring Features and Options  
Remote Connector  
KP-10 Remote Control  
IR-10 Remote Control  
Rack Mounting  
A
E
Download from Www.Somanuals.com. All Manuals Search And Download.  
Configuring Features and Options  
MANUAL REMOTE Connector  
The MANUAL REMOTE connector provides  
a way to control the Model 8/10 PLUS  
switchers using Extron or third party remote  
control devices.  
Extron Remote Control devices which are  
compatible with the Model 8/10 Switchers  
are the KP-10 and IR-10 which are covered  
on the following pages.  
MANUAL REMOTE connector pin  
assignments are shown in the table to the  
right. To select a different switcher input  
number through the remote connector,  
momentarily short the pin for the desired  
input number (#) to logic ground (pin 25).  
To force the switcher to select that input #  
continuously, leave the short to logic ground  
in place, this will override front panel input  
selection.  
The Tally pins can be used for remote  
indication of the switcher's selected input.  
Tally #1 - #10 (pins 14 - 23) will indicate the  
switcher's selected input # with a logic low  
(0 volts), the Tally pins are normally at logic  
high (5 volts).  
The schematics shown below may be used  
as a guide to design and build indicator  
circuits for the Tally pins. The +5 volt source  
on remote connector pin 13 is limited to  
100mA, if a different voltage or a higher  
current is required, an external voltage  
source will be necessary.  
RECOMMENDED RELAYS  
LED Indicator Circuit  
Incandescent Lamp Circuits  
MANUFACTURER  
GENERAL LOW CURRENT  
Aromat  
ITT/Panasonic  
Omron  
DS2  
R-Z-5C  
G5Y  
TQ  
A5W  
G6H  
EXTERNAL POWER  
Using an  
Opto-isolator  
& External Power  
RESISTOR VALUE  
DEPENDS ON CURRENT  
REQUIREMENT OF LAMP  
+5V (PIN 13)  
+5V (PIN 13)  
330 Ohm  
N/C  
LED  
+5V (PIN 13)  
Using a Relay  
& External  
Power  
1N916  
TALLY PIN  
330 Ohm  
TALLY PIN  
EXTERNAL POWER  
TALLY PIN  
Page A-1  
Extron • Model 8 PLUS & Model 10 PLUS Switchers • User’s Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Configuring Features and Options  
KP-10 Remote Control  
The optional EXTRON KP-10 hard wired remote controller  
consists of a keypad, a 25 foot cable and a 25 pin D male  
connector that connects to the MANUAL REMOTE connector  
on the rear panel of the switcher (see drawing below).  
With the KP-10 connected, all Model 8 PLUS and Model 10  
PLUS front panel operations can be duplicated using keys 0  
through 9 on the KP-10 keypad.  
The KP-10 operates in parallel with the front panel and the  
RS-232 port. The Model 8/10 PLUS Switchers can be  
controlled from any one of these three sources and no one  
source has priority over the other.  
The EXTRON part number for the KP-10 is 60-111-01.  
1
2
3
4
5
6
7
8
9
10  
Extron • Model 8 PLUS & Model 10 PLUS Switchers • User’s Manual  
Page A-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Configuring Features and Options  
IR-10 Infrared Remote Control  
The optional EXTRON IR-10 infrared (IR) remote control is a  
hand held unit. It communicates with the Model 8 PLUS and  
Model 10 PLUS switchers through an external IR detector that  
is connected to an adapter. The adapter connects to the  
MANUAL REMOTE connector on the switcher rear panel and  
gets its power from the +5 volts on pin 13.  
Operation requires pressing the key for the desired channel  
number while aiming the hand held unit at the IR detector.  
Approximate operating range is 30 feet.  
The IR detector receives infrared signals from the hand held  
IR-10 remote control and converts them to logic signals. The  
logic signals are used by the adapter to duplicate front panel  
channel selection.  
To install the IR-10 remote control system do the following:  
1. Power OFF the switcher.  
2. Connect the IR-10 adapter 25 pin plug to the MANUAL  
REMOTE connector on the rear panel of the switcher.  
3. Plug the RJ-11 male connector into the IR-10 Adapter  
RJ-11 female connector.  
4. Position the IR detector for the best reception of the  
infrared light from the IR-10 hand held remote controller  
(limited by a 6' cable).  
5. Power the switcher ON.  
The EXTRON part number for the IR-10 is 70-036-01.  
1
2
3
4
5
6
7
8
9
10  
Model 10 PLUS Switcher  
Page A-3  
Extron • Model 8 PLUS & Model 10 PLUS Switchers • User’s Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Configuring Features and Options  
Rack Mounting  
The Model 8 PLUS and Model 10 PLUS switchers can be  
rack-mounted using an optional 19" 2U Universal Rack Shelf,  
one switcher per shelf. The Extron Part Number for the  
Universal Rack Shelf is 60-032-01.  
The installation procedure follows.  
10-32 x 3/4  
Screws  
#10 Beveled  
Washers  
Use two screws to secure switcher to shelf  
Installing the 2U Shelf in a Rack  
Use the four 10-32 x 3/4 black screws and #10 black beveled  
washers to mount the 2U Shelf in the Rack.  
Installing the Model 8/10 PLUS Switcher on the Shelf  
The 2U Universal Rack Shelf is designed to enable the Model  
8 PLUS or Model 10 PLUS Switcher to set on the shelf with  
the switcher's four feet extending through four holes. It is not  
necessary to attach the switcher to the shelf with screws.  
Upon completion of this procedure, return to the Installation  
Guide in Chapter 2 and continue with the next step in the  
procedure.  
Extron • Model 8 PLUS & Model 10 PLUS Switchers • User’s Manual  
Page A-4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Accessories/Part Numbers  
Model 8 PLUS Switcher .............................................. 60-094-01  
Model 10 PLUS Switcher ............................................ 60-095-01  
Model 8/10 PLUS User's Manual ................................ 68-080-01  
Universal Rack Shelf, 19" 2U...................................... 60-032-01C  
KP-10 Remote Control ................................................ 60-111-01  
IR-10 Remote Control ................................................. 70-036-01  
S-VHS-BNC Adapter ................................................... 26-353-01  
BNC-4 HR Cable  
BNC-4-3’HR (3 feet/0.9 meters) ................................. 26-210-01  
BNC-4-6’HR (6 feet/1.8 meters) ................................. 26-210-02  
BNC-4-12’HR (12 feet/3.6 meters) ............................. 26-210-03  
BNC-4-25’HR (25 feet/7.5 meters) ............................. 26-210-04  
BNC-4-50’HR (50 feet/15.0 meters) ........................... 26-210-05  
BNC-4-75’HR (75 feet/23.0 meters) ........................... 26-210-06  
BNC-4-100’HR (100 feet/30.0 meters) ....................... 26-210-07  
BNC-4-150’HR (150 feet/45.0 meters) ....................... 26-210-08  
BNC-4-200’HR (200 feet/60.0 meters) ....................... 26-210-09  
BNC-4-250’HR (250 feet/75.0 meters) ....................... 26-210-54  
BNC-4-300’HR (300 feet/90.0 meters) ....................... 26-210-53  
BNC-4 Mini-HR Bulk (300’/90m up to 5000’/1500m).. 22-073-01  
Page A-5  
Extron • Model 8 PLUS & Model 10 PLUS Switchers • User’s Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Eiki Projector EIKI LC SVGA860 User Manual
Eiki Projector LC 4300 User Manual
Escort Radar Detector ZR3 User Manual
Eureka Vacuum Cleaner 400 409 User Manual
Fisher Price Model Vehicle 74527 User Manual
Fujitsu Printer FTP 641MCL101 102 User Manual
Fujitsu Scanner S500M User Manual
GE Iron 169173 User Manual
GE Microwave Oven SCA2000BCC User Manual
Gigabyte Computer Accessories GA 7vkml User Manual