| 	
		 2. Fasten the power output cord to the ZipClip base.   
					Extron External Power Supply •   
					a. Insert tie wraps (“zip ties”) along the notches on the side of the   
					Installation Guide   
					power supply and   
					through the tie wrap   
					anchor points on the   
					ZipClip, then around   
					the cord.   
					Important Safety Instructions   
					This symbol is intended to alert the user of impor-   
					tant operating and maintenance (servicing) instruc-   
					tions in the literature provided with the equipment.   
					WARNING: To reduce the risk of fire or electric shock, do not   
					expose this apparatus to rain or moisture.   
					This apparatus shall not be exposed to dripping or splashing   
					and no objects filled with liquids, such as vases shall be   
					placed on the apparatus.   
					Cable   
					Strain   
					Relief   
					b. Connect and pull the   
					This symbol is intended to alert the user of the   
					presence of uninsulated dangerous voltage within   
					the product enclosure that may present a risk of   
					electric shock. On the product, risk of shock may   
					be indicated by this symbol.   
					tie wraps until they   
					Tie Wrap   
					Refer all servicing to qualified service personnel. Servicing is required   
					when the apparatus has been damaged in any way, such as   
					when the power-supply cord or plug is damaged, liquid has   
					been spilled or objects have fallen into the apparatus, the   
					apparatus has been exposed to rain or moisture, does not   
					operate normally, or has been dropped.   
					are secure. Do not   
					over tighten.   
					Read these instructions.   
					Keep these instructions.   
					Heed all warnings.   
					Follow all instructions.   
					Mounting   
					WARNING: This apparatus is a Class I product. This product   
					must be connected to a MAINS socket outlet with a   
					protective earthing connection.   
					Do not use this apparatus near water.   
					Clean only with dry cloth.   
					Do not block any ventilation openings. Install in accordance with the   
					manufacturer’s instructions.   
					CAUTION: These power supplies are not suitable for use in air handling   
					spaces or in wall cavities. The power supply is to be located within   
					the vicinity of the Extron AV equipment in an ordinary location   
					with IEC 1010 pollution degree 2, and secured to an equipment rack   
					within a dedicated closet, podium, or desk.   
					The mains plug is used as the disconnect device and shall remain   
					readily operable.   
					Do not install near any heat sources such as radiators, heat registers,   
					stoves, or other apparatus (including amplifiers) that produce heat.   
					To prevent the risk of shock, do not attempt to service this   
					equipment yourself because opening or removing covers may   
					expose you to dangerous voltage or other hazards.   
					Do not defeat the safety purpose of the polarized or grounding-type   
					plug. A polarized plug has two blades with one wider than   
					the other. A grounding type plug has two blades and a third   
					grounding prong. The wide blade or the third prong are provided   
					for your safety. If the provided plug does not fit into your outlet,   
					consult an electrician for replacement of the obsolete outlet.   
					WARNING:   
					Power sources • This equipment should be operated only from   
					the power source indicated on the product. This equipment   
					is intended to be used with a main power system with a   
					grounded (neutral) conductor. The third (grounding) pin is   
					a safety feature, do not attempt to bypass or disable it.   
					The installation must be in accordance with the applicable provisions   
					of National Electrical Code ANSI/NFPA 70, article 75 and Canadian   
					Electrical Code part 1, section 16. The power supply shall not be   
					permanently fixed to building or similar structure.   
					Protect the power cord from being walked on or pinched particularly at   
					plugs, convenience receptacles, and the point where they exit from   
					the apparatus.   
					Only use attachments/accessories specified by the manufacturer.   
					Power disconnection • To remove power from the equipment   
					safely, remove all power cords from the rear of the   
					equipment, or the desktop power module (if detachable), or   
					from the power source receptacle (wall plug).   
					Unplug this device apparatus during lightning storms or when   
					unused for long periods of time.   
					Rack Mounting   
					Mounting to a Rack Shelf   
					About the Extron PS 910, PS 1210, PS 1508   
					Power Supplies   
					These power supplies are one eighth rack wide. Up to eight power supplies   
					can be mounted side by side directly onto a rack shelf.   
					1. Align the threaded holes in the bottom of the power supply with the   
					Model Overview   
					holes in an Extron rack   
					shelf and fasten the   
					supply to the shelf   
					with two 4-40 x 3/16"   
					screws as shown   
					below.   
					Model   
					Power Output   
					9 watts, 9 VDC, 1 A   
					9 watts, 9 VDC, 1 A   
					12 watts, 12 VDC, 1 A   
					12 watts, 12 VDC, 1 A   
					12 watts, 15 VDC, 0.8 A   
					— 
					Termination   
					Captive screw   
					DC plug   
					PS 910C   
					PS 910P   
					PS 1210C   
					PS 1210P   
					PS 1508C   
					Captive screw   
					DC plug   
					Captive screw   
					— 
					ZipClip™ 100   
					b 
					(101-002-01)   
					RSB 123   
					Rack Shelf   
					Cabling and Features   
					Features   
					a 
					(2) 4-40 x 3/16"   
					Screws   
					Notches for   
					Securing   
					Tie Wrap   
					AC   
					Power   
					Input   
					2. Bolt the rack shelf to the rack.   
					Power   
					LED   
					z 
					X 
					1MA   
					124V5-60H   
					Mounting to Rack Rails Using a ZipClip   
					ZipClip   
					Mounting Slot   
					(front and rear)   
					1. Fasten the ZipClip 100   
					mounting clip to a   
					rack rail using   
					two rack   
					DC Power   
					Output   
					Connector Pin Assignments   
					screws as   
					shown in the   
					PS 910C, PS 1210C, PS 1508C   
					PS 910P, PS 1210P   
					Tie Wrap   
					Smooth   
					diagram at   
					ZipClip 100   
					right.   
					Tip (+)   
					Power Supply   
					Output Cord   
					Captive Screw   
					Connector   
					Ridged   
					Sleeve (   
					-)   
					Side of Rack   
					Alternative Wiring Option   
					Smooth   
					2. Insert the   
					power supply   
					into the ZipClip as   
					described previously   
					and press to snap it   
					into place.   
					Power Supply   
					N/C   
					Back of   
					Rack   
					Output Cord   
					Ridged   
					Inside   
					Rack   
					Using the ZipClip 100   
					Attaching and Removing the Clip and Power Supply   
					To attach the power supply to the ZipClip 100 mounting clip:   
					Pole or Table Leg Mounting   
					1. Insert the bottom of the power supply down into the clip,   
					starting with one end.   
					1. Wrap a tie wrap around   
					the projector mount pole or table   
					leg and the power supply at one of   
					the tie wrap notches, and fasten the   
					2. Pivot the other end down and press until the clip snaps into place.   
					tie wrap together to secure the   
					power supply to the pole or table   
					leg.   
					To remove the power supply from the ZipClip:   
					Tie Wrap   
					to Pole   
					b 
					1. Press the tab on the ZipClip.   
					2. Pivot the power supply and lift it out   
					2. Repeat step 1 at the other tie wrap   
					of the ZipClip.   
					notch.   
					Using Tie Wraps for Cable Strain Relief   
					1. Attach the power supply to the ZipClip mounting clip as described   
					See the next page for   
					furniture mounting instructions.   
					previously.   
					1 
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				 |