The Extron VNR 100 recorder is a network storage device capable of recording and playing back PURE3 video, audio, and  
data streams from VN‑Matrix codecs and encoders in a VN‑Matrix system. The system must be under the control of an Extron  
VNM Enterprise Controller.  
This guide provides basic instructions for an experienced installer to configure and operate a VNR 100 recorder.  
NOTE: For complete instructions about mounting, installation, and network configuration, see the VNR 100 User Guide and  
the VNM Enterprise Controller User Guide at www.extron.com.  
TouchLink Touchpanel  
External User Control  
VN-Matrix  
VNR 100  
Recorder  
VNR 100 Recorder  
Browser Based User  
Control  
VN-Matrix  
Network  
VNR 100  
Recorder  
Multicast Enabled  
Network  
VNR 100 Recorder  
VNM Enterprise Controller  
LAN-1  
LAN-2  
STATUS  
LAN-1  
LAN-2  
STATUS  
VN-MATRIX 225 SERIES  
RGB/DVI OVER IP  
VN-MATRIX 225 SERIES  
RGB/DVI OVER IP  
LAN-1  
LAN-2  
STATUS  
LAN-1  
LAN-2  
STATUS  
VN-MATRIX 225 SERIES  
RGB/DVI OVER IP  
VN-MATRIX 225 SERIES  
RGB/DVI OVER IP  
LAN-1  
LAN-2  
STATUS  
LAN-1  
LAN-2  
STATUS  
VN-MATRIX 225 SERIES  
RGB/DVI OVER IP  
VN-MATRIX 225 SERIES  
RGB/DVI OVER IP  
Multiple VNM 200 and 225 Series Encoders  
(or CODECs configured as encoders)  
Multiple VNM 200 and 225 Series Decoders  
(or CODECs configured as decoders)  
Installation  
1. Mount the VNR 100 using the provided rack mount kit (see Mounting, below).  
2. Connect a standard IEC power cord to the rear panel connector (see Rear Panel Features on page 2).  
3. Connect the VNR 100 to the same network as the VNM Enterprise Controller, using Ethernet port 0 (see Rear Panel Features  
on page 2).  
4. Power on the VNR 100 (see VNR 100 Power Up Procedure on page 3).  
5. Use a computer on the same network to carry out the initial configuration (see VNR 100 Initial Configuration on page 3).  
6. Use the VNM Enterprise Controller to configure the VNR 100 (see Getting Started with the VNM Enterprise Controller on  
page 4).  
7. If it becomes necessary to power down the VNR 100, see VNR 100 Power Down Procedure on page 3.  
Mounting  
The VNR 100 can be mounted in a rack, using the provided kit. See the VNR 100 User Guide at www.extron.com for UL  
guidelines for rack mounting and complete mounting instructions.  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Status LEDs — five LEDs providing information about:  
e
2
1
i
Overtemperature  
Network  
Activity (2)  
Network  
Activity (1)  
Drive  
Activity  
Power  
a. The Overtemperature LED flashes yellow when a fan fails. It lights yellow solidly when the internal temperature is too high  
(this may be caused by high ambient temperature or a fan that is obstructed).  
b. Network 2 is not active, so this LED does not light.  
c. The Network Activity (1) LED flashes green when there is activity on Network 1.  
d. The Drive Activity LED flashes yellow when the hard drive is in use.  
e. The Power LED lights green when the unit is receiving power.  
Reset button — is used to reboot the VNR 100.  
f
g
Power button — used to apply or turn off the main power. When main power is turned off, standby power is actively  
supplied to the recorder.  
OS drive — houses the solid state operating system drive (removable).  
Media drive — houses the media drive (removable).  
h
i
j
Spare drive bays (2) — are not used. They must not have drives fitted.  
ATTENTION:  
Do not remove the OS drive or media drive while the VNR 100 is powered on.  
For complete instructions about replacing the OS drive, see the VNR 100 O/S Drive Replacement Kit Installation  
Guide at www.extron.com.  
For complete instructions about replacing the media drive, see the VNR 100 Media Drive Replacement Kit  
Installation Guide at www.extron.com.  
VNR 100 Power Up Procedure  
NOTE: Before powering up the VNR 100, ensure all necessary devices are connected correctly and powered up.  
Power up the VNR 100 by pressing the power button (see Front Panel Features figure, ). The VNR 100 boots up.  
g
VNR 100 Power Down Procedure  
Power down the VNR 100 by pressing and releasing the power button (see Front Panel Features figure, ). Ther recorder takes  
g
approximately 20 ‑ 30 seconds to power down.  
VNR 100 Initial Configuration  
Network Considerations  
Before connecting the VNR 100 recorder to the network, you need to know the network settings of both the VNR 100 and the  
VNM Enterprise Controller. The following are the default settings. Check with your network administrator to be sure they still apply  
to your unit:  
Network settings (ETH0)  
IP address  
192.168.254.254  
255.255.255.0  
Subnet mask  
Gateway address 192.168.254.253  
Port  
8080  
Controller  
IP address  
Port  
192.168.254.254  
5432  
Configuration  
User name  
Password  
config  
config  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
VNR 100 • Setup Guide (Continued)  
1. Use a computer connected to the same network as the VNR 100. In the browser address bar,  
enter the IP address of the recorder, followed by a colon (:) and the port number. By default, this  
is 192.168.254.254:8080. Contact your network administrator to be sure these values have  
not changed.  
The login screen opens (see figure at right).  
2. Enter the Usernameand Password.  
NOTE: By default, both the Usernameand Passwordare config.  
3. Click Login. The VNR 100 Recorder Settings page opens (see figure at right).  
4. Enter the IPAddress, SubnetMask, and GatewayAddressof the recorder.  
Logout  
5. Enter the ControllerIPaddress, Controllerportnumber and maximum transmission  
unit (MTU) setting for the controller. Contact your network administrator to ensure you have  
the correct values.  
VNMatrix recorder settings  
Network settings [eth0]  
192.168.254.254  
IP Address  
Subnet Mask  
Gateway  
255.255.255.0  
192.168.254.253  
Recorder settings  
1111999  
ATTENTION: The VNM Enterprise Controller port number is used by all VN‑Matrix  
devices to communicate with the VNM Enterprise Controller. The value should  
only be changed if the VNM Enterprise Controller has been configured to accept  
communications on a different port number.  
Serial  
Controller IP  
Controller port  
192.168.254.254  
5432  
MTU  
1500  
User settings  
New password  
Confirm New password  
Data disk  
Under normal circumstances, the setting should remain at the default value (5432).  
Umount  
status:  
mounted to /home/matrix_rec/Recording_Files  
19GB->98% used  
Disk free space:  
Format  
formated to ext3  
6. Enter a New passwordand Confirm New password.  
Apply Changes  
Cancel Changes  
7. Click Apply Changesto save the settings (or Cancel Changesto exit without saving the  
information).  
Getting Started with VNM Enterprise Controller  
The VNM Enterprise Controller must be on the same network as the VNR 100.  
1. Use a PC on the same network as the controller to access the controller website. In  
the browser address bar, enter the controller IP address. The Login screen opens (see  
figure at right).  
2. Enter the Usernameand Password.  
NOTE: By default, for the VNM Enterprise  
Controller, the Usernameis admin. Leave  
the Passwordblank (no entry is required).  
3. Click Login. The Enterprise Controller device list  
opens (see the figure to the right).  
4. Check the box next to the VNR 100 recorder. A  
series of action buttons appear at the bottom of  
the screen (see figure below).  
See the Enterprise Controller User Guide (at  
www.extron.com) for complete information  
about configuring and using the VNR 100.  
Extron Asia  
Extron India  
Extron Headquarters  
Extron Europe  
Extron Japan  
Extron China  
Extron Middle East  
Extron Korea  
+65.6383.4400  
+65.6383.4664 FAX  
1800.3070.3777  
Inside India Only  
+1.800.633.9876 (Inside USA/Canada Only)  
+800.3987.6673  
(Inside Europe Only)  
+81.3.3511.7655  
+81.3.3511.7656 FAX  
+86.21.3760.1568  
+86.21.3760.1566 FAX  
+971.4.299.1800  
+971.4.299.1880 FAX  
+82.2.3444.1571  
+82.2.3444.1575 FAX  
Extron USA - West  
+1.714.491.1500  
Extron USA - East  
+1.919.850.1000  
+91.80.3055.3777  
+31.33.453.4040  
+91.80.3055.3737 FAX  
+1.714.491.1517 FAX  
+1.919.850.1001 FAX  
+31.33.453.4050 FAX  
68-2237-50 Rev. A  
© 2013 Extron Electronics All rights reserved. www.extron.com  
05 13  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
   

Eagle Electronics Fish Finder Fish ID II User Manual
Eicon Networks Network Card C2x Family User Manual
Electro Voice Portable Speaker Force 10 User Manual
Euro Pro Iron GI468H User Manual
Fisher Price Baby Walker 79070 User Manual
Flymo Lawn Mower Turbo 400 User Manual
Frigidaire Microwave Oven FGMC3065KB User Manual
GE Freezer FUM12SM User Manual
Generac Power Systems Portable Generator QT04524 User Manual
Globe Mixer SP8 User Manual